=============================================================================== Emulex 16GB FC Firmware Package ===============================================================================
Firmware Version: 10.4.303.3 Supported On: System x Rack
Problems Fixed: - VF speed is showing wrongly in ethtool and Ocm. - Firmware download using ethtool -f command is failing with opcode 172-1 failed:status 100-208 - Can not set the DelayDeviceDiscovery to Max (255) by ASU tool - Ports intermittently logging in to Brocade switch as G-Port
Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Problems Fixed: - Blue screen after firmware flash to with virtualized WWPN
Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Incremental Interoperability: - Grantley based ITE
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 10.2.377.18 Supported On: System x
Problems Fixed: - Link does not recover during IO + Port Cycling with FW 1.1.43.3 - BIOS versions return multiple values - LPe16k point to point (direct attached) connection not bootable in legacy BIOS - LPe16k point to point (direct attached) connection performance issues in legacy BIOS
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex
Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change - Reported firwmare version in CMM is intermittently incorrect - Unable to set pause Flow control when connected to DCBX switch with PFC off - during cable pull testing a 40 second delay in link up experienced with Brocade switch ports - I/O completion and abort completion WQE are generated out of order - Unexpected WCQE in RQ CQ seen in RXRI mode while performing cable pulls
Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console) - Crosslink & Express Lane on LPe16k based solutions
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 1.1.43.21 Supported On: IBM System x
Incremental Interoperability: - None
Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu
Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x
Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup
Firmware Version: 1.1.21.9 Supported On: IBM System x
Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics
Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches
- Fixed SMP passthrough command failure due to smp back off interrupt. Appears in system log as 0x311c0030. (SCGCQ00889925) - Fixed issue where host boot fails in the presence of blank flash/corrupt firmware in flash (SCGCQ00894439) - Fixed issue where SATA drive errors, bad performance, or boot failure may appear after update to 20.00.02.00 firmware (SCGCQ00859226)(Retain Tip# H015210)
Version 1.20.01 - Moderate Impact/Low Probablility of Occurrence ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.03.00 7.27.04.00
- Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
- Fixed issue where acceptable indistro device drivers may not pass minium driver check. BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal. - Fixed issue where update will not install with the 09.101 megaraid_sas device driver.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
Version 12.15.0-0248 - Moderate Impact/Low Probability of Occurrence --------------------- MR Firmware: 2.130.403-6221, BIOS: 3.30.02.2_4.16.08.00_0x06060A05007/23/2014 , HII: 03.07.12.04,
Fixes: - Fixed an issue where CLI command set securitykey=Lsi@12345" failed with error code "1001" and error message "invalid key". (SCGCQ00553069) - Fixed an issue where drive speed in WebBIOS was showing as unknown. (SCGCQ00751036) - Fixed an issue where WebBIOS and MSM were displaying different sizes for total capacity property for the same drive group. (SCGCQ00752176) - Fixed an issue where foreign configuration holding data structure was getting corrupted while importing number of vds greater than the supported count of 31. (SCGCQ00931011 Port of Defect SCGCQ00927528) - Fixed an issue where Firmware hits assertion while booting with 4K PDs. (SCGCQ00944388 Port of Defect SCGCQ00927547)
Enhancement(s): - Changed the battery status text in BIOS from "missing" to "N/A" for iMR solutions. (SCGCQ00690943)
Version 12.15.0-0240 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Fixed issue where JBOD mode would be disabled and would not boot to JBOD drive if one of the VDs is offline (SCGCQ00827731) - Fixed illegal request sense messages seen repeatedly in FW logs. (SCGCQ00898459) - Fixed system hangs that could occur due to recoverable errors being marked as unrecoverable (SCGCQ00923692)
Version 12.15.0-0226 -------------------- - Fixed an issue where JBOD drives were not reporting the correct drive temperature (SCGCQ00831639) - Corrected LED behaviour for IBM 6Gb SAS Expander Backplane (SCGCQ00754433)
Version 12.15.0-0199 - Critical ------------------- Enhancement: - Display drive speed for 12 GB Seagate hard drives in MSM. - List battery status in BIOS as N/A for iMR controllers Fixes: - Fixed incompatibility issue with System x3200/3250 M3 causing hang condition (RETAIN Tip H211826) - Fixed an issue where self-encrypting (SED) hard disk password fails to allow access to virtual disk configurations - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where WebBIOS is not displaying correct index position for boot error handling option. - Fixed an issue where WebBIOS advanced software option locks the server.
Version 12.13.0-0179 - Critical ------------------- Enhancement: - Implemented limited band charging for iBBU08. (RETAIN tip H21631) - CacheCade 2.0 read and write caching on SSDs is supported on ServeRAID M5014 and ServeRAID M5015 with the ServeRAID M5000 Series Performance Accelerator Key. Fixes - Fixed an issue in multipath topology to use an alternate IO path if the current active path is removed. - Fixed an issue where drive states were marked as online before the creation of recontruction volumes completed. - Resolved controller hang condition during system bootup. - Fixed issue causing iBBU07 to always show "Charging" state (RETAIN tip H211025) - Fixed issue causing Virtual Disks to remain in Write-Through state after a relearn (RETAIN tip H211101) - Addressed data exposure issue when using CacheCade
Version 12.12.0-0133 - Suggested ------------------- Fixes: - Addressed an issue where battery over temperature messages could occur during charging. - Fixed issue in the HII broswer where the drive performing copyback will be stated as replacing and not copyback. - Fixed issue in the HII browser where the RPM for SATA drives show "0" - Fixed issue in HII browers where port 4 is shown on both ports 0 and 1 - Fixed HII browser issue where the user will get an error message when a global hot spare is created. - Fix HII browser issue where a RAID volume with greater then 3 spans will fail to create.
Version 12.12.0-0126 - Critical ------------------- Fixes: - Fixed a issue where the RAID configuration can be lost when updating from firmware package 12.0.1-0097 or below. - Fixed an issue with 4-kilobyte (KB) sector disk support compatibility in NTFS by disabling 512E drive support mode.
Version 12.12.0-0111 - Suggested ------------------- Enhancement: - Support for 512e and 4k SAS/SATA hard drives added - Implemented limited band charging for iBBU 07. - CacheCade 2.0 read and write caching on SSDs is supported on ServeRAID M5014 and ServeRAID M5015 with the ServeRAID M5000 Series Performance Accelerator Key. Fixes: - Set the compatibility bit to 1 so that Patrol reads can be executed on SSD's - Fixed an issue where EEPROM init failures are not handled properly causing the user to see the following message on POST "The native configuration is no longer supported by the current controller and firmware." - Fixed an issue where the controller fails to read the header info from CFI Flash ROM. - Resolved issue switching to WT mode for recently failed batteries.
Version 12.12.0-0098 - Suggested ------------------- Fixes: - Fixed issue where the battery gauge is not accurate for aged batteries due to the discharge profiles of aged batteries not matching that of the new batteries. - Fixed a issue where a reboot would cause a hot spare to revert to 'Unconfigured Good' state when Performance Accelerator Key is attached. (RETAIN Tip H204925)
Version 12.12.0-0085 - Suggested ------------------- Enhancements: - Prevent non IBM firmware from being flashed on IBM ServeRAID branded controllers. - Enabled iBBU08 battery modes. - ibbu battery will no longer be marked as bad when very high capacity is detected. - Dimmer Switch function has been disabled by default.
Fixes: - Fixed a issue where firmware was taking to long to complete the PCI config read, causing the system to generate an NMI. - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Removed BBU mode select from Web BIOS for all controllers. - Fixed issue where pulling VD 0 from a R60 and rebooting would cause two foreign configurations. - Fixed issue where WebBIOS gives unclear message when enabling FDE on an existing Disk Group. - Fixed issue where iBBU07 batteries display 65K capacity and are marked SOH bad. - Fixed issue where iBBU Absolute Charge is displayed differently - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the controller cannot sustain at least 950 MBps performance with Cache Flush setting one sec. - Fixed issue where the set properties command fails - Fixed issue where the iBBU07 battery reported remaining capacity is much too high (64751 mAh) after a learn cycle. - Fixed issue where extended retries of write verify commands cause a driver timeout. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed a issue where an alert should be sent when one phy connector between the SAS controller and SAS expander is degraded. - Enabled puncturing for SATA drives. - Enabled copy back on SMART. - Fixed an intermittent RAID key failure during power-on. - Fixed firmware issue where firmware would cause the controller to (sles11sp1/rhel6) reset when ‘lspci –vvx’ command is executed. - Change for iBBU-08 to support firmware Mode5 WB capacity from 960mAh to 674mAh for low power DDR-2 - Fixed a issue where the iBBU battery will not charge while the server continually resets causing the iBBU battery to over-charge.
Version 12.12.0-0065 - Critical ------------------- Fixes: - Fixed issue where the firmware takes too long to complete a PCI Config Read cycle causing SLES11 to kernel panic. - Fixed issue where MegaCLI may not be able to change drive or controller cache setting resulting in a return code of 0x03. - Added check to return SCSI sense Check condition if PMI is set and LBA is non Zero for SCSI Read Cap 16 - Fixed issue where a blue screen occurs handling RAID 1 with HSP and medium errors. The blue screen occurs because the driver times out while the firmware is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Change the boot with pinned cache RAID level support which was only allowed for raid level 0. The check is removed and is allowed for any raid level. - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early - Remove the following message "Battery cannot initiate transparent learn cycles" when the iBBU08 is under mode 4 or 5 - Fixed issue where BGI will not disable when a user issues megacli -LDBI -Dsbl -L0 -a0
Version 12.12.0-0056 - Critical ------------------- Fixes - Fixed issue where multi-bit ECC's are not reported during POST - Lowered the capacity level at which event notifications are generated for early warning and end of life alerts for iBBU to equal 48 hours
Version 12.12.0-0047 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users from downleveling firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur - Fixed issue where a remote iBBU08 will not be seen by the controller - Fixed data issue When IO is in progress to a RAID 1 array that contains media errors and is under a rebuild - Fixed issue where a drive is not marked as foreign during a drive move between servers causing the import of the configuration to fail - Fixed issue where the uEFI WebBIOS does not accept the + symbol in the key code or pass phrase - Fixed issue for iBBU08
Enhancement: - Enhancement to Reserve/release call for VCS Symantec configurations - Enhancements to iBBU event notifications, including the addition of early warning message. - Raised the capacity level at which event notifications are generated for early warning and end of life alerts for iBBUs.
Version 12.12.0-0039 - Critical ------------------- Fixes: - Fixed intermittent initialization failure during POST with the ServeRAID M5025, M5015, and M5014 where the RAID BIOS could fail to load or the user will see one of the following error messages on POST:
RAID Adapter Unrecoverable Error!!! Please check the SDRAM connection.
or
Multi-bit ECC errors were detected on the RAID controller
Version 12.12.0-0037 - Critical ------------------- Enhancement: - Add support for iBBU08 (Battery Backup)
Fixes: - Addressed data issue while reconstructing from RAID1 to RAID0. - Addressed data issue after power lose to ServeRAID controllers. - Addressed data issue in some database applications. - Added fixes from LSI channel products.
Version 12.7.0-0020 - Critical ------------------- Enhancement: - Initial release for ServeRAID M5025 SAS/SATA Controller (46M0830)
Fixes: - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed issue where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 12.0.1-0097 - Critical ------------------- Fixes: - Addresses an issue where data becomes inaccessible when drive is secured after data has been written . Version 12.0.1-0096 - Critical ------------------- Fixes: - Fixed an issue where the BBU may not be seen on POST. - Fixed an issue where the firmware doesn't follow the spinupdelay and maxtargetspinup values set in NVDATA causing spin up of all the drives a at the same time. - Fixed a very intermittent issue where the RAID key (M5000) authentication may not occur on boot leaving users without key options. - Addressed a very rare issue with the expander devices where the firmware megamon could occur if the sgpio configuration cable has errors.
Version 12.0.1-0090 - critical ------------------- Fixes: - Fixed issue where controller properties such as Rebuild, CC, and BGI are not changing when up and down arrow keys are used. - Fixed issue on x3950 M3 servers that can cause a system hang at reboot
Version 12.0.1-0084 - Non-critical ------------------- Enhancement: - Support added for the ServeRAID M5000 Series Advanced Feature Key.
Version 12.0.1-0064 ------------------- - Initial release ibm_fw_sraidmr_m5000-12_15_0-0248_windows_32-64_chg
=============================================================================== Emulex FC Device Driver for Windows ===============================================================================
Device Driver Version: 10.4.246.0 Supported On: System x Rack
Problems Fixed: - System crashes when running a diagnostic Quick test on a disabled port if port hasn't been reset yet
Incremental Interoperability - Improved debug capability in driver logging - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.261.4 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - ABTS sent by tape device ignored by HBA - BSOD issue during CPU Hot replace test - XE102/XE104 - OCManager reports link down on both ports
Incremental Interoperability: - Crosslink & Express Lane on LPe16k based solutions
Device Driver Version: 10.0.720.0 Supported On: IBM System x
Problems Fixed: - Concurrent Hardware and Operating System (CHAOS) Test fails in XE-10x 10G - Extloopback command not supported with LPe16000 adapters with 16Gb link speed - Windows FC driver bug with Data Domain virtual tape library
Device Driver Version: 2.74.016.001 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Cleaned up a variety of corner case issues to avoid BSODs - Fixed IOCTL encounter bug-chk on BE3 during NPIV tests - Fixed reporting incorrect error code when creating vport on a switch without NPIV supported - Updated the default model name for 16G HBAs
Device Driver version: 2.74.009.001 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Clean up non-critical legacy FC and uCNA incompatibilities - LUN masking doesn't persist after reboot - Emulex GUI crashes when closing a running Upgrade utility and re-open it in 802.3 configuration with IP or MAC - Several bugs related to creation or deletion of vports
Incremental Interoperability: - Windows 2012 - Improved debug capabilities - Tighter integration with MS Windows Design Kit
Device Driver Version: 2.70.018 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Fixed sending ABTS continuously to Flogi issue - Fixed reset and link bounce issues for SLI4 FC public loop - Added support for ABTS timeout handling for both SLI3 and SLI4 - Fixed loopback test incorrectly dropping the loopback frame in SLI4 - Fixed exchange management issue in SLI4 CT receive path causing array overflow - Fixed firmware version update issue following download in link up state - Fixed problem in init_vfi completion handler that stalled fabric login on BE FCoE FW - Fixed problem that caused OCM ELS Echo Test to fail - Fixed the loopback test issue in recovering from error condition - Add persistent link down support for SLI4 FC - Fix DFC_IssueDumpMBox to manage request type 3 which includes link select option - Modified reinitialization sequence following reset to fix discovery failure post type 1 or type 3 reset - Fixed new firmware dump issue
ServeRAID M and MR10 Series SAS Controller Driver for Windows Server 2016/2012R2/2012
Adapters Supported: ServeRAID M1215 SAS/SATA Controller for IBM System x (46C9114) ServeRAID M1210e SAS/SATA Controller ServeRAID M5210e SAS/SATA Controller for IBM System x ServeRAID M5210e SAS/SATA Controller ServeRAID M5115 SAS/SATA Controller for IBM Flex System (90Y4390) ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) ServeRAID M5016 SAS/SATA Controller (90Y4304) ServeRAID M5015 SAS/SATA Controller (46M0829) ServeRAID M5014 SAS/SATA Controller (46M0916) ServeRAID M5025 SAS/SATA Controller (46M0830) ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
NOTE TO SERVICE - Reference RETAIN TIP #NA
Version 6.714.15.00 - Moderate Impact/Low Probability of Occurrence --------------------- Defects (8) - Controller name not updated for Double Raid in inf file.(SCGCQ01716605) - Customer specific references appearing in release notes ROP MR_WINDOWS_DRIVER_6.14-6.714.12.00-SCGCQ01698179.(SCGCQ01710907) - Code Review Defect : To divert FPIOs with chain frame to FW path.(SCGCQ01616582) - Driver signing script needs to change to be compatible with new certificate from Symantec.(SCGCQ01418985) - 6.14 : Windows Read me File is not adhered to OS Matrix Policy.(SCGCQ01427717) - Hercules Driver: Windows Driver read me has to remove non-relavant references for HPE.(SCGCQ01393370) - When compared the inf file with previous release observing older entries are removed in recent RO.(SCGCQ01853306) - MonTask Event in fwlog, system restart/hibernation during OCR..(SCGCQ01399666) - BSOD when running standard IO.(SCGCQ01870260 port of SCGCQ01850715) - Add support for OEM Invader MR controllers.(SCGCQ01746601 port of SCGCQ01197420) - [Lenovo] Request to add NVDATA and PNP IDs for new card introduction - "Rambler 8i 4GB".(SCGCQ01837658 port of SCGCQ01727447) - MR7.8-9480-8i8E: Hit BSOD After creating Raid 5 With 21 drives.(SCGCQ01873519 port of SCGCQ01867931) - Activate Control Flow Guard in Driver Build.(SCGCQ01599533 port of SCGCQ01592449) - Lost controller after OCR when triggering taskmgmt from Jammer.(SCGCQ01462845 port of SCGCQ01447394) - MR_6.13 : Windows Driver fails to discover Shannon 2G board in JBOD mode.(SCGCQ01414629 port of SCGCQ01218422)
EnhancementRequests (11) - [Lenovo ThinkServer] Request to add NVDATA and PNP IDs for new card introduction - "Streetfighter 8i 2GB".(SCGCQ01825026) - Sync the INF File across MR 6.x streams..(SCGCQ01849668) - OEM requesting addition of PNP ID for a new controller.(SCGCQ01870719) - Sync the HPE Stream ofMR 6.14 into MR 6.14 Point Mainline.(SCGCQ01597915) - Sync the MR 6.14 Dev and Point Stream.(SCGCQ01873541) - Add OEM PNP IDs for JBOD Mode for MR 6.14 Patch Release.(SCGCQ01391046) -.(SCGCQ01447001) - Roll back MCTP changes from MR 6.14 driver.(SCGCQ01764883) - Add OEM PNP ID for Intruder.(SCGCQ01404737) - Divert FastPath IO with Chain frame to Firmware.(SCGCQ01594170) - WS2016 DCHU Compliance for SAS3 MR6.15 and Phase 16, and SAS3.5 MR 7.6 and Phase 7.(SCGCQ01519706)
Version 6.714.05.00 ------------------- Fixes: - Fixed issue where a performance drop of around 25% was observed in 4K SR profile for 40 SAS HDD JBOD. (SCGCQ01322976) - Fixed issue where the OS could crash during rebuild with double medium errors. (SCGCQ01316147)
Enhancements: - Added the OEM PNP IDs for JBOD Mode to the SDS and Raid INF file for both Win8 , Win8.1 and Win10. (SCGCQ01391046) - Updated the new name of the controller to ¡°ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter¡± (SCGCQ01263839) - Eliminated use of Depreciated StorPortLogError from all Windows Drivers. (SCGCQ01266362) - Fixed warnings found in Static Driver Verifier (SCGCQ01292775)
Version 6.712.13.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Fixed an issue where StrStr will set qdepth to '1' if either pdqdepth or nodualqdepthreg is set to '1'(SCGCQ01013468) - Fixed an issue where the system was not able to boot into windows 2012 R2 OS installed on R0 VD ,after upgrading Firmware from MR 6.8 to MR 6.10.( SCGCQ00937735) - Added the registry entry of StorPort PowerSrbTimeout for Miniport driver for Server 2016. (SCGCQ01046075) - Fixed an issue where a performance drop of 24% was observed in 4k,8k IO size with Seq writes / reads for 64 & 256 queue Depth in RAID 0 with 24PD (SCGCQ00976733 Port of: Defect - SCGCQ00966844) - Fixed an issue where the driver was not sending any events the listening application during a Reset. (SCGCQ01063100) - Changed drivers so the coalesce capable bit can be set irrespective of regionlock and raid level. (SCGCQ01058107) - Fixed an issue where JBOD would not be seen in the Disk Management after downgrading the firmware from MR 6.10 to MR 6.4(SCGCQ01057383 Port of: Defect - SCGCQ01056377) - Fixed an issue where Region lock and length mismatch while running IO's on VD's with multipath push pull. (SCGCQ01020005 Port of: Defect -SCGCQ00936554) - Fixed an issue where ServeRAID M5120 SAS/SATA controllers which do not support Task management driver were trying to do LUN and Target Reset. (SCGCQ01065588 Port of: Defect - SCGCQ01062954) - Fixed an issue where Windows Driver was not sending any Kill adapter commands to firmware, when the firmware hung at one of the pending command for infinite time. (SCGCQ01134779) - Set the EPDs Queue Depth to divisional algorithm instead of limiting it o 64. (SCGCQ01037085) - Fixed an issue where performance drops of 6% for 24 drive SATA JBOD and 9% for 8 drive R6 could occur. (SCGCQ00969194) - Fixed an issue where Kill adapter seen when running IO's on JBOD with spaces volumes and cable breaker on one of the active paths.( SCGCQ01095397) - Fixed an issue where sgl_end points had different locations based on build path the IO took. (SCGCQ01038940) - Fixed an issue where 24PD 6Gig SASHDD RAID5 in Seq.Write Performance Drops 13-20% with 256K,1MB IOsize in QD=64 Windows 2012R2 OS. (SCGCQ00932828) - Fixed an issue where in the device manager MegaRAID card showed as a SDS card, after upgrading Win 10 X64 driver to latest megasas driver. (SCGCQ01057549) - Fixed an issue where Scheduled DPC sent a DCMD during OCR, causing FW to hit MU fault. (SCGCQ01019278) - Corrected the order for Synchronize Shutdown State machine. (SCGCQ01044278)
Enhancements: - Windows Server 2016 Nanoserver validation for MR (SCGCQ01077991) - Added OEM PnP ID to 3108 ROMB MR release. (SCGCQ01034102) - Added build support for new Windows Event Logging (SCGCQ00498613) - Added support to Windows Driver Build tools for InBox drivers, and renaming them per Microsoft requirements (SCGCQ00716800) - Allow Sync CACHE Command for ServeRAID M5200 and M1200 series controllers by MR Windows Driver (SCGCQ01100038) - Add support for automatic selection of the default driver build parameters file during the build (SCGCQ00685135) - Driver will now check for CanallowSyncCache bit in the ready state, if this bit is set the driver will allow the SYNC_CACHE command for the virtual drivers. (SCGCQ01126148) - Modified INF File for RAID mode for Windows 10 to have a common binary for both SDS and RAID mode. (SCGCQ01041237) - Set Windows Registry Entry to NoClobber for MR WINDOWS DRIVER (SCGCQ01025992) - Added Gigabyte PnP ID to 3108 ROMB MR release. (SCGCQ01056381) - Merged eSDS stream into MR 6.12 Mainline Windows Driver (SCGCQ01002558) - Added the double buffering for each IO by setting the alignment mask to 8 byte in PI environment. (SCGCQ00943713) - Handle ServeRAID 5000 series controller CacheCade SGEs for MR 6.11 Windows Driver. (SCGCQ01099510) - Driver will not log critical events to System Event log when management app is already monitoring events. (SCGCQ01152442 Port of - SCGCQ01128806)
Version 6.710.15.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Fixed an issue where controller reset may occur because the next reply queue is not a factor of 16 (SCGCQ00856764) - Fixed an issue where error logs may show "MonTask" when driver issues a target reset (SCGCQ00867584) - Fixed an issue where system may shutdown unexpectedly during Hibernation or S4 sleep (SCGCQ00878070) - Fixed an issue where the coalescing algorithm to align with max coalesced IO size (SCGCQ00879671) - Fixed an issue where an "FAILED TO FORMAT PARTITION" error may occur in Windows (SCGCQ00906960) - Fixed an issue where some out-of-band command timeouts were not 180 seconds (SCGCQ00930086, Port of SCGCQ00929333) - Fixed an issue where device queue depth for JBODs could exceed 32 for SATA drives (SCGCQ00935693) - Fixed an issue where Windows would not boot after upgrading firmware (SCGCQ00937735) - Fixed an issue where controller may reset after Online Controller Reset (SCGCQ00939172) - Fixed an issue where driver sets "qdepth" argument when "nodualqdepthreg" argument is passed (SCGCQ01013468) - Fixed an issue where system will not return to the saved state after Hibernation (SCGCQ00869496) - Fixed an issue where 4k / 8k performance on a large RAID0 is degraded (SCGCQ00966844) - Fixed an issue where Task Management requests issued to Virtual Drives were not reported to Storport as Invalid Requests (SCGCQ00869511) - Fixed an issue where driver was coalescing across stripes for Fastpath-capable IO on Logical Drives (SCGCQ00896266) - Fixed an issue where noBusyWait was set to false when MaxSRBs was less than 1000 (SCGCQ00908234) - Fixed an issue where Windows may crash when updating to driver 6.710.09.00 (SCGCQ00952825) - Fixed an issue where driver may lose a JBOD after downgrade of firmware using Online Controller Reset (SCGCQ01056377) - Fixed an issue where application may not receive any events during a reset after Event Code 451 "Reset initiated by host" (SCGCQ01063100) - Fixed an issue where system may reset or BSOD with bugcheck DPC_WATCHDOG_VIOLATION when a Virtual Drive is made offline from MegaRAID Storage Manager (SCGCQ00889336, Port of SCGCQ00883872) - Fixed an issue where large RAID0/RAID1 performance may degrade at 4/16/32 IO sizes and queue depth of 1 to 256 (SCGCQ00919204) - Fixed an issue where driver will collect Automatic Event Notifications starting from previous shutdown when an Online Controller Reset is performed (SCGCQ00929450) - Fixed an issue where system may BSOD after firmware update when running driver 6.710.11.00 (SCGCQ01062954) - Fixed an issue where driver doesn't properly set flags for Fastpath IO (SCGCQ00868217) - Fixed an issue where IO was not throttled when pending firmware commands exceeds a threshold (SCGCQ00929431) - Fixed an issue where system may reset when performing multiple background operations on 64 Virtual Drives (SCGCQ00872018) - Fixed an issue where system may BSOD (SCGCQ00925476) - Fixed an issue where sequential write performance may drop for large RAID5 with 256K or 1M IO and queue depth 64 (SCGCQ00932828) - Fixed an issue where Online Firmware Update may be blocked (SCGCQ00938984) - Fixed an issue where updating firmware with Online Controller Reset may cause a BSOD or system hang (SCGCQ00881579, SCGCQ00881576, Port of SCGCQ00871571) - Fixed an issue where error "MonTask: line 6812 in file ../../raid/raidpci.c" may occur when running failover/failback (SCGCQ01020005, Port of SCGCQ00936554) - Fixed an issue where an "L2/L3 Cache Error" may occur on Hibernate (SCGCQ00942766, Port of SCGCQ00939167) - Fixed an issue where driver is not properly setting the supportExtQueueDepth capability in firmware (SCGCQ00938343, Port of SCGCQ00938011) - Fixed an issue where BSOD may occur when downgrading firmware from 24.8.0-0035 to 24.6.0-0040 (SCGCQ00923265, SCGCQ00923263, Port of SCGCQ00919225) - Fixed an issue where LunTargetReset was not supported for Virtual Disks / EPDs (SCGCQ00918009, Port of SCGCQ00906726) - Fixed an issue where driver does not set EOL when SGE count is exactly 7 (SCGCQ00910358, Port of SCGCQ00910349) - Fixed an issue where JBOD performance drops for queue depth 64 or 256 (SCGCQ00914249, Port of SCGCQ00911784)
Enhancements:
- Added ability to set device queue depth based on device type (SCGCQ00880437)
- Added Task Management support for JBOD/system disks (SCGCQ00854636)
- Added logging of Critical Events in Windows Event Logger (SCGCQ00878364, SCGCQ00871878, Port of SCGCQ00868734)
Version 6.708.09.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes - Incorporated MR6.8 driver stream - Fixed an issue where the storport driver could touch Dma32BitAddresses when it should not (SCGCQ00789403) - Fixed an issue where a "Driver detected possible FW hang, halting FW" error may occur during S3 sleep/resume (SCGCQ00840279) - Fixed an issue where newly-converted JBOD drives may not be presented to the OS (SCGCQ00824116) - Fixed an issue where Windows may enter a bootloop after upgrading driver with "Host driver needs to be upgraded to enable extended LD support" in the controller event log (SCGCQ00819305) - Fixed an issue where controller may take a long time to perform Online Controller Reset (SCGCQ00824414, SCGCQ00850132) - Fixed an issue where hibernation may result in BSOD with bugcheck A0 in Windows 2012 R2 (SCGCQ00827000) - Fixed an issue where an unexpected shutdown/reboot may occur during attempt of S4 sleep (SCGCQ00837484) - Fixed an issue where hibernation/dump cases may fail (SCGCQ00790690) - Fixed an issue where an error referencing "line 1276 in file ../../raid/1078dma.c" may occur during Online Controller Reset with JBODs present (SCGCQ00829169) - Fixed an issue where IO may be coalesced even if coalescing is disabled (SCGCQ00838379) - Fixed an issue where the system may BSOD/reboot when a drive is made offline via MSM (SCGCQ00889336) - Fixed an issue where the system may hang or BSOD when performing a firmware update with Online Controller Reset afterwards (SCGCQ00881576) - Fixed an issue where a dirty shutdown could result in false Automatic Event Notifications occurring on next boot (SCGCQ00795404)
Enhancements - Added support for new Windows event logging within the driver (SCGCQ00498613) - Enabled support windows driver sending 1MB IO transfers to firmware (SCGCQ00816315) - Added a feature where an MFI command timeout is handled with an Online Controller Reset (SCGCQ00806523) - Updated queue depth calculation so the queue depth is split equally among LDs and PDs (SCGCQ00818399) - Added support for logging Critical events in Windows Event Logger (SCGCQ00878364)
Version 6.706.06.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Incorporated MegaRAID 6.6 Windows driver stream - Fixed an issue where write performance dropped in Write-Through mode, and read performance dropped in some situations (SCGCQ00751029) - Fixed an issue where Windows might BSOD on reboot after updating to out of box driver version 6.704.12.00 (SCGCQ00793073)
Enhancements: - Added MFI_STAT_CONFIG_SEQ_MISMATCH handling in drivers (SCGCQ00651432) - Added ability to read PCI Domain/Segment information via StoreLib (SCGCQ00712490) - Added ability for driver to differentiate between FastPath IO and LD IO in the PendingIOQueue (SCGCQ00726747) - Added support for 1MB IO if the firmware supports it as well (SCGCQ00712518) - Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00711558) - Added support for ServeRAID M5225, M5110e
Version 6.704.12.00 - Suggested --------------------- Enhancement(s): - Implement PnP ID for 2208 ROMB
Version 6.702.07.00 - Suggested --------------------- Technical Note: - IBM recommend using device driver version 6.600.25.0 with ServeRAID M5110, M5110e and M5016 SAS/SATA controllers as we are currently investigating an issue which causes a fatal firmware error.
Enhancement(s): - Added support for IBM ServeRAID M1210e, M1215 and M5225-2GB SAS/SATA Controllers
Fixes: - Fixed an issue where IO errors could occur while running IO operations on JBODs. - Fixed an issue where device driver is coalescing across stripe resulting in performance degradation. - Fixed an issue where device driver timer not setting back to zero after proper timeout period. - Fixed an issue with M5000 series controller where blue screen occurs on triggering online controller rate reset - Fixed an issue where fileversion and productversion in driver properties do not sync up. - Fixed an issue where IO operations are still blocked, after online controller rate reset.
Version 6.600.25.00-3 - Suggested --------------------- Enhancement(s): - Add support for Windows Server 2012R2
Version 6.600.25.00 - Suggested ------------------- Enhancement(s): - Add support for ServeRAID M5210e and ServeRAID M5210e SAS/SATA Controllers - Fixed an issue where the IO command timeout value for TAPE devices need to be set from OS instead of default timeout value of CUDA. - Fixed an issue where the system hangs on removing the SSD-cache virtual disk while IO is running. - Fixed an issue where INTERRUPT EXCEPTION is not handled. - Fixed an issue where the system crash during sequence reads. - Fixed an issue where the hibernation (s4 sleep state) is not working on Windows Server 2012. - Added Multiphase Resume Feature For Windows 2012 driver. - Modified driver to boot the system to iMR mode if NVRAM is not initialized. - Fixed an issue where Hardware Malfunction BSOD occurs in Windows during second rebuild. - Fixed an issue where performance drop in 256 KB sequence writes by driver. - Fixed an issue where BSOD occurs while creating R10 with spundown drives. - Updated qdepth for jbods min and max values. - Added support for setting the queue depth dynamically for physical disks based on the number of configured devices (JBOD) in iMR firmware. - Fixed an issue where WHQL sleep stress test fails with device driver 5.2.127 - Fixed CrashDump issue in JBOD Mode. - Added JBOD FastPath IO support for SysPD - Fixed an issue where the windows driver was unable to process more than 20 outstanding commands per disk. - Added 4K sector support for Windows 2012
Version 6.506.01 - Suggested --------------- Enhancement(s): - Device diver modified to allow the user to enable and disable online controller reset rate (OCR) without a reboot being required.
Version 5.2.135 - --------------- Enhancement: - Initial release for Windows Server 2012.
Version 5.2.127-1 - Suggested --------------- Enhancement: - Added support for IBM Flex System Storage Expansion Node Note: Device driver version is still 5.2.127.
Version 5.2.127 - Suggested --------------- Fixes - Fixed an issue while updating Win2k8x32 driver the user will get the following error "This device can not start (Code 10)." message - Fixed an issue where MSM 12.01.03.00 alerts are not giving proper windows version. - Fixed an issue where the driver was setting the region lock type even when firmware informs driver to bypass lock. - Fixed Sequential Write performance - Fixed an issue where I/Os stop sporadically with outstanding I/Os. - Changed the behavior of the driver to not send srb flush down by default; it manually checks the inf file for the device ids or on a system with these devices. - Fixed an issue where Windows LSI Driver megasas2.sys has inconsistent File version.
Version 5.2.112 - Suggested --------------- Fixes - Addressed Event 11 error in Windows system event log in Multipath configuration with Windows 2003. - Fixed issue where an Event 11 error will log in the Windows 2008 system event log during a warm or cold reboot. (RETAIN TIP H204972) - Fixed BSOD, RQ_LESS_THAN_OR_EQUAL, which can during heavy IO in large RAID 6 configurations.
Version 5.2.103 - Suggested -------------- Enhancements - Added support for ServeRAID M5016 - Added support for Windows 2008 R2 SP1
Fixes - LSI Channel fixes
Version 4.36.0 - Non-critical -------------- Fixes - Fixed issue where Windows 2003/2008 will blue screen during heavy periods of I/O - Fixed issue where a yellow bang will occur in Windows device manager when using the EXP2512/2524
Version 4.35.0 - Non-critical -------------- Enhancements - Enhancement for online controller reset support for 1078 (ServeRAID MR10x) controllers
Fixes - Fix issue where the application-DeviceIoctl would request sense IO, and device would generate sense information, which would get transferred to a wrong address. - Fixed issue where some servers will hang on shutdown of Windows due to Power SRB handling - Fixed verification at 0xC4 with verifier handling violation due to mmMIOspace call from miniport driver. - Fixed iMR performance problem with multiple virtual drives by allowing the driver to send SCSI status as task full. - Fix order IO coalescing.
Version 4.32a - Non-critical -------------- - Fixed issue with "Extract to Hard Drive" option
Version 4.32.0 - Non-critical -------------- - Fixed issue on Windows 2003 where after shutdown the user will see unexpected shutdown message in the next reboot due to driver not unregistering CPX interface. - Fixed issue where the ServeRAID M1015 will hang when performing OCR with IO with a degraded RAID 1 or rebuilding RAID 1 array. - Fixed issue where the ServeRAID M1015 will hang when performing OCR with IO on RAID 1 and RAID 5 arrays. - Fixed issue where BSOD error occurs, “DRIVER_POWER_STATE_FAILURE STOP: 9F,” during Windows 2008-R2 installation and before first reboot.
Version 4.24.0 - Non-critical -------------- Enhancements - Added support for ServeRAID M5025.
Fixes - Fixed issue with Event ID 51 messages - Fixed issue where the Operating System hangs during reboot after stopping IO and clearing config. - Fixed issue with command Timeout to driver. - Fixed issue where the file system view shown as 'RAW' instead of 'NTFS/FAT' - Fixed issue where an adapter reset would cause a BSOD
Version 4.17.2 - Non-critical -------------- - Added support for ServeRAID M1015. - Implemented some performance enhancements to support ServeRAID M1015 controller. - Fixed an issue where the system could hang when a virtual disk is deleted or a configuration is cleared during heavy I/O.
Version 4.13 - Non-critical ------------ - Added logic to support next-gen SAS2 controllers. - Added support for the ServeRAID M5015 and M5014 SAS/SATA controllers.
Version 3.9 - Suggested ----------- - Added support for the IBM ServeRAID MR10ie (CIOv) SAS controller. - Added support for MSI (Message Signaled Interrupts) to the Windows Server 2008 driver. - Fixed an issue that could cause a system freeze when a system shutdown is initiated while the system is under heavy I/O stress.
Version 2.23 - Suggested ------------ - Added support for the IBM ServeRAID MR10is SAS controller. - Fixed an issue where, after a firmware hang, the driver would completely halt the firmware, resulting in the rejection of all additional commands. - Fixed an issue where the OS on the first controller would become unstable after the second controller encounters a double bit ECC error. - Changed the signing process to ensure that the digital signature would not expire.
Version 2.20 - Suggested ------------ - Added support for the IBM ServeRAID MR10il SAS controller. - Added support for Windows Server 2008. - Implemented several changes to prevent ISR calls at certain times. - Fixed a text issue in the INF file. - Fixed an issue where S3 Standby would delay and sometimes fail during resume from Sleep state.
Version 2.17 - Suggested ------------ - Added support the IBM ServeRAID MR10i, MR10k, and MR10M SAS controllers.
Version 1.24 - Suggested ------------ - Forced the PnP Manager to rescan the bus once "Dead Adapter" is set. This prevents a manual rescan, as well as preventing I/O retries which fill up the event log. - Modified the driver so that it will no longer allow any commands to go to the firmware once the restart timer is on.
Version 1.23 - Suggested ------------ - Implemented EnableDma64BitAddresses argument, which allows the driver to support 64-bit DMA addressing regardless of whether the system supports 64-bit addressing. - Fixed an issue where the driver was not updating the dataTransferLength value, which caused missed comparesions between the dataTransferLength value returned by the driver and the value returned by the firmware.
ibm_dd_sraidmr_6_714_15_00_windows_32-64_chg
=============================================================================== Emulex 16GB FC Firmware Package ===============================================================================
Firmware Version: 10.4.303.3 Supported On: System x Rack
Problems Fixed: - VF speed is showing wrongly in ethtool and Ocm. - Firmware download using ethtool -f command is failing with opcode 172-1 failed:status 100-208 - Can not set the DelayDeviceDiscovery to Max (255) by ASU tool - Ports intermittently logging in to Brocade switch as G-Port
Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Problems Fixed: - Blue screen after firmware flash to with virtualized WWPN
Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Incremental Interoperability: - Grantley based ITE
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 10.2.377.18 Supported On: System x
Problems Fixed: - Link does not recover during IO + Port Cycling with FW 1.1.43.3 - BIOS versions return multiple values - LPe16k point to point (direct attached) connection not bootable in legacy BIOS - LPe16k point to point (direct attached) connection performance issues in legacy BIOS
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex
Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change - Reported firwmare version in CMM is intermittently incorrect - Unable to set pause Flow control when connected to DCBX switch with PFC off - during cable pull testing a 40 second delay in link up experienced with Brocade switch ports - I/O completion and abort completion WQE are generated out of order - Unexpected WCQE in RQ CQ seen in RXRI mode while performing cable pulls
Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console) - Crosslink & Express Lane on LPe16k based solutions
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 1.1.43.21 Supported On: IBM System x
Incremental Interoperability: - None
Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu
Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x
Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup
Firmware Version: 1.1.21.9 Supported On: IBM System x
Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics
Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches
IBM HBA/LSI 6Gb SAS/SATA/SSD Driver for Windows 2012 R2/2012/2008 R2/2008/2003
Supported Controllers: - IBM N2125 SAS/SATA Controller (46C9011) - IBM N2115 SAS/SATA Controller (46C8989) - ServeRAID H1135 Controller for IBM Flex System and BladeCenter (90Y4750) - ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492) - IBM 6Gb SAS HBA (46M0907) - IBM 6Gb SSD HBA (68Y7362) - Onboard LSI 2004 SAS
NOTE TO SERVICE - Reference RETAIN #N/A
2.00.75.00 - Low Probability of Occurrence/Special Case ------------------
Enhancements: - Generate a fault/alert when junction temperature approaches max spec (SCGCQ00559883)
- Added timer to prevent ATA commands from hanging. (Needed as part of SCGCQ00694282 fix) (SCGCQ00751758)
Fixes: - New drive failed to be recognized after replacing a failed SATA HDD (SCGCQ00694282)
Version 2.00.69.01 - Suggested ------------------ Enhancement(s): - Added driver configuration parameter to control MaxDevices during crash dump mode. Fixes: - Fixed an issue where a blue screen could occur with driver fault AD010042. - Fixed an issue where PFA LED is not turning off after the PFA drive is removed from the back plane.
Version 2.00.60.03 - Suggested ------------------ Enhancements(s): - Added support for Windows 2012 R2
Version 2.00.60.00 - Suggested ------------------ Enhancements(s):\ - Added support for 8MB+ IO's - Modified sense data processing code to check for an ATA Passthrough command (either 12 or 16 byte). - Added RTTrace hooks to increase logging coverage within driver. - Implemented Extended SRB support (StorPort enhancement) in driver. - Added checks to catch physical DMAable memory allocations outside a single 4GB block as required by the adapter hardware.
Fixes:. - Fixed an issue where cable break between enclosures causes the adapter to reset. - Fixed an issue where MSM sends input/output control causing BSOD in Windows 2012 Extended SRB driver. - Fixed an issue where SAS2FLASH sends input/output control causing BSOD in Windows 2012 Extended SRB driver. - Fixed data alignment issue which could result in corrupt sense data under Windows 2012. - Changed RTTRACE version to match record structure used by driver. - Fixed an issue in Windows Server 2003 where executing LSIutil 1.65 Option 65 virtual serial port causes a bluescreen if memory has been severely fragmented.
Version 2.00.45.00 - Suggested ------------------ Ehancement(s): - Add support for ServeRAID H1110 SAS/SATA Controller for IBM System x - Add conversion of sense data descriptor format to fixed format, so drives 2.1TB in size and greater can return descriptor format sense data. For these drives to work properly under Windows, the miniport needs to convert the descriptor format sense data to fixed format before returning the sense data up the stack.
Fixes: - Add check for sense data type (fixed vs. descriptor) in CheckSmartInfo where large physical drives 2TB in size and greater use the descriptor format for sense data in order to pass back 64-bit LBA addresses. Most drives use the fixed format sense data, is the only format the upper layers of the Windows stack supports
Version 2.00.17.30 - Initial release ------------------ ibm_dd_mpt2sas_2_00_75_00_windows_32-64_chg
ServeRAID M1000 Series SAS/SATA Controller Firmware Update
Adapters Supported: ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
Version 20.13.1-0254 --------------------
Version 20.13.1-0245 - Moderate Impact/Low Probability of Occurrence --------------------- - Fixed an issue where virtual drivers become inconsistent after the system an AC failure. (SCGCQ00897229) - Fixed an issue where Illegal request sense messages are seen repeatedly in FW logs due to attempts to collect temperaure for pds which does not support page (0x2F) at every smart poll interval. (SCGCQ00898459) - Fixed an issue where command "cli set securitykey=Lsi@12345" fails with error code "1001" and error message "invalid key". - Added a warning message when preboot configuration utility is Disabled but the user tries to launch it. (SCGCQ00662761) - Fixed an issue where WebBIOS Advance software option menu from main page could hang the system. (SCGCQ00683327) - Updated the drive speed display string to support 12Gb/s (SCGCQ00751036) - Corrected inconsistency in size showing in for total capacity property between webBIOS and MSM (SCGCQ00752176)
Version 20.13.1-0200 - Critical ------------------- Enhancement: - Support LSI iMR Private Interface for Intel iOMMU/VT-d Support when combined with latest system uEFI - Display drive speed for 12 GB Seagate hard drives in MSM. - List battery status in BIOS as N/A for iMR controllers Fixes: - Fixed incompatibility issue with System x3200/3250 M3 causing hang condition (RETAIN Tip H211826) - Fixed an issue where self-encrypting (SED) hard disk password fails to allow access to virtual disk configurations. - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where WebBIOS advanced software option locks the server. - Changed patrol read completion time calculation to include time for associated IO operations. - Fixed SGPIOs signal issue.
Version 20.11.1-0184 - Suggested ------------------- Fixes: - Updated SBR to avoid an errata that could cause correctable CPU errors on some systems. - Fixed an issue where NULL events may show in event log, preventing capture of controller event logs.
Version 20.11.1-0137 - Suggested ------------------- Enhancement(s): - Update recovery mode page (WriteRetryCount and recoveryTimeLimit) during discovery of a drive and during spinup recovery when sense 6/29 is received.
Fixes: - Fixed an issue where certain drives were reporting a temperature of 65 degrees Celsius. - Fixed an issue where systems with SSD HDD will pop up an error message after creating a virtual drive via HII on M1115. - Fixed an issue where the drive state is not modified when a recon virtual drive is created from the reboot path.
Version 20.10.1-0107 - Suggested ------------------- Fixes: - Fixed grammatical errors in WebBIOS. - Fixed an issue in WebBIOS Drive Group Definition screen where enclosures should not be selectable in the Drives column. - Fixed an issue in uEFI-WebBIOS where the white bars do not match up under VD properties page. - Fixed an HII browser issue where a drive performing a copyback displayed the state as "Replacing" but other utilities showed the state as copyback. - Fixed an HII browser display issue where SATA drives showed "0" for the value of RPM under drive properties. - Fixed a display issue where the HDD port number showed incorrectly in an HII browser. - Fixed an HII browser issues where creating a global hotspare gave the user an error message. - Fixed an HII browser issue when security is changed with local key management the changing security report current mode is disabled as external keu management. - Fixed an HII browser issue where the user got the following error message, "The request command has invalid arguments," when changing the security key report. - Fixed an HII browser issue where the user was unable to save the configuration after adding an extra span during array creation. - Fixed an HII browser issue where the return value was not correct when the browser called extract config with a result of null.
Version 20.10.1-0101 - Suggested ------------------- Fixes: - Fixed an issue where a system uefi error will occur when the bootTargetId is set to 0. - Fixed a problem where the firmware will allocate the sata bbl entry for the drive when moved from unsupported to supported. - Fixed a firmware issue where the TargetId for the recon LD should be set to its original LD. - Fixed a HII error message "Question Value mismatch with Option value!" after selecting factory defaults in HII. - Fixed an issue where the firmware fails to create the configuration and utilities fail to report the VD size after the reconstruction.
Version 20.10.1-0091-01 - Non-Critical ------------------- Fix - Fixed issue where update may fail to find all supported controllers.
Version 20.10.1-0091- Suggested ------------------- Enhancement: - Add support for ServeRAID M1115
Fixes: - Fixed issue where after starting a reconstruction on a RAID 0 the progress %, does not increase. - Fixed an issue where a new drive, inserted after a drive failure, goes to JBOD and not auto rebuild. - Fixed physical drive count issue that stated more than (16) devices already exists
Version 20.10.1-0069- Suggested ------------------- Enhancement: - ServeRAID M1015 Dimmer Switches are disabled by default.
Fixes: - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Fixed issue where WebBIOS gives garbled message when enabing FDE on an existing Disk Group - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed a problem where firmware was taking to long to complete the PCI config read. Causing the system to generate an NMI. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed an intermittent RAID key failure during power-on.
Version 20.10.1-0052- Critical ------------------- Enhancement: - Add support to pass SMART errors for JBOD drives to MSM
Fixes: - Added check to return SCSI sense Check condition if PMI is set and LBA is non zero for SCSI Read Cap 16. - Fixed issue where a bluescreen occurs handling RAID 1 with HSP and medium errors. The bluescreen occurs becausethe driver timesout while fw is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early
Version 20.10.1-0045 - Critical ------------------- Fix: - Fixed issue where firmware has incomplete writes during power fail and recovery
Version 20.10.1-0036 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users to downlevel firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur
Version 20.10.1-0022 - Critical ------------------- - Fixed issue where Windows 2008 R2 WS08 cannot be installed properly on ServeRAID M1015 SATA JBOD with a uEFI boot. - Added warning message when user tried to change more then 16 drives to JBOD. - Addressed a problem where direct attached drives are given incorrect slot numbers - Added fixes from LSI channel products. - Fixed issue where a single JBOD drive will not boot after a Windows 2008 R2 installation.
Version 20.5.1-0014 - Critical ------------------- - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed problem where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 20.1.1-0059 - Critical ------------------- Fixes: - Fixed an issue where a physical drive that is changed to JBOD from powersave will become unconfigured good again - Addresses an issue where data becomes inaccessible when a drive is secured after data has been written
Version 20.1.1-0049 - Suggested ------------------- Enhancement - Support M1000 key for RAID 5 and SED support
Fixes: - Fixed an issue in M3950M3 where webbios would hang - Fixed an issue where the controller properties in WebBIOS such as Rebuild, CC and BGI are not changing when we use up and down arrow keys. - Fixed an issue where Enclosure ID's are not being shown in MSM
Version 20.1.1-0046 - Suggested ------------------- - Enabled support for the ServeRAID M1000 Series Advanced Feature Key.
Note: All Logical Drives must previously have the encryption enabled before data is written on to the SED drives. Please read Retain TIP H123152 for more details.
Version 20.1.1-0042 ------------------- - Initial release ibm_fw_sraidmr_1000-20_13_1-0254_windows_32-64_chg
=============================================================================== Emulex NIC Device Driver for Windows ===============================================================================
Device Driver Version: 10.4.255.23 Supported On: System x Rack
Problems Fixed: - OCe14000 with LRO enabled causes OS to reboot - Observing "IOCTL to firmware failed" in the Diagnostics tab after installing the Driver to the Virtual Function
Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products
Known Issues: - RoCE support is limited to named applications. Contact your local OEM Sales Support for more information.
- There is no benefit from using NVGRE on more than one vNIC attached to the same physical port. As such, only one vSwitch should be attached to a physical port. Attaching more than one vSwitch to a physical port could cause a dramatic decrease in performance. This is a permanent limitation
Device Driver Version: 10.2.531.0 Supported On: Flex
Problems Fixed: - BSOD when booting to windows 2012 R2 with HyperV with 4x CN4054 in system - Driver reports too many VMQ resources
Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products
Known Issues: - RoCE support is limited to named applications. Contact your local OEM Sales Support for more information.
- There is no benefit from using NVGRE on more than one vNIC attached to the same physical port. As such, only one vSwitch should be attached to a physical port. Attaching more than one vSwitch to a physical port could cause a dramatic decrease in performance. This is a permanent limitation
Device Driver Version: 10.2.413.1 Supported On: System x, BladeCenter and Flex
Problems Fixed: - Packet loss observed during affinity changes. During the change, a 'pause' occurs, packets will get dropped, bandwidth utilization will drop because of the stall, and overall performance will be inconsistent.
- When using multi-channel in a vSwitch environment, map one PF to the hyper-visor vSwitch and then use the other PF’s/vNICs for live migration network, FCoE/iSCSI, Management network and the like in order to get the best performance.
Incremental Interoperability: - Grantley based ITE
Known Issues: - RoCE support is limited to named applications. Contact your local IBM Sales Support for more information.
- There is no benefit from using NVGRE on more than one vNIC attached to the same physical port. As such, only one vSwitch should be attached to a physical port. Attaching more than one vSwitch to a physical port could cause a dramatic decrease in performance. This is a permanent limitation
Device Driver Version: 10.2.370.18 Supported On: System x and BladeCenter
Problems Fixed: - Network connectivity is getting lost for VMQ interfaces during VMQ CPU affinity stress test
Incremental Interoperability: - None
Known Issues: - RoCE support is limited to named applications. Contact your local IBM Sales Support for more information. - Packet loss observed during affinity changes. During the change, a 'pause' occurs, packets will get dropped, bandwidth utilization will drop because of the stall, and overall performance will be inconsistent. - When using multi-channel in a vSwitch environment, map one PF to the hyper-visor vSwitch and then use the other PF’s/vNICs for live migration network, FCoE/iSCSI, Management network and the like in order to get the best performance. - There is no benefit from using NVGRE on more than one vNIC attached to the same physical port. As such, only one vSwitch should be attached to a physical port. Attaching more than one vSwitch to a physical port could cause a dramatic decrease in performance.
Device Driver Version: 10.2.348.2 Supported On: IBM System x
Problems Fixed: - BSOD after running IO's using NVGRE offload for 16VM's, also affects VMQ and SRIOV - Option to enable/disable RSS not visible in NIC advanced properties - Network connectivity is getting lost for VMQ interfaces - Performance and Fairness for 16VM's is uneven on Windows 2012 R2
Known Issues: - RoCE support is limited to named applications. Contact your local IBM Sales Support for more information - Packet loss observed during affinity changes. During the change, a 'pause' occurs, packets will get dropped, bandwidth utilization will drop because of the stall, and overall performance will be inconsistent. - When using multi-channel in a vSwitch environment, map one PF to the hyper-visor vSwitch and then use the other PF’s/vNICs for live migration network, FCoE/iSCSI, Management network and the lie in order to get the best performance. - There is no benefit from using NVGRE on more than one vNIC attached to the same physical port. As such, only one vSwitch should be attached to a physical port. Attaching more than one vSwitch to a physical port could cause a dramatic decrease in performance.
Device Driver Version: 10.2.261.11 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - When MAC learning is enabled, driver should not drop internally switched packets - Incorrect Port numbering in nic multichannel tab - No link down on UMC 0 bw min and max - BE3: very low throughput transmit on SR IOV Guest OS (netperf less than 100Mbps although 10Gb link) - BE3 Win2k12R2 Hyper v server crashed during the creation of virtual switch using the LACP teamed adapter - NIC Teaming (failover/failback) fails on HS23 LOM
Incremental Interoperability: - ARI (PCI-SIG specification) - RDMA over CEE (RoCE)
Known Issues: - RoCE support is limited to named applications. Contact your local IBM Sales Support for more information - When using VMQ with Windows Server 2012 or 2012R2, the user may experience VM connectivity loss, packet drops, system hangs, inability to shutdown VMs and possible system crashes on shutdown.
Device Driver Version: 10.0.718.26 Supported On: IBM System x
Problems Fixed: - VMQ driver option incorrectly available for 1Gb ports of BE3 - BE2 and BE3: Hitting Nic initialization failure after updating driver - Update custom property page display for BE3R - Windows NIC driver always reports initial link status as UP
Device Driver Version: 4.6.203.1 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - HyperV VM's tagged VLAN's did not get an IP Address - NIC Function Properties > Status for PCI Express Link Speed says Invalid Link Speed detected. - iSCSI ports of CNA card in ESXi 4.1u3 OCM GUI (vCenter plug in) is not getting displayed
Device Driver Version: 4.4.176.2 Supported On: IBM Flex
Device Driver Version: 4.2.390.6 Supported On: IBM System x and BladeCenter
Problems Fixed: - Cleaned up inf file - TOE Offload Fails when the same neighbor is added more than once
Incremental Interoperability: - Windows 2012
Known Issues: - Switch Independent Mode not supported in a HyperV environment - Default values vary between inbox and out of box drivers. For example: Configuration section - Wake On LAN - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ Performance section - Maximum Number of RSS Queues - Inbox default is ‘4’ - out-of-box default is ‘8’ - Virtual Machine Queues - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ You may select the button to reset all driver settings to defaults after any installation.
Device Driver Version: 4.1.370.0 Supported On: IBM System x, BladeCenter, and Flex
Incremental Interoperability: - Initial release for IBM Flex
Problems Fixed: - HS23 - Sleep Stress test failed with bugcheck C4 during driver verify - TOE with RSC enabled causes Network to go down - Augmented WOL Capabilities - Driver parameter query failures - BSOD 9F during shutdown if device stops responding - RSS queues may change port during MPRestart and MPPause
Device Driver Version: 4.1.334.25 Supported On: IBM System x and BladeCenter
Problems Fixed: - Emulex: Large Receive Offload support needed in Windows NIC driver - Win WoL: Need to report WoL based on ARM reported capabilities - update the driver strings for existing cards - RSS code may access PerMessage beyond end of array - 16 queue RSS for BE3 on Windows 2008 R2 - fix unverified mode of occfg to allow customer workarounds - 16 queue RSS lockup if SRIOV enabled in registry - Standard Property Page for 1 port Windows Azure card - Timeout RQ flush to avoid bugcheck during shutdown - Change receive buffer alignment to use Windows 2008 R2 TCPIP fast path - Emulex: BSOD - Replacing BE3 card with a BE2 card after installation of new kit driver and firmware on Win 2k3 SP2 R2x64 (vNIC enabled IBM machine) - be2nd62.inf failed ChkInf - VMQ registry keys displayed in Windows 2008 - be_function_prepare_nonembedded_ioctl overwrites version field - autoi reboot fails on Win2K8 x64 when verifier enabled - PCI ID: Updates for Endeavor 2 for IBM- PCI IDs Rev 1.22 - Emulex NIC driver causes BSoD during shutdown whenever disable firewall or join domain network - Sleep Stress test failed with bugcheck C4 during driver verify - Disable TOE by default for IBM - BSOD 9F during shutdown if device stops responding
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.23.02 Build ID: IBM12302 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.23.02 - Update Utility release for IBM x86 servers.
SAS 3.5"
- ST1000NM0045, ST2000NM0045, ST4000NM0025 to LK85
- ST6000NM0095 to LC85
SAS 2.5"
-HUC101860CSS20E, HUC101890CSS20E, HUC101812CSS20E, HUC101830CSS20E to P2H6
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.23.01 Build ID: IBM12301 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.23.01 - Update Utility release for IBM x86 servers.
Note 1: *- Fix bug : Sweep seek not scheduled after forced power condition
- ST2000NM0043, ST4000NM0043 to EC5K/FC5E - see Note1 * above
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC6J/FC6E -see Note1 * above
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6G -see Note1 * above
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.23.00 Build ID: IBM12300 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.23.00 - Update Utility release for IBM x86 servers.
Note 1: *- Add Lenovo Branded Part Number in supporting list
Note 2: *- Remove the legacy HDD/SSD in this Update program, the drives were out of production by 4Q2014 or no firmware changes since 1Q2014. There is a seperate update program to support these drives.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to LC5H - See Note 1* above
- ST2000NM0043, ST4000NM0043 to FC5D - See Note 1* above
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to FC6D - See Note 1 * above
- ST3300657SS, ST3600057SS to LA5A - See Note 1* above
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to K3LC - See Note 1 * above
- HUS724020ALS61, HUS724040ALS61 to P3LC - See Note 1* above
- WD1001FYYG-23S, WD2001FYYG-23S to XA39 - See Note 1 * above
- WD5003ABYX-23 to WC42 - See Note 1 * above
- ST1000NM0045, ST2000NM0045, ST4000NM0025 to LK84 - See Note 1* above
- ST6000NM0095 to LC84 - See Note 1* above
- MG04SCA60EE to TG45 - See Note 1* above
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6F
SAS 2.5"
- ST300MM0006, ST600MM0006, ST900MM0006 to L56R - See Note 1* above
- ST300MM0026, ST600MM0026, ST900MM0026 to F56F - See Note 1* above
- ST1200MM0007 to L57D - See Note 1* above
- ST1200MM0017 to F578 - See Note 1* above
- ST300MP0005, ST600MP0005 to L67J - See Note 1* above
- ST300MP0015 to F674 - See Note 1 * above
- ST9146853SS, ST9300653SS to L63M - See Note 1* above
- ST9500620SS, ST91000640SS to LD2L - See Note 1* above
- HUC156030CSS20, HUC156060CSS20 to K2GF - See Note 1* above
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to K2EK - See Note 1* above
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to P2EK - See Note 1* above
- AL13SEB300, AL13SEB600, AL13SEB900 to TB37 - See Note 1* above
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to K4CC - See Note 1* above
- HUSMM1640ASS20E, HUSMM1680ASS20E to P4CC - See Note 1* above
- ST1000NX0453 to LD48 - See Note 1* above
- HUC101860CSS20, HUC101890CSS20, HUC101812CSS20, HUC101830CSS20 to K2H9 - See Note 1* above
- HUC101860CSS20E, HUC101890CSS20E, HUC101812CSS20E, HUC101830CSS20E to P2H5 - See Note 1* above
- HUC101818CS420 to J5H9 - See Note 1* above
- HUC101818CS420E to N5H9 - See Note 1 * above
- ST1800MM0018 to L59B - See Note 1* above
- ST1800MM0068 to F594 - See Note 1* above
- AL14SEB180E to TL43 - See Note 1 * above
- USMR1625ASS20E to P4C9 - See Note 1* above
SATA 3.5"
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to LB5F - See Note 1* above
- WD1004FBYZ-23YC, WD2004FBYZ-23YC to WH03 - See Note 1 * above
- ST1000NM0055, ST2000NM0055, ST4000NM0035 to LJ84 - See Note 1* above
- ST6000NM0115 to LB83 - See Note 1* above
- MG04ACA600E to TJ42 - See Note 1* above
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to LE2B - See Note 1* above
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MC50 - See Note 1* above
- SSDSC2BB800G4I to D201NE40 - See Note 1* above
- ST1000NX0423 to LE45 - See Note 1* above
SATA 1.8"
- MTFDDAA480MBB, MTFDDAA800MBB to MC50 - See Note 1* above
Below drives are removed from the program - See Note 2* above
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.21.00 Build ID: IBM12100 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.21.00 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5K
- ST2000NM0043, ST4000NM0043 to EC5H
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6E
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC6E
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to MPXSJ3LA
- HUS724020ALS61, HUS724040ALS61 to MPXSN3LA
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to VCXSA810
SAS 2.5"
- HUC156030CSS20, HUC156060CSS20 to KFXSJ2G8
- HUC101212CSS60 to CPXSJ2MC
- HUC101212CSS61 to CPXSN2MC
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to CEXSJ2EL
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to CEXSN2EL
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to SPXSJ4CC
- HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to SPXSN4CC
SATA 3.5"
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD40
- ST2000NM0024, ST4000NM0024, ST6000NM0024, ST5000NM0024 to BB67
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5G
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB47
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA35
- STECM8PSB2 to 2864/SM08
SATA 1.8"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB47
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.20.00 Build ID: IBM12000 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.20.00 - Update Utility release for IBM x86 servers.
Note: *- Update the firmware on SAS/SATA SSDs to fix PSIRT issue with Intel SSD's.
This package acknowledges support and may include updates for drives with product ID strings of:
SATA 2.5"
- SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB480G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA39.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC34.
SATA 1.8"
- SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to D201NE40.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.19.06 Build ID: IBM11906 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.19.06 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
- Remove TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I from FW update utility for new code updating break Raid.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.18.03 Build ID: IBM11803
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.18.03 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read.
RETAIN TIP: H214635 MIGR-5098037
SAS 3.5"
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6B - similar to Note * above.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5J - Enhance Dither Algorithm to prevent dwelling during Idle environments. - ST2000NM0043, ST4000NM0043 to EC5E - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SAS 2.5"
- TXA2E21600GA6I to GB7P - add support in profile.
- HUC156030CSS20, HUC156060CSS20 to J2G6 - add support in profile.
SATA 3.5"
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB68 - similar to Note * above.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5F - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SATA 2.5"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB42 - add support in profile.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I to D201NB39 - add support in profile.
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read. RETAIN TIP: H214635 MIGR-5098037
This package acknowledges support of qualified devices and may include updates for drives with product ID strings of:
SAS 3.5"
- HUS724020ALS61, HUS724040ALS61 to N3L6 - internal updates.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5H - See Note * above.
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC66 - see Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- Other drive codes are present for support identification.
SAS 2.5"
- WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA34 - follow-on release. - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC33 - follow-on release.
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EH - follow-on release.
- TXA2D20200GA6I, STXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I to GB7P - enhancements.
- ST300MM0006, ST600MM0006, ST900MM0006 to B56T - See Note * above.
- ST300MM0026, ST600MM0026, ST900MM0026 to E56E - See Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- ST1200MM0007 to B57E - See Note * above.
- ST1200MM0017 to E577 - See Note * above.
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to J4C8 - See Note # above - HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to N4C8 - See Note # above
- Other drive codes are present for support identification.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1D - performance inhancements.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5C - See Note * above.
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB65 - See Note * above.
- WD2003FYYS-23W0B0 to WA36 - configuration additions.
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD39 - configuration additions.
- HUA723030ALA6 to MKAOA930 - enhancements. - HUA723020ALA6 to MK7OA930 - enhancements.
- Other drive codes are present for support identification.
SATA 2.5"
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA34 - ship level.
- Other drive codes are present for support identification.
SATA 1.8"
- Drive codes are present for support identification.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.05 Build ID: IBM11605
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.05 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4B - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L6 - Fixed unexpected 02/04/11 error; Fixed a drive logic self-initiated reset on read/write long commands; Fixed a problem with large write sequential transfers.
SAS 2.5"
- ESXSST9500620SS, ESXSST91000640SS to BD2K - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
SATA 2.5"
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.04 Build ID: IBM11604
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.04 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB42 - > A drop in host power supply may cause bad block growth > The bad block table may not properly increment > Background activity may continue after STANDBY, STANDBY IMMEDIATE, or SLEEP > ID173/202 may show incorrect value when the NAND erase count exceeds 3000 > Changed DRAM timing > Event log may be programmed when supply voltage from host is out of specification
- SSDSC2BB012I4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix that corrects a condition that may cause the drive to not respond.
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND34 - will require two update runs and system reboots for device fw update to complete--Please See the limitations in readme for details.
> Performance improvement on sub-4KB sequential write > Fix drive reports higher than actual data units read and write > Fix drive incorrectly counts unsafe power shutdown events on warm reboots
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.03 Build ID: SAS11603
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.03 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST2000NM0034, ESXSST4000NM0034, ESXSST6000NM0034 to BC67 - GA code. - ESXSST2000NM0054, ESXSST4000NM0054, ESXSST6000NM0054 to EC66 - GA code.
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA39 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SAS 2.5"
- ESXSTXA2D20200GA6, ESXSTXA2D20400GA6, ESXSTXA2D20800GA6, ESXSTXA2E21600GA6 to GB7P - fixes implemented to support PI issues.
- ESXSST300MP0005 to B675 - GA code. - ESXSST300MP0025 to E671 - GA code.
- ESXSST300MP0035, ESXSST600MP0035 to B683 - GA code. - ESXSST300MP0045, ESXSST300MP0045 to E685 - GA code.
- ESXSST300MX0012, ESXSST600MX0052 to BH53 - GA code.
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23DS to ZA34 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; drive was reporting 0B/11 instead of 03/11. - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC33 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1C - GA code
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE2B - Update configuration change.
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB34 - > Some Out of Range LBAs accepted by NCQ commands where they should be aborted. > SataDownShift.srt failed, Smart attribute Raw lost with perform dirty pwr cycle . > Low Power Entry Bug Identified from Marvell Code Review > Track Timeout, Marvel 373 sequencer issue > Unreasonable ECC count in SMART ID 195
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program for Linux. Version 1.16.00 Build ID: SAS11600
******************************************* IBM SAS/SATA HDD/SSD Update Program Version 1.16.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37 - Resolves drive initiated reset (DBS (Debug Stop event)) encountered under a narrow timing window (~1ns) for specific command/access patterns, due to the drive’s handling of command automation where it was possible for an internal hardware resource conflict to occur between two tasks.
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NSto BE2A
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA37
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND32 - will require a system reboot for device fw update to complete.
********************************************************************* SAS/SATA HDD/SSD Update Program Version 1.15.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37
- ST9500620NS, ST91000640NS to BE2A
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9500620NS, ST91000640NS
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA36
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
NOTE TO SERVICE - Reference RETAIN TIP H29851 ******************************************* SAS Hard Disk Drive Update Program Version 1.14.04 Critical Release Reference RETAIN TIP H29851
This package includes updates to drives with product ID strings of:
SAS 2.5"
Initial code Release - SMK3001GRDB, SMK6001GRDB, SMK9001GRDB to SB35
SATA 2.5"
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA36 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB37 - fix to prevent possible drive lock up during format.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA36 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB37 - fix to prevent possible drive lock up during format.
=================================================================== IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to E568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX ibm_fw_hddlenovo_sas-1_23_02_windows_32-64_chg
=============================================================================== Emulex iSCSI Device Driver for Windows ===============================================================================
Device Driver Version: 10.4.245.0 Supported On: System x Rack
Problems Fixed: - Crash dump is not getting generated after OS Crash in iSCSI LUN using Skyhawk CNA
Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.254.0 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Cleaned up PCI ids in the inf file - iSCSI driver's usage of EQ/CQ/RQ doorbell formats for XE-102 and XE-104 - Mis-match in product version between NIC and iSCSI drivers - Lun Reset/Target Reset can hang under some errors in Windows iSCSI driver - Random crashes while load/unload surf driver
Device Driver Version: 10.0.732.0 Supported On: IBM System x
Problems Fixed: - Windows2012 blue screen dpc_watchdog_violation 256 targets during driver disable/enable - Gracefully Handle insufficient buffer ioctl response - Support logging into as many iSCSI targets as the firmware will report - Remove link speed on properties page iSCSI driver - DVL log creation fails for iSCSI driver
Device Driver Version: 4.1.334.0 Supported On: IBM System x, BladeCenter, and Flex
Incremental Interoperability: - Initial release for IBM Flex
Problems Fixed: - Logout handling on boot session when multiple sessions exists to the same boot target - Add PCI ID as per Rev 1.18 for Windows iSCSI Driver - Multipath IO fails producing a BSOD - Persistent login to Max targets + 1 from WMI causes a hang - Update Nomad Device Name as per 1.19 for Windows iSCSI drivers - PCI ID: Updates for Endeavor 2 - PCI IDs Rev 1.22
=============================================================================== Emulex FCoE Device Driver for Windows ===============================================================================
Device Driver Version: 10.4.246.0 Supported On: System x Rack
Problems Fixed: - System crashes when running a diagnostic Quick test on a disabled port if port hasn't been reset yet
Incremental Interoperability - Improved debug capability in driver logging - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.261.4 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - ABTS sent by tape device ignored by HBA - BSOD issue during CPU Hot replace test - XE102/XE104 - OCManager reports link down on both ports
Device Driver Version: 10.0.720.0 Supported On: IBM System x
Problems Fixed: - Concurrent Hardware and Operating System (CHAOS) Test fails in XE-10x 10G - Windows FC driver bug with Data Domain virtual tape library
Device Driver Version: 2.74.016.001 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Cleaned up a variety of corner case issues to avoid BSODs - Fixed IOCTL encounter bug-chk on BE3 during NPIV tests - Fixed reporting incorrect error code when creating vport on a switch without NPIV supported - Updated the default model name for 10Gb CNAs and 16G HBAs
Device Driver Version: 2.74.009.001 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Clean up non-critical legacy FC and uCNA incompatibilities - LUN masking doesn't persist after reboot - Emulex GUI crashes when closing a running Upgrade utility and re-open it in 802.3 configuration with IP or MAC - Several bugs related to creation or deletion of vports
Incremental Interoperability: - Windows 2012 - Improved debug capabilities - Tighter integration with MS Windows Design Kit
Device Driver Version: 2.70.018 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Fixed sending ABTS continuously to Flogi issue - Fixed reset and link bounce issues for SLI4 FC public loop - Added support for ABTS timeout handling for both SLI3 and SLI4 - Fixed loopback test incorrectly dropping the loopback frame in SLI4 - Fixed exchange management issue in SLI4 CT receive path causing array overflow - Fixed firmware version update issue following download in link up state - Fixed problem in init_vfi completion handler that stalled fabric login on BE FCoE FW - Fixed problem that caused OCM ELS Echo Test to fail - Fixed the loopback test issue in recovering from error condition - Add persistent link down support for SLI4 FC - Fix DFC_IssueDumpMBox to manage request type 3 which includes link select option - Modified reinitialization sequence following reset to fix discovery failure post type 1 or type 3 reset - Fixed new firmware dump issue
16.02.2014.0811 - Moderate Impact/Low Probability of Occurrenc (Suggested) ---------------- Fixes: - Fixed an issue where TUR Passthru fails for commands with a data length of 0. - Fixed an issue where SATA read log page data was corrupted on SWR. - Fixed an issue where running a rebuild operation on offline or failed state physical drives could not be aborted. - Fixed an issue where systems rebooted when the user selected ‘Apply’ while creating virtual drives with 512/512e/4k drives connected. - Fixed an issue where crash dump was not occurring with RAID5 installed OS. - Fixed an issue where write performance was not increased by enabling disk write cache.
15.04.2014.0225- Suggested ---------------- Enhancement: - Add hot spare support in EFI for Advanced Host Controller Interface (AHCI) systems Fixes: - Fixed an issue where the states of failed physical drives are not properly after a system reboot, when AutoResume and AutoRebuild are disabled. - Fixed an issue where locate LED were blinking during rebuild. - Fixed an issue where start init would not execute in EFI shell and displayed, "start FGI not possible". - Fixed an issue where patrol read orn R5 virtual drives does not resume after rebooting in EFI environment. - Fixed an issue where attempting to start patrol read on SSD at virtual drive level gives error message in MSM - Fixed an issue where running multiple consistency check operations in parallel results in the system becoming unresponsive. - Fixed an issue where user sees message, "Please check the configuration and retry the operation," when attempting to change controller adjustable task rates in MSM. - Fixed an issue where unconnected physical drives ports remained disabled after hibernation, keeping hot plugged devices not detectable. - Fixed an issue where when SAS and SATA drives are removed together the system hangs - Fixed an issue where elapsed time for background consistency check operations are inaccurate when the system is restarted. - Fixed the issue where Read(10) command failed when it reads with SL_SCSI_PASSTHRU to LBA (0xXX92). - Fixed an issue where 15 sec delays occur in MSM due to SoftwareRAID not presenting virtual drives with blocked access policy to the OS.
15.02.2013.1127- Suggested ---------------- Enhancement(s): - Add support for Windows Server 2012 R2. Fix(es): - Fixed an issue where Hii shows "Host Interface" value PCI_E while MSM and StorCli show PCIX.
15.02.2013.0724 - Suggested ---------------- Enhancement: - Implemented Cache policy (Read Policy and Write Policy) in Controller Management and Virtual Drive Management in HII - Added JBOD support for EFI driver
Fix: - Fixed an issue where MSM would not allow adjustable task rates to be modified a second time. - Fixed an issue where warnings were reported when code analysis was executed on Windows 2012 using MS Visual Studio 2012 RC. - Modified txtsetup.oem to reflect proper driver name megasr1.sys instead of megasr.sys - Fixed an issue where the date is showing one day ahead in EFI when compared to BIOS. - Updated device driver to continue to kick start the rebuild process, after a rebuild is started from the OS and the system is rebooted before completion of the rebuild, even when auto-resume is disabled on the controller. - Fixed an issue where the "Host Interface" value is inconsistent in Hii as compared to other tools. - Fixed an issue where chkinf may not display all active events. - Fixed an issue where after switching RAID to non RAID, options for RAID Storage settings are still displayed and gives the end user options to perform RAID operations. - Fixed an issue where Storcli hangs with execution of unsupported command-cacheflush. - Fixed an issue where OEM parameters are not getting populated correctly when the system is in RAID mode. - Fixed an issue where R5 VD PR resume was not working if system rebooted via EFI environment. - Fixed an issue where virtual drive properties are able to be set. - Fixed an issue where unsupported commands execute with improper output status as successful. - Fixed an issue where media error is getting detected even after 100% completion of consistency check. - Fixed an issue where the state of failed physical drives are not correctly shown when AutoResume and AutoRebuild are disabled and system is rebooted. - Fixed an issue where attempts to start patrol read on SSD at virtual disk level gives error message in MSM. - Fixed an issue where system cannot boot EFI install OS from 3TB PD. - Fixed an issue where patrol read is not starting on global hotspares.
15.01.2013.0115 - Suggested ------------------------------- Fix: - Fixed an issue where patrol read not starting on global hotspares.
Version 15.0.329.2012 - Initial release ---------------------
ibm_dd_megasr_18_01_2017_0105_windows_32-64_chg
Integrated Management Module II (IMM2) Firmware Update Change History
Version 7.40, 1AOO90B - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2019-11477, CVE-2019-11478, CVE-2019-11479 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2018-15473, CVE-2018-15919
Version 7.20, 1AOO88B - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2018-0737, CVE-2019-6157 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2015-5180, CVE-2018-11236, CVE-2018-15804 - Additional firmware changes in Service Data Log (FFDC) to stop from collecting the certificate and the private key of WS-MAN with hardware inventory
Version 7.00, 1AOO86D - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2018-1000120, CVE-2018-1000121, CVE-2018-1000122, CVE-2018-1000301, CVE-2018-14404, CVE-2018-15473, CVE-2018-9068 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2017-17833, CVE-2018-0732, CVE-2008-1483, CVE-2016-10012, CVE-2016-10708, CVE-2017-15906 - Fixed a problem where a false PCIE error event message may arise when powering off the system. - Fixed a problem where the system may fail to post after using LXCA to update UEFI and IMM.
Version 6.81, 1AOO84D - Critical - Supports systems: x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4 - Fixed a problem where Call Home may fail due to CA certificate change in the support website.
Version 6.80, 1AOO84C - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2018-7182, CVE-2018-7183, CVE-2018-7184, CVE-2018-7185 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2017-3145, CVE-2017-13733, CVE-2016-7141, CVE-2018-1000007, CVE-2017-3144, CVE-2017-12132, CVE-2017-8804, CVE-2018-1000001, CVE-2018-6485, CVE-2018-6551, CVE-2018-1000001, CVE-2018-5344, CVE-2016-10396, CVE-2016-5131, CVE-2017-15412, CVE-2017-16932, CVE-2017-5130, CVE-2016-5732, CVE-2018-5733, CVE-2017-12133, CVE-2016-1549, CVE-2018-7170, CVE-2017-14062
Version 6.60, 1AOO82E - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2016-4912, CVE-2012-4428, CVE-2015-5177, CVE-2016-7567, CVE-2017-15670, CVE-2017-15671, CVE-2017-17712, CVE-2017-16932, CVE-2017-16931 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2017-8872, CVE-2017-1000100, CVE-2017-11185, CVE-2016-6210, CVE-2016-10009, CVE-2016-10011, CVE-2017-1000254, CVE-2017-13728, CVE-2017-13729, CVE-2017-13730, CVE-2017-13731, CVE-2017-13732, CVE-2017-13733, CVE-2017-16879, CVE 2011-5320, CVE-2012-6701, CVE-2016-5244, CVE-2011-3637, CVE-2011-1479, CVE-2016-3070, CVE-2011-1160, CVE-2010-3877, CVE-2017-3735 - Fixed a problem on X3950 X6 where the Upper Node and Lower Node do not show correct UEFI version after the UEFI firmware is flashed. - Fixed a problem where LXCA Bare metal update process times out on system attached to SAN.
Version 6.40, 1AOO80G - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2017-11176, CVE-2013-4345, CVE-2016-6515, CVE-2017-7526, CVE-2011-2699, CVE-2015-5366, CVE-2017-14106 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2016-9131, CVE-2016-9147, CVE-2016-9444, CVE-2017-0663, CVE-2017-5969, CVE-2017-7375, CVE-2017-7376, CVE-2017-7526, CVE-2017-3142, CVE-2017-3143, CVE-2017-1000366, CVE-2016-9318, CVE-2017-9047, CVE-2017-9048, CVE-2017-9049, CVE-2017-9050, CVE-2017-9022, CVE-2017-9023, CVE-2013-4520, CVE-2015-7995, CVE-2015-9019, CVE-2016-4738, CVE-2017-5029, CVE-2016-2775, CVE-2016-6170, CVE-2017-3136, CVE-2017-3137, CVE-2017-3138, CVE-2016-9586, CVE-2017-7407, CVE-2016-9042, CVE-2017-6451, CVE-2017-6458, CVE-2017-6460, CVE-2017-6462, CVE-2017-6463, CVE-2017-6464, CVE-2015-8540, CVE-2016-10087 - Added support to send SysRq via SSH CLI. - Added a parameter to the clearlog CLI command to specify which log to clear (event log or audit log). - Changed the default minimum TLS version to TLS 1.2. Note: The firmware will continue to use the current minimum TLS version setting until the IMM2 is reset to factory defaults. Users can configure the IMM2 to use other TLS versions if needed by their browser or management application, but the default minimum is version 1.2. - Fixed a problem where SOL connection hangs randomly. - Fixed a problem where IMM web UI displays abnormal icon (x) Led status. - Fixed a problem where after updating UEFI firmware IMM shows the pending version in table instead of the previous version. - Fixed a problem where IMM auto promotion may not work. - Fixed a problem where IMM reports false PSU fan and thermal fault error message - Updated manifest to enable SKLM/TKLM on x440 M4, x240 M4, x220 M4. - Handled the false PDB (Power Distribution Board) alerts on x3500 M4.
Version 6.20, 1AOO78J - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2016-8616, CVE-2016-8617, CVE-2016-8619, CVE-2016-8624, CVE-2016-7431, CVE-2016-7433, CVE-2016-9318, CVE-2017-6214, CVE-2017-3744 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2016-9840, CVE-2016-9841, CVE-2016-9842, CVE-2016-9843, CVE-2016-8610, CVE-2017-3731, CVE-2016-8864, CVE-2016-2776, CVE-2016-7167, CVE-2016-8615, CVE-2016-8618, CVE-2016-8621, CVE-2016-8623, CVE-2016-5419, CVE-2016-5420, CVE-2016-7141, CVE-2016-9597, CVE-2016-4658, CVE-2015-5219, CVE-2015-8139, CVE-2015-8140, CVE-2016-7426, CVE-2016-7427, CVE-2016-7428, CVE-2016-7429, CVE-2016-7434, CVE-2016-9310, CVE-2016-9311, CVE-2015-8325 - Fixed a problem where mezzanine card critical errors may not trigger call home. - Corrected the SNMP imm.mib file to work with IBM Systems Director. - Fixed a problem where an IMM2 login failure may cause the IMM2 to restart. - Fixed a problem where the IMM2 backup bank was auto promoted to an old firmware version. - Fixed a problem where settings may be lost after updating the IMM2 firmware. - Removed the Remote Presence client Java version checking. - Fixed a problem where the LXCA update job may not succeed if the server is powered off. - Fixed a problem where the Chassis Event log may be unavailable when there is more than 1100 entries. - Fixed a problem where power supply information doesn't get updated when power redundancy is lost. - Corrected a problem that may cause the fans to run at full speed. - Added an OEM IPMI command to enable/disable the NMI button for X3650 M4. - Corrected a problem on the x3850 X6 where the system may shut down because the ambient temperature is too high. - Improved the SSH/Web/CIM authentication reliability when multiple connection requests are received.
Version 6.00, 1AOO76I - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 NOTE: Version 4.97 is now the minimum level required for the System x3100 M4. If the IMM2 on this system is running version 4.97 or newer, the IMM2 will not permit flashing firmware back to versions prior to 4.97. - Firmware changes to address security vulnerabilities: CVE-2016-3706, CVE-2016-1234, CVE-2016-2177, CVE-2016-2178, CVE-2016-6313, CVE-2016-6302, CVE-2015-2179, CVE-2016-2181, CVE-2016-6306, CVE-2015-8605 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2016-2180, CVE-2016-2182, CVE-2016-2183, CVE-2016-6304, CVE-2015-5352, CVE-2015-6563, CVE-2015-6564, CVE-2016-1908, CVE-2016-3115, CVE-2016-3075, CVE-2016-4429, CVE-2016-2774, CVE-2016-6153, CVE-2015-8872, CVE-2016-6263 CVE-2016-4804, CVE-2016-6318, CVE-2015-2059, CVE-2015-8948, CVE-2016-6261, CVE-2016-6262 - Fixed a problem that may cause an IMM2 login to fail via SSH/GUI/CIM after an access by Director Server. - Fixed a problem where a false CPU CAT error event message may be logged. - Added support for eMMC 5.0 on x3100 M5. - Fixed an IMM2 timeout when communicating with the CMM. - Improved the PSU event reporting mechanism to prevent possible false power supply alerts on the x3500 M4, x3550 M4, and x3650 M4.
Version 5.80, 1AOO74F - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2016-4448, CVE-2016-2108, CVE-2016-2107, CVE-2016-2105, CVE-2016-2106, CVE-2016-2109, CVE-2015-8806, CVE-2016-4447, CVE-2016-4449, CVE-2015-8138, CVE-2015-5185, CVE-2016-3627, CVE-2016-3705, CVE-2008-5161, CVE-2015-5012, CVE-2011-1473, CVE-2016-2842, CVE-2013-7041, CVE-2013-4242, CVE-2014-3591, CVE-2015-0837 - Additional firmware changes to address security vulnerabilities in open source packages, but for which there is no IMM2 exposure: CVE-2015-8023, CVE-2016-1285, CVE-2016-1286, CVE-2015-8629, CVE-2015-8631, CVE-2016-3119, CVE-2016-0799, CVE-2015-5300, CVE-2015-7704, CVE-2015-7705, CVE-2015-7973, CVE-2015-7974, CVE-2015-7975, CVE-2015-7976, CVE-2015-7977, CVE-2015-7978, CVE-2015-7979, CVE-2015-8139, CVE-2015-8140, CVE-2015-8158, CVE-2016-1547, CVE-2016-1548, CVE-2016-4953, CVE-2016-4954, CVE-2016-4955, CVE-2016-4956, CVE-2016-4957, CVE-2016-1762, CVE-2016-1833, CVE-2016-1834, CVE-2016-1835, CVE-2016-1837, CVE-2016-1838, CVE-2016-1839, CVE-2016-1840, CVE-2016-2073, CVE-2016-4483, CVE-2015-3238 - Fixed a problem when an LDAP user attempts to restart or flash the IMM an error message may occur. - Fixed a problem where the event "0 login failures" is shown in IMM2 event log. - Fixed a problem on the HS23 that could cause a firmware update to fail when using updateXpress to update the firmware. - Added changes to format the SMTP e-mail address in square brackets. - Added changes to address security vulnerabilities caused by Cipher Block Chaining (CBC) encryption in SSH Server. - Added OpenLDAP server support for LDAP logins that use the username as the UID where the DN (Distinguished Name) has a comma "," included. - Fixed a problem where LDAP authentication to Windows Active Directory would fail when authenticating with simply the username.
Version 5.60, 1AOO72H - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2015-5219, CVE-2015-5300, CVE-2016-0778, CVE-2015-3194, CVE-2015-3195, CVE-2015-3196, CVE-2015-7981, CVE-2015-8126, CVE-2016-0705, CVE-2016-0797, CVE-2016-0799, CVE-2015-8472, CVE-2015-8126, CVE-2015-8710, CVE-2016-0755, CVE-2015-7547, CVE-2015-8776, CVE-2015-8777, CVE-2015-8778, CVE-2015-8779 - Added support to filter out invalid drive information from the RAID controller - Fixed a problem on the x3750 M4 that causes the IMM to report a power supply mismatch fault - Fixed a problem that causes the IMM to unexpectedly reset on the x3850 X6 and x3950 X6 - Fixed a problem with the power capping settings that causes the x3850 x6 to power off - Fixed a problem that causes the configuration restore operation to fail when the system has 12 network ports. - Added changes to make the firmware more robust and avoid hang conditions. - Added changes to enhance DSA/OneCLI IPMI-LAN access.
Version 5.41, 1AOO70I - Critical - Supports systems: x3550 M4, x3650M4 - Firmware improvement to address a potential reliability issue for a voltage regulator. Not updating to this level could lead to a failed system board. Please refer to tip HT 118532.
Version 5.40, 1AOO70H - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x220, x222, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2015-7575, CVE-2016-0777, CVE-2016-0778 - Corrected a problem that prevented Lenovo XClarity Administrator from authenticating with the IMM2 - Fixed a problem on the x3850 X6 where the server unexpectedly reboots after an IMM2 reset - Fixed a problem on the x480 X6 that causes the CMM to report an 'unknown' IO connectivity status - Fixed a problem on the x3650 M4 that causes fan3 and fan4 to run at incorrect speeds - Fixed a problem that prevented the IMM2 gateway setting from being changed on the IMM2 web and in the UEFI menu. - Fixed a problem on the x3650 M4 where LDAP authentication does not work
Version 5.20, 1AOO68L - Critical - Supports systems: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4, x240, x440, x280, x480, x880 - Firmware changes to address security vulnerabilities: CVE-2013-2207, CVE-2013-4508, CVE-2013-4559, CVE-2013-4560, CVE-2014-5352, CVE-2014-5353, CVE-2014-5355, CVE-2014-8121, CVE-2014-8176, CVE-2014-9421, CVE-2014-9422, CVE-2015-1349, CVE-2015-1781, CVE-2015-1788, CVE-2015-1789, CVE-2015-1790, CVE-2015-1791, CVE-2015-1792, CVE-2015-1799, CVE-2015-3216, CVE-2015-3405, CVE-2015-4000, CVE-2015-4171, CVE-2015-4620, CVE-2015-5477, CVE-2015-5600, CVE-2015-5722 - Re-enabled the EDH cipher for the LDAP client - Fixed a problem on x3550 M4 where MSM connectivity issue on X3650 M4 and X3550 M4 with ESXi 5.5 u2 on IMM v4.97 - Fixed a problem where setting NIST800-131A mode on the web, CLI, and SNMP is inconsistent - Fixed a problem where the signed certificate status on the web and the CLI does not match - Fixed a problem on x3650 M4 where the "NvDIMM Status & Cables" sensor does not de-assert - Fixed a problem where the DIMM's Manufacturer ID information is not displayed - Fixed a problem where the password is not changed after setting the password via OneCLI - Fixed a problem where a user cannot log using LDAP Active Directory Application Mode - Fixed a problem on x3850 X6 where the IMM2 does not detect power supply faults and over-temperature conditions - Fixed a problem on x3500 M4/x3550 M4/x3650 M4/x3650 M4 HD where the IMM2 reports power supply configuration mismatch assertion and deassertion events within seconds - Re-enabled TLS1.0/TSL1.1 support for the web and WS-MAN interfaces when the IMM2 is in NIST mode - Fixed a problem on x3100 M4/x3250 M4 where there is no alert message logged when AC power is lost
Version 4.97, 1AOO66M - NonCritical - Supported Platforms: HS23, HS23E, x3100 M4, x3100 M5, x3250 M4, x3250 M5, x3300 M4, x3500 M4, x3530 M4, x3550 M4, x3630 M4, x3650 M4, x3650 M4 BD, x3650 M4 HD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4 - NOTE: To avoid possible exploits of the vulnerabilities discovered with SSLv3 encryption, support for SSLv3 has been removed from the IMM2 firmware. To access the IMM2 web interface using https, users must make use of client browser versions that support TLS1.2 encryption. Refer to RETAIN Tip H214507 for details. - After applying this firmware update all subsequent self-signed certificates are generated using SHA-2 cryptographic hashes. Certificate signing requests are also generated using SHA-2 cryptographic hashes if the IMM2 is configured to run in NIST SP 800-131A Compliance mode. - Critical Fix for x3750 M4 -- Fixed issue on missing power supply redundancy lost event - Firmware changes to address security vulnerabilities: CVE-2013-2566, CVE-2013-2877, CVE-2013-4332, CVE-2013-4854, CVE-2013-6435, CVE-2014-0191, CVE-2014-3505, CVE-2014-3506, CVE-2014-3507, CVE-2014-3508, CVE-2014-3509, CVE-2014-3510, CVE-2014-3511, CVE-2014-3513, CVE-2014-3566, CVE-2014-3567, CVE-2014-3568, CVE-2014-3569, CVE-2014-3570, CVE-2014-3571, CVE-2014-3572, CVE-2014-3634, CVE-2014-3660, CVE-2014-3683, CVE-2014-8118, CVE-2014-8275, CVE-2014-8500, CVE-2014-9293, CVE-2014-9294, CVE-2014-9295, CVE-2014-9297, CVE-2014-9298, CVE-2015-0204, CVE-2015-0205, CVE-2015-0206, CVE-2015-0235, CVE-2015-2808, CVE-2013-7423, CVE-2014-5352, CVE-2014-7817, CVE-2014-9402, CVE-2014-9421, CVE-2014-9422, CVE-2014-9423, CVE-2015-0209, CVE-2015-0286, CVE-2015-0287, CVE-2015-0288, CVE-2015-0289, CVE-2015-0292, CVE-2015-0293, CVE-2015-1472 - Fixed a problem that IMM2 unable to detect event from redundant PSU on x3250 M4 - Fixed a problem that PSU 1 and PSU 2 will show changed after hot swap on x3250 M4 - Fixed a problem that FAN will rotate in high speed when booting on 3100 M4 - Fixed a problem that IMM2 LDAP connects to AD server three time simultaneously for each login attempts with wrong password - Fixed a problem that Fan operates abnormally in S5 mode after rebooting system on x3550 M4 - Fixed a problem that "ipmitool chassis status" reporting false drive fault on System x3650 M4 - Fixed a problem that IMM firmware version 4.56 display as 4.55 in DSA log and UEFI data - Fixed a problem that IMM2 cannot log events on x3550 M4 - Fixed a problem that IMM2 may reset due to potential memory leakage - Fixed a problem that failure to send the alert of IMM2 via e-mail - Fixed a problem on IBM NeXtScale nx360 M4 for where the IMM may intermittently report an incorrect DC value to IBM NeXtScale n1200 Fan and Power Control (FPC) - Fixed a problem on NI152 x3650M4 where the IMM may report a power supply configuration mismatch error message in the system event log
Version 4.90, 1AOO66O - NonCritical - Firmware changes to address security vulnerabilities: CVE-2013-2566, CVE-2013-2877, CVE-2013-4332, CVE-2013-4854, CVE-2013-6435, CVE-2014-0191, CVE-2014-3505, CVE-2014-3506, CVE-2014-3507, CVE-2014-3508, CVE-2014-3509, CVE-2014-3510, CVE-2014-3511, CVE-2014-3513, CVE-2014-3566, CVE-2014-3567, CVE-2014-3568, CVE-2014-3569, CVE-2014-3570, CVE-2014-3571, CVE-2014-3572, CVE-2014-3634, CVE-2014-3660, CVE-2014-3683, CVE-2014-8118, CVE-2014-8275, CVE-2014-8500, CVE-2014-9293, CVE-2014-9294, CVE-2014-9295, CVE-2014-9297, CVE-2014-9298, CVE-2015-0204, CVE-2015-0205, CVE-2015-0206, CVE-2015-0235, CVE-2015-2808 - Fixed a problem that IMM firmware version 4.56 displays as 4.55 in DSA log and UEFI data. - Fixed a problem that IMM2 may reset due to a potential memory leakage. - Fixed a cooling issue when the Fusion IO adapter is present - Fixed a problem where the IMM2 LDAP authentication attempts to connect to an AD server three times simultaneously for each login attempt with a wrong password. - Fixed a problem that may cause the IMM2 to fail to send an alert via e-mail. - To support new security requirements the IMM firmware now requires the Java remote presence client to be at version 1.8 or newer
Version 4.80, 1AOO64T - NonCritical - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - Fixed potential problem where Service Advisor not functional when routing through a proxy server
Version 4.61, 1AOO64Y - NonCritical - Fixed a problem on IBM NeXtScale nx360 M4 for intermittent IPMB IO error and ME error. - Fixed a problem on IBM NeXtScale nx360 M4 for unexpected shutdown due to CPU over temperature
Version 4.58, 1AOO64V - Critical - Critical Fix for x3630 M4, x3530 M4, x3300 M4, x3650 M4 BD -- Removed an incorrect error message sometimes displayed when certain RAID adapters are installed in certain PCIe slots
Version 4.56, 1AOO64S - Critical - Critical Fix for x3650 M4, x3650 M4 HD, x3650 M4 BD, x3500 M4, x3630 M4, x3530 M4, x3300 M4 -- Fixed issue on missing power supply redundancy lost event
Version 4.55, 1AOO64N - NonCritical - Firmware changes to address security vulnerabilities: CVE-2014-3508, CVE-2014-3509, CVE-2014-3505, CVE-2014-3506, CVE-2014-3507, CVE-2014-3510, CVE-2014-3511, CVE-2013-2174, CVE-2013-4545, CVE-2014-0015, CVE-2014-0138, CVE-2014-0139, CVE-2014-2653, CVE-2014-2532 - Closed network port 121. - Fixed a problem of I2C error on x3500 M4 systems with use of Fairmont Raid card with FW version 23.22.0-0024 and IMM 1AOO58T - Thermal behavior enhancement on System x iDataPlex dx360 M4 - Fixed a problem that Call Home function was not working with a Proxy server
Version 4.50, 1AOO64L - NonCritical - Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-3509, CVE-2014-3506, CVE-2014-3507, CVE-2014-3505, CVE-2014-3508, CVE-2014-3510, CVE-2014-3511, CVE-2013-2174, CVE-2013-4545, CVE-2014-0015, CVE-2014-0138, CVE-2014-0139, CVE-2014-2653, CVE-2014-2532 - Fixed a problem where an erroneous event could be logged for an expansion card that would be followed by a recovery message several seconds later. - Fixed an issue with the web interface that could show a firmware update has failed if the user leaves the web interface inactive for over 20 minutes after downloading the update file. - Corrected an issue that might cause erroneous faults to be reported for the ServeRAID M5115 SAS/SATA when the server power is off. - Fixed an issue for multinode partition capable systems where when switching between partition and stand-alone modes repeatedly while also powering the nodes on and off, the IMM2 mode information could get out of sync with the server.
Version 4.35, 1AOO62W - Refresh Release - Support for refresh of the System x3650 M4 BD, Machine Type: 5466
Version 4.31, 1AOO58T - Critical - Critical Fix for x3650M4, x3550M4, x3500M4, dx360M4, x3100 M4, x3250m4, x3750M4, x3650M4 HD, x3630M4, x3530M4, x3300M4, x3250M5 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198 - Added option to export the certificate signing request in PEM format - Various Remote Presence enhancements including: -- Support for a MAC OS-x client -- Scaled video viewer window -- ASU set up of Remote Presence hot keys -- Virtual media mounting via URL - Removed potentially sensitive information from the service data file - Fixed a problem on x3650 M4, x3550 M4, x3500 M4, x3650 M4 HD where the IMM2 may not detect a loss of power supply redundancy - Fixed a problem where the LDAP group filter does not support a full DN - Fixed a problem where the syslog alert fields "Msg Type" and "Severity" did not follow RFC 5424 - Fixed a problem where the IMM2 only supported the default network port for syslog notifications - Fixed a problem where the SNMP "sysName" query always returns the string "SNMP Service" instead of the system name - Fixed a problem where the Global Login Settings changes were lost after an IMM2 restart
Important: Before you flash the IMM2 firmware back to version 3.82 or older, set the IMM2 Security option to use the Basic Compatibility Mode. This will prevent a possible loss of access to the IMM2.
Version 4.23, 1AOO62Z - Initial Release - Adds support for System x880 X6, Machine Type: 4259, 7903
Version 4.21, 1AOO58U - NonCritical - Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 4.20, 1AOO58R - NonCritical - Fixed an issue in I2C communications that could cause CMM to report, "FPGA Host 2 Communication is offline" - Fixed a problem that required the browser cache to be cleared before accessing IMM2 web page. - Corrected a problem that caused the CMM to reporting an I/O connectivity problem with the FSM - Enhanced the IMM2 service and support data to better aid in the diagnosis of VPD issues - Added support for the S3 system sleep state - Added support for agentless monitoring of PCIe devices - Enabled a Flex compute node to be powered on sooner after installation in the chassis - Added RFC compliance checking for user input - Ensured consistency in Daylight Savings Time setting between the CMM and IMM2 - Added support for enhanced hard drive monitoring and status - Corrected an issue that caused false reports of incorrect / missing / corrupt VPD events.
Version 4.15, 1AOO58K - Suggested - Added support for the BIE (Blade IO Expansion Board) on the HS23, HS23E - Fixed a problem that prevented the AMM from controlling power when local power control is disabled on the HS23, HS23E
Version 4.10, 1AOO58F - Initial Release - Supports System x3100 M5, Machine Type: 5457
Version 4.04, 1AOO64E - NonCritical - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - Fixed potential problem where Memory Details on Critical DIMM points to a different location - Fixed potential problem for power state mismatching when one node transitions from AC disconnected to AC connected while the other node is powered up
Version 4.02, 1AOO58S - NonCritical - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - Fixed a potential problem where a single CPU and single Power Supply model may show a configuration error - Fixed a potential problem where fans running at high speed under normal operation may erroneously log a fan failure - Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198 - Fixed a power state change problem when removing a Compute book with an I/O book attached - Fixed a problem where PCIE adapters in I/O books may not show up after an OS reboot
Version 4.00, 1AOO58I - NonCritical - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - Add Scalable support. - x3950 X6 initial GA support level - Add support for enhanced hard drive monitoring and status - Fixed a potential problem that may cause the IMM to reboot in a configuration with multiple single port network cards.
Version 3.91, 1AOO58G - Critical - Supports System x3750 M4, Machine Type: 8752, 8718 - Add a feature to allow users to block power control from the power button on the x3750M4
Version 3.90, 1AOO54X - NonCritical - Added support for the IBM NeXtScale PCIe Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.86, 1AOO56V - Critical - Critical Fix for x3500 M4 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 3.85, 1AOO56U - Critical - Critical Fix for x220, x222, x240, x440, Flex System Manager Node -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 3.84, 1AOO56J - Critical - Critical Fix for x3300 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.83, 1AOO56I - Critical - Critical Fix for x3250 M5, nx360 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.82, 1AOO56E - Critical - Critical Fix for x3850 X6 / x3950 X6 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.81, 1AOO52Z - Critical - Critical fix: -- Corrected the x3850/x3950 x6 server to turn off power from the power supplies when a power fault occurs
Version 3.80, 1AOO52U - Initial Release - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - up to 4 CPU in one system - x3850 X6 initial GA support level
Version 3.79, 1AOO56G - Critical - Critical Fix for x240, x222, x440, x220, Flex System Manager Node -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.78, 1AOO52Y - Critical - Critical Fixes: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a potential security vulnerability with Trusted Platform Module (TPM) initialization settings (refer to security bulletin CVE-2014-0881)
Version 3.77, 1AOO56H - Critical - Critical Fix for x3630 M4, x3530 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.76, 1AOO56Q - Critical - Critical Fix for x3650 M4 BD -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 3.75, 1AOO56F - Critical - Critical Fix for x3650 M4 BD -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.74, 1AOO52R - Critical - Critical Fix: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.73, 1AOO56D - Critical - Critical Fix for: dx360 M4, x3650 M4, x3550 M4, x3500 M4, x3100 M4, x3250 M4, x3750 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.71, 1AOO52W - Critical - Critical Fix for x3550 M4: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a problem system may shut down with new Mezz card installed
Version 3.70, 1AOO52Q - Critical - Critical Fix: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882)
Version 3.67, 1AOO50G - Initial Release - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.65, 1AOO50D - Suggested NOTE: If you have a System x3550 M4 with the "Emulex VFA Mezz card" and a ==== single processor, don't update the IMM2 with this firmware - Critical Fix: -- Fixed a problem on the System x3650 M4 server where the system shuts down due to a false temperature event from the ambient temperature sensor - Fixed a problem where the IMM2 may erroneously report a fan fault in the x3630 M4 when the system is powering on. See RETAIN tip H207461 for the description of the original problem - Fixed a screen refresh problem where it occurs after resetting IMM2 - Fixed a firmware problem that may cause the IMM2 to reset unexpectedly - Fixed a problem where the IMM2 SNMP interface may intermittently be unavailable if the system is running VMWARE ESXi 5.x - Fixed a problem where the CPU may potentially throttle in the x3650 M4 system with two 550 watt power supplies and one hard drive backplane
Version 3.60, 1AOO50C - Suggested - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM - Corrected a problem that caused the IMM to report an "Unsupported blade/blower combination" error on HS23
Version 3.56, 1AOO50K - Critical - Fixed a Flex Systems Manager (FSM) Configuration Patterns problem where configuration deployments would fail with an activation job error message: ERROR: LDAP failed with rc=102 ERROR: LDAP failure: SYSPROF_LDAP_BIND_FAIL INFO
Version 3.55, 1AOO50E - Suggested - Fixed an issue so a fully qualified domain name can be used for a syslog collector in addition to an IP address - Fixed an issue to allow a user the ability to specify the port to use for syslog notifications, rather than only supporting the default port
Version 3.50, 1AOO50B - Suggested - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Initial Release - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Suggested - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Critical - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.35, 1AOO48N - Critical - Critical Fix: -- Corrected a problem on the System x3650 M4 and x3650 M4 HD servers causing the system to shut down due to an erroneous critical temperature event reported by the ambient temperature sensor
Version 3.30, 1AOO48L - NonCritical - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Initial Release - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - NonCritical - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.62, 1AOO56T - Critical - Critical Fix for x220, x222, x240, x440, Flex System Manager Node -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 2.61, 1AOO44V - Critical - Critical Fix for x240, x220, x440, x222, Flex System Manager Node -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 2.60, 1AOO42Y - NonCritical NOTE: For increased security, only high strength ciphers are now supported when using https.
==== Your browser must support one of the following cipher suites: | DHE-RSA-AES256-SHA256 TLSv1.2 Kx=DH Au=RSA Enc=AES(256) Mac=SHA256 DHE-RSA-AES256-SHA SSLv3 Kx=DH Au=RSA Enc=AES(256) Mac=SHA1 AES256-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA256 AES256-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA1 DHE-RSA-AES128-SHA256 TLSv1.2 Kx=DH Au=RSA Enc=AES(128) Mac=SHA256 DHE-RSA-AES128-SHA SSLv3 Kx=DH Au=RSA Enc=AES(128) Mac=SHA1 AES128-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA256 AES128-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA1
- Added support for the IBM Flex System x222 Compute Node - Improved Remote Presence (keyboard, mouse and virtual media)and in-band management (LAN-over-USB) performance - Changed the default file name for the Service Data file (First Failure Data Capture or FFDC) on the web interface to incorporate the machine type, serial number and a timestamp - Updated the IMM2 PCIe Bridge Firmware to support Windows 2012 Certification - Improved IMM2 Reliability, Availability, Serviceability (RAS) Features: - Added component and system VPD integrity checking & reporting - Enhanced Service Data collection (FFDC)
- Enhanced the configuration of UEFI settings via the CIM interface for applications like IBM Systems Director - Added Sub-manufacturer inventory support for mezz card and Sub-manufacturer inventory support for the system for IBM Systems Director - Added the UUID for the PCIe Expansion Node and the Storage Expansion Node to the SLP attributes reported by the IMM2 - Added the number of enabled CPU core and the Static power savings mode support for IBM Systems Director - Enhanced the alert recipient email notification, firmware update, event log, log out, and hardware information web pages to improve usability - Added support for IPMI & SNMPv3 accounts to be centrally managed by the Flex Chassis Management Module - Fixed a problem where an invalid configuration was erroneously reported for an unpopulated CPU socket in the IBM Flex System x440 - Enabled users to configure a longer trespass message - Increased the length of the LDAP group filter field to 511 characters - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems energy pack monitoring - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems LED management - Added IPMI command to configure the LAN-over-USB IP address
Version 2.52, 1AOO42E - Critical - Critical Fix: -- Fixed a problem on the System x3300 M4 servers causing the system to shut down due to a critical temperature event reported by the ambient temperature sensor
Version 2.50, 1AOO40Z - Suggested - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.06, 1AOO42B - Critical - Corrected the firmware to prevent users from disabling the IPv6 interface - Fixed a problem that caused the IMM2 to reset itself after running for a period of time - Corrected the SNMP request to disable the IMM2 IPv4 interface so that it disables only IPV4, instead of both IPv4 and IPv6 - Fixed a problem that occasionally caused the server to shut down when the IMM2 is reset - Fixed a problem where the IMM2 incorrectly reported a battery voltage error - Corrected a problem where repeated frequent IMM2 resets causes the IMM2 to run the firmware in its backup partition - Corrected a problem report where the IMM2 did not report a failure to the system profiles script when the chassis UUID is unavailable
Version 2.00, 1AOO40E - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1AOO34Z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Suggested - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
IMPORTANT NOTICE: For X3300 M4, it is required to upgrade both the primary and backup IMM2 firmware to Version 1.86, 1AOO40D or later. After the IMM2 is successfully updated, it is highly recommended to run the following IPMI command: Get device id (ipmitool raw 6 1) If the last two bytes returned show 0x2A 0x41 even after a reset of the IMM2, please refer to TDR-H207183 or MIGR-5092140 for more information.
Version 1.86, 1AOO40D - Critical - Critical Fix: -- Fixed a problem where the X3300 M4 system configured with a M5110/M5120 RAID card plus the "IBM ServeRAID M5100 Series 512MB/1 gigabytes (GB) Flash/RAID 5 Upgrade for IBM System x" option might have problem if AC power is removed while the system is running
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Initial Release - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Suggested - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Suggested - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Critical - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Suggested - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Suggested - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Suggested - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Initial Release - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Critical - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Suggested - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Critical - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Suggested - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - NonCritical - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Initial Release - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Initial Release - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Initial Release - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Initial Release - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Critical - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.26, 1AOO26N - Initial Release - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Initial Release - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Suggested - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Initial Release - Supports System HS23, Machine Types: 7875,1929
Version 1.05, 1AOO10K - Initial Release - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2020. All rights reserved.
ibm_fw_imm2_1aoo92a-7_60_anyos_noarch_chg
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.22.01 Build ID: IBM12201 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.22.01 - Update Utility release for IBM x86 servers.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.22.00 Build ID: IBM12200 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.22.00 - Update Utility release for IBM x86 servers.
Note: *- Only keep the legacy HDD/SSD in this Update program, the drives were out of production by 4Q2014 or no firmware changes since 1Q2014. No FW update for below legacy drives in this version.
This package acknowledges support and may include updates for drives with product ID strings of:
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.21.00 Build ID: IBM12100 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.21.00 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5K
- ST2000NM0043, ST4000NM0043 to EC5H
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6E
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC6E
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to MPXSJ3LA
- HUS724020ALS61, HUS724040ALS61 to MPXSN3LA
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to VCXSA810
SAS 2.5"
- HUC156030CSS20, HUC156060CSS20 to KFXSJ2G8
- HUC101212CSS60 to CPXSJ2MC
- HUC101212CSS61 to CPXSN2MC
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to CEXSJ2EL
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to CEXSN2EL
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to SPXSJ4CC
- HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to SPXSN4CC
SATA 3.5"
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD40
- ST2000NM0024, ST4000NM0024, ST6000NM0024, ST5000NM0024 to BB67
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5G
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB47
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA35
- STECM8PSB2 to 2864/SM08
SATA 1.8"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB47
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.20.00 Build ID: IBM12000 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.20.00 - Update Utility release for IBM x86 servers.
Note: *- Update the firmware on SAS/SATA SSDs to fix PSIRT issue with Intel SSD's.
This package acknowledges support and may include updates for drives with product ID strings of:
SATA 2.5"
- SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB480G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA39.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC34.
SATA 1.8"
- SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to D201NE40.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.19.06 Build ID: IBM11906 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.19.06 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
- Remove TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I from FW update utility for new code updating break Raid.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.18.03 Build ID: IBM11803
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.18.03 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read.
RETAIN TIP: H214635 MIGR-5098037
SAS 3.5"
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6B - similar to Note * above.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5J - Enhance Dither Algorithm to prevent dwelling during Idle environments. - ST2000NM0043, ST4000NM0043 to EC5E - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SAS 2.5"
- TXA2E21600GA6I to GB7P - add support in profile.
- HUC156030CSS20, HUC156060CSS20 to J2G6 - add support in profile.
SATA 3.5"
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB68 - similar to Note * above.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5F - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SATA 2.5"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB42 - add support in profile.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I to D201NB39 - add support in profile.
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read. RETAIN TIP: H214635 MIGR-5098037
This package acknowledges support of qualified devices and may include updates for drives with product ID strings of:
SAS 3.5"
- HUS724020ALS61, HUS724040ALS61 to N3L6 - internal updates.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5H - See Note * above.
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC66 - see Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- Other drive codes are present for support identification.
SAS 2.5"
- WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA34 - follow-on release. - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC33 - follow-on release.
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EH - follow-on release.
- TXA2D20200GA6I, STXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I to GB7P - enhancements.
- ST300MM0006, ST600MM0006, ST900MM0006 to B56T - See Note * above.
- ST300MM0026, ST600MM0026, ST900MM0026 to E56E - See Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- ST1200MM0007 to B57E - See Note * above.
- ST1200MM0017 to E577 - See Note * above.
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to J4C8 - See Note # above - HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to N4C8 - See Note # above
- Other drive codes are present for support identification.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1D - performance inhancements.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5C - See Note * above.
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB65 - See Note * above.
- WD2003FYYS-23W0B0 to WA36 - configuration additions.
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD39 - configuration additions.
- HUA723030ALA6 to MKAOA930 - enhancements. - HUA723020ALA6 to MK7OA930 - enhancements.
- Other drive codes are present for support identification.
SATA 2.5"
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA34 - ship level.
- Other drive codes are present for support identification.
SATA 1.8"
- Drive codes are present for support identification.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.05 Build ID: IBM11605
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.05 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4B - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L6 - Fixed unexpected 02/04/11 error; Fixed a drive logic self-initiated reset on read/write long commands; Fixed a problem with large write sequential transfers.
SAS 2.5"
- ESXSST9500620SS, ESXSST91000640SS to BD2K - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
SATA 2.5"
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.04 Build ID: IBM11604
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.04 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB42 - > A drop in host power supply may cause bad block growth > The bad block table may not properly increment > Background activity may continue after STANDBY, STANDBY IMMEDIATE, or SLEEP > ID173/202 may show incorrect value when the NAND erase count exceeds 3000 > Changed DRAM timing > Event log may be programmed when supply voltage from host is out of specification
- SSDSC2BB012I4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix that corrects a condition that may cause the drive to not respond.
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND34 - will require two update runs and system reboots for device fw update to complete--Please See the limitations in readme for details.
> Performance improvement on sub-4KB sequential write > Fix drive reports higher than actual data units read and write > Fix drive incorrectly counts unsafe power shutdown events on warm reboots
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.03 Build ID: SAS11603
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.03 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST2000NM0034, ESXSST4000NM0034, ESXSST6000NM0034 to BC67 - GA code. - ESXSST2000NM0054, ESXSST4000NM0054, ESXSST6000NM0054 to EC66 - GA code.
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA39 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SAS 2.5"
- ESXSTXA2D20200GA6, ESXSTXA2D20400GA6, ESXSTXA2D20800GA6, ESXSTXA2E21600GA6 to GB7P - fixes implemented to support PI issues.
- ESXSST300MP0005 to B675 - GA code. - ESXSST300MP0025 to E671 - GA code.
- ESXSST300MP0035, ESXSST600MP0035 to B683 - GA code. - ESXSST300MP0045, ESXSST300MP0045 to E685 - GA code.
- ESXSST300MX0012, ESXSST600MX0052 to BH53 - GA code.
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23DS to ZA34 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; drive was reporting 0B/11 instead of 03/11. - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC33 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1C - GA code
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE2B - Update configuration change.
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB34 - > Some Out of Range LBAs accepted by NCQ commands where they should be aborted. > SataDownShift.srt failed, Smart attribute Raw lost with perform dirty pwr cycle . > Low Power Entry Bug Identified from Marvell Code Review > Track Timeout, Marvel 373 sequencer issue > Unreasonable ECC count in SMART ID 195
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program for Linux. Version 1.16.00 Build ID: SAS11600
******************************************* IBM SAS/SATA HDD/SSD Update Program Version 1.16.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37 - Resolves drive initiated reset (DBS (Debug Stop event)) encountered under a narrow timing window (~1ns) for specific command/access patterns, due to the drive’s handling of command automation where it was possible for an internal hardware resource conflict to occur between two tasks.
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NSto BE2A
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA37
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND32 - will require a system reboot for device fw update to complete.
********************************************************************* SAS/SATA HDD/SSD Update Program Version 1.15.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37
- ST9500620NS, ST91000640NS to BE2A
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9500620NS, ST91000640NS
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA36
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
NOTE TO SERVICE - Reference RETAIN TIP H29851 ******************************************* SAS Hard Disk Drive Update Program Version 1.14.04 Critical Release Reference RETAIN TIP H29851
This package includes updates to drives with product ID strings of:
SAS 2.5"
Initial code Release - SMK3001GRDB, SMK6001GRDB, SMK9001GRDB to SB35
SATA 2.5"
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA36 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB37 - fix to prevent possible drive lock up during format.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA36 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB37 - fix to prevent possible drive lock up during format.
=================================================================== IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to E568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX ibm_fw_hddlegacy_sas-1_22_01_windows_32-64_chg
This release contains the following software programs:
NetXtreme Gigabit Ethernet NDIS6.x for Microsoft Windows 2008/2012/2012R2, 32 bit extensions - b57nd60x.sys NetXtreme Gigabit Ethernet NDIS6.x for Microsoft Windows 2008/2012/2012R2, 64 bit extensions - b57nd60a.sys
* Third-party trademarks and copyrights are the property of their respective owners.
Broadcom, Broadcom Advanced Server Program, Broadcom Advanced Server Control Suite, and Smart Load Balance are registered trademarks of Broadcom Corporation.
brcm_dd_nic_17_2_0_2_windows_32-64_chg
Dynamic System Analysis (DSA) Preboot Change History
Version 9.54, Build ID DSYTD8G o Enhancement: 1. Embedded DSAp Simplification by removing Low-Value Functionality - Inventory: BIST,PMC - Diags: RSARST Diags, Tape Drive Diags, Optical Drive Diags,Check point (LED) Panel Diags 2. Heartbeat for F2 standalone memory test. 3. IBM High IOPS Adapter Raw Data Collection. 4. pDSA Simplification for FoD Function & GUI Client. 5. Add warning & report in client for nonsupport systems. 6. Change sFTP as the default protocol for transfer log to IBM Service. 7. Get standalone memory test results & SOL support for DSAp(for security efi boot). 8. Update openssl to 1.0.1h from 1.0.1g. o Limitations: 1. After finish run all diagnostics in 25 loop with Emulex 10G options, DSA log will show abnormal, it only record Diags log one time on DSA Diagnostics Completion Log. 2. On GUI, when two ports of the machine want to connect the Extranet at the same time, the machine could not send dsa log to IBM server. you can click test internet connection to solve the problem. 3. System not show event log item in chassis event log & ipmi event log page when trigger SBE in standalone mode. o Special usage: - 2014 IMMV2 2QLFC Product Build
Version 9.43, Build ID DSYTC8E o Enhancement: 1. Preboot GUI redesign and enhancement--refine GUI into more customer friendly style. 2. FoD Support--FoD key re-activation. 3. pDSA proxy auto-config retrieve. o Limitations: 1. DSA Does not support "VMware ESXi" page report for ESXi 5.x key due to "vmvisor-offline-query" limitaion . o Special usage: - 2013 IMMV2 4QLFC
Version 9.33, Build ID DSYTB6E o Limitations: When we want to flash from B5E to B6E, we should level down to AA3 or AA4 first.
Version 9.30, Build ID DSYTB27 o New System Support: Flex System x440 Compute Node (7917, 2584) IBM System x3300 M4 (7382) o Problem(s) Fixed: 1. PMR - 05766,YL2,760 Aenservice appeared after running UpdateXpress & DSA. 2. PMR - 05193,W01,000 7147 - Intermittent random PSOD in vmware. multiple
o Enhancement: None o Limitations: - FIFO test of NIC diagnostics is not supported on the Intel I350 Quad Port GbE. Powerville has shared FIFO and shared FIFO registers making a test impossible if four ports are running at once. - For more limitations please refer to readme. o Special usage: - 2012 ToolsCenter 12D
Version 9.29, Build ID DSYTAB6 o New System Support: Flex System x440 Compute Node (7917, 2584) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - NGP-4Q(12B+ FixPack3)
Version 9.28, Build ID DSYTAA4 o New System Support: x3630 M4 (7519) x3550 M4 (7383) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - IMMV2 system 2012 4Q-LFC
Version 9.27, Build ID DSYTA7F o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme o Special usage: - IMMv1 system 2012 4Q-LFC
Version 9.26, Build ID DSYTA6G o New System Support: None o Problem(s) Fixed: None o Enhancement: DSA Performance Optimization o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12C
Version 9.21, Build ID DSYTA1U o New System Support: None o Problem(s) Fixed: 1.Recovered LSI Rawdata: "MegaCli -FwTermLog -Dsply -aALL" o Enhancement: None o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B Plus
Version 9.20, Build ID DSYTA0R o New System Support: x3530 M4 (7160) x3630 M4 (7158) x3750 M4 (8722, 8733) HS23E (8038, 8039) Flex System x220 Compute Node (7906, 2585) o Problem(s) Fixed: 1. PMR 05819,YL2,760 An error occured during the execution of DSA on Windows, DSA exits with an error at the eventlog plugin. o Enhancement: 1. Add HW remote presence key collection for High volume systems. o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B
Version 9.07, Build ID DSYT9CA o New System Support: x3750 M4 (8722, 8733) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.06, Build ID DSYT9BC o New System Support: Flex System x220 Compute Node (7906) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.05, Build ID DSYT9AA o New System Support: x3630 M4 (7158) x3530 M4 (7160) x3100 M4 Refresh1 (2582) x3250 M4 Refresh1 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.04, Build ID DSYT99E o New System Support: Flex System x240 Compute Node (8737, 8738, 7863) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.03, Build ID DSYT98I o New System Support: HS23E (8038, 8039) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.02, Build ID DSYT97C o New System Support: iDataPlex dx360 M4 server/2U chassis (7912/7913) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.01, Build ID DSYT96D o New System Support: x3500 M4 (7383) x3550 M4 (7914) x3650 M4 (7915) o Problem(s) Fixed: o Enhancement: None o Limitations: None o Special usage: None
Version 9.00, Build ID DSYT95W o New System Support: BladeCenter HS23 (7875) BladeCenter HX5 (7873, 1910) Flex System x240 Compute Node (8737, 8738, 7863) Flex System Manager Node (8735) x3500 M4 (7383) x3550 M4 (7914) x3630 M4 (7158) x3650 M4 (7915) x3690 X5 (7192, 7147) x3850 X5 / x3950 X5 (7143, 7191) o Problem(s) Fixed: 1. PMR 24817,8QG,000, PMR 30680,499,000 After kicking off DSA on one of the management nodes (x3650 M2) of SONAS 1.2(RHEL5 based), the node became unresponsive and dropped out of the cluster.
2. PMR 53575,000,834, PMR 05961,YL4,760 After running DSA, when using linux dump command on a DDS5 usb internal tape drive attached in x3650M2 backup speed becomes very slowly or failed.
3. PMR 26905,095,866 Running DSA 4.0 as well as DSA 3.4 on x3850 X5 the server is freezing, users have to reboot the server.
4. DSA 4.00 and previous version segmentation fault issue
6. PMR 15086,OTH,760 DSA 9.00 with --no-imm-lan option does not work correctly on RHEL5.3. The USB port state is changed during the execution of DSA.
o Enhancement: 1. Add GUI and CLI menu for Features on Demand (FoD) Activation Key Management o Limitations: Refer to readme. o Special usage: None
Version 4.02, Build ID DSYT92I o New System Support: iDataPlex Direct Water Cooled dx360 M4 server o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 4.01, Build ID DSYT92H o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 4Q lifecycle
Version 4.00, Build ID DSYT91S o New System Support: None o New server options support: None o Problem(s) Fixed: 1. PMR 15065,OTR,760 On Unisys ES7000 or x3850 X5, the Memory Card number with failed DIMM can not be reported in IPMI Eventlog if the Memory Card is bigger than 4.
o Enhancement: 1. Added > 1TB memory test support o Limitations: Refer to readme. o Special usage: - 2011 ToolsCenter 11D
Version 3.48, Build ID DSYT89PUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 3Q lifecycle
Version 3.47, Build ID DSYT89LUS o New System Support: x3100 M4 (2582) x3250 M4 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.46, Build ID DSYT89GUS o New System Support: System x iDataPlex dx360 M3 (6391) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.45, Build ID DSYT89EUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - x3850 X5 / x3950 X5 (7143, 7191) EXA scaling
Version 3.43, Build ID DSYT87HUS o New System Support: BladeCenter HX5 (7873,1910) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.43, Build ID DSYT87FUS o New System Support: x3850 X5 / x3950 X5 (7143, 7191) x3690 X5 (7192, 7147) o Problem(s) Fixed: o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.40, Build ID DSYT85T o New System Support: BladeCenter HS22 (1911) x3650 M3 (5454) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.30, Build ID DSYT80S o New System Support: None o Problem(s) Fixed: None o Enhancement: 1. Correct a problem with LSI MegaRAID reporting for IBM Service o Limitations: Refer to readme. o Special usage: None
Version 3.20, Build ID DSYT75X o New System Support: x3630 M3 (7377) x3690 X5 (7148, 7149) o Problem(s) Fixed: None o Enhancement: 1. Add LSI Hard Disk Drive (HDD) diagnostic back for both the onboard SAS chip and ServeRAID o Limitations: - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Verion 3.20, Build ID DSYT75U o New System Support: x3755 M3 (7164) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Verion 3.10, Build ID DSYT70X o New System Support: x3400 M3(7378, 7379) x3500 M3(7380) x3550 M3 (7944, 4254) x3620 M3 (7376) x3650 M3 (7945, 4255) x3690 X5 (7148, 7149) x3850 X5 Standard Single-node and Multi-node models(7145, 7146) x3950 X5 Specially configured Database Engine models (7145, 7146) iDataplex dx360 M3 (6391) HS22V (7871,1949) HX5 (7872, 1909) o Problem(s) Fixed: None o Enhancement: 1. Added ServeRAID data collection o Limitations: - The following function has been temporarily removed from DSA Preboot for both the onboard SAS chip and ServeRAID: - LSI Hard Disk Drive (HDD) diagnostic - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Version 3.02.56, Build ID DSYT56e o New System Support: None o Problem(s) Fixed: None o Enhancement: - The following systems are supported when BoMC downloads the corresponding system enablement pack: HS22V (7871,1949) x3550 M3 (7944,4254) x3650 M3 (7945,4255) x3400 M3 (7378,7379) x3500 M3 (7839) dx360 M3 (6391) o Limitations: - No HDD diagnostics available - To ensure quality and stability of the DSA code, we have reverted some display functionality of RAID information to what was shown in previous versions of DSA. This affects RAID display on the following adapters: Megaraid 8480 Serveraid MR10i Serveraid MR10is Serveraid MR10m Serveraid MR10k Serveraid M1015 Serveraid M5014 Serveraid M5015 On these adapters, the RAID information is generated from the output of separate command line tools and the format may not match other output in DSA. - For more limitations please refer to readme o Special usage: None
Version 3.00, Build ID: DSYT55a o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7327, 7328, 4251, 4252, 4261 o Limitations: - No HDD diagnostics available - For more limitations please refer to readme o Special usage: None
Version 1.16, Y4YT19AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7839, 7836, 7837 o Limitations: None o Special usage: None
Version 1.15, TMYT20AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7321, 6380, 7323 o Limitations: None o Special usage: None
Version 1.14, D6YT37AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7946, 4198, 7947, 4199 o Limitations: None o Special usage: None
Version 1.13, P9YT48AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7870, 1936, 7809 o Limitations: None o Special usage: None
Version 1.00 - Initial release
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved. ibm_fw_dsa_dsytd8g-9_54_anyos_anycpu_chg
Change History
For installation instructions, see the Install Tip file which is provided in the downloaded software package. NOTE: This document is designed to be cumulative. The current version is appended to the previous version(s).
========================================================================== System: IBM x3100 M4/x3250 M4 UEFI Flash Update Version 2.10, Build ID JQE186B, Critical Release date: June/2019 ==========================================================================
Machine Types supported: 2582, 2583 Operating systems supported: Operating System Independent
-------------------------------------------------------------------------- 2.0 Prerequisites and dependencies -------------------------------------------------------------------------- None
-------------------------------------------------------------------------- 3.0 Security Fixes -------------------------------------------------------------------------- FIX: 1. Fixed an admin password issue when exiting from the Windows Boot Manager
-------------------------------------------------------------------------- 4.0 Other Fixes -------------------------------------------------------------------------- FIX: None
Version 1.90 - BuildID: JQE184CUS ---------------------------------------- Problem(s) Fixed: - Removed insecure Serial Peripheral Interface (SPI) Opcodes to address CVE-2017-5703. - Updated microcode to address security vulnerability CVE-2018-3639 and CVE-2018-3640. Enhancements: Limitations: Dependencies:
Version 1.80 - BuildID: JQE182CUS ---------------------------------------- Problem(s) Fixed: Enhancements: - Updated microcode to address CVE-2017-5715 - Update Logo(s) and Readme to 2018. Limitations: Dependencies:
Version 1.71 - BuildID: JQE180CUS ---------------------------------------- Problem(s) Fixed: - Updated microcode to address CVE-2017-5715 Enhancements: Limitations: Dependencies:
Version 1.70 - BuildID: JQE180BUS ---------------------------------------- Problem(s) Fixed: - Fixed an issue in F1 Setup when selecting "Boot from file" in the Boot Selection menu. Enhancements: Limitations: Dependencies:
Version 1.60 - BuildID: JQE178BUS ---------------------------------------- Problem(s) Fixed: - Fixed an issue using an UK keyword when setting the Admin password through Setup Enhancements: Limitations: Dependencies:
Version 1.50 - BuildID: JQE176DUS ---------------------------------------- Problem(s) Fixed: - Fixes an issue that the Event Log is not updated when Power On Password (POP) or Boot Order is changed in UEFI Setup. - Provide correct System Status when System is powering up into VMware 6.0 U2. - Fixes issue of CPU information not being correct in the LXCA-Endpoint Inventory details. Enhancements: Limitations: Dependencies:
Version 1.40 - BuildID: JQE174BUS ---------------------------------------- Problem(s) Fixed: - Remove the console-redirection option for COM2 in Setup Menu. console-redirection is not supported through the COM2 Port. Enhancements: Limitations: Dependencies:
Version 1.30 - BuildID: JQE172DUS ---------------------------------------- Problem(s) Fixed: - VMware 6.0 to install satisfactory. - LSI C100 to be able to create a RAID entry under Virtual Drive Management. Enhancements: Limitations: Dependencies:
Version 1.20 - BuildID: JQE170BUS ---------------------------------------- Problem(s) Fixed: - HII Load Form Issues (General and RAID). - Fix Crossfield HII Call Back Issue - Fix Crossfield HII Dummy Page Issue Enhancements: Limitations: Dependencies:
Version 1.09 - BuildID: JQE168BUS ---------------------------------------- Problem(s) Fixed: - Fix system fails when running UEFI Firmware Certification Test for Windows 2012 - Fix SW RAID can't be configured via uEFI on x3250 M4 - Fix uxspi can not show correct currect uefi version when flashing uefi Enhancements: Limitations: Dependencies:
Version 1.08 - BuildID: JQE166FUS ---------------------------------------- Problem(s) Fixed: - Fix unablility to configure multichannel settings on Endeavor card - Fix diag code error issue - Fix system show rubbish after setting remote console enable on VMware 5.x Enhancements: - Add limit boot feature - Add VLan ID feature - Update network package code Limitations: Dependencies:
Version 1.07 - BuildID: JQE164AUS ---------------------------------------- Problem(s) Fixed: - Fixed system will show error after disabling TPM - Fixed wrong planar ID Enhancements: Limitations: Dependencies:
Version 1.06 - BuildID: JQE160BUS ---------------------------------------- Problem(s) Fixed: - Fixed system unexpected power off with sensor planar voltage fault Enhancements: Limitations: Dependencies:
Version 1.06 - BuildID: JQE160AUS ---------------------------------------- Problem(s) Fixed: Enhancements: - Replace setVIDdecay command by setVIDslow Limitations: Dependencies:
Version 1.05 - BuildID: JQE158AUS ---------------------------------------- Problem(s) Fixed: - Fix dsalog show wrong information Enhancements: - Update Sandy Bridge D2 stepping u-code(M12206A7_00000029.TXT)Remark:For SNB D2 stepping (SRV_P_121) - Update Ivy Bridge E-1/L-1 stepping u-code (M12306A9_00000015.TXT)Remark:For IVB E-1/L-1 stepping (SRV_P_121) - Incorporated Microcode Update (MCU) M12206A7_00000029.TXT (SNB D2 stepping) and M12306A9_00000015.TXT (IVB E-1/L-1 stepping) to address Intel Erratum HSD89 for System Resets with 32-bit (PAE Enabled) Guest OS and VT FlexPriority enabled. Limitations: Dependencies:
Version 1.04 - BuildID: JQE156DUS ---------------------------------------- Problem(s) Fixed: - Fix windows 2012 legacy mode hang issue Enhancements: Limitations: Dependencies:
Version 1.04 - BuildID: JQE156CUS ---------------------------------------- Problem(s) Fixed: - Fix the issue that AC power cycle is required when downgrading uEFI from 56C to earlier version than 52F. Enhancements: Limitations: Dependencies:
Version 1.03 - BuildID: JQE152FUS ---------------------------------------- Problem(s) Fixed: - System 3x-POST failure feature does not work on OEM Builds - System can not boot to legacy OS with addon NetXtreme II 1000 Express Quad Port card - Unable to boot from USB key via IMM2 Virtual media with Remote Control - Change CPU from Sandy Bridge E3-1270 to Ivy Bridge i3 core or Pentium will cause system halt at uefi starting - Linux UEFI OS sometimes gets kernel panic while booting from F1/F12 menu Enhancements: - Hide some unnecessary items in Setup Menu - Update Ivy Bridge E-1/L-1 stepping u-code (M12306A9_00000015.TXT).Remark: For IVB E-1/L-1 stepping (DT_P_63) - Follow the System x Software Design Guide to update the string of IMM version - Support "uEFI signed UPD" feature - _WDG ACPI method support for SRIOV Limitations: Dependencies:
Version 1.02 - BuildID: JQE148AUS ---------------------------------------- Problem(s) Fixed: - Incorrect IMM2 version in uEFI menu. - H205951 System can not boot into iSCSI OS from Start Option Menu Enhancements: - Update Ivy Bridge E-1/L-1 stepping u-code (M12306A9_00000012.TXT) - Update IVB CPU RC to 1.5.0 - Update IVB SA RC 1.5.0 Limitations: Dependencies:
Version 1.01 - BuildID: JQE142CUS ---------------------------------------- Problem(s) Fixed: Enhancements: - Support RHEL 6.1 for system in production mode - Update Readme files Limitations: Dependencies:
Version 1.01 - BuildID: JQE140AUS ---------------------------------------- Problem(s) Fixed: Enhancements: - Update IVB SA RC 1.2.0 - Update IVB CPU RC to 1.2.0 - Update Ivy Bridge E-0/E-1 & L-0/L-1 stepping u-code (M12306A8_00000010.TXT, M12306A9_00000010.TXT) - Enhanced early power feature. - Disabling blinking cursor during POST. - Support IPv6 for IMM code. - Modify Setup Menu Help string for Software RAID Configuration - Update Readme files Limitations: Dependencies:
Version 1.01 - BuildID: JQE136AUS ---------------------------------------- Problem(s) Fixed: - System still boots into uefi mode when Legacy Only is the first item of WOL boot order Enhancements: - Support IvyBridge CPU - Support PCIe Gen3 with IvyBridge CPU - Support IPv6 - Support FoD feature - Update VGA Legacy ROM 899-39RI.BIN - Enhance CMOS validating algorithm Limitations: Dependencies:
Version 1.00 - BuildID: JQE128CUS ---------------------------------------- Problem(s) Fixed: Enhancements: - Fix some OEM build issues related to SMBIOS strings. Limitations: Dependencies:
Firmware Version: 10.4.303.14 Supported On: System x Rack
Problems Fixed: - Improved handling of ASU/UCM deployed configurations.
Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products - Lenovo xHMC support for inventory management - Mixed and Concurrent Mode storage (refer to documentation at Emulex.com for more information on this functionality). - 16 total pf's per ASIC in UMC (vNIC2) Mode. Was previously limited to 8 pf's per ASIC.
Known Issues: - UFP mode and concurrent personality are not supported at this time. This will be resolved in the next release (175594, 176654)
- Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack servers.
Problems Fixed: - MAC/PHY loopback test intermittent failures - If BIOS enables "Above 4G decoding", Emulex iSCSI driver is not loaded - Error message appears when saving changes to minimum BW on run time FCoE configuration - Eighth NIC function doesn't come up in UMC mode when configured in PXESelect
Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products
Known Issues: - Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target.(157137)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations(158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Problems Fixed: - Ethtool shows “speed=unknown� sometimes for slave interface. (vNIC & UFP) - SVID values are not present under PXE select utility in vNIC1 mode - UMC Mode/Personality change using IBM ASU tool does not reflect in OCM
Incremental Interoperability: - Grantley based ITE - IBM Flex System CN4052 2-port 10Gb Virtual Fabric Adapter - IBM Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter
Known Issues: - Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target.(157137)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations(158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes. ===============================================================================
Firmware Version: 10.2.377.20 and 10.2.377.23
Supported On: System x and BladeCenter
Problems Fixed: - PXESelect showing incorrect MAC address, bandwidth & SVID values. This bug is a cosmetic issue and only impacts PXESelect. The values which are not displayed correctly in PXESelect can be viewed in UEFI, OCM, and on the switch.(151140) - "Configurations have changed" message seen in UEFI setup screen when no changes were made. This pop-up can be ignored and will be fixed in a future code release.(159086) - FCoE VLAN ID is being displayed incorrectly as hexadecimal in UEFI menu. This is a cosmetic issue only. The correct VLAN is properly assigned, so there is no functional impact. The actual VLAN ID can be observed elsewhere. (159561) - UE seen while booting the system after a CoreDump - When NIC traffic has run on all the 8 vNICs of an ASIC, the vnics of first port are not honoring the assigned BW - SRIOV performance & Fairness for 16VMs is low on Linux and VMware - ML2 VFA5 device name is show "N/A" under IMM web and CLI of server management>Adapters - BW changes not getting updated with vNIC1 mode - Enable 100M/10M speed in set speed for SGMII interface - UCM/vNIC2, Ports/PCI functions supporting FCoE need to be differentiated to make it easier for the user - UCM/vNIC2 ability to program VirtWWN/WWPN independent of BFS Enable - iSCSI boot not working on higher order PCI functions (PF8 11)on 4 port controllers on ARI enabled systems - Can't install Windows2012 onto the iSCSI LUN whose LUN ID is not 0 - Fixed several issues related to IBM Agentless inventory management - Under heavy bi-di traffic with XE102/XE104 network disconnects can occur during failover/switch side link bounce
Known Issues: - Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target.(157137)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations(158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware Version: 10.2.261.41 Supported On: IBM System x
Problems Fixed: - Hit BSOD during VMQ overnight traffic test with cpu affinity change - IBM VFA5 Adapter causing software panic on IBM G8246 Switch in UFP mode - LPVIDs are not getting saved in vNIC2 mode if we change mode from vNIC1 mode to vNIC2 - In MC VINC1, VNIC2, UFP modes, user should see only 4 functions per port for 2 port card
Incremental Interoperability: - Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW for IBM System x - Emulex VFA5 2x10 GbE SFP+ PCIe Adapter for IBM System x - Emulex VFA5 2x10 GbE SFP+ Integrated Adapter for IBM System x
Known Issues: - Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- PXESelect showing incorrect MAC address, bandwidth & SVID values. This bug is a cosmetic issue and only impacts PXESelect. The values which are not displayed correctly in PXESelect can be viewed in UEFI, OCM, and on the switch.(151140)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- "Configurations have changed" message seen in UEFI setup screen when no changes were made. This pop-up can be ignored and will be fixed in a future code release.(159086)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target.(157137)
- FCoE VLAN ID is being displayed incorrectly as hexadecimal in UEFI menu. This is a cosmetic issue only. The correct VLAN is properly assigned, so there is no functional impact. The actual VLAN ID can be observed elsewhere. (159561)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations(158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Notes: 1. An asterisk (*) following a version number represents a certified driver. 2. Arrows (<<) between versions indicate the component has been updated from the previous released software kit. 3. If code is not listed for a particular device, it is not implemented on that device. 4. Three asterisks (***) in the 'Current' column indicates this firmware is actually contained in the respective System UEFI update package, which is separate from this package. Please check that package for version details.
- Fixed issue with tx/rx flow control in shared nic mode where connection to IMM is lost for a period of time after the server is powered off. - Fixed issue with mac address filtering in shared nic mode where connection to IMM is lost after a system reboot.
UEFI and Boot Code: - Added individual port enable/disable functionality in F1 Setup and ASU for the NetXtreme I Quad Port GBE Adapter
Licensed Materials - Property of IBM. (C)IBM and other(s) 2017. IBM is a trademark of IBM in the United States, other countries, or both.
(C) Copyright IBM 2017. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925.