- Fixed SMP passthrough command failure due to smp back off interrupt. Appears in system log as 0x311c0030. (SCGCQ00889925) - Fixed issue where host boot fails in the presence of blank flash/corrupt firmware in flash (SCGCQ00894439) - Fixed issue where SATA drive errors, bad performance, or boot failure may appear after update to 20.00.02.00 firmware (SCGCQ00859226)(Retain Tip# H015210)
Version 1.20.01 - Moderate Impact/Low Probablility of Occurrence ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.03.00 7.27.04.00
- Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
- Fixed issue where acceptable indistro device drivers may not pass minium driver check. BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal. - Fixed issue where update will not install with the 09.101 megaraid_sas device driver.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
- Fixed SMP passthrough command failure due to smp back off interrupt. Appears in system log as 0x311c0030. (SCGCQ00889925) - Fixed issue where host boot fails in the presence of blank flash/corrupt firmware in flash (SCGCQ00894439) - Fixed issue where SATA drive errors, bad performance, or boot failure may appear after update to 20.00.02.00 firmware (SCGCQ00859226)(Retain Tip# H015210)
Version 1.20.01 - Moderate Impact/Low Probablility of Occurrence ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.03.00 7.27.04.00
- Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
Adapters Supported: ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304) ServeRAID M5115 SAS/SATA Controller for IBM Flex System (90Y4390) ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 23.34.0-0018 --------------------
Version 23.34.0-0009 - High Impact/High Probability of Occurrence -------------------- FW Package: 23.24.0-0009
HII: 03.17.14.02
UEFI Driver: 0x06110200
BIOS: 5.50.03.0
MR FW: 3.460.35-6104
iMR FW: 3.460.34-6103
Fixes:
- Fixed the potential of a data miscompare that was observed only at a vendor test facility under very heavy IO and abnormal practices (SCGCQ00995594, Port of SCGCQ00976904)
- Fixed an issue where error "Controller encountered fatal error and was reset" may occur under heavy IO and background operations (SCGCQ00894643)
- Fixed an issue where VMWare may crash when a Guest Operating System is powered off (SCGCQ00872121, Port of SCGCQ00854914)
- Fixed an issue where write-verify performance was lower than expected (SCGCQ00858151, SCGCQ00874193)
- Fixed an issue where "I2C 4 PID 10 SCL STUCK Low! while I2C Rx receiving data intStatus 00008000" may appear in firmware log (SCGCQ01007592)
- Fixed an issue where the Measured Voltage instead of Charging Voltage was displayed in event log (SCGCQ00876489)
- Fixed an issue where Supercap "Battery Not Present" error may occur after shutdown or reboot during a learn cycle (SCGCQ00917115)
- Fixed an issue where Write-through and Write-back cache policies can be changed via Windows Logical Disk Properties. (SCGCQ00856979)
- Fixed an issue where enclosures may go missing when connected in daisy-chain after multiple expander reset cycles (SCGCQ00840725, Port of SCGCQ00818569)
- Fixed an issue where MegaRAID Storage Mananger may display an error message if 'Schedule Consistency Check' is selected. (SCGCQ00852649, Port of SCGCQ00832908)
- Fixed an issue where Patrol Read Properties window does not pop up on MegaRAID Storage Manager (SCGCQ00862478, Port of SCGCQ00797676)
- Fixed an issue where MegaRAID Storage Manager shows messages with Error code 240 and no description (SCGCQ00970948, Port of SCGCQ00904466)
- Fixed an issue where Amber LED may turn on erroneously when an enclosure's slot numbers start with 0 but bay numbers start with 1 (SCGCQ01019622, Port of SCGCQ00903181)
- Fixed an issue where the Generic RAID1 profile option in HII is not greyed-out after creating 64 Virtual Drives (SCGCQ00826822, Port of SCGCQ00816137)
- Fixed an issue where firmware may hang until system is reset (SCGCQ00928869, Port of SCGCQ00923286)
- Fixed an issue where a Virtual Drive may disappear on reboot if it was created with drives from a previously-erased Virtual Drive (SCGCQ00937912, Port of SCGCQ00900237)
- Fixed an issue where Functional Level Reset was not supported (SCGCQ00854343, Port of SCGCQ00840253)
- Fixed an issue where an "L2 unrecoverable cache error" may occur when modifying Patrol read properties (SCGCQ00854668, Port of SCGCQ00847162)
- Fixed an issue where a Hot Spare disk may become Unconfigured Good on reboot (SCGCQ00862477, Port of SCGCQ00803341)
- Fixed an issue where SafeID may change on repeated queries using StorCLI (SCGCQ00949550, Port of SCGCQ00941577)
- Fixed an issue where error "MonTask: line 1272 in file ../../raid/1078dma.c" may occur while running IO in Virtual Machines (SCGCQ01016071, Port of SCGCQ00822403)
- Fixed an issue where incorrect connector information "connector: null x0" shows in MegaRAID Storage Manager (SCGCQ01016040, Port of SCGCQ00996578)
- Fixed an issue where a concurrent Consistency Check cannot be started after resetting adapter to factory defaults (SCGCQ00839437, Port of SCGCQ00838830)
- Fixed an issue where JBOD mode may be disabled if a Virtual Drives is offline (SCGCQ00871662, Port of SCGCQ00827731)
Enhancements:
- Added protection for clearing Foreign Configuration if preserved cache exists (SCGCQ00880783, Port of SCGCQ00842327)
- Enhanced cache restore operation for when restore data size is different than cache size (SCGCQ00860303, Port of SCGCQ00855038)
Version 23.33.0-0044 --------------------
Version 23.33.0-0043 - High Impact/High Probability of Occurrence ----------- Fixes: - Fixed an issue where hard drive slot amber LED not functioning correctly. - Fixed an issue in iMR mode where "Controller encountered fatal error and was reset" errors can occur under heavy IOs and background operations (SCGCQ00894643) (RETAIN Tip H001154) - Fixed an issue where BBU status says optimal but firmware logs indicate that the BBU has failed (SCGCQ00838052) (RETAIN Tip H214857) - Fixed an issue where importing a foreign configuration may fail after reconstruction on 4k sector drives (SCGCQ00830109) - Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350) - Fixed an issue where MR firmware reports "no SMART" error when attaching a PFA drive (SCGCQ00839455) - Fixed an issue where the firmware may hang (enter MonTask) when a guest OS is powered on or off in VMWare (SCGCQ00854914) - Fixed an issue where setting the learn cycle property of iBBU09 gives an I2C error (SCGCQ00831315) - Fixed an issue where "Prepare for Removal" does not work on a PD when drive erase is in progress (SCGCQ00811219) - Fixed an issue where MSM displays "The requested command has invalid arguments" error message if 'Schedule Consistency Check' is selected (SCGCQ00852649) - Fixed an issue where cache memory size in iMR is not showing 0 (SCGCQ00838893) - Fixed an issue where an incorrect MFI_STAT_PD_TYPE_WRONG error is returned by the firmware when PDs with different block size are mixed (SCGCQ00840251) - Fixed an issue where the controller reports cache memory size as 0 when no logical drives are present (SCGCQ00837600) - Fixed an issue where concurrent consistency check cannot be started after issuing "setfactorydefaults" command (SCGCQ00839437) - Fixed an issue where uEFI may report LSI EFI driver "Unhealthy" or "Failed" when more than 64VDs are configured (SCGCQ00831006) - Fixed an issue where functional level reset was not properly showing as unsupported (SCGCQ00854343) - Fixed an issue where the legacy CTRL-H utility may report the wrong PCIe slot number (SCGCQ00799339) - Fixed an issue where the legacy OpROM may show an expander as a JBOD drive in POST (SCGCQ00809682) - Fixed an issue where an encrypted JBOD may be presented to the system in encrypted form even though password was entered incorrectly (SCGCQ00808086)
Enhancements: - Added ability to determine SuperCap revision ID when VPD is not programmed (SCGCQ00828990) - Added support for SES RQST_OK deassertion for customer proprietary JBOD SEP (SCGCQ00834321) - Added feature to enable support for detecting CPLD code version (SCGCQ00840631) - Added feature to enable drive fault LED to be lit when a known-bad drive is connected to the controller (SCGCQ00858142) - Added feature to turn on drive Fault LED when the controller detects a drive that was previously marked Bad (SCGCQ00858140)
Version 23.33.0-0018 - High Impact/High Probability of Occurrence ----------- Fixes: - Incorporated MegaRAID FW stack 5.13 - Fixed an issue where drive temperature cannot be displayed for a drive in Failed or Foreign state (SCGCQ00693959) - Fixed an issue where after creating an LD via StorCLI or MSM the firmware writes into saved power condition mode page (0x1a) of all PDs in the LD and enables their idle timers (SCGCQ00658701) - Fixed an issue where Patrol Read would sporadically correct the same defective LBA repeatedly (SCGCQ00729591) - Fixed an issue where importing a Foreign array onto a new controller may fail with "Cannot force emulate VD to 512E since enable512Esupport is false" error in firmware log (SCGCQ00721106) - Fixed an issue where the controller may enter MegaMon sporadically (SCGCQ00776409) - Fixed an issue where MSM may not report a Full Initialization Aborted error until system rebooted (SCGCQ00759100) - Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350) - Fixed an issue where Link Speed may show UNKNOWN when attaching a 3G or 6G SATA drive (SCGCQ00803522) - Fixed an issue where StorLib may return 0x00ff (fail) code even though operation succeeds when creating a VD out of an existing drive group (SCGCQ00827685) - Fixed an issue where format process of SSD may take much longer than in previous firmware (SCGCQ00674388) - Fixed an issue where controller must have cleared config to enable 240VD unless existing config only included single-drive RAID0 VDs (SCGCQ00559643) - Fixed an issue where some commands would timeout with CDB=ff ff ff ff (SCGCQ00459760) - Fixed an issue where slot ordering in iMR mode might differ from slot numbering in MR mode (SCGCQ00559274) - Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives, preventing data issues (SCGCQ00830977) (RETAIN TIP H214323)
Features/enhancements: - Added support for 512e drives (SCGCQ00425363) Enhanced Event Log to include CVPM health details after every Learn Cycle to allow closer monitoring of CVPM health (SCGCQ00819877) - Implemented a retry for reads of CVPM data to avoid erroneous event 386 or 150 in the Event Log (SCGCQ00392439) - Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490819) - Implemented ability for firmware to read drive temperature immediately following SAS discovery (SCGCQ00602573) - Added ability to clear the MaintainPdFailHistory (SCGCQ00474559)
Version 23.29.0-0015 - Critical ------------------- Enhancement - Provide mechanism to disable PCIe backchannel training via SBR. Fixes: - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where foreign configuration import could fail. - Fixed an issue where storcli.exe /c0 show all command repeatedly prints to termlog with respect to upgradekey presence. - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the order of the first 64 VDs in the POST is not the same sequence as returned from the firmware. - Fixed storCLI adpfwflash option crash and adpallinfo option failure. - Reduced the bootblock Init time, which effectively reduces the configuration retry time to approximately 700 mS.
Version 23.22.0-0024 - Non-Critical ------------------- Enhancement(s): - Display the Native Command Queuing (NCQ) enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI. - Added support for ServeRAID M5100 Series 2GB Flash/RAID 5. Fix(es): - Disable PI CRC checking when the drive is not initialized during a CC. - Increased the SuperCap learn time out value for 2GB TMM-B solution. - Fixed an issue for 2GB memory modules where SuperCap does not get connected to the controller and hence cache offload fails. - Fixed an issue where cache policy of virtual drives(VD) does not change to write through(WT) mode even after detecting a bad supercap. - Fixed an issue where a RAID configuration created with physical disks in powersave mode could be lost after rebooting the system. - Fixed an issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed an issue where the system is not allocating memory correctly when MR and iMR controllers are in the same system. - Fixed an issue where deep learn does not start immediately when the relative state of charge (RSOC) is just equal to 95%. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled.
Version 23.16.0-0027 - Critical ------------------- Fix(es): - Addressed data exposure issue when using CacheCade - Fixed issue where Supercap shows 0 Capacitance - Fixed iBBU09 battery issue that caused a VD cache policy to remain in write-through mode after a manual relearn - Fixed iBBU09 battery issue that caused a VD cache policy to periodically toggle between write-back/write-through mode - The limits for iBBU09 battery charging were not updating properly in a learn cycle - Ensures a single supercap pack is not supported on 2GB memory module. - Resolves a firmware crash seen while doing continuous sas cable pulls. - Ensures OpROM loads even if segment address is 0xC0000. - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.16.0-0018 - Suggested ------------------- Fix(es): - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.12.0-0016 - Suggested ------------------- Fix(es): - Added isync to prevent speculative execution while memory is being allocated. - Delayed enablement of POM until AFTER valid memory range is provided by host system.
Version 23.12.0-0011 - Suggested ------------------- Enhancement(s): - Support for 512e and 4k SAS/SATA hard drives added - Implemented Limited Band Charging for iBBU09 (RETAIN tip H21631) - Changed BIOS check to determine if running in HAMR, in order to ensure nothing gets broken when user has an iButton which is not programmed. - Changed controller status for safe mode to show controller status as safe mode and disable debug message logging in serial port.
Fix(es): - Addressed an issue where deeply discharged Cache Vault Power Modules would be prematurely be marked as failed. - Fixed an issue where HII hangs when trying to enter configuration management while in safe mode. Changed the safe mode warning message as below: "Controller is running in safe mode. Safe mode is used for diagnostic purposes only. Limited operations such as Configuration Preview, Clear Configuration and View/Change Controller Properties are allowed in this mode. Other operations such as Create Configuration, Import and Clear Foreign Configurations are not allowed. To exit safe mode, correct the fault, and reboot your computer." - Fixed an issue where having more than three adapters results in a calculation error for the offset to store physical disk info for fourth adapter, due to BIOS not clearing upper byte of AX (that is AH which is containing some non zero value). - Fixed an issue where the Wrong spanned drive group size is displayed by WebBIOS (Ctrl-H).
Version 23.7.1-0010 - Suggested ------------------- Fixes: - Fix an issue related to the where the TSOC (EEPROM) is not able to read or write from the firmware which will result in the message "Incompatible secondary iButton present." - Fix a HII broswer issue where Cachecade virtual drive can be selected as a boot device. - Fix a HII broswer issue where the user is unable to clear the controller configuration when there are no drives attached. - Fix an issue where the BIOS doesn't display the RAID level and VD size correctly at BIOS POST.
Version 23.7.1-0009 - Suggested ------------------- Fixes: - Fixed an issue where SoH is bad after a learn cycle but iBBUI shows good status. - Fixed an issue where hi-temp warning was not being displayed.
Version 23.7.0-0037 - Suggested ------------------- Fixes: - Corrected differential signals for Phys 2 and 3 that caused slot numbers in simple swap configurations to be incorrect. - Fixed an issue when 'maintain PD failed history' is enabled, and a cable is removed while a drive is added, the drives state goes to optimal instead of foreign unconfigured bad. - Fixed a problem where a capacity change is reported after a rebuild completes on a Cache Cade volume. - Fixed a controller firmware hang when the recovery of a medium error takes to long. - Fixed an issue where the SATA BBM (Bad Block Manager) list was being corrupted. - Fixed an issue where FoD (Feature on Demand) Options were being lost because of errors while accessing the TSOC. - Fixed a problem where the controller firmware would crash and drives would go offline when a bad block entry was created during a check consistency operation. - Fixed a problem where drives were being marked unconfigured bad (foreign) on reboot. - Fixed problem where a member of a CacheCade volume did not get marked as foreign when the drive was pulled with 'maintain PD failed history' enabled. - Fixed a problem where during a rebuild, a former hot spare that was now in a state of unconfigured good, moved back to the state hot spare, which then automatically started a copyback operation, causing the rebuild to restart. - Fixed a problem where a controller fault occurred during a reboot while a physical device was in progress of a PD Erase.
Version 23.7.0-0029 - Suggested ------------------- Enhancements: - Added support for Cache Cade 2.1 - Added Support for PI Drives
Fixes: - Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup. - Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive - Added a check for the presence of PD before writing the data arms of a protected LD during BGI. - Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS. - Fixed an issue with USB Cacheoffload restore fails after multiple power cycles onServeRAID M51xx controllers. - Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data. - Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash. - Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds. - Fixed background initialization watermark conversion to PD LBA. - Fixed write protected R1E data arms during initialization. - Fixed an issue where MR firmware crashed while discarding pinned cache. - Fixed an issue where a dirty LD dependency information of SSD pd has stale entries. - Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd - Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset. - Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe. - Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM. - Fixed an issue where the firmware was wrongly adding puncture entries. - Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table. - Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event. - Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events. - Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled. - Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value. - Fixed an issue in which a Patrol Read may not start under certain conditions. - Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved. - Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero. - Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU. - Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed. - Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running. - Fixed an issue where CC stops progressing on a R6 VD with media errors. - Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test). - Fixed an issue where controller features are lost if RAID Key was not detected. - Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering. - Fixed an issue where "Native configuration is no longer supported" message in post. - Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low. - Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Version 23.2.1-0043 - Suggested ------------------- Fixes: - Fixed an issue where "Potential non-optimal configuration due to drive PD commissioned as emergency spare" alarm would trigger erroneously. - Fixed an issue where Copyback does not progress upon inserting drives. - Fixed an issue When allowMixInLD is Disabled, and causes Copyback Fails after Rebuild to Emergency Hot Spare. - Fixed an issue where the Firmware faults while flashing. - Fixed an issure where querying SMART / PFA Status to Return all zeros in Sense Data. - Fixed an issue where the Re-inserted Drives becomes Unconfigured_good causing auto rebuilds to fail to start.
Version 23.2.1-0033 ------------------- - Initial release ibm_fw_sraidmr_6gb-23_34_0-0018_linux_32-64_chg
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.23.00 Build ID: IBM12300 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.23.00 - Update Utility release for IBM x86 servers.
Note 1: *- Add Lenovo Branded Part Number in supporting list
Note 2: *- Remove the legacy HDD/SSD in this Update program, the drives were out of production by 4Q2014 or no firmware changes since 1Q2014. There is a seperate update program to support these drives.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to LC5H - See Note 1* above
- ST2000NM0043, ST4000NM0043 to FC5D - See Note 1* above
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to FC6D - See Note 1 * above
- ST3300657SS, ST3600057SS to LA5A - See Note 1* above
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to K3LC - See Note 1 * above
- HUS724020ALS61, HUS724040ALS61 to P3LC - See Note 1* above
- WD1001FYYG-23S, WD2001FYYG-23S to XA39 - See Note 1 * above
- WD5003ABYX-23 to WC42 - See Note 1 * above
- ST1000NM0045, ST2000NM0045, ST4000NM0025 to LK84 - See Note 1* above
- ST6000NM0095 to LC84 - See Note 1* above
- MG04SCA60EE to TG45 - See Note 1* above
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6F
SAS 2.5"
- ST300MM0006, ST600MM0006, ST900MM0006 to L56R - See Note 1* above
- ST300MM0026, ST600MM0026, ST900MM0026 to F56F - See Note 1* above
- ST1200MM0007 to L57D - See Note 1* above
- ST1200MM0017 to F578 - See Note 1* above
- ST300MP0005, ST600MP0005 to L67J - See Note 1* above
- ST300MP0015 to F674 - See Note 1 * above
- ST9146853SS, ST9300653SS to L63M - See Note 1* above
- ST9500620SS, ST91000640SS to LD2L - See Note 1* above
- HUC156030CSS20, HUC156060CSS20 to K2GF - See Note 1* above
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to K2EK - See Note 1* above
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to P2EK - See Note 1* above
- AL13SEB300, AL13SEB600, AL13SEB900 to TB37 - See Note 1* above
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to K4CC - See Note 1* above
- HUSMM1640ASS20E, HUSMM1680ASS20E to P4CC - See Note 1* above
- ST1000NX0453 to LD48 - See Note 1* above
- HUC101860CSS20, HUC101890CSS20, HUC101812CSS20, HUC101830CSS20 to K2H9 - See Note 1* above
- HUC101860CSS20E, HUC101890CSS20E, HUC101812CSS20E, HUC101830CSS20E to P2H5 - See Note 1* above
- HUC101818CS420 to J5H9 - See Note 1* above
- HUC101818CS420E to N5H9 - See Note 1 * above
- ST1800MM0018 to L59B - See Note 1* above
- ST1800MM0068 to F594 - See Note 1* above
- AL14SEB180E to TL43 - See Note 1 * above
- USMR1625ASS20E to P4C9 - See Note 1* above
SATA 3.5"
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to LB5F - See Note 1* above
- WD1004FBYZ-23YC, WD2004FBYZ-23YC to WH03 - See Note 1 * above
- ST1000NM0055, ST2000NM0055, ST4000NM0035 to LJ84 - See Note 1* above
- ST6000NM0115 to LB83 - See Note 1* above
- MG04ACA600E to TJ42 - See Note 1* above
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to LE2B - See Note 1* above
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MC50 - See Note 1* above
- SSDSC2BB800G4I to D201NE40 - See Note 1* above
- ST1000NX0423 to LE45 - See Note 1* above
SATA 1.8"
- MTFDDAA480MBB, MTFDDAA800MBB to MC50 - See Note 1* above
Below drives are removed from the program - See Note 2* above
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.21.00 Build ID: IBM12100 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.21.00 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5K
- ST2000NM0043, ST4000NM0043 to EC5H
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6E
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC6E
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to MPXSJ3LA
- HUS724020ALS61, HUS724040ALS61 to MPXSN3LA
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to VCXSA810
SAS 2.5"
- HUC156030CSS20, HUC156060CSS20 to KFXSJ2G8
- HUC101212CSS60 to CPXSJ2MC
- HUC101212CSS61 to CPXSN2MC
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to CEXSJ2EL
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to CEXSN2EL
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to SPXSJ4CC
- HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to SPXSN4CC
SATA 3.5"
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD40
- ST2000NM0024, ST4000NM0024, ST6000NM0024, ST5000NM0024 to BB67
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5G
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB47
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA35
- STECM8PSB2 to 2864/SM08
SATA 1.8"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB47
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.20.00 Build ID: IBM12000 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.20.00 - Update Utility release for IBM x86 servers.
Note: *- Update the firmware on SAS/SATA SSDs to fix PSIRT issue with Intel SSD's.
This package acknowledges support and may include updates for drives with product ID strings of:
SATA 2.5"
- SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB480G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA39.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC34.
SATA 1.8"
- SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to D201NE40.
- SSDSC1NA200G3I, SSDSC1NA400G3I to 5DV1NA39.
- SSDSC1NB800G4I to D201NE40.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.19.06 Build ID: IBM11906 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.19.06 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
- Remove TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I from FW update utility for new code updating break Raid.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.18.03 Build ID: IBM11803
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.18.03 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read.
RETAIN TIP: H214635 MIGR-5098037
SAS 3.5"
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6B - similar to Note * above.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5J - Enhance Dither Algorithm to prevent dwelling during Idle environments. - ST2000NM0043, ST4000NM0043 to EC5E - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SAS 2.5"
- TXA2E21600GA6I to GB7P - add support in profile.
- HUC156030CSS20, HUC156060CSS20 to J2G6 - add support in profile.
SATA 3.5"
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB66 - similar to Note * above.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5F - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SATA 2.5"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB42 - add support in profile.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I to D201NB39 - add support in profile.
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read. RETAIN TIP: H214635 MIGR-5098037
This package acknowledges support of qualified devices and may include updates for drives with product ID strings of:
SAS 3.5"
- HUS724020ALS61, HUS724040ALS61 to N3L6 - internal updates.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5H - See Note * above.
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC66 - see Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- Other drive codes are present for support identification.
SAS 2.5"
- WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA34 - follow-on release. - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC33 - follow-on release.
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EH - follow-on release.
- TXA2D20200GA6I, STXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I to GB7P - enhancements.
- ST300MM0006, ST600MM0006, ST900MM0006 to B56T - See Note * above.
- ST300MM0026, ST600MM0026, ST900MM0026 to E56E - See Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- ST1200MM0007 to B57E - See Note * above.
- ST1200MM0017 to E577 - See Note * above.
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to J4C8 - See Note # above - HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to N4C8 - See Note # above
- Other drive codes are present for support identification.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1D - performance inhancements.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5C - See Note * above.
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB65 - See Note * above.
- WD2003FYYS-23W0B0 to WA36 - configuration additions.
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD39 - configuration additions.
- HUA723030ALA6 to MKAOA930 - enhancements. - HUA723020ALA6 to MK7OA930 - enhancements.
- Other drive codes are present for support identification.
SATA 2.5"
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA34 - ship level.
- Other drive codes are present for support identification.
SATA 1.8"
- Drive codes are present for support identification.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.05 Build ID: IBM11605
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.05 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4B - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L6 - Fixed unexpected 02/04/11 error; Fixed a drive logic self-initiated reset on read/write long commands; Fixed a problem with large write sequential transfers.
SAS 2.5"
- ESXSST9500620SS, ESXSST91000640SS to BD2K - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
SATA 2.5"
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.04 Build ID: IBM11604
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.04 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB42 - > A drop in host power supply may cause bad block growth > The bad block table may not properly increment > Background activity may continue after STANDBY, STANDBY IMMEDIATE, or SLEEP > ID173/202 may show incorrect value when the NAND erase count exceeds 3000 > Changed DRAM timing > Event log may be programmed when supply voltage from host is out of specification
- SSDSC2BB012I4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix that corrects a condition that may cause the drive to not respond.
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND34 - will require two update runs and system reboots for device fw update to complete--Please See the limitations in readme for details.
> Performance improvement on sub-4KB sequential write > Fix drive reports higher than actual data units read and write > Fix drive incorrectly counts unsafe power shutdown events on warm reboots
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.03 Build ID: SAS11603
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.03 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST2000NM0034, ESXSST4000NM0034, ESXSST6000NM0034 to BC67 - GA code. - ESXSST2000NM0054, ESXSST4000NM0054, ESXSST6000NM0054 to EC66 - GA code.
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA39 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SAS 2.5"
- ESXSTXA2D20200GA6, ESXSTXA2D20400GA6, ESXSTXA2D20800GA6, ESXSTXA2E21600GA6 to GB7P - fixes implemented to support PI issues.
- ESXSST300MP0005 to B675 - GA code. - ESXSST300MP0025 to E671 - GA code.
- ESXSST300MP0035, ESXSST600MP0035 to B683 - GA code. - ESXSST300MP0045, ESXSST300MP0045 to E685 - GA code.
- ESXSST300MX0012, ESXSST600MX0052 to BH53 - GA code.
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23DS to ZA34 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; drive was reporting 0B/11 instead of 03/11. - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC33 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1C - GA code
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE2B - Update configuration change.
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB34 - > Some Out of Range LBAs accepted by NCQ commands where they should be aborted. > SataDownShift.srt failed, Smart attribute Raw lost with perform dirty pwr cycle . > Low Power Entry Bug Identified from Marvell Code Review > Track Timeout, Marvel 373 sequencer issue > Unreasonable ECC count in SMART ID 195
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program for Linux. Version 1.16.00 Build ID: SAS11600
******************************************* IBM SAS/SATA HDD/SSD Update Program Version 1.16.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37 - Resolves drive initiated reset (DBS (Debug Stop event)) encountered under a narrow timing window (~1ns) for specific command/access patterns, due to the drive’s handling of command automation where it was possible for an internal hardware resource conflict to occur between two tasks.
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NSto BE2A
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA37
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND32 - will require a system reboot for device fw update to complete.
********************************************************************* SAS/SATA HDD/SSD Update Program Version 1.15.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37
- ST9500620NS, ST91000640NS to BE2A
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9500620NS, ST91000640NS
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA36
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
NOTE TO SERVICE - Reference RETAIN TIP H29851 ******************************************* SAS Hard Disk Drive Update Program Version 1.14.04 Critical Release Reference RETAIN TIP H29851
This package includes updates to drives with product ID strings of:
SAS 2.5"
Initial code Release - SMK3001GRDB, SMK6001GRDB, SMK9001GRDB to SB35
SATA 2.5"
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA36 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB37 - fix to prevent possible drive lock up during format.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA36 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB37 - fix to prevent possible drive lock up during format.
=================================================================== IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to E568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX
ibm_fw_hddlenovo_sas-1_23_00_linux_32-64_chg
ServeRAID M and MR10 Series SAS Controller Driver for Linux (also supports MegaRAID 8480 SAS Controller)
Adapters Supported: - ServeRAID M1215 SAS/SATA Controller for IBM System x (46C9114) - ServeRAID M5210e SAS/SATA Controller for IBM System x - ServeRAID M5210 SAS/SATA Controller - ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) - ServeRAID M5110e SAS/SATA Controller for IBM System x - IBM Flex System Storage Expansion Node - ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) - ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304) - ServeRAID M5115 SAS/SATA Controller for IBM System x (90Y4390) - ServeRAID M5015 SAS/SATA controller (46M0829) - ServeRAID M5014 SAS/SATA controller (46M0916) - ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) - ServeRAID M1015 SAS/SATA Controller (46M0831) - IBM ServeRAID MR10il SAS controller (44E8767) - IBM ServeRAID MR10is SAS controller (44E8695) - IBM ServeRAID MR10ie (CIOv) SAS controller (46C7167) - IBM ServeRAID MR10i SAS controller (43W4296) - IBM ServeRAID MR10k SAS controller (43W4280) - IBM ServeRAID MR10M SAS controller (43W4339) - MegaRAID 8480 SAS controller (39R8850)
Version 6.810.09.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes:
- Fixed an issue where deadlock may occur when the Automatic Event Notification thread runs in parallel with error handler thread (SCGCQ00911332, Port of SCGCQ00868731)
- Fixed an issue where driver will operated in RDPQ mode regardless of whether firmware has advertised support or not (SCGCQ00872542)
- Fixed an issue where system may reset with error "BUG: unable to handle kernel NULL pointer dereference at 00000000000000d0" preceded by error "megasas: target reset FAILED!!" (SCGCQ00875223)
- Fixed an issue where driver MFI frames could be freed twice (SCGCQ00879190)
- Fixed an issue where some out-of-band commands had different timeouts than others (SCGCQ00884247)
- Fixed an issue where performance was lower on async IO submissions from the SCSI mid layer (SCGCQ00884242)
- Fixed an issue where a kernel panic may occur if the system is reset or fail to reboot (SCGCQ00859634, Port of SCGCQ00857740)
- Fixed an issue where Task Management frames were not being dumped after the Tast Management Reply frame data (SCGCQ00860038)
- Fixed an issue where a fatal error may occur when an out-of-band command times out during an Online Controller Reset (SCGCQ00882011, Port of SCGCQ00868661)
- Fixed an issue where kernel may hang when many commands are timing out or many Automatic Event Notifications are being processed (SCGCQ00857245)
- Fixed an issue where megaraid_sas module was not being included inside initrd/initramfs (SCGCQ00880965)
- Fixed an issue where kernel may panic if driver does not setup IRQs for non-MSI-x interrupt mode (SCGCQ00870263, Port of SCGCQ00867873)
- Fixed an issue where driver return code is based on command completion rather than command return code (SCGCQ00856103, Port of SCGCQ00856089)
- Fixed an issue where Tape drives may not be detected by the Operating System (SCGCQ00914385, Port of SCGCQ00911702)
- Fixed an issue where max_sectors per IO request may be set to more than firmware can handle (SCGCQ00917992, Port of SCGCQ00917399)
- Fixed an issue where an IERR may occurr on heavy IO with Failover (SCGCQ00864111, Port of SCGCQ00736612)
Enhancements:
- Enhanced queue depths in driver for physical disks based on interface type (SCGCQ00879700)
- Improved naming of internal functions (SCGCQ00866064)
- Enhanced reply queue to support queue depth greater than 1K (SCGCQ00853521)
- Added feature for driver to support Task Management for JBOD and Virtual Drives (SCGCQ00854635)
- Added module parameter to disable 1M IO support and set default to enable 1M IO support (SCGCQ00911362)
- Enhanced tasklet initialization so it would occur before setting up IRQs (SCGCQ00914393, Port of SCGCQ00911709)
- Simplified HB handling for SR-IOV (SCGCQ00864113, Port of SCGCQ00700580)
- Enhanced driver to update Online Controller Reset capability when it changes (SCGCQ00914389, Port of SCGCQ00908352)
- Added feature to print Critical, Fatal and Dead firmware events into system logs (SCGCQ00868723, SCGCQ00882010, Port of SCGCQ00866176)
- Enhanced HB handling to align with behavior on other Operating Systems (SCGCQ00864117, Port of SCGCQ00707323)
- Removed excess dead code (SCGCQ00850012)
Version 6.808.16.00 - -------------------
Version 6.808.14.00 - Initial release -------------------
ibm_dd_sraidmr_6_810_09_00-1_sles12_32-64_chg
uEFI Flash Update Version 2.30 (BuildID D7E156D) Change History
Version 2.30 - BuildID: D7E156D ------------------------------------------------- Problem(s) Fixed: - The string showed wrong position when buiding RAID after the refresh mechanism added in new adapter firmware. Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.21 - BuildID: D7E154B ------------------------------------------------- Problem(s) Fixed: - Updated Intel UEFI x64 PCI-E gigabit driver . v7.0.06 - Updated PXE Option ROM: v1.5.78 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.11 - BuildID: D7E152C ------------------------------------------------- Problem(s) Fixed: - x3550M4/x3650M4 with E5-2690V2 has warning event generated when ambient temperature at 27/30 degrees Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.02 - BuildID: D7E150C ------------------------------------------------- Problem(s) Fixed: - Fixed Abnormal option place for Emulex 4Gb FC in UEFI - Fixed OpenSSL vulnerabilities as reported in CVE Advisories: CVE-2015-1793, CVE-2015-1789, CVE-2015-1790, CVE-2015-1792
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.91 - BuildID: D7E148B ------------------------------------------------- Problem(s) Fixed: - Updated UEFI to address these vulnerabilities: CVE-2015-0209, CVE-2015-0286, CVE-2015-0287, CVE-2015-0288, CVE-2015-0289 - imm clock drift after ac cycle on dongshan
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.82 - BuildID: D7E146C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Turn off High Precision Event Timer (HPET) from uEFI setting. - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.71 - BuildID: D7E142A ------------------------------------------------- Problem(s) Fixed: - Fixed an issue with continuous reboots when applied new LSI FW and the Remote Console setting is Enabled. Enhancements: Limitations: Dependencies:
Version 1.70 - BuildID: D7E140Z ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58N Version: 4.30 (ibm_fw_imm2_1aoo58n-4.30_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: D7E136W ------------------------------------------------- Problem(s) Fixed: 1. Can not boot up from IMM Remote Mount with USB key. 2. Fixed that LR-DIMM 1333Mhz 1.35V memory speed is incorrect at Balanced mode Enhancements: 1. Support two DIMM Per Channel run at 1866Mhz for 16GB RDIMM 1.5V DR x4 & 32GB LRDIMM QR x4 2. Variable store self-healing. Limitations: 1. When flashing UEFI from version 1.30 or later down to version 1.20 or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30. Dependencies: 1. The IMM firmware must be at BUILDID: 1AOO50D Version: 3.65 (ibm_fw_imm2_1aoo50d-3.65_anyos_noarch) or higher prior to installing UEFI version 1.60. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.50 - BuildID: D7E134E ------------------------------------------------- Problem(s) Fixed: 1. Corrected IPv6 reboot problems 2. Corrected 64bit resouce allocation problems 3. Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot Enhancements: 1. Add support for Intel Xeon processor E5-2600 v2 product family 2. Add notification when UEFI detects GPT corruption during POST 3. Add support to configure the "Next Boot to F1 setup" function out of band 4. Add long text support in F1 setup help string 5. Implement LAN Fail-Over function Limitations: Dependencies:
Version 1.40 - BuildID: D7E128D ------------------------------------------------- Problem(s) Fixed: 1. Fixed that IB mezz card still shows "Standby Power Enable/Disable item" in uEFI setup menu 2. Fixed that can not enter F1 setup menu after 3x POST failure occurred. 3. Correct the PCIE link control of Active-State Power Management(ASPM) setting to result the PCI/NMI problem 4. Fix that UA-101 audio device hang at legacy mode Enhancements: 1. Multiple PCIe adapter BARs 2. Configurable MMIO base 3. Support Firmware first feature 4. Add informational messages when existing UEFI F1 setup menu 5. Add OEM SPD feature 6. Fixed the Preboot Execution Environment(PXE) function with Emulex 10 GbE Virtual Fabric Adapter III Limitations: Dependencies:
Version 1.30 - BuildID: D7E124C ------------------------------------------------- Problem(s) Fixed: 1. Fixed that some USB device hang at legacy mode (UA-101 USB audio device) 2. Disable CPU C-state and phase shedding for Volterra EOS issue Enhancements:
Limitations: Dependencies:
Version 1.30 - BuildID: D7E124A ------------------------------------------------- Problem(s) Fixed: 1. UEFI option 43 failed to work 2. ITP can't trigger CPU2 IERR 3. MBE WHEA-log can't match ECC Uncorrectable event 4. iMM lost connection with shared NIC on Intel mezz card (Meteorite) after power cycle Enhancements: 1. Change UDIMM 2DPC@1333Mhz 1.35V algorithm to meet performance specification requirement 2. Support ROM Recovery feature (Auto Promotion under Backup Bank Management Method) Limitations: Dependencies:
Version 1.20 - BuildID: D7E120C ------------------------------------------------- Problem(s) Fixed: 1. Sevaral uEFI OS boot failed with F12 boot menu HDD0. 2. Console Switch 1754A2X with KB & Mouse are not responding in EFI Web BIOS 3. Multiple issues caused by USB over current, including: 3.1 Unable to use front USB Port to flash firmware, load operating system or install a keyboard/mouse. 3.2 VMWare Purple Screen of Death (PSOD) during OS installation or booting. 3.3 Intermittent USB configuration change under Windows. 4. Fan speed goes to 100% after enable several TPM settings. 5. TPM 1.2 UEFI Preboot Interface Test (found CPU error) Enhancements: 1. Enable DRAM phase shedding 2. Support FastSetup feature 3. Support UDIMM 2DPC@1333Mhz running at 1.35V Limitations: Dependencies:
Version 1.10 - BuildID: D7E116A ------------------------------------------------- Problem(s) Fixed: 1. E5-2690 cannot run frequency at 2.9GHz(only 2.8GHz) when turn off Turbo mode. 2. Instruction for TPM enablement has type error. 3. CPU can not enter deep C status with uEFI 11I under RHEL5.7 64 4. Failed to boot from CDDVD ROM with uEFI OS 5. Best Card cannot link with Gen3 on Mezz Card slot 6. BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event and PCI error LED was off 7. iSCSI ISID mismatch under uEFI BIOS Settings. 8. TCG TPM Integration Test (Manual) random failed under WIN2K8 R2 SP1 with uEFI_11L 9. QPI link speed and Turbo mode show incorrect with M1 stepping CPU. 10.The format of System Event Log is uncorrected 11.Legacy Thunk Support is malfunctional 12.DIMM slot 13-24 can NOT indicate which memory was falut when trigger MBE on Mirror mode by bugged DIMM 13.ASUT74H can't find any iscsi item 14.BestCard ASB_Wiz stress test is failed with Gen 3 link speed 15.Fail to set some of PXE items with ASU76h 16.Can not boot into WinPE in RAID HDD on Crossfield 17.Personality can not be switched in OCM tool no matter FOD is imported 18.Processor speed is incorrect when system is idle 19.VLAN ID can be configured to ID 0 20.PCIX Best Card cannot get software NMI when trigger some of PCIX command 21.10G PCIe slot got incorrect slot error event by PCI-E Best Card 22.PCIe BestCard expr_flow got IERR 23.PCI led on and uEFI report OUT_OF_RESOURCES when system plug-in BussardE 10GbE adapter. 24.Processor speed is incorrect when system is idle w/ E5-2637 M1 25.Console redirection can not work normally with com2com. 26.No screen output with SOL connection 27.iSCSI Attempt will disapper when system reboot several times. 28.BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event on Internal RAID Slot 29.Purple Screen of Death when boot/install ESXi 5.0 to Hypervisor key
Enhancements: 1. Open Optimized Boot setup item with default enable 2. Open Legacy Thunk support setup item 3. Change Operating Mode from Custom Mode to Efficiency - Favor Performance 4. Remove USB port0 OverCurrent Mapping 5. Add DriverCodeDisplay error code on screen function
Limitations: Dependencies:
Version 1.00 - BuildID: D7E112J (Initial Release) ------------------------------------------------- Problem(s) Fixed: 1. High failure rate on front USB cable position/design cause all USB device disappear and could not flash via UXSPI
Enhancements: Limitations: Dependencies:
ibm_fw_uefi_d7e156d-2_30_anyos_32-64_chg
Firmware Update for IBM High IOPS Modular Adapter
Controller Supported: - IBM 300 GB High IOPS MLC Modular Adapter (90Y4361) - IBM 600 GB High IOPS MLC Modular Adapter (90Y4365) - IBM 800 GB High IOPS MLC Modular Adapter (90Y4369) - IBM 300 GB High IOPS SLC Modular Adapter (90Y4373)
Version 7.30.05.00-1 - Non Critical -------------------- - Added Support in RHEL 5.9 indistro device driver
Version 7.30.05.00 - Initial release ------------- ibm_fw_mpt2sas_hiop-7_30_05_00-1_linux_x86-64_chg
uEFI Flash Update Version 2.34 (BuildID VVE152E) Change History
Version 2.34 - BuildID: VVE152E ------------------------------------------------- Problem(s) Fixed: - Fixed a potential Setup Screen format problem when configuring a RAID adapter - QUAL NIC Intel Onboard OPRom update from Intel 20.7 ISO package Enhancements: Limitations: Dependencies:
Version 2.22 - BuildID: VVE150C ------------------------------------------------- Problem(s) Fixed: - Fixed the issue of generating an incorrect ambient temperature warning event while operating within processor specification. Enhancements: - Update copyright to 2016 on splash screen Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOE58T Version: 4.31 (oem_fw_imm2_1aoe58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.92. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.11 - BuildID: VVE148B ------------------------------------------------- Problem(s) Fixed: - Fixed OpenSSL vulnerabilities as reported in CVE Advisories: CVE-2015-1793, CVE-2015-1789, CVE-2015-1790, CVE-2015-1792 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOE58T Version: 4.31 (oem_fw_imm2_1aoe58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.92. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.00 - BuildID: VVE146A ------------------------------------------------- Problem(s) Fixed: - Updated UEFI to address these vulnerabilities: CVE-2015-0209, CVE-2015-0286, CVE-2015-0287, CVE-2015-0288, CVE-2015-0289 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.92. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.92 - BuildID: VVE144C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428 - Addressed a problem where the PCI Generation setting was missing in the UEFI setup menus for Mezz adapters. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.92. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.80 - BuildID: VVE142E ------------------------------------------------- Problem(s) Fixed: - Corrected an issue which might cause system get an NMI event with PCIe device installed on PCIe slot 5. Enhancements: Limitations: Dependencies:
Version 1.73 - BuildID: VVE142D ------------------------------------------------- Problem(s) Fixed: - Fixed an issue with continuous reboots when applied new LSI FW and the Remote Console setting is Enabled. Enhancements: Limitations: Dependencies:
Version 1.71 - BuildID: VVE142B ------------------------------------------------- Problem(s) Fixed: Enhancements: - Supported IBM eXFlash DDR3 Storage DIMM firmware version 1.4.7. Limitations: Dependencies:
Version 1.70 - BuildID: VVE142A ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm - Supported IBM eXFlash DDR3 Storage DIMM Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58N Version: 4.30 (ibm_fw_imm2_1aoo58n-4.30_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: VVE136A ------------------------------------------------- Problem(s) Fixed: - Fix Can not boot up from IMM Remote Mount with USB key. - Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot - Fix that LR-DIMM 1333Mhz 1.35V memory speed is incorrect at Balanced mode
Enhancements: - Prevent the system unexpected shutdown with HCDIMM - Variable store self-healing
Limitations: Dependencies:
Version 1.51 - BuildID: VVE134T ------------------------------------------------- Problem(s) Fixed: - System doesn't boot to HII after Pressing 'C' with missing configuration.
Enhancements: - IVB Support. - Prevent the system unexpected power off with sensor planar voltage fault
Limitations: Dependencies:
Version 1.50 - BuildID: VVE134S ------------------------------------------------- Problem(s) Fixed: - Reboot to UEFI setup using ASU or Windows 2012 - Enable help string scroll when the help text cannot show all at current page. - Add notification and recovery option when UEFI detects GPT corruption during POST - Implement LAN Fail-Over function Enhancements: - IVB Support. Limitations: Dependencies:
Version 1.40 - BuildID: VVE128B ------------------------------------------------- Problem(s) Fixed: - IB Card show "Standby Power Enable/Disbale item" in uEFI setup menu - Can Not enter F1 setup menu after POST failure occur. - Correct the PCIE link control of Active-state power Management(ASPM) setting to result the PCI/NMI problem
Enhancements: - Multiple PCIe adapter BARs - Configurable MMIO base - Support Firmware first feature - Add informational messages when existing UEFI F1 setup menu - Add OEM SPD feature Limitations: Dependencies:
Version 1.30 - BuildID: VVE124A ------------------------------------------------- Problem(s) Fixed: - iSCSI Out of Band Configuration Fails. - Failed to change the value of some memory settings with ASU(ASUT78C). - MBE WHEA-log can't match ECC Uncorrectable event. - System administrator password is set but system still can get fully access right in F1 uEFI without asking password if press and then press . - Update uEFI README file. - IMM lost connection with shared NIC on Intel mezz card. - Onboard NIC 4 doesn't work when boot Linux OS with paramet. - System hang after memory multibit error occurred and then system reboot. - System could be hang if Intel Network adapter is installed (Dallas). - TPM setting would not be applied in ESC+SAVE issue . - The Pre-Boot value cannot set MUX switch to BMC by uEFI SETUP menu. - Kingston manufactory ID will shown as "Unknown" in SMBIOS type 17. - Fixed TCG TPM Integration manual test failed in Windows 2012. - System hang at IBM LOGO with Broadcom Dual Runner card. - Cause [W.3938002]Boot Config Error. - Disable CPU C-State and Phase Shedding to prevent Voltage Regulator EOS issue. - UEFI setting on F1 menu doesn't sync with ASU setting when boot mode=legacy only.
Enhancements: - SMBIOS type17s support 2133 data rate for dimm maximum speed. - Remove some unuseful code due to IMM changed flow when uefi primary bank integrity check failure. - Enabled DCA item in processors menu of uEFI SETUP. - Improve clock timing for Netlist 16GB HCDIMM. - Add a workaround to patch an yellow mark(AHCI) shown on Windows 2012. - Improve FoD (Feature On Demand) by Transition Table update . - Improve thermal limitation in SSD adapter (LSI High IOP, QLogic ). - Improve behavior of PCI-X error handling.
Limitations: Dependencies:
Version 1.20 - BuildID: VVE120C ------------------------------------------------- Problem(s) Fixed: - Invalid slot usage state showed on RENAI Riser card. - Incorrect slot error event on JOJO Riser. - Fail to return to Boot menu if boot fail. - Further updates to the fatal error handler to report QPI errors during runtime. - iSCSI Attempt will disapper when system reboot several times. - F6 function key is malfunction. - Remove unnecessary information from ReadMe file. - Fails to report logging limit errors on spared DIMM. - FAN speed is pull up if TXT enabled in uEFI. - Fail on Windows 2012 TPM WHQL validation.
Enhancements: - Improve 2DPC@1333MHz detection algorithm. - Improve CPU detect algorithm. - Support 4GB PCI inventory access. - Support UDIMM 2DPC@1333MHz run on 1.35V by automatic. - Remove unnecessary warm reset to improve uEFI boot time.
Limitations: Dependencies:
Version 1.11 - BuildID: VVE116C ------------------------------------------------- Problem(s) Fixed: - Fail to install VMWare 5.0 if Intel TXT function is enabled.
Enhancements: Limitations: Dependencies:
Version 1.10 - BuildID: VVE116A ------------------------------------------------- Problem(s) Fixed: - Fixed issue to allow PXE/iSCSI to be configured out-of-band - Processor speed is incorrect when system is idle w/ E5-2637 M1. - Serial Console Redirection function can not work if SP Redirection is Disabled. - No Screen output by Serial Over Lan connection. - Fix Intel E5-2637 speed is incorrect. - DIMM slot 13-24 can NOT indicate which memory was falut. - Fix SMBios Type 4 External Clock information incorrect. - Fixed issue that caused the ASU tool to occasionally fail to update the Processors.CoresinCPUPackage value
Enhancements: - Improve PCIe error reporting. - Improve Fatal Error Handle. - Improve Legacy PXE function. - Remove Intel 130W CPU limitation. - Improve PCIe error reporting. - Support Heping riser card - Improve ME Update mechanism - Improve ACPI: C-States - Added support for using Features On Demand with Optimized Boot enabled - Updated thermal threshold values for DIMMs - Reduce boot time (reduce unnessary reset in POST).
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.22.00 Build ID: IBM12200 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.22.00 - Update Utility release for IBM x86 servers.
Note: *- Only keep the legacy HDD/SSD in this Update program, the drives were out of production by 4Q2014 or no firmware changes since 1Q2014. No FW update for below legacy drives in this version.
This package acknowledges support and may include updates for drives with product ID strings of:
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.21.00 Build ID: IBM12100 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.21.00 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5K
- ST2000NM0043, ST4000NM0043 to EC5H
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6E
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC6E
- HUS724020ALS64, HUS724030ALS64, HUS724040ALS64 to MPXSJ3LA
- HUS724020ALS61, HUS724040ALS61 to MPXSN3LA
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to VCXSA810
SAS 2.5"
- HUC156030CSS20, HUC156060CSS20 to KFXSJ2G8
- HUC101212CSS60 to CPXSJ2MC
- HUC101212CSS61 to CPXSN2MC
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to CEXSJ2EL
- HUC109030CSS61, HUC109060CSS61, HUC109090CSS61 to CEXSN2EL
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to SPXSJ4CC
- HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to SPXSN4CC
SATA 3.5"
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD40
- ST2000NM0024, ST4000NM0024, ST6000NM0024, ST5000NM0024 to BB67
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5G
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB47
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA35
- STECM8PSB2 to 2864/SM08
SATA 1.8"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB47
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.20.00 Build ID: IBM12000 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.20.00 - Update Utility release for IBM x86 servers.
Note: *- Update the firmware on SAS/SATA SSDs to fix PSIRT issue with Intel SSD's.
This package acknowledges support and may include updates for drives with product ID strings of:
SATA 2.5"
- SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB480G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA39.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I, SSDSC2BB800G4I to D201NE40.
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC34.
SATA 1.8"
- SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to D201NE40.
- SSDSC1NA200G3I, SSDSC1NA400G3I to 5DV1NA39.
- SSDSC1NB800G4I to D201NE40.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.19.06 Build ID: IBM11906 ************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.19.06 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
- Remove TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I from FW update utility for new code updating break Raid.
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program. Version 1.18.03 Build ID: IBM11803
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.18.03 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read.
RETAIN TIP: H214635 MIGR-5098037
SAS 3.5"
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6B - similar to Note * above.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5J - Enhance Dither Algorithm to prevent dwelling during Idle environments. - ST2000NM0043, ST4000NM0043 to EC5E - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SAS 2.5"
- TXA2E21600GA6I to GB7P - add support in profile.
- HUC156030CSS20, HUC156060CSS20 to J2G6 - add support in profile.
SATA 3.5"
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB66 - similar to Note * above.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5F - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SATA 2.5"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB42 - add support in profile.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I to D201NB39 - add support in profile.
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read. RETAIN TIP: H214635 MIGR-5098037
This package acknowledges support of qualified devices and may include updates for drives with product ID strings of:
SAS 3.5"
- HUS724020ALS61, HUS724040ALS61 to N3L6 - internal updates.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5H - See Note * above.
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC66 - see Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- Other drive codes are present for support identification.
SAS 2.5"
- WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA34 - follow-on release. - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC33 - follow-on release.
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EH - follow-on release.
- TXA2D20200GA6I, STXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I to GB7P - enhancements.
- ST300MM0006, ST600MM0006, ST900MM0006 to B56T - See Note * above.
- ST300MM0026, ST600MM0026, ST900MM0026 to E56E - See Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- ST1200MM0007 to B57E - See Note * above.
- ST1200MM0017 to E577 - See Note * above.
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to J4C8 - See Note # above - HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to N4C8 - See Note # above
- Other drive codes are present for support identification.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1D - performance inhancements.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5C - See Note * above.
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB65 - See Note * above.
- WD2003FYYS-23W0B0 to WA36 - configuration additions.
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD39 - configuration additions.
- HUA723030ALA6 to MKAOA930 - enhancements. - HUA723020ALA6 to MK7OA930 - enhancements.
- Other drive codes are present for support identification.
SATA 2.5"
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA34 - ship level.
- Other drive codes are present for support identification.
SATA 1.8"
- Drive codes are present for support identification.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.05 Build ID: IBM11605
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.05 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4B - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L6 - Fixed unexpected 02/04/11 error; Fixed a drive logic self-initiated reset on read/write long commands; Fixed a problem with large write sequential transfers.
SAS 2.5"
- ESXSST9500620SS, ESXSST91000640SS to BD2K - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
SATA 2.5"
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.04 Build ID: IBM11604
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.04 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB42 - > A drop in host power supply may cause bad block growth > The bad block table may not properly increment > Background activity may continue after STANDBY, STANDBY IMMEDIATE, or SLEEP > ID173/202 may show incorrect value when the NAND erase count exceeds 3000 > Changed DRAM timing > Event log may be programmed when supply voltage from host is out of specification
- SSDSC2BB012I4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix that corrects a condition that may cause the drive to not respond.
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND34 - will require two update runs and system reboots for device fw update to complete--Please See the limitations in readme for details.
> Performance improvement on sub-4KB sequential write > Fix drive reports higher than actual data units read and write > Fix drive incorrectly counts unsafe power shutdown events on warm reboots
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.03 Build ID: SAS11603
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.03 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST2000NM0034, ESXSST4000NM0034, ESXSST6000NM0034 to BC67 - GA code. - ESXSST2000NM0054, ESXSST4000NM0054, ESXSST6000NM0054 to EC66 - GA code.
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA39 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SAS 2.5"
- ESXSTXA2D20200GA6, ESXSTXA2D20400GA6, ESXSTXA2D20800GA6, ESXSTXA2E21600GA6 to GB7P - fixes implemented to support PI issues.
- ESXSST300MP0005 to B675 - GA code. - ESXSST300MP0025 to E671 - GA code.
- ESXSST300MP0035, ESXSST600MP0035 to B683 - GA code. - ESXSST300MP0045, ESXSST300MP0045 to E685 - GA code.
- ESXSST300MX0012, ESXSST600MX0052 to BH53 - GA code.
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23DS to ZA34 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; drive was reporting 0B/11 instead of 03/11. - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC33 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1C - GA code
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE2B - Update configuration change.
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB34 - > Some Out of Range LBAs accepted by NCQ commands where they should be aborted. > SataDownShift.srt failed, Smart attribute Raw lost with perform dirty pwr cycle . > Low Power Entry Bug Identified from Marvell Code Review > Track Timeout, Marvel 373 sequencer issue > Unreasonable ECC count in SMART ID 195
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program for Linux. Version 1.16.00 Build ID: SAS11600
******************************************* IBM SAS/SATA HDD/SSD Update Program Version 1.16.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37 - Resolves drive initiated reset (DBS (Debug Stop event)) encountered under a narrow timing window (~1ns) for specific command/access patterns, due to the drive’s handling of command automation where it was possible for an internal hardware resource conflict to occur between two tasks.
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NSto BE2A
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA37
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND32 - will require a system reboot for device fw update to complete.
********************************************************************* SAS/SATA HDD/SSD Update Program Version 1.15.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37
- ST9500620NS, ST91000640NS to BE2A
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9500620NS, ST91000640NS
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA36
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
NOTE TO SERVICE - Reference RETAIN TIP H29851 ******************************************* SAS Hard Disk Drive Update Program Version 1.14.04 Critical Release Reference RETAIN TIP H29851
This package includes updates to drives with product ID strings of:
SAS 2.5"
Initial code Release - SMK3001GRDB, SMK6001GRDB, SMK9001GRDB to SB35
SATA 2.5"
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA36 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB37 - fix to prevent possible drive lock up during format.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA36 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB37 - fix to prevent possible drive lock up during format.
=================================================================== IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to E568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX
ibm_fw_hddlegacy_sas-1_22_00_linux_32-64_chg
IBM 7383 (IBM system x 3500 M4) uEFI Flash Update Version 2.20 (BuildID Y5E150BUS) Change History
Version 2.20 - BuildID: Y5E150B ------------------------------------------------- Problem(s) Fixed: - Fixed a potential Setup Screen format problem when configuring a RAID adapter. Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 2.01 - BuildID: Y5E146B ------------------------------------------------- Problem(s) Fixed: - Fixed OpenSSL vulnerabilities as reported in CVE Advisories: CVE-2015-1793, CVE-2015-1789, CVE-2015-1790, CVE-2015-1792
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.92 - BuildID: Y5E144C ------------------------------------------------- Problem(s) Fixed: - Updated UEFI to address these vulnerabilities: CVE-2015-0209, CVE-2015-0286, CVE-2015-0287, CVE-2015-0288, CVE-2015-0289 - X3500M4 High FAN speed issue with NETXTREME adapter Card - Whenever a PCIe adapter was inserted on slot 1, the SLOT information SHOWS PCI-X type Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.82 - BuildID: Y5E142C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.70 - BuildID: Y5E140A ------------------------------------------------- Problem(s) Fixed: - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: Y5E136A ------------------------------------------------- Problem(s) Fixed: - Can not boot up from IMM Remote Mount with USB key. - Fixed the Incorrect Uniphy Recipe programmed for S-step IVX Enhancements: - Variable store self-healing. Limitations: - When flashing UEFI from version 1.30 or later than 1.20 to version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO50D Version: 3.65 (ibm_fw_imm2_1aoo50d-3.65_anyos_noarch) or higher prior to installing UEFI version 1.60. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features implemented in this release.
Version 1.51 - BuildID: Y5E134G ------------------------------------------------- Problem(s) Fixed: - Fixed system unexpected power off with sensor planar voltage fault - Fixed Performance drop issue
Enhancements: - The 2DPC@1866 especially for 16G DIMM formal code Limitations: Dependencies:
Version 1.50 - BuildID: Y5E134F ------------------------------------------------- Problem(s) Fixed: - Corrected IPv6 reboot problems - Corrected 64bit resouce allocation problems - Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot Enhancements: - Add support for Intel Xeon processor E5-2600 v2 product family - Add notification when UEFI detects GPT corruption during POST - Add support to configure the "Next Boot to F1 setup" function out of band - Add long text support in F1 setup help string Limitations: Dependencies:
Version 1.40 - BuildID: Y5E128D ------------------------------------------------- Problem(s) Fixed: - Incorporated Microcode Update (MCU) M6D206D7_00000710 to address Intel Erratum BT248 for System Resets with 32-bit (PAE Enabled) Guest OS and VT FlexPriority enabled. For more information, refer to IBM RETAIN Tip H21370. Enhancements: Limitations: Dependencies:
Version 1.40 - BuildID: Y5E128B ------------------------------------------------- Problem(s) Fixed: - Fixed that can not enter F1 setup menu after 3x POST failure occurred. - Correct the PCIE link control of Active-State Power Management(ASPM) setting to result the PCI/NMI problem - Fix that UA-101 audio device hang at legacy mode Enhancements: - Multiple PCIe adapter BARs - Configurable MMIO base - Support Firmware first feature - Add informational messages when existing UEFI F1 setup menu - Add OEM SPD feature - Improved handling of memory in high stress application/usage Limitations: Dependencies:
Version 1.30 - BuildID: Y5E124B ------------------------------------------------- Problem(s) Fixed: - UEFI option 43 fails to work - Disable phase shedding and Default to disable CPU C-states - ITP can't trigger CPU2 IERR - MBE WHEA-log can't match ECC Uncorrectable event Enhancements: - Change UDIMM 2DPC@1333Mhz 1.35V algorithm to meet performance specification requirement - Support ROM Recovery feature (Auto Promotion under Backup Bank Management Method) Limitations: Dependencies:
Version 1.20 - BuildID: Y5E120D ------------------------------------------------- Problem(s) Fixed: - Sevaral uEFI OS boot failed with F12 boot menu HDD0. - Console Switch 1754A2X with KB & Mouse are not responding in EFI Web BIOS - Fail to return to Boot menu if boot fail. - IMM menu location is changed. - F6 function key is malfunction. - FAN speed is pull up if TXT enabled in uEFI. Enhancements: - Support the Trusted Computing Group's Memory Overwrite Request function. - Improve fatal error handler to report QPI errors during runtime. - Support FastSetup feature - Enable DRAM phase shedding - Support 4GB PCI inventory access. - Support UDIMM 2DPC@1333MHz run on 1.35V by automatic. - Improve messages while booting up. - Enable Phase Shedding to improve memory performance. - Improve PCIe Slot# for WidgetGetDeviceLocation procedure - Remove unnecessary warm reset to improve uEFI boot time.
Limitations: Dependencies:
Version 1.10 - BuildID: Y5E116A ------------------------------------------------- Problem(s) Fixed: - Fixed E5-2690 cannot run frequency at 2.9GHz(only 2.8GHz) when turn off Turbo mode. - Fixed fnstruction for TPM enablement has type error. - Fixed CPU can not enter deep C status with uEFI 11I under RHEL5.7 64 - Fixed failed to boot from CDDVD ROM with uEFI OS - Fixed iSCSI ISID mismatch under uEFI BIOS Settings. - Fixed TCG TPM Integration Test (Manual) random failed under WIN2K8 R2 SP1 with uEFI_11L - Fixed QPI link speed and Turbo mode show incorrect with M1 stepping CPU. - Fixed the format of System Event Log is uncorrected - Fixed Legacy Thunk Support is malfunctional - Fixed DIMM slot 13-24 can NOT indicate which memory was falut when trigger MBE on Mirror mode by bugged DIMM - Fixed ASUT74H can't find any iscsi item - Fixed Fail to set some of PXE items with ASU76h - Fixed Can not boot into WinPE in RAID HDD on Crossfield - Fixed Personality can not be switched in OCM tool no matter FOD is imported - Fixed fail to set some of PXE items with ASU76h - Fixed Processor speed is incorrect when system is idle - Fixed VLAN ID can be configured to ID 0 - Fixed Processor speed is incorrect when system is idle w/ E5-2637 M1 - Fixed Console redirection can not work normally with com2com. - Fixed No screen output with SOL connection Enhancements: - Added Legacy Thunk support setup item - Change Operating Mode from Custom Mode to Efficiency - Favor Performance - Added DriverCodeDisplay error code on screen function - Improve PCIe error reporting. - Improve Fatal Error Handle. - Improve Legacy PXE function. - Remove Intel 130W CPU limitation. - Improve PCIe error reporting. - Support Heping riser card - Improve ME Update mechanism - Improve ACPI: C-States - Added support for using Features On Demand with Optimized Boot enabled - Updated thermal threshold values for DIMMs - Reduce boot time (reduce unnessary reset in POST). Limitations: Dependencies:
TMM Firmware Update for ServeRAID M5100 Series SAS/SATA Controllers
Adapters Supported: ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.01.02 - ------------------- TMMB: 70-25842-12 - Fixed issue where update may fail to install
Version 1.01 - Initial release ------------------- TMMB: 70-25842-12 - Fixed issue where CVPM could report "Relearn timeout" during a relearn cycle (Retain Tip H183319) ibm_fw_sraidmr_5100-tmm-1_01_02_linux_32-64_chg
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers
Adapters Supported: ServeRAID M5225-2GB SAS/SATA Controller ServeRAID M5210e SAS/SATA Controller for IBM System x ServeRAID M5210 SAS/SATA Controller
NOTE TO SERVICE - Reference RETAIN #N/A
Version 24.12.0-0039 --------------------
Version 24.12.0-0034 --------------------
Version 24.12.0-0033 --------------------
Version 24.12.0-0028 --------------------
Version 24.12.0-0024 - High Impact/High Probability of Occurrence --------------------
Fixes: - Fixed the potential of a data miscompare that was observed only at a vendor test facility under very heavy I/O and abnormal practices (SCGCQ00990093, Port of SCGCQ00976904) - Fixed an issue where performing back-to-back target resets on the same JBOD may results in an Controller Reset (SCGCQ00857181) - Fixed an issue where firmware may allow a Reconstruction to be performed when Pinned Cache is present (SCGCQ00857692) - Fixed an issue where "MonTask" error may occur when importing a Foreign Configuration (SCGCQ00860066) - Fixed an issue where controller does not Stop on Error and boots into Operating System when Pinned Cache is present(SCGCQ00860503) - Fixed an issue where firmware allows CacheCade Virtual Drive deletion when Pinned Cache is present (SCGCQ00871973) - Fixed an issue where a firmware downgrade FW downgrade may fail when IO and Background Operations are being performed (SCGCQ00873239) - Fixed an issue where error "Core 0 exception in line 245 in ../../raid/1078int.c" may occur when Target Reset sent to Physical Disks in parallele with Background Operations (SCGCQ00878554) - Fixed an issue where error "Assertion failure in ../../dm/src/dmDrvPrep.c at line 836" may occur (SCGCQ00879198) - Fixed an issue where firmware may hang on Task Abort (SCGCQ00881901) - Fixed an issue where iPtr and rPtr values may be greater than the size of the buffer (SCGCQ00886685) - Fixed an issue where more IOs were allowed than the available buffer could support (SCGCQ00894472) - Fixed an issue where the Operating System may become unresponsive after creating multiple sliced Virtual Disks (SCGCQ00894608) - Fixed an issue where adapter may reset under certain conditions (SCGCQ00895554) - Fixed an issue where error "line 1271 in file ../../raid/1078dma.c" may occur when running FastPath with CacheCade (SCGCQ00898799) - Fixed an issue where forceCacheFlush was occurring in an iMR context where it doesn't apply (SCGCQ00899762) - Fixed an issue where importing 240 Virtual Drives may cause a firmware fault (SCGCQ00900601) - Fixed an issue where error "line 229 in file ../../raid/mtask.c" may occur when Hibernating Windows 10 (SCGCQ00905864) - Fixed an issue where importing a Foreign Configuration may fail (SCGCQ00908325) - Fixed an issue where FastPath IO may not time out properly (SCGCQ00910124) - Fixed an issue where StorCLI may report an incorrect ScapBatVersionNO when using command "/c0/cv show all" (SCGCQ00914343) - Fixed an issue where some default values may not be picked up for unchanged controller properties sharing the same byte (SCGCQ00914740) - Fixed an issue where chain mid allocation for JBOD may fail (SCGCQ00915081) - Fixed an issue where configuration creation may fail after creation of a CacheCade Virtual Drive followed by JBOD creation (SCGCQ00917307) - Fixed an issue where a cable pull during a Target Reset on JBOD may result in a data TLB error (SCGCQ00923289) - Fixed an issue where controller may become unresponsive after hitting an OCM error(SCGCQ00924986) - Fixed an issue where the Physical Device map was being updated unnecessarily (SCGCQ00927173) - Fixed an issue where some drives could not be discovered successfully (SCGCQ00927792) - Fixed an issue where attempting to stop a Drive Erase operation from application may cause firmware to hang (SCGCQ00928150) - Fixed an issue where controller disappears when performing a cable pull (SCGCQ00928333) - Fixed an issue where CacheCade Virtual Drive creation may fail with false error (SCGCQ00930044) - Fixed an issue where controller may hang when importing a drive into a RAID0 CacheCade Virtual Drive (SCGCQ00934196) - Fixed an issue where firmware would not allow an Online Firmware Update (SCGCQ00936693) - Fixed an issue where error "line 219 in file ../../raid/mficmd.c" may occur when powering system on from S3 sleep (SCGCQ00937487) - Fixed an issue where error "MonTask: line 1281 in file /raid/1078dma.c" may occur when running enclosure cable pulls with CacheCade Virtual Drive (SCGCQ00941531) - Fixed an issue where firmware recovers invalid cache after firmware update (SCGCQ00944012) - Fixed an issue where LdInitPdDone did not include flush command block (SCGCQ00945033) - Fixed an issue where driver may panic and controller may reset on medium errors with Pinned Cache (SCGCQ00948257) - Fixed an issue where Virtual Drives don't revert back to Write-Back once the controller Pinned Cache is destaged (SCGCQ00948466) - Fixed an issue where firmware may fault when running full initialization on Virtual Drives with LDBBM entries created during Consistency Check (SCGCQ00952627) - Fixed an issue where a SES Discovery Error may occur on repeated retries for some expanders (SCGCQ00976741) - Fixed an issue where the drive bay LED may not turn off when the drive is removed (SCGCQ01003387) - Fixed an issue where error "MonTask: line 4946 in file ../../raid/ld.c" may occur when multipath cable pull occurs Patrol Read (SCGCQ00857528) - Fixed an issue where Locate LED turns off when cable failover performed (SCGCQ00869681) - Fixed an issue where "Watchdog Timer Exception" error followed by firmware fault after initiating Physical Drive erase operation (SCGCQ00872140) - Fixed an issue where a firmware fault occurs when issuing Task Management commands on 240 JBODs while running IO (SCGCQ00872889) - Fixed an issue where Virtual Drive deletion could cause IO freeze time to increase (SCGCQ00873201) - Fixed an issue where a data TLB error would occur after issuing task abort (SCGCQ00873991) - Fixed an issue where "MonTask" error may occur due to a Full-Disk Encryption / Self-Encrypting Disk that fails to spinup (SCGCQ00874332) - Fixed an issue where error "adapter at baseport not responding" may occur (SCGCQ00880919) - Fixed an issue where cache is not flushed immediately upon firmware recieving the cache-flush out-of-band command (SCGCQ00882125) - Fixed an issue where IO may slow while deleting Virtual Drives (SCGCQ00891924) - Fixed an issue where IO halts on JBODs with "read/write error" when the target drives are reset in Linux (SCGCQ00893588) - Fixed an issue where "MonTask: line 1413 in file ../../raid/config.c" may occur when creating a CacheCade Virtual Drive (SCGCQ00894610) - Fixed an issue where firmware does not log controller property change event for enabling/disabling 240VD feature (SCGCQ00895577) - Fixed an issue where event length may come up as 0 (SCGCQ00897406) - Fixed an issue where firmware was not seding the proper status for aborted commands (SCGCQ00900250) - Fixed an issue where controller firmware may fault during Hibernation or when the driver loads twice (SCGCQ00902938) - Fixed an issue where firmware may fault after creating 240 Virtual Drives and rebooting the server (SCGCQ00905416) - Fixed an issue where progress for CacheCade disassociation activity is not displayed for all source Virtual Drives (SCGCQ00906846) - Fixed an issue where error "Assert at line 1181 mpthostcmd.c" may occur when FastPath has been disabled or for a timeout IO (SCGCQ00910006) - Fixed an issue where error "LMID HS-FIFO Error 0x8" may occur when removing a redundant path to a JBOD with IO (SCGCQ00914274) - Fixed an issue where applications may show incorrect value for Max Parallel Commands field of Controller Information in iMR(SCGCQ00914751) - Fixed an issue where firmware was failing ABORT TASK and ABORT TASK SET commands on SATA JBOD (SCGCQ00915088) - Fixed an issue where exception may occur on Online Controller Reset (SCGCQ00917523) - Fixed an issue where "MonTask" error may occur in a drive removal or multipath removal scenario (SCGCQ00919229) - Fixed an issue where the wrong MFI_STAT is returned from PdDcmdSysPdMapAbort (SCGCQ00930593) - Fixed an issue where an Online Firmware Update may fail when downgrading from firmware that supports 240 Virtual Drives to firmware that does not (SCGCQ00930917) - Fixed an issue where "DM_EnableFastPathOnDevice :: FP enabled on devhandle" may be printed in logs even though FastPath is enabled (SCGCQ00936617) - Fixed an issue where "C0:Index 0098 allocated from pool 3" prints continuously in log with 12Gbps Enclosures and SATA drives (SCGCQ00937572) - Fixed an issue where firmware prematurely rejects ONFI flash module (SCGCQ00937617) - Fixed an issue where SafeID may change on repeated queries using StorCLI (SCGCQ00941577) - Fixed an issue where firmware may fault when importing Virtual Drives with Pinned Cache (SCGCQ00949440) - Fixed an issue where Write-Back Virtual Drives are converted to Write-Through on system reboot or Online Controller Reset(SCGCQ00859720) - Fixed an issue where a Data TLB error may occur when firmware is upgraded or downgraded (SCGCQ00867065) - Fixed an issue where a Data TLB error may occur when aborting a host command (SCGCQ00874357) - Fixed an issue where firmware may fault when running IO with Task Resets on JBODs (SCGCQ00877673) - Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur while running IO with 64 Virtual Drives and removing drives belonging to CacheCade (SCGCQ00878587) - Fixed an issue where cache flush was occurring during Virtual Drive deletion (SCGCQ00878923) - Fixed an issue where IO dip is seen when deleting Virtual Drives (SCGCQ00879193) - Fixed an issue where a Data TLB error may occur when sending Target Reset on JBOD via out-of-band commands (SCGCQ00881919) - Fixed an issue where perTunerMode is not set correctly after a controller reset (SCGCQ00882897) - Fixed an issue where error "MonTask: line 2735 in file ../../ssd/ssd_cache_fw.c" may occur when error are injected repeatedly (SCGCQ00887019) - Fixed an issue where a rebuild cannot be started for a degraded CacheCade Virtual Drive after heavy IO (SCGCQ00887428) - Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur with IOs on maximum Virtual Drives configured and Background Opertations are occurring (SCGCQ00890133) - Fixed an issue where Patrol Read doesn't resume after Consistency Check completes after a system reboot (SCGCQ00894344) - Fixed an issue where StorCLI throws an error when performing "/c0/vx show all" after a Full Initialization on RAID1 Virtual Drive with SSDs (SCGCQ00904899) - Fixed an issue where a firmware fault occurs when a copyback operation fails to start (SCGCQ00904905) - Fixed an issue where LUID is changed when importing a non-240VD configuration to a 240VD firmware (SCGCQ00907658) - Fixed an issue where a "MonTask" error may occur when under heavy JBOD IO and the JBOD IOs begin failing (SCGCQ00915078) - Fixed an issue where error "line 1279 in file ../../raid/1078dma.c" may occur on iMR firmware during boot (SCGCQ00915092) - Fixed an issue where controller reset occurs under stress with 240 Virtual Drives configured (SCGCQ00915398) - Fixed an issue where Online Firmware Update would fail due to driver reload issues (SCGCQ00915454) - Fixed an issue where a Data TLB error may occur during reconstrution operation when Target Resets are issued to JBODs (SCGCQ00921993) - Fixed an issue where "Core 0 exception" is seen when trying to import Foreign Configurations with Pinned Cache (SCGCQ00863880) - Fixed an issue where CTRL-R interface does not show correct port information when hotplugging enclosure paths (SCGCQ00866487) - Fixed an issue where firmware may fault when an enclosure with an especially slow drive is present (SCGCQ00867120) - Fixed an issue where error "MonTask: line 1280 in file ../../raid/1078dma.c" may occur on out-of-band command timeout (SCGCQ00872875) - Fixed an issue where error "Assertion failure in ../../raid/cache.c at line 774" may occur after pulling out an enclosure cable (SCGCQ00878097) - Fixed an issue where write performance drops in RAID5, Write-Through, No Read-Ahead, Stripe Size 64, 1MB IO at queue depth 128/256 (SCGCQ00878414) - Fixed an issue where an imported 4K-drive RAID0 becomes Unconfigured Good on reboot (SCGCQ00895689) - Fixed an issue where Online Firmware Update fails with "not supported" message (SCGCQ00915073) - Fixed an issue where Logical Drive IO for FastPath-capable RAID0/RAID1 were not handled properly in the presence of a RAID5/RAID6 Write-Through volume running sequential write streams (SCGCQ00915409) - Fixed an issue where a CRC mistmatch and Invalid Log Event are surfaced when checking Controller Properties in parallel with a Learn Cycle (SCGCQ00919945) - Fixed an issue where performance drops are seen on writes to RAID1 FastPath volumes (SCGCQ00931895) - Fixed an issue where event messages reporting CacheCade Virtual Disk target ID and remaining CacheCade size are incorrect (SCGCQ00864019) - Fixed an issue where firmware faults when using an Online Controller Reset from StorCLI after having issued "supportResetNow" (SCGCQ00878150) - Fixed an issue where an "Exception in Core -0" error may occur on iMR firmware under VMWare (SCGCQ00904103) - Fixed an issue where "MsgAlloc: No free messages, poolIndex=4" may appear in logs while running IO on JBODs (SCGCQ00908982) - Fixed an issue where the TTY log dump is not persistent across multiple boots (SCGCQ00877100) - Fixed an issue where drives that return errors for all protocol commands may be retried indefinitely (SCGCQ00805369) - Fixed an issue where setting the Learn Cycle property of iBBU09 gives an i2C error (SCGCQ00837206) - Fixed an issue where driver may hang with LSI2008-based adapters (SCGCQ00843390) - Fixed an issue where device wait queue is not cleared when drive is no longer online (SCGCQ00878401) - Fixed an issue where Windows may BSOD on firmware upgrade when running driver 6.707.08.00 (SCGCQ00886272) - Fixed an issue where disableImmediateIO NVDATA value is not honored by firmware (SCGCQ00886666) - Fixed an issue where Foreign Configuration could be cleared even when Pinned Cache is present (SCGCQ00889209) - Fixed an issue where a Virtual Drive under Reconstruction may go Degraded if the drive being reconstructed is removed before the operation completes (SCGCQ00891282) - Fixed an issue where a "MonTask" error may occur after initiating a RAID Level Migration (SCGCQ00891288) - Fixed an issue where system hang may occur after aborting running Consistency Checks repeatedly (SCGCQ00895265) - Fixed an issue where a "MonTask" error may occur after creating 240 Virtual Drives and rebooting the server (SCGCQ00908121) - Fixed an issue where LUID is changed when importing a non-240VD configuration to 240VD-enabled controller (SCGCQ00908153) - Fixed an issue where a Virtual Drive may disappear on reboot if created with drives from a previously-deleted Virtual Drive (SCGCQ00914823) - Fixed an issue where device wait queue is not cleared if a drive is no longer online (SCGCQ00923279) - Fixed an issue where message "Found invalid event at fc4966ec" is printed in firmware log every 5 seconds (SCGCQ00931370, SCGCQ00979910) - Fixed an issue where firmware is unable to detect all Virtual Drive's "Degraded" status for partial Virtual Drives created on the same Physical Drives (SCGCQ00942380) - Fixed an issue where driver may panic and firmware may hang when medium errors are present (SCGCQ00954118) - Fixed an issue where firmware does not discard dirty cache after firmware update (SCGCQ00992657) - Fixed an issue where some Recoverable Errors were marked as Unrecoverable (SCGCQ01015699) - Fixed an issue where HII and Ctrl-R show an incorrect message when trying to import a 65th Virtual Drive (SCGCQ00803718) - Fixed an issue where Functional Level Reset (FLR) was not supported (SCGCQ00843936) - Fixed an issue where Write-through and Write-back cache policies can be changed via Windows Logical Disk Properties. (SCGCQ00883311) - Fixed an issue where many "LdDcmd ***** return pinned list 0" messages may be printed in firmware log (SCGCQ00895459) - Fixed an issue where an alert is repeated twice for Cancel Consistency Check on Virtual Drives (SCGCQ00900027) - Fixed an issue where error "Controller encountered fatal error and was reset" may occur under heavy IO and background operations (SCGCQ00905603) - Fixed an issue where CacheCade-related 240 Virtual Drive checks were not checking controller properties (SCGCQ00905809) - Fixed an issue where out-of-band applications may not display Show Configuration Summary when 240 Virtual Drives are created (SCGCQ00908237) - Fixed an issue where a RAID0 using 4k drives may not be visible after reboot (SCGCQ00999181) - Fixed an issue where firmware may not poll all temperature sensor channels every 5 seconds (SCGCQ00844152) - Fixed an issue where Hard Drive RAID0 and RAID10 performance at 1M stripe size is suboptimal between queue depths of 16 to 256 (SCGCQ00876154) - Fixed an issue where StorCLI will report Success when flashing an MR-only package on an iMR-only controller (SCGCQ00882149) - Fixed an issue where 'Fw initializing devices' may hang with specific failed drives (SCGCQ00884719) - Fixed an issue where controller may report cache size as "0" when no logical drives are present (SCGCQ00891273) - Fixed an issue where a Physical Disk may not go to Online state even after creating a Virtual Drive on it (SCGCQ00910741) - Fixed an issue where error "SAS core detected EEDP error in application tag" may occur (SCGCQ00936647) - Fixed an issue where "storcli /c0 show all" shows many Bad Block messages in the log (SCGCQ00892136) - Fixed an issue where firmware may log Controller Properties Changed events twice (SCGCQ00908238) - Fixed an issue where a Virtual Drive under Reconstruction may be set Degraded if the drive under reconstruction is removed (SCGCQ00922677) - Fixed an issue where firmware may enter fault state after system power cycle with an SSD drive (SCGCQ00835227) - Fixed an issue where firmware may fault and RSOD may occur when a Virtual Drive is deleted when a Reconstruction is in progress on a PI-enabled VD combined with a slow initialization on another Virtual Drive (SCGCQ00872263) - Fixed an issue where firmware doesn't report no SMART error when a Predictive-Failure Analysis (PFA) drive is present (SCGCQ00841772) - Fixed an issue where firmware may not detect inserted drives (SCGCQ00876142)
Enhancements: - Added support for restarting Patrol Reads after they are interrupted by a Consistency Check (SCGCQ00883176) - Added ability to enable and disable 1M IO support via controller property (SCGCQ00893029) - Added support for Task Management for JBOD/sysPDs (SCGCQ00855457) - Reduced Command Block latency during Background Operations (SCGCQ00865372) - Added ability to not moe Write-back Virtual Drives to Write-through when Pinned Cache is less than 50% of available buffers (SCGCQ00852502) - Updated iMR queue depth to 928 (SCGCQ00888862, SCGCQ00930846, SCGCQ00896497) - Disabled SATA HOQ support for iMR controllers (SCGCQ00942547) - Added Task Management support for JBOD/sysPD (SCGCQ00861819, SCGCQ00855457) - Re-enabled 1M IO support (SCGCQ00874200) - Added support for Event Reporting for SuperCap Health after Learn Cycles (SCGCQ00894455)
Version 24.12.0-0020 --------------------
Version 24.9.0-0029 -------------------
Version 24.9.0-0026 - High Impact/High Probability of Occurrence -------------------
Fixes: - Fixed an issue in iMR mode where "Controller encountered fatal error and was reset" errors can occur under heavy IOs and background operations (SCGCQ00894643) (RETAIN Tip H001154) - Fixed an issue where driver health protocol may report unhealthy if more than 64 VDs are configured (SCGCQ00830918) - Fixed an issue where VDs beyond 64 may not be reported in legacy OpROM pOST display list (SCGCQ00826174) - Fixed an issue where "StorCLI /cX add VDs detailed" menu provides incorrect syntax for R1E (SCGCQ00501437) - Fixed an issue where CLI "show all" command fails with error "Error! App exec failed in FW PCLIError! Internal" (SCGCQ00518543) - Fixed an issue where the dedicated hot spare option in HII may be grayed out for RAID1 under the profile based configuration menu (SCGCQ00873973) - Fixed an issue where HII drive management and enclosure management may report only port 4-7 connected when ports 0-3 and 4-7 are connected to the same expander (SCGCQ00870398) - Fixed an issue where HII may hang or multiple enclosure entries will be seen in enclosure eanagement form after repeated navigation (SCGCQ00878350) - Fixed an issue where a 15-character VD name is truncated to 14 characters (SCGCQ00854606) - Fixed an issue where profile-based VD creation menu doesn't explain each profile's drive selection criteria (SCGCQ00884229) - Fixed an issue where some overlap may be seen during legacy OpROM pOST when more than one controller is present and there are boot messages for the second controller (SCGCQ00866982) - Fixed an issue where MSM may display "The requested command has invalid arguments" when 'Schedule Consistency Check' is selected (SCGCQ00832908) - Fixed an issue where a controller may not be accessible through RAIDLink until the OS is up and running (SCGCQ00847001) - Fixed an issue where drive firmware on certain SED/FDE SATA SSDs could not be updated (SCGCQ00856977) - Fixed an issue where an error "MonTask: line 1272 in file ../../raid/1078dma.c" may occur while running IO in a virtual machine (SCGCQ00822403) - Fixed an issue where a JBOD PD may not be able to be converted to Unconfigured Good in Solaris (SCGCQ00834552) - Fixed an issue where an "Instruction TLB" error may occur when a StorCLI /cX set autopdcache=r0 or similar command is executed (SCGCQ00835586) - Fixed an issue where firmware may hang in multipath scenario when cable pull/push test is performed at the same time as an array property change is issued (SCGCQ00836496) - Fixed an issue where a secure erase on a SATA SSD in HII may fail or lead to a hang in HII (SCGCQ00841317) - Fixed an issue where the controller may reset in some situations with media errors and VD undergoing manual rebuild after drives are taken offline, under stress (SCGCQ00825126) - Fixed an issue where the 3x08 chip Errata ID - 2012-RC714 may lead to PCIE 3.0 hot reset non-compliance (SCGCQ00829129) - Fixed an issue where rebuild performance on RAID1 is always slower than other RAID configurations (SCGCQ00841359) - Fixed an issue where patrol read properties window won't show up in MSM (SCGCQ00797676) - Fixed an issue where an L2 unrecoverable cache error may be seen during patrol read properties modification when VDs are made offline (SCGCQ00847162) - Fixed an issue where a VD erase may not resume after reboot when a CacheCade VD is present (SCGCQ00851810) - Fixed an issue where controller boots to OS even when pinned cache is present and boot error handling is set to stop on error (SCGCQ00860503) - Fixed an issue where firmware cannot detect some newly-inserted drives (SCGCQ00860270) - Fixed an issue where "MonTask: line 1518 in file ../../raid/2108vI2o.c" may occur in conjunction with a VMWare Guest abrupt shutdown (SCGCQ00852670) - Fixed an issue where connector name field is displayed as port 4-7 when actually both ports 0-3 and 4-7 are connected (SCGCQ00868215) - Fixed an issue where "line 243 in file ../../raid/1078int.c" error may occur during rebuild (SCGCQ00856256) - Fixed an issue where no error message shown when there is a failure to disable SSD caching of an offline VD (SCGCQ00905310) - Fixed an issue where "1 JBOD(s) found on the host adapter" may appear in legacy OpROM post even though no JBODs are present (SCGCQ00882729) - Fixed an issue where firmware may halt with "line 245 in file ../../raid/1078int.c" in log under stress with maximum VDs and background operations (SCGCQ00890133) - Fixed an issue where the HII may report a different Battery/SuperCap status than MSM/StorCLI would (SCGCQ00879726) - Fixed an issue where the firmware may hang due to an "Illegal Instruction Exception" error (SCGCQ00850441) - Fixed an issue with less-than-expected performance of Write-Verify SCSI commands in RAID0 (SCGCQ00866261)
Enhancements: - Added more descriptive port information to include link width in PHYs (SCGCQ00854621)
Version 24.7.0-0056 - Moderate Impact/Low Probability of Occurrence ------------------- Fixes: - Fixed issue where UNMAP or TRIM commands might fail on SSD in JBOD Mode (SCGCQ00853147) (RETAIN Tip H214381) - Fixed an issue where an iMR RAID configuration may fail to import to 12gbps MR (SCGCQ00833765)
Version 24.7.0-0052 - High Impact/High Probability of Occurrence ------------------- Fixes: Incorporated MegaRAID FW stack 6.6 Fixed an issue where a drive reporting itself as 0MB shows up as Unconfigured Good (SCGCQ00784319) Fixed an issue where the firmware might hang during error handling of sense code 0b/47/xx (SCGCQ00701744) Fixed an issue where some SSDs may cause the system to hang at POST (SCGCQ00595506) Fixed an issue where an iMR RAID config may fail to import to 12gbps MR (SCGCQ00833765) Fixed an issue where R0, R5 and R6 read bandwidth dropped abruptly at 256K block size with 24drive SATA SSD config (SCGCQ00609808) Fixed an issue where RAID10 performance is under-performing (SCGCQ00794773) Fixed an issue where in some cases the LSI chip would convert an incoming chip reset to a system reset (SCGCQ00664261) Fixed an issue where many pRdm/pRequest/pReply messages would appear in LSI firmware log (SCGCQ00752195) Fixed an issue where when a consistency check is aborted, the adapter may reset (SCGCQ00819811) Fixed an issue where Patrol read does not start and gives incorrect warning message (SCGCQ00728404) Fixed an issue where the controller may reset unexpectedly during error handling (SCGCQ00825126) Fixed an issue where StorCLI may report Enclosure Not Found (SCGCQ00843146) Fixed an issue where x880 nodes may report excessive 'SCL STUCK Low! While I2C Rx Receiving Data' in LSI firmware log (SCGCQ00728935) (Retain TIP H213891) Fixed an issue where the command timeout for FED (SED) drives is too short, resulting in 05/2C codes (SCGCQ00797355) Fixed an issue where bandwidth falls as queue depth increases on R5/R6 24/40 drive SAS HDD configs at 256k block size (SCGCQ00701768) Fixed an issue where some drives may get bad PI CRC even though data is correct resulting in drive failure (SCGCQ00819314) Fixed an issue where the firmware may exposed more than 240VDs to host even if host driver doesn't support that many (SCGCQ00829214) Fixed an issue where MSM may display an error message if 'Schedule Consistency Check' is selected (SCGCQ00832908) Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives, preventing data issues (SCGCQ00838953) (Retain TIP H214323) Fixed an issue where the MegaRAID POST may display "The native configuration is not supported by current firmware" (SCGCQ00812842) Fixed an issue where the EFI Driver Health Protocol will show Fail when more than 64VDs are configured (SCGCQ00830918) Fixed an issue where OS may BSOD when upgrading firmware on a controller the OS has booted from if Online Controller Reset is performed (SCGCQ00825725) Fixed an issue where controller wouldn't go to halt state after multibit ECC errors detected (SCGCQ00783186) Fixed an issue where Opal-compliant FDE (SED) drives were being marked as FDE/SED when they shouldn't be (SCGCQ00788250) Fixed an issue where correctable ECC error interrupts were being masked (SCGCQ00814997) Fixed an issue where reconstructed VDs were not being reflected in MSM until system reboot (SCGCQ00839018) Fixed an issue where controller commands may fail when an LD is deleted during reconstruction (SCGCQ00821693) Fixed an issue where firmware would go to MonTask when making VDs offline while a Rebuild is occurring under IO (SCGCQ00825775) Fixed an issue where commands to FDE (SED) drives may not respond within 500ms (SCGCQ00844445) Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00844447) Fixed an issue where HDD/SSD microcode updates may report fail even though they succeeded (SCGCQ00553252) Fixed an issue where slot numbers may be wrong systems with 32 drive slots (SCGCQ00529592)
Features and Enhancements Improved Jetstress / Exchange latencies (SCGCQ00717161) Added support for Learn Cycle debug commands in firmware (SCGCQ00814991) Added ability to clear the MaintainPdFailHistory (SCGCQ00474559) Improved drive rebuild performance (SCGCQ00427581) Improved Cache Offload error handling on read from the flash interface (SCGCQ00524419) Improved average latency and max latency in Windows operating systems (SCGCQ00671670) Implemented power throttling (SCGCQ00457280) Improved load balancing on >2 drive R1 VD of SSDs (SCGCQ00593588) Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490822) Added support for communicating with multiple controllers over I2C (SCGCQ00485924) Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00651680) Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00399739) Improved accuracy of ROC temperature display (SCGCQ00575037) Increased range of priorities for background tasks, CC/PR/Rebuild/Migrate/BGI (SCGCQ00313882) Added support for 512e drives (SCGCQ00619363) Prevented a situation where there may be excessive overtemp warnings in the firmware log (SCGCQ00820067) Improved DDR3 signalling margin during heavy I/O workloads (SCGCQ00824711)
Version 24.2.1-0052 - Non-Critical ------------------- Enhancement(s): - Added a special handling for interactive password. - Implemented mechanism to allow system BIOS to put entries for iMR memory allocation into proper table. Fixes: - - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key.resent. - Fixed an issue where foreign configurations fails to import maximum number of configurations. - Fixed simpleswap port mapping. - Fixed an issue where 'Cli show all' command fails with error msg 'Error! App exec failed in FW PCLIError! Internal.' - Fixed an issue where ‘Cli show all’ command fails with error message ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an issue where Coherency bit was not enabled in SRAM TLBs.
Version 24.2.1-0045 - Non-Critical ------------------- Fixes: - Fixed an issue where cache offload failured with pinned cache on R5 VD. - Fixed an issue where using upper case characters in command 'cli set securitykey' fails with error code '1001' and error message 'invalid key.' - Fixed an issue where system would not boot into legacy mode. - Fixed an issue where default setting of VD doesn't reflect MFC's setting. - Fixed an issue where ‘Cli show all’ command fails with error msg ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an where ServeRAID M5210 showed the wrong slot numbers in both MR and iMR, in both HII and MSM.
Version 24.2.1-0027 - Non-Critical ------------------- Enhancment(s): - Added support for ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade for IBM System x (47C8668) - Added event in firmware to indicate that an INIT operation was halted due to reboot or other failure Fixes: - Increase backplane support to 32 slots. - Enable 512E support. - Fixed an issue where system is not allocating memory correctly when MR and iMR are in the same configuration - Fixed an issue where the user is Unable to create a RAID10 through Ctrl R using 4k drives. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled. - Fixed an issue where switching between external key management (EKM) and Local Key Management (LKM) without rebooting results in the current secret key string becoming invalid/null. - Fixed an issue where cache memory size is listed as zero in controller Information. - Fixed an issue where re-keying a controller with External key management (EKM) enabled and rebooting the system results in a corrupted key ID and an error message "Unable to communicate with EKMS ..." is displayed. - Fixed an issue where performing an online firmware update or online controller reset (OCR) on a controller with External key management (EKM) enabled, results in all secured drives marked as foreign. - Fixed an issue where CacheCade volumes, which are not supported, could be created using 4K SSD's. - Fixed an issue where removing the last physical drive of arrays could result in a firmware fault. - Fixed an issue where MegaRAID Storage Manager does not show an option to create virtual drives when the first drive in the array is missing in a partial virtual drive where all drives are configured. - Fixed an issue where switching the security mode from external key management (EKM) to local key management (LKM) on iMR controller will result in a corrupted controller key. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect.
Version 24.0.2-0013 ------------------- -Initial release ibm_fw_sraidmr_5200-24_12_0-0039_linux_32-64_chg
ServeRAID M1000 Series SAS/SATA Controller Firmware Update
Adapters Supported: ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
Version 20.13.1-0254 --------------------
Version 20.13.1-0252 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: Fixed issue where wrong drive connector information (connector: null x0) shows in MSM (SCGCQ00996578) Fixed issue where firmware hit assertion while booting with 4K PDs. (SCGCQ00944388) Fixed system hangs that could occur due to recoverable errors being marked as unrecoverable (SCGCQ00923692) Fixed issue where exception would occur during foreign import while importing number of VDs greater than supported count (SCGCQ00931011)
Version 20.13.1-0245 - Moderate Impact/Low Probability of Occurrence --------------------- - Fixed an issue where virtual drivers become inconsistent after the system an AC failure. (SCGCQ00897229) - Fixed an issue where Illegal request sense messages are seen repeatedly in FW logs due to attempts to collect temperaure for pds which does not support page (0x2F) at every smart poll interval. (SCGCQ00898459) - Fixed an issue where command "cli set securitykey=Lsi@12345" fails with error code "1001" and error message "invalid key". - Added a warning message when preboot configuration utility is Disabled but the user tries to launch it. (SCGCQ00662761) - Fixed an issue where WebBIOS Advance software option menu from main page could hang the system. (SCGCQ00683327) - Updated the drive speed display string to support 12Gb/s (SCGCQ00751036) - Corrected inconsistency in size showing in for total capacity property between webBIOS and MSM (SCGCQ00752176)
Version 20.13.1-0200 - Critical ------------------- Enhancement: - Display drive speed for 12 GB Seagate hard drives in MSM. - List battery status in BIOS as N/A for iMR controllers Fixes: - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where WebBIOS advanced software option locks the server. - Changed patrol read completion time calculation to include time for associated IO operations. - Fixed SGPIOs signal issue.
Version 20.11.1-0184 - Suggested ------------------- Fixes: - Updated SBR to avoid an errata that could cause correctable CPU errors on some systems. - Fixed an issue where NULL events may show in event log, preventing capture of controller event logs.
Version 20.11.1-0137 - Suggested ------------------- Enhancement(s): - Update recovery mode page (WriteRetryCount and recoveryTimeLimit) during discovery of a drive and during spinup recovery when sense 6/29 is received.
Fixes: - Fixed an issue where certain drives were reporting a temperature of 65 degrees Celsius. - Fixed an issue where systems with SSD HDD will pop up an error message after creating a virtual drive via HII on M1115. - Fixed an issue where the drive state is not modified when a recon virtual drive is created from the reboot path.
Version 20.10.1-0107 - Suggested ------------------- Fixes: - Fixed grammatical errors in WebBIOS. - Fixed an issue in WebBIOS Drive Group Definition screen where enclosures should not be selectable in the Drives column. - Fixed an issue in uEFI-WebBIOS where the white bars do not match up under VD properties page. - Fixed an HII browser issue where a drive performing a copyback displayed the state as "Replacing" but other utilities showed the state as copyback. - Fixed an HII browser display issue where SATA drives showed "0" for the value of RPM under drive properties. - Fixed a display issue where the HDD port number showed incorrectly in an HII browser. - Fixed an HII browser issues where creating a global hotspare gave the user an error message. - Fixed an HII browser issue when security is changed with local key management the changing security report current mode is disabled as external keu management. - Fixed an HII browser issue where the user got the following error message, "The request command has invalid arguments," when changing the security key report. - Fixed an HII browser issue where the user was unable to save the configuration after adding an extra span during array creation. - Fixed an HII browser issue where the return value was not correct when the browser called extract config with a result of null.
Version 20.10.1-0101 - Suggested ------------------- Fixes: - Fixed an issue where a system uefi error will occur when the bootTargetId is set to 0. - Fixed a problem where the firmware will allocate the sata bbl entry for the drive when moved from unsupported to supported. - Fixed a firmware issue where the TargetId for the recon LD should be set to its original LD. - Fixed a HII error message "Question Value mismatch with Option value!" after selecting factory defaults in HII. - Fixed an issue where the firmware fails to create the configuration and utilities fail to report the VD size after the reconstruction.
Version 20.10.1-0091-01 - Non-Critical ------------------- Fix - Fixed issue where update may fail to find all supported controllers in SLES 11 SP 2. Note not change in the firmware; it is the same as package 20.10.1-0091.
Version 20.10.1-0091 - Suggested ------------------- Enhancement: - Add support for ServeRAID M1115
Fixes: - Fixed issue where after starting a reconstruction on a RAID 0 the progress %, does not increase. - Fixed an issue where a new drive, inserted after a drive failure, goes to JBOD and not auto rebuild. - Fixed physical drive count issue that stated more than (16) devices already exists
Version 20.10.1-0069- Suggested ------------------- Enhancement: - ServeRAID M1015 Dimmer Switches are disabled by default.
Fixes: - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Fixed issue where WebBIOS gives garbled message when enabing FDE on an existing Disk Group - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed a problem where firmware was taking to long to complete the PCI config read. Causing the system to generate an NMI. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed an intermittent RAID key failure during power-on.
Version 20.10.1-0052- Critical ------------------- Enhancement: - Add support to pass SMART errors for JBOD drives to MSM
Fixes: - Added check to return SCSI sense Check condition if PMI is set and LBA is non zero for SCSI Read Cap 16. - Fixed issue where a bluescreen occurs handling RAID 1 with HSP and medium errors. The bluescreen occurs becausethe driver timesout while fw is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early
Version 20.10.1-0045 - Critical ------------------- Fix: - Fixed issue where firmware has incomplete writes during power fail and recovery
Version 20.10.1-0036 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users to downlevel firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur
Version 20.10.1-0022 - Critical ------------------- - Fixed issue where Windows 2008 R2 WS08 cannot be installed properly on ServeRAID M1015 SATA JBOD with a uEFI boot. - Added warning message when user tried to change more then 16 drives to JBOD. - Addressed a problem where direct attached drives are given incorrect slot numbers - Added fixes from LSI channel products. - Fixed issue where a single JBOD drive will not boot after a Windows 2008 R2 installation.
Version 20.5.1-0014 - Critical ------------------- - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed problem where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 20.1.1-0059 - Critical ------------------- Fixes: - Fixed an issue where a physical drive that is changed to JBOD from powersave will become unconfigured good again - Addresses an issue where data becomes inaccessible when a drive is secured after data has been written
Version 20.1.1-0049 - Suggested ------------------- Enhancement - Support M1000 key for RAID 5 and SED support
Fixes: - Fixed an issue in M3950M3 where webbios would hang - Fixed an issue where the controller properties in WebBIOS such as Rebuild, CC and BGI are not changing when we use up and down arrow keys. - Fixed an issue where Enclosure ID's are not being shown in MSM
Version 20.1.1-0046 - Suggested ------------------- - Enabled support for the ServeRAID M1000 Series Advanced Feature Key.
Note: All Logical Drives must previously have the encryption enabled before data is written on to the SED drives. Please read Retain TIP H123152 for more details.
Version 20.1.1-0042 ------------------- - Initial release ibm_fw_sraidmr_1000-20_13_1-0254_linux_32-64_chg
Broadcom NetXtreme I Firmware Update Utility for IBM servers and options using the Broadcom NetXtreme I ethernet adapters.
Version 17.4.4.2a, March 08, 2016
This update package supports the following Broadcom devices: =========================================================== - BCM5717 NetXtreme I LOM - BCM5718 NetXtreme I LOM - BRCM5718 NetXtreme I Gigabit Ethernet Adapter / Product No: 49Y7900 - BCM5719 NetXtreme I LOM - BCM5719 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9352 - BCM5720 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9370
This update packages updates your Broadcom LOM/Adapter Firmware Code to the levels shown below:
Firmware code: Version Previous ==================== ======== ========== Bootcode for 5717 1.65 1.65 Bootcode for 5717C0 2.10 2.10 Bootcode for 5718 1.65 1.65 Bootcode for 5719 1.43 1.43 Bootcode for 5720 1.39 1.39 iSCSI Boot 18.0.0 18.0.0 EFI Undi 17.4.0* 17.4.0* PXE NX1 17.2.1 17.2.1 NCSI Firmware NX1 1.3.12 1.3.12
Note: An asterisk (*) following a version number represents a certified driver. Arrows (<<) between versions indicate the component has been updated from the previous released software kit.
brcm_fw_nic_17_4_4_2a_linux_32-64_chg
BIOS/FW/UEFI Update for IBM N2200 Series SAS/SATA HBA Controllers
Controller Supported: IBM N2215 SAS/SATA HBA for IBM System x (47C8676) IBM N2225 SAS/SATA HBA for IBM System x (00AE912) IBM N2226 SAS/SATA HBA for IBM System x (00AE916)
Version 1.09.04 - Moderate Impact/Low Probability of Occurrence --------------- Contains: BIOS Firmware UEFI Driver 08.21.06.00 09.00.02.00 10.00.00.00
Fixes: - Fixed issue where HDD removal not properly reported as Target Device missing when attached to adapter through an expander. (SCGCQ00777858) - Fixed issue where Fault State (0x265d) is observed in driver logs while connecting an enclosure with fully populated SATA drives (SCGCQ00856085) - Fixed issue where 0x7C54 fault seen during I/T switching (SCGCQ00847013) - Fixed issue where certain drive pull scenarios result in longer time to discovery running (~3+ seconds) (SCGCQ00843759) - Improved PCIe Config operation handling to avoid 0x0D03 faults (SCGCQ00836878) - Fixed issue where controller could fault with 0x4A00 during link break (SCGCQ00793956) - Fixed the occurrence of fault 0x1708, when a free MID is attempted to be failed to the host. (SCGCQ00826420) - Fixed occurrence of fault 0x5814/0x5813 while handling Task Management during IO Timeout (SCGCQ00865024) - Fixed issue where SATA drive with slow spin up can cause IO timeout in Linux. (SCGCQ00869554) - Fixed system hang after adapter reset with heavy IO load (SCGCQ00877099) - Fixed issue with slow BIOS interface response with certain hardware e nvironments (SCGCQ00888867) - Fixed UEFI issue where in an environment with multi-lun devices where lun size varies, backup GPT corruption can occur (SCGCQ00907441)
Enhancements: - In BIOS added a new field to Device Properties called "Logical Sector Size". The possible values are 512B, 4K and Unknown. (SCGCQ00887338) - Improved the response time in UEFI HII utility for SAS3 IT/IR Controllers (SCGCQ00821793)
Version 1.07 - Moderate Impact/Low Probability of Occurrence --------------- Contains: BIOS Firmware UEFI Driver 08.15.01.00 07.00.01.00 08.00.00.00 Firmware:
Fixes: - Fixed issue where 0xD025 fault appeared while running non-FastPath I/O to SATA disk with outstanding FastPath I/Os to SAS disk (SCGCQ00604668) - Fixed fault 0xD071 while running stress and glitching all 4 phys as part of a cable break test. (SCGCQ00590502) - Fixed MPI Power Management Global Request Change to Reduced or Standby state results in "Operation State Not Supported" or "IOC Busy" (SCGCQ00584284) - Fixed issue where when transitioning MPI Power Management speed from lower to higher rate the command falsely reported as successful (SCGCQ00584288) - Fixed issue with mixture of FastPath IO's and standard firmware path IO's timing out on SATA disks (SCGCQ00576190) - Fixed SATA only issue where Multiple 'Write Verify' SCSI commands with zero data length leads to f/w fault (0x4203 or 0x4C31). (SCGCQ00549293) - Fixed fault 0x6230 while disabling expander phys and running stress in multi-path failover environment (SCGCQ00692652) (SCGCQ00699059) - Fixed various conditions causing 0x6230 fault when cable breaking (SCGCQ00669775) (SCGCQ00699057) (SCGCQ00643835) - Fixed issue where rapid successive controller resets would cause HBA to stop responding on the PCIe bus (SCGCQ00556766) - Fixed issue where when phy power management is enabled, TARGET RESET function fails yet command is reported a success. (SCGCQ00570820) - Fixed issue where PCIe Link Down can cause transmit margin field to not reset resulting in PCIe validation tests failing (SCGCQ00663185) - Fixed issue where SCSI command is not failed with expected response when SATA drive undergoing a format operation and reserved fields are set as Non-Zero value (SCGCQ00679566) - Fixed issue where read log ext command wasn't issued by PL FW to recover from error during the failure of write verify command (SCGCQ00675166) - Fixed IOC fault state 0x1609 caused by Message Unit Reset (SCGCQ00582515) - Fixed issue where SAS Phy page 1 and 2 error counters wrap around when maximum values are reached. (SCGCQ00651231) - Fixed fault 0x265D when running large block IO with higher Qdepth (SCGCQ00600832) - Fixed issue in Transport Layer Retries Code causing 0x265D and 0x0501 faults (SCGCQ00609576) - Fixed issue where Bad TLB entry causes 0x26B5 fault in IT/IR firmware (SCGCQ00629210) - Fixed 0x6828 fault when using large CDB (SCGCQ00614498) - Fixed fault 0x1901 seen when running Unmap IO’s during task aborts for a SATA drive (SCGCQ00711858) - Fixed issue where system gets hung & reboot while running IO's along with diag reset on the Controller which has Active and Inactive volumes. (SCGCQ00714125) - Fixed issue where cards would fault with 58B4 on power up due to incorrect SERDES setting (SCGCQ00728903) - Fixed WRITE SAME(10) and WRITE SAME(16) SCSI commands fail on last LBA of SATA Drive, incorrectly reporting logical block out of range. (SCGCQ00703433) - Fixed fault 0x4203 when WRITE AND VERIFY (16) command us executed to SATA Drive for LBA Out of Range (SCGCQ00705320) - Fixed issue where ATA Translation of sector count in sense data is inconsistent for READ DMA pass-through cmd (SCGCQ00712688) - Fixed issue where CLI command to dump L1 data cache causes 0x265D fault (SCGCQ00715317) - Fixed SATA Init problem causing 0x6230 controller fault (SCGCQ00683795) - Fixed fault 0x265D hit when booting controller with attached enclosure (SCGCQ00709712) - Fixed issue where Negotiated Physical Link Rate in SAS IO Unit Page 0 may not be correct after pulling a cable (SCGCQ00696408) - Fixed issue in NVDATA where SGPIO PHYs reversed (SCGCQ00750746) - Fixed I2C slave status interrupt not always cleared with I2C Write operation (SCGCQ00731646)
Enhancements: - Improved implementation of SCSI transport layer (SATL) handling while the SATA drive is in security 'frozen' state (SCGCQ00549302) - SCSI Transport Layer: Indicate support for the ATA Device Server Password security protocol (SCGCQ00625580) - IO Processor Target Mode performance improvements (SCGCQ00685827)
UEFI:
Fixes: - Fixed issue where the navigation of HII screens was very slow when no drives are connected to an expander (SCGCQ00569123) - Reduce the boot time for UEFI driver for large configurations (SCGCQ00498101) (RETAIN Tip H212119) - Fixed issue where HII configuration utility did not print the complete SAS address (SCGCQ00709781) - Fixed issue where View Physical Disk Properties screen on HII was not showing correct disk details (connector:encl:slot) when more than 8 disks are directly attached. (SCGCQ00691104)
Enhancements: - Obtain the Physical Slot number from the PCI Bridge first and use fall back to SMBIOS table if unable retrieve slot number from PCI Bridge. (SCGCQ00498095) - Retry Test Unit Ready command if drive foes not respond on first try. (SCGCQ00518198) - Adding a small delay (2 seconds) to get proper operation status after starting an operation (like consistency check) in HII (SCGCQ00621480) - Enhanced HII configuration utility to display tape drive information (SCGCQ00700835)
BIOS:
Fixes: - Fixed issue where the system boot hangs when Legacy BIOS is disabled (using HII) on certain UEFI systems. (SCGCQ00637088) - Fixed issue where the Legacy BIOS failed to detect certain large capacity SAS drives (SCGCQ00696486)
Enhancements: - Support configurable timeout for Start Stop Unit Command. (SCGCQ00694336)
Ehhanncements: - Add support for N2225 and N2226 SAS/SATA HBA Controllers Fixes: - Fixed an issue where SAS SSDs may not show up in the uEFI configuration Utility (HII)
Adapters Systems: IBM Flex System x240 M5 Compute Node
IBM Flex System x880 X6 Compute Node
ServeRAID M1215 SAS\SATA Controller for IBM System x (46C9115)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 24.12.0-0038
--------------------
Version 24.12.0-0034
--------------------
Version 24.12.0-0033
--------------------
Version 24.12.0-0028
--------------------
Version 24.12.0-0027
--------------------
Version 24.12.0-0024 - High Impact/High Probability of Occurrence
--------------------
FW Package: 24.12.0-0024
HII: E3.19.07.03
UEFI Driver: 0x06130200
BIOS: 6.30.03.0
MR FW: 4.620.00.6070
iMR FW: 4.620.01.6071
Fixes:
- Fixed the potential of a data miscompare that was observed only at a vendor test facility under very heavy I/O and abnormal practices (SCGCQ00990093, Port of SCGCQ00976904)
- Fixed an issue where performing back-to-back target resets on the same JBOD may results in an Controller Reset (SCGCQ00857181)
- Fixed an issue where firmware may allow a Reconstruction to be performed when Pinned Cache is present (SCGCQ00857692)
- Fixed an issue where "MonTask" error may occur when importing a Foreign Configuration (SCGCQ00860066)
- Fixed an issue where controller does not Stop on Error and boots into Operating System when Pinned Cache is present(SCGCQ00860503)
- Fixed an issue where firmware allows CacheCade Virtual Drive deletion when Pinned Cache is present (SCGCQ00871973)
- Fixed an issue where a firmware downgrade FW downgrade may fail when IO and Background Operations are being performed (SCGCQ00873239)
- Fixed an issue where error "Core 0 exception in line 245 in ../../raid/1078int.c" may occur when Target Reset sent to Physical Disks in parallele with Background Operations (SCGCQ00878554)
- Fixed an issue where error "Assertion failure in ../../dm/src/dmDrvPrep.c at line 836" may occur (SCGCQ00879198)
- Fixed an issue where firmware may hang on Task Abort (SCGCQ00881901)
- Fixed an issue where iPtr and rPtr values may be greater than the size of the buffer (SCGCQ00886685)
- Fixed an issue where more IOs were allowed than the available buffer could support (SCGCQ00894472)
- Fixed an issue where the Operating System may become unresponsive after creating multiple sliced Virtual Disks (SCGCQ00894608)
- Fixed an issue where adapter may reset under certain conditions (SCGCQ00895554)
- Fixed an issue where error "line 1271 in file ../../raid/1078dma.c" may occur when running FastPath with CacheCade (SCGCQ00898799)
- Fixed an issue where forceCacheFlush was occurring in an iMR context where it doesn't apply (SCGCQ00899762)
- Fixed an issue where importing 240 Virtual Drives may cause a firmware fault (SCGCQ00900601)
- Fixed an issue where error "line 229 in file ../../raid/mtask.c" may occur when Hibernating Windows 10 (SCGCQ00905864)
- Fixed an issue where importing a Foreign Configuration may fail (SCGCQ00908325)
- Fixed an issue where FastPath IO may not time out properly (SCGCQ00910124)
- Fixed an issue where StorCLI may report an incorrect ScapBatVersionNO when using command "/c0/cv show all" (SCGCQ00914343)
- Fixed an issue where some default values may not be picked up for unchanged controller properties sharing the same byte (SCGCQ00914740)
- Fixed an issue where chain mid allocation for JBOD may fail (SCGCQ00915081)
- Fixed an issue where configuration creation may fail after creation of a CacheCade Virtual Drive followed by JBOD creation (SCGCQ00917307)
- Fixed an issue where a cable pull during a Target Reset on JBOD may result in a data TLB error (SCGCQ00923289)
- Fixed an issue where controller may become unresponsive after hitting an OCM error(SCGCQ00924986)
- Fixed an issue where the Physical Device map was being updated unnecessarily (SCGCQ00927173)
- Fixed an issue where some drives could not be discovered successfully (SCGCQ00927792)
- Fixed an issue where attempting to stop a Drive Erase operation from application may cause firmware to hang (SCGCQ00928150)
- Fixed an issue where controller disappears when performing a cable pull (SCGCQ00928333)
- Fixed an issue where CacheCade Virtual Drive creation may fail with false error (SCGCQ00930044)
- Fixed an issue where controller may hang when importing a drive into a RAID0 CacheCade Virtual Drive (SCGCQ00934196)
- Fixed an issue where firmware would not allow an Online Firmware Update (SCGCQ00936693)
- Fixed an issue where error "line 219 in file ../../raid/mficmd.c" may occur when powering system on from S3 sleep (SCGCQ00937487)
- Fixed an issue where error "MonTask: line 1281 in file /raid/1078dma.c" may occur when running enclosure cable pulls with CacheCade Virtual Drive (SCGCQ00941531)
- Fixed an issue where firmware recovers invalid cache after firmware update (SCGCQ00944012)
- Fixed an issue where LdInitPdDone did not include flush command block (SCGCQ00945033)
- Fixed an issue where driver may panic and controller may reset on medium errors with Pinned Cache (SCGCQ00948257)
- Fixed an issue where Virtual Drives don't revert back to Write-Back once the controller Pinned Cache is destaged (SCGCQ00948466)
- Fixed an issue where firmware may fault when running full initialization on Virtual Drives with LDBBM entries created during Consistency Check (SCGCQ00952627)
- Fixed an issue where a SES Discovery Error may occur on repeated retries for some expanders (SCGCQ00976741)
- Fixed an issue where the drive bay LED may not turn off when the drive is removed (SCGCQ01003387)
- Fixed an issue where error "MonTask: line 4946 in file ../../raid/ld.c" may occur when multipath cable pull occurs Patrol Read (SCGCQ00857528)
- Fixed an issue where Locate LED turns off when cable failover performed (SCGCQ00869681)
- Fixed an issue where "Watchdog Timer Exception" error followed by firmware fault after initiating Physical Drive erase operation (SCGCQ00872140)
- Fixed an issue where a firmware fault occurs when issuing Task Management commands on 240 JBODs while running IO (SCGCQ00872889)
- Fixed an issue where Virtual Drive deletion could cause IO freeze time to increase (SCGCQ00873201)
- Fixed an issue where a data TLB error would occur after issuing task abort (SCGCQ00873991)
- Fixed an issue where "MonTask" error may occur due to a Full-Disk Encryption / Self-Encrypting Disk that fails to spinup (SCGCQ00874332)
- Fixed an issue where error "adapter at baseport not responding" may occur (SCGCQ00880919)
- Fixed an issue where cache is not flushed immediately upon firmware recieving the cache-flush out-of-band command (SCGCQ00882125)
- Fixed an issue where IO may slow while deleting Virtual Drives (SCGCQ00891924)
- Fixed an issue where IO halts on JBODs with "read/write error" when the target drives are reset in Linux (SCGCQ00893588)
- Fixed an issue where "MonTask: line 1413 in file ../../raid/config.c" may occur when creating a CacheCade Virtual Drive (SCGCQ00894610)
- Fixed an issue where firmware does not log controller property change event for enabling/disabling 240VD feature (SCGCQ00895577)
- Fixed an issue where event length may come up as 0 (SCGCQ00897406)
- Fixed an issue where firmware was not seding the proper status for aborted commands (SCGCQ00900250)
- Fixed an issue where controller firmware may fault during Hibernation or when the driver loads twice (SCGCQ00902938)
- Fixed an issue where firmware may fault after creating 240 Virtual Drives and rebooting the server (SCGCQ00905416)
- Fixed an issue where progress for CacheCade disassociation activity is not displayed for all source Virtual Drives (SCGCQ00906846)
- Fixed an issue where error "Assert at line 1181 mpthostcmd.c" may occur when FastPath has been disabled or for a timeout IO (SCGCQ00910006)
- Fixed an issue where error "LMID HS-FIFO Error 0x8" may occur when removing a redundant path to a JBOD with IO (SCGCQ00914274)
- Fixed an issue where applications may show incorrect value for Max Parallel Commands field of Controller Information in iMR(SCGCQ00914751)
- Fixed an issue where firmware was failing ABORT TASK and ABORT TASK SET commands on SATA JBOD (SCGCQ00915088)
- Fixed an issue where exception may occur on Online Controller Reset (SCGCQ00917523)
- Fixed an issue where "MonTask" error may occur in a drive removal or multipath removal scenario (SCGCQ00919229)
- Fixed an issue where the wrong MFI_STAT is returned from PdDcmdSysPdMapAbort (SCGCQ00930593)
- Fixed an issue where an Online Firmware Update may fail when downgrading from firmware that supports 240 Virtual Drives to firmware that does not (SCGCQ00930917)
- Fixed an issue where "DM_EnableFastPathOnDevice :: FP enabled on devhandle" may be printed in logs even though FastPath is enabled (SCGCQ00936617)
- Fixed an issue where "C0:Index 0098 allocated from pool 3" prints continuously in log with 12Gbps Enclosures and SATA drives (SCGCQ00937572)
- Fixed an issue where firmware prematurely rejects ONFI flash module (SCGCQ00937617)
- Fixed an issue where SafeID may change on repeated queries using StorCLI (SCGCQ00941577)
- Fixed an issue where firmware may fault when importing Virtual Drives with Pinned Cache (SCGCQ00949440)
- Fixed an issue where Write-Back Virtual Drives are converted to Write-Through on system reboot or Online Controller Reset(SCGCQ00859720)
- Fixed an issue where a Data TLB error may occur when firmware is upgraded or downgraded (SCGCQ00867065)
- Fixed an issue where a Data TLB error may occur when aborting a host command (SCGCQ00874357)
- Fixed an issue where firmware may fault when running IO with Task Resets on JBODs (SCGCQ00877673)
- Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur while running IO with 64 Virtual Drives and removing drives belonging to CacheCade (SCGCQ00878587)
- Fixed an issue where cache flush was occurring during Virtual Drive deletion (SCGCQ00878923)
- Fixed an issue where IO dip is seen when deleting Virtual Drives (SCGCQ00879193)
- Fixed an issue where a Data TLB error may occur when sending Target Reset on JBOD via out-of-band commands (SCGCQ00881919)
- Fixed an issue where perTunerMode is not set correctly after a controller reset (SCGCQ00882897)
- Fixed an issue where error "MonTask: line 2735 in file ../../ssd/ssd_cache_fw.c" may occur when error are injected repeatedly (SCGCQ00887019)
- Fixed an issue where a rebuild cannot be started for a degraded CacheCade Virtual Drive after heavy IO (SCGCQ00887428)
- Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur with IOs on maximum Virtual Drives configured and Background Opertations are occurring (SCGCQ00890133)
- Fixed an issue where Patrol Read doesn't resume after Consistency Check completes after a system reboot (SCGCQ00894344)
- Fixed an issue where StorCLI throws an error when performing "/c0/vx show all" after a Full Initialization on RAID1 Virtual Drive with SSDs (SCGCQ00904899)
- Fixed an issue where a firmware fault occurs when a copyback operation fails to start (SCGCQ00904905)
- Fixed an issue where LUID is changed when importing a non-240VD configuration to a 240VD firmware (SCGCQ00907658)
- Fixed an issue where a "MonTask" error may occur when under heavy JBOD IO and the JBOD IOs begin failing (SCGCQ00915078)
- Fixed an issue where error "line 1279 in file ../../raid/1078dma.c" may occur on iMR firmware during boot (SCGCQ00915092)
- Fixed an issue where controller reset occurs under stress with 240 Virtual Drives configured (SCGCQ00915398)
- Fixed an issue where Online Firmware Update would fail due to driver reload issues (SCGCQ00915454)
- Fixed an issue where a Data TLB error may occur during reconstrution operation when Target Resets are issued to JBODs (SCGCQ00921993)
- Fixed an issue where "Core 0 exception" is seen when trying to import Foreign Configurations with Pinned Cache (SCGCQ00863880)
- Fixed an issue where CTRL-R interface does not show correct port information when hotplugging enclosure paths (SCGCQ00866487)
- Fixed an issue where firmware may fault when an enclosure with an especially slow drive is present (SCGCQ00867120)
- Fixed an issue where error "MonTask: line 1280 in file ../../raid/1078dma.c" may occur on out-of-band command timeout (SCGCQ00872875)
- Fixed an issue where error "Assertion failure in ../../raid/cache.c at line 774" may occur after pulling out an enclosure cable (SCGCQ00878097)
- Fixed an issue where write performance drops in RAID5, Write-Through, No Read-Ahead, Stripe Size 64, 1MB IO at queue depth 128/256 (SCGCQ00878414)
- Fixed an issue where an imported 4K-drive RAID0 becomes Unconfigured Good on reboot (SCGCQ00895689)
- Fixed an issue where Online Firmware Update fails with "not supported" message (SCGCQ00915073)
- Fixed an issue where Logical Drive IO for FastPath-capable RAID0/RAID1 were not handled properly in the presence of a RAID5/RAID6 Write-Through volume running sequential write streams (SCGCQ00915409)
- Fixed an issue where a CRC mistmatch and Invalid Log Event are surfaced when checking Controller Properties in parallel with a Learn Cycle (SCGCQ00919945)
- Fixed an issue where performance drops are seen on writes to RAID1 FastPath volumes (SCGCQ00931895)
- Fixed an issue where event messages reporting CacheCade Virtual Disk target ID and remaining CacheCade size are incorrect (SCGCQ00864019)
- Fixed an issue where firmware faults when using an Online Controller Reset from StorCLI after having issued "supportResetNow" (SCGCQ00878150)
- Fixed an issue where an "Exception in Core -0" error may occur on iMR firmware under VMWare (SCGCQ00904103)
- Fixed an issue where "MsgAlloc: No free messages, poolIndex=4" may appear in logs while running IO on JBODs (SCGCQ00908982)
- Fixed an issue where the TTY log dump is not persistent across multiple boots (SCGCQ00877100)
- Fixed an issue where drives that return errors for all protocol commands may be retried indefinitely (SCGCQ00805369)
- Fixed an issue where setting the Learn Cycle property of iBBU09 gives an i2C error (SCGCQ00837206)
- Fixed an issue where driver may hang with LSI2008-based adapters (SCGCQ00843390)
- Fixed an issue where device wait queue is not cleared when drive is no longer online (SCGCQ00878401)
- Fixed an issue where Windows may BSOD on firmware upgrade when running driver 6.707.08.00 (SCGCQ00886272)
- Fixed an issue where disableImmediateIO NVDATA value is not honored by firmware (SCGCQ00886666)
- Fixed an issue where Foreign Configuration could be cleared even when Pinned Cache is present (SCGCQ00889209)
- Fixed an issue where a Virtual Drive under Reconstruction may go Degraded if the drive being reconstructed is removed before the operation completes (SCGCQ00891282)
- Fixed an issue where a "MonTask" error may occur after initiating a RAID Level Migration (SCGCQ00891288)
- Fixed an issue where system hang may occur after aborting running Consistency Checks repeatedly (SCGCQ00895265)
- Fixed an issue where a "MonTask" error may occur after creating 240 Virtual Drives and rebooting the server (SCGCQ00908121)
- Fixed an issue where LUID is changed when importing a non-240VD configuration to 240VD-enabled controller (SCGCQ00908153)
- Fixed an issue where a Virtual Drive may disappear on reboot if created with drives from a previously-deleted Virtual Drive (SCGCQ00914823)
- Fixed an issue where device wait queue is not cleared if a drive is no longer online (SCGCQ00923279)
- Fixed an issue where message "Found invalid event at fc4966ec" is printed in firmware log every 5 seconds (SCGCQ00931370, SCGCQ00979910)
- Fixed an issue where firmware is unable to detect all Virtual Drive's "Degraded" status for partial Virtual Drives created on the same Physical Drives (SCGCQ00942380)
- Fixed an issue where driver may panic and firmware may hang when medium errors are present (SCGCQ00954118)
- Fixed an issue where firmware does not discard dirty cache after firmware update (SCGCQ00992657)
- Fixed an issue where some Recoverable Errors were marked as Unrecoverable (SCGCQ01015699)
- Fixed an issue where HII and Ctrl-R show an incorrect message when trying to import a 65th Virtual Drive (SCGCQ00803718)
- Fixed an issue where Functional Level Reset (FLR) was not supported (SCGCQ00843936)
- Fixed an issue where Write-through and Write-back cache policies can be changed via Windows Logical Disk Properties. (SCGCQ00883311)
- Fixed an issue where many "LdDcmd ***** return pinned list 0" messages may be printed in firmware log (SCGCQ00895459)
- Fixed an issue where an alert is repeated twice for Cancel Consistency Check on Virtual Drives (SCGCQ00900027)
- Fixed an issue where error "Controller encountered fatal error and was reset" may occur under heavy IO and background operations (SCGCQ00905603)
- Fixed an issue where CacheCade-related 240 Virtual Drive checks were not checking controller properties (SCGCQ00905809)
- Fixed an issue where out-of-band applications may not display Show Configuration Summary when 240 Virtual Drives are created (SCGCQ00908237)
- Fixed an issue where a RAID0 using 4k drives may not be visible after reboot (SCGCQ00999181)
- Fixed an issue where firmware may not poll all temperature sensor channels every 5 seconds (SCGCQ00844152)
- Fixed an issue where Hard Drive RAID0 and RAID10 performance at 1M stripe size is suboptimal between queue depths of 16 to 256 (SCGCQ00876154)
- Fixed an issue where StorCLI will report Success when flashing an MR-only package on an iMR-only controller (SCGCQ00882149)
- Fixed an issue where 'Fw initializing devices' may hang with specific failed drives (SCGCQ00884719)
- Fixed an issue where controller may report cache size as "0" when no logical drives are present (SCGCQ00891273)
- Fixed an issue where a Physical Disk may not go to Online state even after creating a Virtual Drive on it (SCGCQ00910741)
- Fixed an issue where error "SAS core detected EEDP error in application tag" may occur (SCGCQ00936647)
- Fixed an issue where "storcli /c0 show all" shows many Bad Block messages in the log (SCGCQ00892136)
- Fixed an issue where firmware may log Controller Properties Changed events twice (SCGCQ00908238)
- Fixed an issue where a Virtual Drive under Reconstruction may be set Degraded if the drive under reconstruction is removed (SCGCQ00922677)
- Fixed an issue where firmware may enter fault state after system power cycle with an SSD drive (SCGCQ00835227)
- Fixed an issue where firmware may fault and RSOD may occur when a Virtual Drive is deleted when a Reconstruction is in progress on a PI-enabled VD combined with a slow initialization on another Virtual Drive (SCGCQ00872263)
- Fixed an issue where firmware doesn't report no SMART error when a Predictive-Failure Analysis (PFA) drive is present (SCGCQ00841772)
- Fixed an issue where firmware may not detect inserted drives (SCGCQ00876142)
Enhancements:
- Added support for restarting Patrol Reads after they are interrupted by a Consistency Check (SCGCQ00883176)
- Added ability to enable and disable 1M IO support via controller property (SCGCQ00893029)
- Added support for Task Management for JBOD/sysPDs (SCGCQ00855457)
- Reduced Command Block latency during Background Operations (SCGCQ00865372)
- Added ability to not moe Write-back Virtual Drives to Write-through when Pinned Cache is less than 50% of available buffers (SCGCQ00852502)
- Updated iMR queue depth to 928 (SCGCQ00888862, SCGCQ00930846, SCGCQ00896497)
- Disabled SATA HOQ support for iMR controllers (SCGCQ00942547)
- Added Task Management support for JBOD/sysPD (SCGCQ00861819, SCGCQ00855457)
- Re-enabled 1M IO support (SCGCQ00874200)
- Added support for Event Reporting for SuperCap Health after Learn Cycles (SCGCQ00894455)
ibm_fw_sraidmr_1200-24_12_0-0038_linux_32-64_chg
BIOS/FW/UEFI Update for IBM N2115 SAS/SATA Controller
Controller Supported: IBM N2115 SAS/SATA Controller (46C8989)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.20 - Non-Critical ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.02.00 7.27.04.00 Enhancements: - Added System X agentless support - Indicate support for the ATA Device Server Password security protocol - Allow UEFI and BIOS to be Enabled/Disabled individually - Added ConnectorName and EnclosureLevel fields to SAS Device Page 0 to help identify physical location of a target device - Set SATA HOLD threshold to be configurable in NVDATA - If HW can gets into a stuck state, clear that state upon break received.
Fixes: - Set SAS drives to track bad blocks using a bad block table rather than using a SCSI Write Long. - Fixed DMAGroup performance issue. - Fixed issue with Phase 18 IR FW boot a RAID volume (such as raid 10), 2308 bootup hangs at OROM "Initializing.." and fault 8803 seen. - Fixed report Luns command to a SATA drive fails with CheckCondition/Invalid Field in CDB when Allocation length set to Zero. - Fixed issue where Raid Accelerator IOs can hang if the stream of IOs suddenly stops. - Fixed issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed issue where lots of NCQ I/O error messages were reported. - Fixed issue where certain PCIe timeouts occur in the presence of link unavailable, and a hang condition or data corruption can occur. - Fixed issue where system hangs after adapter reset with heavy IO load. - Fixed issue where access to Last Logical Block Address (LBA) of SATA Drive is Prevented and LBA out Of range by one block is missed. - Made change to deal with link getting stuck and causing missing drives. - Fixed IR issue where page header information is not filled in when RAID PHYS DISK PAGE 0 is returned for a non-RAID Disk drive. - Fixed issue where controller hits 0x265d fault while creating volume when there is an inactive volume. - DID_SOFT_ERRORs are seen when hot plug is performed on the RAID1 volume along with IOs. - Fixed issue where system gets hung and reboots while running IO's along with diag reset on the Controller which has active and inactive volumes. - Fixed latency spikes seen during performance testing on OEM system - MPI 2.5: distribute target command buffers received across multiple reply queues. - Fixed issue where command sas2flash -dflash results in a non-functional system. - Fixed issue where internal device reset storm after controller reset using long CDB. - Fixed 0x6003 Fault Due to Task Management of Lost IO - Fixed 0x58A1 fault occurs on partner controller while issuing MUR to a target mode controller with outstanding IOs. - Fixed issue where IO error and stop when hot plug a HDD from RAID1 - Fixed issue where fault 8901 is seen once the volume is roamed.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
BIOS/FW/UEFI Update for IBM N2125 SAS/SATA Controller
Controller Supported: IBM N2125 SAS/SATA Controller (46C9011)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.20 - Non-Critical ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.02.00 7.27.04.00 Enhancements: - Added System X agentless support - Indicate support for the ATA Device Server Password security protocol - Allow UEFI and BIOS to be Enabled/Disabled individually - Added ConnectorName and EnclosureLevel fields to SAS Device Page 0 to help identify physical location of a target device - Set SATA HOLD threshold to be configurable in NVDATA - If HW can gets into a stuck state, clear that state upon break received.
Fixes: - Set SAS drives to track bad blocks using a bad block table rather than using a SCSI Write Long. - Fixed DMAGroup performance issue. - Fixed issue with Phase 18 IR FW boot a RAID volume (such as raid 10), 2308 bootup hangs at OROM "Initializing.." and fault 8803 seen. - Fixed report Luns command to a SATA drive fails with CheckCondition/Invalid Field in CDB when Allocation length set to Zero. - Fixed issue where Raid Accelerator IOs can hang if the stream of IOs suddenly stops. - Fixed issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed issue where lots of NCQ I/O error messages were reported. - Fixed issue where certain PCIe timeouts occur in the presence of link unavailable, and a hang condition or data corruption can occur. - Fixed issue where system hangs after adapter reset with heavy IO load. - Fixed issue where access to Last Logical Block Address (LBA) of SATA Drive is Prevented and LBA out Of range by one block is missed. - Made change to deal with link getting stuck and causing missing drives. - Fixed IR issue where page header information is not filled in when RAID PHYS DISK PAGE 0 is returned for a non-RAID Disk drive. - Fixed issue where controller hits 0x265d fault while creating volume when there is an inactive volume. - DID_SOFT_ERRORs are seen when hot plug is performed on the RAID1 volume along with IOs. - Fixed issue where system gets hung and reboots while running IO's along with diag reset on the Controller which has active and inactive volumes. - Fixed latency spikes seen during performance testing on OEM system - MPI 2.5: distribute target command buffers received across multiple reply queues. - Fixed issue where command sas2flash -dflash results in a non-functional system. - Fixed issue where internal device reset storm after controller reset using long CDB. - Fixed 0x6003 Fault Due to Task Management of Lost IO - Fixed 0x58A1 fault occurs on partner controller while issuing MUR to a target mode controller with outstanding IOs. - Fixed issue where IO error and stop when hot plug a HDD from RAID1 - Fixed issue where fault 8901 is seen once the volume is roamed.
Enhancement - Reduce the boot time for UEFI driver for large configurations Fixes: - Fixed an issue that caused the Integrated Management Module (iMM) in System x servers to report Warning: Sensor GPT Status has transitioned from normal to non-critical state. - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
Version 12.00.00.00 - Moderate Impact/Low Probability of Occurrence ------------------- Fixes: - Fixed potential protection fault due to sas device list corruption (SCGCQ00933587) - Fixed potential protection fault due to fw event list corruption (SCGCQ00933591) - Fixed memory leak occuring with failed firmware event data (SCGCQ00881682)
Enhancements: - Make use of additional HighPriorityCredit number of message frames for sending SCSI IO's (SCGCQ00899842) - Add support for configurable Chain Frame Size. (SCGCQ00933600, Port of SCGCQ00929253) - Added SLES11sp4 Support (SCGCQ00884793)
Version 10.00.02.00 -------------------
Version 8.00.00.00 - Moderate Impact/Low Probability of Occurrence ------------------ Fixes: - Driver initialization fails after some random iterations of load/unload of mpt3sas driver module (SCGCQ00589083) - Kernel Panic seen while booting the system with blank card. (SCGCQ00574258) - Driver initialization fails while performing HBA device hotplug/unplugs operations (SCGCQ00526796) - During driver load with a flaky disk in the setup, discovery related I/O times out which results in SCSI error recovery initiating host reset and then the controller won't see any disk (SCGCQ00571398) - During hot-plugging of a disk (having a flaky link) the disk addition stops and any further disk addition or removal doesn't happen on that controller. (SCGCQ00571402) - Drives attached to the expander are not discovered (SCGCQ00571418) - The driver message logs contain an entry "mpt2sas0: _base_get_ioc_facts: failed going to ready state (SCGCQ00571424) - device_unblock messages are not seen in the logs regarding device unblock (SCGCQ00664470) - Kernel panic while issuing LUN reset or target reset during running IOs (SCGCQ00655811) - Kernel Panic is seen when issued Diag reset from task management (SCGCQ00654562) - When IOC goes bad, while flushing the IOs, protection info SGLs are not released for DIF IOs. (SCGCQ00664893) - Synchronization between PF and VF host drivers is missing while performing diag reset operation and it leads to firmware faults such as 0x1500 (SCGCQ00682671) - When LUN 0 is offline, the other LUNs were not visible to the system. (SCGCQ00703194)
Enhancements: - Added code to display Location of End Device. (SCGCQ00452326) - On detecting that the IOC is over heated and entered fault state, the driver flush all running commands, and forces a panic with message ‘TEMPERATURE FAULT: STOPPING' (SCGCQ00654911) - Added new module parameter to allow /disallow host driver to issue SCSI commands to bring up drive. (SCGCQ00609923)
Version 4.00.01.00 - Non-Critical ------------------ Enchancement: - Add support for SLES 11 SP 3
Version 3.00.00.00 - Initial release ------------------ ibm_dd_mpt3sas_13_00_02_00_sles11_32-64_chg
 Broadcom NetXtreme TG3 Linux Driver
Version 3.137n
Copyright (c) 2015 Broadcom Corporation All rights reserved
tg3: Modify tg3_tso_bug() to handle multiple TX rings
tg3_tso_bug() was originally designed to handle only HW TX ring 0, Commit d3f6f3a1d818410c17445bce4f4caab52eb102f1 ("tg3: Prevent page allocation failure during TSO workaround") changed the driver logic to use tg3_tso_bug() for all HW TX rings that are enabled. This patch fixes the regression by modifying tg3_tso_bug() to handle multiple HW TX rings.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Signed-off-by: David S. Miller
Commit 506724c463fcd63477a5e404728a980b71f80bb7 "tg3: Override clock, link aware and link idle mode during NVRAM dump" changed the timeout value for nvram command execution from 100ms to 1ms. But the 1ms timeout value was only sufficient for nvram read operations but not write operations for most of the devices supported by tg3 driver. This patch sets the MAX to 50ms. Also it uses usleep_range instead of udelay.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Suggested-by: David Miller Signed-off-by: David S. Miller
tg3: Clear NETIF_F_TSO6 flag before doing software GSO
Commit d3f6f3a1d818410c17445bce4f4caab52eb102f1 ("tg3: Prevent page allocation failure during TSO workaround") modified driver logic to use tg3_tso_bug() for any TSO fragment that hits hardware bug conditions thus the patch increased the scope of work for tg3_tso_bug() to cover devices that support NETIF_F_TSO6 as well. Prior to the patch, tg3_tso_bug() would only be used on devices supporting NETIF_F_TSO.
A regression was introduced for IPv6 packets requiring the workaround. To properly perform GSO on SKBs with TCPV6 gso_type, we need to call skb_gso_segment() with NETIF_F_TSO6 feature flag cleared, or the function will return NULL and cause a kernel oops as tg3 is not handling a NULL return value. This patch fixes the problem.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 014b20133bcd442db554c2d2d86181b34cd15b66 commit 506724c463fcd63477a5e404728a980b71f80bb7 Author: Prashant Sreedharan Date: Sat May 24 01:32:09 2014 -0700
tg3: Override clock, link aware and link idle mode during NVRAM dump
When cable is not present the clock speed of some of the devices is reduced based upon power saving mode setting in NVRAM. Due to this NVRAM reads take long time to complete as a result CPU soft lockup message is seen. Fix is to override clock, disable link aware and link idle modes before NVRAM reads and restore them back after the reads are complete. During this period also check if the thread needs to be rescheduled and if there are any signals to handle.
Also decrease the NVRAM command execution timeout value to 1ms.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit de750e4c4bf36b8a14401527e6541e8620ea6267 Author: Michael Chan Date: Sun May 11 20:22:55 2014 -0700
tg3: Update copyright and version to 3.137
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit d3f6f3a1d818410c17445bce4f4caab52eb102f1 Author: Michael Chan Date: Sun May 11 20:22:54 2014 -0700
tg3: Prevent page allocation failure during TSO workaround
If any TSO fragment hits hardware bug conditions (e.g. 4G boundary), the driver will workaround by calling skb_copy() to copy to a linear SKB. Users have reported page allocation failures as the TSO packet can be up to 64K. Copying such a large packet is also very inefficient. We fix this by using existing tg3_tso_bug() to transmit the packet using GSO.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit d71c0dc4e961e74143a644f248fc1a39cabf6586 Author: Michael Chan Date: Sun May 11 20:22:53 2014 -0700
tg3: Don't modify ip header fields when doing GSO
tg3 uses GSO as workaround if the hardware cannot perform TSO on certain packets. We should not modify the ip header fields if we do GSO on the packet. It happens to work by accident because GSO recalculates the IP checksum and IP total length.
Also fix the tg3_start_xmit comment to reflect that this is the only xmit function for all devices.
Signed-off-by: Prashant Sreedharan Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Do not include vlan acceleration features in vlan_features
Including hardware acceleration features in vlan_features breaks stacked vlans (Q-in-Q) by marking the bottom vlan interface as capable of acceleration. This causes one of the tags to be lost and the packets are sent with a sing vlan header.
CC: Nithin Nayak Sujir CC: Michael Chan Signed-off-by: Vlad Yasevich Signed-off-by: David S. Miller
commit d7b95315cc7f441418845a165ee56df723941487 Author: Michael Chan Date: Fri Feb 28 15:05:10 2014 -0800
tg3: Don't check undefined error bits in RXBD
Redefine the RXD_ERR_MASK to include only relevant error bits. This fixes a customer reported issue of randomly dropping packets on the 5719.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Poll cpmu link state on APE + ASF enabled devices
On ASF enabled devices where the mgmt firmware runs on the application processing engine, there is a race between the tg3 driver processing a link change event and the ASF firmware clearing the link changed bit in the EMAC status register. This leads to link notifications to the driver sometimes getting lost.
Poll the CPMU link state as a backup for the normal interrupt path update if ASF is enabled.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Set the MAC clock to the fastest speed during boot code load
On the 5717, 5718 and 5719 devices, the bootcode runs slower when any port doesn't have a link due to clock speed slowing down as part of the link-aware feature. This leads to the driver timing out waiting for the bootcode signature.
This patch overrides the clock policy to the highest frequency just before reset and restores it after the bootcode is up.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit e565eec31d9d5b1024311564f6536162df951de4 Author: Michael Chan Date: Fri Jan 3 10:09:12 2014 -0800
tg3: Add unicast filtering support.
Up to 3 additional unicast addresses can be added to the perfect match filter table.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit f022ae62dd84425192b27100dcf907019f654d02 Author: Michael Chan Date: Fri Jan 3 10:09:11 2014 -0800
tg3: Refactor __tg3_set_mac_addr()
so that individual MAC address filter entries can be set.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
tg3: Expand 4g_overflow_test workaround to skb fragments of any size.
The current driver assumes that an skb fragment can only be upto jumbo size. Presumably this was a fast-path optimization. This assumption is no longer true as fragments can be upto 32k.
v2: Remove unnecessary parantheses per Eric Dumazet.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Initialize REG_BASE_ADDR at PCI config offset 120 to 0
The new tg3 driver leaves REG_BASE_ADDR (PCI config offset 120) uninitialized. From power on reset this register may have garbage in it. The Register Base Address register defines the device local address of a register. The data pointed to by this location is read or written using the Register Data register (PCI config offset 128). When REG_BASE_ADDR has garbage any read or write of Register Data Register (PCI 128) will cause the PCI bus to lock up. The TCO watchdog will fire and bring down the system.
Signed-off-by: Nat Gurumoorthy Acked-by: Michael Chan Signed-off-by: David S. Miller
tg3: Expand multicast drop counter miscounting fix to 5762
commit 4d95847381228639844c7197deb8b2211274ef22 - "tg3: Workaround rx_discards stat bug", added a workaround for miscounted statistics for multicast packets. This fix needs to be applied to the 5762.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Add flag to disable 1G Half Duplex advertisement
Some link partners have issues if the non-standard 1G half duplex is advertised. This patch adds support for an nvram setting to disable the advertisement.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
rxbds_empty is an informational statistic signifying that a ring full condition was observed. It does not mean an overflow has occurred.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 8496e85c20e7836b3dec97780e40f420a3ae2801 Author: Rafael J. Wysocki Date: Sun Dec 1 02:34:37 2013 +0100
PCI / tg3: Give up chip reset and carrier loss handling if PCI device is not present
Modify tg3_chip_reset() and tg3_close() to check if the PCI network adapter device is accessible at all in order to skip poking it or trying to handle a carrier loss in vain when that's not the case. Introduce a special PCI helper function pci_device_is_present() for this purpose.
Of course, this uncovers the lack of the appropriate RTNL locking in tg3_suspend() and tg3_resume(), so add that locking in there too.
These changes prevent tg3 from burning a CPU at 100% load level for solid several seconds after the Thunderbolt link is disconnected from a Matrox DS1 docking station.
Signed-off-by: Rafael J. Wysocki Acked-by: Michael Chan Signed-off-by: David S. Miller
commit 7260899bde50cbe84bdf0a15b5642e2c3b03db32 Author: Ben Hutchings Date: Mon Nov 18 22:59:43 2013 +0000
tg3: Implement the SIOCGHWTSTAMP ioctl
While we're doing this, fix the error code for SIOCSHWTSTAMP ioctl on non-timestamping hardware.
Compile-tested only.
Signed-off-by: Ben Hutchings
commit 58b187c68d91b54b82f6fd267ee3346ed8770655 Author: Ben Hutchings Date: Thu Nov 14 00:40:56 2013 +0000
tg3: Validate hwtstamp_config completely before applying it
tg3_hwtstamp_ioctl() should validate all fields of hwtstamp_config before making any changes. Currently it sets the TX configuration before validating the rx_filter field.
Compile-tested only.
Signed-off-by: Ben Hutchings Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 85aec73d595b8847f9c4ea571deb127913f0d508 Author: Ivan Vecera Date: Wed Nov 6 14:02:36 2013 +0100
tg3: avoid double-freeing of rx data memory
If build_skb fails the memory associated with the ring buffer is freed but the ri->data member is not zeroed in this case. This causes a double-free of this memory in tg3_free_rings->... path. The patch moves this block after setting ri->data to NULL. It would be nice to fix this bug also in stable >= v3.4 trees.
Cc: Nithin Nayak Sujir Cc: Michael Chan Signed-off-by: Ivan Vecera Acked-by: Michael Chan Signed-off-by: David S. Miller
commit d458cdf712e0c671e8e819abb16ecd6e44f9daec Author: Joe Perches Date: Tue Oct 1 19:04:40 2013 -0700
net:drivers/net: Miscellaneous conversions to ETH_ALEN
Convert the memset/memcpy uses of 6 to ETH_ALEN where appropriate.
Also convert some struct definitions and u8 array declarations of [6] to ETH_ALEN.
Signed-off-by: Joe Perches Acked-by: Arend van Spriel Signed-off-by: David S. Miller
tg3: add support a phy at an address different than 01
When phylib was in use tg3 only searched at address 01 on the mdio bus and did not work with any other address. On the BCM4705 SoCs the switch is connected as a PHY behind the MAC driven by tg3 and it is at PHY address 30 in most cases. This is a preparation patch to allow support for such switches.
phy_addr is set to TG3_PHY_MII_ADDR for all devices, which are using phylib, so this should not change any behavior.
Signed-off-by: Hauke Mehrtens Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Commit 989038e217e94161862a959e82f9a1ecf8dda152 ("tg3: Don't turn off led on 5719 serdes port 0") added code to skip turning led off on port 0 of the 5719 since it powered down other ports. This workaround needs to be enabled on the 5720 as well.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit ede23fa8161c1a04aa1b3bf5447812ca14b3fef1 Author: Joe Perches Date: Mon Aug 26 22:45:23 2013 -0700
drivers:net: Convert dma_alloc_coherent(...__GFP_ZERO) to dma_zalloc_coherent
__GFP_ZERO is an uncommon flag and perhaps is better not used. static inline dma_zalloc_coherent exists so convert the uses of dma_alloc_coherent with __GFP_ZERO to the more common kernel style with zalloc.
Remove memset from the static inline dma_zalloc_coherent and add just one use of __GFP_ZERO instead.
Trivially reduces the size of the existing uses of dma_zalloc_coherent.
Realign arguments as appropriate.
Signed-off-by: Joe Perches Acked-by: Neil Horman Acked-by: Jesse Brandeburg Acked-by: Jeff Kirsher Signed-off-by: David S. Miller
While EEH error happens, we might not have network device instance (struct net_device) yet. So we can't access the instance safely and check its link state, which causes kernel crash. The patch fixes it.
EEH: Frozen PE#2 on PHB#3 detected EEH: This PCI device has failed 1 times in the last hour EEH: Notify device drivers to shutdown (NULL net_device): PCI I/O error detected Unable to handle kernel paging request for data at address 0x00000048 Faulting instruction address: 0xd00000001c9387a8 Oops: Kernel access of bad area, sig: 11 [#1] SMP NR_CPUS=1024 NUMA PowerNV : NIP [d00000001c9387a8] .tg3_io_error_detected+0x78/0x2a0 [tg3] LR [d00000001c9387a4] .tg3_io_error_detected+0x74/0x2a0 [tg3] Call Trace: [c000003f93a0f960] [d00000001c9387a4] .tg3_io_error_detected+0x74/0x2a0 [tg3] [c000003f93a0fa30] [c00000000003844c] .eeh_report_error+0xac/0x120 [c000003f93a0fac0] [c0000000000371bc] .eeh_pe_dev_traverse+0x8c/0x150 [c000003f93a0fb60] [c000000000038858] .eeh_handle_normal_event+0x128/0x3d0 [c000003f93a0fbf0] [c000000000038db8] .eeh_handle_event+0x2b8/0x2c0 [c000003f93a0fc90] [c000000000038e80] .eeh_event_handler+0xc0/0x170 [c000003f93a0fd30] [c0000000000cc000] .kthread+0xf0/0x100 [c000003f93a0fe30] [c00000000000a0dc] .ret_from_kernel_thread+0x5c/0x80
Reported-by: Wei Yang Signed-off-by: Gavin Shan Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Turning off led on port 0 of the 5719 serdes causes all other ports to lose power and stop functioning. Add tg3_phy_led_bug() function to check for this condition. We use a switch() in tg3_phy_led_bug() for consistency with the tg3_phy_power_bug() function.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 6829309926b90c4c32d1f4cafeb600cd34a721e3 Author: Daniel Borkmann Date: Tue Aug 13 11:45:13 2013 -0700
net: tg3: fix NULL pointer dereference in tg3_io_error_detected and tg3_io_slot_reset
Commit d8af4dfd8 ("net/tg3: Fix kernel crash") introduced a possible NULL pointer dereference in tg3 driver when !netdev || !netif_running(netdev) condition is met and netdev is NULL. Then, the jump to the 'done' label calls dev_close() with a netdevice that is NULL. Therefore, only call dev_close() when we have a netdevice, but one that is not running.
[ Add the same checks in tg3_io_slot_reset() per Gavin Shan - by Nithin Nayak Sujir ]
Reported-by: Dave Jones Signed-off-by: Daniel Borkmann Cc: Gavin Shan Cc: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The 5762 devices sometimes incorrectly treat udp fragments as RMCP packets and route to the APE. This patch sets the RX_MODE_IPV4_FRAG_FIX bit for these devices which enables the proper behaviour.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The PTP_CAPABLE tg3 devices have a gpio output that is toggled when the free running counter matches a watchdog value. This patch adds support to set the watchdog and enable this feature.
Since the output is controlled via bits in the EAV_REF_CLCK_CTL register, we have to read-modify-write it when we stop/resume.
Cc: Richard Cochran Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Allow NVRAM programming when interface is down
Previously, when the interface was brought down, the driver would set the power state to D3hot. In D3hot, we don't have access to the NVRAM. This patch removes the call to set the power state to PCI_D3hot in close. A following patch will implement the shutdown handler to properly set the D3hot state when the system is going down.
Doing the above means that the TG3_PHYFLG_IS_LOW_POWER should not be checked to validate access to the NVRAM.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
During probe, the driver is incorrectly switching the power to Vaux on the 5717 and later devices. At this point, we are in D0 state and drawing maximum power. We also definitely have Vmain available. It doesn't make sense to switch to Vaux since it has a lesser maximum power draw and we might go over the limit. On a new system, we observe that not all ports are recognized in some of the slots with this call in place.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
When the EEH error is the result of a fenced host bridge, MMIO accesses can be very slow (milliseconds) to timeout and return all 1's, thus causing the driver various timeout loops to take way too long and trigger soft-lockup warnings (in addition to taking minutes to recover).
It might be worthwhile to check if for any of these cases, ffffffff is a valid possible value, and if not, bail early since that means the HW is either gone or isolated. In the meantime, checking that the PCI channel is offline would be workaround of the problem.
Cc: # v3.0+ Signed-off-by: Gavin Shan Signed-off-by: David S. Miller
commit 72bb72b0d98847d22c6fae4e170121f3640f0f60 Author: Michael Chan Date: Mon Jun 17 13:47:25 2013 -0700
tg3: Prevent system hang during repeated EEH errors.
The current tg3 code assumes the pci_error_handlers to be always called in sequence. In particular, during ->error_detected(), NAPI is disabled and the device is shutdown. The device is later reset and NAPI re-enabled in ->slot_reset() and ->resume().
In EEH, if more than 6 errors are detected in a hour, only ->error_detected() will be called. This will leave the driver in an inconsistent state as NAPI is disabled but netif_running state is still true. When the device is later closed, we'll try to disable NAPI again and it will loop forever.
We fix this by closing the device if we encounter any error conditions during the normal sequence of the pci_error_handlers.
v2: Remove the changes in tg3_io_resume() based on Benjamin Poirier's feedback.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Some systems that don't need wake-on-lan may choose to power down the chip on system standby. Upon resume, the power on causes the boot code to startup and initialize the hardware. On one new platform, this is causing the device to go into a bad state due to a race between the driver and boot code, once every several hundred resumes. The same race exists on open since we come up from a power on.
This patch adds a wait for boot code signature at the beginning of tg3_init_hw() which is common to both cases. If there has not been a power-off or the boot code has already completed, the signature will be present and poll_fw() returns immediately. Also return immediately if the device does not have firmware.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
Commit 091f0ea30074bc43f9250961b3247af713024bc6 "tg3: Add New 5719 Read DMA workaround" added a workaround for TX DMA stall on the 5719. This workaround needs to be applied to the 5720 as well.
Cc: stable@vger.kernel.org Reported-by: Roland Dreier Tested-by: Roland Dreier Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The current code calls tg3_set_bdinfo() separately on napi0, followed by a loop that does napi1+. Simplify it by setting bdinfo in the loop for all napi contexts.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Split APE driver state change out of boot reset signature update
Unlike the boot signature that needs to be set before every reset, the ape state only needs to be updated to tell the firmware that the driver is now taking/releasing control of the hardware. Move the calls to tg3_ape_driver_state_change() to better, more appropriate places.
Also, the firmware does not distinguish between SUSPEND and START states anymore. Remove the SUSPEND case in the switch.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Ensure boot code has completed initialization before accessing hardware
After resetting the device, the driver waits for a signature to be updated to know that firmware has completed initialization. However, the call to tg3_poll_fw() is being done too late and we're writing to the GRC_MODE register before it has completely initialized, causing contention with firmware. This logic has existed since day one but is causing PCIE link to go down randomly at startup on one platform once every few hundred reboots.
Move the tg3_poll_fw() up to before we write to the GRC_MODE register after reset.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 1cbf9eb85a6601b58f01a71ff10299d2bf5d3365 Author: Nithin Sujir Date: Sat May 18 06:26:55 2013 +0000
tg3: Implement set/get_eee handlers
Reviewed-by: Ben Li Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 5b6c273ad6c3886f30c7c5df7009e489043c59f3 Author: Nithin Sujir Date: Sat May 18 06:26:54 2013 +0000
tg3: Simplify tg3_phy_eee_config_ok() by reusing tg3_eee_pull_config()
eee_config_ok() was checking only for mismatch in advertised settings. This patch expands the scope of eee_config_ok() to check for mismatch in the other eee settings. On mismatch we will require a call to tg3_setup_eee() to push the configured settings to the hardware.