- Fixed SMP passthrough command failure due to smp back off interrupt. Appears in system log as 0x311c0030. (SCGCQ00889925) - Fixed issue where host boot fails in the presence of blank flash/corrupt firmware in flash (SCGCQ00894439) - Fixed issue where SATA drive errors, bad performance, or boot failure may appear after update to 20.00.02.00 firmware (SCGCQ00859226)(Retain Tip# H015210)
Version 1.20.01 - Moderate Impact/Low Probablility of Occurrence ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.03.00 7.27.04.00
- Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
- Fixed issue where acceptable indistro device drivers may not pass minium driver check. BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal. - Fixed issue where update will not install with the 09.101 megaraid_sas device driver.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
- Fixed SMP passthrough command failure due to smp back off interrupt. Appears in system log as 0x311c0030. (SCGCQ00889925) - Fixed issue where host boot fails in the presence of blank flash/corrupt firmware in flash (SCGCQ00894439) - Fixed issue where SATA drive errors, bad performance, or boot failure may appear after update to 20.00.02.00 firmware (SCGCQ00859226)(Retain Tip# H015210)
Version 1.20.01 - Moderate Impact/Low Probablility of Occurrence ------------- Contains: BIOS Firmware UEFI Driver 7.39.00.00 20.00.03.00 7.27.04.00
- Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Fixes: - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
Adapters Supported: ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304) ServeRAID M5115 SAS/SATA Controller for IBM Flex System (90Y4390)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 23.33.0-0044 - High Impact/High Probability of Occurrence ----------- Fixes: - Fixed an issue where controller may reset under heavy IO and background operations - (SCGCQ00894643) (RETAIN Tip H001154) - Fixed an issue where SuperCap "Battery Not Present" after shutdown and reboot during a learn cycle - (SCGCQ00917115) - Fixed an issue where a VD created with drives from a previously erased VD may disappear on next reboot - (SCGCQ00937912, Port of SCGCQ00900237) - Fixed an issue where firmware may incorrectly select backplane slots when updating drive status - (SCGCQ00980105) - Fixed an issue where MSM shows messages with Error Code 240 and no description - (SCGCQ00970948, Port of SCGCQ00904466) - Fixed an issue where SafeID may change with repeated queries using StorCLI - (SCGCQ00949550, Port of SCGCQ00941577) - Fixed an issue where a Foreign Configuration import may fail after reconstruction when using 4k sector drives - (SCGCQ00830109) - Fixed an issue where setting the Learn Cycle property of iBBU09 gives an I2C error - (SCGCQ00831315) - Fixed an issue where "Prepare for Removal" does not work on a PD when a drive erase is in progress - (SCGCQ00811219, Port of SCGCQ00703189) - Fixed an issue where EFI Driver Health fails when more than 64VDs are configured - (SCGCQ00831006, Port of SCGCQ00830918) - Fixed an issue where a controller may report Cache Memory size as 0 when no logical drives are present - (SCGCQ00837600, Port of SCGCQ00837162) - Fixed an issue where concurrent Consistency Checks cannot be started after issuing "setfactorydefaults" command - (SCGCQ00839437, Port of SCGCQ00838830) - Fixed an issue where Cache Memory size is not reporting 0 when there is no Cache Memory - (SCGCQ00838893, Port of SCGCQ00838193) - Fixed an issue where deleting a CacheCade VD can result in a firmware hang situation - (SCGCQ00838975, Port of SCGCQ00838953) - Fixed an issue where an incorrect error (MFI_STAT_PD_TYPE_WRONG (0x26) instead of MFI_STAT_LD_BLOCK_SIZE_MISMATCH (0x65)) is returned by the firmware when PDs with different block sizes are mixed - (SCGCQ00840251, Port of SCGCQ00836103) - Fixed an issue where BBU status reports Optimal but firmwre logs indicate the BBU has failed - (SCGCQ00838052, Port of SCGCQ00837834) - Fixed an issue where write-verify performance was lower than expected - (SCGCQ00858151) - Fixed an issue where Write-Through and Write-Back cache policies can be changed via Windows Logical Disk Properties - (SCGCQ00856979) - Fixed an issue where firmware reports no SMART error when a PFA (Predictive Failure) drive is attached - (SCGCQ00839455) - Fixed an issue where a status of 0xFF is erroneously returned from StoreLib - (SCGCQ00832673, Port of SCGCQ00827685) - Fixed an issue where an MSM displays an error message if "Schedule Consistency Check" is selected - (SCGCQ00852649, Port of SCGCQ00832908) - Fixed an issue where handling of Functional Level Reset (FLR) is not present - (SCGCQ00854343, Port of SCGCQ00840253)
Enhancements: - Changed the number of Sense Retry counts for a specific video application - (SCGCQ00841000) - Added ability to determine the revision ID for SuperCaps with no VPD programmed - (SCGCQ00828990) - Added support for SES RQST_OK deassertion - (SCGCQ00834321, Port of SCGCQ00817840) - Improved CPLD update capabilities - (SCGCQ00840631, Port of SCGCQ00758178) - Enhanced ability to flush cache with write-verify on RAID0 volumes with SATA drives - (SCGCQ00846777, Port of SCGCQ00842665)
Version 23.33.0-0043 - High Impact/High Probability of Occurrence ----------- Fixes: - Fixed an issue where hard drive slot amber LED not functioning correctly. - Fixed an issue where BBU status says optimal but firmware logs indicate that the BBU has failed (SCGCQ00838052) (RETAIN Tip H214857) - Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350) - Fixed an issue where MR firmware reports "no SMART" error when attaching a PFA drive (SCGCQ00839455) - Fixed an issue where the firmware may hang (enter MonTask) when a guest OS is powered on or off in virtual machine (SCGCQ00854914) - Fixed an issue where MSM displays "The requested command has invalid arguments" error message if 'Schedule Consistency Check' is selected (SCGCQ00852649) - Fixed an issue where the legacy CTRL-H utility may report the wrong PCIe slot number (SCGCQ00799339) - Fixed an issue where the legacy OpROM may show an expander as a JBOD drive in POST (SCGCQ00809682) - Fixed an issue where an encrypted JBOD may be presented to the system in encrypted form even though password was entered incorrectly (SCGCQ00808086)
Enhancements: - Added feature to enable drive fault LED to be lit when a known-bad drive is connected to the controller (SCGCQ00858142) - Added feature to turn on drive Fault LED when the controller detects a drive that was previously marked Bad (SCGCQ00858140)
Version 23.33.0-0018 - High Impact/High Probability of Occurrence ----------- Fixes: - Incorporated MegaRAID FW stack 5.13 - Fixed an issue where drive temperature cannot be displayed for a drive in Failed or Foreign state (SCGCQ00693959) - Fixed an issue where after creating an LD via StorCLI or MSM the firmware writes into saved power condition mode page (0x1a) of all PDs in the LD and enables their idle timers (SCGCQ00658701) - Fixed an issue where Patrol Read would sporadically correct the same defective LBA repeatedly (SCGCQ00729591) - Fixed an issue where importing a Foreign array onto a new controller may fail with "Cannot force emulate VD to 512E since enable512Esupport is false" error in firmware log (SCGCQ00721106) - Fixed an issue where the controller may enter MegaMon sporadically (SCGCQ00776409) - Fixed an issue where MSM may not report a Full Initialization Aborted error until system rebooted (SCGCQ00759100) - Fixed an issue where Link Speed may show UNKNOWN when attaching a 3G or 6G SATA drive (SCGCQ00803522) - Fixed an issue where StorLib may return 0x00ff (fail) code even though operation succeeds when creating a VD out of an existing drive group (SCGCQ00827685) - Fixed an issue where format process of SSD may take much longer than in previous firmware (SCGCQ00674388) - Fixed an issue where controller must have cleared config to enable 240VD unless existing config only included single-drive RAID0 VDs (SCGCQ00559643) - Fixed an issue where some commands would timeout with CDB=ff ff ff ff (SCGCQ00459760) - Fixed an issue where slot ordering in iMR mode might differ from slot numbering in MR mode (SCGCQ00559274) - Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives (SCGCQ00830977) (RETAIN TIP H214323)
Features/enhancements: - Added support for 512e drives (SCGCQ00425363) Enhanced Event Log to include CVPM health details after every Learn Cycle to allow closer monitoring of CVPM health (SCGCQ00819877) - Implemented a retry for reads of CVPM data to avoid erroneous event 386 or 150 in the Event Log (SCGCQ00392439) - Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490819) - Implemented ability for firmware to read drive temperature immediately following SAS discovery (SCGCQ00602573) - Added ability to clear the MaintainPdFailHistory (SCGCQ00474559)
Version 23.29.0-0015 - Suggested ------------------- Enhancement - Provide mechanism to disable PCIe backchannel training via SBR. Fixes: - Fixed an issue where self-encrypting (SED) hard disk password fails to allow access to virtual disk configurations - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where foreign configuration import could fail. - Fixed an issue where storcli.exe /c0 show all command repeatedly prints to termlog with respect to upgradekey presence. - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the order of the first 64 VDs in the POST is not the same sequence as returned from the firmware. - Fixed storCLI adpfwflash option crash and adpallinfo option failure. - Reduced the bootblock Init time, which effectively reduces the configuration retry time to approximately 700 mS.
Version 23.22.0-0024 - Non-Critical ------------------- Enhancement(s): - Display the Native Command Queuing (NCQ) enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI. Fix(es): - Disable PI CRC checking when the drive is not initialized during a CC. - Increased the SuperCap learn time out value for 2GB TMM-B solution. - Fixed an issue for 2GB memory modules where SuperCap does not get connected to the controller and hence cache offload fails. - Fixed an issue where cache policy of virtual drives(VD) does not change to write through(WT) mode even after detecting a bad supercap. - Fixed an issue where a RAID configuration created with physical disks in powersave mode could be losted after rebooting the system. - Fixed an issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed an issue where the system is not allocating memory correctly when MR and iMR controllers are in the same system. - Fixed an issue where deep learn does not start immediately when the relative state of charge (RSOC) is just equal to 95%. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled.
Version 23.16.0-0027 - High Impact/High Probability of Occurrence ------------------- Fix(es): - Addressed data exposure issue when using CacheCade - Fixed issue where Supercap shows 0 Capacitance - Fixed iBBU09 battery issue that caused a VD cache policy to remain in write-through mode after a manual relearn - Fixed iBBU09 battery issue that caused a VD cache policy to periodically toggle between write-back/write-through mode - The limits for iBBU09 battery charging were not updating properly in a learn cycle - Ensures a single supercap pack is not supported on 2GB memory module. - Resolves a firmware crash seen while doing continuous sas cable pulls. - Ensures OpROM loads even if segment address is 0xC0000. - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.12.0-0016 - Suggested ------------------- Fix(es): - Added isync to prevent speculative execution while memory is being allocated. - Delayed enablement of POM until AFTER valid memory range is provided by host system.
Version 23.12.0-0011 - Suggested ------------------- Enhancement(s): - Implemented Limited Band Charging for iBBU09 (RETAIN tip H21631) - Changed BIOS check to determine if running in HAMR, in order to ensure nothing gets broken when user has an iButton which is not programmed. - Changed controller status for safe mode to show controller status as safe mode and disable debug message logging in serial port.
Fix(es): - Addressed an issue where deeply discharged Cache Vault Power Modules would be prematurely be marked as failed. - Fixed an issue where HII hangs when trying to enter configuration management while in safe mode. Changed the safe mode warning message as below: "Controller is running in safe mode. Safe mode is used for diagnostic purposes only. Limited operations such as Configuration Preview, Clear Configuration and View/Change Controller Properties are allowed in this mode. Other operations such as Create Configuration, Import and Clear Foreign Configurations are not allowed. To exit safe mode, correct the fault, and reboot your computer." - Fixed an issue where having more than three adapters results in a calculation error for the offset to store physical disk info for fourth adapter, due to BIOS not clearing upper byte of AX (that is AH which is containing some non zero value). - Fixed an issue where the Wrong spanned drive group size is displayed by WebBIOS (Ctrl-H).
Version 23.7.1-0010 - Suggested ------------------- Fixes: - Fix an issue related to the where the TSOC (EEPROM) is not able to read or write from the firmware which will result in the message "Incompatible secondary iButton present." - Fix a HII broswer issue where Cachecade virtual drive can be selected as a boot device. - Fix a HII broswer issue where the user is unable to clear the controller configuration when there are no drives attached. - Fix an issue where the BIOS doesn't display the RAID level and VD size correctly at BIOS POST.
Version 23.7.1-0009 - Suggested ------------------- Fixes: - Fixed an issue where SoH is bad after a learn cycle but iBBUI shows good status. - Fixed an issue where hi-temp warning was not being displayed.
Version 23.7.0-0037 - Suggested ------------------- Fixes: - Corrected differential signals for Phys 2 and 3 that caused slot numbers in simple swap configurations to be incorrect. - Fixed an issue when 'maintain PD failed history' is enabled, and a cable is removed while a drive is added, the drives state goes to optimal instead of foreign unconfigured bad. - Fixed a problem where a capacity change is reported after a rebuild completes on a Cache Cade volume. - Fixed a controller firmware hang when the recovery of a medium error takes to long. - Fixed an issue where the SATA BBM (Bad Block Manager) list was being corrupted. - Fixed an issue where FoD (Feature on Demand) Options were being lost because of errors while accessing the TSOC. - Fixed a problem where the controller firmware would crash and drives would go offline when a bad block entry was created during a check consistency operation. - Fixed a problem where drives were being marked unconfigured bad (foreign) on reboot. - Fixed problem where a member of a CacheCade volume did not get marked as foreign when the drive was pulled with 'maintain PD failed history' enabled. - Fixed a problem where during a rebuild, a former hot spare that was now in a state of unconfigured good, moved back to the state hot spare, which then automatically started a copyback operation, causing the rebuild to restart. - Fixed a problem where a controller fault occurred during a reboot while a physical device was in progress of a PD Erase.
Version 23.7.0-0029 - Suggested ------------------- Enhancements: - Added support for Cache Cade 2.1 - Added Support for PI Drives
Fixes: - Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup. - Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive - Added a check for the presence of PD before writing the data arms of a protected LD during BGI. - Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS. - Fixed an issue with USB Cacheoffload restore fails after multiple power cycles onServeRAID M51xx controllers. - Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data. - Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash. - Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds. - Fixed background initialization watermark conversion to PD LBA. - Fixed write protected R1E data arms during initialization. - Fixed an issue where MR firmware crashed while discarding pinned cache. - Fixed an issue where a dirty LD dependency information of SSD pd has stale entries. - Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd - Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset. - Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe. - Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM. - Fixed an issue where the firmware was wrongly adding puncture entries. - Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table. - Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event. - Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events. - Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled. - Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value. - Fixed an issue in which a Patrol Read may not start under certain conditions. - Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved. - Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero. - Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU. - Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed. - Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running. - Fixed an issue where CC stops progressing on a R6 VD with media errors. - Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test). - Fixed an issue where controller features are lost if RAID Key was not detected. - Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering. - Fixed an issue where "Native configuration is no longer supported" message in post. - Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low. - Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Version 23.2.1-0043 - Suggested ------------------- Fixes: - Fixed an issue where "Potential non-optimal configuration due to drive PD commissioned as emergency spare" alarm would trigger erroneously. - Fixed an issue where Copyback does not progress upon inserting drives. - Fixed an issue When allowMixInLD is Disabled, and causes Copyback Fails after Rebuild to Emergency Hot Spare. - Fixed an issue where the Firmware faults while flashing. - Fixed an issure where querying SMART / PFA Status to Return all zeros in Sense Data. - Fixed an issue where the Re-inserted Drives becomes Unconfigured_good causing auto rebuilds to fail to start.
Version 23.2.1-0033 ------------------- - Initial release ibm_fw_sraidmr_6gb-23_33_0-0044_linux_32-64_chg
**************************************************************** | | | | | IBM Online Tape Drive/Optical Update Program | | Revision: 1.11.00.1075 Build Date: 6.23.11 | | | | (C) Copyright International Business Machines Corporation | | 2000-2011 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 6/23/2011 | | | ****************************************************************
CONTENTS:
Change History
ver 1.1
Increased the tape tension during drive cleaning from 4g to 7g, which improves the cleaning effectiveness significantly.
ver 1.0
This firmware will change the firmware of your DDS tape drive to the latest available. ibm_fw_tape_dds-1_1_linux_32-64_chg
uEFI Flash Update Version 2.02 (BuildID D7E150C) Change History
Version 2.02 - BuildID: D7E150C ------------------------------------------------- Problem(s) Fixed: - Fixed Abnormal option place for Emulex 4Gb FC in UEFI - Fixed OpenSSL vulnerabilities as reported in CVE Advisories: CVE-2015-1793, CVE-2015-0288, CVE-2015-1789, CVE-2015-1790, CVE-2015-1792
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.91 - BuildID: D7E148B ------------------------------------------------- Problem(s) Fixed: - Updated UEFI to address these vulnerabilities: CVE-2015-0209, CVE-2015-0286, CVE-2015-0287, CVE-2015-0288, CVE-2015-0289 - imm clock drift after ac cycle on dongshan
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.82 - BuildID: D7E146C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Turn off High Precision Event Timer (HPET) from uEFI setting. - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.71 - BuildID: D7E142A ------------------------------------------------- Problem(s) Fixed: - Fixed an issue with continuous reboots when applied new LSI FW and the Remote Console setting is Enabled. Enhancements: Limitations: Dependencies:
Version 1.70 - BuildID: D7E140Z ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58N Version: 4.30 (ibm_fw_imm2_1aoo58n-4.30_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: D7E136W ------------------------------------------------- Problem(s) Fixed: 1. Can not boot up from IMM Remote Mount with USB key. 2. Fixed that LR-DIMM 1333Mhz 1.35V memory speed is incorrect at Balanced mode Enhancements: 1. Support two DIMM Per Channel run at 1866Mhz for 16GB RDIMM 1.5V DR x4 & 32GB LRDIMM QR x4 2. Variable store self-healing. Limitations: 1. When flashing UEFI from version 1.30 or later down to version 1.20 or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30. Dependencies: 1. The IMM firmware must be at BUILDID: 1AOO50D Version: 3.65 (ibm_fw_imm2_1aoo50d-3.65_anyos_noarch) or higher prior to installing UEFI version 1.60. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.50 - BuildID: D7E134E ------------------------------------------------- Problem(s) Fixed: 1. Corrected IPv6 reboot problems 2. Corrected 64bit resouce allocation problems 3. Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot Enhancements: 1. Add support for Intel Xeon processor E5-2600 v2 product family 2. Add notification when UEFI detects GPT corruption during POST 3. Add support to configure the "Next Boot to F1 setup" function out of band 4. Add long text support in F1 setup help string 5. Implement LAN Fail-Over function Limitations: Dependencies:
Version 1.40 - BuildID: D7E128D ------------------------------------------------- Problem(s) Fixed: 1. Fixed that IB mezz card still shows "Standby Power Enable/Disable item" in uEFI setup menu 2. Fixed that can not enter F1 setup menu after 3x POST failure occurred. 3. Correct the PCIE link control of Active-State Power Management(ASPM) setting to result the PCI/NMI problem 4. Fix that UA-101 audio device hang at legacy mode Enhancements: 1. Multiple PCIe adapter BARs 2. Configurable MMIO base 3. Support Firmware first feature 4. Add informational messages when existing UEFI F1 setup menu 5. Add OEM SPD feature 6. Fixed the Preboot Execution Environment(PXE) function with Emulex 10 GbE Virtual Fabric Adapter III Limitations: Dependencies:
Version 1.30 - BuildID: D7E124C ------------------------------------------------- Problem(s) Fixed: 1. Fixed that some USB device hang at legacy mode (UA-101 USB audio device) 2. Disable CPU C-state and phase shedding for Volterra EOS issue Enhancements:
Limitations: Dependencies:
Version 1.30 - BuildID: D7E124A ------------------------------------------------- Problem(s) Fixed: 1. UEFI option 43 failed to work 2. ITP can't trigger CPU2 IERR 3. MBE WHEA-log can't match ECC Uncorrectable event 4. iMM lost connection with shared NIC on Intel mezz card (Meteorite) after power cycle Enhancements: 1. Change UDIMM 2DPC@1333Mhz 1.35V algorithm to meet performance specification requirement 2. Support ROM Recovery feature (Auto Promotion under Backup Bank Management Method) Limitations: Dependencies:
Version 1.20 - BuildID: D7E120C ------------------------------------------------- Problem(s) Fixed: 1. Sevaral uEFI OS boot failed with F12 boot menu HDD0. 2. Console Switch 1754A2X with KB & Mouse are not responding in EFI Web BIOS 3. Multiple issues caused by USB over current, including: 3.1 Unable to use front USB Port to flash firmware, load operating system or install a keyboard/mouse. 3.2 VMWare Purple Screen of Death (PSOD) during OS installation or booting. 3.3 Intermittent USB configuration change under Windows. 4. Fan speed goes to 100% after enable several TPM settings. 5. TPM 1.2 UEFI Preboot Interface Test (found CPU error) Enhancements: 1. Enable DRAM phase shedding 2. Support FastSetup feature 3. Support UDIMM 2DPC@1333Mhz running at 1.35V Limitations: Dependencies:
Version 1.10 - BuildID: D7E116A ------------------------------------------------- Problem(s) Fixed: 1. E5-2690 cannot run frequency at 2.9GHz(only 2.8GHz) when turn off Turbo mode. 2. Instruction for TPM enablement has type error. 3. CPU can not enter deep C status with uEFI 11I under RHEL5.7 64 4. Failed to boot from CDDVD ROM with uEFI OS 5. Best Card cannot link with Gen3 on Mezz Card slot 6. BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event and PCI error LED was off 7. iSCSI ISID mismatch under uEFI BIOS Settings. 8. TCG TPM Integration Test (Manual) random failed under WIN2K8 R2 SP1 with uEFI_11L 9. QPI link speed and Turbo mode show incorrect with M1 stepping CPU. 10.The format of System Event Log is uncorrected 11.Legacy Thunk Support is malfunctional 12.DIMM slot 13-24 can NOT indicate which memory was falut when trigger MBE on Mirror mode by bugged DIMM 13.ASUT74H can't find any iscsi item 14.BestCard ASB_Wiz stress test is failed with Gen 3 link speed 15.Fail to set some of PXE items with ASU76h 16.Can not boot into WinPE in RAID HDD on Crossfield 17.Personality can not be switched in OCM tool no matter FOD is imported 18.Processor speed is incorrect when system is idle 19.VLAN ID can be configured to ID 0 20.PCIX Best Card cannot get software NMI when trigger some of PCIX command 21.10G PCIe slot got incorrect slot error event by PCI-E Best Card 22.PCIe BestCard expr_flow got IERR 23.PCI led on and uEFI report OUT_OF_RESOURCES when system plug-in BussardE 10GbE adapter. 24.Processor speed is incorrect when system is idle w/ E5-2637 M1 25.Console redirection can not work normally with com2com. 26.No screen output with SOL connection 27.iSCSI Attempt will disapper when system reboot several times. 28.BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event on Internal RAID Slot 29.Purple Screen of Death when boot/install ESXi 5.0 to Hypervisor key
Enhancements: 1. Open Optimized Boot setup item with default enable 2. Open Legacy Thunk support setup item 3. Change Operating Mode from Custom Mode to Efficiency - Favor Performance 4. Remove USB port0 OverCurrent Mapping 5. Add DriverCodeDisplay error code on screen function
Limitations: Dependencies:
Version 1.00 - BuildID: D7E112J (Initial Release) ------------------------------------------------- Problem(s) Fixed: 1. High failure rate on front USB cable position/design cause all USB device disappear and could not flash via UXSPI
Enhancements: Limitations: Dependencies:
ibm_fw_uefi_d7e150c-2_02_anyos_32-64_chg
**************************************************************** | | | Tape LTO firmware update | | | | | | (C) Copyright International Business Machines Corporation | | 2000-2012 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 1/29/2013 | | | ****************************************************************
Change History
ver 1.7 To update the LTO 3 v2 firmware to C7RD To update the LTO 4 v1 firmware to C7Q5 To update the LTO 4 v2 firmware to C7RD To update the LTO 5 v1/v2 firmware to C7RD
ver 1.6_01 To update the initilialization file for reflash tool and the new version of LTO Gen 4 v1 firmware into BBH5.
ver 1.6_00 updated firmware for LTO42 to BBNF updated firmware for LTO32 to BBNF ver 1.5_00 updated firmware for LTO 3 to BBNF updated firmware for LTO 4 to BBNF updated firmware for LTO 5 to BBNM
ver 1.4_04
updated firmware for LTO 5 to BBNB
ver 1.4_01
updated firmware for LTO 4 to A23E
ver 1.4_00
updated firmware for LTO 5 to A6S1 updated firmware for LTO 4 to A231
ver 1.3_02
update .txt and .chg files
ver 1.3_01
corrected XML / TML file names for new firmware (A4Q1 -> A5M1)
ver 1.3_00
updated firmware for LTO 5 to A5M1
ver 1.2
updated firmware for LTO 5 to A4Q1
ver 1.1
updated XML / TML to add new systems
ver 1.0
This firmware will change the firmware of your LTO tape drive to the latest available, unless it is already at the latest level.
- IBM HH LTO5 SAS (49Y9898 - 3628L5X - 3628N5X) @ A2C1 - IBM HH LTO1 SCSI (24P2396 - Newton) @ N2CG - IBM HH LTO1 SCSI (24P2396 - Pompy) @ P63I - IBM HH LTO2 SCSI (39M5658) @ 0468 - IBM HH LTO3 SAS (43W8478) @ 93G1 - IBM HH LTO4 SAS (44E8895) @ 93Y1 - IBM FH LTO1 SCSI (00N8016) @ 59C0 - IBM FH LTO2 SCSI (59P6744) @ 8571 - IBM FH LTO3 SCSI (39M5657) @ 87G0 ibm_fw_tape_lto-1_7_linux_32-64_chg
**************************************************************** | | | | | IBM Online Tape Drive Update Program | | Revision: 1.10.01.1073 Build Date: 3.3.10 | | | | (C) Copyright International Business Machines Corporation | | 2000-2010 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 1/28/2013 | | | ****************************************************************
CONTENTS:
Change History
ver 1.6
To release FW v0195. The change from v0185 is to refine the code and no function change for system x.
ver 1.5
Update to fix the failure in FW updating with cartridge inserted in the drive (from v0145 up to v0185). The way to make drive FW update in the VMware environments is added in the readme.
ver 1.4
Initial release of the Tandberg Data RDX USB 3 backup drives. This FW update cover the drives of the IBM P/N 362532Y, 362550Y, 36251TY, 00D2786,00D2787 and 00D2788.
ver 1.1
Updated drive string to include: Imation RDX-USB (in addition to IBM RDX) Updated 'tapedrv' to version 1.10.01.1073 Updated to include more systems
ver 1.0
This firmware will change the firmware of your RD drive to the latest available, unless it is already at the latest level.
This is the initial release of the RD package file, so there are no changes to describe. ibm_fw_tape_rd-1_6_linux_32-64_chg
TMM Firmware Update for ServeRAID M5100 Series SAS/SATA Controllers
Adapters Supported: ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.01.02 - ------------------- TMMB: 70-25842-12 - Fixed issue where update may fail to install
Version 1.01 - Initial release ------------------- TMMB: 70-25842-12 - Fixed issue where CVPM could report "Relearn timeout" during a relearn cycle (Retain Tip H183319) ibm_fw_sraidmr_5100-tmm-1_01_02_linux_32-64_chg
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers
Adapters Supported: ServeRAID M5225-2GB SAS/SATA Controller ServeRAID M5210e SAS/SATA Controller for IBM System x ServeRAID M5210 SAS/SATA Controller
NOTE TO SERVICE - Reference RETAIN #N/A
Version 24.9.0-0029 - High Impact/High Probability of Occurrence ------------------- Fixes: - Fixed an issue where controller cache fails to de-stage when multiple source VDs are present in a CacheCade configuration - (SCGCQ00854169, Port of SCGCQ00842625) - Fixed an issue where a VD created with drives from a previously erased VD may disappear on next reboot - (SCGCQ00900237) - Fixed an issue where StorCLI allows a user to hide a boot drive which is already in the Hidden state - (SCGCQ00885733, Port of SCGCQ00883996) - Fixed an issue where "MonTask: line 245 in file ../../raid/1078int.c" error may be seen when drives are removed in a configuration with 64VDs and CacheCade - (SCGCQ00889884, Port of SCGCQ00878587) - Fixed an issue where some forms out Out-of-band controller management may not display Show Configuration Summary when 240VDs are created - (SCGCQ00910375, Port of SCGCQ00904833) - Fixed an issue where a 'Watchdog Timer Exception' may occur followed by a Fatal FW error after initiating a PD Erase on an Unconfigured Good PD, with Background operations and IOs occurring - (SCGCQ00898359, Port of SCGCQ00872140) - Fixed an issue where Locate may not work on a JBOD physical drive - (SCGCQ00903649) - Fixed an issue where the LUID may change during a Foreign Import from non-240VD FW to 240VD FW - (SCGCQ00907682, Port of SCGCQ00907658) - Fixed an issue where command block latency was too high during Background operations, which could cause a controller firmware hang when deleting a CacheCade VD - (SCGCQ00911790, Port of SCGCQ00865372) - Fixed an issue where medium error correction events were not being surfaced - (SCGCQ00846621) - Fixed an issue where "MonTask: line 1272 in file ../../raid/1078dma.c" error may occur after injecting media errors on loop to a CacheCade VD - (SCGCQ00833945, Port of SCGCQ00822477) - Fixed an issue where deleting a CacheCade VD could result in a firmware hang situation - (SCGCQ00849620, Port of SCGCQ00844698) - Fixed an issue where unexpected Automatic Event Notifications of "Initialization aborted on VD___ due to controller reset" - (SCGCQ00904475, Port of SCGCQ00864348) - Fixed an issue where firmware may report "Disabling writes to flash due to a critical error" - (SCGCQ00917202, Port of SCGCQ00901119) - Fixed an issue where a reconstruction may fail with error "invalid arguments" - (SCGCQ00894719) - Fixed an issue where MSM shows "null x0" to describe port connection to enclosure when multipath is broken - (SCGCQ00898564) - Fixed an issue where an invalid boot device could be selected - (SCGCQ00914515) - Fixed an issue where "Set factory default" does not reset modified PHY link speeds - (SCGCQ00925640) - Fixed an issue where a StorCLI show all command triggers a data store disconnect on a (3) RAID5 VDs in VMWare ESXi - (SCGCQ00928506) - Fixed an issue where FastPath IOs that have timed out may be retried - (SCGCQ00922542, Port of SCGCQ00910124) - Fixed an issue where creation of configuration on a controller fails after the creation of a CacheCade VD followed by a JBOD creation - (SCGCQ00923405, Port of SCGCQ00917307) - Fixed an issue where "Controller encountered a fatal error and was reset" during stress and a is drive pulled - (SCGCQ00929474, Port of SCGCQ00916037) - Fixed an issue where "Adapter at base port not responding" error may occur on boot - (SCGCQ00899333, Port of SCGCQ00880919) - Fixed an issue where MSM shows messages with Error Code 240 and no description - (SCGCQ00904466) - Fixed an issue where handling of Functional Level Reset (FLR) is not present - (SCGCQ00911773, Port of SCGCQ00840253) - Fixed an issue where a "Data Translation Look aside Buffer" error may occur when resetting a target with multiple cable pulls - (SCGCQ00886910, Port of SCGCQ00881919) - Fixed an issue where "MonTask: line 245 in file ../../raid/1078int.c with IOs on max VD configured and BGOps" error may occur - (SCGCQ00898761, Port of SCGCQ00890133) - Fixed an issue where some PDs don't go online after creating a VD on drives with different sizes - (SCGCQ00911685, Port of SCGCQ00834734) - Fixed an issue where firmware might log MR_EVT_CTRL_PR_PROP_CHANGED twice - (SCGCQ00910389, Port of SCGCQ00908165) - Fixed an issue where LUID changes during foreign import from non-240VD firmware to 240VD firmware - (SCGCQ00908894, Port of SCGCQ00907658) - Fixed an issue where "MonTask: line 1278 in file ../../raid/1078dma.c" error may occur after importing PDs with pinned cache - (SCGCQ00913426) - Fixed an issue where "MonTask: line 4946 in file ../../raid/ld.c while multipath push pull with patrol read" may occur when doing multipath cable removals while Patrol Read in progress - (SCGCQ00876061, Port of SCGCQ00857528) - Fixed an issue where imported RAID0 using 4k drives is not visible after reboot - (SCGCQ00910569, Port of SCGCQ00895689) - Fixed an issue where Copyback fails to start and causes a firmware fault - (SCGCQ00908347, Port of SCGCQ00904905) - Fixed an issue where hot removal followed by hot add of a drive into an array causes a Blue Screen of Death - (SCGCQ00923113, Port of SCGCQ00901919) - Fixed an issue where controller report a Fatal Firmware Error and controller reset when creating 240VDs - (SCGCQ00880907) - Fixed an issue where an already-present configuration is showing as foreign after upgrade from non-240VD firmware to 240VD firmware - (SCGCQ00925394) - Fixed an issue where firmware breaks into MonTask when importing a foreign configuration - (SCGCQ00898473, Port of SCGCQ00860066) - Fixed an issue where "Warning Error during boot - Configuration command was not committed, please retry" error occurs on update from non-240VD firmware to 240VD firmware - (SCGCQ00928699) - Fixed an issue where controller may encounter a fatal error and reset during stress and drive removal - (SCGCQ00916037) - Fixed an issue where firmware may hang at "LogInit: Flushing events from previous boot" while running policy change script - (SCGCQ00833849, Port of SCGCQ00797643) - Fixed an issue where a Core 0 Exception may be seen while trying to import a foreign configuration with pinned cache present - (SCGCQ00898730, Port of SCGCQ00863880) - Fixed an issue where PI message "SAS core detected EEDP error in application tag" may occur after firmware upgrade - (SCGCQ00934617, Port of SCGCQ00925591) - Fixed an issue where IO may halt with read/write error when the target drives are reset via MFI or MPT path in Linux - (SCGCQ00893924, Port of SCGCQ00893588) - Fixed an issue where deletion of CacheCade VD the firmware displays the wrong CacheCade target ID and remaining CacheCade size in system - (SCGCQ00898780, Port of SCGCQ00864019) - Fixed an issue where importing 240VD configuration leads to firmware crash - (SCGCQ00922541, Port of SCGCQ00900601) - Fixed an issue where DMA would not halt at first DIF error and go through error recovery mechanism to try and recover the data - (SCGCQ00907673) - Fixed an issue where Random Write performance may drop up to 30% in 2-drive RAID1 with write-back and read-ahead - (SCGCQ00908885) - Fixed an issue where "Controller encountered fatal error and was reset" under heavy IOs and background operations - (SCGCQ00922716, Port of SCGCQ00894643) - Fixed an issue where TTY log dump is not persistent for multiple boots - (SCGCQ00898762, Port of SCGCQ00877100) - Fixed an issue where a CRC mismatch and invalid log event are found while querying for Controller properties - (SCGCQ00934619, Port of SCGCQ00919945) - Fixed an issue where "MonTask: line 1280 in file ../../raid/1078dma.c" may occur when pass-through commands and cable-removal tests are performed at the same time - (SCGCQ00899818, Port of SCGCQ00872875) - Fixed an issue where Windows may Blue Screen of Death when upgrading firmware with driver 6.707.08.00 - (SCGCQ00884589) - Fixed an issue where ECC errors may cause a controller reset - (SCGCQ00849554, Port of SCGCQ00825126) - Fixed an issue where firmware may break into MonTask on reboot after creating 240VDs - (SCGCQ00907679, Port of SCGCQ00905416) - Fixed an issue where discovery may fail with "Unable to get SCSI Device Information from the system" - (SCGCQ00928449) - Fixed an issue where CacheCade performance may be lower than expected - (SCGCQ00911438)
Enhancements Added a feature to block upgrading or downgrading firmware when a reconstruction is in progress, and block reconstructions from starting if a firmware upgrade or downgrade is in progress - (SCGCQ00915869)
Version 24.9.0-0026 - High Impact/High Probability of Occurrence -------------------
Fixes: - Fixed an issue in iMR mode where "Controller encountered fatal error and was reset" errors can occur under heavy IOs and background operations (SCGCQ00894643) (RETAIN Tip H001154) - Fixed an issue where driver health protocol may report unhealthy if more than 64 VDs are configured (SCGCQ00830918) - Fixed an issue where VDs beyond 64 may not be reported in legacy OpROM pOST display list (SCGCQ00826174) - Fixed an issue where "StorCLI /cX add VDs detailed" menu provides incorrect syntax for R1E (SCGCQ00501437) - Fixed an issue where CLI "show all" command fails with error "Error! App exec failed in FW PCLIError! Internal" (SCGCQ00518543) - Fixed an issue where the dedicated hot spare option in HII may be grayed out for RAID1 under the profile based configuration menu (SCGCQ00873973) - Fixed an issue where HII drive management and enclosure management may report only port 4-7 connected when ports 0-3 and 4-7 are connected to the same expander (SCGCQ00870398) - Fixed an issue where HII may hang or multiple enclosure entries will be seen in enclosure eanagement form after repeated navigation (SCGCQ00878350) - Fixed an issue where a 15-character VD name is truncated to 14 characters (SCGCQ00854606) - Fixed an issue where profile-based VD creation menu doesn't explain each profile's drive selection criteria (SCGCQ00884229) - Fixed an issue where some overlap may be seen during legacy OpROM pOST when more than one controller is present and there are boot messages for the second controller (SCGCQ00866982) - Fixed an issue where MSM may display "The requested command has invalid arguments" when 'Schedule Consistency Check' is selected (SCGCQ00832908) - Fixed an issue where a controller may not be accessible through RAIDLink until the OS is up and running (SCGCQ00847001) - Fixed an issue where drive firmware on certain SED/FDE SATA SSDs could not be updated (SCGCQ00856977) - Fixed an issue where an error "MonTask: line 1272 in file ../../raid/1078dma.c" may occur while running IO in a virtual machine (SCGCQ00822403) - Fixed an issue where a JBOD PD may not be able to be converted to Unconfigured Good in Solaris (SCGCQ00834552) - Fixed an issue where an "Instruction TLB" error may occur when a StorCLI /cX set autopdcache=r0 or similar command is executed (SCGCQ00835586) - Fixed an issue where firmware may hang in multipath scenario when cable pull/push test is performed at the same time as an array property change is issued (SCGCQ00836496) - Fixed an issue where a secure erase on a SATA SSD in HII may fail or lead to a hang in HII (SCGCQ00841317) - Fixed an issue where the controller may reset in some situations with media errors and VD undergoing manual rebuild after drives are taken offline, under stress (SCGCQ00825126) - Fixed an issue where the 3x08 chip Errata ID - 2012-RC714 may lead to PCIE 3.0 hot reset non-compliance (SCGCQ00829129) - Fixed an issue where rebuild performance on RAID1 is always slower than other RAID configurations (SCGCQ00841359) - Fixed an issue where patrol read properties window won't show up in MSM (SCGCQ00797676) - Fixed an issue where an L2 unrecoverable cache error may be seen during patrol read properties modification when VDs are made offline (SCGCQ00847162) - Fixed an issue where a VD erase may not resume after reboot when a CacheCade VD is present (SCGCQ00851810) - Fixed an issue where controller boots to OS even when pinned cache is present and boot error handling is set to stop on error (SCGCQ00860503) - Fixed an issue where firmware cannot detect some newly-inserted drives (SCGCQ00860270) - Fixed an issue where "MonTask: line 1518 in file ../../raid/2108vI2o.c" may occur in conjunction with a VMWare Guest abrupt shutdown (SCGCQ00852670) - Fixed an issue where connector name field is displayed as port 4-7 when actually both ports 0-3 and 4-7 are connected (SCGCQ00868215) - Fixed an issue where "line 243 in file ../../raid/1078int.c" error may occur during rebuild (SCGCQ00856256) - Fixed an issue where no error message shown when there is a failure to disable SSD caching of an offline VD (SCGCQ00905310) - Fixed an issue where "1 JBOD(s) found on the host adapter" may appear in legacy OpROM post even though no JBODs are present (SCGCQ00882729) - Fixed an issue where firmware may halt with "line 245 in file ../../raid/1078int.c" in log under stress with maximum VDs and background operations (SCGCQ00890133) - Fixed an issue where the HII may report a different Battery/SuperCap status than MSM/StorCLI would (SCGCQ00879726) - Fixed an issue where the firmware may hang due to an "Illegal Instruction Exception" error (SCGCQ00850441) - Fixed an issue with less-than-expected performance of Write-Verify SCSI commands in RAID0 (SCGCQ00866261)
Enhancements: - Added more descriptive port information to include link width in PHYs (SCGCQ00854621)
Version 24.7.0-0056 - Moderate Impact/Low Probability of Occurrence ------------------- Fixes: - Fixed issue where UNMAP or TRIM commands might fail on SSD in JBOD Mode (SCGCQ00853147) (RETAIN Tip H214381) - Fixed an issue where an iMR RAID configuration may fail to import to 12gbps MR (SCGCQ00833765)
Version 24.7.0-0052 - High Impact/High Probability of Occurrence ------------------- Fixes: Incorporated MegaRAID FW stack 6.6 Fixed an issue where a drive reporting itself as 0MB shows up as Unconfigured Good (SCGCQ00784319) Fixed an issue where the firmware might hang during error handling of sense code 0b/47/xx (SCGCQ00701744) Fixed an issue where some SSDs may cause the system to hang at POST (SCGCQ00595506) Fixed an issue where an iMR RAID config may fail to import to 12gbps MR (SCGCQ00833765) Fixed an issue where R0, R5 and R6 read bandwidth dropped abruptly at 256K block size with 24drive SATA SSD config (SCGCQ00609808) Fixed an issue where RAID10 performance is under-performing (SCGCQ00794773) Fixed an issue where in some cases the LSI chip would convert an incoming chip reset to a system reset (SCGCQ00664261) Fixed an issue where many pRdm/pRequest/pReply messages would appear in LSI firmware log (SCGCQ00752195) Fixed an issue where when a consistency check is aborted, the adapter may reset (SCGCQ00819811) Fixed an issue where Patrol read does not start and gives incorrect warning message (SCGCQ00728404) Fixed an issue where the controller may reset unexpectedly during error handling (SCGCQ00825126) Fixed an issue where StorCLI may report Enclosure Not Found (SCGCQ00843146) Fixed an issue where x880 nodes may report excessive 'SCL STUCK Low! While I2C Rx Receiving Data' in LSI firmware log (SCGCQ00728935) (Retain TIP H213891) Fixed an issue where the command timeout for FED (SED) drives is too short, resulting in 05/2C codes (SCGCQ00797355) Fixed an issue where bandwidth falls as queue depth increases on R5/R6 24/40 drive SAS HDD configs at 256k block size (SCGCQ00701768) Fixed an issue where some drives may get bad PI CRC even though data is correct resulting in drive failure (SCGCQ00819314) Fixed an issue where the firmware may exposed more than 240VDs to host even if host driver doesn't support that many (SCGCQ00829214) Fixed an issue where MSM may display an error message if 'Schedule Consistency Check' is selected (SCGCQ00832908) Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives, preventing data issues (SCGCQ00838953) (Retain TIP H214323) Fixed an issue where the MegaRAID POST may display "The native configuration is not supported by current firmware" (SCGCQ00812842) Fixed an issue where the EFI Driver Health Protocol will show Fail when more than 64VDs are configured (SCGCQ00830918) Fixed an issue where OS may BSOD when upgrading firmware on a controller the OS has booted from if Online Controller Reset is performed (SCGCQ00825725) Fixed an issue where controller wouldn't go to halt state after multibit ECC errors detected (SCGCQ00783186) Fixed an issue where Opal-compliant FDE (SED) drives were being marked as FDE/SED when they shouldn't be (SCGCQ00788250) Fixed an issue where correctable ECC error interrupts were being masked (SCGCQ00814997) Fixed an issue where reconstructed VDs were not being reflected in MSM until system reboot (SCGCQ00839018) Fixed an issue where controller commands may fail when an LD is deleted during reconstruction (SCGCQ00821693) Fixed an issue where firmware would go to MonTask when making VDs offline while a Rebuild is occurring under IO (SCGCQ00825775) Fixed an issue where commands to FDE (SED) drives may not respond within 500ms (SCGCQ00844445) Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00844447) Fixed an issue where HDD/SSD microcode updates may report fail even though they succeeded (SCGCQ00553252) Fixed an issue where slot numbers may be wrong systems with 32 drive slots (SCGCQ00529592)
Features and Enhancements Improved Jetstress / Exchange latencies (SCGCQ00717161) Added support for Learn Cycle debug commands in firmware (SCGCQ00814991) Added ability to clear the MaintainPdFailHistory (SCGCQ00474559) Improved drive rebuild performance (SCGCQ00427581) Improved Cache Offload error handling on read from the flash interface (SCGCQ00524419) Improved average latency and max latency in Windows operating systems (SCGCQ00671670) Implemented power throttling (SCGCQ00457280) Improved load balancing on >2 drive R1 VD of SSDs (SCGCQ00593588) Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490822) Added support for communicating with multiple controllers over I2C (SCGCQ00485924) Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00651680) Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00399739) Improved accuracy of ROC temperature display (SCGCQ00575037) Increased range of priorities for background tasks, CC/PR/Rebuild/Migrate/BGI (SCGCQ00313882) Added support for 512e drives (SCGCQ00619363) Prevented a situation where there may be excessive overtemp warnings in the firmware log (SCGCQ00820067) Improved DDR3 signalling margin during heavy I/O workloads (SCGCQ00824711)
Version 24.2.1-0052 - Non-Critical ------------------- Enhancement(s): - Added a special handling for interactive password. - Implemented mechanism to allow system BIOS to put entries for iMR memory allocation into proper table. Fixes: - - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key.resent. - Fixed an issue where foreign configurations fails to import maximum number of configurations. - Fixed simpleswap port mapping. - Fixed an issue where 'Cli show all' command fails with error msg 'Error! App exec failed in FW PCLIError! Internal.' - Fixed an issue where ‘Cli show all’ command fails with error message ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an issue where Coherency bit was not enabled in SRAM TLBs.
Version 24.2.1-0045 - Non-Critical ------------------- Fixes: - Fixed an issue where cache offload failured with pinned cache on R5 VD. - Fixed an issue where using upper case characters in command 'cli set securitykey' fails with error code '1001' and error message 'invalid key.' - Fixed an issue where system would not boot into legacy mode. - Fixed an issue where default setting of VD doesn't reflect MFC's setting. - Fixed an issue where ‘Cli show all’ command fails with error msg ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an where ServeRAID M5210 showed the wrong slot numbers in both MR and iMR, in both HII and MSM.
Version 24.2.1-0027 - Non-Critical ------------------- Enhancment(s): - Added support for ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade for IBM System x (47C8668) - Added event in firmware to indicate that an INIT operation was halted due to reboot or other failure Fixes: - Increase backplane support to 32 slots. - Enable 512E support. - Fixed an issue where system is not allocating memory correctly when MR and iMR are in the same configuration - Fixed an issue where the user is Unable to create a RAID10 through Ctrl R using 4k drives. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled. - Fixed an issue where switching between external key management (EKM) and Local Key Management (LKM) without rebooting results in the current secret key string becoming invalid/null. - Fixed an issue where cache memory size is listed as zero in controller Information. - Fixed an issue where re-keying a controller with External key management (EKM) enabled and rebooting the system results in a corrupted key ID and an error message "Unable to communicate with EKMS ..." is displayed. - Fixed an issue where performing an online firmware update or online controller reset (OCR) on a controller with External key management (EKM) enabled, results in all secured drives marked as foreign. - Fixed an issue where CacheCade volumes, which are not supported, could be created using 4K SSD's. - Fixed an issue where removing the last physical drive of arrays could result in a firmware fault. - Fixed an issue where MegaRAID Storage Manager does not show an option to create virtual drives when the first drive in the array is missing in a partial virtual drive where all drives are configured. - Fixed an issue where switching the security mode from external key management (EKM) to local key management (LKM) on iMR controller will result in a corrupted controller key. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect.
Version 24.0.2-0013 ------------------- -Initial release ibm_fw_sraidmr_5200-24_9_0-0029_linux_32-64_chg
ServeRAID M1000 Series SAS/SATA Controller Firmware Update
Adapters Supported: ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
Version 20.13.1-0245 - Moderate Impact/Low Probability of Occurrence --------------------- - Fixed an issue where virtual drivers become inconsistent after the system an AC failure. (SCGCQ00897229) - Fixed an issue where Illegal request sense messages are seen repeatedly in FW logs due to attempts to collect temperaure for pds which does not support page (0x2F) at every smart poll interval. (SCGCQ00898459) - Fixed an issue where command "cli set securitykey=Lsi@12345" fails with error code "1001" and error message "invalid key". - Added a warning message when preboot configuration utility is Disabled but the user tries to launch it. (SCGCQ00662761) - Fixed an issue where WebBIOS Advance software option menu from main page could hang the system. (SCGCQ00683327) - Updated the drive speed display string to support 12Gb/s (SCGCQ00751036) - Corrected inconsistency in size showing in for total capacity property between webBIOS and MSM (SCGCQ00752176)
Version 20.13.1-0200 - Critical ------------------- Enhancement: - Display drive speed for 12 GB Seagate hard drives in MSM. - List battery status in BIOS as N/A for iMR controllers Fixes: - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where WebBIOS advanced software option locks the server. - Changed patrol read completion time calculation to include time for associated IO operations. - Fixed SGPIOs signal issue.
Version 20.11.1-0184 - Suggested ------------------- Fixes: - Updated SBR to avoid an errata that could cause correctable CPU errors on some systems. - Fixed an issue where NULL events may show in event log, preventing capture of controller event logs.
Version 20.11.1-0137 - Suggested ------------------- Enhancement(s): - Update recovery mode page (WriteRetryCount and recoveryTimeLimit) during discovery of a drive and during spinup recovery when sense 6/29 is received.
Fixes: - Fixed an issue where certain drives were reporting a temperature of 65 degrees Celsius. - Fixed an issue where systems with SSD HDD will pop up an error message after creating a virtual drive via HII on M1115. - Fixed an issue where the drive state is not modified when a recon virtual drive is created from the reboot path.
Version 20.10.1-0107 - Suggested ------------------- Fixes: - Fixed grammatical errors in WebBIOS. - Fixed an issue in WebBIOS Drive Group Definition screen where enclosures should not be selectable in the Drives column. - Fixed an issue in uEFI-WebBIOS where the white bars do not match up under VD properties page. - Fixed an HII browser issue where a drive performing a copyback displayed the state as "Replacing" but other utilities showed the state as copyback. - Fixed an HII browser display issue where SATA drives showed "0" for the value of RPM under drive properties. - Fixed a display issue where the HDD port number showed incorrectly in an HII browser. - Fixed an HII browser issues where creating a global hotspare gave the user an error message. - Fixed an HII browser issue when security is changed with local key management the changing security report current mode is disabled as external keu management. - Fixed an HII browser issue where the user got the following error message, "The request command has invalid arguments," when changing the security key report. - Fixed an HII browser issue where the user was unable to save the configuration after adding an extra span during array creation. - Fixed an HII browser issue where the return value was not correct when the browser called extract config with a result of null.
Version 20.10.1-0101 - Suggested ------------------- Fixes: - Fixed an issue where a system uefi error will occur when the bootTargetId is set to 0. - Fixed a problem where the firmware will allocate the sata bbl entry for the drive when moved from unsupported to supported. - Fixed a firmware issue where the TargetId for the recon LD should be set to its original LD. - Fixed a HII error message "Question Value mismatch with Option value!" after selecting factory defaults in HII. - Fixed an issue where the firmware fails to create the configuration and utilities fail to report the VD size after the reconstruction.
Version 20.10.1-0091-01 - Non-Critical ------------------- Fix - Fixed issue where update may fail to find all supported controllers in SLES 11 SP 2. Note not change in the firmware; it is the same as package 20.10.1-0091.
Version 20.10.1-0091 - Suggested ------------------- Enhancement: - Add support for ServeRAID M1115
Fixes: - Fixed issue where after starting a reconstruction on a RAID 0 the progress %, does not increase. - Fixed an issue where a new drive, inserted after a drive failure, goes to JBOD and not auto rebuild. - Fixed physical drive count issue that stated more than (16) devices already exists
Version 20.10.1-0069- Suggested ------------------- Enhancement: - ServeRAID M1015 Dimmer Switches are disabled by default.
Fixes: - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Fixed issue where WebBIOS gives garbled message when enabing FDE on an existing Disk Group - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed a problem where firmware was taking to long to complete the PCI config read. Causing the system to generate an NMI. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed an intermittent RAID key failure during power-on.
Version 20.10.1-0052- Critical ------------------- Enhancement: - Add support to pass SMART errors for JBOD drives to MSM
Fixes: - Added check to return SCSI sense Check condition if PMI is set and LBA is non zero for SCSI Read Cap 16. - Fixed issue where a bluescreen occurs handling RAID 1 with HSP and medium errors. The bluescreen occurs becausethe driver timesout while fw is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early
Version 20.10.1-0045 - Critical ------------------- Fix: - Fixed issue where firmware has incomplete writes during power fail and recovery
Version 20.10.1-0036 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users to downlevel firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur
Version 20.10.1-0022 - Critical ------------------- - Fixed issue where Windows 2008 R2 WS08 cannot be installed properly on ServeRAID M1015 SATA JBOD with a uEFI boot. - Added warning message when user tried to change more then 16 drives to JBOD. - Addressed a problem where direct attached drives are given incorrect slot numbers - Added fixes from LSI channel products. - Fixed issue where a single JBOD drive will not boot after a Windows 2008 R2 installation.
Version 20.5.1-0014 - Critical ------------------- - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed problem where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 20.1.1-0059 - Critical ------------------- Fixes: - Fixed an issue where a physical drive that is changed to JBOD from powersave will become unconfigured good again - Addresses an issue where data becomes inaccessible when a drive is secured after data has been written
Version 20.1.1-0049 - Suggested ------------------- Enhancement - Support M1000 key for RAID 5 and SED support
Fixes: - Fixed an issue in M3950M3 where webbios would hang - Fixed an issue where the controller properties in WebBIOS such as Rebuild, CC and BGI are not changing when we use up and down arrow keys. - Fixed an issue where Enclosure ID's are not being shown in MSM
Version 20.1.1-0046 - Suggested ------------------- - Enabled support for the ServeRAID M1000 Series Advanced Feature Key.
Note: All Logical Drives must previously have the encryption enabled before data is written on to the SED drives. Please read Retain TIP H123152 for more details.
Version 20.1.1-0042 ------------------- - Initial release ibm_fw_sraidmr_1000-20_13_1-0245_linux_32-64_chg
BIOS/FW/UEFI Update for IBM N2200 Series SAS/SATA HBA Controllers
Controller Supported: IBM N2215 SAS/SATA HBA for IBM System x (47C8676) IBM N2225 SAS/SATA HBA for IBM System x (00AE912) IBM N2226 SAS/SATA HBA for IBM System x (00AE916)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.09.04 - Moderate Impact/Low Probability of Occurrence --------------- Contains: BIOS Firmware UEFI Driver 08.21.06.00 09.00.02.00 10.00.00.00
Fixes: - Fixed issue where HDD removal not properly reported as Target Device missing when attached to adapter through an expander. (SCGCQ00777858) - Fixed issue where Fault State (0x265d) is observed in driver logs while connecting an enclosure with fully populated SATA drives (SCGCQ00856085) - Fixed issue where 0x7C54 fault seen during I/T switching (SCGCQ00847013) - Fixed issue where certain drive pull scenarios result in longer time to discovery running (~3+ seconds) (SCGCQ00843759) - Improved PCIe Config operation handling to avoid 0x0D03 faults (SCGCQ00836878) - Fixed issue where controller could fault with 0x4A00 during link break (SCGCQ00793956) - Fixed the occurrence of fault 0x1708, when a free MID is attempted to be failed to the host. (SCGCQ00826420) - Fixed occurrence of fault 0x5814/0x5813 while handling Task Management during IO Timeout (SCGCQ00865024) - Fixed issue where SATA drive with slow spin up can cause IO timeout in Linux. (SCGCQ00869554) - Fixed system hang after adapter reset with heavy IO load (SCGCQ00877099) - Fixed issue with slow BIOS interface response with certain hardware e nvironments (SCGCQ00888867) - Fixed UEFI issue where in an environment with multi-lun devices where lun size varies, backup GPT corruption can occur (SCGCQ00907441)
Enhancements: - In BIOS added a new field to Device Properties called "Logical Sector Size". The possible values are 512B, 4K and Unknown. (SCGCQ00887338) - Improved the response time in UEFI HII utility for SAS3 IT/IR Controllers (SCGCQ00821793)
Version 1.07 - Moderate Impact/Low Probability of Occurrence --------------- Contains: BIOS Firmware UEFI Driver 08.15.01.00 07.00.01.00 08.00.00.00 Firmware:
Fixes: - Fixed issue where 0xD025 fault appeared while running non-FastPath I/O to SATA disk with outstanding FastPath I/Os to SAS disk (SCGCQ00604668) - Fixed fault 0xD071 while running stress and glitching all 4 phys as part of a cable break test. (SCGCQ00590502) - Fixed MPI Power Management Global Request Change to Reduced or Standby state results in "Operation State Not Supported" or "IOC Busy" (SCGCQ00584284) - Fixed issue where when transitioning MPI Power Management speed from lower to higher rate the command falsely reported as successful (SCGCQ00584288) - Fixed issue with mixture of FastPath IO's and standard firmware path IO's timing out on SATA disks (SCGCQ00576190) - Fixed SATA only issue where Multiple 'Write Verify' SCSI commands with zero data length leads to f/w fault (0x4203 or 0x4C31). (SCGCQ00549293) - Fixed fault 0x6230 while disabling expander phys and running stress in multi-path failover environment (SCGCQ00692652) (SCGCQ00699059) - Fixed various conditions causing 0x6230 fault when cable breaking (SCGCQ00669775) (SCGCQ00699057) (SCGCQ00643835) - Fixed issue where rapid successive controller resets would cause HBA to stop responding on the PCIe bus (SCGCQ00556766) - Fixed issue where when phy power management is enabled, TARGET RESET function fails yet command is reported a success. (SCGCQ00570820) - Fixed issue where PCIe Link Down can cause transmit margin field to not reset resulting in PCIe validation tests failing (SCGCQ00663185) - Fixed issue where SCSI command is not failed with expected response when SATA drive undergoing a format operation and reserved fields are set as Non-Zero value (SCGCQ00679566) - Fixed issue where read log ext command wasn't issued by PL FW to recover from error during the failure of write verify command (SCGCQ00675166) - Fixed IOC fault state 0x1609 caused by Message Unit Reset (SCGCQ00582515) - Fixed issue where SAS Phy page 1 and 2 error counters wrap around when maximum values are reached. (SCGCQ00651231) - Fixed fault 0x265D when running large block IO with higher Qdepth (SCGCQ00600832) - Fixed issue in Transport Layer Retries Code causing 0x265D and 0x0501 faults (SCGCQ00609576) - Fixed issue where Bad TLB entry causes 0x26B5 fault in IT/IR firmware (SCGCQ00629210) - Fixed 0x6828 fault when using large CDB (SCGCQ00614498) - Fixed fault 0x1901 seen when running Unmap IO’s during task aborts for a SATA drive (SCGCQ00711858) - Fixed issue where system gets hung & reboot while running IO's along with diag reset on the Controller which has Active and Inactive volumes. (SCGCQ00714125) - Fixed issue where cards would fault with 58B4 on power up due to incorrect SERDES setting (SCGCQ00728903) - Fixed WRITE SAME(10) and WRITE SAME(16) SCSI commands fail on last LBA of SATA Drive, incorrectly reporting logical block out of range. (SCGCQ00703433) - Fixed fault 0x4203 when WRITE AND VERIFY (16) command us executed to SATA Drive for LBA Out of Range (SCGCQ00705320) - Fixed issue where ATA Translation of sector count in sense data is inconsistent for READ DMA pass-through cmd (SCGCQ00712688) - Fixed issue where CLI command to dump L1 data cache causes 0x265D fault (SCGCQ00715317) - Fixed SATA Init problem causing 0x6230 controller fault (SCGCQ00683795) - Fixed fault 0x265D hit when booting controller with attached enclosure (SCGCQ00709712) - Fixed issue where Negotiated Physical Link Rate in SAS IO Unit Page 0 may not be correct after pulling a cable (SCGCQ00696408) - Fixed issue in NVDATA where SGPIO PHYs reversed (SCGCQ00750746) - Fixed I2C slave status interrupt not always cleared with I2C Write operation (SCGCQ00731646)
Enhancements: - Improved implementation of SCSI transport layer (SATL) handling while the SATA drive is in security 'frozen' state (SCGCQ00549302) - SCSI Transport Layer: Indicate support for the ATA Device Server Password security protocol (SCGCQ00625580) - IO Processor Target Mode performance improvements (SCGCQ00685827)
UEFI:
Fixes: - Fixed issue where the navigation of HII screens was very slow when no drives are connected to an expander (SCGCQ00569123) - Reduce the boot time for UEFI driver for large configurations (SCGCQ00498101) (RETAIN Tip H212119) - Fixed issue where HII configuration utility did not print the complete SAS address (SCGCQ00709781) - Fixed issue where View Physical Disk Properties screen on HII was not showing correct disk details (connector:encl:slot) when more than 8 disks are directly attached. (SCGCQ00691104)
Enhancements: - Obtain the Physical Slot number from the PCI Bridge first and use fall back to SMBIOS table if unable retrieve slot number from PCI Bridge. (SCGCQ00498095) - Retry Test Unit Ready command if drive foes not respond on first try. (SCGCQ00518198) - Adding a small delay (2 seconds) to get proper operation status after starting an operation (like consistency check) in HII (SCGCQ00621480) - Enhanced HII configuration utility to display tape drive information (SCGCQ00700835)
BIOS:
Fixes: - Fixed issue where the system boot hangs when Legacy BIOS is disabled (using HII) on certain UEFI systems. (SCGCQ00637088) - Fixed issue where the Legacy BIOS failed to detect certain large capacity SAS drives (SCGCQ00696486)
Enhancements: - Support configurable timeout for Start Stop Unit Command. (SCGCQ00694336)
Ehhanncements: - Add support for N2225 and N2226 SAS/SATA HBA Controllers Fixes: - Fixed an issue where SAS SSDs may not show up in the uEFI configuration Utility (HII)