************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read.
RETAIN TIP: H214635 MIGR-5098037
SAS 3.5"
- ST2000NM0034, ST4000NM0034, ST6000NM0034 to BC6B - similar to Note * above.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5J - Enhance Dither Algorithm to prevent dwelling during Idle environments. - ST2000NM0043, ST4000NM0043 to EC5E - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SAS 2.5"
- TXA2E21600GA6I to GB7P - add support in profile.
- HUC156030CSS20, HUC156060CSS20 to J2G6 - add support in profile.
SATA 3.5"
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB68 - similar to Note * above.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5F - Enhance Dither Algorithm to prevent dwelling during Idle environments.
SATA 2.5"
- MTFDDAA120MBB, MTFDDAA240MBB, MTFDDAA480MBB, MTFDDAA800MBB to MB42 - add support in profile.
- SSDSC2BB080G4I, SSDSC2BB160G4I, SSDSC2BB300G4I, SSDSC2BB600G4I to D201NB39 - add support in profile.
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.17.01 - Update Utility release for IBM x86 servers.
Note: * - Fixed extremely low probable data compare error on I/O held in standby when followed by power cycle; extremely low probable data compare error due to nonvolatile cache(NVC) write data not getting written to disc. RETAIN TIP: H214784 - MIGR-5098277
Note: # - Fixed a block misalignment during a sequential read. RETAIN TIP: H214635 MIGR-5098037
This package acknowledges support of qualified devices and may include updates for drives with product ID strings of:
SAS 3.5"
- HUS724020ALS61, HUS724040ALS61 to N3L6 - internal updates.
- ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5H - See Note * above.
- ST2000NM0054, ST4000NM0054, ST6000NM0054 to EC66 - see Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- Other drive codes are present for support identification.
SAS 2.5"
- WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA34 - follow-on release. - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC33 - follow-on release.
- HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EH - follow-on release.
- TXA2D20200GA6I, STXA2D20400GA6I, TXA2D20800GA6I, TXA2E21600GA6I to GB7P - enhancements.
- ST300MM0006, ST600MM0006, ST900MM0006 to B56T - See Note * above.
- ST300MM0026, ST600MM0026, ST900MM0026 to E56E - See Note * above.
- ST2000NM0043, ST4000NM0043 to EC5D - See Note * above.
- ST1200MM0007 to B57E - See Note * above.
- ST1200MM0017 to E577 - See Note * above.
- HUSMM1620ASS20, HUSMM1640ASS20, HUSMM1680ASS20, HUSMM1616ASS20 to J4C8 - See Note # above - HUSMM1620ASS20E, HUSMM1640ASS20E, HUSMM1680ASS20E, HUSMM1616ASS20E to N4C8 - See Note # above
- Other drive codes are present for support identification.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1D - performance inhancements.
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5C - See Note * above.
- ST2000NM0024, ST4000NM0024, ST5000NM0024, ST6000NM0024 to BB65 - See Note * above.
- WD2003FYYS-23W0B0 to WA36 - configuration additions.
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD39 - configuration additions.
- HUA723030ALA6 to MKAOA930 - enhancements. - HUA723020ALA6 to MK7OA930 - enhancements.
- Other drive codes are present for support identification.
SATA 2.5"
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXT0CA34 - ship level.
- Other drive codes are present for support identification.
SATA 1.8"
- Drive codes are present for support identification.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.05 Build ID: IBM11605
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.05 - Update Utility release for IBM x86 servers.
This package acknowledges support and may include updates for drives with product ID strings of:
SAS 3.5"
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4B - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L6 - Fixed unexpected 02/04/11 error; Fixed a drive logic self-initiated reset on read/write long commands; Fixed a problem with large write sequential transfers.
SAS 2.5"
- ESXSST9500620SS, ESXSST91000640SS to BD2K - ensures that after servicing an 03/11/00 error, an index for Parity Creations is calculated correctly after a power cycle, that would otherwise make the drive unresponsive.
SATA 2.5"
- SSDSC2BB012T4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix.
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.04 Build ID: IBM11604
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.04 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SATA 2.5"
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB42 - > A drop in host power supply may cause bad block growth > The bad block table may not properly increment > Background activity may continue after STANDBY, STANDBY IMMEDIATE, or SLEEP > ID173/202 may show incorrect value when the NAND erase count exceeds 3000 > Changed DRAM timing > Event log may be programmed when supply voltage from host is out of specification
- SSDSC2BB012I4I, SSDSC2BB016T4I to G201NC32 - SCT WriteSame fix that corrects a condition that may cause the drive to not respond.
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND34 - will require two update runs and system reboots for device fw update to complete--Please See the limitations in readme for details.
> Performance improvement on sub-4KB sequential write > Fix drive reports higher than actual data units read and write > Fix drive incorrectly counts unsafe power shutdown events on warm reboots
IBM Online SAS/SATA HDD/SSD Update Program. Version 1.16.03 Build ID: SAS11603
************************************************************************** IBM SAS/SATA HDD/SSD Update Program Version 1.16.03 - Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST2000NM0034, ESXSST4000NM0034, ESXSST6000NM0034 to BC67 - GA code. - ESXSST2000NM0054, ESXSST4000NM0054, ESXSST6000NM0054 to EC66 - GA code.
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA39 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SAS 2.5"
- ESXSTXA2D20200GA6, ESXSTXA2D20400GA6, ESXSTXA2D20800GA6, ESXSTXA2E21600GA6 to GB7P - fixes implemented to support PI issues.
- ESXSST300MP0005 to B675 - GA code. - ESXSST300MP0025 to E671 - GA code.
- ESXSST300MP0035, ESXSST600MP0035 to B683 - GA code. - ESXSST300MP0045, ESXSST300MP0045 to E685 - GA code.
- ESXSST300MX0012, ESXSST600MX0052 to BH53 - GA code.
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23DS to ZA34 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; drive was reporting 0B/11 instead of 03/11. - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC33 - issues fixed: slow performance with PI enabled; drive hang on uncorrectable rd error in reallocation track; PERSISTANT RESERVATION command not working correctly; reliability improvements around off-track write protection.
SATA 3.5"
- MG04ACA200E, MG04ACA300E, MG04ACA400E, MG04ACA500E to SJ1C - GA code
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE2B - Update configuration change.
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB34 - > Some Out of Range LBAs accepted by NCQ commands where they should be aborted. > SataDownShift.srt failed, Smart attribute Raw lost with perform dirty pwr cycle . > Low Power Entry Bug Identified from Marvell Code Review > Track Timeout, Marvel 373 sequencer issue > Unreasonable ECC count in SMART ID 195
************************************************************************** IBM Online SAS/SATA HDD/SSD Update Program for Linux. Version 1.16.00 Build ID: SAS11600
******************************************* IBM SAS/SATA HDD/SSD Update Program Version 1.16.00 - First Update Utility release for IBM System x servers.
This package acknowledges support and may include updates for drives with product ID strings of:
NOTE: Check notation under PCIe NVMe devices.
SAS 3.5"
- ESXSST1000NM0023, ESXSST2000NM0023, ESXSST3000NM0023, ESXSST4000NM0023 to BC5E
- ESXSST2000NM0043, ESXSST3000NM0043, ESXSST4000NM0043, ESXSST1000NM0043 to EC5A
- ESXSST3300557SS, ESXSST3450757SS, ESXSST3600957SS to EA54
- ESXSST3300657SS, ESXSST3450857SS, ESXSST3600057SS to BA5A
- ESXSST33000650SS to BC3E
- ESXSST1000NM0001, ESXSST2000NM0001 to BC4A
- ESXSHUS724020ALS64, ESXSHUS724030ALS64, ESXSHUS724040ALS64 to J3L5
- ESXSHUS724020ALS61, ESXSHUS724040ALS61 to N3L5
- ESXSHUS723020ALS64, ESXSHUS723030ALS64 to J3K8
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to
- ESXSWD1001FYYG-23S, ESXSWD2001FYYG-23S, ESXSWD3001FYYG-23S, ESXSWD4001FYYG-23S to XA38
SAS 2.5"
- ESXSTXA2D20200GA6I, ESXSTXA2D20400GA6I, ESXSTXA2D20800GA6I, ESXSTXA2E21600GA6I to GB7H
- ESXSST300MM0006, ESXSST600MM0006, ESXSST900MM0006 to B56M; - ESXSST300MM0026, ESXSST600MM0026, ESXSST900MM0026 to E56D
- ESXST1200MM0007 to B57B - ESXST1200MM0017 to E576
- ESXSST9300605SS, ESXSST9600205SS, ESXSST9900805SS to B55E - ESXSST9300505SS, ESXSST9600105SS, ESXSST9900705SS to E558
- ESXSST9146853SS, ESXSST9300653SS to B63K
- ESXSST9146753SS, ESXSST9300553SS to E638 - ESXSST9500620SS, ESXSST91000640SS to BD2J
- ESXSHUC101212CSS60 to J2MA - ESXSHUC101212CSS61 to N2M9
- ESXSHUC156030CS420, ESXSHUC156060CS420 to J5G2 - ESXSHUC156030CSS20, ESXSHUC156060CSS20 to J2G4
- ESXSHUC156030CS420E, ESXSHUC156060CS420E to N5G2
- ESXSHUC156030CSS20E, ESXSHUC156060CSS20E to N2G4
- ESXSHUC101860CS420, ESXSHUC101890CS420, ESXSHUC101812CS420, ESXSHUC101818CS420 to J5H2 - ESXSHUC101860CS420E, ESXSHUC101890CS420E, ESXSHUC101812CS420E, ESXSHUC101818CS420E to N5H2
- ESXSHUC109030CSS60, ESXSHUC109060CSS60, ESXSHUC109090CSS60 to J2EG - ESXSHUC109030CSS61E, ESXSHUC109060CSS61E, ESXSHUC109090CSS61E to N2EG
- ESXSAL13SXB300N, ESXSAL13SXB600N to SC36
- ESXSMBF2300RC, ESXSMBF2600RC to SB2F
- ESXSMK1401GRRB, ESXSMK3001GRRB to SC2E - ESXSMK1401GRRR, ESXSMK3001GRRR to SF23 - ESXSMK3001GRDB, ESXSMK6001GRDB, ESXSMK9001GRDB to SB35
- ESXSWD3001BKHG-23D, ESXSWD6001BKHG-23D, ESXSWD9001BKHG-23D to ZA33 - ESXSWD3002BKTG-23E, ESXSWD6002BKTG-23E, ESXSWD9002BKTG-23E to ZC32
- EXSXHUSMM1620ASS20, EXSXHUSMM1640ASS20, EXSXHUSMM1680ASS20, EXSXHUSMM1616ASS20 to J4C6 - EXSXHUSMM1620ASS20E, EXSXHUSMM1640ASS20E, EXSXHUSMM1680ASS20E, EXSXHUSMM1616ASS20E to N4C6
SATA 3.5"
- WD1003FBYX-23Y7B0, WD2003FYYS-23W0B0 to WA35
- WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD37 - Resolves drive initiated reset (DBS (Debug Stop event)) encountered under a narrow timing window (~1ns) for specific command/access patterns, due to the drive’s handling of command automation where it was possible for an internal hardware resource conflict to occur between two tasks.
- ST33000650NS to BB3A
- ST1000NM0011, ST2000NM0011 to BB4A
- ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB5A
- HUA723020ALA640 to MK7OA930 - HUA723030ALA640 to MKAOA930
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NSto BE2A
- MTFDDAK120MBB, MTFDDAK240MBB, MTFDDAK480MBB, MTFDDAK800MBB to MB33
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to 5DV1NA37
- MZ7GE240HMHP-000M3, MZ7GE480HMHP-000M3, MZ7GE960HMHP-000M3 to EXST0CA34
PCIe NVMe 2.5"
- SSDPE2ME400G4I, SSDPE2ME800G4I, SSDPE2ME016G4I, SSDPE2ME020G4I to 8DV1ND32 - will require a system reboot for device fw update to complete. ibm_fw_hdd_sas-1_18_03_linux_32-64_chg
IBM Flex System x440 UEFI Flash Update Version 1.60 (BuildID CNE148B) Change History
Version 1.60 - BuildID: CNE148B ------------------------------------------------- Problem(s) Fixed: - Fix CVE-2015-0286, CVE-2015-0287, CVE-2015-0289, CVE-2015-0209, CVE-2015-0288 by updating to OpenSSL 0.9.8zf Enhancements: N/A Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.50 - BuildID: CNE146D ------------------------------------------------- Problem(s) Fixed: - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made by 3rd party configuration utilities - Fixed a problem where the IO adapter inventory was not getting updated after replacing the adapter - Fixed a Unified Change Management (UCM) MriName GUIDed opcode handling issue - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570 - Made a change so that Unified Change Management (UCM) will support opcodes in backup format for the regressed group ID format on Emulex ethernet controllers Enhancements: Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.40 - BuildID: CNE142A ------------------------------------------------- Problem(s) Fixed: - Incorporated Intel Memory Reference Code (MRC) update 2.0.0.3 - Incorporated Intel Microcode Update (MCU) MED306E4_00000427 - Fixed memory type programming for 64-bit PCI resources on multisocket systems Enhancements: - Added support for Agentless configuration - Enabled RAID link feature on Storage Expansion Node Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.30 - BuildID: CNE136N (Suggested) ------------------------------------------- Problem(s) Fixed: - Limited PXE support to four devices Enhancements: - Added support for TKLM Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.21 - BuildID: CNE126J (Suggested) ------------------------------------------- Problem(s) Fixed: - Updated high Memory Mapped Input/Output (MMIO) base address to allow use of this memory in VMWare systems - Added code workaround for VRD master soft shutdown issue - Updated "Memory Refresh setting" to remove 4x selection to synch up with latest chipset vendor support statement Enhancements: Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release. - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.20 - BuildID: CNE126G (Suggested) ------------------------------------------- Problem(s) Fixed: - Improved handling of missing values for iSCSI initiator name - Corrected handling of pre-boot serial port redirection settings - Corrected garbled SOL output strings during early phases of UEFI booting - Clarified actions required to effect changes to Trusted Platform Module (TPM) setup - Corrected failure to load some default settings on CMOS battery failure - Improved wording for progress codes and messages - Corrected the order in which UEFI configures Ethernet ports - Improved handling of USB configuration changes - Corrected boot configuration problem Enhancements: - Updated DMI Type 17 support for for new memory devices - Improved support for 32GB memory - Improved general Reliability/Availability/Serviceability support - Added ability to resize PCIE IO base address registers dynamically - Improved handling of memory in high stress application/usage - Added ACPI Firmware First logging support - Added setup capability to select PCIE Config Base below 4GB - Added informational messages when exiting UEFI F1 Setup Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO39E Version: 2.00 (ibm_fw_imm2_1aoo39e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Enhancements: Add support for automatic ROM recovery Add support for dynamic debug capability Improve Update Security Improve Configuration Support Add common support for OS-4690
Limitations: When flashing UEFI from version 1.30 or later down to version 1.2x or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation.
No errors are logged when flashing from an earlier version to version 1.30.
The IMM firmware must be at version ???? or higher prior to installing UEFI version 1.30. If it is not, the UEFI update module will be rejected as invalid because of additional security features implemented in this release.
Dependencies:
Version 1.00 - BuildID: CNE120Q (Initial Release) ------------------------------------------------- Problem(s) Fixed: Corrected errors in SMBIOS Table Type 9 Slot ID (09h) Corrected errors in correlating SEL Events with UEFI Auxilliary Data Corrected problems in setting boot order Corrected problems in loading pDSA image UEFI event ID not showing up in logs for double bit memory errors Enhancements: Support VLAN Enable Rank Based PFA Protocol Reduced the idle power consumption by gating power to unused devices Added a prompt in setup to save settings after modifying Operating Mode Added the Embedded Hypervisor as a default boot option Add support for LRDIMMS Limitations: Dependencies: ibm_fw_uefi_cne148b-1_60_anyos_32-64_chg
=============================================================================== Emulex FC/FCoE Device Driver for Linux ===============================================================================
Device Driver Version: 10.3.135.0 Supported On: Flex
Problems Fixed: - Error recovery of a "hung" IO to a device is cancelling ALL IOs, not just the culprit one only - A NULL pointer dereference kernel panic occurs in lpfc_target_reset_handler()
Incremental Interoperability: - SLES 12 - RHEL 6.6, 7.1 - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.375.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - ELS txcmplq list corruption cause crash during error injection - Cleaned up several issues around ExpressLane feature - Need a HAL workaround for upgrading 10.0 XE102/XE104 f/w to 10.2 - I/O hang on RHEL6.5 for small block (4K) random i/o on POWER8
Device Driver Version: 10.0.800.0 Supported On: IBM System x
Problems Fixed: - Low bi-di throughput seen on 1g ports of HS-23 LOM - Multiple performance improvements - Bonding driver takes approx 20 seconds to be ready
Incremental Interoperability: - RHEL 5.10 - RHEL 6.5 - XE-102 and XE-104 ASIC (OCx14xxx) - Support for set and get channels ethtool operation
Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.4 and above 64-bit with KVM * SLES11 SP3 and above 64-bit with KVM
NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest.
Device Driver Version: 8.3.7.27 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Execution of internal loopback causes a crash - Issue which can cause multipath failover to not work properly
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x and BladeCenter
Device Driver Version: 8.3.7.18 Supported On: IBM System x and BladeCenter
Problems Fixed: - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - OXID Reused before RA_TOV without RRQ to recover - Intermittently storage paths will not recover after switch reboot
Device Driver Version: 8.3.6.4 Supported On: IBM Flex
Problems Fixed: - Fixed debug helper routine failed to dump CQ and EQ entries in non-MSI-X mode - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - Fixed boot from san failure when SLI4 FC device presented on the same PCI bus - Fix ABTS recovery to be FC spec compliant - Fixed not reporting logical link speed to SCSI midlayer when QoS not enabled - Fix performance problem in pt2pt mode - Fixed SCSI host create showing wrong link speed on SLI3 HBA ports - Update text for misconfigured port messages - Fix discovery bug when swapping cables
Interoperability since previous release: - RHEL6.3 GA Kernel
Device Driver Version: 8.3.5.86 Supported On: IBM System x and BladeCenter
Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service
Interoperability since previous release: - RHEL6.3 GA Kernel
Device Driver Version: 8.3.5.74 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix compilation errors on some kernels due to debugfs variable definitions - Used PCI configure space read to flush PCI function reset register write - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset
Device Driver Version: 8.3.5.66 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fixed port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix KERNEL allocation while lock held - Incorrect usage of bghm for BlockGuard errors - Fix warning on i386 system - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Support character device to take a reference on the driver - Fix for FDISC failures after firmware reset or link bounce - Support debugfs for injecting T10 DIF errors - Fix SLI4 BlockGuard behavior when protection data is generated by HBA - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Support more driver logs in area of SLI4 port error attention and reset recovery - Fix bug with driver returning the wrong ndlp - Sync up with actual upstream lpfc driver code - Support SLI4 16Gb FC Adapter support for T10 DIF / BlockGuard - Merge from upstream: scsi: Fix up files implicitly depending on module.h inclusion - Fix driver behavior when receiving an ADISC - Fixed unbounded firmware revision string from port caused the system panic - Fix bug with driver processing dump command type 4 using 16Gb FC Adapter - Fix driver does not reset port when reset is needed during fw_dump - Fix ELS FDISC failing with local reject / invalid RPI - Changed SLI4 FC port internal loopback from outer serdes to inner internal - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix bug with driver processing an els command using 16Gb FC Adapter - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtained link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed SLI4 16Gbit FC port internal and external diagnostic loopback tests - Fixed system panic during EEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing shost lock protection on setting/clearing bit in vport->fc_flag - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed illegal state transition during driver unload - Fixed system crash on SLI4 FC port looopback diagnostic test with large buffers - Fixed a potential error path that might try to free DMA memory not allocated - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix memory leak when running hba resets to SLI-4 board - Fix driver message 3092 and 3116 to KERN_WARNING - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Support loop for sli4 fc pass-through - No longer read fcoe parameters if board is not fcoe - Fix bug with driver passing a wrong count value - Support restore state and error log when sysfs board_mode attribute access failed - Fixed a typo in two of the log messages just introduced - Support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS. Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Return an error if the mbox sysfs is called - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when ASIC fails to initialize - Fix virtual fabrics bit set in FLOGI incorrectly - Fix bug with driver not returning extended mailbox data - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Modify WQ handling to use entry_repost - Moved link type definitions to apply to all driver streams - Support a sysfs attribute "protocol" to report SLI4 port link protocol type - Support SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Support structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fixed a warning when converting from simple_strtoul to strict_strtoul - Support Initial code to inject T10 DIF errors - Fixed a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Fixed null pointer dereference after clearing FCP policy rules - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Support check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fix sysfs lists fabric name for port that has been disconnected from fabric - Support FCP policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed fcp underrun reporting - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Support proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Fix compiler warning due to uninitialized local variable - Fix bus reset handler fails with bad failure code - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed sysfs API mismatch for building against SLES11 SP2 beta kernel - Fixed scsi midlayer queuecommand API mismatch for SLES11 SP2 beta kernel - Fixed ctlreg write bug not checking key string and limiting bytes to write - Fix default adapter name for the OCe15100 - Fixed incomplete scsi messages displayed - Fix cable pull failure on interface type 2 SLI-4 adapters - Fix enable_bg config parameter for SLI4 - Fixed not able to perform firmware reset through sysfs board_mode attribute - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix request firmware support for little endian systems - Fix driver firmware to match new firmware image format - Fixed SLI4 device firmware reset with SR-IOV virtual functions - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed handling of CVL for vports - Fixed crash when aborting els IOs - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Support fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - Fix issue where the FC/FCoE Async Receive CQE did not scale for 16G FC adapters - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Removed unused argument passed to the lpfc_bsg_diag_mode_enter routine - Fixed new ASIC device-mgmt BSG pass-through failed multi-buffer fw download - Support sysfs logging when writeable parameters are changed - Used PCI config space capability for sysfs get PF supported SR-IOV number of VFs - Support wait for SLI port status register for readyness following firmware reset - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - Consolidated duplicating macro definitions - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Modified log messages for T10-PI processing - iDiag fixed mailbox capture and dump overlapping bitmap macro definition
QLogic IBM Flex System FC5172 2-port 16Gb Multiboot Update for FLEX. Firmware Change History March 20, 2015
QLogic Corporation. All rights reserved.
The files contained in this Flash image package are zipped into a file that will expand to provide the following versions for the 8300 Series Adapters.
* Flash Image Version 4.71.07
HLD47107.BIN contains: ---------------------- * FC Bootcode (2600 Series only) BIOS 3.0 version 2.14 (BOFM) uEFI version 6.21 Signed FCode version 4.09 * FC Firmware - v7.05.04 * Pegtune - v5.110.9 * CRBnit - v5.14.15
Change History: -------------------------------
Date : 01/09/2014 Version : 3.80.05 Firmware: 7.01.00 BIOS: 2.14
-------------------------------
Date : 07/22/2013 Version : 2.02.65 Firmware: 6.07.00 BIOS: 2.14
Broadcom NetXtreme I Firmware Update Utility for IBM servers and options using the Broadcom NetXtreme I ethernet adapters.
Version 17.2.4.1a, July 23, 2015
This update package supports the following Broadcom devices: =========================================================== - BCM5717 NetXtreme I LOM - BCM5718 NetXtreme I LOM - BRCM5718 NetXtreme I Gigabit Ethernet Adapter / Product No: 49Y7900 - BCM5719 NetXtreme I LOM - BCM5719 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9352 - BCM5720 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9370
This update packages updates your Broadcom LOM/Adapter Firmware Code to the levels shown below: Firmware code: Version Previous ==================== ======== ========== Bootcode for 5717 1.65 << 1.63 Bootcode for 5717C0 2.10 << 2.07 Bootcode for 5718 1.65 << 1.63 Bootcode for 5719 1.43 << 1.41 Bootcode for 5720 1.39 << 1.36 EFI Undi 17.2.1* << 17.0.11 iSCSI Boot 17.0.0 17.0.0 PXE NX1 17.2.0 17.2.0 NCSI Firmware NX1 1.3.12 << 1.3.07
Note: An asterisk (*) following a version number represents a certified driver. Arrows (<<) between versions indicate the component has been updated from the previous released software kit.
brcm_fw_nic_17_2_4_1a_linux_32-64_chg
=============================================================================== Emulex NIC Device Driver for Linux ===============================================================================
Device Driver Version: 10.3.142.0 Supported On: Flex
Problems Fixed: - None
Incremental Interoperability: - SLES 12 - RHEL 6.6, 7.1 - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.363.0 Supported On: System x and BladeCenter
Problems Fixed: - Multiple performance improvements in virtualized environments (SR-IOV,UMC) - Resetting Transparent Vlan to Default Vlan is not working - Cleanup ethtool set settings code - ARI on IBM x3650M4: All functions are not displayed in Linux
Device Driver Version: 10.2.261.0 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Provide link state control for VFs - ethtool shows port as fibre though copper cable is connected. - Multi channel config should be determined via port resource descriptor - Showing WoL supported in ethtool for BE3 where it is not supported - be2net driver crash when umc enabled - ip link show command shows vlan for vfs although vlan creation is failed on the vfs - Emulex be2net driver does not support IOMMU pass through mode
Device Driver Version: 10.0.800.0 Supported On: IBM System x
Problems Fixed: - Low bi-di throughput seen on 1g ports of HS-23 LOM - Multiple performance improvements - Bonding driver takes approx 20 seconds to be ready
Incremental Interoperability: - RHEL 5.10 - RHEL 6.5 - XE-102 and XE-104 ASIC (OCx14xxx) - Support for set and get channels ethtool operation
Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.4 and above 64-bit with KVM * SLES11 SP3 and above 64-bit with KVM
NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest.
Device Driver Version: 4.6.267.4 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV configuration section of the Linux NIC Driver Documentation has been modified to improve clarity
Incremental Interoperability: - S3 Resume on IBM Flex - SLES 11.3 on IBM System x and BladeCenter
Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.3 and 6.4 64-bit with KVM * SLES11 SP2 and SP3 64-bit with KVM
NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest.
- Use of SR-IOV with the XEN hypervisor is not supported at this time.
- Use of SR-IOV with the KVM hypervisor requires the use of macvlan network interfaces.
Device Driver Version: 4.6.148.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - Ethernet performance issues in a variety of workloads - VFs are not displayed after driver re-load when is VFs attached to VM - vLAN tagging in Switch Agnostic vNIC mode
Incremental Interoperability: - RHEL 5.9 - RHEL 6.4 - Network performance varies with workload. An ethernet driver tuning script and instructions is now included with the be2net driver. - Switch Independent Mode within hypervisor OS's
Known Issues: - Multi-channel is not supported in RHEL5.x XEN. This is a kernel limitation - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV is not supported with RHEL5.x XEN
Device Driver Version: 4.4.180.0 Supported On: IBM Flex
Device Driver Version: 4.2.389.0 Supported On IBM System x and BladeCenter
Problems Fixed: - Unloading the driver hangs the system after running IPv6 traffic - Link status messages cleaned up when in Switch Agnostic mode - Miscellaneous network performance issues to improve throughput - Miscellaneous problems related to SRIOV to improve usability - Ethtool wol command displays wol enabled even when disabled - Ethtool speed reported as 10000Mb/s for disabled devices in Switch Agnostic mode
Incremental Interoperability: - RHEL6.3 GA Kernel - Increase default B/W for SRIOV vf's to 10Gb from 100Mb
Device Driver Version: 4.1.413.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - WOL changes for Linux NIC driver as mentioned in Bug# 24543 - SR IOV UE when attempt to do multiple (3 times) driver load/unload - Speed is 10000Mb/s for Disabled devices in UMC Mode - Incorrect Duplex value is shown for unconnected port of NC552m in Rhel6.1 32bit - SLES 11 SP2 GMC: Enable support for Lnx NIC Driver - SRIOV: When VGT is configured for a VF, ip link show doesn't display it for the VF configured. - RHEL 5.8 GA: Enable support for Lnx NIC Driver - ip link command with vlan = 4095 has toggling effect - ip link command with vlan =0 should remove guest VGT privilege
Device Driver Version: 4.1.334.39 Supported On: IBM System x and BladeCenter
Problems Fixed: - SR-IOV: Can't load be2net driver in a VM after the VM has been rebooted - SR-IOV: Unload PF driver with VF driver loaded causes system instability - SR-IOV: VF MAC always gets Emulex OUI - SR-IOV: Partition the limited per port VLAN entries across VFs and PFs - Non Member VLAN packets not received in interface promiscuous mode in BE3 - Avoid CQ full condition in HW - be2net: use RX_FILTER cmd to program multicast addresses - account for skb allocation failures in ethtool stats - Support 60 second delay to Linux NIC driver to allow FAT dump completion on recovery from EEH - Link status is up [ethtool and OCM] when the bandwidth is assign 0 for UMC configuration - Remove msix module parameter - Use V1 version of COMMON_NTWK_LINK_STATUS_QUERY for Lancer. - Emulex: Ethtool failing to update FW - Emulex: Panic in be2net driver in SLES11-SP2-B7 on adapter - TCP ACKs from different connections are getting received in single queue - Multicast filtering feature not working on PPC - Exit of mcast promiscous mode not working - VLAN promiscous mode cannot be set on Lancer - Can't communicate after changing MAC address via VLAN interface - Improper memory accounting in received packets - WOL changes for Linux NIC driver as mentioned in bug - Transparent VLAN tagging feature not working in SR-IOV
=============================================================================== Emulex iSCSI Device Driver for Linux ===============================================================================
Device Driver Version: 10.3.139.0 Supported On: Flex
Problems Fixed: - None
Incremental Interoperability: - SLES 12 - RHEL 6.6, 7.1 - Lenovo branded versions of formerly IBM branded products
Device Driver Version: 10.2.365.0 Supported On: System x and BladeCenter
Problems Fixed: - be2iscsi rpm is failing with dependencies error - Unable to iSCSI SAN install RHEL/SLES/WIN2012R2 with UFP - Server is getting rebooted when we run IPv4+IPv6 bi-di NIC traffic simultaneously on UMC enabled interfaces
Device Driver Version: 10.2.261.1 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Write error while running traffic - System crashed after running converged IO with driver load unload in a - Possible backlog of eq might happen if _process_cq keep processing for a long time: causes fw UE - Driver memory leak resulting in "DMA: Out of SW-IOMMU space" errors in dmesg file output
Device Driver Version: 10.0.803.21 Supported On: IBM System x
Problems Fixed: - Unable to OEMSEAddTarget or OEMSEDiscoverTaget successfully and get entries in mili2d.log - Emulex drivers are not working on RHEL5 and RHEL6 errata kernel updates - IO Read/Write almost halts with 'DMA: Out of SW IOMMU space' messages while running iSCSI Multipath I/O
Device Driver Version: 4.4.175.0 Supported On: IBM Flex
Problems Fixed: - Cleaned up a cosmetic problem with warning messages during driver compile from source - System crashes when we run simultaneous IO to 6 vNIC’s with iSCSI IO - Linux kdump kernel crashes during shutdown after capturing dump, if be1iscsi driver running
Device Driver Version: 4.1.402.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - LUN is not getting detected for OEM CNA in SLES 11 SP2 64 bit OS - ioctl semaphore deadlock when running load/unload loop with target - SLES 11 SP2 GMC: Enable support for Lnx iSCSI Driver - RHEL 5.8 GA: Enable support for Lnx iSCSI Driver
Device Driver Version 4.1.334.39 Supported On: IBM System x and BladeCenter
Problems Fixed: - Emulex: Warning messages seen while building Emulex drivers on RHEL platform - Unable to load be1iscsi driver during iSCSI boot OS install - Modprobe be1iscsi hangs when system with max targets login - be1iscsi unload hangs the system - fw rebooted on 1st mbox cmd after driver load > unload > load - Failed to initialize iscsi driver - need to define DMA_32BIT_MASK / DMA_64BIT_MASK in Linux kernel 3.x.x
Integrated Management Module II (IMM2) Firmware Update Change History
Version 5.20, 1AOO68L - Supports systems: HS23, HS23E, x3100 M4, x3250 M4, x3100 M5, x3250 M5, x3550 M4, x3650 M4, x3500 M4, x3630 M4, x3530 M4, x3300 M4, x3650 M4 BD, x3750 M4, x3850 X6, x3950 X6, dx360 M4, nx360 M4 - Firmware changes to address security vulnerabilities: CVE-2015-4000, CVE-2015-1789, CVE-2015-1790, CVE-2015-1792, CVE-2015-1791 CVE-2014-8176, CVE-2013-4560, CVE-2013-4508, CVE-2013-4559, CVE-2015-1799 CVE-2015-1788, CVE-2015-5600, CVE-2013-2207, CVE-2014-8121, CVE-2015-1781 CVE-2015-5722 - Re-enabled the EDH cipher for the ldap client - Fixed a problem where setting NIST800-131A mode on the web, CLI, and SNMP is inconsistent - Fixed a problem where the signed certificate status on the web and the CLI does not match - Fixed a problem on x3650 M4 where the "NvDIMM Status & Cables" sensor does not de-assert - Fixed a problem where the DIMM's Manufacturer ID information is not displayed - Fixed a problem where the password is not changed after setting the password via OneCLI - Fixed a problem where a user cannot log using ldap Active Directory Application Mode - Fixed a problem on x3850 X6 where the IMM2 does not detect power supply faults and over- temperature conditions - Fixed a problem on x3500 M4/x3550 M4/x3650 M4 where the IMM2 reports power supply configuration mismatch assertion and deassertion events within seconds - Re-enabled TLS1.0/TSL1.1 support for the web and WS-MAN interfaces when the IMM2 is in NIST mode - Fixed a problem on x3100 M4/x3250 M4 where there is no alert message logged when AC power is lost
Version 4.97, 1AOO66M, Supported Platforms: HS23, HS23E, x3100 M4, x3250 M4, x3550 M4, x3650 M4, x3500 M4, x3630 M4, x3530 M4, x3300 M4, dx360 M4, x3750 M4, x3100 M5. x3250 M4, xc360 M4, x3650 M4 BD, x3850 X6, x3950 X6 - NOTE: To avoid possible exploits of the vulnerabilities discovered with SSLv3 encryption, support for SSLv3 has been removed from the IMM2 firmware. To access the IMM2 web interface using https, users must make use of client browser versions that support TLS1.2 encryption. Refer to RETAIN Tip H214507 for details. - After applying this firmware update all subsequent self-signed certificates are generated using SHA-2 cryptographic hashes. Certificate signing requests are also generated using SHA-2 cryptographic hashes if the IMM2 is configured to run in NIST SP 800-131A Compliance mode. - Critical Fix for x3750M4 -- Fixed issue on missing power supply redundancy lost event - Firmware changes to address security vulnerabilities: CVE-2015-2808, CVE-2015-0204, CVE-2014-3566, CVE-2014-3511, CVE-2014-3509, CVE-2014-3505, CVE-2014-3506, CVE-2014-3508, CVE-2014-5139, CVE-2014-3507, CVE-2014-3510, CVE-2013-4332, CVE-2014-3513, CVE-2014-3567, CVE-2014-3568, CVE-2014-3569, CVE-2014-3570, CVE-2014-3571, CVE-2014-3572, CVE-2014-8275, CVE-2015-0205, CVE-2015-0206, CVE-2015-0286, CVE-2015-0287, CVE-2015-0289, CVE-2015-0292, CVE-2015-0209, CVE-2015-0288. - Fixed a problem that IMM2 unable to detect event from redundant PSU on x3250 M4 - Fixed a problem that PSU 1 and PSU 2 will show changed after hot swap on x3250 M4 - Fixed a problem that FAN will rotate in high speed when booting on 3100 M4 - Fixed a problem that IMM2 LDAP connects to AD server three time simultaneously for each login attempts with wrong password - Fixed a problem that Fan operates abnormally in S5 mode after rebooting system on x3550 M4 - Fixed a problem that "ipmitool chassis status" reporting false drive fault on System x3650 M4 - Fixed a problem that IMM firmware version 4.56 display as 4.55 in DSA log and UEFI data - Fixed a problem that IMM2 cannot log events on x3550 M4 - Fixed a problem that IMM2 may reset due to potential memory leakage - Fixed a problem that failure to send the alert of IMM2 via e-mail - Fixed a problem on IBM NeXtScale nx360 M4 for where the IMM may intermittently report an incorrect DC value to IBM NeXtScale n1200 Fan and Power Control (FPC) - Fixed a problem on NI152 x3650M4 where the IMM may report a power supply configuration mismatch error message in the system event log
Version 4.90, 1AOO66O - Non-critical - Firmware changes to address security vulnerabilities: CVE-2015-2808, CVE-2015-0204, CVE-2014-3566, CVE-2014-3511, CVE-2014-3509, CVE-2014-3505, CVE-2014-3506, CVE-2014-3508, CVE-2014-5139, CVE-2014-3507, CVE-2014-3510, CVE-2013-4332, CVE-2014-3513, CVE-2014-3567, CVE-2014-3568, CVE-2014-3569, CVE-2014-3570, CVE-2014-3571, CVE-2014-3572, CVE-2014-8275, CVE-2015-0205, CVE-2015-0206. - Fixed a problem that IMM firmware version 4.56 displays as 4.55 in DSA log and UEFI data. - Fixed a problem that IMM2 may reset due to a potential memory leakage. - Fixed a cooling issue when the Fusion IO adapter is present - Fixed a problem where the IMM2 LDAP authentication attempts to connect to an AD server three times simultaneously for each login attempt with a wrong password. - Fixed a problem that may cause the IMM2 to fail to send an alert via e-mail. - To support new security requirements the IMM firmware now requires the Java remote presence client to be at version 1.8 or newer
Version 4.80, 1AOO64T - Supports IBM System x3850/x3950 X6, Machine Type: 3837, 3839 - Fixed potential problem where Service Advisor not functional when routing through a proxy server
Version 4.61, 1AOO64Y - Fixed a problem on IBM NeXtScale nx360 M4 for intermittent IPMB IO error and ME error. - Fixed a problem on IBM NeXtScale nx360 M4 for unexpected shutdown due to CPU over temperature
Version 4.58, 1AOO64V - Critical - Critical Fix for x3630 M4, x3530 M4, x3300 M4, x3650 M4 BD -- Removed an incorrect error message sometimes displayed when certain RAID adapters are installed in certain PCIe slots
Version 4.56, 1AOO64S - Critical - Critical Fix for x3650 M4, x3650 M4 HD, x3650 M4 BD, x3500 M4, x3630 M4, x3530 M4, x3300 M4 -- Fixed issue on missing power supply redundancy lost event
Version 4.55, 1AOO64N - NonCritical - Firmware changes to address security vulnerabilities: CVE-2014-3508 CVE-2014-3509 CVE-2014-3505 CVE-2014-3506 CVE-2014-3507 CVE-2014-3510 CVE-2014-3511 CVE-2013-2174 CVE-2013-4545 CVE-2014-0015 CVE-2014-0138 CVE-2014-0139 CVE-2014-2653 CVE-2014-2532 - Closed network port 121. - Fixed a problem of I2C error on x3500 M4 systems with use of Fairmont Raid card with FW version 23.22.0-0024 and iMM 1AOO58T - Thermal behavior enhancement on System x iDataPlex dx360 M4 - Fixed a problem that Call Home function was not working with a Proxy server
Version 4.31, 1AOO58T - Critical - Critical Fix for x3650M4, x3550M4, x3500M4, dx360M4, x3100 M4, x3250m4, x3750M4, x3650M4 HD, x3630M4, x3530M4, x3300M4, x3250M5 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198 - Added option to export the certificate signing request in PEM format - Various Remote Presence enhancements including: -- Support for a MAC OS-x client -- Scaled video viewer window -- ASU set up of Remote Presence hot keys -- Virtual media mounting via URL - Removed potentially sensitive information from the service data file - Fixed a problem on x3650 M4, x3550 M4, x3500 M4, x3650 M4 HD where the IMM2 may not detect a loss of power supply redundancy - Fixed a problem where the LDAP group filter does not support a full DN - Fixed a problem where the syslog alert fields "Msg Type" and "Severity" did not follow RFC 5424 - Fixed a problem where the IMM2 only supported the default network port for syslog notifications - Fixed a problem where the SNMP "sysName" query always returns the string "SNMP Service" instead of the system name - Fixed a problem where the Global Login Settings changes were lost after an IMM2 restart
Important: Before you flash the IMM2 firmware back to version 3.82 or older, set the IMM2 Security option to use the Basic Compatibility Mode. This will prevent a possible loss of access to the IMM2.
Version 4.15, 1AOO58K - Suggested - Added support for the BIE (Blade IO Expansion Board) on the HS23, HS23E - Fixed a problem that prevented the AMM from controlling power when local power control is disabled on the HS23, HS23E
Version 3.91, 1AOO56P - Critical - Critical Fix for IBM NeXtScale nx360 M4 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 3.90, 1AOO54X - Added support for the IBM NeXtScale PCIe Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.83, 1AOO56I - Critical Fix for x3250 M5, nx360 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.73, 1AOO56D - Critical - Critical Fix for dx360 M4, x3650 M4, x3550 M4, x3500 M4, x3100 M4, x3250 M4, x3750 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.71, 1AOO52W - Critical - Critical Fix for x3550 M4: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a problem system may shut down with new Mezz card installed
Version 3.70, 1AOO52Q - Critical - Critical Fix: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882)
Version 3.67, 1AOO50G - Initial Release - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.65, 1AOO50D - Suggested NOTE: If you have a System x3550 M4 with the "Emulex VFA Mezz card" and a ==== single processor, don't update the IMM2 with this firmware - Critical Fix: -- Fixed a problem on the System x3650 M4 server where the system shuts down due to a false temperature event from the ambient temperature sensor - Fixed a problem where the IMM2 may erroneously report a fan fault in the x3630 M4 when the system is powering on. See RETAIN tip H207461 for the description of the original problem - Fixed a screen refresh problem where it occurs after resetting IMM2 - Fixed a firmware problem that may cause the IMM2 to reset unexpectedly - Fixed a problem where the IMM2 SNMP interface may intermittently be unavailable if the system is running VMWARE ESXi 5.x - Fixed a problem where the CPU may potentially throttle in the x3650 M4 system with two 550 watt power supplies and one hard drive backplane
Version 3.60, 1AOO50C - Suggested - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM - Corrected a problem that caused the IMM to report an "Unsupported blade/blower combination" error on HS23
Version 3.56, 1AOO50K - Critical - Fixed a Flex Systems Manager (FSM) Configuration Patterns problem where configuration deployments would fail with an activation job error message: ERROR: LDAP failed with rc=102 ERROR: LDAP failure: SYSPROF_LDAP_BIND_FAIL INFO
Version 3.55, 1AOO50E - Suggested - Fixed an issue so a fully qualified domain name can be used for a syslog collector in addition to an IP address - Fixed an issue to allow a user the ability to specify the port to use for syslog notifications, rather than only supporting the default port
Version 3.50, 1AOO50B - Suggested - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Initial Release - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.30, 1AOO48L - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.50, 1AOO40Z - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.00, 1AOO40E - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1aoo34z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.30, 1AOO28M - Supports System HS23E, Machine Types: 8038,8039
Version 1.26, 1AOO26N - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Supports System HS23, Machine Types: 7875,1929
Version 1.10, 1AOO24B - Supports System dx360 M4, Machine Types: 7918,7919
Version 1.05, 1AOO10K - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2015. All rights reserved.
ibm_fw_imm2_1aoo68l-5_20_anyos_noarch_chg
LSI 2004 SAS Controller BIOS and Firmware Update for IBM Flex System x440 Compute Node
System Supported: IBM Flex System x440 Compute Node (7917)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 1.20.02 - Moderate Impact/Low Probability of Occurrence --------------- Contains: BIOS Firmware UEFI Driver 07.39.00.00 20.00.05.00 07.27.04.00
Fixes: - Fixed an issue seen with RAID 10 array where during a warm OS boot, certain drive models with a long spin up delay may get marked as failed for being unresponsive. This delay ultimately triggers a rebuild of the array.
Enhancement - Reduce the boot time for UEFI driver for large configurations Fixes: - Fixed an issue that caused the Integrated Management Module (iMM) in System x servers to report Warning: Sensor GPT Status has transitioned from normal to non-critical state. - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Version 9.63, Build ID DSYTE2L o Problem(s) Fixed: 1. 4 Fort diagnostic tests show two sets of the same test
Version 9.63, Build ID DSYTE2K o Problem(s) Fixed: 1. preboot DSA 9.60 and 9.61 both fail CPU Stress Test with abort message 2. ML2 4 Fort diagnostic tests fail in pDSA
Version 9.61, Build ID DSYTE2E o New System Support: IBM System x3850 X6 / x3950 X6 (3837, 3839) o New Operating System support: N/A o Problem(s) Fixed: PMR Number: 00696,656,760 ---- >2TB DSA / Box line quality- any MT - Customer escalation PMR Number: 93660,999,000 ---- 3TB DSA / Box line quality- MT 3837 - Customer escalation o Enhancement: Openssl update to 1.0.1h from 1.0.1g o Limitations: N/A o Special usage: - 2014 Opal Product build
Version 9.60, Build ID DSYTD9S o New System Support: IBM System x3850 X6 / x3950 X6 (3837, 3839) o New Operating System support: N/A o Problem(s) Fixed: N/A o Enhancement: 1. MPx transition of DSA for CPU&Memory Stress Test. 2. Adding InfoCenter Hyperlinks to DSA. o Limitations: 1.After finish run all diagnostics in 25 loop with Emulex 10G options, DSA log will show abnormal, it only record Diags log one time on DSA Diagnostics Completion Log. 2.On GUI, when two ports of the machine want to connect the Extranet at the same time, the machine could not send dsa log to IBM server. you can click test internet connection to solve the problem. 3.CPU & Memory stress test only support for 1 loop. 4.System not show event log item in chassis event log & ipmi event log page when trigger SBE in standalone mode. o Special usage: - 2014 ToolsCenter 14B
Version 9.52, Build ID DSYTD3L o 13D FP hotfix for Openssl update to 1.0.1g from 1.0.1f
Version 9.51, Build ID DSYTD3H o New System Support: IBM System X3850 X6 (3837, 3839) o New Operating System support: N/A o Problem(s) Fixed: N/A o Enhancement: 1. Get standalone memory test results & SOL support for DSAp (for security efi boot) 2. UEFi Secure Boot o Limitations: N/A o Special usage: - 2013 ToolsCenter 13D FP
Version 9.50, Build ID DSYTD1N o New System Support: IBM System X3250 M5 (5458) IBM NeXtScale Node (5455) IBM System x3650 M4 BD (5466)
o Problem(s) Fixed: 1. PMR - 08641,W01,000 Unisys 9BLTCV - 7143 BOMC CD CheckPointPanel Diag test hangs 2. PMR 08699,W01,000 No LSI raw data from DSAp 9.41
o Enhancement: 1. Embedded DSAp Simplification by removing Low-Value Functionality 2. Fusion IO Raw Data Collection 3. pDSA Simplification for FoD Function & GUI Client 4. Remove Tape Diags function for both online & pDSA (Both Embed and Standalone pDSA) 5. Add warning & report in client for nonsupport systems 6. Change sFTP as the default protocol for transfer log to IBM Service o Limitations: 1. For IR controllers, there's no firmware package build version in the LSI controller page.IR controllers includes: (1). ServeRAID H1110 SATA/SAS Controller for System x (2). ServerRaid-Br10il SAS/SATA controller Expansion Card (3). Racine TLA - N2215 SAS/SATA HBA for IBM System x
2. For Software raid(C100,C105) the Fw version& Fw package version are not supported and will display "N/A" in html and blank in text report.
3. IANet_EEPROM diagnostic test record of Powerville(Onboard NIC card of Yongchun) would be inconsistent among the 4 ports in case the ethernet bus was set to ground due to the limitation of Intel CIM Provider. o Special usage: - 2013 ToolsCenter 13D
Version 9.41, Build ID DSYTC1P o New System Support: Flex System x222 Compute Node (7916) IBM System X3650 M4 HD(5460) o Enhancement: N/A o Limitations: 1. As Intel GPU's name is co-processor, DSA will show the name 'Processor' in PCI page's PCI Device table. Please do not mis-understand this item as CPU device. o Special usage: - 2013 ToolsCenter 13C
Version 9.40, Build ID DSYTB7x o Enhancement: 1. Preboot GUI redesign and enhancement--refine GUI into more customer friendly style. 2. FoD Support--FoD key re-activation. 3. pDSA proxy auto-config retrieve. o Limitations: 1. Immv1 embedded pDSA doesn not support any new drivers due to the limited image size. 2. DSA Does not support "VMware ESXi" page report for ESXi 5.x key due to "vmvisor-offline-query" limitaion . o Special usage: - 2013 ToolsCenter 13B
Version 9.30, Build ID DSYTB27 o New System Support: Flex System x440 Compute Node (7917, 2584) IBM System x3300 M4 (7382) o Problem(s) Fixed: 1. PMR - 05766,YL2,760 Aenservice appeared after running UpdateXpress & DSA. 2. PMR - 05193,W01,000 7147 - Intermittent random PSOD in vmware. multiple
o Enhancement: None o Limitations: - FIFO test of NIC diagnostics is not supported on the Intel I350 Quad Port GbE. Powerville has shared FIFO and shared FIFO registers making a test impossible if four ports are running at once. - For more limitations please refer to readme. o Special usage: - 2012 ToolsCenter 12D
Version 9.29, Build ID DSYTAB6 o New System Support: Flex System x440 Compute Node (7917, 2584) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - NGP-4Q(12B+ FixPack3)
Version 9.28, Build ID DSYTAA4 o New System Support: x3630 M4 (7519) x3550 M4 (7383) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - IMMV2 system 2012 4Q-LFC
Version 9.27, Build ID DSYTA7F o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme o Special usage: - IMMv1 system 2012 4Q-LFC
Version 9.26, Build ID DSYTA6G o New System Support: None o Problem(s) Fixed: None o Enhancement: DSA Performance Optimization o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12C
Version 9.21, Build ID DSYTA1U o New System Support: None o Problem(s) Fixed: 1.Recovered LSI Rawdata: "MegaCli -FwTermLog -Dsply -aALL" o Enhancement: None o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B Plus
Version 9.20, Build ID DSYTA0R o New System Support: x3530 M4 (7160) x3630 M4 (7158) x3750 M4 (8722, 8733) HS23E (8038, 8039) Flex System x220 Compute Node (7906, 2585) o Problem(s) Fixed: 1. PMR 05819,YL2,760 An error occured during the execution of DSA on Windows, DSA exits with an error at the eventlog plugin. o Enhancement: 1. Add HW remote presence key collection for High volume systems. o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B
Version 9.07, Build ID DSYT9CA o New System Support: x3750 M4 (8722, 8733) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.06, Build ID DSYT9BC o New System Support: Flex System x220 Compute Node (7906) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.05, Build ID DSYT9AA o New System Support: x3630 M4 (7158) x3530 M4 (7160) x3100 M4 Refresh1 (2582) x3250 M4 Refresh1 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.04, Build ID DSYT99E o New System Support: Flex System x240 Compute Node (8737, 8738, 7863) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.03, Build ID DSYT98I o New System Support: HS23E (8038, 8039) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.02, Build ID DSYT97C o New System Support: iDataPlex dx360 M4 server/2U chassis (7912/7913) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.01, Build ID DSYT96D o New System Support: x3500 M4 (7383) x3550 M4 (7914) x3650 M4 (7915) o Problem(s) Fixed: o Enhancement: None o Limitations: None o Special usage: None
Version 9.00, Build ID DSYT95W o New System Support: BladeCenter HS23 (7875) BladeCenter HX5 (7873, 1910) Flex System x240 Compute Node (8737, 8738, 7863) Flex System Manager Node (8735) x3500 M4 (7383) x3550 M4 (7914) x3630 M4 (7158) x3650 M4 (7915) x3690 X5 (7192, 7147) x3850 X5 / x3950 X5 (7143, 7191) o Problem(s) Fixed: 1. PMR 24817,8QG,000, PMR 30680,499,000 After kicking off DSA on one of the management nodes (x3650 M2) of SONAS 1.2(RHEL5 based), the node became unresponsive and dropped out of the cluster.
2. PMR 53575,000,834, PMR 05961,YL4,760 After running DSA, when using linux dump command on a DDS5 usb internal tape drive attached in x3650M2 backup speed becomes very slowly or failed.
3. PMR 26905,095,866 Running DSA 4.0 as well as DSA 3.4 on x3850 X5 the server is freezing, users have to reboot the server.
4. DSA 4.00 and previous version segmentation fault issue
6. PMR 15086,OTH,760 DSA 9.00 with --no-imm-lan option does not work correctly on RHEL5.3. The USB port state is changed during the execution of DSA.
o Enhancement: 1. Add GUI and CLI menu for Features on Demand (FoD) Activation Key Management o Limitations: Refer to readme. o Special usage: None
Version 4.02, Build ID DSYT92I o New System Support: iDataPlex Direct Water Cooled dx360 M4 server o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 4.01, Build ID DSYT92H o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 4Q lifecycle
Version 4.00, Build ID DSYT91S o New System Support: None o New server options support: None o Problem(s) Fixed: 1. PMR 15065,OTR,760 On Unisys ES7000 or x3850 X5, the Memory Card number with failed DIMM can not be reported in IPMI Eventlog if the Memory Card is bigger than 4.
o Enhancement: 1. Added > 1TB memory test support o Limitations: Refer to readme. o Special usage: - 2011 ToolsCenter 11D
Version 3.48, Build ID DSYT89PUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 3Q lifecycle
Version 3.47, Build ID DSYT89LUS o New System Support: x3100 M4 (2582) x3250 M4 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.46, Build ID DSYT89GUS o New System Support: System x iDataPlex dx360 M3 (6391) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.45, Build ID DSYT89EUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - x3850 X5 / x3950 X5 (7143, 7191) EXA scaling
Version 3.43, Build ID DSYT87HUS o New System Support: BladeCenter HX5 (7873,1910) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.43, Build ID DSYT87FUS o New System Support: x3850 X5 / x3950 X5 (7143, 7191) x3690 X5 (7192, 7147) o Problem(s) Fixed: o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.40, Build ID DSYT85T o New System Support: BladeCenter HS22 (1911) x3650 M3 (5454) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.30, Build ID DSYT80S o New System Support: None o Problem(s) Fixed: None o Enhancement: 1. Correct a problem with LSI MegaRAID reporting for IBM Service o Limitations: Refer to readme. o Special usage: None
Version 3.20, Build ID DSYT75X o New System Support: x3630 M3 (7377) x3690 X5 (7148, 7149) o Problem(s) Fixed: None o Enhancement: 1. Add LSI Hard Disk Drive (HDD) diagnostic back for both the onboard SAS chip and ServeRAID o Limitations: - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Verion 3.20, Build ID DSYT75U o New System Support: x3755 M3 (7164) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Verion 3.10, Build ID DSYT70X o New System Support: x3400 M3(7378, 7379) x3500 M3(7380) x3550 M3 (7944, 4254) x3620 M3 (7376) x3650 M3 (7945, 4255) x3690 X5 (7148, 7149) x3850 X5 Standard Single-node and Multi-node models(7145, 7146) x3950 X5 Specially configured Database Engine models (7145, 7146) iDataplex dx360 M3 (6391) HS22V (7871,1949) HX5 (7872, 1909) o Problem(s) Fixed: None o Enhancement: 1. Added ServeRAID data collection o Limitations: - The following function has been temporarily removed from DSA Preboot for both the onboard SAS chip and ServeRAID: - LSI Hard Disk Drive (HDD) diagnostic - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Version 3.02.56, Build ID DSYT56e o New System Support: None o Problem(s) Fixed: None o Enhancement: - The following systems are supported when BoMC downloads the corresponding system enablement pack: HS22V (7871,1949) x3550 M3 (7944,4254) x3650 M3 (7945,4255) x3400 M3 (7378,7379) x3500 M3 (7839) dx360 M3 (6391) o Limitations: - No HDD diagnostics available - To ensure quality and stability of the DSA code, we have reverted some display functionality of RAID information to what was shown in previous versions of DSA. This affects RAID display on the following adapters: Megaraid 8480 Serveraid MR10i Serveraid MR10is Serveraid MR10m Serveraid MR10k Serveraid M1015 Serveraid M5014 Serveraid M5015 On these adapters, the RAID information is generated from the output of separate command line tools and the format may not match other output in DSA. - For more limitations please refer to readme o Special usage: None
Version 3.00, Build ID: DSYT55a o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7327, 7328, 4251, 4252, 4261 o Limitations: - No HDD diagnostics available - For more limitations please refer to readme o Special usage: None
Version 1.16, Y4YT19AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7839, 7836, 7837 o Limitations: None o Special usage: None
Version 1.15, TMYT20AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7321, 6380, 7323 o Limitations: None o Special usage: None
Version 1.14, D6YT37AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7946, 4198, 7947, 4199 o Limitations: None o Special usage: None
Version 1.13, P9YT48AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7870, 1936, 7809 o Limitations: None o Special usage: None
Version 1.00 - Initial release
(C) Copyright International Business Machines Corporation 2008 - 2012. All rights reserved. ibm_fw_dsa_dsyte2o-9_64_anyos_anycpu_chg
Firmware Update for ServeRAID M5115 PSoC3
Adapters Supported: ServeRAID M5115 SAS/SATA Controller for IBM Flex System (90Y4390)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 70 - Suggested ------------ Firmware version 70 - Added feature to enable ServeRAID M5115 PSoC Agentless data to be visible to xHMC.
Version 69 - Suggested ------------ Firmware version 69 - Fixed issue where CMM Expansion Card VPD FW version does not match IMM Properties for ServeRAID M5115 FW version on x880 X6 system.
Version 68 - Suggested ------------ Firmware version 68 - Fixed issue that inadvertently shuts system off when the PSoC update is initiated. - Added I2C pass-through isolation logic during standby power - Fixed issue that inadvertently surfaces a Mezz fault message after performing a Virtual Reseat. - Added "M5115" signature to I2C 0xB0 register - Added support for RAID Link.
Version 63 - Initial Release ---------- ibm_fw_psoc3_m5115-70_linux_32-64_chg