Integrated Management Module II (IMM2) Firmware Update Change History
Version 3.86, 1AOO56V - Critical - Critical Fix for x3500 M4 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198
Version 3.73, 1AOO56D - Critical Fix for dx360 M4, x3650 M4, x3550 M4, x3500 M4, x3100 M4, x3250 M4, x3750 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.71, 1AOO52W - Critical Fix for x3550 M4: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a problem system may shut down with new Mezz card installed
Version 3.70, 1AOO52Q - Critical Fix: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882)
Version 3.67, 1AOO50G - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.65, 1AOO50D NOTE: If you have a System x3550 M4 with the "Emulex VFA Mezz card" and a ==== single processor, don't update the IMM2 with this firmware - Critical Fix: -- Fixed a problem on the System x3650 M4 server where the system shuts down due to a false temperature event from the ambient temperature sensor - Fixed a problem where the IMM2 may erroneously report a fan fault in the x3630 M4 when the system is powering on. See RETAIN tip H207461 for the description of the original problem - Fixed a screen refresh problem where it occurs after resetting IMM2 - Fixed a firmware problem that may cause the IMM2 to reset unexpectedly - Fixed a problem where the IMM2 SNMP interface may intermittently be unavailable if the system is running VMWARE ESXi 5.x - Fixed a problem where the CPU may potentially throttle in the x3650 M4 system with two 550 watt power supplies and one hard drive backplane
Version 3.60, 1AOO50C - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM
Version 3.56, 1AOO50K - Fixed a Flex Systems Manager (FSM) Configuration Patterns problem where configuration deployments would fail with an activation job error message: ERROR: LDAP failed with rc=102 ERROR: LDAP failure: SYSPROF_LDAP_BIND_FAIL INFO
Version 3.55, 1AOO50E - Fixed an issue so a fully qualified domain name can be used for a syslog collector in addition to an IP address - Fixed an issue to allow a user the ability to specify the port to use for syslog notifications, rather than only supporting the default port
Version 3.50, 1AOO50B - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.35, 1AOO48N - Critical Fix: -- Corrected a problem on the System x3650 M4 and x3650 M4 HD servers causing the system to shut down due to an erroneous critical temperature event reported by the ambient temperature sensor
Version 3.30, 1AOO48L - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.60, 1AOO42Y NOTE: For increased security, only high strength ciphers are now supported when using https.
==== Your browser must support one of the following cipher suites: | HE-RSA-AES256-SHA256 TLSv1.2 Kx=DH Au=RSA Enc=AES(256) Mac=SHA256 DHE-RSA-AES256-SHA SSLv3 Kx=DH Au=RSA Enc=AES(256) Mac=SHA1 AES256-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA256 AES256-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA1 DHE-RSA-AES128-SHA25 TLSv1.2 Kx=DH Au=RSA Enc=AES(128) Mac=SHA256 DHE-RSA-AES128-SHA SSLv3 Kx=DH Au=RSA Enc=AES(128) Mac=SHA1 AES128-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA256 AES128-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA1
- Added support for the IBM Flex System x222 Compute Node - Improved Remote Presence (keyboard, mouse and virtual media)and in-band management (LAN-over-USB) performance - Changed the default file name for the Service Data file (First Failure Data Capture or FFDC) on the web interface to incorporate the machine type, serial number and a timestamp - Updated the IMM2 PCIe Bridge Firmware to support Windows 2012 Certification - Improved IMM2 Reliability, Availability, Serviceability (RAS) Features: - Added component and system VPD integrity checking & reporting - Enhanced Service Data collection (FFDC)
- Enhanced the configuration of UEFI settings via the CIM interface for applications like IBM Systems Director - Added Sub-manufacturer inventory support for mezz card and Sub-manufacturer inventory support for the system for IBM Systems Director - Added the UUID for the PCIe Expansion Node and the Storage Expansion Node to the SLP attributes reported by the IMM2 - Added the number of enabled CPU core and the Static power savings mode support for IBM Systems Director - Enhanced the alert recipient email notification, firmware update, event log, log out, and hardware information web pages to improve usability - Added support for IPMI & SNMPv3 accounts to be centrally managed by the Flex Chassis Management Module - Fixed a problem where an invalid configuration was erroneously reported for an unpopulated CPU socket in the IBM Flex System x440 - Enabled users to configure a longer trespass message - Increased the length of the LDAP group filter field to 511 characters - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems energy pack monitoring - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems LED management - Added IPMI command to configure the LAN-over-USB IP address
Version 2.52, 1AOO42E - Critical Fix: -- Fixed a problem on the System x3300 M4 servers causing the system to shut down due to a critical temperature event reported by the ambient temperature sensor
Version 2.50, 1AOO40Z - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.06, 1AOO42B - Corrected the firmware to prevent users from disabling the IPv6 interface - Fixed a problem that caused the IMM2 to reset itself after running for a period of time - Corrected the SNMP request to disable the IMM2 IPv4 interface so that it disables only IPV4, instead of both IPv4 and IPv6 - Fixed a problem that occasionally caused the server to shut down when the IMM2 is reset - Fixed a problem where the IMM2 incorrectly reported a battery voltage error - Corrected a problem where repeated frequent IMM2 resets causes the IMM2 to run the firmware in its backup partition - Corrected a problem report where the IMM2 did not report a failure to the system profiles script when the chassis UUID is unavailable
Version 2.00, 1AOO40E - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1aoo34z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.30, 1AOO28M - Supports System HS23E, Machine Types: 8038,8039
Version 1.26, 1AOO26N - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Supports System HS23, Machine Types: 7875,1929
Version 1.10, 1AOO24B - Supports System dx360 M4, Machine Types: 7918,7919
Version 1.05, 1AOO10K - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved.
ibm_fw_imm2_1aoo56v-3_86_anyos_noarch_chg
BIOS/FW/UEFI Update for ServeRAID H1110 SAS/SATA Controller for IBM System x
Controller Supported: ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492)
Enhancement - Reduce the boot time for UEFI driver for large configurations Fixes: - Fixed an issue that caused the Integrated Management Module (iMM) in System x servers to report Warning: Sensor GPT Status has transitioned from normal to non-critical state. - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
Integrated Management Module II (IMM2) Firmware Update Change History
Version 4.31, 1AOO58T - Critical - Critical Fix for x3650M4, x3550M4, x3500M4, dx360M4, x3100 M4, x3250m4, x3750M4, x3650M4 HD, x3630M4, x3530M4, x3300M4, x3250M5 -- Updated the firmware with patches to address the OpenSSL vulnerabilities listed in CVE-2014-0224, CVE-2014-0221, CVE-2014-0195, CVE-2014-3470, CVE-2010-5298, CVE-2014-0198 - Added option to export the certificate signing request in PEM format - Various Remote Presence enhancements including: -- Support for a MAC OS-x client -- Scaled video viewer window -- ASU set up of Remote Presence hot keys -- Virtual media mounting via URL - Removed potentially sensitive information from the service data file - Fixed a problem on x3650 M4, x3550 M4, x3500 M4, x3650 M4 HD where the IMM2 may not detect a loss of power supply redundancy - Fixed a problem where the LDAP group filter does not support a full DN - Fixed a problem where the syslog alert fields "Msg Type" and "Severity" did not follow RFC 5424 - Fixed a problem where the IMM2 only supported the default network port for syslog notifications - Fixed a problem where the SNMP "sysName" query always returns the string "SNMP Service" instead of the system name - Fixed a problem where the Global Login Settings changes were lost after an IMM2 restart
Important: Before you flash the IMM2 firmware back to version 3.82 or older, set the IMM2 Security option to use the Basic Compatibility Mode. This will prevent a possible loss of access to the IMM2.
Version 4.15, 1AOO58K - Suggested - Added support for the BIE (Blade IO Expansion Board) on the HS23, HS23E - Fixed a problem that prevented the AMM from controlling power when local power control is disabled on the HS23, HS23E
Version 3.91, 1AOO58G - Critical - Supports System x3750 M4, Machine Type: 8752, 8718 - Add a feature to allow users to block power control from the power button on the x3750M4
Version 3.73, 1AOO56D - Critical - Critical Fix for dx360 M4, x3650 M4, x3550 M4, x3500 M4, x3100 M4, x3250 M4, x3750 M4 -- Updated the firmware with patches to address the 'Heartbleed' OpenSSL bug (CVE-2014-0160)
Version 3.71, 1AOO52W - Critical - Critical Fix for x3550 M4: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a problem system may shut down with new Mezz card installed
Version 3.70, 1AOO52Q - Critical - Critical Fix: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882)
Version 3.67, 1AOO50G - Initial Release - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.65, 1AOO50D - Suggested NOTE: If you have a System x3550 M4 with the "Emulex VFA Mezz card" and a ==== single processor, don't update the IMM2 with this firmware - Critical Fix: -- Fixed a problem on the System x3650 M4 server where the system shuts down due to a false temperature event from the ambient temperature sensor - Fixed a problem where the IMM2 may erroneously report a fan fault in the x3630 M4 when the system is powering on. See RETAIN tip H207461 for the description of the original problem - Fixed a screen refresh problem where it occurs after resetting IMM2 - Fixed a firmware problem that may cause the IMM2 to reset unexpectedly - Fixed a problem where the IMM2 SNMP interface may intermittently be unavailable if the system is running VMWARE ESXi 5.x - Fixed a problem where the CPU may potentially throttle in the x3650 M4 system with two 550 watt power supplies and one hard drive backplane
Version 3.60, 1AOO50C - Suggested - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM - Corrected a problem that caused the IMM to report an "Unsupported blade/blower combination" error on HS23
Version 3.56, 1AOO50K - Critical - Fixed a Flex Systems Manager (FSM) Configuration Patterns problem where configuration deployments would fail with an activation job error message: ERROR: LDAP failed with rc=102 ERROR: LDAP failure: SYSPROF_LDAP_BIND_FAIL INFO
Version 3.55, 1AOO50E - Suggested - Fixed an issue so a fully qualified domain name can be used for a syslog collector in addition to an IP address - Fixed an issue to allow a user the ability to specify the port to use for syslog notifications, rather than only supporting the default port
Version 3.50, 1AOO50B - Suggested - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Initial Release - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Suggested - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Critical - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.35, 1AOO48N - Critical - Critical Fix: -- Corrected a problem on the System x3650 M4 and x3650 M4 HD servers causing the system to shut down due to an erroneous critical temperature event reported by the ambient temperature sensor
Version 3.30, 1AOO48L - NonCritical - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Initial Release - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - NonCritical - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.60, 1AOO42Y - NonCritical NOTE: For increased security, only high strength ciphers are now supported when using https.
==== Your browser must support one of the following cipher suites: | HE-RSA-AES256-SHA256 TLSv1.2 Kx=DH Au=RSA Enc=AES(256) Mac=SHA256 DHE-RSA-AES256-SHA SSLv3 Kx=DH Au=RSA Enc=AES(256) Mac=SHA1 AES256-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA256 AES256-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA1 DHE-RSA-AES128-SHA25 TLSv1.2 Kx=DH Au=RSA Enc=AES(128) Mac=SHA256 DHE-RSA-AES128-SHA SSLv3 Kx=DH Au=RSA Enc=AES(128) Mac=SHA1 AES128-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA256 AES128-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA1
- Added support for the IBM Flex System x222 Compute Node - Improved Remote Presence (keyboard, mouse and virtual media)and in-band management (LAN-over-USB) performance - Changed the default file name for the Service Data file (First Failure Data Capture or FFDC) on the web interface to incorporate the machine type, serial number and a timestamp - Updated the IMM2 PCIe Bridge Firmware to support Windows 2012 Certification - Improved IMM2 Reliability, Availability, Serviceability (RAS) Features: - Added component and system VPD integrity checking & reporting - Enhanced Service Data collection (FFDC)
- Enhanced the configuration of UEFI settings via the CIM interface for applications like IBM Systems Director - Added Sub-manufacturer inventory support for mezz card and Sub-manufacturer inventory support for the system for IBM Systems Director - Added the UUID for the PCIe Expansion Node and the Storage Expansion Node to the SLP attributes reported by the IMM2 - Added the number of enabled CPU core and the Static power savings mode support for IBM Systems Director - Enhanced the alert recipient email notification, firmware update, event log, log out, and hardware information web pages to improve usability - Added support for IPMI & SNMPv3 accounts to be centrally managed by the Flex Chassis Management Module - Fixed a problem where an invalid configuration was erroneously reported for an unpopulated CPU socket in the IBM Flex System x440 - Enabled users to configure a longer trespass message - Increased the length of the LDAP group filter field to 511 characters - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems energy pack monitoring - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems LED management - Added IPMI command to configure the LAN-over-USB IP address
Version 2.52, 1AOO42E - Critical - Critical Fix: -- Fixed a problem on the System x3300 M4 servers causing the system to shut down due to a critical temperature event reported by the ambient temperature sensor
Version 2.50, 1AOO40Z - Suggested - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.06, 1AOO42B - Critical - Corrected the firmware to prevent users from disabling the IPv6 interface - Fixed a problem that caused the IMM2 to reset itself after running for a period of time - Corrected the SNMP request to disable the IMM2 IPv4 interface so that it disables only IPV4, instead of both IPv4 and IPv6 - Fixed a problem that occasionally caused the server to shut down when the IMM2 is reset - Fixed a problem where the IMM2 incorrectly reported a battery voltage error - Corrected a problem where repeated frequent IMM2 resets causes the IMM2 to run the firmware in its backup partition - Corrected a problem report where the IMM2 did not report a failure to the system profiles script when the chassis UUID is unavailable
Version 2.00, 1AOO40E - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1aoo34z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Suggested - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Suggested - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Suggested - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Critical - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Suggested - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Suggested - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Suggested - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Initial Release - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Critical - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Suggested - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Critical - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Suggested - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - NonCritical - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Initial Release - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Initial Release - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Initial Release - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Initial Release - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Critical - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.30, 1AOO28M - Supports System HS23E, Machine Types: 8038,8039
Version 1.26, 1AOO26N - Initial Release - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Initial Release - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Suggested - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Initial Release - Supports System HS23, Machine Types: 7875,1929
Version 1.10, 1AOO24B - Supports System dx360 M4, Machine Types: 7918,7919
Version 1.05, 1AOO10K - Initial Release - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved.
Firmware Version: 2.82x6 (w/ 5.12a13 Universal Boot Code) (Supported for IBM System x & BladeCenter)
Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM (BOFM) - Emulex FC configuration utility is in the wrong F1 setup screen
- Multiple adapters connected to same PCIe bridge port can request more I/O space than system can allocate. - Updated firmware kernel code so Saturn based HBA and mezz cards do not use or advertize need for system I/O Space.
Enhancement - Reduce the boot time for UEFI driver for large configurations Fixes: - Fixed an issue that caused the Integrated Management Module (iMM) in System x servers to report Warning: Sensor GPT Status has transitioned from normal to non-critical state. - Fixed an issue where 4k sector size drives with 512e reporting enabled show wrong physical size when running a read capacity 16 command. - Fixed an issue where speed negotiation for 3Gig SATA drives is not handled properly. - Added Support for Report Luns Command - Fixed an issue where OS hang during install of Linux system to a SSD - Fixed an issue where SAS device page 0 may still be present for Initiator devices that have been removed from the topology. - Fixed an issue where RHEL 6.3 hangs during boot with IBM 600GB High IOPS MLC Modular Adapter - Fixed an issue where a non-PI volume made up of all PI capable drives, may come up as PI enabled after a controller reset. - Fixed an issue where a fault 0X8808 occurs when a reset is issued to the controller that has max number of active/inactive volumes - Fixed an issue where "Device Present" Flag of SAS device page0 is not set for initiator controller in then target controller when two controllers are connected to each other in initiator/target mode. - Fixed an issue where extended tags and PCIe upconfigure capability are disabled in SAS2208 and SAS2308. - Fixed an issue where force full discovery does not trigger rediscovery of an expander after the initial expander discovery fails. - Fixed an issue where single RAID0 volume activation was succeeding, even though controller does not support single drive RAID0. - Fixed an issue where RAID1 volume of Non-PI drives moves to optimal state when a PI drive is hotplugged and 'Enable PI mixing' not enabled. - Fixed an issue where Locate LED's stop automatically after 3-4 minutes before user issues command to turn off the Locate LED's. - Fixed an issue where fault 0x8618 is seen when a new volume is created in the presence of another volume which is undergoing resync along with IO. - Fixed an issue background initialization does not start on RAID0 volume with PI drives, after removing and reinserting a volume member.
BIOS - Fixed an issue where core BIOS displays warning message when it fails to add all of the drives connected to int13 chain, then waits for user to press any key to continue further, rather than continuing after 3 seconds. - Fixed an issue where incorrect adapter is being tagged as the first adapter found. - Fixed an issue where the save or discard changes prompt appears after a failed attempt to set volume as the boot device in BIOS CU. - Fixed an issue where BIOS CU provides incorrect device pointer when checking for raid disk to allow/disallow setting boot device. - Fixed an issue where device properties screen is invoked from a direct attach device using Alt+D in SAS topology screen, device traversing [Alt+N & Alt+P] is restricted within the direct attach device and expander attach devices are not traversed. - Fixed an issue where the drive status field does not show 'Max dsks' when trying to select 11th drive for RAID10 volume. - Fixed an issue maximum Int13 devices settings does not get honored, when the value is set as 0 in BIOS CU - Fixed an issue where drive size of 1.088GiB was showing as 1.880GiB. - Fixed an issue current boot device set to device at slot 4" message Not displaying for Adaptors with boot order other than 0. - Fixed an issue where the BIOS CU navigates to create new volume screen instead of back to raid properties screen. - Fixed an issue where BIOS banner showed 'FF' for slot information. - Fixed an issue where the drive's SMART status is always shown as no irrespective of drive's SMART status, under Pred Fail column of the manage hot spare screen and create new volume screen. - Fixed an issue where SAS2 BIOS: volume size shows inconsistent value in the create new volume' screen after selecting the last volume member. - Fixed an issue where a disabled adapter causes the second adapter status to show as unavailable even though the second adapter is enabled. Uefi Enhancement 1/2 - Added capability to create an IR RAID volume in non-PI mode, even when all member drives are PI Capable. - Added PI info and ability to control creation of PI Volume in UCM of BSD HII. - Added new form manage PHY settings to support enabling or disabling of a controller PH Fixes: - Fixed an issue view foreign volume option is disabled with a foreign volume in the configuration.
- Fixed issue where acceptable indistro device drivers may not pass minium driver check. BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal. - Fixed issue where update will not install with the 09.101 megaraid_sas device driver.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
IBM HBA/LSI Onboard 6Gb SAS/SATA/SSD Driver for Linux
NOTE TO SERVICE - Reference RETAIN N/A
Supported Controllers: - IBM N2125 SAS/SATA Controller (46C9011) - IBM N2115 SAS/SATA Controller (46C8989) - IBM 300 GB High IOPS MLC Modular Adapter (90Y4361) - IBM 600 GB High IOPS MLC Modular Adapter (90Y4365) - IBM 800 GB High IOPS MLC Modular Adapter (90Y4369) - IBM 300 GB High IOPS SLC Modular Adapter (90Y4373) - ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492) - IBM 6Gb SAS HBA (46M0907) - IBM 6Gb SSD HBA (68Y7362) - Onboard LSI 2004 SAS
Version 18.00.01.00 - Suggested ------------------ Enhancement: - Added support for SLES 11 SP 3. - Turn off the Predictive Failure LED when a drive is removed. - Added support to issue a Start Stop Unit command (stopping the target) to all non-IR direct-access SATA devices before the driver is shut down or unloaded.
Fixes: - Fixed an issue where the driver message logs contains an entry "mpt2sas0: _base_get_ioc_facts: failed going to ready state, when the controller is in operational state. - Fixed an issue where a kernel panic observed after issuing controller diagnostic reset. - Fixed an issue where a kernel panic observed when an enclosure is removed load while the driver module is loading. - Fixed and issue where component drives of a volume go missing once the volume is deleted. - Fixed and issue where the mapping of reply queues used for IO requests coming from each CPU is not balanced when number of CPU cores are greater than the number of MSI-X vectors. - Fixed and issue where the set_affinity.sh script fails on the systems having more than 32 CPU cores. - Fixed an issue where device entries are removed when async scanning mode is enabled and device scanning is in progress. Version 15.00.00.00 - Suggested ------------------ Enhancements: - Added support for SLES 11 SP 2 - Added support for N2115/N2125 SAS/SATA, 300GB MLC (90Y4362), 600GB MLC (90Y4366), 800GB MLC (90Y4370) and 300GB SLC (90Y4374)
Fixes: - Fixed issue where the phy disks are not discovered when the volume members are hot removed, and added while performing diag reset. - Fixed issue where SAS HBA 6Gb adapters fails Read Capacity 16 command sent to Tape drives. - Fixed issue where a device scan following a host reset could get stuck in an infinite loop. - Fixed issue where driver goes into a infinite loop when the REPORT_LUNS command gets a check condition. - Fixed issue where driver does not comply with the updated timing requirements for issuing a Hard Reset. - Fixed issue where missing delay was not getting set during system boot-up kernels 2.6.20 and newer.
Version 10.30.00.00 - Suggested ------------------ Fixes: - Use a different method for blocking IO request from SCSI Mid Layer when using the SysFS shost attribute called task_management. - Fixed issue to not allow IOCTLS to be processed when tge device driver is loading, which could cause a kernel panic. - Added support in asynchronous scanning logic to handle faults during discovery when loading the driver. - Allocate only one msix vector for the controllers that do not support multi-reply queues and NUMA IO. - Added per lun delete flag to addres an issue where a cable is removed and added back within the DMD timer expired timeout. - Fixed issue with reading raid configuration information for inactive volumes - Fixed issue where a Stack trace seen in message log after cable pull and host reset. - Fixed issue where The configuration pages are failing if raid volume is configured while issuing a host reset - Fixed issue where the Devices are not removed after "cable pull". - Fixed issue when devices are behind two deep cascaded expanders, they don't get added if the "cable add" is done while host reset is active. - Fixed a failure message displayed in the log messages during host reset while removing devices - Fixed issue where drives are not getting removed when the enclosure cable is pulled out from the expander and Port Reset is issued. - Fixed issue where the Chip Resets results in repeated timeouts. - Fixed issue with expanders where a hang occurs when there is smart error.
Version 4.30.01.00 - Initial release ------------------ ibm_dd_mpt2sas_18_00_01_00_sles11_32-64_chg
=============================================================================== Emulex NIC Device Driver for Linux ===============================================================================
Device Driver Version: 10.2.377.26 Supported On: System x and Bladecenter
Device Driver Version: 10.2.363.0 Supported On: System x and BladeCenter
Problems Fixed: - Multiple performance improvements in virtualized environments (SR-IOV,UMC) - Resetting Transparent Vlan to Default Vlan is not working - Cleanup ethtool set settings code - ARI on IBM x3650M4: All functions are not displayed in Linux
Device Driver Version: 10.2.261.0 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Provide link state control for VFs - ethtool shows port as fibre though copper cable is connected. - Multi channel config should be determined via port resource descriptor - Showing WoL supported in ethtool for BE3 where it is not supported - be2net driver crash when umc enabled - ip link show command shows vlan for vfs although vlan creation is failed on the vfs - Emulex be2net driver does not support IOMMU pass through mode
Device Driver Version: 10.0.800.0 Supported On: IBM System x
Problems Fixed: - Low bi-di throughput seen on 1g ports of HS-23 LOM - Multiple performance improvements - Bonding driver takes approx 20 seconds to be ready
Incremental Interoperability: - RHEL 5.10 - RHEL 6.5 - XE-102 and XE-104 ASIC (OCx14xxx) - Support for set and get channels ethtool operation
Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.4 and above 64-bit with KVM * SLES11 SP3 and above 64-bit with KVM
NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest.
Device Driver Version: 4.6.267.4 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV configuration section of the Linux NIC Driver Documentation has been modified to improve clarity
Incremental Interoperability: - S3 Resume on IBM Flex - SLES 11.3 on IBM System x and BladeCenter
Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.3 and 6.4 64-bit with KVM * SLES11 SP2 and SP3 64-bit with KVM
NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest.
- Use of SR-IOV with the XEN hypervisor is not supported at this time.
- Use of SR-IOV with the KVM hypervisor requires the use of macvlan network interfaces.
Device Driver Version: 4.6.148.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - Ethernet performance issues in a variety of workloads - VFs are not displayed after driver re-load when is VFs attached to VM - vLAN tagging in Switch Agnostic vNIC mode
Incremental Interoperability: - RHEL 5.9 - RHEL 6.4 - Network performance varies with workload. An ethernet driver tuning script and instructions is now included with the be2net driver. - Switch Independent Mode within hypervisor OS's
Known Issues: - Multi-channel is not supported in RHEL5.x XEN. This is a kernel limitation - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV is not supported with RHEL5.x XEN
Device Driver Version: 4.4.180.0 Supported On: IBM Flex
Device Driver Version: 4.2.389.0 Supported On IBM System x and BladeCenter
Problems Fixed: - Unloading the driver hangs the system after running IPv6 traffic - Link status messages cleaned up when in Switch Agnostic mode - Miscellaneous network performance issues to improve throughput - Miscellaneous problems related to SRIOV to improve usability - Ethtool wol command displays wol enabled even when disabled - Ethtool speed reported as 10000Mb/s for disabled devices in Switch Agnostic mode
Incremental Interoperability: - RHEL6.3 GA Kernel - Increase default B/W for SRIOV vf's to 10Gb from 100Mb
Device Driver Version: 4.1.413.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - WOL changes for Linux NIC driver as mentioned in Bug# 24543 - SR IOV UE when attempt to do multiple (3 times) driver load/unload - Speed is 10000Mb/s for Disabled devices in UMC Mode - Incorrect Duplex value is shown for unconnected port of NC552m in Rhel6.1 32bit - SLES 11 SP2 GMC: Enable support for Lnx NIC Driver - SRIOV: When VGT is configured for a VF, ip link show doesn't display it for the VF configured. - RHEL 5.8 GA: Enable support for Lnx NIC Driver - ip link command with vlan = 4095 has toggling effect - ip link command with vlan =0 should remove guest VGT privilege
Device Driver Version: 4.1.334.39 Supported On: IBM System x and BladeCenter
Problems Fixed: - SR-IOV: Can't load be2net driver in a VM after the VM has been rebooted - SR-IOV: Unload PF driver with VF driver loaded causes system instability - SR-IOV: VF MAC always gets Emulex OUI - SR-IOV: Partition the limited per port VLAN entries across VFs and PFs - Non Member VLAN packets not received in interface promiscuous mode in BE3 - Avoid CQ full condition in HW - be2net: use RX_FILTER cmd to program multicast addresses - account for skb allocation failures in ethtool stats - Support 60 second delay to Linux NIC driver to allow FAT dump completion on recovery from EEH - Link status is up [ethtool and OCM] when the bandwidth is assign 0 for UMC configuration - Remove msix module parameter - Use V1 version of COMMON_NTWK_LINK_STATUS_QUERY for Lancer. - Emulex: Ethtool failing to update FW - Emulex: Panic in be2net driver in SLES11-SP2-B7 on adapter - TCP ACKs from different connections are getting received in single queue - Multicast filtering feature not working on PPC - Exit of mcast promiscous mode not working - VLAN promiscous mode cannot be set on Lancer - Can't communicate after changing MAC address via VLAN interface - Improper memory accounting in received packets - WOL changes for Linux NIC driver as mentioned in bug - Transparent VLAN tagging feature not working in SR-IOV
Please visit www.qlogic.com for full documentation, additional drivers, and management applications.
Version 3.2.5.1 New Features and Feature Enhancement: - References to Brocade changed to QLogic - Support for RHEL5.11 and RHEL7.0
Version 3.2.4.0 New Features and Feature Enhancement: - Support for RHEL5.10 and RHEL6.5
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
Version 3.2.0.0 New Features and Feature Enhancement: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Fixes and Enhancements: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Version 3.1.0.0 Key features and enhancements supported for the software release 3.1.0.0 include the following:
New Features: - D-port support between Brocade 16Gb HBAs and Brocade 16Gb FC switch platforms with FOS v7.0.1 and later releases - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage - Performance enhancements in Ethernet drivers - Technology Preview support of 1860 HBA on Power PC architecture
Fixes or Enhancements: - Resolved an issue where HCM Agent may not start if BR1860 adapter is configured in NIC mode. - Improved stability with Hyper-V and Teaming configurations. - Resolved I/O errors when running traffic with Brocade HBAs(models 415, 425, 815, 825, and 804), if the server’s PCI max read request size is configured to be 2K or greater with PCI Gen2x8.
Version 3.0.0.0 Fixes and Enhancements: - Added support for Brocade 1860 AnyIO Fabric Adapter (User configurable port mode - FC or NIC or CNA) - Added Fibre Channel 16G Support - Enabled Fabric Assigned Address in Fibre Channel Fabric - Added PF based Virtualization – vHBA - Enhanced CLI, HCM GUI and CIM support in inbox drivers. - Added PF based Virtualization - vNIC - Added iSCSI over DCB Support - Added Multiple Tx Priority Queues Support - Added SNMP Support
Version 2.3.0.3 Fixes and Enhancements: - Enhanced SNIA API to report port speed of 4 and 8Gbps in SNIA format. - Enhanced XIV array interoperability that addresses a data integrity corner case. - Enhanced the transmit path handling in Linux Network Driver to avoid a corner case that could lead to transmit path stall. - Enhanced the Linux Adapter Software installer script to update the initrd with the correct name even when there are multiple copies of the OEM specific initrd(s).
Version 2.3.0.0 Enhancements: - Enabled HP DL120 server to support Boot over SAN with two Brocade HBAs installed. - Improved network driver CPU and performance optimization. - Enabled automated target and LUN discovery of enterprise HDS storage once LUN masking has occurred. - Improved Tivoli interoperability to meet device display requirements.
Version 2.2.0.1 Added capability to handle ADISC frames. Unhandled ADISC use can cause SAN boot failure when booting from IBM storage array.
Version 2.2.0.0 Adds support for bootcode updates to Bladecenter 10G Converged Network Adapters
Version 2.1.0.0 Adds support for bootcode updates to 10G Converged Network Adapters
Version 2.0.0.0 Initial release for 4/8G FC HBAs brcd_dd_nic_bna-3_2_5_1_sles11_32-64_chg
======================================================= Change History for Qlogic Linux iSCSI driver for 10 GbE Converged/Intelligent Ethernet Adapter ======================================================= Document Name: Change History Document Status: IBM General Avalibility Latest Package Version: 5.4.1.9 Latest Driver Version: 5.04.01.09 Document Updated: 09/25/2014 Product: Qlogic iSCSI Linux Device Driver
Defect/Enhancement: Defect Problem: Adapter initialization failure during driver load time Solution: The get_sys_info mailbox command was changed in firmware that caused the mailbox command to fail thus failing the adapter initialization. Added fix to handle the get_sys_info mailbox command to validate the size of data returned in the mailbox command response. Introduced: Firmware v5.02.04 Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Defect Problem: Driver module parameter ql4xdontresethba=2 does not allow context resets [ER00000000100932] Solution: Added fix to set the DONTRESET_BIT0, in case ql4xdontresethba==2. Also changed the ql4xdontresethba description, if parameter value is set to 1. Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Different activities are performed on link events while loopback diagnostics is in progress Solution: Fix is to quiesce all driver activities like re-login to devices, dynamic lun scan, iSNS checks etc. while loopback diagnostics is in progress. Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Loopback mode request on same physical port from same or other protocol drivers must not be permitted Solution: Added fix to invalidate loopback request on same physical port Introduced: Day One Impact: HW: ISP8032 OS: RHEL 5.6/5.7/5.8, RHEL 6.0, RHEL 6.1, Citrix 5.6 FP1, Citrix 6.0, SLES 11 SP1, SLES 10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Failure of restoration of loopback port configuration to original configuration Solution: If restoring of original port configuration fails then reset the chip. Failure to do so may not restore the link state and other driver instances sharing the physical port would be left in a non-operational state. Introduced: Day One Impact: HW: ISP8032 OS: RHEL 5.6/5.7/5.8, RHEL 6.0, RHEL 6.1, Citrix 5.6 FP1, Citrix 6.0, SLES 11 SP1, SLES 10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: ISP4xx and ISP82xx firmware may assert if given more IOCBs than it can handle Solution: The driver was updated to throttle the number of active IOCBs based on the total # of IOCB buffers received from GetFirmwareStatus mbx_sts[2]. Introduced: Day One Impact: HW: ISP4xxx/ISP82xx OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Defect Problem: Failure to re-register IRQ handlers while retrying of adapter initialization Solution: Added fix to re-register the interrupt handler when adapter initialization is retried. Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Driver unable to collect forceful firmware dump [ER0000000097083] Solution: Added support to forcefully collect firmware dump using command, "echo 2 > /sys/class/scsi_host/hostX/device/fw_dump" For ISP83xx case, check if ISP83xx can perform reset before setting reset owner and firmware hang flags. Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: All supported Linux flavors Protocol: iSCSI
v5.03.01.07.xx.xx-x0 ---------------------
Defect/Enhancement: Defect Problem: Minidump collected using QLogic application gives warning messages when verified using minidump verification tool Solution: Added fix to return the total minidump size to the application and sync the coredump data structure with the application data structure. Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: RHEL 5.6/5.7/5.8, RHEL 6.0, RHEL 6.1, Citrix 5.6 FP1, Citrix 6.0, SLES 11 SP1, SLES 10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Defect Problem: Compilation warnings were seen on SLES 10 32-bit arch Solution: Fixed compilation warnings of 32-bit kernel flavors Introduced: Day One Impact: HW: All supported Hardware OS: SLES 10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Unknown AENs were seen in log messages Solution: Added debug statements to print the received AENs instead of unknown AENs Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Defect Problem: System panic was seen while collecting Minidump using QLogic application Solution: Added fix to collect minidump specific to ISP83xx instead of older method used for ISP40xx. Introduced: Day One Impact: HW: ISP8032 OS: RHEL 5.6/5.7/5.8 Protocol: iSCSI
v5.03.01.06.xx.xx-x0 ---------------------
Defect/Enhancement: Defect Problem: Mailbox command timeout seen just after completion of adapter reset Solution: Added fix to enable mailbox/AEN interrupts before initializing the firmware to make sure mailbox/AEN interrupts are processed in interrupt mode. Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Kernel panic while driver is trying relogin to targets after completion of adapter resets Solution: Added fix to handle stale DDB entries after reinitialization of DDB list and 8014 AENs for new devices. Introduced: Day One Impact: HW: All supported Hardware OS: RHEL 5.6/5.7/5.8, RHEL 6.0, RHEL 6.1, Citrix 5.6 FP1, Citrix 6.0, SLES 11 SP1 Protocol: iSCSI
Defect/Enhancement: Defect Problem: Target scan took longer time when driver loaded in legacy interrupt mode Solution: Added fix to complete the scsi command as early as possible from the legacy interrupt handler context instead of waiting for completion from the DPC context Introduced: Day One Impact: HW: ISP8032 OS: SLES10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Defect Problem: Adapter reset seen for ACB old state as VALID and new state as ACQUIRING Solution: Added fix to perform context reset instead of adapter reset for ACB states ACB_STATE_VALID and ACB_STATE_ACQUIRING Introduced: Day One Impact: HW: ISP8032 OS: RHEL 5.6/5.7/5.8, RHEL 6.2, SLES 11 SP2, SLES 10 SP3/SP4 Protocol: iSCSI
Defect/Enhancement: Defect Problem: Retries for initialize adapter seen if driver probe failure encountered due to mailbox timeout Solution: Added fix to clear AF_IRQ_ATTACHED and fail probe adapter if initialize adapter fails and thus avoid multiple reties of initialize adapter. Introduced: Day One Impact: HW: ISP8032 OS: RHEL 5.6/5.7/5.8 Protocol: iSCSI
Defect/Enhancement: Defect Problem: IPv6 targets do not come back online after cable pulls (LINK DOWN/UP) Solution: Set options field of ddb_entry struct to identify IPv6 target. After driver DDB allocation, options field of ddb_entry struct was not populated. So IPv6 targets behaved like IPv4 targets and issued relogin on IPv4 targets instead of IPv6 targets. Set options field of ddb_entry struct to identify IPv6 target. Introduced: Day One Impact: HW: All supported Hardware. OS: RHEL 5.6/5.7/5.8 Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Pause flood causes switch port to disable Solution: Added Disable Pause Frame support Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: Udev fw_dump file nomenclature mismatch across multiple protocols Solution: Use standard nomenclature for udev fw_dump file Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Defect Problem: Mailbox command timeouts seen intermittently Solution: Fix double clearing of RISC interrupt in polling mode Introduced: Day One Impact: HW: ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Enhancement Problem: IDC lock recovery in PCIe AER error recovery path Solution: Fix recursive IDC locking in PCIe AER recovery path Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: All supported Linux flavors Protocol: iSCSI
Defect/Enhancement: Defect Problem: Firmware relogin failure on adapter reset causes IOs to halt Solution: Retrieve the firmware device state to check if relogin is necessary Introduced: Day One Impact: HW: ISP8022/ISP8032 OS: RHEL 5.6/5.7/5.8 Protocol: iSCSI
Version 5.03.01.05 Initial release of Qlogic iSCSI Device Driver for 10 Gb Adapter.
qlgc_dd_iscsi_qla4xxx-5_04_01_09_sles11_32-64_chg
uEFI Flash Update Version 1.82 (BuildID D7E146C) Change History
Version 1.82 - BuildID: D7E146C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Turn off High Precision Event Timer (HPET) from uEFI setting. - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570
Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.71 - BuildID: D7E142A ------------------------------------------------- Problem(s) Fixed: - Fixed an issue with continuous reboots when applied new LSI FW and the Remote Console setting is Enabled. Enhancements: Limitations: Dependencies:
Version 1.70 - BuildID: D7E140Z ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58N Version: 4.30 (ibm_fw_imm2_1aoo58n-4.30_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: D7E136W ------------------------------------------------- Problem(s) Fixed: 1. Can not boot up from IMM Remote Mount with USB key. 2. Fixed that LR-DIMM 1333Mhz 1.35V memory speed is incorrect at Balanced mode Enhancements: 1. Support two DIMM Per Channel run at 1866Mhz for 16GB RDIMM 1.5V DR x4 & 32GB LRDIMM QR x4 2. Variable store self-healing. Limitations: 1. When flashing UEFI from version 1.30 or later down to version 1.20 or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30. Dependencies: 1. The IMM firmware must be at BUILDID: 1AOO50D Version: 3.65 (ibm_fw_imm2_1aoo50d-3.65_anyos_noarch) or higher prior to installing UEFI version 1.60. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.50 - BuildID: D7E134E ------------------------------------------------- Problem(s) Fixed: 1. Corrected IPv6 reboot problems 2. Corrected 64bit resouce allocation problems 3. Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot Enhancements: 1. Add support for Intel Xeon processor E5-2600 v2 product family 2. Add notification when UEFI detects GPT corruption during POST 3. Add support to configure the "Next Boot to F1 setup" function out of band 4. Add long text support in F1 setup help string 5. Implement LAN Fail-Over function Limitations: Dependencies:
Version 1.40 - BuildID: D7E128D ------------------------------------------------- Problem(s) Fixed: 1. Fixed that IB mezz card still shows "Standby Power Enable/Disable item" in uEFI setup menu 2. Fixed that can not enter F1 setup menu after 3x POST failure occurred. 3. Correct the PCIE link control of Active-State Power Management(ASPM) setting to result the PCI/NMI problem 4. Fix that UA-101 audio device hang at legacy mode Enhancements: 1. Multiple PCIe adapter BARs 2. Configurable MMIO base 3. Support Firmware first feature 4. Add informational messages when existing UEFI F1 setup menu 5. Add OEM SPD feature 6. Fixed the Preboot Execution Environment(PXE) function with Emulex 10 GbE Virtual Fabric Adapter III Limitations: Dependencies:
Version 1.30 - BuildID: D7E124C ------------------------------------------------- Problem(s) Fixed: 1. Fixed that some USB device hang at legacy mode (UA-101 USB audio device) 2. Disable CPU C-state and phase shedding for Volterra EOS issue Enhancements:
Limitations: Dependencies:
Version 1.30 - BuildID: D7E124A ------------------------------------------------- Problem(s) Fixed: 1. UEFI option 43 failed to work 2. ITP can't trigger CPU2 IERR 3. MBE WHEA-log can't match ECC Uncorrectable event 4. iMM lost connection with shared NIC on Intel mezz card (Meteorite) after power cycle Enhancements: 1. Change UDIMM 2DPC@1333Mhz 1.35V algorithm to meet performance specification requirement 2. Support ROM Recovery feature (Auto Promotion under Backup Bank Management Method) Limitations: Dependencies:
Version 1.20 - BuildID: D7E120C ------------------------------------------------- Problem(s) Fixed: 1. Sevaral uEFI OS boot failed with F12 boot menu HDD0. 2. Console Switch 1754A2X with KB & Mouse are not responding in EFI Web BIOS 3. Multiple issues caused by USB over current, including: 3.1 Unable to use front USB Port to flash firmware, load operating system or install a keyboard/mouse. 3.2 VMWare Purple Screen of Death (PSOD) during OS installation or booting. 3.3 Intermittent USB configuration change under Windows. 4. Fan speed goes to 100% after enable several TPM settings. 5. TPM 1.2 UEFI Preboot Interface Test (found CPU error) Enhancements: 1. Enable DRAM phase shedding 2. Support FastSetup feature 3. Support UDIMM 2DPC@1333Mhz running at 1.35V Limitations: Dependencies:
Version 1.10 - BuildID: D7E116A ------------------------------------------------- Problem(s) Fixed: 1. E5-2690 cannot run frequency at 2.9GHz(only 2.8GHz) when turn off Turbo mode. 2. Instruction for TPM enablement has type error. 3. CPU can not enter deep C status with uEFI 11I under RHEL5.7 64 4. Failed to boot from CDDVD ROM with uEFI OS 5. Best Card cannot link with Gen3 on Mezz Card slot 6. BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event and PCI error LED was off 7. iSCSI ISID mismatch under uEFI BIOS Settings. 8. TCG TPM Integration Test (Manual) random failed under WIN2K8 R2 SP1 with uEFI_11L 9. QPI link speed and Turbo mode show incorrect with M1 stepping CPU. 10.The format of System Event Log is uncorrected 11.Legacy Thunk Support is malfunctional 12.DIMM slot 13-24 can NOT indicate which memory was falut when trigger MBE on Mirror mode by bugged DIMM 13.ASUT74H can't find any iscsi item 14.BestCard ASB_Wiz stress test is failed with Gen 3 link speed 15.Fail to set some of PXE items with ASU76h 16.Can not boot into WinPE in RAID HDD on Crossfield 17.Personality can not be switched in OCM tool no matter FOD is imported 18.Processor speed is incorrect when system is idle 19.VLAN ID can be configured to ID 0 20.PCIX Best Card cannot get software NMI when trigger some of PCIX command 21.10G PCIe slot got incorrect slot error event by PCI-E Best Card 22.PCIe BestCard expr_flow got IERR 23.PCI led on and uEFI report OUT_OF_RESOURCES when system plug-in BussardE 10GbE adapter. 24.Processor speed is incorrect when system is idle w/ E5-2637 M1 25.Console redirection can not work normally with com2com. 26.No screen output with SOL connection 27.iSCSI Attempt will disapper when system reboot several times. 28.BestCard expr_mess_fatal and expr_mess_nonfatal would not get PCI error event on Internal RAID Slot 29.Purple Screen of Death when boot/install ESXi 5.0 to Hypervisor key
Enhancements: 1. Open Optimized Boot setup item with default enable 2. Open Legacy Thunk support setup item 3. Change Operating Mode from Custom Mode to Efficiency - Favor Performance 4. Remove USB port0 OverCurrent Mapping 5. Add DriverCodeDisplay error code on screen function
Limitations: Dependencies:
Version 1.00 - BuildID: D7E112J (Initial Release) ------------------------------------------------- Problem(s) Fixed: 1. High failure rate on front USB cable position/design cause all USB device disappear and could not flash via UXSPI
Enhancements: Limitations: Dependencies:
ibm_fw_uefi_d7e146c-1_82_anyos_32-64_chg
Firmware Update for IBM High IOPS Modular Adapter
Controller Supported: - IBM 300 GB High IOPS MLC Modular Adapter (90Y4361) - IBM 600 GB High IOPS MLC Modular Adapter (90Y4365) - IBM 800 GB High IOPS MLC Modular Adapter (90Y4369) - IBM 300 GB High IOPS SLC Modular Adapter (90Y4373)
Version 7.30.05.00-1 - Non Critical -------------------- - Added Support in RHEL 5.9 indistro device driver
Version 7.30.05.00 - Initial release ------------- ibm_fw_mpt2sas_hiop-7_30_05_00-1_linux_x86-64_chg
See readme for a list of changes qlgc_fw_nic_7_12b_4_2e_linux_32-64_chg
IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.04 Build ID: SAS11404
NOTE TO SERVICE - Reference RETAIN TIP H29851 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.04 Critical Release Reference RETAIN TIP H29851
This package includes updates to drives with product ID strings of:
- TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - fixes ACK/NAK timeout and IT Nexus lost issues. In addition a change to the BLOCKLIMITSVPDPAGE field in Vital Product Data (VPD) page 0xB0 to limit the size of an UNMAP command. see Retain Tip H211424.
SAS 2.5"
Initial code Release - SMK3001GRDB, SMK6001GRDB, SMK9001GRDB to SB35
SATA 2.5"
- SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA36 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB37 - fix to prevent possible drive lock up during format.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA36 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB37 - fix to prevent possible drive lock up during format.
=================================================================== IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to E568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX
ibm_fw_hdd_sas-1_14_04-1_linux_32-64_chg
**************************************************************** | | | | | IBM Online Tape Drive/Optical Update Program | | Revision: 1.11.00.1075 Build Date: 6.23.11 | | | | (C) Copyright International Business Machines Corporation | | 2000-2011 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 6/23/2011 | | | ****************************************************************
CONTENTS:
Change History
ver 1.1
Increased the tape tension during drive cleaning from 4g to 7g, which improves the cleaning effectiveness significantly.
ver 1.0
This firmware will change the firmware of your DDS tape drive to the latest available. ibm_fw_tape_dds-1_1_linux_32-64_chg
uEFI Flash Update Version 1.92 (BuildID VVE144C) Change History
Version 1.92 - BuildID: VVE144C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428 - Addressed a problem where the PCI Generation setting was missing in the UEFI setup menus for Mezz adapters. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58T Version: 4.31 (ibm_fw_imm2_1aoo58t-4.31_anyos_noarch) or higher prior to installing UEFI version 1.92. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.80 - BuildID: VVE142E ------------------------------------------------- Problem(s) Fixed: - Corrected an issue which might cause system get an NMI event with PCIe device installed on PCIe slot 5. Enhancements: Limitations: Dependencies:
Version 1.73 - BuildID: VVE142D ------------------------------------------------- Problem(s) Fixed: - Fixed an issue with continuous reboots when applied new LSI FW and the Remote Console setting is Enabled. Enhancements: Limitations: Dependencies:
Version 1.71 - BuildID: VVE142B ------------------------------------------------- Problem(s) Fixed: Enhancements: - Supported IBM eXFlash DDR3 Storage DIMM firmware version 1.4.7. Limitations: Dependencies:
Version 1.70 - BuildID: VVE142A ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm - Supported IBM eXFlash DDR3 Storage DIMM Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58N Version: 4.30 (ibm_fw_imm2_1aoo58n-4.30_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: VVE136A ------------------------------------------------- Problem(s) Fixed: - Fix Can not boot up from IMM Remote Mount with USB key. - Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot - Fix that LR-DIMM 1333Mhz 1.35V memory speed is incorrect at Balanced mode
Enhancements: - Prevent the system unexpected shutdown with HCDIMM - Variable store self-healing
Limitations: Dependencies:
Version 1.51 - BuildID: VVE134T ------------------------------------------------- Problem(s) Fixed: - System doesn't boot to HII after Pressing 'C' with missing configuration.
Enhancements: - IVB Support. - Prevent the system unexpected power off with sensor planar voltage fault
Limitations: Dependencies:
Version 1.50 - BuildID: VVE134S ------------------------------------------------- Problem(s) Fixed: - Reboot to UEFI setup using ASU or Windows 2012 - Enable help string scroll when the help text cannot show all at current page. - Add notification and recovery option when UEFI detects GPT corruption during POST - Implement LAN Fail-Over function Enhancements: - IVB Support. Limitations: Dependencies:
Version 1.40 - BuildID: VVE128B ------------------------------------------------- Problem(s) Fixed: - IB Card show "Standby Power Enable/Disbale item" in uEFI setup menu - Can Not enter F1 setup menu after POST failure occur. - Correct the PCIE link control of Active-state power Management(ASPM) setting to result the PCI/NMI problem
Enhancements: - Multiple PCIe adapter BARs - Configurable MMIO base - Support Firmware first feature - Add informational messages when existing UEFI F1 setup menu - Add OEM SPD feature Limitations: Dependencies:
Version 1.30 - BuildID: VVE124A ------------------------------------------------- Problem(s) Fixed: - iSCSI Out of Band Configuration Fails. - Failed to change the value of some memory settings with ASU(ASUT78C). - MBE WHEA-log can't match ECC Uncorrectable event. - System administrator password is set but system still can get fully access right in F1 uEFI without asking password if press and then press . - Update uEFI README file. - IMM lost connection with shared NIC on Intel mezz card. - Onboard NIC 4 doesn't work when boot Linux OS with paramet. - System hang after memory multibit error occurred and then system reboot. - System could be hang if Intel Network adapter is installed (Dallas). - TPM setting would not be applied in ESC+SAVE issue . - The Pre-Boot value cannot set MUX switch to BMC by uEFI SETUP menu. - Kingston manufactory ID will shown as "Unknown" in SMBIOS type 17. - Fixed TCG TPM Integration manual test failed in Windows 2012. - System hang at IBM LOGO with Broadcom Dual Runner card. - Cause [W.3938002]Boot Config Error. - Disable CPU C-State and Phase Shedding to prevent Voltage Regulator EOS issue. - UEFI setting on F1 menu doesn't sync with ASU setting when boot mode=legacy only.
Enhancements: - SMBIOS type17s support 2133 data rate for dimm maximum speed. - Remove some unuseful code due to IMM changed flow when uefi primary bank integrity check failure. - Enabled DCA item in processors menu of uEFI SETUP. - Improve clock timing for Netlist 16GB HCDIMM. - Add a workaround to patch an yellow mark(AHCI) shown on Windows 2012. - Improve FoD (Feature On Demand) by Transition Table update . - Improve thermal limitation in SSD adapter (LSI High IOP, QLogic ). - Improve behavior of PCI-X error handling.
Limitations: Dependencies:
Version 1.20 - BuildID: VVE120C ------------------------------------------------- Problem(s) Fixed: - Invalid slot usage state showed on RENAI Riser card. - Incorrect slot error event on JOJO Riser. - Fail to return to Boot menu if boot fail. - Further updates to the fatal error handler to report QPI errors during runtime. - iSCSI Attempt will disapper when system reboot several times. - F6 function key is malfunction. - Remove unnecessary information from ReadMe file. - Fails to report logging limit errors on spared DIMM. - FAN speed is pull up if TXT enabled in uEFI. - Fail on Windows 2012 TPM WHQL validation.
Enhancements: - Improve 2DPC@1333MHz detection algorithm. - Improve CPU detect algorithm. - Support 4GB PCI inventory access. - Support UDIMM 2DPC@1333MHz run on 1.35V by automatic. - Remove unnecessary warm reset to improve uEFI boot time.
Limitations: Dependencies:
Version 1.11 - BuildID: VVE116C ------------------------------------------------- Problem(s) Fixed: - Fail to install VMWare 5.0 if Intel TXT function is enabled.
Enhancements: Limitations: Dependencies:
Version 1.10 - BuildID: VVE116A ------------------------------------------------- Problem(s) Fixed: - Fixed issue to allow PXE/iSCSI to be configured out-of-band - Processor speed is incorrect when system is idle w/ E5-2637 M1. - Serial Console Redirection function can not work if SP Redirection is Disabled. - No Screen output by Serial Over Lan connection. - Fix Intel E5-2637 speed is incorrect. - DIMM slot 13-24 can NOT indicate which memory was falut. - Fix SMBios Type 4 External Clock information incorrect. - Fixed issue that caused the ASU tool to occasionally fail to update the Processors.CoresinCPUPackage value
Enhancements: - Improve PCIe error reporting. - Improve Fatal Error Handle. - Improve Legacy PXE function. - Remove Intel 130W CPU limitation. - Improve PCIe error reporting. - Support Heping riser card - Improve ME Update mechanism - Improve ACPI: C-States - Added support for using Features On Demand with Optimized Boot enabled - Updated thermal threshold values for DIMMs - Reduce boot time (reduce unnessary reset in POST).
IBM 7383 (IBM system x 3500 M4) uEFI Flash Update Version 1.82 (BuildID Y5E142CUS) Change History
Version 1.82 - BuildID: Y5E142C ------------------------------------------------- Problem(s) Fixed: - Memory Latency issue. Incorporated Intel Microcode Update (MCU) MED 306E4_00000428. - Addressed a Unified Change Management (UCM) issue that was overwriting configuration changes made via 3rd party utilities - Updated UEFI to address these vulnerabilities: CVE-2014-3571, CVE-2014-3569, CVE-2014-3572, CVE-2014-8275, CVE-2014-3570 Enhancements: Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.70 - BuildID: Y5E140A ------------------------------------------------- Problem(s) Fixed: - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later to a version earlier than 1.30, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO56v Version: 3.86 (ibm_fw_imm2_1aoo56v-3.86_anyos_noarch) or higher prior to installing UEFI version 1.70. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.60 - BuildID: Y5E136A ------------------------------------------------- Problem(s) Fixed: 1. Can not boot up from IMM Remote Mount with USB key. 2. Fixed the Incorrect Uniphy Recipe programmed for S-step IVX Enhancements: 1. Variable store self-healing. Limitations: 1. When flashing UEFI from version 1.30 or later than 1.20 to version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30 or newer. Dependencies: 1. The IMM firmware must be at BUILDID: 1AOO50D Version: 3.65 (ibm_fw_imm2_1aoo50d-3.65_anyos_noarch) or higher prior to installing UEFI version 1.60. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features implemented in this release.
Version 1.51 - BuildID: Y5E134G ------------------------------------------------- Problem(s) Fixed: - Fixed system unexpected power off with sensor planar voltage fault - Fixed Performance drop issue
Enhancements: - The 2DPC@1866 especially for 16G DIMM formal code Limitations: Dependencies:
Version 1.50 - BuildID: Y5E134F ------------------------------------------------- Problem(s) Fixed: - Corrected IPv6 reboot problems - Corrected 64bit resouce allocation problems - Fix CPU frequence lockdown when UEFI recalibrates the power levels during first cold boot Enhancements: - Add support for Intel Xeon processor E5-2600 v2 product family - Add notification when UEFI detects GPT corruption during POST - Add support to configure the "Next Boot to F1 setup" function out of band - Add long text support in F1 setup help string Limitations: Dependencies:
Version 1.40 - BuildID: Y5E128D ------------------------------------------------- Problem(s) Fixed: - Incorporated Microcode Update (MCU) M6D206D7_00000710 to address Intel Erratum BT248 for System Resets with 32-bit (PAE Enabled) Guest OS and VT FlexPriority enabled. For more information, refer to IBM RETAIN Tip H21370. Enhancements: Limitations: Dependencies:
Version 1.40 - BuildID: Y5E128B ------------------------------------------------- Problem(s) Fixed:
- Fixed that can not enter F1 setup menu after 3x POST failure occurred. - Correct the PCIE link control of Active-State Power Management(ASPM) setting to result the PCI/NMI problem - Fix that UA-101 audio device hang at legacy mode Enhancements: - Multiple PCIe adapter BARs - Configurable MMIO base - Support Firmware first feature - Add informational messages when existing UEFI F1 setup menu - Add OEM SPD feature - Improved handling of memory in high stress application/usage Limitations: Dependencies:
Version 1.30 - BuildID: Y5E124B ------------------------------------------------- Problem(s) Fixed: - UEFI option 43 fails to work - Disable phase shedding and Default to disable CPU C-states - ITP can't trigger CPU2 IERR - MBE WHEA-log can't match ECC Uncorrectable event Enhancements: - Change UDIMM 2DPC@1333Mhz 1.35V algorithm to meet performance specification requirement - Support ROM Recovery feature (Auto Promotion under Backup Bank Management Method) Limitations: Dependencies:
Version 1.20 - BuildID: Y5E120D ------------------------------------------------- Problem(s) Fixed: - Sevaral uEFI OS boot failed with F12 boot menu HDD0. - Console Switch 1754A2X with KB & Mouse are not responding in EFI Web BIOS - Fail to return to Boot menu if boot fail. - IMM menu location is changed. - F6 function key is malfunction. - FAN speed is pull up if TXT enabled in uEFI. Enhancements: - Support the Trusted Computing Group's Memory Overwrite Request function. - Improve fatal error handler to report QPI errors during runtime. - Support FastSetup feature - Enable DRAM phase shedding - Support 4GB PCI inventory access. - Support UDIMM 2DPC@1333MHz run on 1.35V by automatic. - Improve messages while booting up. - Enable Phase Shedding to improve memory performance. - Improve PCIe Slot# for WidgetGetDeviceLocation procedure - Remove unnecessary warm reset to improve uEFI boot time.
Limitations: Dependencies:
Version 1.10 - BuildID: Y5E116A ------------------------------------------------- Problem(s) Fixed: - Fixed E5-2690 cannot run frequency at 2.9GHz(only 2.8GHz) when turn off Turbo mode. - Fixed fnstruction for TPM enablement has type error. - Fixed CPU can not enter deep C status with uEFI 11I under RHEL5.7 64 - Fixed failed to boot from CDDVD ROM with uEFI OS - Fixed iSCSI ISID mismatch under uEFI BIOS Settings. - Fixed TCG TPM Integration Test (Manual) random failed under WIN2K8 R2 SP1 with uEFI_11L - Fixed QPI link speed and Turbo mode show incorrect with M1 stepping CPU. - Fixed the format of System Event Log is uncorrected - Fixed Legacy Thunk Support is malfunctional - Fixed DIMM slot 13-24 can NOT indicate which memory was falut when trigger MBE on Mirror mode by bugged DIMM - Fixed ASUT74H can't find any iscsi item - Fixed Fail to set some of PXE items with ASU76h - Fixed Can not boot into WinPE in RAID HDD on Crossfield - Fixed Personality can not be switched in OCM tool no matter FOD is imported - Fixed fail to set some of PXE items with ASU76h - Fixed Processor speed is incorrect when system is idle - Fixed VLAN ID can be configured to ID 0 - Fixed Processor speed is incorrect when system is idle w/ E5-2637 M1 - Fixed Console redirection can not work normally with com2com. - Fixed No screen output with SOL connection Enhancements: - Added Legacy Thunk support setup item - Change Operating Mode from Custom Mode to Efficiency - Favor Performance - Added DriverCodeDisplay error code on screen function - Improve PCIe error reporting. - Improve Fatal Error Handle. - Improve Legacy PXE function. - Remove Intel 130W CPU limitation. - Improve PCIe error reporting. - Support Heping riser card - Improve ME Update mechanism - Improve ACPI: C-States - Added support for using Features On Demand with Optimized Boot enabled - Updated thermal threshold values for DIMMs - Reduce boot time (reduce unnessary reset in POST). Limitations: Dependencies:
**************************************************************** | | | Tape LTO firmware update | | | | | | (C) Copyright International Business Machines Corporation | | 2000-2012 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 1/29/2013 | | | ****************************************************************
Change History
ver 1.7 To update the LTO 3 v2 firmware to C7RD To update the LTO 4 v1 firmware to C7Q5 To update the LTO 4 v2 firmware to C7RD To update the LTO 5 v1/v2 firmware to C7RD
ver 1.6_01 To update the initilialization file for reflash tool and the new version of LTO Gen 4 v1 firmware into BBH5.
ver 1.6_00 updated firmware for LTO42 to BBNF updated firmware for LTO32 to BBNF ver 1.5_00 updated firmware for LTO 3 to BBNF updated firmware for LTO 4 to BBNF updated firmware for LTO 5 to BBNM
ver 1.4_04
updated firmware for LTO 5 to BBNB
ver 1.4_01
updated firmware for LTO 4 to A23E
ver 1.4_00
updated firmware for LTO 5 to A6S1 updated firmware for LTO 4 to A231
ver 1.3_02
update .txt and .chg files
ver 1.3_01
corrected XML / TML file names for new firmware (A4Q1 -> A5M1)
ver 1.3_00
updated firmware for LTO 5 to A5M1
ver 1.2
updated firmware for LTO 5 to A4Q1
ver 1.1
updated XML / TML to add new systems
ver 1.0
This firmware will change the firmware of your LTO tape drive to the latest available, unless it is already at the latest level.
- IBM HH LTO5 SAS (49Y9898 - 3628L5X - 3628N5X) @ A2C1 - IBM HH LTO1 SCSI (24P2396 - Newton) @ N2CG - IBM HH LTO1 SCSI (24P2396 - Pompy) @ P63I - IBM HH LTO2 SCSI (39M5658) @ 0468 - IBM HH LTO3 SAS (43W8478) @ 93G1 - IBM HH LTO4 SAS (44E8895) @ 93Y1 - IBM FH LTO1 SCSI (00N8016) @ 59C0 - IBM FH LTO2 SCSI (59P6744) @ 8571 - IBM FH LTO3 SCSI (39M5657) @ 87G0 ibm_fw_tape_lto-1_7_linux_32-64_chg
QLogic 10 GbE Converged Network Adapter MultiFlash Update for System x IBM P3P Firmware Change History QLogic Corporation. All rights reserved.
Package Version 2.20.22
Release Version: 2.20.22
Table of Contents 1. Version 2. Changes 3. Limitations 4. Known Issues 5. Additional Information 6. Trademarks 7. Notices 8. Contacting Support
1. Version
The files contained in this Flash image package are zipped into a file that will expand to provide the following versions for the 3200/8200 Series Adapters.
* Flash Image Version 2.20.22
P3P22022.BIN contains: ---------------------- * NIC PXE (3200/8200 Series) PXE 3.0 version 2.0.2.37 PXE EFi version 2.6.19 signed * FCoE BIOS (8200 Series only) BIOS 3.0 version 3.27 uEFI version 6.09 Signed * iSCSI BIOS (8200 Series only) BIOS 3.0 version 2.19 uEFI version 2.04.12 signed * Firmware - v4.16.151 * Pegtune - v4.16.32 * Bootloader - v4.16.05 * CRBinit - v4.12.07
Hardware Support Standard Servers with PCIe 1.1 and 2.0 x8
3. Limitations
None
Industry Standards Compliance N/A
4. Known Issues
5. Additional Information None
6. Trademarks Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
7. Notices Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
8. Contacting Support Please feel free to contact your QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached at:
Gary Stift gary.stift@qlogic.com
(c) Copyright 2014. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
qlgc_fw_cna_sysx-2_20_22_linux_32-64_chg
=================================================== Change History =================================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.5.5 Latest Driver Version: 3.2.5.5 Document Updated: 04/20/2015 Product: QLogic BR Series FC/NIC/CNA
Please visit www.qlogic.com for full documentation, additional drivers, and management applications.
Version 3.2.5.5 Fixes and Enhancements: - Boot FW, UEFI, HCM related fixes - MCP work around
Version 3.2.5.0 New Features and Feature Enhancement: - Support for RHEL5.11, RHEL6.6 and RHEL7.0
Version 3.2.4.0 New Features and Feature Enhancement: - Support for RHEL5.10 and RHEL6.5
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
Version 3.2.0.0 Release for FC/NIC/CNA
New Features and Feature Enhancement: - Updated code for Brocade 1867 IBM Flex System FC5022 FC Adapter for x22 - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Fixes or enhancements: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Version 3.1.0.1 Release for 16G FC/NIC/CNA
Adapter Features - Updated code for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A
Version 3.0.3.1 Initial release for 16G FC/NIC/CNA
Adapter Features - Initial support for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A brcd_fw_cna_3_2_5_5_linux_32-64_chg
Firmware Version: 2.82x6 (w/ 5.12a13 Universal Boot Code) (Supported for IBM System x & BladeCenter)
Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM (BOFM) - Emulex FC configuration utility is in the wrong F1 setup screen
- Multiple adapters connected to same PCIe bridge port can request more I/O space than system can allocate. - Updated firmware kernel code so Saturn based HBA and mezz cards do not use or advertize need for system I/O Space.
**************************************************************** | | | | | IBM Online Tape Drive Update Program | | Revision: 1.10.01.1073 Build Date: 3.3.10 | | | | (C) Copyright International Business Machines Corporation | | 2000-2010 . All rights reserved. | | | | US Government Users Restricted Rights -- Use, duplication | | or disclosure restricted by GSA ADP Schedule Contract with | | IBM Corp. | | | | Note: Before using this information and the product it | | supports, read the general information under "NOTICES AND | | TRADEMARKS" in this document. | | | | Updated: 1/28/2013 | | | ****************************************************************
CONTENTS:
Change History
ver 1.6
To release FW v0195. The change from v0185 is to refine the code and no function change for system x.
ver 1.5
Update to fix the failure in FW updating with cartridge inserted in the drive (from v0145 up to v0185). The way to make drive FW update in the VMware environments is added in the readme.
ver 1.4
Initial release of the Tandberg Data RDX USB 3 backup drives. This FW update cover the drives of the IBM P/N 362532Y, 362550Y, 36251TY, 00D2786,00D2787 and 00D2788.
ver 1.1
Updated drive string to include: Imation RDX-USB (in addition to IBM RDX) Updated 'tapedrv' to version 1.10.01.1073 Updated to include more systems
ver 1.0
This firmware will change the firmware of your RD drive to the latest available, unless it is already at the latest level.
This is the initial release of the RD package file, so there are no changes to describe. ibm_fw_tape_rd-1_6_linux_32-64_chg
ServeRAID M5100 Series SAS/SATA Controller Firmware Update for Linux
Adapters Supported: ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) ServeRAID M5110e SAS/SATA Controller for IBM System x ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 23.33.0-0018 - High Impact/High Probability of Occurrence ----------- Fixes: - Incorporated MegaRAID FW stack 5.13 - Fixed an issue where drive temperature cannot be displayed for a drive in Failed or Foreign state (SCGCQ00693959) - Fixed an issue where after creating an LD via StorCLI or MSM the firmware writes into saved power condition mode page (0x1a) of all PDs in the LD and enables their idle timers (SCGCQ00658701) - Fixed an issue where Patrol Read would sporadically correct the same defective LBA repeatedly (SCGCQ00729591) - Fixed an issue where importing a Foreign array onto a new controller may fail with "Cannot force emulate VD to 512E since enable512Esupport is false" error in firmware log (SCGCQ00721106) - Fixed an issue where the controller may enter MegaMon sporadically (SCGCQ00776409) - Fixed an issue where MSM may not report a Full Initialization Aborted error until system rebooted (SCGCQ00759100) - Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350) - Fixed an issue where Link Speed may show UNKNOWN when attaching a 3G or 6G SATA drive (SCGCQ00803522) - Fixed an issue where StorLib may return 0x00ff (fail) code even though operation succeeds when creating a VD out of an existing drive group (SCGCQ00827685) - Fixed an issue where format process of SSD may take much longer than in previous firmware (SCGCQ00674388) - Fixed an issue where controller must have cleared config to enable 240VD unless existing config only included single-drive RAID0 VDs (SCGCQ00559643) - Fixed an issue where some commands would timeout with CDB=ff ff ff ff (SCGCQ00459760) - Fixed an issue where slot ordering in iMR mode might differ from slot numbering in MR mode (SCGCQ00559274) - Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives, preventing data issues (SCGCQ00830977) (RETAIN TIP H214323)
Features/enhancements: - Added support for 512e drives (SCGCQ00425363) Enhanced Event Log to include CVPM health details after every Learn Cycle to allow closer monitoring of CVPM health (SCGCQ00819877) - Implemented a retry for reads of CVPM data to avoid erroneous event 386 or 150 in the Event Log (SCGCQ00392439) - Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490819) - Implemented ability for firmware to read drive temperature immediately following SAS discovery (SCGCQ00602573) - Added ability to clear the MaintainPdFailHistory (SCGCQ00474559)
Version 23.29.0-0015 - Critical ------------------- Enhancement - Provide mechanism to disable PCIe backchannel training via SBR. Fixes: - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where foreign configuration import could fail. - Fixed an issue where storcli.exe /c0 show all command repeatedly prints to termlog with respect to upgradekey presence. - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the order of the first 64 VDs in the POST is not the same sequence as returned from the firmware. - Fixed storCLI adpfwflash option crash and adpallinfo option failure. - Reduced the bootblock Init time, which effectively reduces the configuration retry time to approximately 700 mS.
Version 23.22.0-0024 - Non-Critical ------------------- Enhancement(s): - Display the Native Command Queuing (NCQ) enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI. - Added support for ServeRAID M5100 Series 2GB Flash/RAID 5. Fix(es): - Disable PI CRC checking when the drive is not initialized during a CC. - Increased the SuperCap learn time out value for 2GB TMM-B solution. - Fixed an issue for 2GB memory modules where SuperCap does not get connected to the controller and hence cache offload fails. - Fixed an issue where cache policy of virtual drives(VD) does not change to write through(WT) mode even after detecting a bad supercap. - Fixed an issue where a RAID configuration created with physical disks in powersave mode could be lost after rebooting the system. - Fixed an issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed an issue where the system is not allocating memory correctly when MR and iMR controllers are in the same system. - Fixed an issue where deep learn does not start immediately when the relative state of charge (RSOC) is just equal to 95%. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled.
Version 23.16.0-0027 - Critical ------------------- Fix(es): - Addressed data exposure issue when using CacheCade - Fixed issue where Supercap shows 0 Capacitance - Fixed iBBU09 battery issue that caused a VD cache policy to remain in write-through mode after a manual relearn - Fixed iBBU09 battery issue that caused a VD cache policy to periodically toggle between write-back/write-through mode - The limits for iBBU09 battery charging were not updating properly in a learn cycle - Ensures a single supercap pack is not supported on 2GB memory module. - Resolves a firmware crash seen while doing continuous sas cable pulls. - Ensures OpROM loads even if segment address is 0xC0000. - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.16.0-0018 - Suggested ------------------- Fix(es): - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.12.0-0016 - Suggested ------------------- Fix(es): - Added isync to prevent speculative execution while memory is being allocated. - Delayed enablement of POM until AFTER valid memory range is provided by host system.
Version 23.12.0-0011 - Suggested ------------------- Enhancement(s): - Support for 512e and 4k SAS/SATA hard drives added - Implemented Limited Band Charging for iBBU09 (RETAIN tip H21631) - Changed BIOS check to determine if running in HAMR, in order to ensure nothing gets broken when user has an iButton which is not programmed. - Changed controller status for safe mode to show controller status as safe mode and disable debug message logging in serial port.
Fix(es): - Addressed an issue where deeply discharged Cache Vault Power Modules would be prematurely be marked as failed. - Fixed an issue where HII hangs when trying to enter configuration management while in safe mode. Changed the safe mode warning message as below: "Controller is running in safe mode. Safe mode is used for diagnostic purposes only. Limited operations such as Configuration Preview, Clear Configuration and View/Change Controller Properties are allowed in this mode. Other operations such as Create Configuration, Import and Clear Foreign Configurations are not allowed. To exit safe mode, correct the fault, and reboot your computer." - Fixed an issue where having more than three adapters results in a calculation error for the offset to store physical disk info for fourth adapter, due to BIOS not clearing upper byte of AX (that is AH which is containing some non zero value). - Fixed an issue where the Wrong spanned drive group size is displayed by WebBIOS (Ctrl-H).
Version 23.7.1-0010 - Suggested ------------------- Fixes: - Fix an issue related to the where the TSOC (EEPROM) is not able to read or write from the firmware which will result in the message "Incompatible secondary iButton present." - Fix a HII broswer issue where Cachecade virtual drive can be selected as a boot device. - Fix a HII broswer issue where the user is unable to clear the controller configuration when there are no drives attached. - Fix an issue where the BIOS doesn't display the RAID level and VD size correctly at BIOS POST.
Version 23.7.1-0009 - Suggested ------------------- Fixes: - Fixed an issue where SoH is bad after a learn cycle but iBBUI shows good status. - Fixed an issue where hi-temp warning was not being displayed.
Version 23.7.0-0037 - Suggested ------------------- Fixes: - Corrected differential signals for Phys 2 and 3 that caused slot numbers in simple swap configurations to be incorrect. - Fixed an issue when 'maintain PD failed history' is enabled, and a cable is removed while a drive is added, the drives state goes to optimal instead of foreign unconfigured bad. - Fixed a problem where a capacity change is reported after a rebuild completes on a Cache Cade volume. - Fixed a controller firmware hang when the recovery of a medium error takes to long. - Fixed an issue where the SATA BBM (Bad Block Manager) list was being corrupted. - Fixed an issue where FoD (Feature on Demand) Options were being lost because of errors while accessing the TSOC. - Fixed a problem where the controller firmware would crash and drives would go offline when a bad block entry was created during a check consistency operation. - Fixed a problem where drives were being marked unconfigured bad (foreign) on reboot. - Fixed problem where a member of a CacheCade volume did not get marked as foreign when the drive was pulled with 'maintain PD failed history' enabled. - Fixed a problem where during a rebuild, a former hot spare that was now in a state of unconfigured good, moved back to the state hot spare, which then automatically started a copyback operation, causing the rebuild to restart. - Fixed a problem where a controller fault occurred during a reboot while a physical device was in progress of a PD Erase.
Version 23.7.0-0029 - Suggested ------------------- Enhancements: - Added support for Cache Cade 2.1 - Added Support for PI Drives
Fixes: - Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup. - Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive - Added a check for the presence of PD before writing the data arms of a protected LD during BGI. - Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS. - Fixed an issue with USB Cacheoffload restore fails after multiple power cycles onServeRAID M51xx controllers. - Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data. - Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash. - Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds. - Fixed background initialization watermark conversion to PD LBA. - Fixed write protected R1E data arms during initialization. - Fixed an issue where MR firmware crashed while discarding pinned cache. - Fixed an issue where a dirty LD dependency information of SSD pd has stale entries. - Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd - Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset. - Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe. - Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM. - Fixed an issue where the firmware was wrongly adding puncture entries. - Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table. - Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event. - Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events. - Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled. - Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value. - Fixed an issue in which a Patrol Read may not start under certain conditions. - Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved. - Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero. - Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU. - Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed. - Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running. - Fixed an issue where CC stops progressing on a R6 VD with media errors. - Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test). - Fixed an issue where controller features are lost if RAID Key was not detected. - Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering. - Fixed an issue where "Native configuration is no longer supported" message in post. - Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low. - Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Version 23.2.1-0043 - Suggested ------------------- Fixes: - Fixed an issue where "Potential non-optimal configuration due to drive PD commissioned as emergency spare" alarm would trigger erroneously. - Fixed an issue where Copyback does not progress upon inserting drives. - Fixed an issue When allowMixInLD is Disabled, and causes Copyback Fails after Rebuild to Emergency Hot Spare. - Fixed an issue where the Firmware faults while flashing. - Fixed an issure where querying SMART / PFA Status to Return all zeros in Sense Data. - Fixed an issue where the Re-inserted Drives becomes Unconfigured_good causing auto rebuilds to fail to start.
Version 23.2.1-0033 ------------------- - Initial release ibm_fw_sraidmr_5100-23_33_0-0018_linux_32-64_chg
BIOS and Firmware Update for ServeRAID M5200 Series SAS/SATA Controllers
Adapters Supported: ServeRAID M5225-2GB SAS/SATA Controller ServeRAID M5210e SAS/SATA Controller for IBM System x ServeRAID M5210 SAS/SATA Controller
NOTE TO SERVICE - Reference RETAIN #N/A
Version 24.7.0-0052 - High Impact/High Probability of Occurrence ------------------- Fixes: Incorporated MegaRAID FW stack 6.6 Fixed an issue where a drive reporting itself as 0MB shows up as Unconfigured Good (SCGCQ00784319) Fixed an issue where the firmware might hang during error handling of sense code 0b/47/xx (SCGCQ00701744) Fixed an issue where some SSDs may cause the system to hang at POST (SCGCQ00595506) Fixed an issue where an iMR RAID config may fail to import to 12gbps MR (SCGCQ00833765) Fixed an issue where R0, R5 and R6 read bandwidth dropped abruptly at 256K block size with 24drive SATA SSD config (SCGCQ00609808) Fixed an issue where RAID10 performance is under-performing (SCGCQ00794773) Fixed an issue where in some cases the LSI chip would convert an incoming chip reset to a system reset (SCGCQ00664261) Fixed an issue where many pRdm/pRequest/pReply messages would appear in LSI firmware log (SCGCQ00752195) Fixed an issue where when a consistency check is aborted, the adapter may reset (SCGCQ00819811) Fixed an issue where Patrol read does not start and gives incorrect warning message (SCGCQ00728404) Fixed an issue where the controller may reset unexpectedly during error handling (SCGCQ00825126) Fixed an issue where StorCLI may report Enclosure Not Found (SCGCQ00843146) Fixed an issue where x880 nodes may report excessive 'SCL STUCK Low! While I2C Rx Receiving Data' in LSI firmware log (SCGCQ00728935) (Retain TIP H213891) Fixed an issue where the command timeout for FED (SED) drives is too short, resulting in 05/2C codes (SCGCQ00797355) Fixed an issue where bandwidth falls as queue depth increases on R5/R6 24/40 drive SAS HDD configs at 256k block size (SCGCQ00701768) Fixed an issue where some drives may get bad PI CRC even though data is correct resulting in drive failure (SCGCQ00819314) Fixed an issue where the firmware may exposed more than 240VDs to host even if host driver doesn't support that many (SCGCQ00829214) Fixed an issue where MSM may display an error message if 'Schedule Consistency Check' is selected (SCGCQ00832908) Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives, preventing data issues (SCGCQ00838953) (Retain TIP H214323) Fixed an issue where the MegaRAID POST may display "The native configuration is not supported by current firmware" (SCGCQ00812842) Fixed an issue where the EFI Driver Health Protocol will show Fail when more than 64VDs are configured (SCGCQ00830918) Fixed an issue where OS may BSOD when upgrading firmware on a controller the OS has booted from if Online Controller Reset is performed (SCGCQ00825725) Fixed an issue where controller wouldn't go to halt state after multibit ECC errors detected (SCGCQ00783186) Fixed an issue where Opal-compliant FDE (SED) drives were being marked as FDE/SED when they shouldn't be (SCGCQ00788250) Fixed an issue where correctable ECC error interrupts were being masked (SCGCQ00814997) Fixed an issue where reconstructed VDs were not being reflected in MSM until system reboot (SCGCQ00839018) Fixed an issue where controller commands may fail when an LD is deleted during reconstruction (SCGCQ00821693) Fixed an issue where firmware would go to MonTask when making VDs offline while a Rebuild is occurring under IO (SCGCQ00825775) Fixed an issue where commands to FDE (SED) drives may not respond within 500ms (SCGCQ00844445) Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00844447) Fixed an issue where HDD/SSD microcode updates may report fail even though they succeeded (SCGCQ00553252) Fixed an issue where slot numbers may be wrong systems with 32 drive slots (SCGCQ00529592)
Features and Enhancements Improved Jetstress / Exchange latencies (SCGCQ00717161) Added support for Learn Cycle debug commands in firmware (SCGCQ00814991) Added ability to clear the MaintainPdFailHistory (SCGCQ00474559) Improved drive rebuild performance (SCGCQ00427581) Improved Cache Offload error handling on read from the flash interface (SCGCQ00524419) Improved average latency and max latency in Windows operating systems (SCGCQ00671670) Implemented power throttling (SCGCQ00457280) Improved load balancing on >2 drive R1 VD of SSDs (SCGCQ00593588) Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490822) Added support for communicating with multiple controllers over I2C (SCGCQ00485924) Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00651680) Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00399739) Improved accuracy of ROC temperature display (SCGCQ00575037) Increased range of priorities for background tasks, CC/PR/Rebuild/Migrate/BGI (SCGCQ00313882) Added support for 512e drives (SCGCQ00619363) Prevented a situation where there may be excessive overtemp warnings in the firmware log (SCGCQ00820067) Improved DDR3 signalling margin during heavy I/O workloads (SCGCQ00824711)
Version 24.2.1-0052 - Non-Critical ------------------- Enhancement(s): - Added a special handling for interactive password. - Implemented mechanism to allow system BIOS to put entries for iMR memory allocation into proper table. Fixes: - - Fixed an issue where boot message ‘cached data was lost,’ even when there was no battery present. - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key.resent. - Fixed an issue where foreign configurations fails to import maximum number of configurations. - Fixed simpleswap port mapping. - Fixed an issue where 'Cli show all' command fails with error msg 'Error! App exec failed in FW PCLIError! Internal.' - Fixed an issue where ‘Cli show all’ command fails with error message ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an issue where Coherency bit was not enabled in SRAM TLBs.
Version 24.2.1-0045 - Non-Critical ------------------- Fixes: - Fixed an issue where cache offload failured with pinned cache on R5 VD. - Fixed an issue where using upper case characters in command 'cli set securitykey' fails with error code '1001' and error message 'invalid key.' - Fixed an issue where system would not boot into legacy mode. - Fixed an issue where default setting of VD doesn't reflect MFC's setting. - Fixed an issue where ‘Cli show all’ command fails with error msg ‘Error! App exec failed in FW PCLIError! Internal.’ - Fixed an where ServeRAID M5210 showed the wrong slot numbers in both MR and iMR, in both HII and MSM.
Version 24.2.1-0027 - Non-Critical ------------------- Enhancment(s): - Added support for ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade for IBM System x (47C8668) - Added event in firmware to indicate that an INIT operation was halted due to reboot or other failure Fixes: - Increase backplane support to 32 slots. - Enable 512E support. - Fixed an issue where system is not allocating memory correctly when MR and iMR are in the same configuration - Fixed an issue where the user is Unable to create a RAID10 through Ctrl R using 4k drives. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled. - Fixed an issue where switching between external key management (EKM) and Local Key Management (LKM) without rebooting results in the current secret key string becoming invalid/null. - Fixed an issue where cache memory size is listed as zero in controller Information. - Fixed an issue where re-keying a controller with External key management (EKM) enabled and rebooting the system results in a corrupted key ID and an error message "Unable to communicate with EKMS ..." is displayed. - Fixed an issue where performing an online firmware update or online controller reset (OCR) on a controller with External key management (EKM) enabled, results in all secured drives marked as foreign. - Fixed an issue where CacheCade volumes, which are not supported, could be created using 4K SSD's. - Fixed an issue where removing the last physical drive of arrays could result in a firmware fault. - Fixed an issue where MegaRAID Storage Manager does not show an option to create virtual drives when the first drive in the array is missing in a partial virtual drive where all drives are configured. - Fixed an issue where switching the security mode from external key management (EKM) to local key management (LKM) on iMR controller will result in a corrupted controller key. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect.
Version 24.0.2-0013 ------------------- -Initial release ibm_fw_sraidmr_5200-24_7_0-0052_linux_32-64_chg
ServeRAID M1000 Series SAS/SATA Controller Firmware Update
Adapters Supported: ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
Version 20.13.1-0200 - Critical ------------------- Enhancement: - Support LSI iMR Private Interface for Intel iOMMU/VT-d Support when combined with latest system uEFI - Display drive speed for 12 GB Seagate hard drives in MSM. - List battery status in BIOS as N/A for iMR controllers Fixes: - Fixed incompatibility issue with System x3200/3250 M3 causing hang condition (RETAIN Tip H211826) - Fixed an issue where self-encrypting (SED) hard disk password fails to allow access to virtual disk configurations. - Fixed an issue where the ‘cli set securitykey=Lsi@12345’ command fails with error code 1001 and error message invalid key. - Fixed an issue where WebBIOS advanced software option locks the server. - Changed patrol read completion time calculation to include time for associated IO operations. - Fixed SGPIOs signal issue.
Version 20.11.1-0184 - Suggested ------------------- Fixes: - Updated SBR to avoid an errata that could cause correctable CPU errors on some systems. - Fixed an issue where NULL events may show in event log, preventing capture of controller event logs.
Version 20.11.1-0137 - Suggested ------------------- Enhancement(s): - Update recovery mode page (WriteRetryCount and recoveryTimeLimit) during discovery of a drive and during spinup recovery when sense 6/29 is received.
Fixes: - Fixed an issue where certain drives were reporting a temperature of 65 degrees Celsius. - Fixed an issue where systems with SSD HDD will pop up an error message after creating a virtual drive via HII on M1115. - Fixed an issue where the drive state is not modified when a recon virtual drive is created from the reboot path.
Version 20.10.1-0107 - Suggested ------------------- Fixes: - Fixed grammatical errors in WebBIOS. - Fixed an issue in WebBIOS Drive Group Definition screen where enclosures should not be selectable in the Drives column. - Fixed an issue in uEFI-WebBIOS where the white bars do not match up under VD properties page. - Fixed an HII browser issue where a drive performing a copyback displayed the state as "Replacing" but other utilities showed the state as copyback. - Fixed an HII browser display issue where SATA drives showed "0" for the value of RPM under drive properties. - Fixed a display issue where the HDD port number showed incorrectly in an HII browser. - Fixed an HII browser issues where creating a global hotspare gave the user an error message. - Fixed an HII browser issue when security is changed with local key management the changing security report current mode is disabled as external keu management. - Fixed an HII browser issue where the user got the following error message, "The request command has invalid arguments," when changing the security key report. - Fixed an HII browser issue where the user was unable to save the configuration after adding an extra span during array creation. - Fixed an HII browser issue where the return value was not correct when the browser called extract config with a result of null.
Version 20.10.1-0101 - Suggested ------------------- Fixes: - Fixed an issue where a system uefi error will occur when the bootTargetId is set to 0. - Fixed a problem where the firmware will allocate the sata bbl entry for the drive when moved from unsupported to supported. - Fixed a firmware issue where the TargetId for the recon LD should be set to its original LD. - Fixed a HII error message "Question Value mismatch with Option value!" after selecting factory defaults in HII. - Fixed an issue where the firmware fails to create the configuration and utilities fail to report the VD size after the reconstruction.
Version 20.10.1-0091-01 - Non-Critical ------------------- Fix - Fixed issue where update may fail to find all supported controllers in SLES 11 SP 2. Note not change in the firmware; it is the same as package 20.10.1-0091.
Version 20.10.1-0091 - Suggested ------------------- Enhancement: - Add support for ServeRAID M1115
Fixes: - Fixed issue where after starting a reconstruction on a RAID 0 the progress %, does not increase. - Fixed an issue where a new drive, inserted after a drive failure, goes to JBOD and not auto rebuild. - Fixed physical drive count issue that stated more than (16) devices already exists
Version 20.10.1-0069- Suggested ------------------- Enhancement: - ServeRAID M1015 Dimmer Switches are disabled by default.
Fixes: - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Fixed issue where WebBIOS gives garbled message when enabing FDE on an existing Disk Group - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed a problem where firmware was taking to long to complete the PCI config read. Causing the system to generate an NMI. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed an intermittent RAID key failure during power-on.
Version 20.10.1-0052- Critical ------------------- Enhancement: - Add support to pass SMART errors for JBOD drives to MSM
Fixes: - Added check to return SCSI sense Check condition if PMI is set and LBA is non zero for SCSI Read Cap 16. - Fixed issue where a bluescreen occurs handling RAID 1 with HSP and medium errors. The bluescreen occurs becausethe driver timesout while fw is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early
Version 20.10.1-0045 - Critical ------------------- Fix: - Fixed issue where firmware has incomplete writes during power fail and recovery
Version 20.10.1-0036 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users to downlevel firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur
Version 20.10.1-0022 - Critical ------------------- - Fixed issue where Windows 2008 R2 WS08 cannot be installed properly on ServeRAID M1015 SATA JBOD with a uEFI boot. - Added warning message when user tried to change more then 16 drives to JBOD. - Addressed a problem where direct attached drives are given incorrect slot numbers - Added fixes from LSI channel products. - Fixed issue where a single JBOD drive will not boot after a Windows 2008 R2 installation.
Version 20.5.1-0014 - Critical ------------------- - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed problem where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 20.1.1-0059 - Critical ------------------- Fixes: - Fixed an issue where a physical drive that is changed to JBOD from powersave will become unconfigured good again - Addresses an issue where data becomes inaccessible when a drive is secured after data has been written
Version 20.1.1-0049 - Suggested ------------------- Enhancement - Support M1000 key for RAID 5 and SED support
Fixes: - Fixed an issue in M3950M3 where webbios would hang - Fixed an issue where the controller properties in WebBIOS such as Rebuild, CC and BGI are not changing when we use up and down arrow keys. - Fixed an issue where Enclosure ID's are not being shown in MSM
Version 20.1.1-0046 - Suggested ------------------- - Enabled support for the ServeRAID M1000 Series Advanced Feature Key.
Note: All Logical Drives must previously have the encryption enabled before data is written on to the SED drives. Please read Retain TIP H123152 for more details.
Version 20.1.1-0042 ------------------- - Initial release ibm_fw_sraidmr_1000-20_13_1-0200_linux_32-64_chg
======================================================= Change History for Qlogic NIC Driver for SLES 11 ======================================================= Document Name: Change History Document Status: IBM General Avalibility Document Name: Change History Document Status: IBM General Avalibility Document Version: 5.3.6.1 Package Version: 5.3.61.1 Latest Driver Version: 5.3.61.1 Document Updated: 09/25/2014 Product: Qlogic Linux NIC Device Driver
======================================================= Please visit www.qlogic.com/hba for full documentation, additional drivers, and management applications.
Version 5.3.61.1
Package version: 5.2.46.4.c Package version updated due to updated tools within package.
Please visit www.qlogic.com/hba for full documentation, additional drivers, and management applications.
Driver Version: 5.2.46.4
Driver Version: 5.0.29.4 Initial release of Qlogic NIC Driver for SLES 11
qlgc_dd_nic_qlcnic-5_3_61_1_sles11_32-64_chg
Broadcom NetXtreme I Firmware Update Utility for IBM servers and options using the Broadcom NetXtreme I ethernet adapters.
Version 17.0.4.5a, June 08, 2015
This update package supports the following Broadcom devices: =========================================================== - BCM5717 NetXtreme I LOM - BCM5718 NetXtreme I LOM - BRCM5718 NetXtreme I Gigabit Ethernet Adapter / Product No: 49Y7900 - BCM5719 NetXtreme I LOM - BCM5719 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9352 - BCM5720 NetXtreme I Gigabit Ethernet Adapter / Product No: 90Y9370
This update packages updates your Broadcom LOM/Adapter Firmware Code to the levels shown below: Firmware code: Version Previous ==================== ======== ========== Bootcode for 5717 1.63 1.63 Bootcode for 5717C0 2.07 2.07 Bootcode for 5718 1.63 1.63 Bootcode for 5719 1.41 1.41 Bootcode for 5720 1.36 1.36 EFI Undi 16.8.4* << 16.8.4 iSCSI Boot 7.10.4 7.10.4 PXE NX1 16.8.0 16.8.0 NCSI Firmware NX1 1.3.04 1.3.04
Note: An asterisk (*) following a version number represents a certified driver. Arrows (<<) between versions indicate the component has been updated from the previous released software kit.
brcm_fw_nic_17_0_4_5a_linux_32-64_chg
BIOS/FW/UEFI Update for IBM N2200 Series SASC/SATA HBA Controllers
Controller Supported: IBM N2215 SAS/SATA HBA for IBM System x (47C8676) IBM N2225 SAS/SATA HBA for IBM System x (00AE912) IBM N2226 SAS/SATA HBA for IBM System x (00AE916)
Ehhanncements: - Add support for N2225 and N2226 SAS/SATA HBA Controllers Fixes: - Fixed an issue where SAS SSDs may not show up in the uEFI configuration Utility (HII)