IBM HBA/LSI Onboard 6Gb SAS/SATA/SSD Driver for Linux
Supported Controllers: - IBM N2125 SAS/SATA Controller (46C9011) - IBM N2115 SAS/SATA Controller (46C8989) - IBM 300 GB High IOPS MLC Modular Adapter (90Y4361) - IBM 600 GB High IOPS MLC Modular Adapter (90Y4365) - IBM 800 GB High IOPS MLC Modular Adapter (90Y4369) - IBM 300 GB High IOPS SLC Modular Adapter (90Y4373) - ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492) - IBM 6Gb SAS HBA (46M0907) - IBM 6Gb SSD HBA (68Y7362) - Onboard LSI 2004 SAS
Version 18.00.01.00 - Suggested ------------------ Enhancements: - Add support for RHEL 6.4 and 6.5. - Turn off the Predictive Failure LED when a drive is removed. - Added support to issue a Start Stop Unit command (stopping the target) to all non-IR direct-access SATA devices before the driver is shut down or unloaded. Fixes: - Fixed an issue where the driver message logs contains an entry "mpt2sas0: _base_get_ioc_facts: failed going to ready state, when the controller is in operational state. - Fixed an issue where a kernel panic observed after issuing controller diagnostic reset. - Fixed an issue where a kernel panic observed when an enclosure is removed load while the driver module is loading. - Fixed and issue where component drives of a volume go missing once the volume is deleted. - Fixed and issue where the mapping of reply queues used for IO requests coming from each CPU is not balanced when number of CPU cores are greater than the number of MSI-X vectors. - Fixed and issue where the set_affinity.sh script fails on the systems having more than 32 CPU cores. - Fixed an issue where device entries are removed when async scanning mode is enabled and device scanning is in progress.
Version 15.00.00.00 - Suggested ------------------ Enhancements: - Add support for RHEL 6.2 and 6.3 - Added support for N2115/N2125 SAS/SATA, 300GB MLC (90Y4362), 600GB MLC (90Y4366), 800GB MLC (90Y4370) and 300GB SLC (90Y4374)
Fixes: - Fixed issue where the phy disks are not discovered when the volume members are hot removed, and added while performing diag reset. - Fixed issue where SAS HBA 6Gb adapters fails Read Capacity 16 command sent to Tape drives. - Fixed issue where a device scan following a host reset could get stuck in an infinite loop. - Fixed issue where driver goes into a infinite loop when the REPORT_LUNS command gets a check condition. - Fixed issue where driver does not comply with the updated timing requirements for issuing a Hard Reset. - Fixed issue where missing delay was not getting set during system boot-up kernels 2.6.20 and newer.
Version 10.30.00.00 - Initial release for RHEL 6 ------------------ ibm_dd_mpt2sas_18_00_01_00_rhel6_32-64_chg
=============================================================================== Emulex 16GB FC Firmware Package ===============================================================================
Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex
Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change
Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console)
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 1.1.43.21 Supported On: IBM System x
Incremental Interoperability: - None
Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu
Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x
Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup
Firmware Version: 1.1.21.9 Supported On: IBM System x
Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics
Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.4 Latest Driver Version: 3.2.4.0 Document Updated: 11/11/2013 Product: Brocade FC HBA / FCoE CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.4.0 New Features and Feature Enhancement: - Support for RHEL5.10 and RHEL6.5
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
Version 3.2.0.0 New Features and Feature Enhancement: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Fixes and Enhancements: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Version 3.1.0.0 Key features and enhancements supported for the software release 3.1.0.0 include the following:
New Features: - D-port support between Brocade 16Gb HBAs and Brocade 16Gb FC switch platforms with FOS v7.0.1 and later releases - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage - Performance enhancements in Ethernet drivers - Technology Preview support of 1860 HBA on Power PC architecture
Fixes or Enhancements: - Resolved an issue where HCM Agent may not start if BR1860 adapter is configured in NIC mode. - Improved stability with Hyper-V and Teaming configurations. - Resolved I/O errors when running traffic with Brocade HBAs(models 415, 425, 815, 825, and 804), if the server’s PCI max read request size is configured to be 2K or greater with PCI Gen2x8.
Version 3.0.0.0 Fixes and Enhancements: - Added support for Brocade 1860 AnyIO Fabric Adapter (User configurable port mode - FC or NIC or CNA) - Added Fibre Channel 16G Support - Enabled Fabric Assigned Address in Fibre Channel Fabric - Added PF based Virtualization – vHBA - Enhanced CLI, HCM GUI and CIM support in inbox drivers. - Added PF based Virtualization - vNIC - Added iSCSI over DCB Support - Added Multiple Tx Priority Queues Support - Added SNMP Support
Version 2.3.0.3 Fixes and Enhancements: - Enhanced SNIA API to report port speed of 4 and 8Gbps in SNIA format. - Enhanced XIV array interoperability that addresses a data integrity corner case. - Enhanced the transmit path handling in Linux Network Driver to avoid a corner case that could lead to transmit path stall. - Enhanced the Linux Adapter Software installer script to update the initrd with the correct name even when there are multiple copies of the OEM specific initrd(s).
Version 2.3.0.0 Enhancements: - Enabled HP DL120 server to support Boot over SAN with two Brocade HBAs installed. - Improved network driver CPU and performance optimization. - Enabled automated target and LUN discovery of enterprise HDS storage once LUN masking has occurred. - Improved Tivoli interoperability to meet device display requirements.
Version 2.2.0.1 Added capability to handle ADISC frames. Unhandled ADISC use can cause SAN boot failure when booting from IBM storage array.
Version 2.2.0.0 Adds support for bootcode updates to Bladecenter 10G Converged Network Adapters
Version 2.1.0.0 Adds support for bootcode updates to 10G Converged Network Adapters
Version 2.0.0.0 Initial release for 4/8G FC HBAs brcd_dd_fc_bfa-3_2_4_0_rhel5_32-64_chg
ServeRAID m5115 SAS/SATA Controller Firmware Update for Linux
Adapters Supported: ServeRAID M5115 SAS/SATA Controller for IBM Flex System (90Y4390)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 23.22.0-0024 - Non-Critical ------------------- Enhancement(s): - Display the Native Command Queuing (NCQ) enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI. Fix(es): - Disable PI CRC checking when the drive is not initialized during a CC. - Increased the SuperCap learn time out value for 2GB TMM-B solution. - Fixed an issue for 2GB memory modules where SuperCap does not get connected to the controller and hence cache offload fails. - Fixed an issue where cache policy of virtual drives(VD) does not change to write through(WT) mode even after detecting a bad supercap. - Fixed an issue where a RAID configuration created with physical disks in powersave mode could be losted after rebooting the system. - Fixed an issue where an invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive. - Fixed an issue where the system is not allocating memory correctly when MR and iMR controllers are in the same system. - Fixed an issue where deep learn does not start immediately when the relative state of charge (RSOC) is just equal to 95%. - Fixed an issue where performing a re-key operation in external key management (EKM) mode without doing a reboot, and then switching to local key management Mode(LKM) results in the Firmware logs showing that a drive security key was created but HII says the key is incorrect. - Fixed an issue where on a local key management (LKM) enabled controller, the user is asked to enter the security key to unlock and import a foreign drive, which is locked and has external key management (EKM) enabled.
Version 23.16.0-0027 - Critical ------------------- Fix(es): - Addressed data exposure issue when using CacheCade - Fixed issue where Supercap shows 0 Capacitance - Fixed iBBU08 and iBBU09 battery issue that caused a VD cache policy to remain in write-through mode after a manual relearn - Fixed iBBU08 and iBBU09 battery issue that caused a VD cache policy to periodically toggle between write-back/write-through mode - The limits for iBBU08 and iBBU09 battery charging were not updating properly in a learn cycle - Ensures a single supercap pack is not supported on 2GB memory module. - Resolves a firmware crash seen while doing continuous sas cable pulls. - Ensures OpROM loads even if segment address is 0xC0000. - Fixed an issue where the adapter is running iMR machine checking after requesting host memory. - Fixed an issue where HII does not allow the user to make use of the remaining free capacity to configure additional VD for R50/R10. - Fixed an issue where an HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option. - Fixed and issue where Windows cannot install without a VGA device on board. - Fixed and issue in EFI WebBIOS were consistency check is still shown in progress after 1 PD is removed from a R1 array.
Version 23.12.0-0016 - Suggested ------------------- Fix(es): - Added isync to prevent speculative execution while memory is being allocated. - Delayed enablement of POM until AFTER valid memory range is provided by host system.
Version 23.12.0-0011 - Suggested ------------------- Enhancement(s): - Changed BIOS check to determine if running in HAMR, in order to ensure nothing gets broken when user has an iButton which is not programmed. - Changed controller status for safe mode to show controller status as safe mode and disable debug message logging in serial port.
Fix(es): - Addressed an issue where deeply discharged Cache Vault Power Modules would be prematurely be marked as failed. - Fixed an issue where HII hangs when trying to enter configuration management while in safe mode. Changed the safe mode warning message as below: "Controller is running in safe mode. Safe mode is used for diagnostic purposes only. Limited operations such as Configuration Preview, Clear Configuration and View/Change Controller Properties are allowed in this mode. Other operations such as Create Configuration, Import and Clear Foreign Configurations are not allowed. To exit safe mode, correct the fault, and reboot your computer." - Fixed an issue where having more than three adapters results in a calculation error for the offset to store physical disk info for fourth adapter, due to BIOS not clearing upper byte of AX (that is AH which is containing some non zero value). - Fixed an issue where the Wrong spanned drive group size is displayed by WebBIOS (Ctrl-H).
Version 23.7.1-0010 - Suggested ------------------- Fixes: - Fix an issue related to the where the TSOC (EEPROM) is not able to read or write from the firmware which will result in the message "Incompatible secondary iButton present." - Fix a HII broswer issue where Cachecade virtual drive can be selected as a boot device. - Fix a HII broswer issue where the user is unable to clear the controller configuration when there are no drives attached. - Fix an issue where the BIOS doesn't display the RAID level and VD size correctly at BIOS POST.
Version 23.7.1-0009 - Suggested ------------------- Fixes: - Fixed an issue where SoH is bad after a learn cycle but iBBUI shows good status. - Fixed an issue where hi-temp warning was not being displayed.
Version 23.7.0-0029 - Suggested ------------------- Enhancements: - Added support for Cache Cade 2.1 - Added Support for PI Drives
Fixes: - Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup. - Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive - Added a check for the presence of PD before writing the data arms of a protected LD during BGI. - Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS. - Fixed an issue with USB Cacheoffload restore fails after multiple power cycles onServeRAID M51xx controllers. - Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data. - Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash. - Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds. - Fixed background initialization watermark conversion to PD LBA. - Fixed write protected R1E data arms during initialization. - Fixed an issue where MR firmware crashed while discarding pinned cache. - Fixed an issue where a dirty LD dependency information of SSD pd has stale entries. - Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd - Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset. - Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe. - Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM. - Fixed an issue where the firmware was wrongly adding puncture entries. - Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table. - Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event. - Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events. - Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled. - Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value. - Fixed an issue in which a Patrol Read may not start under certain conditions. - Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved. - Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero. - Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU. - Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed. - Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running. - Fixed an issue where CC stops progressing on a R6 VD with media errors. - Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test). - Fixed an issue where controller features are lost if RAID Key was not detected. - Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering. - Fixed an issue where 'Native configuration is no longer supported' message in post. - Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low. - Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Version 23.2.1-0043 ------------------- -Initial release ibm_fw_sraidmr_5115-23_22_0-0024_linux_32-64_chg
Change History - 3.11af
Package Version 3.11af.c Only change with ".c" is with file naming. 05/13/2014
Change History - 3.11af.a 03/30/2014 ======================================================================================== Firmware
* Added check invalid LUN when configuring boot target (ER105664). * Added support for P3P * Removed Execution Throttle Option From CTRL_Q
Previous versions:
Version : 7.01.00 Date : 01/09/2014
Version : 7.00.00 Date : 07/22/2013
Version : 5.10.00 Date : 06/12/2013 * Added check invalid LUN when configuring boot target * Added support for P3P * Removed Execution Throttle Option From CTRL_Q * Fix issue that cause external looback to fail (er71773). Added support for Hilda
Version : 5.07.02 Date : 10/23/2012 * Fix Task Management IOCB type 14h completion with dma error status. * Fix an issue where HBA would constantly ISP reset if switch in transparent mode but no upstream switch
Version : 5.07.00 Date : 5/17/2012 * New Feature: Firmware sends Report ID Acquired IOCB Type 32h upon Flogi failure. * New Feature: Firmware reports NportHandle, WWPN and WWNN of remote port in Report ID Acquired IOCB Type 32h for N2N connection topology. * Fix firmware not logging out SNS port (PID=0xFFFFFc) while processing implicit Logout all request * EP Device Only: Fix advertised BB_Credits not increasing with additional receive credits option set. * Target Mode: Fix firmware fatal error seen while aborting an exchange. * Fix firmware failing request to disable multiple virtual ports using iocb type 30h. * Fix Loop port bypass (40h) and loop port enable (41h) mailbox commands not working correctly. * FC-VI only: Fix disconnect request iocb timeout. * T10 Only: Fix firmware reporting DIF errors while running multi sequence, T10-DIF enabled IO’s with protection mode set to DIF- Remove. * Fix firmware fatal error while running T10-DIF enabled IO’s with protection mode set to DIF-Remove. * Fix incorrect reporting of discarded and dropped frame count in mailbox command 6Dh. * Add support for programming page and payload length fields in TPRLO response frame.
Version : 5.06.05 Date : 4/26/2012 --Initial Release
Version : 2.14 Date : 05/07/2013 *Added check invalid LUN when configuring boot target (ER105664). *Added support for P3P *Fix issue that cause external looback to fail (er71773)
Version : 2.13 Date : 7/31/2012 *Added code code to check for non-EDC HBA's in CTRL-Q utility. *Fixed bug in EDC update code
Version : 3.20 Date : 05/07/2013 * ER102374: Display Product-ID string in VPD area during initial selection. * ER94574: Fix stack bug in .adatper-info, found in blade hotplug test by efcode
Version : 3.19 Date : 7/31/2012 * Add check for MBAR2 (Multi-Queue memory) and create reg property if it exists. * Make validate-nvram silent. Print messages only if debug-flash?(x1000) is set. * Added dynamic sizing of the BAR registers at probe-time for reg property. * Remove dis-exp (disable-exprom) in ena-reg-acc. Causes problem on SPARC T3-1B. * Fix bugs in search of Card-Type-Lists for SSDID when flashing w/find-ilt-code. * Change oem property to QLogic or Oracle, and manufacture property to QLogic. * Added SSDID check to set-edc-config. * Stripped ISP2400 & SUN specific code using #ifdefs to reduce IBM size by .5KB * Added EDC FW area in Flash and added write-sfp and read-sfp mailbox commands * Added set-edc-config, edc-update?, and edc-present! words to nvram.fth.(IBM) * Added check-edc-load and load-edc-fw words to init-isp.fth..
IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ********************************************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to B568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
*******************************************
Version 1.11.01 (Non-Critical) - Fixed issue where hard disk drives may not be detected in configurations with multiple Emulex adapters.
See Verion 1.11 for Hard Disk Drive support, firmware levels, and respective change History.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
=========================================== Version 1.10 (Critical)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
=========================================== Version 1.09 (Critical)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) Retain Tip H196899 MBE2073RC, MBE2147RC to SC16 (Critical) Retain Tip H196899 Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off
*******************************************
Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
The following is a list of drives and the firmware that they will be checked for and updated to as necessary.
This package includes new updates to drives with product ID strings of:
SAS 3.5" --------------
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code releases to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
*******************************************
Version 1.05
The following is a list of drives and the firmware that they will be checked for and updated to as necessary.
This package includes new updates to drives with product ID strings of:
SAS 2.5" (SFF) -------------- ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled. NOTE: This is the first code for the ST9xxxx52SS and ST9xxxx02SS drives to be included in a hard drive update package. It is an update from the code that is shipped with the drive.
MBD2xxxRC to SB14 - Initial release
SAS 3.5" -------- ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 2.5" --------- WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD -------------- STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663.
NOTE: This is the first code for the GBRLBxxxxx drives to be included in a hard drive update package. It is an update from the code that is shipped with the drive.
*******************************************
Version 1.04
The following is a list of drives and the firmware that they will be checked for and updated as necessary.
This package includes new updates to drives with product ID strings of:
SAS 2.5" (SFF) -------------- CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller.
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller.
SAS 3.5" -------- MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller.
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632. - Fixes a hang condition during failover operation on a BladeCenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixed an issue where a drive may prematurely report a PFA trip.
GNAxxxxxx to BH0J - Fixed an issue where a drive may prematurely report a PFA trip.
SATA 3.5" --------- ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632. - This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx to 02.03B04 - Fixed incorrect VPD data.
SATA 2.5" --------- WD3000xxxxx to 04.04V04 - Fixed a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spin up of the drive may be overwritten, rendering the drive inoperable on a subsequent warm or cold system reboot. - Fixed a bug with an internal timer that may cause a drive to go offline when used in a non-RAID environment.
SATA 2.5" SSD ------------- STEC MACH8 IOPS to 2103 - Initial Release
*******************************************
Version 1.03
Added the capability to update SAS and SATA drives online under Windows or Linux. This capability is only supported if the drives are attached to one of the following SAS adapters: - IBM ServeRAID MR10k SAS Controller - IBM ServeRAID MR10i SAS Controller - IBM ServeRAID MR10M SAS Controller - IBM ServeRAID MR10il SAS Controller - IBM ServeRAID MR10is SAS Controller - MegaRAID 8480 SAS Controller - IBM ServeRAID BR10i SAS Controller - IBM ServeRAID BR10il SAS/SATA Controller - IBM SAS HBA - IBM SAS Expansion Card (CFFv) for IBM BladeCenter - IBM SAS Connectivity Card (CFFv) for IBM BladeCenter - Onboard LSI 1064 SAS controller (2MB only) - Onboard LSI 1068 SAS controller - Onboard LSI 1078 SAS controller
This package includes new updates to drives with product ID strings of:
SAS 2.5" (SFF) -------------- ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a BladeCenter-S chassis. - Picked up the latest network roll of firmware fixes to address some unexpected system hangs.
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a BladeCenter-S chassis. - Picked up the latest network roll of firmware fixes to address some unexpected system hangs.
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5" -------- VPBAxxxxxx to A496 - Added support for JS2x Blades in a BladeCenter-S chassis.
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a BladeCenter-S chassis. - Picked up the latest network roll of firmware fixes to address some unexpected system hangs.
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47.
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5" --------- ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV - Initial release
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV - Initial release
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD ------------- GBRL001xxx, GBRL0031xxx to 4.14 - Corrects intermittent hangs during operations.
Firmware Version: 10.2.261.36 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - FRU VPD fields are now properly populated on CN4054 and CN4054R - Fixed UE resulting slow boot at UEFI splash screen and NIC devices removed - When using VMQ with Windows Server 2012 or 2012R2, the user may experience VM connectivity loss, packet drops, system hangs, inability to shutdown VMs and possible system crashes on shutdown. The complete solution also requires 10.2 based Windows NIC driver.
Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console)
Known Issues: - Server hangs at "Scan for Fibre Devices", when port disable/enable performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do a reboot is needed.(159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159505)
- Intermittently, 255 vPorts can not be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!". There is no known workaround other than to reduce the number of configured vPorts.(155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system.(159121)
- PXESelect showing incorrect MAC address, bandwidth & SVID values. This bug is a cosmetic issue and only impacts PXESelect. The values which are not displayed correctly in PXESelect can be viewed in UEFI, OCM, and on the switch.(151140)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here.(159226)
- "Configurations have changed" message seen in UEFI setup screen when no changes were made. This pop-up can be ignored and will be fixed in a future code release.(159086)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target.(157137)
- FCoE VLAN ID is being displayed incorrectly as hexadecimal in UEFI menu. This is a cosmetic issue only. The correct VLAN is properly assigned, so there is no functional impact. The actual VLAN ID can be observed elsewhere. (159561)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations(158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware Version: 10.0.803.13 Supported On: IBM System x
Problems Fixed: - IBM Feature on Demand for storage keys now works with Optimized Boot enabled - Link detection time improved from ~70 secs on DAC cable insertion/removal
Incremental Interoperability: - Unified Fabric Protocol on IBM System x Servers
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.281.26 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - CN4054 VPD is not valid during/after IMM flash - Links go down after 497 to 498 days in VMWare - Send 'link down' to switch if UE occurs on ASIC
Incremental Interoperability: - Emulex Dual Port 10GbE SFP+ VFA IIIr for IBM System x - Emulex Dual Port 10GbE SFP+ Embedded VFA IIIr for IBM System x
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.281.21 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - OCe10 VFA CNAs stuck in "Switch Independent Mode" - Port Identification fails on Port 1 under uEFI menu for PCIe rack VFA
Incremental Interoperability: - IBM Flex System CN4054R 10Gb Virtual Fabric Adapter - IBM Ivy Bridge CPU Based Servers
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.281.8 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - HW iSCSI offload is now supported in UFP Mode (UFP limited to IBM Flex) - Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs. - When using Config Patterns with virtual MACs the bandwidth settings are are intermittently reset after some number of server reboots.
Incremental Interoperability: - IBM Flex System Fabric SI4093 System Interconnect Module - IBM Flex System EN6131 40Gb Ethernet Switch - IBM Flex System x222 10Gb Virtual Fabric LOM - SLES 11.3 on IBM System x and BladeCenter - Complete NIC/iSCSI/FCoE support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers. - Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers. - When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.166.7 Supported On: IBM System x and BladeCenter
Problems Fixed: - When connected to Cisco Nexus 4k and 5k switches, the virtual link may not recover on a switch port bounce (shut/no shut) in an ESXi environment. A switch port re-bounce will recover the link. - When connected to Cisco Nexus 4k and 5k switches, OneCommand Manager reports CRC's and there is poor network performance in an ESXi environment
Incremental Interoperability: - ASU/Config Pattern configuration for iSCSI and FCoE (BE3) - UFP for iSCSI (BE3) - Support for using 10Gb ports with legacy 1Gb switches installed in a BladeCenter-S chassis or MSIM/MSIM-T expansion units in a BladeCenter-H or -HT chassis - Update Express System Packs now support Linux errata kernels - ESXi 5.1
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers. - Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers. - Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs. - When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware Version: 4.4.180.3 Supported On: IBM Flex
Problems Fixed: - 10Gb ports intermittenly linking at 1Gb speed with the IBM Flex System Fabric EN4093/EN4093R 10Gb Scalable Switch. - Switch Configuration after an erase configuration is not reflected after reboot - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - When adding an iSCSI hardware target in UEFI through discovery login, the boot target setting is ignored.
Interoperability since previous release: - UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility - IBM Universal Configuration Manager for Ethernet - IBM Unified Fabric Protocol - Ability to assign Switch Agnostic VLAN IDs without intermediate reboot - Changes to Personality or Multichannel in PXESelect allows further changes to be made w/o reboot - Support for IBM Flex System Fabric CN4093 10Gb Converged Scalable Switch
Known Issues: - HW iSCSI offload is not currently supported in UFP mode
Firmware Version: 4.1.422.8 Supported On: IBM Flex
Problems Fixed: - PHY Loopback fails on 10G ports - RH 6.2 and W2k8 servers crashed after shut/no shut the switch port with FCoE connection and 50 vlans configured - DSA: NIC physical loopback test fails in Command and GUI mode - Firmware update fails to update all VPD Code Level fields - DCBX does not converge with FW 4.1.422 on Cicso 5k.
Interoperability Since Previous Release: - Support for IBM Flex System x440 10Gb Virtual Fabric LOM
Firmware Version: 4.1.422.0 Supported On: IBM Flex
Problems Fixed: - SR IOV: Unable to ping IPV6 from DUT VF to Peer VF - Reading VPD from BE3 timesout making SR IOV fail in newer kernels - 1Gb devices are being suppressed by kernel during the PCI probe in SLES11 SP2 - MAC Loopback fails when Mgmt Adapter Creation fails - Failure of MAC loopback test after firmware update and warm reboot - Suppress efat dump mailbox commands in the efat dump log - Running ethtool with BE3 takes longer than expected after cable pull - Out of Order CQEs - TRACE_LOG function not printing the messages for some of the VF's - esx4/5 issue. svc target cannot be configured properly - RSCN is not generated by switch when a driver restarts - Port Link stays up even after switch removed
Interoperability Since Previous Release: - Support for IBM Flex System EN4054 4-port 10Gb Ethernet Adapter - Support for IBM Flex System CN4054 10Gb Virtual Fabric Adapter - Support for IBM Flex System x240 10Gb Virtual Fabric LOM - Support for IBM Flex System Manager 10Gb Virtual Fabric LOM
Firmware Version: 4.2.433.3 Supported On: IBM System x and BladeCenter
Problems Fixed: - Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup. - Under high network stress, NMI errors can be seen with x3690 X5 and x3850 X5 - 10GbE ports running at 1GbE speed 10% below wirespeed at certain block sizes. - Unable to perform PXE boot with LPVID assigned to vNIC interface - 1Gb ports of HS23 do not handle tagging properly if multichannel mode enabled (pnic ok). Note: ESX driver patch also required. - Port flapping link after FW upgrade and "reboot" when connected to 10Gb PTM module (DAC)
Interoperability Since Previous Release: - Support for Emulex Virtual Fabric Adapter Advanced (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM System X
Known Issues: - All 10Gb KX4 ports must be used with 10Gb switches. They will not link at 1Gb. This applies to HS23 LOM and IBM BladeCenter VFA adapters only. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456
Firmware Version: 4.2.412.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - All VFS on Port 1 on optional Card unreachable from outside the host (x3750 M4) - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - 1Gb ports on HS23 LOM not able link up with IBM ICPM (FRU part 44W4486) in BCS chassis - Performance issues with specific DAC cables and SND top of rack switch
Interoperability Since Previous Release: - UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility
Known Issues: - All 10Gb ports must be used with 10Gb switches. They will not link at 1Gb. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456 - Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup.
Firmware Version: 4.1.455.6 Supported On: IBM System x and BladeCenter
Problems Fixed: - Fixed an issue where ASIC randomly hangs losing network connectivity when certain commands are sent from the host. Resulting behavior varies between OS's (Yellow bangs in Windows, PSOD in VMWare) - PHY Loopback fails on 10G ports - UE and hang on LOM or Robalo when powering off Janice in UEFI or PXESelect - Loopback on HS23 now functional in DSAp - DCBX does not converge with firmware on a FCoE fabric - Control C Broken on BE2 - 7 second delay in GET_CARD_ATTRIBUTES command - Emulex VF adapter FCoE link lost on VMware 5.0 - flow control set for 10G Base T phys for autonegotiation - Dynamic link update is not working with NIC UEFI driver - Remove unused definitions in UEFI NIC - Emulex driver expects that the Login Options field be zero - "map r" displays a iSCSI BLK device when no LUNs presented - "X/x Exit without save" does not work as expected - Display proper description as part of EFI Driver Model Related Information - Intermittent "Configuration changed. reset to apply it now?" - Garbled output being displayed at the LUN configuration section. - All Emulex Configuration settings get lost after a reset - Perform additional checks when no Luns are mapped to the target - CHAP name only accepts 6 to 10 characters - Hii ???iSCSI Initiator Configuration??? showing old version screen - iSCSI name is case sensitive - iSCSI HII allows user to select first 8 LUNs as bootable. - iSCSI Boot Enable/Disable option should be port specific - LUN Configuration shows LUN 0, even if no LUNs presented to initiator.
Interoperability Since Previous Release: - Support for Emulex Virtual Fabric Adapter Advanced (CFFh, 2+2) for IBM BladeCenter
Firmware Version: 4.1.334.47 Supported On: IBM System x and BladeCenter
Problems Fixed: - NCSI transmit workaround for IBM - Issues with data reporting when BOFM enabled - Improved network performance throughput - Issues with IBM Management network performance - Logical link status for IBM mezz card shown as 'N/A' - Serial Over LAN fails when more than one blade installed with a single switch - Removed UEFI menu items for unsupported functions on a port - Issues with diagnositics in virtual NIC/UMC mode - Issues with MAC and PHY loopback on OneConnect devices - Several issues with FCoE on some OEM fabric switches
Interoperability Since Previous Release: - Support for HS23 Virtual Fabric LAN on Motherboard - Support for VFA III (95Y3762, 95Y3768), 90Y6456 - Support for IBM's Features on Demand (FOD) - Formal support for SR-IOV
Firmware Version: 4.0.1062.0 Supported On: IBM System x and BladeCenter
Problems Fixed: - iLab Tucson - lpfc Device Resets and path failures continue after error inject. - Writes do not complete when running LIP test on BE3 port 2 - IPV6 implementations no longer experience an unrecognized routing type error. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - IPV6 implementations no longer experience an unrecognized routing type error. - Installing Windows 2008 or Windows 2008 R2 on remote iSCSI disks no longer causes the system to hang. - Issues no longer occur when resetting a server configured for multipathing on VMware ESX systems. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - An adapter hardware error no longer occurs when running I/O with LUNs on x86 platforms. - Changing from Convergence Enhanced Ethernet (CEE) to Chassis Internal Network (CIN) and then rebooting no longer fails to link-flap (CIN Fabric Login (FLOGI) now occurs). - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - DCB settings can now be configured. - (iSCSISelect) When enabling DHCP for an iSCSI initiator, the Emulex iSCSI Network Configuration utility now waits approximately 20 seconds to make a DHCP connection before returning control. - (FCoE BootBIOS) FCF CEE parameters for Boot from SAN configuration are now saved properly.
Interoperability Since Previous Release: - Added support for switch-independent multichannel mode. - Added support for IBM Virtual Fabric 10Gb RackSwitch firmware 6.8.1.0. - Added support for IBM Virtual Fabric 10G Switch Module firmware 6.8.1.0. - Added support for Fibre Channel over Ethernet (FCoE) on rack systems. - Added support for iSCSI hardware offload on rack systems. - Added support for Cisco Nexus 5000-series switches.
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.4.1 Latest Driver Version: 3.2.4.1 Document Updated: 04/14/2014 Product: Brocade FC/NIC/CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.4.1 New Features and Feature Enhancement: - Support for 3.2.23.0 inbox drivers
Fixes and Enhancements: - AIM and UCM fix
Version 3.2.4.0 New Features and Feature Enhancement: - Support for RHEL5.10 and RHEL6.5
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.1 Fixes and Enhancements: - Firmware update to address the thermal notification issue
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
Version 3.2.0.0 Release for FC/NIC/CNA
New Features and Feature Enhancement: - Updated code for Brocade 1867 IBM Flex System FC5022 FC Adapter for x22 - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Fixes or enhancements: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Version 3.1.0.1 Release for 16G FC/NIC/CNA
Adapter Features - Updated code for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A
Version 3.0.3.1 Initial release for 16G FC/NIC/CNA
Adapter Features - Initial support for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A brcd_fw_cna_3_2_4_1_linux_32-64_chg
IBM Flex System x240 UEFI Flash Update Version 1.50 (BuildID B2E142A) Change History
Version 1.50 - BuildID: B2E142A (Critical) -------------------------------------------- Problem(s) Fixed: - Incorporated Intel Memory Reference Code (MRC) update 2.0.0.3 - Incorporated Intel Microcode Update (MCU) MED306E4_00000427 - Fixed memory type programming for 64-bit PCI resources on multisocket systems Enhancements: - Added support for Agentless configuration - Enabled RAID link feature on Storage Expansion Node Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.41 - BuildID: B2E136U (Suggested) -------------------------------------------- Problem(s) Fixed: - Incorporated Intel Memory Reference Code updates to support memory chip manfuacturer updates Enhancements: Limitations: - When flashing UEFI from version 1.20 or later down to version 1.1x or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.20. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.40 - BuildID: B2E136T (Suggested) ------------------------------------------- Problem(s) Fixed: - Addressed a problem where more than four Preboot eXecution Environment (PXE) device option ROMs could be loaded even though legacy BIOS code will only support the first 4 devices - Updated high Memory Mapped Input/Output (MMIO) base address to allow use of this memory in VMWare systems Enhancements: - Added support for Intel® Xeon® Processor E5-2600 v2 product family - Added support for Tivoli Key Lifecycle Manager (TKLM) - Added support for Global Partition Table (GPT) Corruption Repair - Added support for security standard NIST 800-131a Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.31 - BuildID: B2E126E (Suggested) ------------------------------------------- Problem(s) Fixed: - Added code workaround for soft shutdown issue on master chips - Updated "Memory Refresh setting" to remove 4x selection to synch up with latest chipset vendor support statement Enhancements: Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.30 - BuildID: B2E126D (Suggested) ------------------------------------------- Problem(s) Fixed: - Incorporated Microcode Update (MCU) M6D206D7_00000710 to address Intel Erratum BT248 for System Resets with 32-bit (PAE Enabled) Guest OS and VT FlexPriority enabled. For more information, refer to IBM RETAIN Tip H21370. - Improved handling of missing values for iSCSI initiator name - Corrected handling of pre-boot serial port redirection settings - Corrected garbled SOL output strings during early phases of UEFI booting - Clarified actions required to effect changes to Trusted Platform Module (TPM) setup - Corrected failure to load some default settings on CMOS battery failure - Improved wording for progress codes and messages - Corrected the order in which UEFI configures Ethernet ports - Improved handling of USB configuration changes - Corrected boot configuration problem Enhancements: - Updated DMI Type 17 support for for new memory devices - Improved support for 32GB memory - Improved general Reliability/Availability/Serviceability support - Added ability to resize PCIE IO base address registers dynamically - Improved handling of memory in high stress application/usage - Added ACPI Firmware First logging support - Added setup capability to select PCIE Config Base below 4GB - Added informational messages when exiting UEFI F1 Setup Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.21 - BuildID: B2E122D (Suggested) ------------------------------------------- Problem(s) Fixed: - UEFI port order change for Emulex UCM support - System hangs at IBM LOGO with Broadcom Dual Runner NIC installed, config manager updated - Optimized memory ECC tracking and reporting Enhancements: - BIOS Setup Power Saving & Performance Options Updates Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.20 - BuildID: B2E120Q (Suggested) ------------------------------------------- Problem(s) Fixed: - Corrected BOFM Configuration errors - Corrected iSCSI setup/configuration problems - Corrected SMBIOS table entry problems - Corrected memory error handling problems - Corrected FOD state transition problems - Corrected ACPI problems - Corrected I/O problems - Corrected Security errors - Corrected Configuration errors - Corrected errors in Setup operations - Corrected RAS problems Enhancements: - Add support for ACPI S3 state - Add support for automatic ROM recovery - Add support for dynamic debug capability - Improve Update Security - Improve Configuration Support - Add common support for OS-4690 Limitations: - When flashing UEFI from version 1.20 or newer to a version earlier than 1.20, a "Boot Configuration Error" message will be logged into the UEFI error log. This error has no impact on the system configuration or operation. No errors are logged when flashing from an earrlier version to version 1.20 or newer. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40E Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.20. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.10 - BuildID: B2E118B (Suggested) ------------------------------------------- Problem(s) Fixed: - Corrected errors in SMBIOS Table Type 9 Slot ID (09h) - Corrected errors in correlating SEL Events with UEFI Auxilliary Data - Corrected problems in setting boot order - Corrected problems in loading pDSA image Enhancements: - Support VLAN - Enable Rank Based PFA Protocol - Reduced the idle power consumption by gating power to unused devices - Added a prompt in setup to save settings after modifying Operating Mode - Added the Embedded Hypervisor as a default boot option Limitations: Dependencies:
Version 1.01 - BuildID: B2E114D (Suggested) ------------------------------------------- Problem(s) Fixed: - UEFI event ID not showing up in logs for double bit memory errors Enhancements: - Add support for LRDIMMS Limitations: Dependencies:
=============================================================================== Emulex FC/FCoE Device Driver for Linux ===============================================================================
Device Driver Version: 10.2.261.0 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - ELS txcmplq list corruption cause crash during error injection
Device Driver Version: 8.2.2.24 Supported On: IBM System x, BladeCenter, and Flex
Problems Fixed: - RHEL 5.8 x86 blade crashes during FCoE failover test - Execution of internal loopback causes a crash - Issue which can cause multipath failover to not work properly
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - IBM Tape unit interoperability - see SSIC for more information
Device Driver Version: 8.2.2.15 Supported On: IBM System x and BladeCenter
Problems Fixed: - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - OXID Reused before RA_TOV without RRQ to recover - Intermittently storage paths will not recover after switch reboot
Device Driver Version: 8.2.1.4 Supported On: IBM Flex
Problems Fixed: - Fixed debug helper routine failed to dump CQ and EQ entries in non-MSI-X mode - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - Fixed boot from san failure when SLI4 FC device presented on the same PCI bus - Fix ABTS recovery to be FC spec compliant - Fixed not reporting logical link speed to SCSI midlayer when QoS not enabled - Fix performance problem in pt2pt mode - Fixed SCSI host create showing wrong link speed on SLI3 HBA ports - Update text for misconfigured port messages - Fix discovery bug when swapping cables
Interoperability since previous release: - No new interoperability
Device Driver Version: 8.2.0.145 Supported On: IBM System x and BladeCenter
Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service
Interoperability since previous release: - RHEL6.3 GA Kernel
Device Driver Version: 8.2.0.134 Supported On: IBM System x and BladeCenter
Problems Fixed: - Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix bug with mailbox handling of REG_VFI and cable pull - Used PCI configure space read to flush PCI function reset register write - Update copyright date for files modified in 2012 - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fix port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Fix KERNEL allocation while lock held - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Fix for FDISC failures after firmware reset or link bounce - Limit what management ELS and CT commands can be issued according to latest management specification - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Added driver logs in area of SLI4 port error attention and reset recovery
Device Driver Version: 8.2.0.122 Supported On: IBM System x and BladeCenter
Problems Fixed: - Fix bug with driver returning the wrong ndlp - Fix driver behavior when receiving an ADISC - Fixed PCI loopback diagnostic test through hbaCmd on SLI4 port failure - Fixed unbounded firmware revision string from port caused the system panic - Fix driver does not reset port when reset is needed during - Changed SLI4 FC port internal loopback from outer serDes to inner internal - Fix ELS FDISC failing with local reject / invalid RPI - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtain link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed system panic duringEEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed logging mailbox error log messages during SLI4 FW download using HbaCmd - Fixed illegal state transition during driver unload - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix bug with driver erroneously logging a kernel error message - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Add loop support for sli4 fc - Fixed OCM failing COMN_READ_OBJECT and COMN_WRITE_OBJECT mailbox pass- through - No longer read fcoe parameters if board is not fcoe - Added restore state and error log when sysfs board_mode attribute access failed - Added support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Added support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS.Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when Lancer fails to initialize - Fixed fcpi param length when not using an sgl - Fix virtual fabrics bit set in FLOGI incorrectly - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Fix kernel build warnings - Modify WQ handling to use entry_repost - Added a sysfs attribute "protocol" to report SLI4 port link protocol type - Added SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Added structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fix a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Add new check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Moved fcp policy structs - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fixed fcp underrun reporting - Fix sysfs lists fabric name for port that has been disconnected from fabric - Added support for policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Fixed compiler warningdue to uninitialized local variable - Added proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed incomplete scsi messages displayed - Change log message in lpfc_sli_set_dma_length() - Completed missed FCF priority failover - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix driver firmware update to match new firmware image format - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed crash when aborting els IOs - Fixed handling of CVL for vports - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Added fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed hbacmd listhbas took very long time when remote initiators present in zone - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - iDiag changed command structure data array indexing by using macro defines - Ported iDiag pass-through multi-buffer mbox command capture and dump extension - Ported new SLI4 FC device loopback test and link diagnostic test supports - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Add sysfs logging when writeable parameters are changed - Fixed new ASIC device-mgmt SYSFS pass-through failed multi-buffer fw download - Fixed memory leak due to failure to release mailbox command when completed - Brought debugfs accessing new ASIC extents information into the iDiag framework - Added wait for SLI port status register for readyness following firmware reset - Consolidated duplicating macro definitions - Implement debugfs support for resource extents - iDiag method for read write bitset bitclear access to new ASIC control registers - Fixed failure in pass-through mbox command with multiple number of large buffers - iDiag method for endian explicit dumping at iussue SLI4 mailbox command routine - iDiag ported debugfs method for dumping mbox from SLI4 issue mbox cmd routine - Added request for PCI funndamental reset to support EEH recover on P7 platform - iDiag ported debugfs inline mailbox command capture and dump utility - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Fix EEH recovery so state is saved after every PCI reset for SLI4 - Moved INIT_LIST_HEAD to inside of lpfc_mgmt_issue_sli_cfg_ext_mbox routine - New ASIC device management pass-through mbox extension with multi-buffer support - Fix FC Port swap on SLI3 adapters - Fixed Virtual link loss during Face plate failover test - Fix vpi initialization in lpfc_init_vfi - Added driver capability of reseting new ASIC firmware and device from sysfs entry - Added capability of inducing new ASIC firmware dump obj file to flash filesystem - Add firmware upgrade code to driver - Added 100ms delay before driver action following IF_TYPE_2 function reset - Fragment ELS and SCSI SGE lists based on Extent regions - Fixed potential missed SLI4 device initialization failure conditions - FixedBack to back Flogis sent without a logo - Add model names for new hardware - Fix bug with lpfc driver not updating the wwnn and wwpn after a name change - Set the maximum SGE size to 0x80000000 when HBA does not have any restriction - Fix SLI3 and non-NPIV crashes with new extent code - Fix CT command never completing on Big Endian system - Refactor lpfc_sli4_alloc_extent some more - Restore SLI4_PARAMETER mailbox can fail as nonerror functionality - Do not post RPI Headers to SLI4 port that support extents - Framework for new ASIC device management multi-buffer mbox passthrough support
=============================================================================== Emulex 16GB FC Firmware Package ===============================================================================
Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex
Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change
Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console)
Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504)
Firmware Version: 1.1.43.21 Supported On: IBM System x
Incremental Interoperability: - None
Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu
Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x
Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup
Firmware Version: 1.1.21.9 Supported On: IBM System x
Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics
Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches
tg3: Poll cpmu link state on APE + ASF enabled devices
On ASF enabled devices where the mgmt firmware runs on the application processing engine, there is a race between the tg3 driver processing a link change event and the ASF firmware clearing the link changed bit in the EMAC status register. This leads to link notifications to the driver sometimes getting lost.
Poll the CPMU link state as a backup for the normal interrupt path update if ASF is enabled.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Set the MAC clock to the fastest speed during boot code load
On the 5717, 5718 and 5719 devices, the bootcode runs slower when any port doesn't have a link due to clock speed slowing down as part of the link-aware feature. This leads to the driver timing out waiting for the bootcode signature.
This patch overrides the clock policy to the highest frequency just before reset and restores it after the bootcode is up.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit e565eec31d9d5b1024311564f6536162df951de4 Author: Michael Chan Date: Fri Jan 3 10:09:12 2014 -0800
tg3: Add unicast filtering support.
Up to 3 additional unicast addresses can be added to the perfect match filter table.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit f022ae62dd84425192b27100dcf907019f654d02 Author: Michael Chan Date: Fri Jan 3 10:09:11 2014 -0800
tg3: Refactor __tg3_set_mac_addr()
so that individual MAC address filter entries can be set.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
tg3: Expand 4g_overflow_test workaround to skb fragments of any size.
The current driver assumes that an skb fragment can only be upto jumbo size. Presumably this was a fast-path optimization. This assumption is no longer true as fragments can be upto 32k.
v2: Remove unnecessary parantheses per Eric Dumazet.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Initialize REG_BASE_ADDR at PCI config offset 120 to 0
The new tg3 driver leaves REG_BASE_ADDR (PCI config offset 120) uninitialized. From power on reset this register may have garbage in it. The Register Base Address register defines the device local address of a register. The data pointed to by this location is read or written using the Register Data register (PCI config offset 128). When REG_BASE_ADDR has garbage any read or write of Register Data Register (PCI 128) will cause the PCI bus to lock up. The TCO watchdog will fire and bring down the system.
Signed-off-by: Nat Gurumoorthy Acked-by: Michael Chan Signed-off-by: David S. Miller
tg3: Expand multicast drop counter miscounting fix to 5762
commit 4d95847381228639844c7197deb8b2211274ef22 - "tg3: Workaround rx_discards stat bug", added a workaround for miscounted statistics for multicast packets. This fix needs to be applied to the 5762.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Add flag to disable 1G Half Duplex advertisement
Some link partners have issues if the non-standard 1G half duplex is advertised. This patch adds support for an nvram setting to disable the advertisement.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
rxbds_empty is an informational statistic signifying that a ring full condition was observed. It does not mean an overflow has occurred.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 8496e85c20e7836b3dec97780e40f420a3ae2801 Author: Rafael J. Wysocki Date: Sun Dec 1 02:34:37 2013 +0100
PCI / tg3: Give up chip reset and carrier loss handling if PCI device is not present
Modify tg3_chip_reset() and tg3_close() to check if the PCI network adapter device is accessible at all in order to skip poking it or trying to handle a carrier loss in vain when that's not the case. Introduce a special PCI helper function pci_device_is_present() for this purpose.
Of course, this uncovers the lack of the appropriate RTNL locking in tg3_suspend() and tg3_resume(), so add that locking in there too.
These changes prevent tg3 from burning a CPU at 100% load level for solid several seconds after the Thunderbolt link is disconnected from a Matrox DS1 docking station.
Signed-off-by: Rafael J. Wysocki Acked-by: Michael Chan Signed-off-by: David S. Miller
commit 7260899bde50cbe84bdf0a15b5642e2c3b03db32 Author: Ben Hutchings Date: Mon Nov 18 22:59:43 2013 +0000
tg3: Implement the SIOCGHWTSTAMP ioctl
While we're doing this, fix the error code for SIOCSHWTSTAMP ioctl on non-timestamping hardware.
Compile-tested only.
Signed-off-by: Ben Hutchings
commit 58b187c68d91b54b82f6fd267ee3346ed8770655 Author: Ben Hutchings Date: Thu Nov 14 00:40:56 2013 +0000
tg3: Validate hwtstamp_config completely before applying it
tg3_hwtstamp_ioctl() should validate all fields of hwtstamp_config before making any changes. Currently it sets the TX configuration before validating the rx_filter field.
Compile-tested only.
Signed-off-by: Ben Hutchings Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 85aec73d595b8847f9c4ea571deb127913f0d508 Author: Ivan Vecera Date: Wed Nov 6 14:02:36 2013 +0100
tg3: avoid double-freeing of rx data memory
If build_skb fails the memory associated with the ring buffer is freed but the ri->data member is not zeroed in this case. This causes a double-free of this memory in tg3_free_rings->... path. The patch moves this block after setting ri->data to NULL. It would be nice to fix this bug also in stable >= v3.4 trees.
Cc: Nithin Nayak Sujir Cc: Michael Chan Signed-off-by: Ivan Vecera Acked-by: Michael Chan Signed-off-by: David S. Miller
commit d458cdf712e0c671e8e819abb16ecd6e44f9daec Author: Joe Perches Date: Tue Oct 1 19:04:40 2013 -0700
net:drivers/net: Miscellaneous conversions to ETH_ALEN
Convert the memset/memcpy uses of 6 to ETH_ALEN where appropriate.
Also convert some struct definitions and u8 array declarations of [6] to ETH_ALEN.
Signed-off-by: Joe Perches Acked-by: Arend van Spriel Signed-off-by: David S. Miller
tg3: add support a phy at an address different than 01
When phylib was in use tg3 only searched at address 01 on the mdio bus and did not work with any other address. On the BCM4705 SoCs the switch is connected as a PHY behind the MAC driven by tg3 and it is at PHY address 30 in most cases. This is a preparation patch to allow support for such switches.
phy_addr is set to TG3_PHY_MII_ADDR for all devices, which are using phylib, so this should not change any behavior.
Signed-off-by: Hauke Mehrtens Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Commit 989038e217e94161862a959e82f9a1ecf8dda152 ("tg3: Don't turn off led on 5719 serdes port 0") added code to skip turning led off on port 0 of the 5719 since it powered down other ports. This workaround needs to be enabled on the 5720 as well.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit ede23fa8161c1a04aa1b3bf5447812ca14b3fef1 Author: Joe Perches Date: Mon Aug 26 22:45:23 2013 -0700
drivers:net: Convert dma_alloc_coherent(...__GFP_ZERO) to dma_zalloc_coherent
__GFP_ZERO is an uncommon flag and perhaps is better not used. static inline dma_zalloc_coherent exists so convert the uses of dma_alloc_coherent with __GFP_ZERO to the more common kernel style with zalloc.
Remove memset from the static inline dma_zalloc_coherent and add just one use of __GFP_ZERO instead.
Trivially reduces the size of the existing uses of dma_zalloc_coherent.
Realign arguments as appropriate.
Signed-off-by: Joe Perches Acked-by: Neil Horman Acked-by: Jesse Brandeburg Acked-by: Jeff Kirsher Signed-off-by: David S. Miller
While EEH error happens, we might not have network device instance (struct net_device) yet. So we can't access the instance safely and check its link state, which causes kernel crash. The patch fixes it.
EEH: Frozen PE#2 on PHB#3 detected EEH: This PCI device has failed 1 times in the last hour EEH: Notify device drivers to shutdown (NULL net_device): PCI I/O error detected Unable to handle kernel paging request for data at address 0x00000048 Faulting instruction address: 0xd00000001c9387a8 Oops: Kernel access of bad area, sig: 11 [#1] SMP NR_CPUS=1024 NUMA PowerNV : NIP [d00000001c9387a8] .tg3_io_error_detected+0x78/0x2a0 [tg3] LR [d00000001c9387a4] .tg3_io_error_detected+0x74/0x2a0 [tg3] Call Trace: [c000003f93a0f960] [d00000001c9387a4] .tg3_io_error_detected+0x74/0x2a0 [tg3] [c000003f93a0fa30] [c00000000003844c] .eeh_report_error+0xac/0x120 [c000003f93a0fac0] [c0000000000371bc] .eeh_pe_dev_traverse+0x8c/0x150 [c000003f93a0fb60] [c000000000038858] .eeh_handle_normal_event+0x128/0x3d0 [c000003f93a0fbf0] [c000000000038db8] .eeh_handle_event+0x2b8/0x2c0 [c000003f93a0fc90] [c000000000038e80] .eeh_event_handler+0xc0/0x170 [c000003f93a0fd30] [c0000000000cc000] .kthread+0xf0/0x100 [c000003f93a0fe30] [c00000000000a0dc] .ret_from_kernel_thread+0x5c/0x80
Reported-by: Wei Yang Signed-off-by: Gavin Shan Acked-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Turning off led on port 0 of the 5719 serdes causes all other ports to lose power and stop functioning. Add tg3_phy_led_bug() function to check for this condition. We use a switch() in tg3_phy_led_bug() for consistency with the tg3_phy_power_bug() function.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 6829309926b90c4c32d1f4cafeb600cd34a721e3 Author: Daniel Borkmann Date: Tue Aug 13 11:45:13 2013 -0700
net: tg3: fix NULL pointer dereference in tg3_io_error_detected and tg3_io_slot_reset
Commit d8af4dfd8 ("net/tg3: Fix kernel crash") introduced a possible NULL pointer dereference in tg3 driver when !netdev || !netif_running(netdev) condition is met and netdev is NULL. Then, the jump to the 'done' label calls dev_close() with a netdevice that is NULL. Therefore, only call dev_close() when we have a netdevice, but one that is not running.
[ Add the same checks in tg3_io_slot_reset() per Gavin Shan - by Nithin Nayak Sujir ]
Reported-by: Dave Jones Signed-off-by: Daniel Borkmann Cc: Gavin Shan Cc: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The 5762 devices sometimes incorrectly treat udp fragments as RMCP packets and route to the APE. This patch sets the RX_MODE_IPV4_FRAG_FIX bit for these devices which enables the proper behaviour.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The PTP_CAPABLE tg3 devices have a gpio output that is toggled when the free running counter matches a watchdog value. This patch adds support to set the watchdog and enable this feature.
Since the output is controlled via bits in the EAV_REF_CLCK_CTL register, we have to read-modify-write it when we stop/resume.
Cc: Richard Cochran Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Allow NVRAM programming when interface is down
Previously, when the interface was brought down, the driver would set the power state to D3hot. In D3hot, we don't have access to the NVRAM. This patch removes the call to set the power state to PCI_D3hot in close. A following patch will implement the shutdown handler to properly set the D3hot state when the system is going down.
Doing the above means that the TG3_PHYFLG_IS_LOW_POWER should not be checked to validate access to the NVRAM.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
During probe, the driver is incorrectly switching the power to Vaux on the 5717 and later devices. At this point, we are in D0 state and drawing maximum power. We also definitely have Vmain available. It doesn't make sense to switch to Vaux since it has a lesser maximum power draw and we might go over the limit. On a new system, we observe that not all ports are recognized in some of the slots with this call in place.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
When the EEH error is the result of a fenced host bridge, MMIO accesses can be very slow (milliseconds) to timeout and return all 1's, thus causing the driver various timeout loops to take way too long and trigger soft-lockup warnings (in addition to taking minutes to recover).
It might be worthwhile to check if for any of these cases, ffffffff is a valid possible value, and if not, bail early since that means the HW is either gone or isolated. In the meantime, checking that the PCI channel is offline would be workaround of the problem.
Cc: # v3.0+ Signed-off-by: Gavin Shan Signed-off-by: David S. Miller
commit 72bb72b0d98847d22c6fae4e170121f3640f0f60 Author: Michael Chan Date: Mon Jun 17 13:47:25 2013 -0700
tg3: Prevent system hang during repeated EEH errors.
The current tg3 code assumes the pci_error_handlers to be always called in sequence. In particular, during ->error_detected(), NAPI is disabled and the device is shutdown. The device is later reset and NAPI re-enabled in ->slot_reset() and ->resume().
In EEH, if more than 6 errors are detected in a hour, only ->error_detected() will be called. This will leave the driver in an inconsistent state as NAPI is disabled but netif_running state is still true. When the device is later closed, we'll try to disable NAPI again and it will loop forever.
We fix this by closing the device if we encounter any error conditions during the normal sequence of the pci_error_handlers.
v2: Remove the changes in tg3_io_resume() based on Benjamin Poirier's feedback.
Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
Some systems that don't need wake-on-lan may choose to power down the chip on system standby. Upon resume, the power on causes the boot code to startup and initialize the hardware. On one new platform, this is causing the device to go into a bad state due to a race between the driver and boot code, once every several hundred resumes. The same race exists on open since we come up from a power on.
This patch adds a wait for boot code signature at the beginning of tg3_init_hw() which is common to both cases. If there has not been a power-off or the boot code has already completed, the signature will be present and poll_fw() returns immediately. Also return immediately if the device does not have firmware.
Cc: stable@vger.kernel.org Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
Commit 091f0ea30074bc43f9250961b3247af713024bc6 "tg3: Add New 5719 Read DMA workaround" added a workaround for TX DMA stall on the 5719. This workaround needs to be applied to the 5720 as well.
Cc: stable@vger.kernel.org Reported-by: Roland Dreier Tested-by: Roland Dreier Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The current code calls tg3_set_bdinfo() separately on napi0, followed by a loop that does napi1+. Simplify it by setting bdinfo in the loop for all napi contexts.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Split APE driver state change out of boot reset signature update
Unlike the boot signature that needs to be set before every reset, the ape state only needs to be updated to tell the firmware that the driver is now taking/releasing control of the hardware. Move the calls to tg3_ape_driver_state_change() to better, more appropriate places.
Also, the firmware does not distinguish between SUSPEND and START states anymore. Remove the SUSPEND case in the switch.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: Ensure boot code has completed initialization before accessing hardware
After resetting the device, the driver waits for a signature to be updated to know that firmware has completed initialization. However, the call to tg3_poll_fw() is being done too late and we're writing to the GRC_MODE register before it has completely initialized, causing contention with firmware. This logic has existed since day one but is causing PCIE link to go down randomly at startup on one platform once every few hundred reboots.
Move the tg3_poll_fw() up to before we write to the GRC_MODE register after reset.
Signed-off-by: Nithin Nayak Sujir Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 1cbf9eb85a6601b58f01a71ff10299d2bf5d3365 Author: Nithin Sujir Date: Sat May 18 06:26:55 2013 +0000
tg3: Implement set/get_eee handlers
Reviewed-by: Ben Li Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 5b6c273ad6c3886f30c7c5df7009e489043c59f3 Author: Nithin Sujir Date: Sat May 18 06:26:54 2013 +0000
tg3: Simplify tg3_phy_eee_config_ok() by reusing tg3_eee_pull_config()
eee_config_ok() was checking only for mismatch in advertised settings. This patch expands the scope of eee_config_ok() to check for mismatch in the other eee settings. On mismatch we will require a call to tg3_setup_eee() to push the configured settings to the hardware.
Reviewed-by: Ben Li Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 400dfbaa8d444a29056b051a3d7082dc611e3b12 Author: Nithin Sujir Date: Sat May 18 06:26:53 2013 +0000
tg3: Add tg3_eee_pull_config() function
Add tg3_eee_pull_config() to pull the settings from the hardware and populate the eee structure.
If Link Flap Avoidance is enabled, we pull the eee settings from the hw so as not to cause a phy reset on eee config mismatch later. This requires moving down tg3_setup_eee() below the tg3_pull_config() to not trample existing settings.
Reviewed-by: Ben Li Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
commit 9e2ecbeb250dee67f4bd06a18637c120b48a4865 Author: Nithin Sujir Date: Sat May 18 06:26:52 2013 +0000
tg3: Add ethtool_eee struct and tg3_setup_eee()
Add an eee structure and update it with eee settings. This will be used for set/get_eee operations. Add common function tg3_setup_eee() that will be used in the subsequent patches.
Reviewed-by: Ben Li Signed-off-by: Michael Chan Signed-off-by: Nithin Nayak Sujir Signed-off-by: David S. Miller
The commit f233a976ad15c3b8c54c0157f3c41d23f7514279 (tg3: shows HW time stamping support only if ptp_capable is present) didn't append hardware flags correctly. This patch fixes it.
Signed-off-by: Flavio Leitner Signed-off-by: David S. Miller
net: vlan: add protocol argument to packet tagging functions
Add a protocol argument to the VLAN packet tagging functions. In case of HW tagging, we need that protocol available in the ndo_start_xmit functions, so it is stored in a new field in the skb. The new field fits into a hole (on 64 bit) and doesn't increase the sks's size.
Signed-off-by: Patrick McHardy Signed-off-by: David S. Miller
net: vlan: rename NETIF_F_HW_VLAN_* feature flags to NETIF_F_HW_VLAN_CTAG_*
Rename the hardware VLAN acceleration features to include "CTAG" to indicate that they only support CTAGs. Follow up patches will introduce 802.1ad server provider tagging (STAGs) and require the distinction for hardware not supporting acclerating both.
Signed-off-by: Patrick McHardy Signed-off-by: David S. Miller
tg3: Reset the phy to allow modified EEE settings to take effect
When LFA is enabled, we don't reset the phy. But EEE settings changes don't take effect until the phy is reset. Add a phy reset when we detect a changed EEE setting.