=============================================================================== Mellanox OFED for Windows UpdateXpress Release Notes for IBM Version MLNX_WinOF 4.55 Last Modified on October 13, 2013 ===============================================================================
THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (PRODUCT(S)) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES AS-IS WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Mellanox®, Mellanox logo, BridgeX®, ConnectX®, CORE-Direct®, InfiniBridge®, InfiniHost®, InfiniScale®, MLNX-OS®, PhyX®, SwitchX®, UFM®, Virtual Protocol Interconnect® and Voltaire® are registered trademarks of Mellanox Technologies, Ltd.
Connect-IB™, ExtendX™, FabricIT™, Mellanox Open Ethernet™, Mellanox Virtual Modular Switch™, MetroX™, MetroDX™, ScalableHPC™, Unbreakable-Link™ are trademarks of Mellanox Technologies, Ltd.
All other trademarks are property of their respective owners.
=============================================================================== Table of Contents =============================================================================== 1. Overview 2. Changes in This Release 3. Supported Firmware and Firmware Tools 4. Change Log History 4.1 WinOF VPI v4.55 Main Changes (from v4.3) 4.2 WinOF VPI v4.3 Main Changes (from v4.2) 4.3 WinOF VPI v4.2 Main Changes 5. Known Issues 6. Bug Fixes History 6.1 WinOF VPI v4.55 Bug Fixes 6.2 WinOF VPI v4.40 Bug Fixes 6.3 WinOF VPI v4.2 Bug Fixes 7. API Changes 7.1 WinOF VPI v4.55 API Changes: 7.1 WinOF VPI v4.40 API Changes:
=============================================================================== 1. Overview =============================================================================== This document addresses the Mellanox WinOF VPI driver package distributed for Windows Server 2012 R2 (x64 only). Mellanox WinOF VPI is composed of several software modules that contain an InfiniBand and Ethernet driver. The Mellanox WinOF VPI driver supports Infiniband and 10GB Ethernet ports. The port type is determined upon boot based on card’s capability and user setting.
=============================================================================== 2. Changes in This Release =============================================================================== WinOF VPI v4.55 provides the following changes and new features:
- Generic - Added support for Windows Server 2012 R2 Operating System - Added the ParentBusPath option to each port registry key - Added a new hardware ID for ConnectX®-3 Pro NICs - The QP numbers allocation are now round-robin manner - RecvCompletionMethod as Interrupt is no longer supported - Removed the LsoV1IPv4 from the registry/UI - Removed from the bus driver configuration the ‘Non-DMA’ option - Removed the TXRingNum option from the UI - NVGRE - NVGRE hardware off-load with ConnectX®-3 Pro cards only - Added to the UI the *EncapsulatedPacketTaskOffload option when using ConnectX®-3 Pro NICs - Performance - Added the nd_send_bw and nd_send_lat ND benchmarking tools - Ethernet - Added IP-IP checksum off-load support - Added Ports TX arbitration/Bandwidth allocation per port - The following ND providers, MLX4ND and MLX4ND2 are installed by default - InfiniBand - IPoIB performance improvements - RoCE - Added Sniffer for RoCE packets - The used RoCE mode set upon driver load is printed into event log message =============================================================================== 3. Supported Firmware and Firmware Tools =============================================================================== - Firmware: - ConnectX®-3 Pro QDR/FDR10/FDR and ConnectX®-3 Pro EN - For the firmware version, please contact Mellanox support. - ConnectX®-3 QDR/FDR10/FDR and ConnectX®-3 EN - Firmware v2.11.0500 and above - ConnectX®-2 SDR/DDR/QDR and ConnectX®-2 EN - Firmware v2.9.1200 and above
- Tools: - MFT (Mellanox Firmware Tools) version 2.7.0 and later
=============================================================================== 4. Change Log History =============================================================================== 4.1 WinOF VPI v4.40 Main Changes (from v4.3): ------------------------------------------------------------------------------- - Added a notification in the event log in case SMB is not supported in ConnectX®-2 firmware - Added the trace tool for WPP tracing - Set 512 RX buffers by default - Removed TXRingNum - Changed the perf_tuning setting to achieve a better performance tuning - Added Transmit Side Scaling (TSS) - Added Ethernet QoS proprietary counters, diagnostics and traffic for monitoring, using Windows’ perfmon utility - Enabled MaxRssProcessirs support of the following values: 1, 2, 4, 8, 16, 32,64 - Added to the MTU size the IP header size (1500 ->1514, 9600->9614). Thus the minimum Jumbo frame size is 614. - Interrupt moderation supports the following profiles: - Low Latency - Moderate - Aggressive in addition to old values that are not supported anymore - Made mlx4_bus and Ethernet devices removable - Network Direct: Added support for NDv2 - Network Direct: Set the default ND provide value to mlx4nd2 - Network Direct: Removed the option of NDK registration failure requiring a reboot of the machine to register it again - Network Direct: Added the option of sensing the incoming Read messages according to the device capabilities when creating an EndPoint limit - Removed the QoS attributes when disabling QoS - Added active_mtu field to struct ib_port_attr_t - Added the option of vstat displaying the active_mtu of the ports - Allowed registration of a large Memory Region which is splitted to many segments - Added the option of ibv_devinfo displaying the correct MTU value after it was changed - Added the option of part_man printing the adapter name when the Port GUID is set to zero - Added the option of part_man printing the leading zeroes of port GUID - Prevented displaying a message to upgrade the firmware for OEM NICs if it has the latest firmware version - Removed portsetting registry key during uninstall
4.2 WinOF VPI v4.3 Main Changes (from v4.2): ------------------------------------------------------------------------------- - Added support for a new provider called MLX4ND, which supports both NDv1 and NDv2 interfaces - Enabled performance tuning running according to the operating systems that are running over it - The keywords added to the registry in NDIS support Windows 2012 are: - RssMaxProcNumber - NumRSSQueues - RSSProfile - The keywords added to the registry In NDIS support Windows 2008 R2 are: - RssBaseProcNumber - MaxRssProcessors - RssBaseProcGroup - The rest of the keywords are added in all versions of NDIS. This change is based on: http://msdn.microsoft.com/en-us/library/windows/hardware/ff570864(v=vs.85).aspx - RoCE MTU value is no longer set to 1024 by default - All options stay as they are and can only be chosen if they were selected explicitly in the UI/registry - The current default state is as follows: The value is now derived from the MTU (or MaxFramSize, or Jumbo Packets value) and they are all aliases for the same value). The value is aligned to 256,512,1024,2048 in a way that it will be rounded down to the nearest power of two of the ETH MTU. - Added ibdiagnet utility support
4.3 WinOF VPI v4.2 Main Changes: ------------------------------------------------------------------------------- - Modified RSS cores and changed VMQ affinity on the fly - Added support for K-GROUPS processors (more than 64 processors support) to allow assignment of MSI-X affinity for multiple processor groups. - Set an adequate number of MTTs to map all physical memory - Allocated firmware and ICM memory in chunks of non-paged memory instead of using contiguous physical memory. - Changed device names in device manager and their hardware IDs. The changes were made to distinguish between ConnectX®-2 and ConnectX®-3: - for ConnectX-2: MLX4\ConnectX-2_Eth and IBA\ConnectX-2_IPoIB - for ConnectX-3: MLX4\ConnectX-3_Eth and IBA\ConnectX-3_IPoIB - Set QoS settings only for ConnectX-3. Changing the hardware ID, forces the OS to install new device and re-build the registry keys. - Added an event log to indicate driver failure upon start if there are two HCA burned with the same GUID. - Added firmware upgrade support as part of the setup process. The setup burns the new firmware only on Mellanox cards. Firmware burning failure does not prevent the driver’s installation, therefore, it will show a warning. In this case, it is recommended to update the firmware manually. - Enabled configuration of TxRingNum registry key from the UI - Improved the "Port Protocol" dialog - Added Registry key documentation to the setup package - Optimized code performance - Increased send parallelism - Memory used in receive flow is now allocated with the same affinity of the handling processor for faster access - Statistics parameters are now directly read from hardware instead of being calculated by software - Added support for BlueFlame. BlueFlame is now the default working mode for all packets that have a descriptor which fits into a BF register (currently 256 bytes). - Use "BlueFlame" registry key to enable\disable this feature. - Added support for RSS functionality on available processors numbers. Used to be restricted to start at the first processor. - Changed RSS registry defaults to give better out of the box performance - Added a performance UI to tune performance under various scenarios - Added a tool to tune performance under various scenarios - Added support for multiple TX rings - Added an option to verify that the number of multicast groups used is no higher than the firmware limits - Improved performance in virtualization when using VMQ - Added support for multiple TX rings. The new driver advertises its TSS capability (using multiple TX rings). This feature will not be used when communicating with older version drivers (such as the inbox driver). This way IPv4 communication in a mixed environment that includes the inbox driver should work. IPv6 communication may be problematic in such an environment. - Eliminated some race conditions in IPoIB mcast handling - Added mcast addresses according to the Windows mcast table in addition to mcast addresses from igmp\mld queries, in order to connect to such mcasts that are not reported by the queries. - Removed redundant LID_CHANGE events. This fixes the redundant reconnection of all IPoIB mcasts. - Added support for VM migration. When a VM is migrated from one host to another it does not send a new ARP to hosts it already knew when it was sitting on the first host. In order to prevent communication interruption to such hosts, the driver will initiate an ARP to learn them again. - Removed affinity restriction to group 0 for NDK - Added support for the part_man tool. It can create only one additional IPoIB interface per port GUID. This feature can be utilized to use different IPoIB interfaces for SMB and Hyper-V. The virtual ports configuration is removed during uninstal - Installed ND by default - The following tools were added to the setup package: - ibv_asyncwatch.exe - ibv_atomic_bw.exe - ibv_atomic_lat.exe - ibv_devinfo.exe - ibv_rc_pingpong.exe - ibv_rdma_bw.exe - ibv_rdma_lat.exe - ibaddr.exe - ibcacheedit.exe - iblinkinfo.exe - ibqueryerrors.exe - ibsysstat.exe - saquery.exe - smpdump.exe
=============================================================================== 5. Known Issues =============================================================================== - On rare occasions, depends on the GUID assignment, the IPoIB MAC address can be assigned with a multicast MAC (the least significant bit of the most significant address octet is set to 1).In that case, all of the traffic over the IPoIB I/F are dropped. If you experience this issue, please contact Mellanox support. - OpenSM is currently at beta level. We do not recommend using it in deployment setups. If OpenSM is required in your setup, please use a Mellanox managed switch or UFM. - WinVerbs is no longer supported. We recommend installing MLX4ND. - The following are the unsupported functionality/features in WinOF Rev 4.55: - Connect-X® adapter cards - ND over WinVerbs provider - SRP - ConnectX®-2 Adapter Limitations - Limited NDK support - for details contact Mellanox Support. - CQ to EQ feature is not supported - consequently, the driver may associate RSS and VMQ packets with the wrong CPUs - Mellanox perfmon counters are not supported - Auto-sensing is not supported - ibdump is not supported - QoS is not supported - Pinning all the physical memory (used by RDMA operations, such as register memory, pin user memory) on the machine, on Operating Systems prior to Windows Server 2012, may cause the machine to hang.oS is not supported - The displayed MAC address in the DHCP server of virtual IPoIB I/F may display a wrong data (FF00........) although the I/F is still fully functional. - When running applications that use ND or libibumad (such as OpenSM) the system might get to a unstable state when trying to shutdown/restart/hibernate it. - Activating NC-SI in WinOF v4.55 may cause the driver to fail loading - When trying to use the following WMI classes and operations, an error or empty messages will be displayed: - MLNX_Card - MLNX_FirmwareIdentity - MLNX_FirmwareInstallationServic - MLNX_Realizes - The maximum values returned by the ib_query_ca() function (for example: max_qp, max_mr) are the upper limits of the supported resources by the device. However, it may be impossible to use these maximum values, since the actual number of any resource that can be created may be limited by the machine configuration, the amount of host memory, user permissions, and the amount of resources already in use by other users/processes. - On ConnectX-2/ConnectX-3 Ethernet adapter cards, there is a mismatch between the GUID value returned by firmware management tools and that returned by fabric/driver utilities that read the GUID via device firmware (e.g., using ibstat). Mlxburn/flint return 0xffff as GUID while the utilities return a value derived from the MAC address. For all driver/firmware/software purposes, the latter value should be used. - When uninstalling and reinstalling the driver, the ConnectX-3 Pro Ethernet device will be displayed in the Device Manager with a yellow bang (!). - Active links disappear after changing the cable connectivity from Ethernet to InfiniBand or vise versa. - The installation process does not close any applications running in the background, and may cause a BSOD as a result of a stuck cmd. - InfiniBand application that was compiled with an SDK version earlier than WinOF v4.40 isn't binary compatible - WMI does not work due to lack of permissions - WinOF 4.40 and above IPoIB driver is not IPv6 compatible with earlier driver versions, including Window 8 Inbox driver. If WinOF 4.50 IPoIB node receives an icmpv6 message from the legacy IPoIB node, the following event will appear in the event log: "IPoIB driver detected a possible incompatibility with Windows 8 inbox IPv6 support due to which there is no IPv6 connectivity”. - On rare occasions, as a result of port configuration change (IB/ETH) the UI may get stuck for up to a few minutes. This effect does not require any user action. The UI returns to its proper functionality after a few minutes. - WinOF Inbox driver does not support upgrade. When installing WinOF v4.40 and above on a Windows Server 2012 and above machine, the Inbox driver is uninstalled prior to starting the new installation and any previous configurations is lost. The Inbox driver will be reinstalled automatically when the new driver is uninstalled. - Without separate ports for each stream, WinSock multiplexes every packet to every subscriber socket and then filters it out. - The "Packets Received Discarded" and "Packets Received Errors" counter may display wrong results. - Firmware upgrade may fail during installation if there was a prior firmware upgrade on the machine without a reboot after it. A firmware upgrade failure does not fail the whole installation. - The drivers’ functionality is limited up to 1TB of memory and up to 128 cores. - Connection failure on ND tests while machine A have IBAL provider and machine B have MLX4ND provider - Hibernate and Sleep are not functional when user-space is using its resources. - Calling ib_join_mcast() with timeout_ms = 0 may result in a BSOD. - IPoIB does not support: - MAC address change - QoS (packet priority) - Load balancing and fail-over (LBFO) - Connected Mode - Partition - Memory registration on 32bit machines is limited to up to 256GB. - In an interoperability environment that has both Linux and Windows OSs, the MTU value must be the same, otherwise packets larger than the minimum will not go through. The default MTU for Linux is 2K and for Windows is 4K - Old InfiniBand application must be recompiled with the latest SDK version. - iSCSI boot over IPoIB is currently not functional - OpenSM does not run as a service during installation since the SM requires the GUID parameter to decide which port to work on. Setting it on setup causes it to work only on the first port and not the others. - Tools issues: - ibportstate does not work on RoCE ports - ibdiagpath may crash on Hyper-V machines - If an application which uses InfiniBand runs while the driver is being restarted, a bluescreen or an NMI may occur. - If OpenSM is up during driver restart on the same machine, it might stop working when the driver is being backed up. - When configuring one of the ports to be IPoIB, Mellanox device appears in the Eject Devices. - A virtual IPoIB interface, created by the part_man utility, reports an Active state when the physical link is in the Initializing state and OpenSM is not running in the subnet - Disabling the "Priority & VLAN tag" in the UI which VLANID is configured, may result in sending packets with the configured VLANID. - WakeOnMagicPacket registry key is not added to the registry although WoL is supported by the driver and by the NIC. - When the ports of the device are configured as Ethernet only, ibstat/vstat may display wrong information - The DCB component specifies a default traffic classification that is applied to all egress packets that do not match other classification conditions. In this case, the network adapter assigns the IEEE 802.1p priority level that is associated with the default classification to these egress packets. The default traffic classification has the following attributes: - It has a traffic classification condition of type NDIS_QOS_CONDITION_DEFAULT. - It is the first traffic classification defined in the array of NDIS_QOS_CLASSIFICATION_ELEMENT structures - High multicast drop rate on multicast storming. - When there is a stress in TCP connection establishments, some of those connections may fail - Wake on Lan (WoL) cannot be disabled on NICs which supports it. - When NVGRE offload is enabled the GRE traffic cannot be accepted as a regular L2 traffic and requires special L2_TUNNELING steering rules. In such case the GRE packets are dropped or directed to promiscuous queue. - GRE traffic steering by inner MAC and by outer MAC simultaneously is currently not supported. - If VMQ set filter request are accepted without a GRE flag (i.e. requested steering by outer MAC), the GRE packets do not reach that VMQ. - Running Quality of Service (QoS) commands without the parameter "-PolicyStore ActiveStore” may cause machines to load without Quality of Service policy. - RoCE does not support: - Traffic cannot go through the router. It works in the same subnet only - Multicast traffic - VLAN - Layer 3 feature - Using different versions of RoCE in your cluster is not supported. - When using WinOF 4.40 or above, low throughput will be seen on 40GbE adapters when QoS is enabled - Perf_tuning is supported only when one of the two NUMA nodes are in use. - Execution of nd_write_lat over mlx4ndv1 or mlx4ndv2 may never end. - When the vSwitch is detached from the ETH\IPoIB device while the driver is disabled, the device does not reacquire the static IP it had before the attachment of the vSwitch. When the vSwitch is attached to the ETH\IPoIB device while there is no link, it will not receive the device IP when the link is back up. - After attaching the vSwitch to the ETH\IPoIB device, changing the “Jumbo Packet” registry key on the ETH\IPoIB device does not affect the vSwitch configuration and vice versa. For example, if the user sets the “Jumbo Packet” on the ETH\IPoIB device to X, and the “Jumbo Packet” on the vSwitch to X+Y, X+Y sized packets will be passed from NDIS down to the driver and they will be dropped by it. - Unexpected behavior might occur when running in a virtualized environment and creating two virtual switches bound to each of the ports of a dual port NIC and then using both of them with two vNICs from the same VM. - When moving an IPoIB interface in a VM from non-VMQ to VMQ or from VMQ to non-VMQ, a reset to the NIC may occur and in the event log the following message will appear: ‘device reports a "CQE error" on cqn qpn Status . Therefore, the HCA Nic will be reset. (The issue is reported in Function ). For more information refer to details.’ - In IPoIB when using long Multicast traffic from a Virtual Machine (VM) to an external host there might be up to 0.5% loss in 5% bursts - Hyper-V is at low bandwidth on LBFO vSwitch, Windows 2012 - In Ethernet to achieve better iperf TCP performance between a Linux VM and a Windows VM on different hosts, when using MS MUX over the Ethernet driver, use the non VMQ mode for the VMs. - After disabling and enabling a port on a guest, a ping to it may be renewed after a minute. The ARP requests sent by Windows are less frequent as the time passes. If the guest port was down for a while, it could take time until Windows decides to send another ARP request to it. - When VMQ is enabled after reset, the driver loads all the VMQs that existed before the reset. However, it is not guaranteed that each VMQ will receive the same QP number it had before the reset. This can cause some delay as a result of resetting before connectivity is reestablished. The delay is caused by the time it takes for the ARP table to update after initiating the Gratuitous ARP. - The IPoIB non-VMQ mode is supported only when the VMQ is enabled according to the registry values. - Upgrading the driver while the UI is opened with the "ConnectX NIC device" may cause the installation process to never end. - Rebooting the machine reboot while uninstalling WinOF, may result in installation failure. - Canceling the installation process may leave the bus driver in a disable state. The driver appears in a yellow bang containing the following error message: “Windows cannot start this hardware device because its configuration information (in the registry) is incomplete or damaged. (Code 19)”. - Downgrade is not supported - ibdump may encounter packet drops upon a burst of more than 4096 (or 2^max-burst) packets - Packets loss is not reported by ibdump - Running ibdump on a RoCE Ethernet port may decrease the functional bandwidth due to the overhead of creating extra copy for each packet. This may lead to packet drops on the link. Verify Ethernet flow control is enable to ensure a lossless link - Sniffing over IB ports is currently not supported
=============================================================================== 6. Bug Fixes History =============================================================================== 6.1 WinOF VPI v4.55 Bug Fixes: ------------------------------------------------------------------------------- - Fixed nd_*_bw to achieve better performance (memory buffer alignment) and consistent results - Fixed the issue preventing messages to be sent in VLAN 0 when using many VMQ rings - Fixed a part_man issue related to wrong statistics over virtual partman interfaces
6.2 WinOF VPI v4.40 Bug Fixes: ------------------------------------------------------------------------------- - Fixed an issue causing the setup to fail upon perf_tune failure during the installation. An error message will be printed in the installation log upon perf_tune failure. - Removed port setting registry key during uninstall - Fixed and issue with the Mellanox adapter being shown on the USB removal menu, which caused the removal of the Mellanox adapter once removing the USB. - Fixed the perf_tuning indication of the last chosen tuning scenarios - Fixed a crash in the ib_send_lat/bw utilities caused when the port link was down - Fixed the “Restore to defaults” option in the perf_tuning tool. Now the default values are being restored - Fixed WoL support on NIC with a single port - Fixed the default RoCE configuration on NICs with a single ports - Fixed the values for the MTU and rate of the CM-REQ - Fixed miniport reset on sending scenarios - Network Direct: Fixed a crash occurred when more than 4 SGEs elements were used in an ND write operation - Network Direct: Fixed the swap of InboundReadLimit and OutboundReadLimit when creating an EndPoint and in Connector::GetConnectionData - Network Direct: Fixed disallowing creation of EndPoint with zero attributes in the Receive Queue - Network Direct: Fixed a failure when creating an EndPoint with zero attributes in the Receive Queue - Fixed a bluescreen issue that occurred when disabling the interface after a TX stress over the VMQ - Fixed a failure of MPI/ND over InfiniBand
6.3 WinOF VPI v4.2 Bug Fixes: ------------------------------------------------------------------------------- - Fixed restart issue when there are not enough MSI-X vectors for each machine core - Fixed RSS indirection table mapping building when there are less RX rings than RSS cores - Fixed a bug, preventing standard work with BAR value more than 4GB. - Fixed memory leaks - Fixed error flows causing a Bluescreen in driver startup/unload - Fixed a Bluescreen occurrence upon shutdown due to leak in active resources - Fixed a bug that prevented IBAL applications from working on machines with 2 cards - Fixed a bug that caused packet drop on remote node when the first sent packet is not an ARP or a multicast packet - Fixed IPoIB VMQ affinity update bugs - Fixed IPoIB VMQ parent queue management race during reset - Fixed a bug in passing DHCP packets from a Linux VM - Fixed bug in RDMA statistics for NDK
=============================================================================== 7. API Changes ===============================================================================
7.1 WinOF VPI v4.55 API Changes: ------------------------------------------------------------------------------- - RDMA_TRANSPORT_RRDMAOE_1_5 - Enumerated values were added - RDMA_TRANSPORT_RRDMAOE_2_0 - Enumerated values were added - RDMA_TRANSPORT_RRDMAOE It is an alias to RDMA_TRANSPORT_RRDMAOE_1_5 - is_rroce(), is_xroce() - Added new functions - IB_AC_SNIFFER - Added a new macro - struct ib_qp_mod_t - The field state.init.flags was added
7.2 WinOF VPI v4.40 API Changes: ------------------------------------------------------------------------------- - VERBS_MINOR_VER - Increased its value, 0009 -> 000a - enum eth_link_speeds - Enumerated values were added - struct ib_port_attr_t: - The mtu field was separated into two fields: - max_mtu (maximum MTU supported by the port) - active_mtu (actual MTU which the port is configured with) - Added the eth_link_speed field - WR_SEND_INV - Enumerated value was added - struct ib_send_wr_t - The type of invalidate_rkey was changed from net32_t -> ib_net32_t - IB_SEND_OPT_SKIP_DOORBELL - Added the send Write flag mlnx_fw_nic_4_55_9096p4_win2k12r2_32-64_chg
=============================================================================== Emulex FCoE Device Driver for Windows ===============================================================================
Driver version: 2.74.016.001 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - Cleaned up a variety of corner case issues to avoid BSODs - Fixed IOCTL encounter bug-chk on BE3 during NPIV tests - Fixed reporting incorrect error code when creating vport on a switch without NPIV supported - Updated the default model name for 10Gb CNAs and 16G HBAs
Driver version: 2.74.009.001 (Previously supported on IBM SystemX, BladeCenter & Flex)
Problems Fixed: - Clean up non-critical legacy FC and uCNA incompatibilities - LUN masking doesn't persist after reboot - Emulex GUI crashes when closing a running Upgrade utility and re-open it in 802.3 configuration with IP or MAC - Several bugs related to creation or deletion of vports
Incremental Interoperability: - Windows 2012 - Improved debug capabilities - Tighter integration with MS Windows Design Kit
Driver version 2.70.018 (Previously supported on IBM SystemX, BladeCenter & Flex)
Problems Fixed:
- Fixed sending ABTS continuously to Flogi issue - Fixed reset and link bounce issues for SLI4 FC public loop - Added support for ABTS timeout handling for both SLI3 and SLI4 - Fixed loopback test incorrectly dropping the loopback frame in SLI4 - Fixed exchange management issue in SLI4 CT receive path causing array overflow - Fixed firmware version update issue following download in link up state - Fixed problem in init_vfi completion handler that stalled fabric login on BE FCoE FW - Fixed problem that caused OCM ELS Echo Test to fail - Fixed the loopback test issue in recovering from error condition - Add persistent link down support for SLI4 FC - Fix DFC_IssueDumpMBox to manage request type 3 which includes link select option - Modified reinitialization sequence following reset to fix discovery failure post type 1 or type 3 reset - Fixed new firmware dump issue
This v18.5 sw release replaces all previous sw releases for IBM eServer System x Intel-based Gigabit and 10 Gigabit Ethernet Adapters.
The key updates with this v18.5 software release include: =========================================================
- Support for Microsoft Windows Server 2012 R2 - Support for the Intel(R) Ethernet OCP Server Adapter X520-2 - Support for the Intel(R) Ethernet OCP Server Adapter X520-1 - Removed driver and software support for Microsoft Windows Server 2008 R1 - Removed Microsoft Windows driver and software support for Itanium-based systems
intc_dd_nic_18_5_windows_32-64_chg
Qlogci iSCSI Adapter STOR Miniport Driver for Windows Release Notes October 09, 2013
This software license applies only to QLogic customers. QLogic Corporation. All rights reserved.
Table of Contents
1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. History 6. Additional Information 7. Embedded Firmware Details 8. Trademarks 9. Notices 10. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and release details that apply to iSCSI driver, version 2.1.5.38.
NOTE: Before installing this driver, you must update the Microsoft STOR miniport driver.
The FC is supported with Microsoft Windows Server 2008, Windows 2008 R2, Windows 2012 and Windows 2012 R2.
2. Changes
N/A
3. Bug Fixes
N/A
4. Known Issues
N/A
5. History
N/A
6. Additional Information
None
7. Embedded Firmware Details
This section provides information for the firmware embedded in the driver:
* Not available
8. Trademarks
QLogic, the QLogic logo, QLA, SANbox, SANsurfer, and SANblade are registered trademarks of QLogic Corporation.
SANtrack and SAN Express are trademarks of QLogic Corporation.
All other brand and product names are trademarks or registered trademarks of their respective owners.
9. Notices
Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
10. Contacting Support
Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods:
North America Contact Information
Email: support@qlogic.com
Phone: (952) 932-4040
Web: http://support.qlogic.com
Support contact information for other regions of the world is available at the QLogic website: http://support.qlogic.com
(c) Copyright 2009. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. qlgc_dd_iscsi_2_1_5_38_windows_32-64_chg
Fibre Channel Adapter STOR Miniport Driver for Windows Release Notes October 09, 2013
QLogic Driver Release Notes
QLogic Corporation All rights reserved
Version 9.1.11.24
Table of Contents
1. Change History 2. Known Issues 3. Notices 4. Contacting Support
1. Change History
The following changes have been made to the Fibre Channel Adapter STOR miniport driver for version 9.1.11.24.
* Firmware version: 5.09.00 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters) * API version 1.28.0.105 (QLSDM) * Fix MailboxPassthru by removing restriction on writing mbx8 register [ER104361] * Added support for Skip 4G FC [ER104575] * Allow application modify "Execution Throttle" field in nvram for 2600 series adapters [ER103297] * Add Service Pack number to OSName [ER104204] * Added api to read 2600 series adapters ASIC temperature [ER102430] * Added mailbox passthru api [ER102988] * Added reading ASIC temperature for Ninja and Sensei [ER103001] * Removed Advanced tab from Device Manager properties * Added support support for full 64 bit physical addressing [ER101742] * Added support for QLE10000 series adapters
Version 9.1.10.28
* Firmware version: 5.07.02 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters) * API version 1.28.0.101 (QLSDM) * Removed support for 2Gb speed in port supported speed for 16Gb FC in 2600 series adapters [ER100053] * Added get/set I2V registers and get/set serdes registers - OEM Adapter [ER99727] * Added support to address OEM adapter Re-design I2C access issue [ER99562] * Added adapter disable state check on timer routine re-init state handling [ER96662] * External loopback support OEM adapter when in loop mode [ER98834] * Fixed skipping OEM adapter vpd update [ER100458] * Fixed Ext Loopback test fails with Loopback connector (8Gb loop mode) [ER99702] * Fixed crash in fwdump routine [ER101039] * Limit support to node-interleaving configurations
Version 9.1.10.27
* Fixed event Viewer Error 154 (Disk I/O error) occurs when running Diskercise on FC LUN [ER97809]
Version 9.1.10.26 * API version 1.28.0.97 (QLSDM) * Added series adapters temperature handling [ER94159] * Removed driver family version support [ER95755] * Removed flash FLT error logging for 24xx/25xx [ER96144] * Returned NOT_SUPPORTED for SDForceFcMctpDump in api [ER96352] * Fixed memory access error [part of ER96188] * Fixed extra 4K in variable transfer sizes (64K, 128K) [ER94081] * Added support to relogin if the device logs out [ER93867] * Removed event logging for fw dump event [ER98897]
Version 9.1.10.25
* Added Windows Server 2012 support [ER92249] * Not to update i2c vpd if Sensei in api [ER93800] * Fixed Flash Layout Table memory usage [ER93668] * API version 1.28.0.96 (QLSDM) * Code cleanup [ER92250] * Added support for Set Driver version for OCBB and family driver version [ER92243] * Issue with LB connector attached after it was in point-to-point mode, driver was still issuing echo instead of loopback command [ER93050] * Fixed Adapter Port type in P2P mode [ER92357] * Process completed PRLI [ER89053] * Fixed multiple request single response queue initialization issue [ER95259]
Version 9.1.9.48
* Firmware version: 5.06.05 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters)
Version 9.1.9.47
* Firmware version: 5.06.04 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters)
Version 9.1.9.46
* Firmware version: 5.06.03 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters) * API version 1.28.0.92 (QLSDM) * LUN disappearance after tape reboot [ER84117] * Failed to reissue some i/o's after controller failover (8Gb) [ER86660]
Version 9.1.9.29
* Firmware version: 5.06.02 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters)
Version 9.1.9.28
* Firmware version: 5.05.05 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters) * API version 1.28.0.87 (QLSDM)
Version 9.1.9.27
* Updated firmware version: 5.04.04 (2400/2500 Series 4Gb and 8Gb Fibre Channel Adapters) * API version 1.28.0.85 (QLSDM) * Fixed an issue where drives were not detected in direct connect topology [ER81138]
Version 9.1.9.25
* No fixes in this driver release.
Version 9.1.8.25
* Closed WMI mapping interoperability with HBAAPI.DLL issue.
Version 9.1.8.19
* Driver restores 4G Fibre Channel PCIe Device Control and Link Control registers based on saved value. * In multi-processor systems, the clustering driver timer popped as a result of unrecovered I/O through a LUN reset. [ER0000000067688 closed]
Version 9.1.8.17
* Firmware versions: 5.01.02 (4Gb and 8Gb) * API version 1.28.0.73 (QLSDM) * Driver restores 4G Fibre Channel PCIe Device Control and Link Control registers based on saved value.
Version 9.1.7.18
* Firmware versions: 3.03.25 (2Gb), 4.04.00 (4Gb and 8Gb). * API version 1.28.0.63 (QLSDM).
Version 9.1.7.17
* Added support for the following devices (supported platforms) (2.3m): - PCI\VEN_1077&DEV_8432&SUBSYS_010E1077 (x86, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_014B1077 (x86, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01701077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01711077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01721077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01731077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01741077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01751077 (x86, ia64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_004A1137 (x86, ia64, x64) * Removed support for the following devices (supported platforms): - PCI\VEN_1077&DEV_2432&SUBSYS_011C1077 (x86, x64) NOTE: Microsoft requires x86 and x64 support for all Fibre Channel Adapters. * Firmware versions: 3.03.25 (2Gb), 4.03.02 (4Gb). * API version 1.28.0.63 (QLSDM). * Added support for 64-bit QLSDM DLLs. * Enabled FDMI by default. * Added support for Atmel flash AT26DF081A. * Removed support for obsolete qd parameter. * Changed the driver to not log events caused by I/O completion errors.
Version 9.1.7.16 QL
* Added support for the Windows Server 2008 operating system. * Applied a fix to handle logout in the loop environment.
Version 9.1.7.15 QL
* Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_2432&SUBSYS_01081077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_015C1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_015D1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_015E1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_015F1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01601077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01611077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01621077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01631077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_01641077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_3261103C (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_3262103C (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_3263103C (x86, IA64, x64) - PCI\VEN_1077&DEV_2532&SUBSYS_3264103C (x86, IA64, x64) NOTE: Microsoft requires x86 and x64 support for all Fibre Channel Adapters. * Firmware versions: 3.03.25 (2Gb), 4.02.00 (4Gb). * API version: 1.28.0.50 (QLSDM). * Unique assignment of management server N_Port handle values to be for each virtual port. * NPIV (N_Port ID virtualization). * Target link speed (iiDMA). * PcieLinkCap/Stat to HbaDeviceChipProperty. * Flash layout regions for 4Gb and returned flash layout table from flash if it is valid. * Three Alternate Boot Devices and OOFR (out-of-order frame receive). * Removed QL2XHAI2: IHVs are required to use Host Bus Adapter API provided by Microsoft. * Preserved BIOS defaults when updating multi-boot image whose BIOS locations can be anywhere in the image. * Fixed checksum calculation in QLSDM when two-bios image is flashed. * Initiator discovery problem caused a large burst of RSCN activity when the NetApp does its failover. A failed GPNID command occurring during ports discovery must not cause the termination of the discovery process. [ER50975 fixed] * Handled the case where the GNNFT command was failing due to incorrectly calculated the maximum data response length. * Setting the alternate WWN and enabling it in the NVRAM did not propagate through to the Host Bus Adapter. Reading the NVRAM and reinitializing the Host Bus Adapter will handle this case.
Version 9.1.4.16 QL 3.03.21 4.00.26
* Adhered to Subsystem Id document v2.2m+. * Firmware versions: 3.03.21 (2Gb), 4.00.26 (4Gb). * API versions: 1.28.0.37 (QLSDM), 2.0.0.14 (QL2XHAI2). * Initiator discovery problem caused a large burst of RSCN activity when the NetApp does its failover. A failed GPNID command occurring during ports discovery must not cause the termination of the discovery process. [ER50975]
Version 9.1.4.15 QL 3.03.21 4.00.26
* Firmware versions: 3.03.21 (2Gb), 4.00.26 (4Gb). * API versions: 1.28.0.37 (QLSDM), 2.0.0.14 (QL2XHAI2). * Adhered to Subsystem Id document v2.2m+. NOTE: Microsoft requires both x86 and x64 support all Host Bus Adapters. * Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_2322&SUBSYS_01151077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2322&SUBSYS_01161077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2422&SUBSYS_1336103C (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_015B1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_5432&SUBSYS_01551077 (x86, x64) - PCI\VEN_1077&DEV_5432&SUBSYS_01561077 (x86, x64) - PCI\VEN_1077&DEV_2422&SUBSYS_014A1077 (IA64) - PCI\VEN_1077&DEV_2432&SUBSYS_014B1077 (IA64) * Removed support for the following devices: - PCI\VEN_1077&DEV_6312&SUBSYS_01301077 (x86, x64) - PCI\VEN_1077&DEV_2422&SUBSYS_01471077 (IA64) - PCI\VEN_1077&DEV_2432&SUBSYS_01451077 (IA64) * Conformed QLSDM and the driver to the revised for "Get/Set Target Link Speed". * Increased loopback test buffer size to 2048 bytes in QLSDM. * Loopback test always failed when the NVRAM frame size is set to 512 or 1024 (Windows). Pass in transfer size instead of hard-coded value in QLSDM. [ER50975 fixed] * Handled the case where the device becomes not ready in the StartIO routine. * Fixed in SANsurfer 5.0.0 Build 4 – Driver 9.1.3.10b2—Windows IA64 SP1—HP. The Host Bus Adapter model numbers do not show up on Information page. [ER48374] * Fixed Long Erase (0x019) issues with DLT S4 and QLE2462. Error occurs (most likely a bus reset) when running a long erase that takes longer than 110 minutes on the Quantum DLT-S4 (firmware:0808) drive, which exceeds the built in 4Gb firmware timeout limit. [ER48117 (AR 48907, SR70415 [REF:609618455])]
Version 9.1.3.16 QL 3.03.21 4.00.23
* This version replaced the invalid release 9.1.3.15. * Firmware versions: 3.03.21 (2Gb), 4.00.23 (4Gb). * API versions: 1.28.0.35 (QLSDM), 2.0.0.14 (QL2XHAI2). * Removed I/O Reduction support for the 4G Host Bus Adapter.
Version 9.1.3.15 QL 3.03.21 4.00.23
* Firmware versions: 3.03.21 (2Gb), 4.00.23 (4Gb). * API versions: 1.28.0.35 (QLSDM), 2.0.0.14 (QL2XHAI2). * Added OEM specific support for assigning a virtual world wide port name via registry key. * Added "Get/Set" target link speed support. * Changed the INF to enable the I/O Reduction for the 4Gb Host Bus Adapter for the IA64 platform based on Microsoft document. * Added multiple BIOS support in QLSDM. * Initialized debug file name variable during DLL load (QL2XHAI2). * Closed EMC OPT23605: x64 Server hangs during boot at the “Applying Computer Settings.” * Cleaned up code related to get Object text for OS Device Name (QL2XHAI2). * Attached target devices not visible to OS after server reboot (QLE220) [ER47338 closed]. * Driver not Login into Target Devices (QLE220) [ER47436 closed] * Topology diagram is not displaying properly when LIP issued on QLA2462 port. [ER47530 closed]
Version 9.1.2.19 QL 3.03.19 4.00.23
* Firmware versions: 3.03.19 (2Gb), 4.00.23 (4Gb). * Bus Resets Under Heavy I/O Load. [ER46891 closed] * API Versions: 1.28.0.33 (QLSDM), 2.0.0.12 (QL2XHAI2). * SANsurfer FC HBA Manager B83 showed only one port see the storage even though no zoning. [ER47166 closed] * Port failure after disconnecting and reconnecting ISL port used by MirrorView. [Closed OPT 235681] * SANsurfer FC HBA Manager does not display the topology view correctly when the Host Bus Adapters are set to loop only until the system is rebooted. [ER47235 closed]
Version 9.1.2.18 QL 3.03.19 4.00.22
* Firmware versions: 3.03.19 (2Gb), 4.00.22 (4Gb). * API Versions: 1.28.0.33 (QLSDM), 2.0.0.12 (QL2XHAI2). * Added VPD update support for 2432 4-port adapter in 1.28.0.33 (QLSDM). * Recognized Asynchronous Event 8048h as a valid AEN. * Modified timer task to handle the case when Host Bus Adapter is in a stopped state. * 24xx only: Added support for NVRAM Nodename option bit. * 4Gb only: Added support for reading data from SFP (small form-factor pluggable) optical transceivers via QLSDM. * Adhered to Subsystem Id document v2.2g. * Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_2422&SUBSYS_014D1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_014C1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_01521077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_01531077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_01541077 (x86, IA64, x64) - PCI\VEN_1077&DEV_5432&SUBSYS_014E1077 (x86, x64) * Adhered to firmware dump procedure per 2400 Series Firmware Interface Specification version C. * RX2600 fails to boot Windows after 1MB bin flash—SANsurfer 2.0.30b84_windows. [ER47113 closed] * Fixed: LUNs disappeared after DS4000 controller firmware download in direct attach. * "Bind By Port ID + Present Targets that are persistently bound only" is not working (in loop environment). [ER46586 closed] * Changed to perform the full firmware dump when firmware error occurs. * JBOD disks turn offline in SANsurfer FC HBA Manager and SANsurfer FC HBA CLI when settings are Present targets that are persistently bound + Bind by Port ID (in loop environment). [ER46141 closed] * Corrected firmware region size in option ROM layout, that is, firmware size in flash. * GPN_ID has wrong payload length after unplug and re-plug. [ER45035 closed] * When using the QLSDM to retrieve the transceiver data, you may get SDMGT_CANNOT_GET_SFP_DATA error on system platforms using specific models of Supermicro motherboard such as P3TDL3 and P3TDLE. The QLSDM retrieves the transceiver data using underlying 4Gb firmware (v4.00.21) that reports an error code of 4005 for this operation. * Verified support for Atmel flash chip AT26DF081A.
Version 9.1.2.16 QL 3.03.19 4.00.18
* Firmware versions: 3.03.19 (2Gb), 4.00.18 (4Gb). * Adhered to Subsystem Id document v2.2f. * Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_6312&SUBSYS_01191077 (x86, x64) - PCI\VEN_1077&DEV_6312&SUBSYS_011C1077 (x86, x64) - PCI\VEN_1077&DEV_6312&SUBSYS_01301077 (x86, x64) - PCI\VEN_1077&DEV_6322&SUBSYS_012F1077 (x86, x64) * Set additional firmware option bit 10 for 2Gb Host Bus Adapter so the firmware waits for the task management command, (such as reset LUN to complete.) * Host Bus Adapter does not re-login to target after target sends LOGO to Host Bus Adapter. [Closed OPT226506] * The link status behaves differently between QLE2460 and QLA2342. [ER44735 closed] * Incorrect HwVersion string is reported by QLogic IHV HBA_GetAdapterAttributes call. [ER45228 closed] * Event Id 11 entries logged by ql2300 at offset x10 and offset x34 do not match the Error Codes published on the Web. Because the miniport uses Microsoft's Storport.sys driver to actually log the error event, and it has been confirmed that the storport.sys driver logs the event incorrectly. A bug has been reported to Microsoft on this: SRX041110604850 (STORport—Incorrect event data is logged when storport's storportlogerror). Meanwhile, the Miniport driver is changed to log the event code at offset x10 by default. This workaround is controlled by the registry parameter mevtwrkaround. For details on this parameter, please see the readme file. [ER45230 closed] * Use memory map mechanism in the driver. [ER45232 closed]
Version 9.1.2.15 QL 3.03.19 4.00.17
* Firmware versions: 3.03.19 (2Gb), 4.00.17 (4Gb). * Adhered to Subsystem Id document v2.2e. * Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_5432&SUBSYS_013E1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_5432&SUBSYS_013F1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2422&SUBSYS_014A1077 (x86, IA64, x64) - PCI\VEN_1077&DEV_2432&SUBSYS_014B1077 (x86, IA64, x64) * Added support to use combined 2Gb IPX firmware. * Added support for SST25VF080B flash part. * Added option for not to dump code section for 24xx firmware dump. * Serial number for the 4Gb Host Bus Adapter should be obtained from the VPD. [ER44270 closed] * Windows 2000/qla2340/Veritas tape backup long cable pull failed error message ERROR_DEVICE_NOT_CONNECTED. [ER38787 closed]
Version 9.1.1.15 QL 3.03.18 4.00.12
* Firmware versions: 3.03.18 (2Gb), 4.00.12 (4Gb). * QLogic 4Gb driver returns selection timeout immediately after cable pull in an OEM special dual loop configuration. [Closed PTR 90818] * QLogic Driver returns a selection timeout when rebooting a controller in an OEM special dual loop configuration. [Closed PTR 90652]
Version 9.1.0.18 QL 3.03.18 4.00.12
* Firmware versions: 3.03.18 (2Gb), 4.00.12 (4Gb). * Adhered to Subsystem Id document v2.2d. * Added support for the following devices (supported platforms): - PCI\VEN_1077&DEV_2422&SUBSYS_12D7103C (x86, IA64, x64) - PCI\VEN_1077&DEV_2312&SUBSYS_01491077 (x86, IA64, x64)
* Firmware versions: 3.03.16 (2Gb), 4.00.12 (4Gb). * Embedded 24xx firmware in the driver. * New driver could not detect any device to install as BOOT from SAN on one specific setup. [ER43175 closed]
Version 9.1.0.15 QL 3.03.16
* Firmware versions: 3.03.16 (2Gb), (Use onboard 4Gb firmware.) * Added 24xx support. * Need to change bit used to control LED mode. [ER42601 closed]
Version 9.0.2.17 QL 3.03.13
* Firmware versions: 3.03.16 (2Gb).
Firmware (Embedded in Driver) -----------------------------
The following lists show the changes and bug fixes to the firmware that is embedded in the drivers for the 4Gb Fibre Channel Adapters and 8Gb Fibre Channel Adapters from versions 4.03.01 to 5.04.04.
From Version 5.04.02 to 5.04.04
Changes ------- * 2500 Series. Ensured that correct slot-specific SerDes settings will be used for specific mezzanine cards. [ER78047]
Bug Fixes --------- None
From Version 5.04.01 to 5.04.02
Changes ------- * Current Fibre Channel Adapter firmware supports maximum frame sizes of 512, 1024, and 2048 in the received PLOGI or PLOGI-ACC. This change provides an option to disable this restriction by setting bit 6 of Firmware Options 2 through Set Additional Firmware Options Mailbox Command (038h). Note that this option bypasses the Maximum Transmit Data Frame Size set by the Set Transmit Parameters Mailbox Command (019h). [ER76448]
Bug Fixes --------- None
From Version 5.04.00 to 5.04.01
Changes ------- * Option to Disable Automatic FDISC: Currently, the firmware automatically performs FDISC for enabled virtual ports (VPs) upon receiving an FLOGI_ACC. This procedure does not mesh well with driver architectures, which typically control the FDISCs. A new option bit allows you to suppress the automatic FDISCs. This option bit is available in both the ISP25xx and ISP81xx firmware. Older firmware ignores this option bit. Functional Description: The Disable FDISC bit (multi-ID initialize firmware control block, Global VP Options field, bit 4) disables the automatic FDISCs. If this bit is set, any VPs enabled in the multi-ID initialize firmware control block remain enabled, but the ID is not in the acquired state. The driver must issue a Modify Virtual Port Configuration IOCB (with the Command field set to 3h) to instruct the firmware to transmit the FDISC after it receives the report ID acquisition (RIDA) for VP0. When Disable FDISC is set, no FDISC is transmitted for the enabled VPs on any event, which results in a FLOGI. The driver should issue a Modify Virtual Port Configuration IOCB (with the Command field set to 3h) to instruct the firmware to transmit the FDISC for a specific VP (after receiving the RIDA for VP0). The driver must instruct the firmware to transmit an FDISC for all enabled VPs. After all the FDISC is completed, the firmware state changes to ready. In addition, a Port Database Changed AEN (8014h), with the Outgoing Mailbox 1 register set to FFFFh and Outgoing Mailbox 2 register set to 6h, is generated and passed to the driver. If the driver does not transmit FDISC for a VP, the driver must disable that specific VP using Virtual Port Control IOCB (Entry Type field 30h). This step is needed because a VP is enabled, but the ID is not in the acquired state, which can prevent the firmware state from changing to ready, and prevent generation of the Port Database AEN as previously stated. The option applies only to fabric point-to-point topology and NPIV environments. [ER74448]
* Added option to disable PRLI REC_SUPPORT bit. To disable the PRLI REC_SUPPORT bit (PRLI REC_SUPPORT bit is set by default), set bit 6 of the additional firmware option 3 of the Set Additional Firmware Options (38h) Mailbox Commands). This option has to be set prior to Initialize Firmware mailbox command (60h or 48h). [ER74764]
* 81xx only. Added Additional Firmware Options 2, bit 9 to improve NIC bandwidth when NIC and FCoE receive traffic are running concurrently. [ER69565]
* 81xx/25xx MIDQ only. Provide capability in Queue Management (1Fh) mailbox command to move a queue base address. For details, refer to the Multiple Queue Support for 2500 Series Fibre Channel and 8100 Series Converged Network Adapter Controllers Applications Note. [ER69606]
* 81xx only. Added support for LR Optics. Requires MPI FW 1.39.00 or later with proper configuration files. [ER69613]
* Added an Additional Firmware Options 3 bit to discard any frames received out of order unless the Initialize Firmware Options 3 bit 6 (Enable Receive Out-of-Order Data Frame Handling) is set to 1. Changes to Set Additional Firmware Options (38h) Mailbox Command interface: - Add to Additional Firmware Option 3 Bits (Incoming mailbox 3 register) Table: Bit 15 Do not transfer received out of order data for an exchange to host memory (except during SRR recovery). - Replace bit_15 description with: Bit 15 (Do not transfer received out of order data for an exchange to host memory). When this bit is set to 1, the ISP firmware does not transfer received out-of-order data for an exchange to host memory, except during SRR recovery. A frame is considered "out-of-order" after a previously-received frame is dropped due to an error, as well as a true out-of-order frame receipt condition. NOTE: Bit 15 is ignored when Initialize Firmware Options 3 bit 6 (Enable Receive Out-of-Order Data Frame Handling) is set to 1. [ER70311]
* 24xx/25xx only. Bit 8 of State Flags field in Status IOCB Type has been changed from Reserved to "Unable to send OPN to Destination." This bit is set when the destination device sends an immediate CLS in response to an OPN from ISP. [ER71132]
* Add option to disable the firmware automatic port login (PLOGI) to the simple name server (SNS). To enable this feature, set Bit 15 of Additional Firmware Options 2 when issuing Set Additional Firmware Options Mailbox Command 0038h. [ER71742]
* 24xx SB2 only. Return the lower 16-bit of current RBC count in Receive IU and Add Buffer IOCBs. This extends the scope of ER68875 to include 24xx. - For IOCB type 0x4D, the lower 16-bit of the counter is stored at offset 0x3E to 0x3F. - For IOCB type 0x4C, the lower 16-bit is stored at offset 0x1C to 0x1D. [ER71764]
* 81xx only. Added an Additional Firmware Options 2 bit to post all Asynchronous IOCBs to the ATIO queue when target mode is enabled. Changes to Set Additional Firmware Options (38h) mailbox command interface: - Add to Additional Firmware Option 2 Bits (Incoming mailbox 2 register) Table: Bit 11 Enable Asynchronous IOCBs to ATIO queue. - Replace bit 11 description with: Bit 11 (Enable Asynchronous IOCBs to ATIO queue). When this bit is set to 1, the firmware posts all asynchronous IOCBs (PUREX, ABTS Received, and Report ID Acquisition) to the ATIO queue when target operation is enabled. Additionally, if a login-affecting ELS command (PLOGI, PRLI, PRLO, LOGO, ADISC, PDISC, or TPRLO) is passed up to the target driver, an Immediate Notify IOCB with Status Code 46h, Login affecting ELS command received, shall not be sent. Initialize Firmware Options 3 bit 26 (Enable Ethernet Header Receive IOCB for ATIO Queue) is used to request the firmware place an Ethernet Header Receive IOCB on the ATIO queue before each PUREX and ABTS Received IOCB. Initialize Firmware Options 3 bit 27 (Enable Ethernet Header Receive IOCB for Response Queue) shall be ignored. When bit 11 is set to 0, the firmware posts asynchronous IOCBs to queues specified in the ISP81xx firmware specification. Changes to Initialize Firmware, Firmware Options 3: - Bit 27 (Enable Ethernet Header Receive IOCB for Response Queue). When Additional Firmware Option 2 bit 11 (Enable Asynchronous IOCBs to ATIO queue) is set, this bit is ignored. - Bit 26 (Enable Ethernet Header Receive IOCB for ATIO Queue). When Additional Firmware Option 2 bit 11 (Enable Asynchronous IOCBs to ATIO queue) is set, and this bit is set, the firmware places an Ethernet Header Receive IOCB on the ATIO queue before each PUREX and ABTS Received IOCB. [ER71877]
* MID only. Send LOGO if an FDISC is rejected with error/explanation code 03/0D. After LOGO ACC is received, the firmware retries the FDISC. [ER72460]
Bug Fixes --------- * 81xx only. Corrected FCP-2 processing during a link disruption until re-discovery is complete. [ER66337]
* MIDQ builds. Corrected N_Port-N_Port FLOGI Dest ID of 0. [ER67952]
* 2532-based adapter only. Corrected an issue that could prevent the link from being established when connected to specific targets operating at 8Gb link speed in a loop topology. [ER68658]
* Correct abort handling of a Command Type 6 IO that could result in fatal firmware error or I/O timeout. [ER68965]
* 81xx only. Set a Buffer Credit value of 16 in FLOGI/FDISC for interoperability with FCFs that incorrectly use the field. [ER69182]
* 81xx only. Correct handling of received stale frames forwarded by an FCF after the link is re-established. [ER69245]
* 81xx only. Corrected an issue that would prevent the link from being re-established after a cable pull. [ER69291]
* Correctly set the "sequence initiative transferred bit" (F_CTL) for transmission of status mode 2 FCP_RSP with confirmation request. [ER69336]
* 81xx only. Added support to detect MPI pause during heartbeat processing. [ER69457]
* Disk CRC only. Correct firmware reported residual Byte Count for CRC (T10) Read commands. [ER69564]
* 81xx only. Corrected CTIO handling when the link was down. [ER69683]
* 81xx only. Corrected an issue with Internal Loopback failure reported when link is up to an FCF. [ER69685]
* 24xx CRC only. Resolve 8002 system error during DIF error processing. [ER69922]
* 25xx and 81xx only. Corrected possible memory leak during clean-up of T10 CRC IOs with DIF Bundling enabled. [ER70018]
* 25xx and 81xx only. Corrected false DIF error reported during T10 CRC transmit IO with DIF Bundling. [ER70038]
* Corrected Target XCB count returned by Get Resource Counts Mailbox Command (0042h). [ER70149]
* Corrected a RISC pause condition after the Diagnostic Echo Test (44h) mailbox command completed with an error status. [ER70166]
* 25xx and 81xx only. Corrected a potential I/O timeout of T10 CRC IO when using DIF bundling. [ER70319]
* 25xx and 81xx only. Corrected potential invalid PCIe access when aborting a T10 CRC IO when using DIF bundling. [ER70558]
* Corrected N_Port Handle assignment by firmware when Purex is enabled. [ER70575]
* 81xx only. The firmware could incorrectly set bit 15 of N_Port Handle returned by the Get Port/Node Name List (75h) mailbox command. [ER70664]
* 81xx only. Corrected a problem where the values supplied in the Set Timeout Parameters (32h) mailbox command were not honored. [ER70708]
* Prevent 8002 system error when processing a severely malformed IOCB. [ER70910]
* Corrected a RISC pause condition during SRR received notify ACK processing. [ER70921]
* 24xx only: Improved link init time when using Inline Credit Extender in an N_Port-N_Port configuration. [ER71034]
* Fixed Loopback mailbox command timeout when Fibre Channel event (FCE) extended tracing is enabled. [ER71269]
* Corrected a problem that could result in a Task Management command timeout. [ER72100]
* Corrected handling of frames received with DID = 000000h. [ER72270]
* 81xx only. Fix CTIO with terminate exchange bit returned good completion status (01h) after the CTIO is already completed. The CTIO with a terminate exchange bit should instead return an invalid receive exchange address (08h) completion status. [ER72491]
* MID builds only. Fix CTIO with terminate exchange bit failed with completion status=29h. [ER72571]
* 81xx only. Corrected a problem that caused FDISC not generated by the firmware when Virtual Port Control IOCB (type=30h) is used to enable VP. [ER72921]
* MID only. Correct the cleanup of outstanding ELS requests during VP disable. [ER73048]
* MID only. Resolve RISC pause after cable pull or link event. [ER73090]
From Version 5.02.00 to 5.03.00
Changes ------- * Added feature to return LOGIN info via Mailbox Command 5Ah - Get Params, using type 7. Entry Parameters (Incoming): Mailbox0 - opcode (005ah) Mailbox1 - Type<15:8>, reserved<7:0> Mailbox2 - buffer addr<31:16> Mailbox3 - buffer addr<15:0> Mailbox6 - buffer addr<63:48> Mailbox7 - buffer addr<47:32> Mailbox8 - DW Xfr Length (only valid for Type 7) Exit Parameters (Outgoing): Mailbox0 - (4000h) normal completion - (4002h) DMA error - (4005h) error during command execution - (4006h) if unsupported type or DW Xfr requested is too small ( 28DW <.. ) data got truncated Mailbox1 - If Outgoing Mailbox 0 is 4005h, then Outgoing Mailbox 1 will have the following sub-code: 0002h - No IOCB Mailbox8 - DW Xfr Data (should be 28 for typical PLOGI, only valid for Type 7)
The format returned is according to FC-LS-2 (Fibre Channel - Link Services - 2), rev.2.00 - FLOGI/PLOGI payload minus ELS command code. [ER66811]
* 8100 only. Added support for MPI heartbeat feature. Contact QLogic for details. [ER67656]
* 8100 only. Changes to support additional MPI mailbox commands in the range 136h to 150h. [ER67716]
* 2532/8100 CRC. Implemented CTIO Type CRC_2 and support DIF bundling on CTIO CRC IOCBs.[ER67727]
* 2532 SB2 only. Return the lower 16-bit of current RBC count in Receive IU and Add Buffer IOCBs. - For IOCB type 0x4D, the lower 16-bit of the counter is stored at offset 0x3E to 0x3F. - For IOCB type 0x4C, the lower 16-bit is stored at offset 0x1C to 0x1D. NOTE: This feature will be documented in the upcoming SB-4 spec. [ER68875]
Bug Fixes --------- * MID only. Do not report RSCN for VPs that have been disabled. Previously, the firmware generated 8015 AEN with an invalid vpindex. [ER62856]
* 2532/8100 CRC T10. Resolved bad FCP_DATA sequence due to incorrect re-initialization of the CRC context for Header mode. This affected T10 write commands with multiple FCP_XFER_RDYs. [ER67220]
* Removed zeroed optional association headers from RRQ payload. [ER67210]
* 24xx/2532 only. Corrected a problem in PLOGI ACC processing that could result in failure to respond to a subsequent PRLI. [ER67333]
* 8100 only. Changed login/logout IOCB processing to correctly format a LOGO sent to the fabric controller. [ER69214]
* Resolved a Fatal Firmware Error (8002h) due to a race condition when the exchange timer expires at the same time FCP_XFER_RDY is received. [ER69068]
* 8100 only. Changed link down handling to prevent a stall in received FCoE frame processing. [ER68914]
* Prevented Fatal Firmware Error (8002h) when processing an invalid ELS response type. This problem could occur if a switch sent an erroneous ELS response to a CT pass-thru request. [ER68488]
* 8100 only. Fixed a hang that could occur when processing a new request for an FCP2 capable device after a link status change. [ER68339]
* 2532/8100 only. Resolved intermittent Fatal Firmware Error (8002h) and FKA failures during Flash access. [ER68257]
* Modified RNID processing to correctly handle a response with a "Specific Identification Data Length" field of zero. [ER67623]
* 2532/8100 CRC T10. Changed buffer pointer validation to prevent erroneous 8002 system errors. [ER67568]
* 24xx/2532 only. Fixed a Fatal Firmware Error (8002h) caused by a problem cleaning up after a port discovery timeout. [ER67345]
* 8100 only. Prevented accidental overwrite of the PortName within a port descriptor data structure. Problem could occur during the execution of mailbox commands 30h, 31h, 51h, or 60h. [ER67181]
* Fixed 200ms delay for Command Type 6 IOCBs when residual underrun occurs, and FCP_RSP DMA is enabled. [ER67159]
* 8100 only. Resolved intermittent resource allocation failures in Read SFP mailbox command (31h). Improved failure sub code reporting in mailbox 1 for both Read(31h) and Write(30h) mailbox commands. [ER69146]
* Corrected ADISC ELS check for ELS passup and fixed potential bad pointer when building ELS frame. [ER67799]
* Fixed mailbox command Diagnostic Loop Back failures with Status 4005 and Subcode 0x17. [ER67690 8100 only]
* Fix erroneous discard of a valid FIP VLAN Notification frame when the frame does not have an IEEE 801.2 Q Tag and the FIP descriptor list length is greater than 8 (words). [ER67062 8100 only]
* 24xx/2532 only. Improved firmware handling of I2C SFP interface to better support some SFPs. [ER67479]
* 8100 only. Report NIC driver attached status in Get firmware State Mailbox Command (069h). For details, see the 8100 Series Fibre Channel Firmware Interface Specification, rev C. [ER65051]
* 8100 only. Firmware will return parameter error (4006h) if the Initialize Firmware Mailbox Command (060h) or Initialize Firmware Multiple IDs Mailbox Command (048h) specifies use of the optional Extended Initialization Control Block and provide a length of zero bytes. [ER65184]
* 8100 only. Changed the Perform Implicit LOGO Mailbox Command (072h) to allow the Perform Logout for All Ports across All FCFs option (bit 1 of incoming Mailbox Register 1) in single FCF configurations. [ER65220]
* Added a feature to reject PRLI from Fabric Control (FFFCxx) when target mode is disabled. To enable this option, set bit 7 of Mailbox 2 in the Set Additional Firmware Options Mailbox Command (0038h). [ER66061]
* 8100 only. Changed Get Link Status/Read Port Status Mailbox Command (06Bh) and Get Link Statistics and Private Data Mailbox Command (06Dh) to return counters consistent with the FCoE Link Error Status Block (LESB). Figure 3-4 of the 8100 Series Fibre Channel Firmware Interface Specification now contains the following counters: Link Failure Count, Virtual Link Failure Count, Missing FIP Keep Alive or Discovery Advertisement Count, Symbol Error During Carrier Count, Error'd Block Count, and Frame Check Sequence Error Count. [ER66125]
Bug Fixes --------- * MID only. Fixed an issue to prevent invalid VP misconfigurations that can result in a Fatal Firmware Error 8002h. [ER63706]
* 8100 only. Corrected ELS and BLS timeout units conversion when processing Mailbox Commands Get Timeout Parameters (0022h) and Set Timeout Parameters (0032h). [ER65155]
* 8100 only. Corrected an issue after External Loopback was performed that prevented FIP from completing. [ER65165]
* SB2 only. Corrected a condition in RRQ processing that could result in a Fatal Firmware Error (8002h) after receipt of an ABTS. [ER65232]
* Fixed an issue that caused a rediscovery of FCFs if FIP FLOGI timed out. [ER65757]
* Corrected a problem in target mode operation during confirmation processing that could result in a Fatal Firmware Error 8002h. [ER65415 8100 only]
* 24xx and 2532 only. Corrected auto-negotiation algorithm that would restore the link at the previous speed instead of the maximum speed. [ER65802]
* 8100 non MID only. Corrected a condition where the firmware state would not become Ready after switch port was shutdown and restored. [ER65980]
* Retry FIP VLAN Discovery after FIP Discovery Solicitation fails to find a primary FCF. [ER65980]
* Return LoginState in IO Parameter 1 when Login/Logout IOCB PRLI IO Parameter 0 = 4 (Command Failed). [ER66045]
* 2532 and 8100 MID only. Corrected VP Index range checking during processing of VP Control IOCB. [ER66068]
* Corrected Firmware Error reported during Purex IOCB processing if the Port Database for the target device had been initialized. [ER66082]
* 8100 only. Fixed detection of EP device. [ER66204]
* MID only. Corrected a problem which could result in LOGO sent with SID=000000 or incorrect reporting of VP status after a VP is disabled. [ER66553]
* 2532/8100 MIDQ only. Resolved a long delay in processing Command Type 6 IOCBs after link level fault injection. [ER66755]
* Fixed RISC pause condition when using T10 CRC with DIF_bundling. [ER66803]
* 2532 and 8100 only. Add DSD chaining support to command CRC type IOCBs. [ER62531]
* 8100 only. Updated Immediate Notify to reflect format described in the firmware spec. For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER63872, ER64455]
* 8100 only. When detected, report MPI configuration error and reason code in Get Firmware State Mailbox Command (069h). For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64342]
* 8100 only. Added new error completion codes to Restart MPI Mailbox Command (03Dh). For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64391]
* 8100 only. Implement SFP Read/Write Mailbox Commands (031h and 030h). For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64406]
* 8100 only. Modify Report ID Acquisition IOCB to return subcode for status 0x01, Unable to acquire ID, for FDISC. The subcode is returned at offset 10h. [ER64497]
* 8100 only. Update Get DCBX Parameters Mailbox Command (051h) to match latest spec. For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64672]
* 8100 only. Implement Get XGMAC Statistics Mailbox Command (07Ah). For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64673]
* 8100 only. Return SFP status information. See Asynchronous Event 8012h and Mailbox Commands 05Dh, 048h, 060h, and 069h. For details, see the 8100 Series Fibre Channel Firmware Interface Specification Rev C. [ER64732]
Bug Fixes --------- * 8100 only. Corrected handling of FLOGI Timeout and Reject processing by using Retry Count and Timeout as specified in Initialize Firmware Control Block. [ER63856]
* Corrected a condition where an Immediate Notify could be sent to the system driver when a VP is not configured for Target Mode operation. [ER64176]
* Corrected cleanup of pending Transmit Data requests across fault injection. [ER64251]
* 8100 only. Corrected a potential firmware hang condition after processing an ELS timeout or recovering from an internal error. [ER64265]
* SB2 only. Corrected a condition where the System Defined 1 field of an IOCB being returned to the system driver may be overwritten. [ER64315]
* 8100 only. Correct an issue with Flash Access Mailbox Command (003Eh). [ER64377]
* 8100 only. Corrected potential FCoE traffic stall after Port Reset completes. [ER64435]
* 8100 only. Fix FIP Failure to find FCF after a number of cable pulls/insertions into different FCF ports. [ER64454]
* 8100 only. Get FCF List Mailbox Command (050h) may fail to find valid FCF Index. [ER64507]
* 8100 only. Corrected false Loopback errors reported during internal and external tests. [ER64520]
* Corrected potential RISC pause when PUREX is enabled. [ER64520]
* 8100 only. Fixed incorrect Destination MAC address in FIP FLOGI request after an FCF Fabric name change. [ER64585]
* 8100 only. Allow primary port to be discovered via FDISC after it received a Clear Virtual Link or Fabric LOGO and another Virtual Port becomes the master. [ER64590]
* 2400/2532 only. Corrected a condition where a FCP RSP could be transmitted across a LIP and before the discovery timer expires in private loop topology. [ER64705]
* 8100 only. Corrected Firmware hang condition after receiving an ABTS. [ER64902]
From Version 4.06.00 to 5.00.00
Changes ------- * MID only. The firmware now returns a Port Unavailable (28h) Completion Status if the VP Index fails validation during a SCSI Task Management request. [ER62857]
* MID only. The firmware now allows Get VP Database Mailbox Command (49h) regardless of VP Status. [ER62858]
* SB2 only. The firmware now allows Get Link Status Mailbox Command (06bh) to complete even though Process Login has not completed. [ER63650]
Bug Fixes --------- * Fixed an issue to prevent initiating an LR upon a Transmit timeout while the firmware services other requests. [ER61666]
* Fixed an issue that delayed starting new Transmit requests if a Transmit error is pending. [ER61682]
* Corrected the auto-negotiation algorithm that could prevent the link from establishing when connected to a switch. [ER62000, ER62172]
* Corrected CTIO handling when link is down and CTIO received with an Exchange Address of FFFFFFFFh. [ER62715]
* MID only. Corrected various issues relating to VF support. [ER62798]
* Corrected issues found with VF and Fabric LOGO processing. Also corrected the valid VP Count range to 1-254. [ER62826]
* MID only. Corrected Source and Destination Address on an SCR retry. [ER62886]
* Completed various FCE tracing fixes. [ER62952, ER63400]
* Customer-specific fix. [ER63104]
* Corrected IDLE character to ArbFF when connected at 8Gb rate. [ER63488]
* Corrected an issue where a Mailbox or Mailbox IOCB request would not complete if a Fabric LOGO occurred. [ER63563]
* DISK CRC only. Corrected a RISC Pause condition reported during cable pull testing.[ER63564]
* Fixed an incorrect Response In Pointer reported in the RISC to Host Status Register when running in ZIO mode. [ER63790]
* 2532 MID multiple queue only. Corrected a link credit issue that resulted in decreased performance. [ER63913]
From Version 4.05.00 to 4.06.00
Changes ------- * 2532 only. Added support for Virtual Fabrics. Contact QLogic for API changes to support VFs. [ER60036, ER60250]
* MID only. Added feature to allow the firmware to perform SNS Login and SCR registration for virtual ports. This feature is enabled by setting bit 6 of the Options field during Initialize Firmware - Multiple IDs Mailbox Command (048h). Added the following status/ substatus values to Report ID Acquired IOCB:
VP Status Description --------- ----------- 3 SNS Timeout. See byte offsets 23:20 for Sub-status. 4 SNS LS_RJT (Reason/Explanation/Vendor Unique in IOCB byte offsets 23:20). 5 SCR Timeout. See byte offset 23:20 for Sub-status. 6 SCR LS_RJT (Reason/Explanation/Vendor Unique in IOCB byte offsets 23:20).[ER61930]
Bug Fixes --------- * MID only. Process received LOGO from F_Port. The associated Port Database Changed (8014h) asynchronous event will differ from a LOGO received from an N_Port as follows:
* 2532 only. Added the ability to specify a maximum Fibre Channel Link speed to be negotiated. This feature is enabled by bit 12 of the Initialize Firmware Control Block’s Firmware Option 3. When this bit is set to 1, firmware will negotiate the FC data rate from the given max speed specified by driver in bits 15-13 of the Initialize Firmware Control Block’s Firmware Options 3 field to two speeds down to what the SFP allowed. This option can also be set in the Data Rate Mailbox Command (05dh). When incoming mailbox 1 is set to 03h, firmware forces a loss of sync, restarts link initialization, and negotiates the FC data rate from the given max speed specified by driver in incoming mailbox 2 to two speeds down to what the SFP allowed. [ER60321]
* Allow system driver to send LOGO ELS via ELS Pass-Through IOCB using an N_Port Handle of FFFFh. [ER60400]
* MID only. Return Command Parameter Error (4006h) if the number of requested VP’s exceeds the limit when issuing Initialize Firmware – Multiple-IDs Mailbox Command (048h).
* 2432 only. Disable PCIe Completion Timeout. PCIe Completion Timeout has been disabled to address issues seen on certain systems where PCIe completion could take over 50ms. [ER61461]
Bug Fixes --------- * MID only. Corrected problems related to fault injection. [ER59740, ER60612]
* MID only. Various fixes to improve detection and processing of topology changes. [ER60127, ER60326, ER60610, ER60633]
* Corrected timing of when RRQ is issued after ABTS ACC is received. [ER60248]
* Corrected Out-of-Order handling of overlapped or repeating received XFR_RDY frames. [ER60318]
* 2532 Disk CRC only. Various Disk CRC changes to remove Fatal Firmware errors (8002h) being reported. [ER60336, ER61222, ER61223]
* MID only. Corrected a problem where a LOGO ELS could be sent to a port that was not logged in. [ER60565]
* MID only. Corrected a problem where a FLOGI/FDISC would not be sent to the switch after a previous FLOGI/FDISC completed with an ELS RJT. [ER60566]
* MID only. A PLOGI could be rejected for a Virtual Port even though the Primary Port parameters have not changed. [ER60568]
* MID only. Corrected a problem where an incorrect number of acquired AL_PAs could be reported during the LIRP and LILP phases of loop initialization. [ER60569]
* MID only. Login/Logout IOCB completion status was incorrect when no FLOGI ACC ELS had been received. [ER60571]
* Corrected a Fatal Firmware Error (8002h) when a CTIO IOCB with Confirmation Satisfied is received when the FCP_RSP has not been sent yet. The CTIO will be returned with a completion status of Invalid Request (06h). [ER60572]
* MID only. Corrected handling of incoming frames while waiting for LOGI ACC ELS for the primary port. [ER60576]
* Corrected a problem when attempting to abort an ELS Pass-Through operation when a PLOGI is received that changes the ports D_ID. [ER60637]
* Class 2 only. Corrected Fatal Firmware Error (8002h) reported when attempting to abort transmit operations. [ER60698]
* Corrected timer values used with link recovery. [ER60877]
* Improved handling of receiving an ABTS for a CT Pass-Through exchange. [ER61007]
* Corrected a problem with aborting IOs for the incorrect LUN when a LUN Level Task Management Function is active. [ER61155]
* MID only. Ensure that Buffer-Buffer Credits are not modified when processing FDISC or FDISC-ACC. [ER61187, ER61216]
* MID only. Correctly track changing of local 24-bit ID during cleanup. [ER61200]
* Handle race condition of completing transmit of PLOGI-ACC and receiving PRLI. [ER61465]
* Corrected failures reported by Loopback Mailbox Command (45h) and Echo Mailbox Command (44h). Added sub-error codes to Outgoing Mailbox 3 of the Echo Command to match the Loopback Command. [ER59630, ER59631]
Bug Fixes --------- * Disk CRC only. Corrected handling of frames received out of order in target mode. [ER58251, ER58760, ER58761]
* 2532 Disk CRC only. Corrected condition where the firmware would overwrite the IOCB Entry Status field when the device receives invalid IOCBs. [ER58532]
* 2532 Disk CRC only. Fixed a condition that could result in false DIF Errors when receiving runt block data. [ER58533]
* Disk CRC and 2532 only. Corrected an issue with multi-sequence DIF Remove functionality. [ER58752]
* 2532 only. Corrected a RISC pause that occurred when optional external memory is present. [ER58783]
* Corrected endianess of RNID user defined data field. [ER58802]
* Set correct Immediate Notify IOCB sub-code during fault injection. [ER58897]
* Improved handling of switches that transition link from F-FL-F when the device is directly connected to a switch port. [ER59100]
* Corrected issues relating to the EHAFT feature. [ER59279, ER59431]
* Corrected a target mode issue where an ATIO Queue update interrupt would not be posted when using a small ATIO queue. [ER59385]
* Corrected a Fatal Firmware Error (8002h) reported when ISP receives FCP_RSP with a payload length greater than 240 bytes. This problem would occur when Command Type 6 IOCB is used with the option to DMA the FCP_RSP payload to the host is enabled. [ER59503]
* 2532 only. Corrected the ending memory address reported by About Firmware Mailbox Command (08h) when external memory is present. [ER59793]
* 2532 only. Corrected the Report Link Statistics information for Loop topology. [ER59989]
* SB2 only. Corrected a problem where the firmware was clearing the N_Port Handle field of a SB2 Send IU IOCB. [ER60017]
* Disk CRC and 2532 only. Corrected false DMA error reported when using CTIO Type 7 IOCB (Target Mode) with Status Mode 2 selected. [ER60067]
* Fixed a problem that may cause a target level Task Management Function to fail while a LUN Level Task Management Function is outstanding. [ER60126]
* MID and 2532 only. Corrected a Fatal Firmware Error (8002h) reported after adapter side fault injection. [ER60256]
* Corrected a condition where the local loop would not recover after a transmit error was encountered.[ER60301]
From Version 4.03.01 to 4.03.02
Changes ------- * 2532 only. Enabled additional FC SerDes parameters to be set via Flash for mezzanine cards. [ER59755]
Bug Fixes --------- None
From Version 4.03.00 to 4.03.01
Changes ------- * 2532 only. Added support for mezzanine adapters Added a new bit, Embedded HBA, in Flash to indicate an adapter that does not use SFP+, and transmits FC signal over a copper backplane or mid-plane. [ER58635]
Bug Fixes --------- * 2432 only. Corrected a condition where Mailbox Commands issued to Function 1 would not complete after issuing Stop Firmware Mailbox Command (14h) to Function 0. [ER58617]
2. Known Issues
None.
3. Notices
Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
4. Contacting Support
For further assisance, contact QLogic Technical Support at: http://support.qlogic.com
Trademarks
Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
(c) Copyright 2013. All rights reserved worldwide. QLogic and the QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. qlgc_dd_fc_9_1_11_24_windows_32-64_chg
IBM Online SAS/SATA Hard Disk Drive Update Program Version 1.14.03-2 Build ID: SAS11403-2
NOTE TO SERVICE - Reference RETAIN TIPS H211424 & H211667 ******************************************************************* IBM SAS Hard Disk Drive Update Program Version 1.14.03-2 Critical Release Reference RETAIN TIP H211424 & H211667
This package includes updates to drives with product ID strings of:
SAS 3.5"
Initial Code Releases - ST1000NM0023, ST2000NM0023, ST3000NM0023, ST4000NM0023 to BC5B - ST2000NM0043, ST4000NM0043 to EC59 - WD1001FYYG-23S, WD2001FYYG-23S, WD3001FYYG-23S, WD4001FYYG-23S to XA35
Other - ST1000NM0001, ST2000NM0001 to BC4A - support persistent reservation - HUS723020ALS64, HUS723030ALS64 to J3K8 - servo adjustments
SAS 2.5"
Initial Code Releases - ST300MM0006, ST600MM0006, ST900MM0006 to B56H - ST300MM0026, ST600MM0026, ST900MM0026 to B568 - TXA2D20200GA6I, TXA2D20400GA6I, TXA2D20800GA6I, TXA2D21600GA6I to GB76 - see Retain Tip H211424. - HUC101212CSS60 to J2M7 - HUC101212CSS61 to N2M7 - T1200MM0007 to B576 - T1200MM0017 to E574 - ST600MX0001 to BH13 - WD3002BKTG-23E, WD6002BKTG-23E, WD9002BKTG-23E to ZC31 - ST9500431SS to ED12 - ST9146703SS to E536 - ST973352SS to E625 - ST9300553SS to E636 - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF - MK3001GRDB, MK6001GRDB, MK9001GRDB to SB35 - drive Que depth fix; see Retain Tip H211667. - HUC109030CSS60, HUC109060CSS60, HUC109090CSS60 to J2EF - HUC109030CSS61E, HUC109060CSS61E, HUC109090CSS61E to N2EF
Other - WD3001BKHG-23D, WD6001BKHG-23D, WD9001BKHG-23D to ZA32 - performance, non-critical fixes and robustness changes.
- ST9600204SS to B54A with maintainance fixes and performance improvements.
- MBD2147RC, MBD2300RC to SB1B - drive Que depth fix; - MBE2073RC, MBE2147RC to SC18 - drive Que depth fix; - MBF2300RC, MBF2600RC to SB2F - drive Que depth fix; - MK1401GRRB, MK3001GRRB to SC2E - drive Que depth fix; see Retain Tip H211667.
- ST9500620SS, ST91000620SS to BD2F - support persistent reservation and maintainance fixes.
SATA 3.5"
Initial Code Release - WD801ABYS-23C0A0, WD1601ABYS-23C0A0 to 06.06H05 - WD5003ABYX-23 to WC38 - added mfg. parameters. - WD2000FYYZ-23UL, WD3000FYYZ-23UL, WD4000FYYZ-23UL to WD36 - ST1000NM0033, ST2000NM0033, ST3000NM0033, ST4000NM0033 to BB58
Other
SATA 2.5"
Initial Code Release - SG9XCS2D50GEIBM to SE6H - WD3000BLHX-23V7BV to YA31 - SSDSC2BA200G3I, SSDSC2BA400G3I, SSDSC2BA800G3I to NA34 - SSDSC2BB120G4I, SSDSC2BB240G4I, SSDSC2BB400G4I, SSDSC2BB800G4I to NB34
Other - ST9250610NS, ST9500620NS, ST91000640NS to BE29 - maintainance updates. - MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA57 - added mfg. parameters.
SATA 1.8"
Initial Code Release - SSDSC1NA200G3I, SSDSC1NA400G3I to NA34 - SSDSC1NB080G4I, SSDSC1NB240G4I, SSDSC1NB400G4I to NB34
Other - MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA57 - added mfg. parameters.
=================================================================== Version 1.13.01 Build ID: SAS_113
NOTE TO SERVICE - Reference RETAIN H207993
******************************************* IBM SAS Hard Disk Drive Update Program Version 1.13.01 Critical Release Reference RETAIN H207993
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- HUS723020ALS64 to J3K7 Additions to VPD information used by manufacturing and fixes for overall robustness.
- HUS723030ALS64 to J3K7 Initial Code Release
- ST31000424SS, ST32000444SS to BC2D - ST1000NM0001, ST2000NM0001 to BC49 Fixes for overall robustness.
- ST33000650SS to BC3E Initial Code Release
SAS 2.5"
- MK1401GRRB, MK3001GRRB to SC29 Fixes for overall robustness.
- MBF2300RC, MBF2600RC to SB2C Initial Code Release.
- ST9300605SS, ST9600205SS, ST9900805SS to B55D ST9146853SS, ST9300653SS to B63B ST9500620SS, ST91000640SS to BD2E ST9300505SS, ST9600105SS, ST9900705SS to E557 ST9146753SS to E636 Additions to VPD information used by manufacturing and fixes for overall robustness.
SATA 3.5"
- ST500NM0011, ST2000NM0011, ST1000NM0011 to BB4A ST3500514NS, ST31000524NS, ST32000644NS to BB2C Reliability improvements, Additions to VPD information used by manufacturing
- ST33000650NS to BB3A Initial Code Release
- WD5003ABYX-23 to WC36, WD1003FBYX-23Y7B0 to WB35, WD2003FYYS-23W0B0 to WA35 Reliability improvements, Additions to VPD information used by manufacturing
- HUA723020ALA640 to MK7OA910 Additions to VPD information used by manufacturing.
- HUA723030ALA640 to MKAOA910 Initial Code Release
- HUA722050CLA330, HUA722010CLA330 to A3PH Initial Code Release
SATA 2.5"
- TE22D10100GE8IBM to SR3B Initial Code Release
- MTFDDAK064MAR-1J1AA, MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA, MTFDDAK512MAR-1K1AA to MA55 Initial Code Release
- ST9250610NS, ST9500620NS, ST91000640NS to BE28 Fixes for overall robustness.
SATA 1.8"
- MTFDDAA064MAR-1J1AB, MTFDDAA128MAR-1J1AB, MTFDDAA256MAR-1K1AB, MTFDDAA512MAR-1K1AB to MA55 Initial Code Release
- TX21B10100GE8IBM, TX21B10200GE8IBM, TX21B10400GE8IBM to SP3A Initial Code Release
Version 1.12.01 Critical Release Reference RETAIN #H207740
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST1, VPCA600900EST1 to A3C4, Corrects firmware bug that may cause data corruption. For further information, please refer to Retain Tip H207740.
- ST3300657SS, ST3450857SS, ST3600057SS to BA5A VPCA300900EST1, VPCA600900EST1 to A3C2 Additions to VPD information used by manufacturing
- ST3750630SS, ST31000640SS to BC1I ST31000424SS, ST32000444SS to BC2C Mode Page change to address performance issues under certain system configurations
- ST33000650SS to BC3D ST1000NM0001, ST2000NM0001 to BC48 Protection Information Fix - see Retain Tip H206140
- HUS723020ALS64, HUS723030ALS64 to J26C Initial Code Release
SAS 2.5"
- ST9300603SS, ST9146803SS to B53E ST9600204SS to B549 Additions to VPD information used by manufacturing
- ST9300605SS, ST9600205SS, ST9900805SS to B55C ST9146853SS, ST9300653SS to B63A ST9500620SS, ST91000640SS to BD2C ST9300505SS to E555 ST9146753SS to E635 Protection Information Fix - see Retain Tip H206140
- ST9600105SS, ST9900705SS to E555 Inital Code Release
- HUC106030CSS60, HUC106060CSS60 to D3A6 Performance improvements, critical fixes for Protection Information (PI) operation - see Retain Tip H206140
- MK1401GRRB, MK3001GRRB to SC27 Additions to VPD information used by manufacturing
- WD9001BKHG-23D, WD6001BKHG-23D, WD3001BKHG-23D to ZA31 Initial Code Release
SATA 3.5"
- WD2502ABYS-23B7A0 to 02.03B08 WD1602ABYS-23B7A0 to 02.03B07 Critical fix to address premature drive failures.
- ST3500514NS, ST31000524NS, ST32000644NS to BB2A ST33000650NS to BB38 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB47 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
- HUA723020ALA640 to MK70A900 HUA723030ALA640 to MKA0A900 Initial Code Release
SATA 2.5"
- ST9160511NS, ST9500530NS to BE1A - ST9250610NS, ST9500620NS, ST91000640NS to BE25 Fixes a potential, but rare data corruption issue which requires a background reallocation that exceeds the error recovery timer.
SSD
- TX21B10200GE1IBM, TX21B10400GE1IBM, TX21B10100GE8IBM to PRO6SP36 TE22D10100GE8IBM to PRO6SR36 Initial Code Release
- MTFDDAK128MAR-1J1AA, MTFDDAK256MAR-1K1AA to MA52 Initial Code Release
- MTFDDAA512MAR-1K1AB, MTFDDAK064MAR-1J1AA, MTFDDAK512MAR-1K1AA, MTFDDAA064MAR-1K1AB, MTFDDAA128MAR-1K1AB, MTFDDAA256MAR-1K1AB to MA52 Fixes SMART attribute 190 (Current Temp) which caused warning messages with some versions of Linux
- STEC MACH8 IOPS to 2804 STEC M8PSB2 T4 to SM06 Additions to VPD information used by manufacturing Fixes potential drive failure if power loss occurs during firmware update.
- ST33000650SS to BC3A ST1000NM0001, ST2000NM0001 to BC44 Additions and corrections to VPD information used by manufacturing
SAS 2.5"
- ST9300605SS, ST9600205SS, ST9900805SS to B559 ST9146853SS, ST9300653SS to B637 ST9500620SS, ST91000640SS to BD29 ST9300505SS to E553 SST9146753SS to E633 HUC106030CSS60, HUC106060CSS60 to D390 Additions and corrections to VPD information used by manufacturing
- MK1401GRRB, MK3001GRRB to SC23 Fixes a pottential data corruption bug if there is an unexpected power loss.
SATA 3.5"
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 ST3500514NS, ST31000524NS, ST32000644NS to BB29 ST33000650NS to BB36 ST1000NM0011, ST2000NM0011, ST500NM0011 to BB46
SATA SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB6C SG9XCS2D200GEIBM to SA03SE6C Fix for potential hang during an unexpected power cycle
MTFDDAK128MAR-1JAAB, MTFDDAK256MAR-1JAAB to MA44 Initial Release
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA600900EST1 to A3C0 Correction to VPD information used by manufacturing
- ST31000424SS, ST32000444SS to BC2B Fixes to improve robustness from certain read errors due to encroachment
- ST33000650SS to BC37 Fixes to improve overall robustness.
- ST1000NM0001, ST2000NM0001 to BC42 Inital Release
SAS 2.5" (SFF)
- ST9300605SS, ST9600205SS, ST9900805SS to B556 - ST9146853SS, ST9300653SS to B635 Fixes to improve overall robustness.
ST9300505SS to E552 ST9146753SS to E632 Initial Release
- ST9500620SS, ST91000640SS to BD26 Improve general robustness and added support for DPICZ
- HUC106030CSS60, HUC106060CSS60 to D340 Improve general robustness
- MBF2300RC, MBF2600RC to SB28 Improves performance in certain benchmarks
SATA 3.5"
- ST33000650NS to BB34 Fixes to improve overall robustness.
- ST1000NM0011, ST2000NM0011, ST500NM0011 to BB45 Initial Release
- ST3500514NS, ST31000524NS, ST32000644NS to BB29 Fixes for intermittent drive hangs
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB15 Added enhancement for improved robustness
SATA 2.5"
- ST9250610NS, ST9500620NS, ST91000640NS to BE24 Initial Release
- ST9160511NS, ST9500530NS to BE19 Fixes for overall robustness.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2765 STEC M8PSB2 T4 to SM05 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS2D200GEIBM to SA03SE6C Fixes default drive VPD information for manufacturing, the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
SATA 1.8" SSD
- STEC M8PSB1 to 0409 STEC M8PSB1 T4 to SM16 Fixes potential drive lock up during cold or warm boots Fixes issues with RHEL 6.x installation
- SG9XCS1B50GMIBM to SA03SB6C SASG9XCS1F200GEIBM to SA03SB6C Fixes potential drive lock up during cold or warm boots and the default LED behavior on certain systems and fixes issues with client install thru VMWare 5.x
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST31000424SS, ST32000444SS to BC28 Added enhancement for improved RV robustness
- MBE2073RC, MBE2147RC to SC17 - MBA3073RC, MBA3147RC, MBA3300RC to SA0A Added VPD changes for manufacturing
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53C ST9600204SS to B548 SST973452SS, ST9146852SS to B62C CBRCA146C3ETS0, CBRCA300C3ETS0 to C610 Added fixes for overall drive robustness
- MBD2147RC, MBD2300RC to SB1A Added VPD changes for manufacturing Addresses issues seen with DSA HDD Diagnostic test.
- MBF2300RC, MBF2600RC to SB25 Addresses issues seen with DSA HDD Diagnostic test.
- ST9500620SS, ST91000640SS to BD22 HUC106030CSS60, HUC106060CSS60 to D2F8 Inital Release
SATA 3.5"
- WD2502ABYS-23B7A0 , WD1602ABYS-23B7A0 to 02.03B07 Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB14 ST3500514NS, ST31000524NS, ST32000644NS to BB28 Added enhancement for improved robustness
- WD5003ABYX-23 to WC31 Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V10 (Critical) Addresses firmware issues that may cause a drive to be marked defunct prematurely under certain application workloads.
- ST9250610NS, ST9500620NS, ST91000640NS to BE21 Initial Release
SATA 2.5" SSD
- STEC MAC8 IOPS to 2732 STEC M8PSB2 T4 to SM04 Addresses an issue installing RHEL 6.0 onto this drive.
SATA 1.8" SSD
- SG9XCS1B50GMIBM, SG9XCS1F200GEIBM to SA03SB63 Addresses rare issue where the drive may not being seen on power up.
- STEC M8PSB1 to 0408 STEC M8PSB1 T4 to SM15 Addresses an issue installing RHEL 6.0 onto this drive.
- ST373455SS, ST3146855SS, ST3300655SS to BA2D - ST373355SS, ST3146755SS, ST3300555SS to BA38 - ST3146356SS, ST3300656SS, ST3450856SS to BA4C - ST3300657SS, ST3450757SS, ST3600057SS to BA58 - ST3750630SS, ST31000640SS to BC1G - ST31000424SS, ST32000444SS to BC26 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- MBA3073RC, MBA3147RC, MBA3300RC to SA08 This code corrects a firmware bug that may cause the drive to not come ready on a cold boot.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52B - ST936751SS, ST973451SS to B617 - ST9146803SS, ST9300603SS toB53B - ST9600204SS to B546 - ST973452SS, ST9146852SS to B629 - ST9300503SS to E536 - ST9146752SS to E625 - ST9500430SS to BD14 (All Above Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
SATA 3.5"
- ST3500514NS, ST31000524NS, ST32000644NS to BB26
- WD2003FYYS-23W0B0 to WA32 - WDC WD1003FBYX-23Y7B0 to WB31 Initial release
SATA 2.5" SSD
- STEC MACH8 IOPS to 2582 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
SATA 1.8" SSD
- STEC M8PSB1 to 0405 (Critical) Corrects firmware bug that may cause data corruption. For further information, please refer to retain tip H197650.
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- VPCA300900EST1, VPCA450900EST, VPCA600900EST1 to A3B8 Initial Release
- VPBPA300C3EST1 to A529 Initial Release
- ST3300657SS, ST3450757SS, ST3600057SS to BA56 (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST31000424SS, ST32000444SS to BC21 Initial Release
SAS 2.5" (SFF)
- ST9300603SS, ST9146803SS to B53A (Critical) Performance improvements under certain workloads. Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST9600204SS to B544 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST973452SS, ST9146852SS to B626 Performance improvements under certain workloads.
- ST9500430SS to BD13 Performance improvements under certain workloads
- ST9300503SS to E534 and ST9146752SS to E623 Performance improvements under certain workloads.
- MBD2147RC, MBD2300RC to SB19 (Critical) MBE2073RC, MBE2147RC to SC16 (Critical) Corrects a firmware bug that erroneously reported medium errors which may cause the drive to report PFA alerts and in some cases be marked offline
SATA 3.5"
- WDC WD2502ABYS-23B7A0, WD2502ABYS-23B7A0, WD802ABYS-23B7A0, WD1602ABYS-23B7A0 to 02.03B05 (Critical) Corrects a firmware bug that may cause the drive to not come ready on a warm or cold reboot.
- ST3500514NS, ST31000524NS, ST32000544NS to BB26 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- ST3250310NS, ST3500320NS, ST3750330NS, ST31000340NS to BB13 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382.
- HUA722020ALA330 to JKAOA3GA HUA722050CLA330 to JP2OA3GB HUA722010CLA330 to JP4OA3GB Initial Release
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V09 (Critical) This code corrects an additional issue where the drive may be marked defunct.
- ST9160511NS, ST9500530NS to BE18 (Critical) This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. For further information, please refer to retain tip H197382. Also improves performance under certain workloads.
SATA 2.5" SSD
- STEC MACH8 IOPS to 2366 (critical) Corrects firmware bug that may cause degraded performance and in some cases the drive may not come ready after a warm or old boot.
SATA 1.8" SSD
- STEC M8PSB1 to 0404 Turns the default for write cache off Initial Release
IBM SAS Hard Disk Drive Update Program Version 1.06 (Critical)
Added support for the following controllers:
- IBM ServeRAID BR10il SAS controller v2 (49Y4731) - IBM ServeRAID M1015 SAS controller (46M0831) - IBM ServeRAID M5015 SAS controller (46M0829) - IBM ServeRAID M5014 SAS controller (46M0916)
This package includes new updates to drives with product ID strings of:
SAS 3.5"
- ST373455SS, ST3146855SS, ST3300655SS to BA2A ST373355SS, ST3146755SS, ST3300555SS to BA36 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- ST3750630SS, ST31000640SS to BC1E ST3146356SS, ST3300656SS, ST3450856SS to BA4A This code address an issue where the drive may report an erroneous hardware error to the controller.
- MBA3073RC, MBA3147RC, MBA3300RC to SA07 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST3300657SS, ST3450757SS, ST3600057SS to BA52 NOTE: This is the first code release to be included in the hard drive update package.
SAS 2.5" (SFF)
- ST973402SS, ST9146802SS to B52A ST936751SS, ST973451SS to B616 (Critical) These codes addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632.
- MBB2073RC, MBB2147RC to SB07 MBD2147RC, MBD2300RC to SB17 MBE2073RC, MBE2147RC to SC14 CBRCA146C3ETS0, CBRCA300C3ETS0 to C370 This code improves sequential write performance under certain workloads when write cache is turned on.
- ST9500430SS to BD11 This is the first code release to be included in the hard drive update package.
SATA 3.5"
- WD2003FYYS-23T8B0 to 01.00D04 This is the first code release to be included in the hard drive update package.
SATA 2.5"
- WD3000BLFS-23YBU0 to 04.04V08 (Critical) This code corrects an issue where the drive may generate a false PFA alert. It also corrects an issue where the drive may be marked defunct
- ST9160511NS, ST9500530NS to BE16 This is the first code releases to be included in the hard drive update package.
=============================================================== IBM SAS Hard Disk Drive Update Program Version 1.05
SAS 2.5" (SFF)
ST9xxxx51SS to B616 ST9xxxx02SS to B52A - This code improves the robustness of write cache operations.
ST9xxxx52SS to B624 ST9xxxx03SS to B536 - This code improves the robustness of write cache operations and sequential write performance when write cache is enabled
MBD2xxxRC to SB14 - Initial release
SAS 3.5"
ST3xxxxx6SS to BA49 ST3750630SS to BC1D - This code improves the robustness of write cache operations.
SATA 3.5"
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V05 - Adjusted PHY setting for better signal quality margin.
SATA 2.5" SSD
STEC MACH8 IOPS to 2269 GBRL0xxxxx to 4.17 GBRLBxxxxx to 4.26 - The new firmware will correct a rare data error condition in the drives where invalid data may be passed to the system without any error condition flagged.
Due to the severity of this potential issue, IBM strongly recommends applying this firmware as soon as possible.
For further information, please refer to retain tip H195663. =================================================================
IBM SAS Hard Disk Drive Update Program Version 1.04
SAS 2.5" (SFF)
CBRBAxxxxxx to C49B - Modified VPD for JSxx Blades
MBBxxxxxx to SB05 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
MBC2073RC to SC04 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
SAS 3.5"
MBAxxxxxx to SA06 - Fixed a performance issue when synchronizing or rebuilding an array when used in a LSI 1064 based SAS controller
ST3xxxxx6SS to BA48 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
ST3750630SS to BC1A - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- Fixes a hang condition during failover operation on a Bladecenter-S chassis with an RSSM controller.
BBAxxxxxx to BH0K - Fixes an issue where a drive may prematurely report a PFA trip
GNAxxxxxx to BH0J - Fixes an issue where a drive may prematurely report a PFA trip
SATA 3.5"
ST31000340NS, ST370330NS, ST3250310NS, ST3500320NS to BB12 - This code addresses a rare potential for data corruption. For this issue to occur, the drive write cache must be enabled. When a write is issued while the drive write cache is enabled and a read-verify is performed immediately afterwards, undetected data corruption can occur. For further information, please refer to retain tip H194632
- This code addresses a rare potential for data loss. After a power cycle, the drive will no longer be available and becomes unresponsive. Data will become inaccessible due to the drive not responding. For further information, please refer to retain tip H194623.
WDC WD2502ABYSxxxxx tp 02.03B04 - Fixes incorrect VPD data
SATA 2.5"
WD3000xxxxx to 04.04V04 - Fixes a Critical issue - IBM recommends a backup of the data on the drive before attempting to update the firmware. This is a fix for an issue where data required for spinup of the drive may be overwritten rendering the drive inoperable on a subsequent warm or cold system reboot.
- Fixes a issue with an internal timer that may cause drive to go offline when used in a non-raid environment.
IBM SAS Hard Disk Drive Update Program Version 1.03
Added support for the following controllers:
IBM ServeRAID MR10il SAS Controller IBM ServeRAID MR10is SAS Controller IBM ServeRAID BR10i SAS Controller IBM ServeRAID BR10il SAS/SATA Controller IBM SAS/SATA RAID Kit IBM SAS Expansion Card (CFFv) for IBM BladeCenter IBM SAS Connectivity Card (CFFv) for IBM BladeCenter
New updates to drives with product ID strings of:
SAS 2.5" (SFF)
ST9146802SS, ST973402SS to B529 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST936751SS, ST973451SS to B615 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
CBRBAxxxxxx to C495 - Initial release
MBBxxxxxx to SB04 - Initial release
MBC2073RC to SC03 - Initial release
SAS 3.5"
VPBAxxxxxx to A496 - Added support for JS2x Blades in a Bladecenter-S chassis
ST3146855SS, ST3300655SS, ST373455SS to BA29 - Added support for JS2x Blades in a Bladecenter-S chassis - Picked up the latest network roll of firmware fixes to address some unexpected system hangs,
ST3450856SS to BA47 - IBM was notified by our vendor that there is a defect in a level of firmware used in the IBM 450GB 15K SAS 3.5" HS HDD (PN 41Y8454) in option 42D0519, which under certain conditions may lead to data being written or read back incorrectly on the drive. IBM has worked closely with the vendor to identify the problem and developed a firmware fix to resolve the problem. Customers should upgrade to firmware level BA47
MBAxxxxxx to SA05 - Initial release
ST3750630SS to BC17 - Initial release
SATA 3.5"
ST3250620NS, ST3500630NS, ST3750640NS to 3.AEV
ST3250621NS, ST3500631NS, ST3750641NS to 4AEV
ST31000340NS, ST3750330NS, ST3250310NS, ST3500320NS to BB10 - Initial release
HUA721050KLA330, HUA721075KLA330, HUA721010KLA330, to AB4A - Initial Release
SATA 2.5" SSD
GBRL001xxx, GBRL0031xxx to 4.14 - corrects intermittent hangs during operations =============================================================
IBM SAS Hard Disk Drive Update Program Version 1.02
Support of ServeRaid 8s Raid controller Support of ServeRaid 10i Raid controller Support of ServeRaid 10k Raid controller Support of ServeRaid 10m Raid controller Support of LSI 1078 SAS controller Support of SATA drives attached to SAS controllers
Support and updates to drives with product ID strings of:
VPAxxxxxx to A650 Change to improve performance in sequential write workloads Improvements to internal drive logging and media checking. Critical Fix: This code addresses a rare potential for data loss This code update should be applied to prevent the event from occurring.
ST340XXXAS and ST380XXXAS to 3.48 Fix to address Read Log Command abort error.
ST340XXXAS, ST380XXXAS and ST3160XXXAS to 3.05 Fix to address intermittent hard drive no-shows after system comes out of hibernation.
ST3500641NS to 3.AES Changes to the refresh rate of the DRAM used on the drive.
ST3500640NS to 3.AEJ Initial release.
HDTXX... & HDSXX... codes go to Masked ROM version. HDS725050KLA360 to AQ1A to also Fix an issue that occurs while running in NCQ mode with write cache disabled.
ST3xxxx4SS to BA26 Improves intialization times with some ServeRaid controllers Performance improvements under some sequential workloads.
ST3xxxx5SS to BA35 Improves intialization times with some ServeRaid controllers
ST9xxx51SS to B612 Intial release of firmware
ST9xxxx2SS to B526 Improves intialization times with some ServeRaid controllers
MAUxxxx and MAXxxxx Added support for new SAS features required by new SAS controllers.
IBM SAS Hard Disk Drive Update Program Version 1.01 Please refer to RETAIN tip H186019.
Support of ServeRaid 8e Raid controller Support of ServeRaid 8k Raid controller Support of ServeRaid 8l Raid controller Support of on-board LSI 1064 controller IBM MegaRaid 8480 Raid Controller
Firmware updates to drives with Product ID strings:
GNAxxxx and BBAxxxx to BH0G Picks up the latest network roll of firmware fixes to improve performance under some sequential workloads and improvements to signal quality parameters.
ST9xxxx to B51D amd ST3xxxx to BA18 Picks the latest network roll of firmware fixes to address unexpected system hangs and some performance improvements.
MAVxxxx to S116 and MAYxxxx to T107 Picks up the latest network roll of firmware fixes and to improve signal quality parameters.
MAXxxxx to T904 Initial release ============================================================
IBM SAS Hard Disk Drive Update Program Version 1.00 Initial Release
Support of Adaptec 48xxx based controllers Support of ServeRaid 8i Raid controller Support and updates to drives with product ID strings of: ST936701SS ST973401SS ST336754SS ST373454SS GNAxxxxx BBAXXXXX
ibm_fw_hdd_sas-1_14_03-2_windows_32-64_chg
Intel® Chipset Device Software 9.2.3.1020 For JakeTown and Patsburg
Release Notes
August 9, 2011
Microsoft Windows* 2000 Microsoft Windows* XP Microsoft Windows* XP Professional x64 Edition Microsoft Windows* Server 2003 Microsoft Windows* Server 2003 x64 Edition Microsoft Windows* Vista Microsoft Windows* Vista x64 Edition Microsoft Windows* Server 2008 Microsoft Windows* Server 2008 x64 Edition Microsoft Windows 7 Microsoft Windows 7 x64 Edition Microsoft Windows Server 2008 R2 X64
DISCLAIMER: Information in this document is provided in connection with Intel® products. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppels or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty relating to sale and/or use of Intel products, including liability or warranties relating to fitness for a particular purpose, merchantability or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Intel may make changes to specifications and product descriptions at any time, without notice. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Notice: The Intel® Chipset Device Software may contain design defects or errors
described as "known issues" which may cause the product to deviate from expected performance. Current characterized known issues are documented in this update.
Revision History
Date Driver Revision Draft/Changes August 2011 9.2.3.1020 See below
Intel® Chipset Device Software Support
The Intel® Chipset Device Software contains support for the following Intel Chipsets:
• Patsburg and Jaketown • Intel® 5 Series Chipsets • Intel® 3400 Series Chipsets • Intel® 4 Series Chipsets • Intel® 3 Series Chipsets • Intel® 900 Series Chipsets • Intel® 800 Series Chipsets • Intel® Server/Workstation Chipsets Supported Operating Systems
The Intel® Chipset Device Software is validated on the following Microsoft operating systems.
• Microsoft Windows* 2000 • Microsoft Windows XP • Microsoft Windows XP Professional x64 Edition • Microsoft Windows Server* 2003 • Microsoft Windows Server* 2003 x64 Edition • Microsoft Windows Vista* RTM and SP’s • Microsoft Windows Server* 2008 • Microsoft Windows Server* 2008 x64 Edition • Microsoft Windows 7 • Microsoft Windows 7 x64
New Features, Fixes & Changes
Features Added WHQL -9.2.3.1020 – 08/09/2011 Features Added in Alpha 9.2.3.1010 – 02/28/2011 Description Added support for Waimea Bay platform Features Added in Alpha 9.2.3.1010 – 01/14/2011 ID Description 1 Removed Commented SMB from PatCore 2 Fixed spelling of Controller in AHCI and IDE inf files Features Added in Alpha 9.2.3.1009 1 Added 1D41 LPC device Features Added in Alpha 9.2.3.1008 1 Changed ® to (R) 2 3C00 changed to No_Drv for the “A” stepping in order for a BOSD not to occur 3 Removed 3C60 and 3C61 4 Added 1D76 and 1D77 5 Added Audio INF (1D20) Features Added in Alpha 9.2.3.1004 1 Removed commented out Devices from JakeTown.Inf 2 Changed Installer Version to 1.1.32 (Fixes –overall switch and 2nd install of filtered INF files) Description
WHQLed
Features Added 9.2.3.1017 – 06/17/2011 Description
1. Updated Name String on 1D3E 2. Added HECI INF Features Added WHQL9.2.3.1016 – 04/22/2011 Description
WHQLed to 1.6
Features Added in Beta 9.2.3.1015 – 04/07/2011 Description
1. Jaketown name changes 2. Updated Installer with Klockwork scan fixes 1.1.42 3. Updated Official Branding For Patsburg 4. Moved to Installer Label 1.1.36 a. Updated extractdriver function b. Creates MUP.xml (packageversion not correct)
Features Added in Alpha 9.2.3.1003 ID 1 2 3 Description JakeTown.inf: commented out PCI devices 3C00-3C0F Changed 3C88 to 3C90 Added 3C44 QPI Link Added 3CE4 R2 PCIe Features Added in Alpha 9.2.2.1002 Commented out 3C02 from jaketown.inf Features Added in Alpha 9.2.2.1001 Added JakeTown.inf Updated all Patsburg related INF
Software Sightings and/or Known Issues
ID Information 1 After version 9.2.3.1004 B0 must be used (jaketown B0 should be used with Patsburg B0)
intel_dd_inteldp_9_2_3_1020_winsvr_32-64_chg
Broadcom (R) Corporation Broadcom Ethernet Software Kit RELEASE 16.4.0.2 from Gold CD 16.4.4.4 (March 14, 2014)
RELEASE NOTES
Summary ======= - Gold Update Release for the Broadcom 16.4 project.
Caveats ======= - tg3 final pass testing is not complete yet. Estimated completion is March 10, 2014. - The AIM was not tested in EFI due to no available tool. 70995 - Agentless Upgrade for Mustang and Kestrel LOM support is included in this release but that functionality is untested by PQA. For Mustang adapter this new UEFI requires IMFW 1.08 release to be present to operate correctly
Highlights ========== 71959 - Agentless Phase 1 support for Mustang mezz and Kestrel LOM. 54220 - 5719 Silent Data Corruption Errata for 5719 addressed completely for VMware. 72462 - Potential Windows bugcheck due to BASP spinlock deadlock. 71966 – IBM customer PMR 87165,070,724 - NIC link down on AngelShark with W2K8R2. 68994 - Remote KVM lost connection while running the power cycle stress tested on IBM JinHu system 70795 - XB191768 - IMM VLAN function can work on early post time and OS.
Version history between CDs v16.4.4.4 release and previous CD v16.4.4.1 release: ====================================================++++++================
CD Release v16.4.4.4 Previous v16.4.4.1 Product Version Version
Windows Server 2008/2012/2012R2 x64 Driver 16.4.0.2* 16.4.0.1 Windows Server 2008/2012/2012R2 IA32 Driver 16.4.0.2* 16.4.0.1
Note: An asterisk (*) following a version number represents a certified driver.
Windows 2000/2003 is not Supported with this package.
This release contains the following software programs:
NetXtreme Gigabit Ethernet NDIS6.x for Microsoft Windows 2008/2012/2012R2, 32 bit extensions - b57nd60x.sys NetXtreme Gigabit Ethernet NDIS6.x for Microsoft Windows 2008/2012/2012R2, 64 bit extensions - b57nd60a.sys
* Third-party trademarks and copyrights are the property of their respective owners.
Broadcom, Broadcom Advanced Server Program, Broadcom Advanced Server Control Suite, and Smart Load Balance are registered trademarks of Broadcom Corporation.
Firmware version: 4.6.281.21 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - OCe10 VFA CNAs stuck in "Switch Independent Mode" - Port Identification fails on Port 1 under uEFI menu for PCIe rack VFA
Incremental Interoperability: - Emulex Dual Port 10GbE SFP+ VFA IIIr for IBM System x - Emulex Dual Port 10GbE SFP+ Embedded VFA IIIr for IBM System x - IBM Flex System CN4054R 10Gb Virtual Fabric Adapter - IBM Ivy Bridge CPU Based Servers
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.281.8 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - HW iSCSI offload is now supported in UFP Mode (UFP limited to IBM Flex) - Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs. - When using Config Patterns with virtual MACs the bandwidth settings are are intermittently reset after some number of server reboots.
Incremental Interoperability: - IBM Flex System Fabric SI4093 System Interconnect Module - IBM Flex System EN6131 40Gb Ethernet Switch - IBM Flex System x222 10Gb Virtual Fabric LOM - SLES 11.3 on IBM System x and BladeCenter - Complete NIC/iSCSI/FCoE support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.166.9 (supported on IBM System x & BladeCenter)
Problems Fixed: - When connected to Cisco Nexus 4k and 5k switches, the virtual link may not recover on a switch port bounce (shut/no shut) in an ESXi environment. A switch port re-bounce will recover the link.
- When connected to Cisco Nexus 4k and 5k switches, OneCommand Manager reports CRC's and there is poor network performance in an ESXi environment
- In some cases of heavy traffic or broadcast storm, users can experience a loss of ethernet connectivity or PSOD (ESXi)
Incremental Interoperability: - ASU/Config Pattern configuration for iSCSI and FCoE (BE3) - UFP for iSCSI (BE3) - Support for using 10Gb ports with legacy 1Gb switches installed in a BladeCenter-S chassis or MSIM/MSIM-T expansion units in a BladeCenter-H or -HT chassis - Update Express System Packs now support Linux errata kernels - ESXi 5.1
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware Version: 4.4.180.3 (Previously supported on IBM Flex)
Problems Fixed:
- 10Gb ports intermittenly linking at 1Gb speed with the IBM Flex System Fabric EN4093/EN4093R 10Gb Scalable Switch. - Switch Configuration after an erase configuration is not reflected after reboot - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - When adding an iSCSI hardware target in UEFI through discovery login, the boot target setting is ignored.
Interoperability since previous release:
- UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility - IBM Universal Configuration Manager for Ethernet - IBM Unified Fabric Protocol - Ability to assign Switch Agnostic VLAN IDs without intermediate reboot - Changes to Personality or Multichannel in PXESelect allows further changes to be made w/o reboot - Support for IBM Flex System Fabric CN4093 10Gb Converged Scalable Switch
Known Issues:
- HW iSCSI offload is not currently supported in UFP mode
Firmware Version: 4.1.422.8 (Previously supported on IBM Flex)
Problems Fixed:
- PHY Loopback fails on 10G ports - RH 6.2 and W2k8 servers crashed after shut/no shut the switch port with FCoE connection and 50 vlans configured - DSA: NIC physical loopback test fails in Command and GUI mode - Firmware update fails to update all VPD Code Level fields - DCBX does not converge with FW 4.1.422 on Cicso 5k.
Interoperability Since Previous Release:
- Support for IBM Flex System x440 10Gb Virtual Fabric LOM
Firmware Version: 4.1.422.0 (Previously supported on IBM Flex)
Problems Fixed:
- SR IOV: Unable to ping IPV6 from DUT VF to Peer VF - Reading VPD from BE3 timesout making SR IOV fail in newer kernels - 1Gb devices are being suppressed by kernel during the PCI probe in SLES11 SP2 - MAC Loopback fails when Mgmt Adapter Creation fails - Failure of MAC loopback test after firmware update and warm reboot - Suppress efat dump mailbox commands in the efat dump log - Running ethtool with BE3 takes longer than expected after cable pull - Out of Order CQEs - TRACE_LOG function not printing the messages for some of the VF's - esx4/5 issue. svc target cannot be configured properly - RSCN is not generated by switch when a driver restarts - Port Link stays up even after switch removed
Interoperability Since Previous Release:
- Support for IBM Flex System EN4054 4-port 10Gb Ethernet Adapter - Support for IBM Flex System CN4054 10Gb Virtual Fabric Adapter - Support for IBM Flex System x240 10Gb Virtual Fabric LOM - Support for IBM Flex System Manager 10Gb Virtual Fabric LOM
Firmware Version: 4.2.433.3 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup. - Under high network stress, NMI errors can be seen with x3690 X5 and x3850 X5 - 10GbE ports running at 1GbE speed 10% below wirespeed at certain block sizes. - Unable to perform PXE boot with LPVID assigned to vNIC interface - 1Gb ports of HS23 do not handle tagging properly if multichannel mode enabled (pnic ok). Note: ESX driver patch also required. - Port flapping link after FW upgrade and "reboot" when connected to 10Gb PTM module (DAC)
Interoperability Since Previous Release:
- Support for Emulex Virtual Fabric Adapter Advanced (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM System X
Known Issues:
- All 10Gb KX4 ports must be used with 10Gb switches. They will not link at 1Gb. This applies to HS23 LOM and IBM BladeCenter VFA adapters only. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456
Firmware Version: 4.2.412.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- All VFS on Port 1 on optional Card unreachable from outside the host (x3750 M4) - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - 1Gb ports on HS23 LOM not able link up with IBM ICPM (FRU part 44W4486) in BCS chassis - Performance issues with specific DAC cables and SND top of rack switch
Interoperability Since Previous Release:
- UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility
Known Issues:
- All 10Gb ports must be used with 10Gb switches. They will not link at 1Gb. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456 - Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup.
Firmware Version: 4.1.455.6 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Fixed an issue where ASIC randomly hangs losing network connectivity when certain commands are sent from the host. Resulting behavior varies between OS's (Yellow bangs in Windows, PSOD in VMWare) - PHY Loopback fails on 10G ports - UE and hang on LOM or Robalo when powering off Janice in UEFI or PXESelect - Loopback on HS23 now functional in DSAp - DCBX does not converge with firmware on a FCoE fabric - Control C Broken on BE2 - 7 second delay in GET_CARD_ATTRIBUTES command - Emulex VF adapter FCoE link lost on VMware 5.0 - flow control set for 10G Base T phys for autonegotiation - Dynamic link update is not working with NIC UEFI driver - Remove unused definitions in UEFI NIC - Emulex driver expects that the Login Options field be zero - "map r" displays a iSCSI BLK device when no LUNs presented - "X/x Exit without save" does not work as expected - Display proper description as part of EFI Driver Model Related Information - Intermittent "Configuration changed. reset to apply it now?" - Garbled output being displayed at the LUN configuration section. - All Emulex Configuration settings get lost after a reset - Perform additional checks when no Luns are mapped to the target - CHAP name only accepts 6 to 10 characters - Hii ???iSCSI Initiator Configuration??? showing old version screen - iSCSI name is case sensitive - iSCSI HII allows user to select first 8 LUNs as bootable. - iSCSI Boot Enable/Disable option should be port specific - LUN Configuration shows LUN 0, even if no LUNs presented to initiator.
Interoperability Since Previous Release:
- Support for Emulex Virtual Fabric Adapter Advanced (CFFh, 2+2) for IBM BladeCenter
Firmware Version: 4.1.334.47 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- NCSI transmit workaround for IBM - Issues with data reporting when BOFM enabled - Improved network performance throughput - Issues with IBM Management network performance - Logical link status for IBM mezz card shown as 'N/A' - Serial Over LAN fails when more than one blade installed with a single switch - Removed UEFI menu items for unsupported functions on a port - Issues with diagnositics in virtual NIC/UMC mode - Issues with MAC and PHY loopback on OneConnect devices - Several issues with FCoE on some OEM fabric switches
Interoperability Since Previous Release:
- Support for HS23 Virtual Fabric LAN on Motherboard - Support for VFA III (95Y3762, 95Y3768), 90Y6456 - Support for IBM's Features on Demand (FOD) - Formal support for SR-IOV
Firmware Version: 4.0.1062.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- iLab Tucson - lpfc Device Resets and path failures continue after error inject. - Writes do not complete when running LIP test on BE3 port 2 - IPV6 implementations no longer experience an unrecognized routing type error. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - IPV6 implementations no longer experience an unrecognized routing type error. - Installing Windows 2008 or Windows 2008 R2 on remote iSCSI disks no longer causes the system to hang. - Issues no longer occur when resetting a server configured for multipathing on VMware ESX systems. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - An adapter hardware error no longer occurs when running I/O with LUNs on x86 platforms. - Changing from Convergence Enhanced Ethernet (CEE) to Chassis Internal Network (CIN) and then rebooting no longer fails to link-flap (CIN Fabric Login (FLOGI) now occurs). - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - DCB settings can now be configured. - (iSCSISelect) When enabling DHCP for an iSCSI initiator, the Emulex iSCSI Network Configuration utility now waits approximately 20 seconds to make a DHCP connection before returning control. - (FCoE BootBIOS) FCF CEE parameters for Boot from SAN configuration are now saved properly.
Interoperability Since Previous Release:
- Added support for switch-independent multichannel mode. - Added support for IBM Virtual Fabric 10Gb RackSwitch firmware 6.8.1.0. - Added support for IBM Virtual Fabric 10G Switch Module firmware 6.8.1.0. - Added support for Fibre Channel over Ethernet (FCoE) on rack systems. - Added support for iSCSI hardware offload on rack systems. - Added support for Cisco Nexus 5000-series switches.
uEFI Flash Update Version 1.50 (BuildID AHE140YUS) Change History
Version 1.50 - BuildID: AHE140YUS ------------------------------------------------- Problem(s) Fixed: - Fixed the system boot failure due to low PCI memory-mapped resource for a VGA device - Incorporated Intel Microcode Update (MCU) MED 306E4_00000427 to address Intel Erratum Enhancements: - Update Broadcom NIC driver to package ver 16.4.4.5 - Enhanced memory SPD logging for Intel E5-2600 v2 processors - Enhanced error logging for memory-mirroring mode configurations - Support Memory Reference Code Release version 2.0.0.3 - Support AES enable/disable by ASU - Enhanced IBM boot manager - Enhanced TPM Physical Presence lock algorithm Limitations: - When flashing UEFI from version 1.30 or later down to version 1.2x or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30. Dependencies: - The IMM firmware must be at BUILDID: 1AOO58K Version: 4.15 (ibm_fw_imm2_1aoo58k-4.15_anyos_noarch) or higher prior to installing UEFI version 1.50. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release. - The Boradcom Firmware must be at brcm_fw_nic_2.3.1f prior to installing UEFI version 1.50. If the Broadcom firmware level is lower than 2.3.1f, AMM remote console would become Analog mode when IBM logo shows up.
Version 1.40 - BuildID: AHE136AUS ------------------------------------------------- Problem(s) Fixed: - Limited PXE support to four devices Enhancements: - Added support for TKLM Limitations: - When flashing UEFI from version 1.30 or later down to version 1.2x or lower, a "Boot Configuration Error" message will be logged into the UEFI error log. This error does has no impact on the system configuration or operation. No errors are logged when flashing from an earlier version to version 1.30. Dependencies: - The IMM firmware must be at BUILDID: 1AOO40e Version: 2.00 (ibm_fw_imm2_1aoo40e-2.00_anyos_noarch) or higher prior to installing UEFI version 1.30. If the IMM level is lower, the UEFI update module will be rejected as invalid because of additional security features features implemented in this release.
Version 1.31 - BuildID: AHE128GUS ------------------------------------------------- Problem(s) Fixed: - Port 2 of the Broadcom LOM does not perform correctly on Windows 2003 - DMI2 shows up yellow bang mark in device manager on Windows 2003. - Fix Unable get into pDSA GUI_CMD mode on uEFI 27F - IB Card show "Standby Power Enable/Disbale item" in uEFI setup menu - No setup item of Emulex VFA III to enable/disable Adapter Option ROM - Fix Disbale onboard 10G Mezz card malfunction - OS will hang when trigger memory single-bit error in Mirror and Independent Mode - System can not connect to iSCSI server successfully. - GHES Error mesg was found under RHEL6.3 with uEFI 27g - Fixed Unable to pxe boot legacy on slot 1 with vfa 3 - Slot 6 item is missing in "Option ROM Execution Order" - 4R DIMM would run 1.5V on 2DPC or more issue - UEFI setting on F1 menu doesn't sync with ASU setting when boot mode=legacy only - Some USB devices hang at legacy mode (UA-101 audio device) - Platform controlled type msr with wrong value - Can Not enter F1 setup menu after POST failure occur. - OEM SPD Core update. - The DIMMs of CPU2 become not configured after system reboot. - System hang on UEFI logo when any 2 MegaRAID controllers installed. - System hang on recalibrating system power unexpectedly.
Enhancements: - Update the i350 EFI LAN driver from E4618x3_FOD.efi to E5014x3_fod.efi - Multiple PCIe adapter BARs - Configurable MMIO base - Support Firmware first feature - Add informational messages when existing UEFI F1 setup menu - Update the i350 EFI LAN driver from E5014X3_FOD.EFI to E5209X3_FOD.EFI - Rollback the Intel i350 LAN EFI driver to E4618X3_FOD.EFI - Change MM Config Base setting cause SUT hang occasionally. - Add Enable/Disable PCI Device function.
Limitations: Dependencies:
Version 1.30 - BuildID: AHE128BUS ------------------------------------------------- Problem(s) Fixed:
Enhancements: 1. Configurable MMIO base 2. Support Firmware first feature 3. Add informational messages when existing UEFI F1 setup menu 4. Add OEM SPD function Limitations: Dependencies:
Version 1.21 - BuildID: AHE124BUS ------------------------------------------------- Problem(s) Fixed: Enhancements: 1. Improve the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures. Limitations: Dependencies:
Version 1.20 - BuildID: AHE124AUS ------------------------------------------------- Problem(s) Fixed: 1. TPM 1.2 UEFI Preboot Interface Test failed 2. Fix some pcie adapters without build-in oprom cause system hang 3. Update Broadcom driver from package v15.0.3.2 to v15.4.3.1 4. Remove the lower left corner string "System initializing" on screen during POS 5. BOFM Cfg error not reset 6. ibm_fw_uefi_ahe123b-1.20_anyos_32-64.txt lost some OS informations. 7. Set TPM default value to enable 8. Update Broadcom driver from package v15.4.3.1 to v15.4.4.1
Enhancements: Limitations: Dependencies:
Version 1.11 - BuildID: AHE116CUS ------------------------------------------------- Problem(s) Fixed: 1. TPM 1.2 UEFI Preboot Interface Test failed
Enhancements: Limitations: Dependencies:
Version 1.10 - BuildID: AHE116AUS ------------------------------------------------- Problem(s) Fixed: 1. AMM can not delete Windows Boot Manager in Boot Order 2. ME patch for fixing dynamic block erase size and system with SW 3. The boot option is duplicated in "Platform specific boot device" page 4. Wrong information in SMBIOS type 2 5. Remove KVM button function 6. Fix String missing of both primary build ID and IMM info in SMBIOS 7. Fix Boot options of F12 are duplicated at some chassis 8. Fix System will show Boot Configuration Error
Enhancements: 1. Open Optimized Boot setup item with default enable Limitations: Dependencies:
Converged Network Adapter STOR Miniport Driver for Windows Release Notes October 09, 2013
QLogic Corporation All rights reserved
Table of Contents
1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. History 6. Additional Information 7. Firmware Details 8. Trademarks 9. Notices 10. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and release details that apply to the QLogic Converged Network Adapter miniport driver, version 9.1.11.12.
The Converged Network Adapter is supported with the following Microsoft Windows platforms:
* Windows Server 2008 * Windows Server 2008 Core * Windows Server 2008 SP2 * Windows Server 2008 SP2 Core * Windows Server 2008 R2 * Windows Server 2008 R2 Core * Windows Server 2012 * Windows Server 2012 R2
2. Changes
The following changes have been made to the Converged Network Adapter STOR miniport driver.
* Let NIC driver perform reset if NIC driver is present
3. Bug Fixes
The following fixes have been made to the Converged Network Adapter STOR miniport driver.
* ER89373 - FCoE driver stuck in DPC for too long causing assertion during peghalt testing * ER86864 - Updating Qlogic Firmware gives Read only Filesystem Error
4. Known Issues
None.
5. History
5.1 Version 9.1.9.38 - 01/04/12 ------------------
* Addressed issue related to peg halt tests.
5.2 Version 9.1.9.37 - 10/16/11 ------------------
* ER85860 - System unresponsive after FW hang * API version 1.28.0.90 (QLSDM)
5.3 Version 9.1.9.36 - 09/28/11 ------------------
* Log halt events and event 800267xy for ipe * Default to disable minidump * Improved sem5 polling for reset * ER83352 - QCC CLI hung after making personality change on QLE8242 * Cleaned up accumulated io completion properly when link down occurs * ER82074 - CNA 81xx can not load the driver after hot plug in OEM system * ER84718 - Assertion failures and system hang when peg halt is done in loop with NIC and FCoE driver running. * API version 1.28.0.90 (QLSDM)
5.4 Version 9.1.9.19 - 05/11/11 ------------------
* Added support and retry logic code to track down io failure during link down.
5.5 Version 9.1.9.18 - 03/01/11 ------------------
* Made compatible with OEM DSM that handles only path failure by deferring io error when link/port down timeout exceeds.
5.6 Version 9.1.9.17 - 02/14/11 ------------------
* Added new cold reset when loaded before nic driver during IBFT. * Synchronized vp's rscn handling with vp 0.
5.7 Version 9.1.9.16 - 02/01/11 ------------------
* ER78315 - Target discovery not completed within port down timeout would cause driver to logout the first discovered target. * ER78316 - Target discovery was initiated prior to firmware ready. * ER78827 - The firmware version in QCC is not updated correctly after flashing using NIC interface. * API version 1.28.0.83 (QLSDM) * Firmware v5.04.04
5.8 Version 9.1.9.15 - 10/01/10 ------------------
* Added support for the 82xx family of Converged Network Adapters * API version 1.28.0.80 (QLSDM) * Firmware v5.04.01
5.9 Version 9.1.8.27 - 05/18/10 ------------------
* ER71241 - Degraded write performance with large file and Windows Server 2008 R2 file system * API version 1.28.0.73 (QLSDM) * Firmware v5.03.02
5.10 Version 9.1.8.26 - 03/18/10 ------------------
* Added LR Converged Network Adapter Adapter support (QLE81xx) * Updated embedded firmware to v5.3.2 (QLE8042) * Addressed virtual link down issue reported by HDS (ER68836) * API version 1.28.0.73 (QLSDM) * Firmware v5.03.02
5.11 Version 9.1.8.19 - 12/11/09 ------------------
* System freezes after active BNT CEE switch is rebooted * Adapter management utility fails to delete Virtual ports * API version 1.28.0.73 (QLSDM) * Firmware v5.02.01
5.12 Version 9.1.8.17 - 05/21/09 ------------------
* API version 1.28.0.73 (QLSDM) * Firmware v5.01.03
6. Additional Information
None.
7. Firmware Information
Firmware is resident on the adapter, for Converged Network Adapters.
8. Trademarks
Accelera, Accelerating Cluster Performance, FastFabric, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, Intelligent NIC, Networking University, NetXen, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. To the extent a name or logo does not appear on this list does not constitute a waiver of any and all intellectual property rights that QLogic Corporation or its subsidiaries has established in any of its product, feature, or service names or logos. All other brand and product names are trademarks or registered trademarks of their respective owners.
9. Notices
Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
10. Contacting Support
Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods:
(c) Copyright 2012. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. qlgc_dd_fc_cna-9_1_11_12_windows_32-64_chg
Matrox G200eR (Renesas) Display Only Driver for Windows Server 2012
Rev. 4.00.01.004 - Certified with WHCK Build (8400)
KNOWN ISSUES ------------ - None
HISTORY ------- Rev. 4.00.01.003 - Beta version mtrox_dd_video_4_00_01_004_winsrvr_64_chg
Broadcom Firmware Update Utility for IBM servers and options using the Broadcom NetXtreme and NetXtreme II ethernet adapter.
Version 2.3.1e, March 06, 2014
This package updates the Broadcom firmware for the following items:
Package Version 2.3.1e ====================== There is no fw level change between 2.3.1d and 2.3.1e. 2.3.1e build has been created just to fix a firmware update tool applicaton extention file issue.
Package Version 2.3.1d ====================== UEFI code has been changed for 00D9700. This is the only change between 2.3.1c and 2.3.1d.
package version 2.3.1c ====================== Changes have been applied to only NX2 devices. Please refer to table above for each firmware code change. First firmware update tool is for 578xx series.(88Y5921, 94Y5230, 94Y5232, 94Y5181, 44T1361)
package version 2.2.1b ====================== -Changes were made to 44W4475,44W4479 devices to pick new level of UEFI v7.6.52. This UEFI code change for 5709/5709s devices is the only change betweeen 2.2.1b and 2.2.1a.
package version 2.2.1a ====================== -Changes were made to the 42C1781, 90Y9370, 90Y9352, 39Y6066, 49Y4220, 49Y7910, 49Y7900. (See above list for the firmware levels in your Broadcom Device.)
package version 2.1.9a ============================================================================================ -Changes made to the 5718, 5719 and 5720 firmware levels. (90Y9352, 90Y9370, 49Y7900. See above list for current firmware levels.) -No change for NX2 products in this package.
package version 2.1.8e ====================== Problems Fixed: - Changes were made to the UEFI code to fix 49Y7910(BCM57712/Cobia) issues.
package version 2.1.8d (See brcm_fw_nic_2.1.8d-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 46M6164, 46M6168, 49Y7910 and 81Y3133. - Changes were mande to the PXE code for the 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168, 49Y4220, 49Y7910 and 81Y3133. - Changes were made to the UEFI code for the 42C1780, 42C1781, 42C1790, 42C1791, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168, 49Y4220, 49Y7910 and 81Y3133. - Changes were made to the iSCSI code for the 42C1780, 42C1781, 49Y4220 and 49Y7910.
package version 2.1.7e (See brcm_fw_nic_2.1.7e-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the UEFI code for the 42C1780, 42C1781, 44W4475 , 44W4479 , 44X1940
and 49Y4220. - Added support for the 49Y7910.
package version 2.1.7d (See brcm_fw_nic_2.1.7d-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the UEFI code for the 42C1780, 42C1781, 42C1790, 42C1791, 44W4465 , 44W4466 , 44W4475 , 44W4479 , 44X1940 , 46M6164 , 46M6168, 49Y4220 and 81Y3133. - Fixed a problem where the MAC addresses for the HS22/HS22V LOM were incorrectly set to zero.
package version 2.1.7c (See brcm_fw_nic_2.1.7c-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 46M6164 and 46M6168. - Changes were made to the NCSI code for the 46M6164 and 46M6168. - Changes were made to the PXE code for the 42C1790, 42C1791, 46M6164, 46M6168, 44W4465 and 44W4466. - Changes were made to the UEFI code for the 42C1790, 42C1791, 46M6164, 46M6168, 44W4465 and 44W4466. - Changes were made to the iSCSI code for the 42C1780, 42C1781 and 49Y4220.
package version 2.1.7b (See brcm_fw_nic_2.1.7b-chg_anyos_anycpu.zip for details.) Problems Fixed: - Fixed problem running the PPC firmware update tool on some PPC systems.
package version 2.1.7a (See brcm_fw_nic_2.1.7a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1909, 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4195, 4198, 4199, 4254, 4255, 7141, 7144, 7145, 7146, 7148, 7149, 7164, 7233, 7234, 7378, 7379, 7380, 7809, 7836, 7837, 7839, 7870, 7871, 7901, 7902, 7944, 7945, 7946, 7947, 42C1780, 42C1781, 42C1790, 42C1791, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168 and 49Y4220 - Changes were made to the NCSI code for the 1909, 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4195, 4198, 4199, 4254, 4255, 7145, 7146, 7148, 7149, 7164, 7378, 7379, 7380, 7809, 7836, 7837, 7839, 7870, 7871, 7872, 7944, 7945, 7946, 7947, 44W4475, 44W4479, 46M6164 and 46M6168. - Changes were made to the iSCSI code for the 42C1780, 42C1781 and 49Y4220. - Changes were made to the UEFI code for the 46M6164, 46M6168, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 42C1780, 42C1781, 42C1790, 42C1791 and 49Y4220. - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168 and 49Y4220.
package version 2.1.6b (See brcm_fw_nic_2.1.6b-chg_anyos_anycpu.zip for details.) Problems Fixed: - The update tool was modified to fix a problem updating the firmware when certain option cards are installed in the system.
package version 2.1.6a (See brcm_fw_nic_2.1.6a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1909, 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4195, 4198, 4199, 4254, 4255, 7141, 7144, 7145, 7146, 7148, 7149, 7164, 7233, 7234, 7378, 7379, 7380, 7809, 7836, 7837, 7839, 7870, 7871, 7901, 7902, 7944, 7945, 7946, 7947, 42C1780, 42C1781, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168 and 49Y4220 - Changes were made to the NCSI code for the 46M6164, 46M6168, 44W4465, 44W4466, 42C1790, and 42C1791. - Changes were made to the iSCSI code for the 42C1780, 42C1781 and 49Y4220. - Changes were made to the UEFI code for the 46M6164, 46M6168, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 42C1780, 42C1781, 42C1790, 42C1791 and 49Y4220. - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164, 46M6168 and 49Y4220.
package version 2.1.5b (See brcm_fw_nic_2.1.5b-chg_anyos_anycpu.zip for details.) Problems Fixed: - Added iSCSI config update support for mfg.
package version 2.1.5a (See brcm_fw_nic_2.1.5a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the NCSI code for the 1909, 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4195, 4198, 4199, 4254, 4255, 7145, 7146, 7148, 7149, 7164, 7378, 7379, 7380, 7809, 7836, 7837, 7839, 7870, 7871, 7872, 7944, 7945, 7946, 7947, 44W4475, 44W4479, 42C1790 and 42C1791 - Changes were made to the UEFI code for the 46M6164, 46M6168, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 42C1780, 42C1781, 42C1790, 42C1791 and 49Y4220. - Changes were made to the IPMI code for the 7141, 7144, 7233, 7234, 7901 and 7902.
package version 2.1.4a (See brcm_fw_nic_2.1.4a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164 and 46M6168. - Changes were made to the UEFI code for the 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164 and 46M6168.
package version 2.1.3c (See brcm_fw_nic_2.1.3c-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the iSCSI code for the 42C1780 and 42C1781. - Changes were made to the UEFI code for the 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 46M6164 and 46M6168. - Changes were made to the boot code for the 46M6164 and 46M6168.
Enhancements: - Added version check to prevent firmware updates of code that is not newer than already installed code. - Added "-force" command line option to allow forcing the firmware update.
package version 2.1.3b (See brcm_fw_nic_2.1.3b-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 4254, 4255, 7141, 7144, 7145, 7146, 7233, 7234, 7378, 7379, 7380, 7836, 7837, 7839, 7870, 7871, 7901, 7902, 7944, 7945, 7946, 7947, 42C1780, 42C1781, 44W4475, 44W4479 and 44X1940. - Changes were made to the NCSI code for the 1936, 1949, 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 4254, 4255, 7145, 7146, 7378, 7379, 7380, 7836, 7837, 7839, 7870, 7871, 7944, 7945, 7946, 7947, 44W4475 and 44W4479. - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781, 44W4475, 44W4479 and 44X1940. - Changes were made to the UEFI code for the 42C1780, 42C1781, 44W4475, 44W4479 and 44X1940. - Changes were made to the iSCSI code for the 42C1780 and 42C1781.
package version 2.1.3a (See brcm_fw_nic_2.1.3a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the PXE code for the 26K4842, 39R8624, 39Y9306, 39Y9310, 42C1600, 42C1632, 46M6164, 46M6168, 44W4465, 44W4466, 73P9030, 22P7801, 31P6301, 31P6401, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 42C1790, 42C1791, 73P3501, 73P4001, 73P4101 and 73P4201. - Changes were made to the UEFI code for the 46M6164, 46M6168, 44W4465, 44W4466, 42C1790, and 42C1791. - Changes were made to the NCSI code for the 46M6164, 46M6168, 44W4465, 44W4466, 42C1790, and 42C1791. - Changes were made to the boot code for the 46M6164, 46M6168, 44W4465, 44W4466, 42C1790, and 42C1791.
package version 2.1.1c (See brcm_fw_nic_2.1.1c-chg_anyos_anycpu.zip for details.) Problems Fixed: - none.
Enhancements: - Added support for the 1949, 4254, 4255, 7378, 7379, 7380, 7871, 7944 and 7945.
package version 2.1.1b (See brcm_fw_nic_2.1.1b-chg_anyos_anycpu.zip for details.) Problems Fixed: - Fixed problem where the firmware update failed to run correctly on RHEL5u4-XEN.
package version 2.1.1a (See brcm_fw_nic_2.1.1a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1885, 1913, 1914, 1915, 1936, 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 7141, 7144, 7163, 7233, 7234, 7809, 7836, 7837, 7839, 7870, 7901, 7902, 7946, 7947, 7978, 7979, 7995, 7996, 7997, 8853, 8877, 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 39Y6066, 42C1780, 42C1781, 42C1790 and 42C1791. - Changes were made to the NCSI code for the 1936, 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 7809, 7836, 7837, 7839, 7870, 7946, 7947, 44W4465, 44W4466, 44W4475, 44W4479, 42C1790 and 42C1791. - Changes were made to the PXE code for the 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 39Y6066, 42C1780, 42C1781, 42C1790 and 42C1791. - Changes were made to the UEFI code for the 44W4465, 44W4466, 44W4475, 44W4479, 44X1940, 42C1780, 42C1781, 42C1790 and 42C1791. - Changes were made to the iSCSI code for the 42C1780 and 42C1781.
Enhancements: - Added support for the 46M6164 and 46M6168.
package version 2.1.0a (See brcm_fw_nic_2.1.0a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1936, 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 7141, 7144, 7233, 7234, 7836, 7837, 7839, 7870, 7901, 7902, 7946, 7947, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479 and 44X1940. - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466, 44W4475, 44W4479 and 44X1940. - Changes were made to the ISCSI code for the 42C1780 and 42C1781.
package version 2.0.9h (See brcm_fw_nic_2.0.9h-chg_anyos_anycpu.zip for details.) Problems Fixed: - Removed the minimum boot code level check for the 44W4465 and 44W4466.
Enhancements: - Added support for the 3808, 3809, 3815, 3817, 3821, 3822, 4198, 4199, 7836, 7837, 7839 and 9233.
package version 2.0.9g (See brcm_fw_nic_2.0.9g-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the UEFI code for 42C1780, 42C1781, 42C1790, 42C1791, 44W4465 44W4466, 44W4475, 44W4479 and 44X1940. - Fixed the problem where the PXE code for the 44W4465 and 44W4466 failed to update under 64bit Linux.
Enhancements: - Added support for the 7946 and 7947.
package version 2.0.9f (See brcm_fw_nic_2.0.9f-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1885, 1913, 1914, 1915, 7141, 7144, 7233, 7234,
7940, 7941, 7971, 7972, 7978, 7979, 7985, 7995, 7996, 7997, 8853, 8877, 39Y6066, 42C1780, 42C1781, 42C1790, 42C1791, 44W4465, 44W4466 and 44W4479. - Changes were made to the NCSI code for the 42C1790, 42C1791, 44W4465, 44W4466 and 44W4479. - Changes were made to the PXE code for 42C1790, 42C1791, 44W4465, 44W4466 and 44W4479.
Enhancements: - Added support for the 1936, 7870 and 44W4475. - Added UEFI code for 42C1790, 42C1791, 44W4465, 44W4466, 44W4479 and 44X1940.
package version 2.0.9e (See brcm_fw_nic_2.0.9e-chg_anyos_anycpu.zip for details.) Problems Fixed: - Added a bnx2 device driver version check for version 1.6.6b or greater.
package version 2.0.9c (See brcm_fw_nic_2.0.9c-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1885, 1915, 7901, 7902, 7971, 7972, 7995, 8853 and 44W4479. - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781 and 44W4479. - Changes were made to the iSCSI code for the 42C1780 and 42C1781 - Changes were made to the NCSI code for the 44W4479.
Enhancements: - Added support for the 44X1940.
package version 2.0.8f (See brcm_fw_nic_2.0.8f-chg_anyos_anycpu.zip for details.) Problems Fixed: - Fcode support was removed for the PXE code for the 44W4465 and 44W4466. This change does not result in a change in the PXE code version number. - Changes were made to the PXE code for the 39Y6066, 42C1780 and 42C1781 to fix a problem where some systems hang when loading PXE code.
package version 2.0.8e (See brcm_fw_nic_2.0.8e-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the PXE code for the 39Y6066, 42C1780, 42C1781 and 44W4479. - Changes were made to the IPMI code for the 7141, 7144, 7233 and 7234. - Changes were made to the UMP code for the 7901 and 7902.
Enhancements: - Added support for the 6388, 7942, 44W4465 and 44W4466.
package version 2.0.8d (See brcm_fw_nic_2.0.8d-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 7141, 7144, 7233 and 7234.
Enhancements: - Added support for the 42C1780 and 42C1781.
package version 2.0.8c (See brcm_fw_nic_2.0.8c-chg_anyos_anycpu.zip for details.) Problems Fixed: - None.
Enhancements: - Added support for the 7901 and 7902
package version 2.0.8b (See brcm_fw_nic_2.0.8b-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the PXE code for the 39Y6066.
Enhancements: - Added support for the 44W4479.
package version 2.0.8a (See brcm_fw_nic_2.0.8a-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1885, 1913, 1914, 1915, 7141, 7144, 7971, 7972, 7978, 7979, 7985, 7995, 7996, 7997, 8853, 8877, 9228, 9229, 9230 and 39Y6066. - Changes were made to the ASF code for the 6218, 6223, 6225, 6227, 6228, 8488, 8648, 9228, 9229, 9230. - Changes were made to the UMP code for the 39Y6066. - Changes were made to the PXE code for the 22P7801, 26K4842, 31P6301, 31P6401, 39R8624, 39Y6066, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 39Y9306, 39Y9310, 42C1600, 42C1632, 73P3501, 73P4001, 73P4101, 73P4201, 73P9030. - Changes were made to the IPMI code for the 1916, 8014 and 8028.
Enhancements: - Added support for the 7233, 7234, 7940 and 7941.
package version 2.0.7 (See brcm_fw_nic_2.0.7-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the PXE code for the 22P7801, 26K4842, 31P6301, 31P6401, 39R8624, 39Y6066, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 39Y9306, 39Y9310, 42C1600, 42C1632, 73P3501, 73P4001, 73P4101, 73P4201, 73P9030.
Enhancements: - Added support for the 1916, 8014 and 8028.
package version 2.0.6 (See brcm_fw_nic_2.0.6-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1913, 1914, 7141, 7143, 7144, 7978, 7979, 7996, 7997, 8877 and 39Y6066. - Changes were made to the UMP code for the 39Y6066. - Changes were made to the PXE code for the 39Y6066.
package version 2.0.5 (See brcm_fw_nic_2.0.5-chg_anyos_anycpu.zip for details.) Problems Fixed: - None
Enhancements: - Added support for the 4190, 4191, 4192, 4193, 4194, 4367 and 4368.
package version 2.0.4 (See brcm_fw_nic_2.0.4-chg_anyos_anycpu.zip for details.) Problems Fixed: - None
Enhancements: - Added support for the 7141, 7143 and 7144.
package version 2.0.3 (See brcm_fw_nic_2.0.3-lin-win-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1885, 1913, 1914, 1915, 7971, 7972, 7978, 7979, 7985, 7995, 8853, 8877, 39Y6066. - Changes were made to the IPMI code for the 1879, 1880, 1883, 1884, 1887, 4362, 4363, 4364, 4365, 4366, 7362, 7364, 7365, 7367, 7973, 7974, 7975, 7976, 7977, 7981, 7984, 7986, 8485, 8490, 8491, 8832, 8835, 8837, 8840, 8841, 8843, 8848, 8849, 8850, 8863, 8864, 8865, 8866, 8872, 8874, 8878, 8879. - Changes were made to the ASF code for the 6218, 6223, 6225, 6227, 6228, 8488, 8648, 9228, 9229, 9230. - Changes were made to the PXE code for the 22P7801, 26K4842, 31P6301, 31P6401, 39R8624, 39Y6066, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 39Y9306, 39Y9310, 42C1600, 42C1632, 73P3501, 73P4001, 73P4101, 73P4201, 73P9030.
package version 2.0.0b (See brcm_fw_nic_2.0.0b-nx-nx2-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changed the firmware update process to NOT reset the ethernet devices during the firmware update process.
package version 2.0.0 (See brcm_fw_nic_2.0.0-nx-nx2-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the UMP (Universal Management Port) code for the 1885, 7971, 7972, 7995 and 8853.
package version 1.1.1 (See brcm_fw_nic_1.1.1-nx-nx2-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 1879, 1880, 1887, 4347, 4348, 4362, 4363, 4364, 4365, 4366, 6218, 6223, 6225, 6227, 6228, 7969, 7973, 7974, 7975, 7976, 7977, 7992, 8485, 8486, 8488, 8490, 8491, 8648, 8837, 8840, 8841, 8849, 39Y6098, 39Y9306, 42C1600, 42C1632 and 73P3501. - Changes were made to the IPMI code for the 1879, 1880, 1887, 4362, 4363, 4364, 4365, 4366, 7969, 7973, 7974, 7975, 7976, 7977, 7992, 8485, 8490, 8491, 8837, 8840, 8841 and 8849. - Changes were made to the PXE code for the 22P7801, 26K4842, 31P6301, 31P6401, 39R8624, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 39Y9306, 39Y9310, 42C1600, 42C1632, 73P3501, 73P4001, 73P4101, 73P4201 and 73P9030.
package version 1.1.0 (See brcm_fw_nic_1.1.0-nx-nx2-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the Boot Code for the 1913, 1914, 4347, 6218, 6223, 6225, 6227, 6228, 7969, 7971, 7972, 7978, 7979, 7985, 7995, 8486, 8648, 8853, 8877, 9228 and 9229. - Changes were made to the ASF code for 6218, 6223, 6225, 6227, 6228, 8648, 9228 and 9229. - Changes were made to the PXE code for the 39Y6066. - Changes were made to the
Enhancements: - Added support for the 1879, 1880, 1883, 1884, 1887, 1913, 22P7801, 31P6301, 31P6401, 39Y9306, 39Y6066, 39Y6079, 39Y6088, 39Y6093, 39Y6098, 39Y9310, 4348, 4366, 7362, 7364, 7365, 73P3501, 73P4001, 73P4101, 73P4201, 7992, 7995, 8488 and 9230.
package version 1.0.0 (See brcm_fw_nic_1.0.0-nx-nx2-chg_anyos_anycpu.zip for details.) Problems Fixed: - Changes were made to the boot code for the 8832, 1914, 7971, 7972, 7978, 7979 7985, 8853 and 8877. - Changes were made to the UMP (Universal Management Port) code for the 7971, 7972 and 8853. brcm_fw_nic_2_3_1f_windows_32-64_chg
=============================================================================== Emulex NIC Device Driver for Windows ===============================================================================
Driver version: 4.6.203.1 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - HyperV VM's tagged VLAN's did not get an IP Address - NIC Function Properties > Status for PCI Express Link Speed says Invalid Link Speed detected. - iSCSI ports of CNA card in ESXi 4.1u3 OCM GUI (vCenter plug in) is not getting displayed
Driver Vers: 4.4.176.2 (Previously supported on IBM Flex) Driver Vers: 4.2.390.6 (Previous Release for IBM Rack & BladeCenter)
Problems Fixed: - Cleaned up inf file - TOE Offload Fails when the same neighbor is added more than once
Incremental Interoperability: - Windows 2012
Known Issues: - Switch Independent Mode not supported in a HyperV environment - Default values vary between inbox and out of box drivers. For example: Configuration section - Wake On LAN - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ Performance section - Maximum Number of RSS Queues - Inbox default is ‘4’ - out-of-box default is ‘8’ - Virtual Machine Queues - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ You may select the button to reset all driver settings to defaults after any installation.
Driver Vers: 4.1.370.0 (Previously supported on IBM SystemX, BladeCenter & Flex)
Incremental Interoperability: - Initial release for IBM Flex
Problems Fixed:
- HS23 - Sleep Stress test failed with bugcheck C4 during driver verify - TOE with RSC enabled causes Network to go down - Augmented WOL Capabilities - Driver parameter query failures - BSOD 9F during shutdown if device stops responding - RSS queues may change port during MPRestart and MPPause
Driver Vers: 4.1.334.25 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Emulex: Large Receive Offload support needed in Windows NIC driver - Win WoL: Need to report WoL based on ARM reported capabilities - update the driver strings for existing cards - RSS code may access PerMessage beyond end of array - 16 queue RSS for BE3 on Windows 2008 R2 - fix unverified mode of occfg to allow customer workarounds - 16 queue RSS lockup if SRIOV enabled in registry - Standard Property Page for 1 port Windows Azure card - Timeout RQ flush to avoid bugcheck during shutdown - Change receive buffer alignment to use Windows 2008 R2 TCPIP fast path - Emulex: BSOD - Replacing BE3 card with a BE2 card after installation of new kit driver and firmware on Win 2k3 SP2 R2x64 (vNIC enabled IBM machine) - be2nd62.inf failed ChkInf - VMQ registry keys displayed in Windows 2008 - be_function_prepare_nonembedded_ioctl overwrites version field - autoi reboot fails on Win2K8 x64 when verifier enabled - PCI ID: Updates for Endeavor 2 for IBM- PCI IDs Rev 1.22 - Emulex NIC driver causes BSoD during shutdown whenever disable firewall or join domain network - Sleep Stress test failed with bugcheck C4 during driver verify - Disable TOE by default for IBM - BSOD 9F during shutdown if device stops responding
Driver Vers: 4.0.317.0 (Previously supported on IBM SystemX & BladeCenter) elx_dd_nic_ibm1212-4_6_203_1-6_windows_32-64_chg
=============================================================================== Emulex iSCSI Device Driver for Windows ===============================================================================
Driver version: 4.6.130.0 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - Cleaned up PCI ids in the inf file
Driver Vers: 4.1.334.0 (Previously supported on IBM SystemX, BladeCenter & Flex)
Incremental Interoperability: - Initial release for IBM Flex
Problems Fixed:
- Logout handling on boot session when multiple sessions exists to the same boot target - Add PCI ID as per Rev 1.18 for Windows iSCSI Driver - Multipath IO fails producing a BSOD - Persistent login to Max targets + 1 from WMI causes a hang - Update Nomad Device Name as per 1.19 for Windows iSCSI drivers - PCI ID: Updates for Endeavor 2 - PCI IDs Rev 1.22
Driver Vers: 4.0.317.0 (Previously supported on IBM SystemX & BladeCenter) elx_dd_iscsi_ibm1212-4_6_279_0-1_windows_32-64_chg
=============================================================================== Emulex FC Device Driver for Windows ===============================================================================
Driver version: 2.74.016.001 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - Cleaned up a variety of corner case issues to avoid BSODs - Fixed IOCTL encounter bug-chk on BE3 during NPIV tests - Fixed reporting incorrect error code when creating vport on a switch without NPIV supported - Updated the default model name for 16G HBAs
Driver version: 2.74.009.001 (Previously supported on IBM SystemX, BladeCenter & Flex)
Problems Fixed: - Clean up non-critical legacy FC and uCNA incompatibilities - LUN masking doesn't persist after reboot - Emulex GUI crashes when closing a running Upgrade utility and re-open it in 802.3 configuration with IP or MAC - Several bugs related to creation or deletion of vports
Incremental Interoperability: - Windows 2012 - Improved debug capabilities - Tighter integration with MS Windows Design Kit
Driver version 2.70.018 (Previously supported on IBM SystemX, BladeCenter & Flex)
Problems Fixed:
- Fixed sending ABTS continuously to Flogi issue - Fixed reset and link bounce issues for SLI4 FC public loop - Added support for ABTS timeout handling for both SLI3 and SLI4 - Fixed loopback test incorrectly dropping the loopback frame in SLI4 - Fixed exchange management issue in SLI4 CT receive path causing array overflow - Fixed firmware version update issue following download in link up state - Fixed problem in init_vfi completion handler that stalled fabric login on BE FCoE FW - Fixed problem that caused OCM ELS Echo Test to fail - Fixed the loopback test issue in recovering from error condition - Add persistent link down support for SLI4 FC - Fix DFC_IssueDumpMBox to manage request type 3 which includes link select option - Modified reinitialization sequence following reset to fix discovery failure post type 1 or type 3 reset - Fixed new firmware dump issue
Firmware Version: 2.01a11 (w/ 5.12a13 Universal Boot Code) (Supported for IBM System x & BladeCenter)
Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM (BOFM) - Emulex FC configuration utility is in the wrong F1 setup screen - IBM CIOv adapter connected to Brocade 8 Gig FC BladeCenter switch intermittently Links up at less than 8 Gig
Firmware Version 2.01a3 (w/ 5.12a5 Universal Boot Code)
New Features
- Enhanced timeout notifications for processing abort failures.
Problems Fixed:
- All multi-abort I/Os are returned on the same ring from which the ABORT_MXRI command was received. - Changed the TRCV response in the abort state to CMD RJT to enable the TRSP to be processed. - Corrected an issue with blocked TSEND operations. - Corrected a buffer leak issue with RRQ exchanges. - Corrected an issue where the TRCV IOCB was de-queued improperly causing a XFR_RDY flood. - Corrected an issue where the OXID field was not loaded in the XRI_ABORTED IOCB. - Corrected an issue in recognizing whether an EEPROM is present.
Dependencies:
- The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly.
1. Fixed an issues booting when more than 8 ports are present in the system and fixed an adapter display issue when more than 8 ports are present in the systems 2. Fixed issues installing and booting O/Ss on ports greater than 8. 3. Fixed some boot time screen display issues.
(2) OpenBoot version 3.10a3
This version of OpenBoot supports FC-AL, Private loop, Public loop, and Fabric Point to Point. Also, it supports multi-initiators and multi-LUNs (0 through 4055)
Problems fixed, features added or other updates:
1. Unrelated to IBM
(3) EFIBoot version 4.12a12
The current EFI (Extensible Firmware Interface) Boot provides 64-bit System boot capability through the use of the EFI Shell. This EFIBoot supports EFI Specification 1.10 and EFI Source Code version 1.10.14.61.
Problems fixed, features added or other updates:
1. Only certain OEM HBAs will locate PlatformToDriverConfiguration- ProtocolGuid. Others just skip and continue processing 2. UEFI2.3 Hii Configuration Utility changes 3. HII Browser Save option does not work
1. On a port connected to a 3PAR "MBOD" cage, the test runs IO to the disk drives and issues a "controlport offline" command to offline the port while IO is running.
2. While doing target side cable pull testing with Block Guard (T10) Enabled we observed that adapter is not sending RSCN to AIX.
Dependencies: - The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly. elx_fw_fc_ibm1212-2_01a11-11_windows_32-64_chg
BIOS/FW/UEFI Update for ServeRAID H1135 Controller for IBM Flex System and BladeCenter (90Y4750)
Controller Supported: ServeRAID H1135 Controller for IBM Flex System and BladeCenter (90Y4750)
BIOS Changes Enhancement(s): - Core BIOS and BIOS configuration utility will display "FF" as the PCI slot number when proper slot information is not available. - Increased the disk drive spin-up timeout value to accommodate disk drives having larger spin up times.
Fix(es): - Fixed an issue where the adapter order does not get written to NVM and "Updating Adapter Order" displays on every reboot. - Fixed issue where zero sized volume was showing "4. 0 GiB." - Fixed issue where devices, which are not attached to adapter 0, could not be promoted to positions in the boot order when they were selected in the configuration utility. - Fixed an issue where IOS Banner(POST) not showing SAS Discovery error when more than one HBA is connected to the host system. - Fixed an issue where the SMART status is not correctly displayed for bare drives. - Fixed an issue in SAS topology where a RAID disk is highlighted and attempted to set as preferred boot device or alternate boot device, the configuration utility displays a SAVE/DISCARD prompt. - Fixed an issue where the firmware was showing a large elapsed time when a format operation crosses midnight in the system clock.
Firmware Changes Enhancement(s): - Added support for 4GB DIMM - Added the ability for user the enable/disable of the drive write cache during the BIOS start up.
Fix(es): - Fixed an issue where a request sense command, which is executed after a SATA drive is in active state is moved to idle power condition state, has no 'Additional Sense' information set. - Fixed an issue where protected information error "Logical block reference tag check failed" is received when an IR volume is deleted. - Fixed an issue Self-Test Results log page where values for update parameter code, format and linking, and parameter length are not recorded. - Fixed an issue sending vital product data inquiry with vital product data page set as invalid (0xFF) while diagnostic is running on a SATA drive results in segmentation fault 0x1901. - Fixed an issue where input/output is sent to SATA drives before the drives are ready. - Fixed an issue where fault 8405 was being hit while disabling and enabling the phy to which secondary drive is connected with IOs active. - Fixed an issue where subsequent commands sent to a SATA drive fail after a write same command failure until NCQ error handling is triggered or the device is reset. - Fixed an issue where Report Luns command sent to SATA drive fails if the drive is spun down. - Fixed an issue where hotspare does not resynch with second raid volume when both volumes are in degraded state. - Fixed an issue where incorrect sense data is populated when Security Protocol IN/OUT command is sent to supported drive. - Fixed an issue where allocation length for inquiry SCSI Command is not handled Properly during SATA Drive Format. - Fixed an issue during SATA drive format where vital product data inquiry command is executed for SATA drive with invalid page code, and the command is passed with no data instead for failing with CC and sense data. - Fixed an issue where the host will not indicate the existence of the expander attached drives if the direct attached device re-ordering feature is enabled. - Fixed an issue where protected information errors are observed on a RAID 1 volume its BGI is not completed, and its member physical disks are removed and inserted. - Fixed an issue where the TM response was set to failed if the device is missing due to the DO NOT SEND TASK IU flag being enabled. - Fixed an issue where DMD (Device Missing Delay) timer is not set to the default time when the total Report Device Missing Delay is greater than 0x7F seconds. - Fixed an issue where RAID1 volume fails to resynch when a new compatible bare drive is available in the primary drive slot. - Fixed an issue where error handling for errors, that cause the DMA engines to halt, are not handled properly and multithreaded IOs can hang if the same control block is used too soon. - Fixed an issue where a third hotspare is created even if the number of hotspares currently present in the RAID Configuration is 2. - Fixed an issue where inactive foreign volume information cannot be seen in SASBIOS when a native volume is deleted.
UEFI Changes Enhancement(s) - Additional information such as vendor id and product id added to the HII Create Configuration Screen. - Added ability to check to detect missing hotspares to HII. - Modified to be obtained PCI Slot Number information from the system firmware protected information. - Additional character "M" will be displayed as part of the device display identifier of a multipathed disk. - Ability in HII to detect missing hotspares and provide a facility to delete the missing hotspares. - Implemented Configuration Summary and Simple Virtual Disk Creation Support for Unified Configuration Management. - Modified UEFI driver to wait for a maximum of 10 seconds for the controller to become ready, so controller gets discovered in the OS.
Fix(es): - Fixed an issue where Enable/Disable write cache does not work for SAS drives. - Fixed an issue where HII Configuration utility does not allow the user to create a RAID0 with single disk present in the topology. - Fixed an issue in Create Configuration menu where additional drive information is not getting updated appropriately in HELP area. - Modified to prevent Write Cache settings options from appearing for the IR firmware. - Fixed an issue where SATA volume members and hotspare drives are labeled as 'M' in a multipathed environment. - Fixed an issue to prevent HII from allowing the option to enable/disable write cache for SATA drives. - Fixed an issue where multipathing is disabled in Manufacturing page settings, but volume members and hotspare drives are labeled as "M." - UEFI driver modified to check BIOS Options in order to determine if is should manage the controller.
Multiboot Image for QLogic Fibre Channel Expansion Cards for IBM BladeCenter Release Notes Version f7.01.00-b2.14-e2.51 10/19/13 ===============================================================================
A. BIOS Release Notes B. EFI Release Notes C. FCODE Release Notes D. No Release Notes for Firmware
=============================================================================== A. QLogic BIOS Release Notes
QLogic Corporation. All rights reserved.
Table of Contents
1. Change History 2. Known Issues 3. Notices 4. Contacting Support
1. Change History
These release notes describe the changes, fixes, known issues, and release details that apply to the BIOS for FC/FCoE Adapters.
This section contains:
* 1.1 Version * 1.2 Changes * 1.3 Bug Fixes
1.1 Version
Version 2.14 * Removed Beta banner
Version 2.14 Beta 3 * Added check invalid LUN when configuring boot target (ER105664).
Version 2.14 Beta 2 * Added support for P3P * Removed Execution Throttle Option From CTRL_Q
Version 2.14 Beta 1 * Fix bug that cause external looback to fail (er71773). Added support for Hilda
Version 2.13 * Fixed bug in EDC update code.
Version 2.12 * Added code code to check for non-EDC HBA's in CTRL-Q utility.
Version 2.11 * Added code to use Echo Test instead of Loopback for F_PORT connection. Added code to update EDC. Removed support for CLP strings. Added check for SSDID = 176h for EDC.
Version 2.10 * Changed Link-up timer to 30 seconds.
Version 2.09 * Added code to update MAC address if PXE BOFM MAC address configured. Fixed bug in setting buffer pointer.
Version 2.08 * Changed code to not Disable BIOS when no BOFM drives configured.
Version 2.07 * Added code to save a backup copy of NVRAM data and use it if primary is corrupted.
Version 2.06 * Fixed bug in restoring MAC Address.
Version 2.05 * Added support for ISP8001.
Version 2.04 * Fixed comestic bug is CTRL-Q utility in displaying selectable boot lun. Changed code to correctly display boot device type. Removed 8G support for QMI2572 Added support for UEFI environment.
Version 2.03 * Changed code to return good status when 'FC' section not found in BOFM. Removed check for 'Comsumed' flag when setting BOFM targets. Fixed issue with KVM.
Version 2.02 * Added code to setup EDI for alternate adapter.
Version 2.01 * Fixed issue with handling 'DFLT' BOFM opton
Version 2.00 * Initial Release.
1.2 Changes
The following changes have been made to the BIOS for FC/FCoE Adapters between versions 2.00 and 2.14.
* Added check invalid LUN when configuring boot target (ER105664). * Added support for P3P * Fix bug that cause external looback to fail (er71773). * Added support for Hilda * Fixed bug in EDC update code. * Added code code to check for non-EDC HBA's in CTRL-Q utility. * Added code to use Echo Test instead of Loopback for F_PORT connection. * Added code to update EDC. * Removed support for CLP strings. * Added check for SSDID = 176h for EDC. * Changed Link-up timer to 30 seconds. * Added code to update MAC address if PXE BOFM MAC address configured. * Fixed bug in setting buffer pointer. * Changed code to not Disable BIOS when no BOFM drives configured. * Added code to save a backup copy of NVRAM data and use it if primary is corrupted. * Fixed bug in restoring MAC Address. * Added support for ISP8001. * Fixed comestic bug is CTRL-Q utility in displaying selectable boot lun. * Changed code to correctly display boot device type. * Removed 8G support for QMI2572 * Added support for UEFI environment. * Changed code to return good status when 'FC' section not found in BOFM. * Removed check for 'Comsumed' flag when setting BOFM targets. * Fixed issue with KVM. * Added code to setup EDI for alternate adapter. * Fixed issue with handling 'DFLT' BOFM opton
1.3 Bug Fixes
The following fixes have been made to the BIOS for FC/FCoE Adapters between versions 2.00 and 2.14
* Added check invalid LUN when configuring boot target (ER105664). * Fix bug that cause external looback to fail (er71773). * Fixed bug in EDC update code. * Added code code to check for non-EDC HBA's in CTRL-Q utility. * Added code to use Echo Test instead of Loopback for F_PORT connection. * Added code to update EDC. * Added check for SSDID = 176h for EDC. * Changed Link-up timer to 30 seconds. * Added code to update MAC address if PXE BOFM MAC address configured. * Fixed bug in setting buffer pointer. * Changed code to not Disable BIOS when no BOFM drives configured. * Added code to save a backup copy of NVRAM data and use it if primary is corrupted. * Fixed bug in restoring MAC Address. * Fixed comestic bug is CTRL-Q utility in displaying selectable boot lun. * Changed code to correctly display boot device type. * Changed code to return good status when 'FC' section not found in BOFM. * Removed check for 'Comsumed' flag when setting BOFM targets. * Fixed issue with KVM. * Added code to setup EDI for alternate adapter. * Fixed issue with handling 'DFLT' BOFM opton
2. Known Issues
None
3. Notices
Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
4. Contacting Support
For further assisance, contact QLogic Technical Support at: http://support.qlogic.com
Trademarks
Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
(c) Copyright 2012. All rights reserved worldwide. QLogic and the QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
=============================================================================== B.
QLogic Driver Release Notes
QLogic Corporation. All rights reserved.
Table of Contents
1. Change History 2. Known Issues 3. Notices 4. Contacting Support
1. Changes History
2.51 (07/17/13)
* Removed trailing spaces from HII strings. Fixes a UCM issue. (ER109139)
2.49 (05/24/2013)
* Add support for IFM/UCM interaction. (ER107060)
2.48 (05/08/2013)
* Add fix in UEFI Driver for Selective LUN Login/Selective LUN Login option to make it compatible with BIOS Selectable Boot option. (ER105967) * Add fix for WWN Database Page Title. (ER106691) * Add Spin up Delay option in HII menu. (ER105860)
2.47 (02/12/2013)
* Modified Controller name string of device as suggested by IBM. (ER102498)
2.46 (12/19/2012)
* Add fix in EFI driver, when BOFM is disabled.
2.45 (10/11/2012)
* Updates for driver listing on Driver health protocol support.
Efiutil:
3.17
* Add fix for 25xx ver_info command (ER 104543)
3.16
* Removed hardcoded subystem id check (ER0103883) * Replaced with MBI image traverse for ssid match (ER0103883)
3.15
* Fixed ambiguity in firmware version display. (ER0103456)
3.14
* Added all83xx command line switch. (ER96647) * Added support for new 26xx and 83xx cards. (ER96647)
3.13
* Added 83xx CNA support in Efiutil. (ER93221)
3.12
* Added support for 83xx family in Efiutil. (ER88039)
2. Known Issues
* Efiutil does not support the 2.0 Shell. Please load the 1.0 Shell before running Efiutil.
3. Notices
Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
4. Contacting Support
For further assistance, contact QLogic Technical Support at: http://support.qlogic.com
Trademarks
Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
(c) Copyright 2013. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
=============================================================================== C. QLogic Fibre Channel 8Gb FCode Release Notes QLogic Corporation. All rights reserved.
Table of Contents
1. Change History 2. Known Issues 3. Notices 4. Contacting Support
1. Change History
These release notes describe the changes, fixes, known issues, and release details that apply to the FCode for the 25xx Fibre Channel Adapters version 3.00
1.1. FCode Version History
version 3.20 01/11/13 * ER102374: Display Product-ID string in VPD area during initial selection. * ER94574: Fix stack bug in .adatper-info, found in blade hotplug test by efcode
version 3.19 04/09/12 * Add check for MBAR2 (Multi-Queue memory) and create reg property if it exists.
version 3.18 03/30/12 * Make validate-nvram silent. Print messages only if debug-flash?(x1000) is set. * Added dynamic sizing of the BAR registers at probe-time for reg property. * Remove dis-exp (disable-exprom) in ena-reg-acc. Causes problem on SPARC T3-1B. * Fix bugs in search of Card-Type-Lists for SSDID when flashing w/find-ilt-code. * Change oem property to QLogic or Oracle, and manufacture property to QLogic.
version 3.17 12/01/11 * Added SSDID check to set-edc-config. Print Not supported message if not Guppy. * Stripped ISP2400 & SUN specific code using #ifdefs to reduce IBM size by .5KB * Added EDC FW area in Flash and added write-sfp and read-sfp mailbox commands * Added set-edc-config, edc-update?, and edc-present! words to nvram.fth.(IBM) * Added check-edc-load and load-edc-fw words to init-isp.fth for Guppy.(IBM)
version 3.16 09/30/11 * Change PCI-Cmd-Reg value, pci-cmdv, to x146. Add System Error Resp Enable. * Change MBAR0 size (/regs) from x1000 to x4000 to include MSI-X table. * Add setting Prefetchable bit if enabled for MBAR0 in map-ifp-regs(read-bar). * Fix close-hardware to logout-devices if Link-up?, not done-fw-init? flag. * Add "Problem fixed" printout when validate-nvram fixes the backup copy. * Change init-image & init-fw to return error? flag on stack so you can abort. * Fix all mboxs commands to write 0 to all mboxes used by FW, don't assume =0. * Add clr-flags after a wait-for-risc-int timeout, which will restart the FW. * Change all Copyright messages to: "Copyright 1999-2011". * Change mbox-test to actually do some pattern testing and compare data. * Added 31 second SW timeout for IOCB & mailbox commands in wait-for-risc-int. * Add retry SCSI command once if IOCB timeout & 8048 Recv. error AEN received. * Fix stop-fw mailbox command. Clear Bit 1 (Transition to ROM Code) in Mbox-1.
* Utility/Debug changes 1 Change version method for INIT only version to also show FW version. 2 Change find-ilt-code to check Chip-Rev & Card-Type-List in ILT header search 3 Change ilt-valid? to check for Signature Word "QILT" and ILT veersion field 4 Add "Load Raw FW image?" prompt and max-FW-code-size check to ldfw method. 5 Add debug? option debug-probe? (x10000) to disable card access during probe. 6 Fix bug in flash utility which was not setting my_did if the FLT is invalid.
version 3.15 09/29/10 * Utility/Debug changes 1 Add debug? flag: 8000= Dump all mailboxes on all AENs and all Mbox commands. 2 Fix problem in ldfcode Flash utility. INIT version was not setting my_did.
* Boot-wait-time related changes 1 Change boot-wait-time back to v3.12. Now link-down-to will wait if enabled. 2 Change device-present? to exit immediately if the link-up? flag is not true. 3 Fix show-children to not use boot-wait-time for link-down-to timeout value. 4 Fix device-present? to not restart BW-timer. Start-time set in isp-fw-ready?.
version 3.14 04/30/10 * Change validate-nvram to compare only the NVRAM area, not the entire sector. * Change makefile to used the DID variable for the File name & in PCI header.
version 3.13 03/26/10 * Remove Hard-RICS-reset from reset-risc method & add 100ms delay after reset. * Make old-sb (old sec-buf) an instance value. Problem on M3000 (ER70453). * Fix Explicit logout-device IOCB to include the ISP PortID and Port WWN. * Change login-devices to not logout with FC_Initiators.
* Boot-wait-time related changes * Change get-to-params to set boot-wt = 8 secs if boot-wait-time is disabled. * Change set-boot-wait-time to not affect link-down-to (timeout) for Fujitsu. * Change set-boot-wait-time to be entered/display in decimal, not hex(Fujitsu).
* Additions made for debugging: 1 Changed debug? flags: 4000= Got-R2H-intr, 2000= IOCB-Dump, 800=FW-Ready-wait 2 Add Parameter 1 debug display on login IOCB faliure. 3 Add force-open-ok? test flag in open method. Default = true(no real change).
* Changes to make process and Flash utilities: 1 Use OpenBIOS Toke Tokenizer to make isp2500. 2 Add Sun-Style-Checksum option OpenBIOS Toke for SUN isp2500.
Version 3.12 01/11/10 * Fixed sunid (SUNW,qlc) for the SUN CNA QLE8142. The SSDID is 183, not 182. * Add flashing support for mpi-config-image from Image-Layout-Table(ILT) File. * Add check for Card-Type & Swap bits in Image-Layout-Table(ILT) Flash utility.
Version 3.11 12/11/09 * Add support for Sun (SUNW,qlc) CNA QEM8152.
Version 3.10 12/02/09 * Add support for Sun (SUNW,qlc) CNAs QLE8140, QlE8142, QLE8150, & QLE8152.
Version 3.09 * Fix Node-Name-Option bit preservation in restore-default-settings.
Version 3.08 * Fix default WWNN & WWPN preservation in restore-default-settings. * Add standard properties. Use m4 utility to automaticly create date string. * Add file rev_level.m4 which has the revision level strings only. * Change messages "Login failed" to "Login Abort". "Error Subcode" to "Subcode". * Remove patch of PCI header image size byte at offset 0x2c from init version.
Version 3.07 * Fix read-cap16-cmd. Used when the LUN size is >2TB (i.e. #blocks > 32-bits). * Fix disk-test to work with large (>2TB) LUNs, where the LBA > 32-bits. * Remove command retry when 8048 AEN is received.
Version 3.06 * Add option for qlgc-debug? in nvramrc. If the diag-switch? is true, then the debug? flag is set is set to the value of qlgc-debug?. * Add lba64 large disk capability (read-blocks64 write-blocks64) for SUN only. * Add mbox1 & mbox2 display for 8048 interrupt if debug-asyc? flag (01) is on. * Add more IOCB debugging, Add Erase Response-Queue in mapmem. Had stale data. * Add more debugging for IOCBs, dma-map-in/out, & wait-for-interrupts.
Version 3.05 * Re-structure devicepresent.fth. Add set-phandle to set obp-target & obp-portid * Fix multiple close issue found with IBM ioinfo utility.
Version 3.04 * Add alloc-sec-buf & free-sec-buf words with debugging messages. * Removed VPD validation from validate-nvram due to bug in update utilities.
Version 3.03 * Change validate-nvram to check both FC ports on Dual-port CNAs at probe time. * Fix init-flt-offsets to mask FLT attributes. Now it finds FW & Feature-key. * Add NVRAM backup Sector. Add validate-nvram at probe time to fix corruption.
Version 2.05 03/26/09 * Change all FLT Flash offset parameters from constants to values.
Version 2.04 12/03/08 * Add debug message to init-flt-offsets " Init FLT offsets" for ISP2500 only. * Add FLT and FDT Flash access methods * Remove set-bootid, set-boot-wwn, & releated qla only words from IBM version. * Added IBM debugging to BOFM words and set debug?=C00 if diag-switch is true. * Added max-payload bridge fix for 4-port QMI2564 HBA. Used Gil's method. * Fix get-mail to handle Response-Queue interrupts (stat=13) & add debugging. * Removed all Serial-Link-Control access/modify words from ISP2500 only. * Fix open to always return -1. Returning link-down fw-state fails on Serengetti
2. Known Issues
None
3. Notices M Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
4. Contacting Support
For further assisance, contact QLogic Technical Support at: http://support.qlogic.com
Trademarks
Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
(c) Copyright 2013. All rights reserved worldwide. QLogic, the QLogic
=============================================================================== D. QLogic Firmware for IBM FC Adapters (No Release Notes for Firmware) qlgc_fw_fc_8g-f70100-b214-e251_windows_32-64_chg
Integrated Management Module II (IMM2) Firmware Update Change History
Version 4.15, 1AOO58K - Suggested - Added support for the BIE (Blade IO Expansion Board) on the HS23, HS23E - Fixed a problem that prevented the AMM from controlling power when local power control is disabled on the HS23, HS23E
Version 3.60, 1AOO50C - Suggested - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM - Corrected a problem that caused the IMM to report an "Unsupported blade/blower combination" error on HS23
Version 3.50, 1AOO50B - Suggested - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Initial Release - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Suggested - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Critical - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.30, 1AOO48L - NonCritical - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Initial Release - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - NonCritical - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.50, 1AOO40Z - Suggested - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.00, 1AOO40E - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1aoo34z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Suggested - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Suggested - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Suggested - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Critical - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Suggested - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Suggested - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Suggested - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Initial Release - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Critical - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Suggested - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Critical - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Suggested - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - NonCritical - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Initial Release - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Initial Release - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Initial Release - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Initial Release - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Critical - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.30, 1AOO28M - Supports System HS23E, Machine Types: 8038,8039
Version 1.26, 1AOO26N - Initial Release - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Initial Release - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Suggested - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Initial Release - Supports System HS23, Machine Types: 7875,1929
Version 1.10, 1AOO24B - Supports System dx360 M4, Machine Types: 7918,7919
Version 1.05, 1AOO10K - Initial Release - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved.
ibm_fw_imm2_1aoo58k-4_15_bc-anyos_noarch_chg
Dynamic System Analysis (DSA) Preboot Change History
Version 9.54, Build ID DSYTD8G o Enhancement: 1. Embedded DSAp Simplification by removing Low-Value Functionality - Inventory: BIST,PMC - Diags: RSARST Diags, Tape Drive Diags, Optical Drive Diags,Check point (LED) Panel Diags 2. Heartbeat for F2 standalone memory test. 3. IBM High IOPS Adapter Raw Data Collection. 4. pDSA Simplification for FoD Function & GUI Client. 5. Add warning & report in client for nonsupport systems. 6. Change sFTP as the default protocol for transfer log to IBM Service. 7. Get standalone memory test results & SOL support for DSAp(for security efi boot). 8. Update openssl to 1.0.1h from 1.0.1g. o Limitations: 1. After finish run all diagnostics in 25 loop with Emulex 10G options, DSA log will show abnormal, it only record Diags log one time on DSA Diagnostics Completion Log. 2. On GUI, when two ports of the machine want to connect the Extranet at the same time, the machine could not send dsa log to IBM server. you can click test internet connection to solve the problem. 3. System not show event log item in chassis event log & ipmi event log page when trigger SBE in standalone mode. o Special usage: - 2014 IMMV2 2QLFC Product Build
Version 9.43, Build ID DSYTC8E o Enhancement: 1. Preboot GUI redesign and enhancement--refine GUI into more customer friendly style. 2. FoD Support--FoD key re-activation. 3. pDSA proxy auto-config retrieve. o Limitations: 1. DSA Does not support "VMware ESXi" page report for ESXi 5.x key due to "vmvisor-offline-query" limitaion . o Special usage: - 2013 IMMV2 4QLFC
Version 9.33, Build ID DSYTB6E o Limitations: When we want to flash from B5E to B6E, we should level down to AA3 or AA4 first.
Version 9.30, Build ID DSYTB27 o New System Support: Flex System x440 Compute Node (7917, 2584) IBM System x3300 M4 (7382) o Problem(s) Fixed: 1. PMR - 05766,YL2,760 Aenservice appeared after running UpdateXpress & DSA. 2. PMR - 05193,W01,000 7147 - Intermittent random PSOD in vmware. multiple
o Enhancement: None o Limitations: - FIFO test of NIC diagnostics is not supported on the Intel I350 Quad Port GbE. Powerville has shared FIFO and shared FIFO registers making a test impossible if four ports are running at once. - For more limitations please refer to readme. o Special usage: - 2012 ToolsCenter 12D
Version 9.29, Build ID DSYTAB6 o New System Support: Flex System x440 Compute Node (7917, 2584) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - NGP-4Q(12B+ FixPack3)
Version 9.28, Build ID DSYTAA4 o New System Support: x3630 M4 (7519) x3550 M4 (7383) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - IMMV2 system 2012 4Q-LFC
Version 9.27, Build ID DSYTA7F o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme o Special usage: - IMMv1 system 2012 4Q-LFC
Version 9.26, Build ID DSYTA6G o New System Support: None o Problem(s) Fixed: None o Enhancement: DSA Performance Optimization o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12C
Version 9.21, Build ID DSYTA1U o New System Support: None o Problem(s) Fixed: 1.Recovered LSI Rawdata: "MegaCli -FwTermLog -Dsply -aALL" o Enhancement: None o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B Plus
Version 9.20, Build ID DSYTA0R o New System Support: x3530 M4 (7160) x3630 M4 (7158) x3750 M4 (8722, 8733) HS23E (8038, 8039) Flex System x220 Compute Node (7906, 2585) o Problem(s) Fixed: 1. PMR 05819,YL2,760 An error occured during the execution of DSA on Windows, DSA exits with an error at the eventlog plugin. o Enhancement: 1. Add HW remote presence key collection for High volume systems. o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B
Version 9.07, Build ID DSYT9CA o New System Support: x3750 M4 (8722, 8733) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.06, Build ID DSYT9BC o New System Support: Flex System x220 Compute Node (7906) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.05, Build ID DSYT9AA o New System Support: x3630 M4 (7158) x3530 M4 (7160) x3100 M4 Refresh1 (2582) x3250 M4 Refresh1 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.04, Build ID DSYT99E o New System Support: Flex System x240 Compute Node (8737, 8738, 7863) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.03, Build ID DSYT98I o New System Support: HS23E (8038, 8039) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.02, Build ID DSYT97C o New System Support: iDataPlex dx360 M4 server/2U chassis (7912/7913) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.01, Build ID DSYT96D o New System Support: x3500 M4 (7383) x3550 M4 (7914) x3650 M4 (7915) o Problem(s) Fixed: o Enhancement: None o Limitations: None o Special usage: None
Version 9.00, Build ID DSYT95W o New System Support: BladeCenter HS23 (7875) BladeCenter HX5 (7873, 1910) Flex System x240 Compute Node (8737, 8738, 7863) Flex System Manager Node (8735) x3500 M4 (7383) x3550 M4 (7914) x3630 M4 (7158) x3650 M4 (7915) x3690 X5 (7192, 7147) x3850 X5 / x3950 X5 (7143, 7191) o Problem(s) Fixed: 1. PMR 24817,8QG,000, PMR 30680,499,000 After kicking off DSA on one of the management nodes (x3650 M2) of SONAS 1.2(RHEL5 based), the node became unresponsive and dropped out of the cluster.
2. PMR 53575,000,834, PMR 05961,YL4,760 After running DSA, when using linux dump command on a DDS5 usb internal tape drive attached in x3650M2 backup speed becomes very slowly or failed.
3. PMR 26905,095,866 Running DSA 4.0 as well as DSA 3.4 on x3850 X5 the server is freezing, users have to reboot the server.
4. DSA 4.00 and previous version segmentation fault issue
6. PMR 15086,OTH,760 DSA 9.00 with --no-imm-lan option does not work correctly on RHEL5.3. The USB port state is changed during the execution of DSA.
o Enhancement: 1. Add GUI and CLI menu for Features on Demand (FoD) Activation Key Management o Limitations: Refer to readme. o Special usage: None
Version 4.02, Build ID DSYT92I o New System Support: iDataPlex Direct Water Cooled dx360 M4 server o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 4.01, Build ID DSYT92H o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 4Q lifecycle
Version 4.00, Build ID DSYT91S o New System Support: None o New server options support: None o Problem(s) Fixed: 1. PMR 15065,OTR,760 On Unisys ES7000 or x3850 X5, the Memory Card number with failed DIMM can not be reported in IPMI Eventlog if the Memory Card is bigger than 4.
o Enhancement: 1. Added > 1TB memory test support o Limitations: Refer to readme. o Special usage: - 2011 ToolsCenter 11D
Version 3.48, Build ID DSYT89PUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 3Q lifecycle
Version 3.47, Build ID DSYT89LUS o New System Support: x3100 M4 (2582) x3250 M4 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.46, Build ID DSYT89GUS o New System Support: System x iDataPlex dx360 M3 (6391) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.45, Build ID DSYT89EUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - x3850 X5 / x3950 X5 (7143, 7191) EXA scaling
Version 3.43, Build ID DSYT87HUS o New System Support: BladeCenter HX5 (7873,1910) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.43, Build ID DSYT87FUS o New System Support: x3850 X5 / x3950 X5 (7143, 7191) x3690 X5 (7192, 7147) o Problem(s) Fixed: o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.40, Build ID DSYT85T o New System Support: BladeCenter HS22 (1911) x3650 M3 (5454) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.30, Build ID DSYT80S o New System Support: None o Problem(s) Fixed: None o Enhancement: 1. Correct a problem with LSI MegaRAID reporting for IBM Service o Limitations: Refer to readme. o Special usage: None
Version 3.20, Build ID DSYT75X o New System Support: x3630 M3 (7377) x3690 X5 (7148, 7149) o Problem(s) Fixed: None o Enhancement: 1. Add LSI Hard Disk Drive (HDD) diagnostic back for both the onboard SAS chip and ServeRAID o Limitations: - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Verion 3.20, Build ID DSYT75U o New System Support: x3755 M3 (7164) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Verion 3.10, Build ID DSYT70X o New System Support: x3400 M3(7378, 7379) x3500 M3(7380) x3550 M3 (7944, 4254) x3620 M3 (7376) x3650 M3 (7945, 4255) x3690 X5 (7148, 7149) x3850 X5 Standard Single-node and Multi-node models(7145, 7146) x3950 X5 Specially configured Database Engine models (7145, 7146) iDataplex dx360 M3 (6391) HS22V (7871,1949) HX5 (7872, 1909) o Problem(s) Fixed: None o Enhancement: 1. Added ServeRAID data collection o Limitations: - The following function has been temporarily removed from DSA Preboot for both the onboard SAS chip and ServeRAID: - LSI Hard Disk Drive (HDD) diagnostic - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Version 3.02.56, Build ID DSYT56e o New System Support: None o Problem(s) Fixed: None o Enhancement: - The following systems are supported when BoMC downloads the corresponding system enablement pack: HS22V (7871,1949) x3550 M3 (7944,4254) x3650 M3 (7945,4255) x3400 M3 (7378,7379) x3500 M3 (7839) dx360 M3 (6391) o Limitations: - No HDD diagnostics available - To ensure quality and stability of the DSA code, we have reverted some display functionality of RAID information to what was shown in previous versions of DSA. This affects RAID display on the following adapters: Megaraid 8480 Serveraid MR10i Serveraid MR10is Serveraid MR10m Serveraid MR10k Serveraid M1015 Serveraid M5014 Serveraid M5015 On these adapters, the RAID information is generated from the output of separate command line tools and the format may not match other output in DSA. - For more limitations please refer to readme o Special usage: None
Version 3.00, Build ID: DSYT55a o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7327, 7328, 4251, 4252, 4261 o Limitations: - No HDD diagnostics available - For more limitations please refer to readme o Special usage: None
Version 1.16, Y4YT19AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7839, 7836, 7837 o Limitations: None o Special usage: None
Version 1.15, TMYT20AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7321, 6380, 7323 o Limitations: None o Special usage: None
Version 1.14, D6YT37AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7946, 4198, 7947, 4199 o Limitations: None o Special usage: None
Version 1.13, P9YT48AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7870, 1936, 7809 o Limitations: None o Special usage: None
Version 1.00 - Initial release
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved. ibm_fw_dsa_dsytd8g-9_54_anyos_anycpu_chg
=============================================================================== Emulex NIC Device Driver for Windows ===============================================================================
Driver version: 4.6.203.1 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - HyperV VM's tagged VLAN's did not get an IP Address - NIC Function Properties > Status for PCI Express Link Speed says Invalid Link Speed detected. - iSCSI ports of CNA card in ESXi 4.1u3 OCM GUI (vCenter plug in) is not getting displayed
Driver Vers: 4.4.176.2 (Previously supported on IBM Flex) Driver Vers: 4.2.390.6 (Previous Release for IBM Rack & BladeCenter)
Problems Fixed: - Cleaned up inf file - TOE Offload Fails when the same neighbor is added more than once
Incremental Interoperability: - Windows 2012
Known Issues: - Switch Independent Mode not supported in a HyperV environment - Default values vary between inbox and out of box drivers. For example: Configuration section - Wake On LAN - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ Performance section - Maximum Number of RSS Queues - Inbox default is ‘4’ - out-of-box default is ‘8’ - Virtual Machine Queues - Inbox default is ‘Disabled’ – out-of-box default is ‘Enabled’ You may select the button to reset all driver settings to defaults after any installation.
Driver Vers: 4.1.370.0 (Previously supported on IBM SystemX, BladeCenter & Flex)
Incremental Interoperability: - Initial release for IBM Flex
Problems Fixed:
- HS23 - Sleep Stress test failed with bugcheck C4 during driver verify - TOE with RSC enabled causes Network to go down - Augmented WOL Capabilities - Driver parameter query failures - BSOD 9F during shutdown if device stops responding - RSS queues may change port during MPRestart and MPPause
Driver Vers: 4.1.334.25 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Emulex: Large Receive Offload support needed in Windows NIC driver - Win WoL: Need to report WoL based on ARM reported capabilities - update the driver strings for existing cards - RSS code may access PerMessage beyond end of array - 16 queue RSS for BE3 on Windows 2008 R2 - fix unverified mode of occfg to allow customer workarounds - 16 queue RSS lockup if SRIOV enabled in registry - Standard Property Page for 1 port Windows Azure card - Timeout RQ flush to avoid bugcheck during shutdown - Change receive buffer alignment to use Windows 2008 R2 TCPIP fast path - Emulex: BSOD - Replacing BE3 card with a BE2 card after installation of new kit driver and firmware on Win 2k3 SP2 R2x64 (vNIC enabled IBM machine) - be2nd62.inf failed ChkInf - VMQ registry keys displayed in Windows 2008 - be_function_prepare_nonembedded_ioctl overwrites version field - autoi reboot fails on Win2K8 x64 when verifier enabled - PCI ID: Updates for Endeavor 2 for IBM- PCI IDs Rev 1.22 - Emulex NIC driver causes BSoD during shutdown whenever disable firewall or join domain network - Sleep Stress test failed with bugcheck C4 during driver verify - Disable TOE by default for IBM - BSOD 9F during shutdown if device stops responding
Driver Vers: 4.0.317.0 (Previously supported on IBM SystemX & BladeCenter) elx_dd_nic_ibm1212-4_6_203_1-6_windows_32-64_chg
QLogic 10 GbE Converged Network Adapter MultiFlash Update for System x IBM P3P Firmware Change History QLogic Corporation. All rights reserved.
Release Version: 2.20.04
Table of Contents 1. Version 2. Changes 3. Limitations 4. Known Issues 5. Additional Information 6. Trademarks 7. Notices 8. Contacting Support
1. Version
The files contained in this Flash image package are zipped into a file that will expand to provide the following versions for the 3200/8200 Series Adapters.
* Flash Image Version 2.20.04
P3P22004.BIN contains: ---------------------- * NIC PXE (3200/8200 Series) PXE 3.0 version 2.0.2.31 PXE EFi version 2.6.13 * FCoE BIOS (8200 Series only) BIOS 3.0 version 3.24 uEFI version 6.07 * iSCSI BIOS (8200 Series only) BIOS 3.0 version 2.19 uEFI version 2.04.03 * Firmware - v4.16.34 * Pegtune - v4.16.32 * Bootloader - v4.16.05 * CRBinit - v4.12.07
Hardware Support Standard Servers with PCIe 1.1 and 2.0 x8
3. Limitations
None
Industry Standards Compliance N/A
4. Known Issues
5. Additional Information None
6. Trademarks Accelera, Accelerating Cluster Performance, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, QLA, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
7. Notices Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
8. Contacting Support Please feel free to contact your QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached at:
Gary Stift gary.stift@qlogic.com
(c) Copyright 2011. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners.
qlgc_fw_cna_sysx-2_20_04_windows_32-64_chg
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.3 Latest Driver Version: 3.2.3.0 Document Updated: 05/30/2013 Product: Brocade FC/NIC/CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for UEFI Health Check Protocol
Fixes and Enhancements: - Enhanced Windows Network performance
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381"
Fixes and Enhancements: - Enhanced windows Hyper-V driver to avoid a infrequent crash seen during shutdown with VMQ enabled
Version 3.2.0.0 Release for FC/NIC/CNA
New Features and Feature Enhancement: - Updated code for Brocade 1867 IBM Flex System FC5022 FC Adapter for x22 - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Fixes or enhancements: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Version 3.1.0.1 Release for 16G FC/NIC/CNA
Adapter Features - Updated code for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A
Version 3.0.3.1 Initial release for 16G FC/NIC/CNA
Adapter Features - Initial support for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A brcd_fw_cna_3_2_3_0_windows_32-64_chg
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.3.1 Latest Driver Version: 3.2.3.1 Document Updated: 10/08/2013 Product: Brocade FC/FCoE/NIC
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.3.1 New Features and Feature Enhancement: - Support for Windows 2012 R2
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for UEFI Health Check Protocol
Fixes and Enhancements: - Enhanced Windows Network performance
Version 3.2.1.1 Fixes and Enhancements: - Firmware update to address the thermal notification issue
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381"
Fixes and Enhancements: - Enhanced windows Hyper-V driver to avoid a infrequent crash seen during shutdown with VMQ enabled - Included windows 2012 Driver Update Disk (based on windows 2008 R2 DUD)
Version 3.2.0.0 New Features and Feature Enhancement: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Fixes or enhancements: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Version 3.1.0.1 Key features and enhancements supported for the software release 3.1.0.1 include the following:
New Features: - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage
New Operating System Support: - Windows Server 2012
Fixes or Enhancements: - On Windows 2008 or 2008 R2, resolved an issue where HCM may freeze intermittently when Team(s) or VLAN(s) are configured. - Improved stability with Hyper-V and Teaming configurations. - On Windows 2008 or 2008 R2, resolved an issue that could stall network traffic during heavy traffic load.
Version 3.0.3.0 Initial release for 16G FC Adapter Features - Initial support for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A brcd_dd_cna_3_2_3_1_windows_32-64_chg