ServeRAID M1000 Series SAS/SATA Controller Firmware Update
Adapters Supported: ServeRAID M1115 SAS/SATA Controller for IBM System X (81Y4448) ServeRAID M1015 SAS/SATA Controller (46M0831)
Version 20.10.1-0107 - Suggested ------------------- Fixes: - Fixed grammatical errors in WebBIOS. - Fixed an issue in WebBIOS Drive Group Definition screen where enclosures should not be selectable in the Drives column. - Fixed an issue in uEFI-WebBIOS where the white bars do not match up under VD properties page. - Fixed an HII browser issue where a drive performing a copyback displayed the state as "Replacing" but other utilities showed the state as copyback. - Fixed an HII browser display issue where SATA drives showed "0" for the value of RPM under drive properties. - Fixed a display issue where the HDD port number showed incorrectly in an HII browser. - Fixed an HII browser issues where creating a global hotspare gave the user an error message. - Fixed an HII browser issue when security is changed with local key management the changing security report current mode is disabled as external keu management. - Fixed an HII browser issue where the user got the following error message, "The request command has invalid arguments," when changing the security key report. - Fixed an HII browser issue where the user was unable to save the configuration after adding an extra span during array creation. - Fixed an HII browser issue where the return value was not correct when the browser called extract config with a result of null.
Version 20.10.1-0101 - Suggested ------------------- Fixes: - Fixed an issue where a system uefi error will occur when the bootTargetId is set to 0. - Fixed a problem where the firmware will allocate the sata bbl entry for the drive when moved from unsupported to supported. - Fixed a firmware issue where the TargetId for the recon LD should be set to its original LD. - Fixed a HII error message "Question Value mismatch with Option value!" after selecting factory defaults in HII. - Fixed an issue where the firmware fails to create the configuration and utilities fail to report the VD size after the reconstruction.
Version 20.10.1-0091-01 - Non-Critical ------------------- Fix - Fixed issue where update may fail to find all supported controllers in SLES 11 SP 2. Note not change in the firmware; it is the same as package 20.10.1-0091.
Version 20.10.1-0091 - Suggested ------------------- Enhancement: - Add support for ServeRAID M1115
Fixes: - Fixed issue where after starting a reconstruction on a RAID 0 the progress %, does not increase. - Fixed an issue where a new drive, inserted after a drive failure, goes to JBOD and not auto rebuild. - Fixed physical drive count issue that stated more than (16) devices already exists
Version 20.10.1-0069- Suggested ------------------- Enhancement: - ServeRAID M1015 Dimmer Switches are disabled by default.
Fixes: - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Fixed issue where WebBIOS gives garbled message when enabing FDE on an existing Disk Group - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed a problem where firmware was taking to long to complete the PCI config read. Causing the system to generate an NMI. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed an intermittent RAID key failure during power-on.
Version 20.10.1-0052- Critical ------------------- Enhancement: - Add support to pass SMART errors for JBOD drives to MSM
Fixes: - Added check to return SCSI sense Check condition if PMI is set and LBA is non zero for SCSI Read Cap 16. - Fixed issue where a bluescreen occurs handling RAID 1 with HSP and medium errors. The bluescreen occurs becausethe driver timesout while fw is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early
Version 20.10.1-0045 - Critical ------------------- Fix: - Fixed issue where firmware has incomplete writes during power fail and recovery
Version 20.10.1-0036 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users to downlevel firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur
Version 20.10.1-0022 - Critical ------------------- - Fixed issue where Windows 2008 R2 WS08 cannot be installed properly on ServeRAID M1015 SATA JBOD with a uEFI boot. - Added warning message when user tried to change more then 16 drives to JBOD. - Addressed a problem where direct attached drives are given incorrect slot numbers - Added fixes from LSI channel products. - Fixed issue where a single JBOD drive will not boot after a Windows 2008 R2 installation.
Version 20.5.1-0014 - Critical ------------------- - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed problem where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 20.1.1-0059 - Critical ------------------- Fixes: - Fixed an issue where a physical drive that is changed to JBOD from powersave will become unconfigured good again - Addresses an issue where data becomes inaccessible when a drive is secured after data has been written
Version 20.1.1-0049 - Suggested ------------------- Enhancement - Support M1000 key for RAID 5 and SED support
Fixes: - Fixed an issue in M3950M3 where webbios would hang - Fixed an issue where the controller properties in WebBIOS such as Rebuild, CC and BGI are not changing when we use up and down arrow keys. - Fixed an issue where Enclosure ID's are not being shown in MSM
Version 20.1.1-0046 - Suggested ------------------- - Enabled support for the ServeRAID M1000 Series Advanced Feature Key.
Note: All Logical Drives must previously have the encryption enabled before data is written on to the SED drives. Please read Retain TIP H123152 for more details.
Version 20.1.1-0042 ------------------- - Initial release ibm_fw_sraidmr_m1000-20_10_1-0107_linux_32-64_chg
Integrated Management Module (IMM) Firmware Update Change History
IMPORTANT: Prerequisite for updating to IMM firmware version 1.30 (yuooc7e) ========== Updating to IMM firmware version 1.30 (yuooc7e) requires the current IMM firmware version to be 1.10 (yuoo57h), or later. If this prerequisite is not met before updating to version 1.30 (yuooc7e) the system will not power on correctly. If the system is not running a minimum of IMM version 1.10 (yuoo57h), update the IMM before attempting to update to 1.30 (yuooc7e). This prerequisite was a limitation of IMM version 1.30, and it has been fixed in IMM version 1.31(yuooc7f). This prerequisite does not apply to IMM version 1.31 or later.
IMPORTANT: Please DO NOT apply the firmware update (yuoo91e, v1.24) ========= if you are using AEM functions in x3620M3 or x3630M3. The v1.24 firmware will disable the power capping functionality in those two systems. Please remain on the current IMM version or update the firmware to v1.25 or newer. Users not using AEM functions can still update to v1.24.
IMPORTANT: Read before using the MAX5 ========== This Technical Update supplements the documentation that comes with the IBM MAX5 for System x. Keep this document with your other MAX5 documentation. Before you attach the MAX5 to the server and try to use it, you must update the server firmware with the latest level of firmware or code. If you attach and try to use the MAX5 without updating the server firmware, you might get unexpected system behavior or the server might not power on. For special instructions to follow before you attach the MAX5 to the server, go to http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085756.
IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to http://www.ibm.com/systems/support/ and follow the instructions.
IMPORTANT: If you are at IMM firmware versions prior to 1.12 (yuoo67c) and ========== updating IMM firmware in Microsoft Windows, when you update IMM to versions between 1.14 (YUOO73M) and 1.30 (YUOOC7E), it will take up to 10 minutes additional wait time; when you update IMM to version 1.30 (YUOOC7E) or later, it will take up to 20 minutes additional wait time. This is due to the iflash tool checking the IMM before flashing. During this time the flashing process may appear hung or unresponsive. The flashing will then complete and there is no functional impact.
IMPORTANT: Make sure the current IMM firmware level is 1.14 or later ========== before you update the uEFI, FPGA, or DSA Preboot firmware. The recommended firmware update sequence is IMM followed by UEFI followed by FPGA followed by DSA Preboot.
IMPORTANT: A firmware change was made in YUOO57H (v1.10) that enforces the ========= requirement for login accounts on the IMM to have passwords that contain both alpha and numeric characters. If you are updating the IMM firmware from YUOO56K (v1.09) or earlier, to YUOO57H (v1.10) or newer, prior to updating the firmware, please ensure that the IMM user account passwords contain both alpha and numeric characters. If the firmware is updated and the passwords do not contain both alpha and numeric characters, you may need to reset the IMM to its default settings using the menus in the UEFI F1 set up display.
IMPORTANT: When updating the IMM firmware from a version earlier than ========= version 1.05 (build YUOO32F) to version 1.05 or newer, the Remote Alert Recipient Email Addresses and the Daylight Saving Time setting will revert to the default setting. Users that utilize these settings will need to set them again after the update.
IMPORTANT: When updating IMM, uEFI, pDSA, FPGA via any method, ========== please follow firmware update best practice document (http://www-947.ibm.com/support/entry/portal/docdisplay?brand= 5000020&lndocid=MIGR-5082923) for suggested update sequence and prerequisite.
IMPORTANT: Due to an Intel errata, if your server is running a 32-bit Linux ========== Operating System, C-states may need to be disabled while updating uEFI, IMM, or DSA Preboot through the Linux command line interface. See RETAIN TIP H195678 for more information. Updates performed through the AMM, Bootable Media Creator, or the IMM web or CLI interfaces do not have this requirement.
IMPORTANT: Updated firmware version numbers might not be visible in SMBIOS ========== tables until after the server is rebooted.
IMPORTANT: After downgrading IMM firmware from version 1.22 ========== to an earlier version, the user needs to reset the IMM to factory default before normal operation.
Version 1.40, YUOOF7A Problems Fixed: - Fixed the problem that host OS will be shut down due to wrong overtemp event. - Fixed the problem that "unsupported software version" could be showed in event logs after updating IMM version 1.30 or newer on x3850/x3950 X5, x3690X5 and HX5 - Fixed the problem that SMTP user name field on IMM web page only allows 16 chars. - Fixed the problem on HS22 where IMM reports 0 watt power during initialization
Enhancements: - Enabled IMM to fail over to backup automatically when there is a IMM firmware corruption - Enhanced IMM web GUI response. - Added notification when a corrupted GUID Partition Table (GPT) is encountered by UEFI during POST. Please refer to RETAIN Tip H207759 for details. - Enhanced logging for Power Controls management.
Version 1.39, YUOOF2C Problems Fixed: - Fixed the problem on IBM System x3850X5 where SAP HANA configurations can reset in rare cases. More details in RETAIN Tip H207295.
Version 1.38, YUOOF2B Problems Fixed: - Fixed the problem on x3850 X5/x3950 X5 where the System Fault LED will be lit when only one PSU is installed.
Version 1.37, YUOOE9C Problems Fixed: - Corrected the voltage sensor threshold for HS22 and HS22V system.
Version 1.36, YUOOF2A Enhancements: - Improved IMM web page Accessibility
Version 1.35, YUOOE9B Problems Fixed: - Fixed the thermal issue for Broadcom quad port ethernet (IBM PN 49Y7948., FRU 49Y7949). - Fixed the problem that user authentication for LDAP with SSL will fail when Configured Credentials is enabled. - Updated the thermal profile for NVIDIA M2090 GPU card support in dx360 M3. - Fixed the problem on HS22 systems where pressing the KVM button too soon (right after Power LED starts blinking slowly) would make the KVM owner unable to be changed. - Fixed the problem on blade servers where IMM may report the "Unsupported blade/blower combination" error for 130W Westmere CPUs. - Fixed the problem on x3200 M3 where when power policy is set as "restore" or "always on" in uEFI, enforcing system shutdown during POST will cause automatic system boot-up. - Fixed the problem about SNMP drops intermittently and SNMP data cannot be accessed in a period of time - Fixed the problem on x3850 X5/x3950 X5 Multi-Node systems where "redundancy lost" event is not logged in the Primary Node when one of the power supplies in the Secondary Node is lost. - Optimized CPU power consumption calculation method for x3690 X5. - Fixed the problem on blade servers where IMM does not automatically recover NCSI. - Fixed the problem on blade servers that IMM constantly has "Init Failures" and fails to start up. - Fixed the Readme file problem that some IP addresses of LAN-over-USB instructions are inconsistent. - Fixed the CMOS Voltage Over Threshold problem on HS22V systems. - Fixed the problem that SSH login failed when the setting is configured as "Local first then Ldap" or ldap settings are not valid. - Fixed the problem that the IMM web interface responds too slowly or even fails to respond.
Enhancements: - Enhanced the entropy (randomness) when generating SSL keys. - Added secure SMTP authentication support. - Added I/O board VPD information in IMM web interface - Added the function of letting Location LED remain on after system power-off. - Enhanced event Severity reporting of the QPI Link LED on x3850 X5/x3950 X5 so that IBM Director can interpret it correctly. - Improved IMM version reporting for IBM Director. - Added a function to keep 110V Power Supply Redundancy by throttling the system for x3850 X5/x3950 X5. - Usability enhancement: all events will be checked by default on the alert setting web page. - Enabled ASU to control each sub-category for email alert recipient setting and SNMP alerts setting. - Added new BCH Midplane (that supports 8Gbit Fibre Channel) support. - Added the function to capture all IMM logs with one button click. - Enhanced the DataPower appliance blade support.
Version 1.34, YUOOE3E Enhancement: - Add support of the following fusion-io adapters : 1.2TB High IOPS MLC Adapter for IBM System x 2.4TB High IOPS MLC Adapter for IBM System x 365GB High IOPS MLC PCIe Adapter for IBM System x 785GB High IOPS MLC PCIe Adapter for IBM System x
Version 1.33, YUOOE3C Problems Fixed: - Fixed the problem that the "Date" header is missing from the IMM SMTP trap. - Fixed the problem that the "Look Below" LED (CR48) on x3690 X5 Memory Expansion Board may turn on incorrectly when there are no errors detected. - Fixed the problem on x3850 X5/x3950 X5 where the system information in the IMM configuration file may be truncated and the incomplete system information will cause the HTTP server in IMM run into an unstable state. - Fixed the problem that the Scalability LED turns off after the IMM on either node of a 2-Node x3850 X5/x3950 X5 is reset. - Fixed the problem that IMM on x3850 X5/x3950 X5 might fail to start after the IMM firmware is successfully upgraded. - Fixed the problem where "Comm Errors" may occur when the IMM firmware on HX5 is upgraded. - Fixed the problem that dx360 M3 may have PCI errors when a NVIDIA M2090 GPU card is installed. - Fixed the problem that opening the ActiveX remote console closes all open tabs in the same Internet Explorer window. - Fixed the problem that x3550 M3 may occur ServerRAID BBU over temperature and ServerRAID M5016 over heat issues.
Enhancements: - Added Internet Explorer 9 support. - Changed the maximum User's Distinguished Name(DN) for LDAP from 128 bytes to 256 bytes. - Removed the limitation of 255 memberOf groups for an LDAP user in IMM. - Enhanced IMM Web session management. - Added an IMM command line (CLI) command for one time PXE boot option setting. - Added a new unique error code in AMM and changed the text in AMM and IMM for CMOS battery errors. - Updated Russia time zone definition to no more daylight saving time.
Version 1.32, YUOOD4G Problems Fixed: - Fixed a problem where IMM web interface does not lock out a user if the same user exhausts login retries and gets locked out through the SSH interface - Fixed a problem that caused the IMM to report false critical DIMM temperature events - Fixed an intermittent problem where sometimes the Power Supply DC status LED is not illuminated on the x3550 M2/M3, x3650 M2/M3, x3620 M3 and x3630 M3 - Fixed a problem that sometimes causes the IMM web interface to shut down after multiple invalid login attempts Enhancements: - Added Service Advisor support on x3850/x3950 X5 and x3690 X5 - Changed the IMM firmware to allow every service port to be Enabled or Disabled - Changed the IMM firmware to not disable the network interface when there is a conflict IP address on the network - Changed the IMM firmware to permit SSL client certificates to be managed while the SSL client is enabled
Version 1.31, YUOOC7F Problems Fixed: - Fixed the problem that after updating IMM firmware from versions prior to v1.10(YUOO57H) to v1.30(YUOOC7E) the system won't power on correctly
Version 1.30, YUOOC7E Problems Fixed: - Fixed the intermittent Power Supply error on x3550M2/M3 and x3650M2/M3 - Fixed the false alarm message for ArBel Power Supply on x3550M2/M3 and x3650M2/M3 - Fixed the issue that a blade intermittently does not respond to the system management bus on HX5 and HS22/S22V - Fixed the duplicate PECI messages issue on x3850/x3950 X5, x3690X5 and HX5 - Fixed the intermittent problem that a user can not login to IMM web after inventory from IBM Director - Fixed the problem that SMTP test alert doesn't work - Fixed the problem that SNMP remote alert doesn't work - Fixed the intermittent IMM reset problem - Fixed the SSL vulnerability issue Enhancements: - Added 64-bit ActiveX Remote Presence Client support - Added BGE overweight detection on HS22 - Added support of differentiating memory failures happening during UEFI POST and during run-time - Added support of reporting AC restore status on x3850/x3950 X5 - Added the change to include DIMM slot number info in the memory error event message
Version 1.29, YUOOB7F Problem(s) Fixed: - Fixed a problem where false memory configuration error messages are sometimes reported on the x3850/x3950 X5
Version 1.28, YUOOB7C Problem(s) Fixed: - Fixed a problem where the IMM sometimes records duplicate event log entries - Fixed a problem that caused the DIMM Bank number to not be correctly reported - Fixed a problem that prevented the system from powering on when there is a firmware mismatch - Fixed a problem that didn't allow a password to be saved if it contains a & or < character - Fixed a problem where the IMM VPD sometimes is not available on the web page - Fixed a problem where one port on the QLogic 8GB HBA card sometimes is not recognized - Fixed a problem that sometimes caused the DVD drive to disappear in RHEL5 after the IMM is reset - Fixed a false Power Supply failure message - Removed the error message pop up when changing the IMM password to default - Fixed the problem that BBU gets over temp during discharging on x3550 M3 - Corrected a problem where the BOFM address became permanent after BOFM is disabled on the AMM - Corrected a system hang when a Multi-Bit memory error occurs with a mixture of 2GB & 4GB DIMMs installed - Fixed the problem where the reported DC Power consumed on the dx360 M3 is higher than actual AC input power - Fixed the MIB mismatch issue - Fixed the incorrect OID in MIB Enhancements: - Added support for 32-bit ActiveX Remote Presence Clients - Added the ability to change the SMTP port number - Changed the firmware to completely shut down the telnet sevice when the telnet max user count is set to 0 - Added support for LDAP Active Directory Application Mode - Added support for LDAP Authentication Only Mode - Changed the firmware to report a configuration error if the CPU installed on the EXA system is not a Westmere CPU - Changed the firmware to allow the x3690X5 to be powered on sooner - Changed the firmware to decrease the amount of time that it takes for the IMM to become ready after it is reset
Version 1.27, YU00A7C Enhancements: - Added support for the IBM BladeCenter HX5(MT: 1910,7873)
Version 1.26, YU00A6A Enhancements: - Added support for the System x3850/x3950 X5(MT: 7143,7191) and System x3690 X5(MT: 7147,7192)
Version 1.25, YU0091K Problem(s) Fixed: - Fixed a problem that hangs the server when F2 is pressed during POST to start Diagnostics - Fixed a problem in the HS22/HS22v that causes the IMM to report an unexpected throttle condition after the AMM is reset - Fixed a problem that causes the IMM lose its DHCP assigned IP address - Improved the monitoring of hard drive status when the server is powered up - Fixed a problem when using a Japanese keyboard with the remote presence function - Fixed a gradual fan speed reduction due to pressure sensor fluctuation on System x3690 X5, System x3550 M2/3, System x3650 M2/3 - Improved the response to an IO Hub over temperature condition on System x3690 X5, System x3650 M2/M3, and System x3550 M2/M3 - Fixed a problem that IBM Systems Director needs to re-discover IMM in order to receive events from IMM after IMM upgrade Enhancements: - Added support for a 460W power supply in the System x3620 M3 - Added support for a 675W high efficiency power supply in the System x3620 M3 and System x3630 M3
Version 1.24, YU0091E Problem(s) Fixed: - Fixed a problem where the IMM sometimes incorrectly reports a Pwr Rail fault or Pwr 240A_A/Pwr 240A_B fault - Fixed an issue where blade would hang on boot with ABR firmware corruption message - Fixed a problem when downgrading IMM firmware from version 1.22 to earlier levels. The IMM network fails - Fixed a problem that caused the firmware update using IMM Command Line Interface to fail on an IPv6 network - Fixed a problem that caused the IPv6 Link-local address not to be displayed after resetting the IMM to its defaults - Fixed a problem where the IMM fails to set SNMP configuration using ASU - Fixed a problem where IMM cannot set the value 10 for the OSWatchdog value using ASU - Fixed a problem where IMM Remote Media would not re-initialize after network error - Fixed problem if KCS error bit status may not be clear which may cause KCS communication stop - Fixed a problem that IMM web interface hang with Remote Control session opened - Fixed a problem that blade unexpected powered on after power off command Enhancements: - Added IPv6 configuration support via IMM SNMP interface - Added support for BladeCenter PCIe Expansion 4 on BladeCenter HX5 - Added support for BladeCenter GPU Expansion on BladeCenter HS22 - Added support for LDAP sub-tree searching with Novell eDirectory 8.7 - Added support for SNMP trap definitions - Updated fan response and logic for Fusion IO PCIe adapter - Updated ambient temperature sensor calculation
Version 1.22, YUOO84C Problem(s) Fixed: - Fixed a problem where the IMM sometimes incorrectly reports a Processor 2 (CPU 2) internal error - Fixed a problem where after powering down an HS22, the HS22 powered on without user request - Fixed a problem while Log in to IMM might fail if the Host name contains a dash - Fixed a problem where the IMM makes some certificate management settings protected that should not be protected - Fixed a problem where users can't get the full details of an expansion card using the IPMI FRU command - Fixed a problem where IMM would hang after an LDAP login using some German or French characters - Fixed a problem with the IMM SMTP client not conforming to RFC821 - Fixed a problem where the email alert setting won't accept a hyphen - Fixed a problem with the Windows key in the IMM Remote Control feature - Fixed a problem where IMM login via LDAP authentication fails to acquire Supervisor authority via Group membership with an OpenLDAP server. - Fixed a problem where a user with Remote Server Power/Restart Access authority can't change the power off delay - Fixed a problem that prevented a Processor Throttled event from being logged for the x3200 M3 and x3250 M3 models - Fixed a problem that where a user's permission is always set from the LDAP account not the local account profile - Fixed a problem where the CPU2 VCore/CPU2 VDIMM sensors become unreadable after updating the IMM in the x3500 M3 model - Fixed problem for DHCP may get time out if using "Shared NIC" mode but without any LAN cable to be plugged into "Sys Mgmt" port Enhancement: - Added IPv6 support - Added Dynamic DNS support (IPv4 only) - Added support for BladeCenter PCIe Expansion 4 on BladeCenter HS22 - Added BCH-R3 support
Version 1.21, YUOO75V Enhancement: - Added support for BladeCenter Max 5 Memory Expansion Unit (MEU) - Added feature to report SMI Lane failure for BladeCenter HX5
Version 1.20, YUOO75T Enhancement: - Added support for Max 5 Memory Expansion Unit (MEU)for SystemX 3690 X5 - Added support for Max 5 Memory Expansion Unit (MEU)for BladeCenter HX5 - Added feature to show pending firmware level during firmware update process - Added feature to block power on when multi-node complex has firmware mismatch Problem(s) Fixed: - Fixed DASD LED behavior for drives 8-32 - Fixed fan over cooling on SystemX 3690 X5 - Fixed Flash failure due to packet loss - Fixed Power Cycle events not appearing in SystemX 3690 SEL - Fixed DIMM throttle behavior in acoustic mode for BladeCenter HX5 - Fixed CPU type checking
Version 1.19, YUOO75X Enhancement: - Added support for Max 5 Memory Expansion Unit (MEU)for SystemX 3850/3950 X5 - Added support for 130W CPUs in High Performance Blades - Added virtual NIC VPD support - Changed the default value of SerialExitCLIKeySequence to ^[( - Added TPM Physical Presence Sensor support - Added AC metering and capping to System x3850/3950 X5 Problem(s) Fixed: - Fixed server time out authority in web interface - Fixed non-recoverable events that appeared as warning events in web event log - Fixed Server State "unknown" status in web interface - Prevented multiple log entries from being created for the same event - Fixed IPMI multi-session handling when sessions fail - Fixed IMM flash failed at 0 percent update progress error - Fixed Internal Error 255 during FPGA update - Fixed CPU Overtemp messages on FPGA update. - Removed unnecessary events for Power Unit sensors - Fixed failure to log VRD error on voltage fault - Fixed Power Redundancy Sensor handling for 220V configurations - Fixed CPU configuration check for System x3850/3950 X5 - Fixed IMM Network ARP - Fixed flash error "Image transfer timed out - error 15" - Corrected a problem that caused the system to not automatically power on after performing an Automatic BIOS Recovery (ABR)
Version 1.18, YUOO75J Enhancement: - Added support for the System x3630 M3
Version 1.17, YUOO75H Enhancement: - Added support for the System x3690 X5
Version 1.16, YUOO73O Enhancement: - Added support for the BladeCenter System HX5
Version 1.14, YUOO73M Problem(s) Fixed: - Corrected the MIB file to address a compiling problem - Fixed a problem when a second CPU might not been recognized by the IMM, when cycling power on the System x3550 - Fixed a problem where web session may hang after staying on the System Status web page for a while - Disabled the interface to the shared network port when the dedicated systems management network interface is selected. - Fixed a web page pop-up error message that may occur after upgrading the IMM from 48d and 57f - Fixed power/thermal calibration error in the x3620 M3 - Fixed a problem where the IMM may log a CPU Automatically Throttled event or a Redundancy Lost for a cooling zone event in the log after cycling power - Fixed a problem where the IMM doesn't send an ambient temperature alert or IO Hub temperature alert in the x3400 M3 and x3500 M3 - Corrected a remote presence problem that occurs while mounting an ISO image if the remote client does not have any removable devices. Enhancement: - Added a fan control enhancement for performance mode - Added support for additional types of power supplies - Improved the accuracy of power readings on 3550 M3, 3650 M3, and 3620 M3
Version 1.14, YUOO73K (released for multinode System x3850 X5 and x3950 X5 only) Problem(s) Fixed: - Fixed a problem that caused the IMM not to respond to some IPMI commands - Corrected a problem with LDAP authentication when role-based security is enabled - Corrected a problem which could cause a false CPU error to occur - Prevented false automatic boot failure recovery events from being reported Enhancements: - Added multinode support for System x3850 X5 and System x3950 X5 - Added support to activate FPGA updates with a warm boot - Added support for AC power metering and AC power capping on single node System x3850 X5 and System x3950 X5 - Added support to improve permit early power on support - Add support to report the version information for updates that have been flashed but not yet activated - Added support to report an FPGA firmware mismatch
Version 1.12, YUOO67C Problems(s) Fixed: - Adjust the Planar VBAT voltage threshold in HS22 Enhancement: - Added support for the System x3620 M3 - Added support for DC power supplies in the System x3550 M3 and System x3650 M3
Version 1.11, YUOO56O Enhancements: - Improved ABR handling to prevent invalid ABR behavior
Version 1.10, YUOO57J (released for HS22 only) Problem(s) Fixes: - Fixed a problem where the IMM sometimes incorrectly reports a Processor 1 (CPU 1) internal error
Version 1.10, YUOO57H Problem(s) Fixed: - Made changes to improve the robustness of firmware update operations. - Corrected an LDAP authentication problem. - Corrected a problem where SNMP settings could be lost after updating the firmware. - Enable ssh by default. - Permit the Adavnced Setting Utility to enable or disable ssh. - Added support for logging a message when the blade CPU is not compatible with the chassis' blower capacity - Permit the realtime power management controller firmware to be flashed to an earlier level. - Corrected a problem that prevented the remote presence function from working with network address translation - Fixed an issue where blades would throttle/hang when chassis power supply is removed Enhancement: - Added support for the System x3550 M3, System x3650 M3, System x3500 M3, System x3400 M3, System x iDataPlex dx360 M3, and the HS22V blade - Enhanced power measurement and capping capabilities in support of xSmartEnergy control - Increased support for the number of DIMMs from 12 to 18
Version 1.09, YUOO56K Enhancement: - Added support for the System x3850 X5 and the System x3950 X5
Version 1.08, YUOO48F Problem(s) Fixed: - Made changes to improve the robustness of firmware update operations. Limitations: Limitations for versions 1.07 and 1.08: If you are down-leveling the IMM firmware to a version older than 1.07 and the IMM firmware is currently at version 1.07 or 1.08, you must remove AC power from the server before performing a server reboot.
Version 1.07, YUOO48E Prerequisites: IMPORTANT: This firmware update contains changes to permit servers ========== to be powered on sooner after plugging them into AC power. Before installing UEFI with firmware that supports the early power on changes, be sure to update the IMM with this firmware version. UEFI Firmware with early power on support: BladeCenter HS22 UEFI Build P9E131A or newer System x3550 M2 UEFI Build D6E131C or newer System x3650 M2 UEFI Build D6E131C or newer System x3200 M3 UEFI Build GYE129A or newer System x3250 M3 UEFI Build GYE129A or newer System x3400 M2 UEFI Build Y4E131B or newer System x3500 M2 UEFI Build Y4E131B or newer System x iDataplex dx360 M2 UEFI Build TME132A or newer Problem(s) Fixed: - Corrected an Ethernet bug that caused network packets to be dropped - Changed the firmware to improve server performance when the Ethernet over USB interface is enabled - Corrected an intermittent problem where some of the IMM interfaces would not function after flashing the IMM with new firmware - Corrected a problem where LDAP users in nested groups are not permitted access to the IMM - Corrected a problem where the fault LED is not lit on the HS22 server when a hard drive is removed - Fixed a problem where the IMM sometimes incorrectly reports faults when the server is power cycled (for example, a loss of redundancy or a critical fan fault, or a processor is operating in a Degraded State, etc...) - Corrected a problem where the server would sometimes hang at checkpoint 'E8' - Changed the firmware to light the Information LED if the primary UEFI bank becomes corrupted - Corrected a problem that prevented the Remote Disk on Card feature from properly working - Corrected a problem that prevented an HS22 server with a full configuration from powering on - Changed the firmware to send processor information to the Advanced Management Module for display - Corrected a problem where faults for fan numbers 2 and 4 for the System X3200 M3 were swapped - Corrected a problem where the IMM firmware could corrupt itself over time Enhancements: - Changed the firmware to permit servers to be powered on sooner after plugging them into AC power - Improved the performance when displaying pages on the web interface - Added support to permit management traffic over the daughter cards in the HS22 server
Version 1.06, YUOO39B Enhancement: - Added support for Machine Types 4251, 4252, 4261, 7327, 7328
Version 1.05, YUOO32F Limitations: Problem(s) Fixed: - This update package contains updated Management Information Base files for use when managing the server through the IMM's SNMP interface - Fixed a problem where user accounts and settings could become lost - Improved performance when changing settings through the web interface - Corrected a problem where some configuration settings were lost after flashing the IMM with new firmware - Improved the wording of messages in the Chassis Event Log - Restored the ability to the IMM SNMP interface to add or remove user accounts and to set the account security level - Corrected a problem that prevented some configuration settings from being set through the Advanced Setting Utility (ASU) - Fixed a problem that prevented a user from specifying an email alert recipient with a hyphen in the name - Fixed an IMM flash update problem where the IMM erroneously reports a CPU Configuration error and/or illuminates the fault LED on the HS22 Blade Server with no corresponding entry in the Advanced Management Module log - Fixed an IMM flash update issue which can result in blades never completing the Discovery state Enhancement: - Added support for the BladeCenter PCIe Expansion module 3 - Added support for servers running real-time Linux - Enhanced the automatic recovery of communication errors in BladeCenter - Added the ability to configure a hostname for SNMPV3 traps, rather than just an IP address
Version 1.04, YUOO24I Problem(s) Fixed: - This is a critical update for x3550 M2 and x3650 M2. It corrects a possible problem that can occur when adding options such as memory, hard drives, and Central Processing Units (CPUs), and makes the system may become unresponsive. In some cases the server cannot power on again, or network connectivity to the Integrated Management Module is not possible. The problem may also occur when rebooting the IMM while the system is powered on with certain hardware configurations. - Replaced the ibm_rndis_server_os.inf and device.cat in the IMM firmware update package for Windows. The new files are used to workaround a potential performance issue when the IMM's Ethernet over USB is enabled. Enhancement: - Added support for different hard drives - Added support that enables the Advanced Management Module to display CPU information for the HS22 blade.
Version 1.03, YUOO23C Problem(s) Fixed: - Removed the empty virtual drives that were presented to the server by default. Virtual drives are now not presented to the server unless media is present and mounted from the Remote Control client. Enhancement: - Added support for Machine Types 7836, 7837, and 7839
Version 1.02, YUOO19G Problem(s) Fixed: - Corrected a problem where a critical fan fault was erroneously logged when powering off the server
Version 1.01, YUOO19E Enhancement: - Added support for Machine Types 7946, 4198, 7947, 4199, 7321, 6380, 7323
Version 1.00, YUOO18D - Original Release - Supports Machine Types 7870, 1936
(C) Copyright International Business Machines Corporation 2008 - 2012. All rights reserved.
Firmware Version 2.01a3 (w/ 5.12a5 Universal Boot Code)
New Features
* Enhanced timeout notifications for processing abort failures.
Problems Fixed:
1. All multi-abort I/Os are returned on the same ring from which the ABORT_MXRI command was received.
2. Changed the TRCV response in the abort state to CMD RJT to enable the TRSP to be processed.
3. Corrected an issue with blocked TSEND operations.
4. Corrected a buffer leak issue with RRQ exchanges.
5. Corrected an issue where the TRCV IOCB was de-queued improperly causing a XFR_RDY flood.
6. Corrected an issue where the OXID field was not loaded in the XRI_ABORTED IOCB.
7. Corrected an issue in recognizing whether an EEPROM is present.
Dependencies: - The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly.
1. 118933 Fixed an issues booting when more than 8 ports are present in the system and fixed an adapter display issue when more than 8 ports are present in the systems 2. 118933 Fixed issues installing and booting O/Ss on ports greater than 8. 3. 121923 Fixed issues installing and booting O/Ss on ports greater than 8. 4. 122286 Fixed some boot time screen display issues.
(2) OpenBoot version 3.10a3
This version of OpenBoot supports FC-AL, Private loop, Public loop, and Fabric Point to Point. Also, it supports multi-initiators and multi-LUNs (0 through 4055)
Problems fixed, features added or other updates:
1. Unrelated to IBM
(3) EFIBoot version 4.12a12
The current EFI (Extensible Firmware Interface) Boot provides 64-bit System boot capability through the use of the EFI Shell. This EFIBoot supports EFI Specification 1.10 and EFI Source Code version 1.10.14.61.
Problems fixed, features added or other updates:
1. Only certain OEM HBAs will locate PlatformToDriverConfigurationProtocolGuid. Others just skip and continue processing 2. UEFI2.3 Hii Configuration Utility changes 3. HII Browser Save option does not work
1. CR105423 - On a port connected to a 3PAR "MBOD" cage, the test runs IO to the disk drives and issues a "controlport offline" command to offline the port while IO is running.
2. CR111194 - While doing target side cable pull testing with Block Guard (T10) Enabled we observed that adapter is not sending RSCN to AIX.
3. CR111625 - *IBM defect 775960 - HBQ ring index pointers?
5. CR111928 - 3PAR - LR with port and subsequent FLOGI failing.
Dependencies: - The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly. elx_fw_fc_ibm1206-2_01a9_linux_32-64_chg
ServeRAID M5000 Series SAS/SATA Controller Firmware Update
Version 12.12.0-0133 - Suggested ------------------- Fixes - Addressed an issue where battery over temperature messages could occur during charging. - Fixed issue in the HII broswer where the drive performing copyback will be stated as replacing and not copyback. - Fixed issue in the HII browser where the RPM for SATA drives show "0" - Fixed issue in HII browers where port 4 is shown on both ports 0 and 1 - Fixed HII browser issue where the user will get an error message when a global hot spare is created. - Fix HII browser issue where a RAID volume with greater then 3 spans will fail to create.
Version 12.12.0-0126 - Suggested ------------------- Fixes: - Fixed a issue where the RAID configuration can be lost when updating from firmware package 12.0.1-0097 or below. - Fixed an issue with 4-kilobyte (KB) sector disk support compatibility in NTFS by disabling 512E drive support mode.
Version 12.12.0-0111 - Suggested ------------------- Enhancement: - Implemented limited band charging for iBBU 07.
Fixes: - Set the compatibility bit to 1 so that Patrol reads can be executed on SSD's - Fixed an issue where EEPROM init failures are not handled properly causing the user to see the following message on POST "The native configuration is no longer supported by the current controller and firmware." - Fixed an issue where the controller fails to read the header info from CFI Flash ROM.
Version 12.12.0-0098 - Suggested ------------------- Fixes: - Fixed issue where the battery gauge is not accurate for aged batteries due to the discharge profiles of aged batteries not matching that of the new batteries. - Fixed a issue where a reboot would cause a hot spare to revert to 'Unconfigured Good' state when Performance Accelerator Key is attached. (RETAIN Tip H204925)
Version 12.12.0-0085 - Suggested ------------------- Enhancements: - Prevent non IBM firmware from being flashed on IBM ServeRAID branded controllers. - Enabled iBBU08 battery modes. - ibbu battery will no longer be marked as bad when very high capacity is detected. - Dimmer Switch function has been disabled by default.
Fixes: - Fixed a issue where firmware was taking to long to complete the PCI config read, causing the system to generate an NMI. - Fixed issue where enabling security causes the configuration to be missing, and a configured FDE array to be seen as foreign on reboot. - Removed BBU mode select from Web BIOS for all controllers. - Fixed issue where pulling VD 0 from a R60 and rebooting would cause two foreign configurations. - Fixed issue where WebBIOS gives unclear message when enabling FDE on an existing Disk Group. - Fixed issue where iBBU07 batteries display 65K capacity and are marked SOH bad. - Fixed issue where iBBU Absolute Charge is displayed differently - Fixed issue where the logical Unit ID (VPD page 0x83) changed after foreign import. - Fixed issue where the LDBBM entries are incorrect after foreign import. - Fixed issue where the controller does not work with pci set to nomsi in kdump kernel. - Fixed issue where the LED behavior is incorrect, wrong drive will blink activity. - Fixed issue where the controller cannot sustain at least 950 MBps performance with Cache Flush setting one sec. - Fixed issue where the set properties command fails - Fixed issue where the iBBU07 battery reported remaining capacity is much too high (64751 mAh) after a learn cycle. - Fixed issue where extended retries of write verify commands cause a driver timeout. - Fixed issue where the configuration becomes foreign after the firmware fails multiple attempts to access raid key during boot. - Fixed firmware issue where a replacement drive is not seen if the replacement is added during power cycle. - Fixed a issue where an alert should be sent when one phy connector between the SAS controller and SAS expander is degraded. - Enabled puncturing for SATA drives. - Enabled copy back on SMART. - Fixed an intermittent RAID key failure during power-on. - Fixed firmware issue where firmware would cause the controller to (sles11sp1/rhel6) reset when ‘lspci –vvx’ command is executed. - Change for iBBU-08 to support firmware Mode5 WB capacity from 960mAh to 674mAh for low power DDR-2 - Fixed a issue where the iBBU battery will not charge while the server continually resets causing the iBBU battery to over-charge.
Version 12.12.0-0065 - Critical ------------------- Fixes: - Fixed issue where the firmware takes too long to complete a PCI Config Read cycle causing SLES11 to kernel panic. - Fixed issue where MegaCLI may not be able to change drive or controller cache setting resulting in a return code of 0x03. - Added check to return SCSI sense Check condition if PMI is set and LBA is non Zero for SCSI Read Cap 16 - Fixed issue where a blue screen occurs handling RAID 1 with HSP and medium errors. The blue screen occurs because the driver times out while the firmware is retrying sense 0x02. Firmware causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR - Change the boot with pinned cache RAID level support which was only allowed for raid level 0. The check is removed and is allowed for any raid level. - Fixed hang condition or condition where the uEFI driver does not load due to the uEFI Driver issuing a command in poll mode to firmware to early - Remove the following message "Battery cannot initiate transparent learn cycles" when the iBBU08 is under mode 4 or 5 - Fixed issue where BGI will not disable when a user issues megacli -LDBI -Dsbl -L0 -a0
Version 12.12.0-0056 - Critical ------------------- Fixes - Fixed issue where multi-bit ECC's are not reported during POST - Lowered the capacity level at which event notifications are generated for early warning and end of life alerts for iBBU to equal 48 hours
Version 12.12.0-0047 - Critical ------------------- Fixes: - Fixed issue where uEFI WebBIOS version may not display the product name of the second controller - Fixed issue to prevent users from downleveling firmware to older versions - Fixed an issue where firmware reports "Unexpected sense, Invalid field in CDB" for LOG SENSE command sent to Seagate drives - Fixed issue where SMART failures can take longer then 5 minutes to report or in some cases fail to report - Fixed issue where it appears to the user the harddrive cache policy is changed when requested but the change did not occur - Fixed issue where a remote iBBU08 will not be seen by the controller - Fixed data issue When IO is in progress to a RAID 1 array that contains media errors and is under a rebuild - Fixed issue where a drive is not marked as foreign during a drive move between servers causing the import of the configuration to fail - Fixed issue where the uEFI WebBIOS does not accept the + symbol in the key code or pass phrase - Fixed issue for iBBU08
Enhancement: - Enhancement to Reserve/release call for VCS Symantec configurations - Enhancements to iBBU event notifications, including the addition of early warning message. - Raised the capacity level at which event notifications are generated for early warning and end of life alerts for iBBUs
Version 12.12.0-0039 - Critical ------------------- Fixes: - Fixed intermittent initialization failure during POST with the ServeRAID M5025, M5015, and M5014 where the RAID BIOS could fail to load or the user will see one of the following error messages on POST:
RAID Adapter Unrecoverable Error!!! Please check the SDRAM connection.
or
Multi-bit ECC errors were detected on the RAID controller
Version 12.12.0-0037 - Critical ------------------- Enhancement: - Add support for iBBU08 (Battery Backup)
Fixes: - Addressed data issue while reconstructing from RAID1 to RAID0. - Addressed data issue after power lose to ServeRAID controllers. - Addressed data issue in some database applications. - Added fixes from LSI channel products.
Version 12.7.0-0020 - Critical ------------------- Enhancement: - Initial release for ServeRAID M5025 SAS/SATA Controller (46M0830)
Fixes: - Addressed data issue with database applications that use overlapping read write operating. - Addressed data issue which may occur during a reconstruction on some RAID levels that have an associated CacheCade virtual drive enabled. - Fixed issue where the controller may halt if a drive has medium errors that are being used in a check consistency, patrol read, or have delayed writes.
Version 12.0.1-0097 - Critical ------------------- Fixes: - Addresses an issue where data becomes inaccessible when drive is secured after data has been written . Version 12.0.1-0096 - Critical ------------------- Fixes: - Fixed an issue where the BBU may not be seen on POST. - Fixed an issue where the firmware doesn't follow the spinupdelay and maxtargetspinup values set in NVDATA causing spin up of all the drives a at the same time. - Fixed a very intermittent issue where the RAID key (M5000) authentication may not occur on boot leaving users without key options. - Addressed a very rare issue with the expander devices where the firmware megamon could occur if the sgpio configuration cable has errors.
Version 12.0.1-0090 - critical ------------------- Fixes: - Fixed issue where controller properties such as Rebuild, CC, and BGI are not changing when up and down arrow keys are used. - Fixed issue on x3950 M3 servers that can cause a system hang at reboot
Version 12.0.1-0084 - Non-critical ------------------- Enhancement: - Support added for the ServeRAID M5000 Series Advanced Feature Key.
Version 12.0.1-0064 ------------------- - Initial release ibm_fw_sraidmr_m5000-12_12_0-0133_linux_32-64_chg
ServeRAID m5016 SAS/SATA Controller Firmware Update for Windows
Adapters Supported: ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304)
NOTE TO SERVICE - Reference RETAIN #N/A
Version 23.7.1-0009 - Suggested ------------------- Fixes: - Fixed an issue where SoH is bad after a learn cycle but iBBUI shows good status. - Fixed an issue where hi-temp warning was not being displayed.
Version 23.7.1-0004 - Suggested ------------------- Fixes: - Corrected differential signals for Phys 2 and 3 that caused slot numbers in simple swap configurations to be wrong. - Fixed an issue when “maintain PD Failed history” is enabled, a cable is removed and added drives states go to optimal instead of foreign unconfig bad. - Fixed an issue where a capacity change is reported after a rebuild completes on a cache. - Fixed a controller firmware hang when the recovery of a medium error takes to long. - Fixed an issue where the SATA BBM (Bad block manager) list was getting corrupted as the logic was not accounting for a boundary condition of zero. - Fixed an issue where FoD (Feature on Demond) Options are lost because of errors while accessing the TSOC - Fixed an issue where the controller firmware will crash and drives will go offline when a bad block entry is created during a check consistency operation. - Fixed an issue where drives marked as unconfigured bad (foreign) gets marked as unconfigured bad on reboot - Fixed problem where a drive member of a cache cade volume does not get marked as foreign when the drive is pulled with maintain PD history enabled. - Fixed an issue where during a reboot a former hotspare which was in a state of unconfigured good moves to the state hot spare automatically and copy back stops causing the rebuild to start again. - Fixed an issue where a controller fault occurs when a reboot happens while a physical device is in progress of a PD Erase.
Version 23.7.0-0029 - Suggested ------------------- Enhancements: - Added support for Cache Cade 2.1 - Added Support for PI Drives
Fixes: - Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup. - Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive - Added a check for the presence of PD before writing the data arms of a protected LD during BGI. - Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS. - Fixed an issue with USB Cacheoffload restore fails after multiple power cycles on ServeRAID M51xx controllers. - Fixed an issue where querying SMART / PFA Status returns ‘all zeros’ in Sense Data. - Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash. - Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds. - Fixed background initialization watermark conversion to PD LBA. - Fixed write protected R1E data arms during initialization. - Fixed an issue where MR firmware crashed while discarding pinned cache. - Fixed an issue where a dirty LD dependency information of SSD pd has stale entries. - Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd - Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset. - Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe. - Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM. - Fixed an issue where the firmware was wrongly adding puncture entries. - Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table. - Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event. - Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events. - Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled. - Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value. - Fixed an issue in which a Patrol Read may not start under certain conditions. - Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved. - Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero. - Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU. - Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed. - Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running. - Fixed an issue where CC stops progressing on a R6 VD with media errors. - Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test). - Fixed an issue where controller features are lost if RAID Key was not detected - Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering. - Fixed an issue where ‘Native configuration is no longer supported’ message in post. - Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low. - Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Version 23.2.1-0043 - Suggested ------------------- Fixes: - Fixed an issue where "Potential non-optimal configuration due to drive PD commissioned as emergency spare" alarm would trigger erroneously. - Fixed an issue where Copyback does not progress upon inserting drives. - Fixed an issue When allowMixInLD is Disabled, and causes Copyback Fails after Rebuild to Emergency Hot Spare. - Fixed an issue where the Firmware faults while flashing. - Fixed the Querying SMART / PFA Status to Return All Zeros in Sense Data. - Fixed an issue where the Re-inserted Drives becomes Unconfigured_good causing auto rebuilds to fail to start.
Version 23.2.1-0021-01 Non-Critical ------------------- - Packaging fix only to resolve flash failure. Note: Firmware version has not changed.
Version 23.2.1-0021 ------------------- - Initial release ibm_fw_sraidmr_m5016-23_7_1-0009_linux_32-64_chg
BIOS/FW/UEFI Update for ServeRAID H1110 SAS/SATA Controller for IBM System x
Controller Supported: ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492)
Fixes: - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal. - Fixed issue where update will not install with the 09.101 megaraid_sas device driver.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function. - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support.
- HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
IBM ServeRAID MR10i and MR10is SAS Controller Firmware Update
Adapters Supported: IBM ServeRAID MR10i SAS Controller (43W4296) IBM ServeRAID MR10is SAS Controller (44E8695)
NOTE TO SERVICE - Reference RETAIN #NA
Version 11.0.1-0042 - Critical ------------------- Enhancements: Adjust various battery parameters and alerts to improve product - Reword the battery ‘Prefail‚ and ‘Fail‚ Alerts and all places it is documented - Add visibility of ‘battery nearing end of usable life‚ condition to CLI and MSM - Adjust parameters used to calculate battery capacity amount for Early Warning and EOL alerts
Fixes - Fixed issue where While correcting massive UNC sectors, I/O will be interrupted causing OS becomes unusable - Fixed issue where SPD Data can get Corrupted on Boot causing the following message on boot the message displayed is "Check SDRAM Connection". - Fixed issue where firmware has Incompleted Writes During Power Fail and Recovery causing the following message on boot "Controller cache discarded due to memory/battery problems
Version 11.0.1-0040 - Critical ------------------- Fixes: - Fixed an issue that was contributing to early fallout with battery packs. - Fixed an issue that was causing a loss of battery capacity. - Fixed an issue where the gas gauge was reporting capacity of 65000+mAh and then marking battery as SOH bad. - Fixed issue where multiple reboots were required after a new battery was inserted in a controller. - Fixed issue where T95: VT#00560-T95386=Battery cannot support data retention for more than 59 hours. Please replace the battery. When battery logic generates the event MR_EVT_BBU_REPLACEMENT_NEEDED_SOH_NOT_OPTIMAL, the FW prints the error, T95: EVT#00538-T95: 386=Unknown ARG type=24, code=182.
- Changed post message from
RAID ADAPTER Memory Error !!! Please check the SDRAM connection. If problems persist contact Tech Support. Press Any Key to Continue…
to
Check the SDRAM connection, if applicable, or replace the controller."
Version 11.0.1-0036 - Critical ------------------- Enhancements - BBU AEN enhancements
Fixes: - Fixed issue where firwmare fault could occur when a hot spare drive responds with Sense 0x02 for Write/Verify. - Fixed issue where a firwmare fault could occur when consecutive Medium Errors are found in Degraded SATA RAID5, 6 state
Version 11.0.1-0033 - Critical ------------------- Fixes: - Fixed issue where SATA hard drive write cache could be enabled on a drive insert or system reboot.
Version 11.0.1-0032 - Critical ------------------- Fixes: - Modified memory settings for the ServeRAID MR10k that where not optimal for the controller causing memory failues.
Version 11.0.1-0031 - Critical ------------------- Fixes: - Addressed an issue where a physical drive with an excessive amount of medium errors will cause the array to fail
Version 11.0.1-0030 - Critical ------------------- Fixes: - Leaving array size field blank during array creation to resolve issue where raid level would change but array size did not change with the level. Retain tip H196863. - Fixed issue where the Cursor movement is not proper while entering Security Key/PassPhrase in EFI WebBIOS environment - Fixed issue where the Visibility of webbios version doing controller selection is not there - Address compatabilty issue with uEFI WebBIOS in the x3850 x5 and HS22 x5 - Fixed issue where a fatal FW Error happens during Consistency Check operation while a patrol read is in progress.
Version 11.0.1-0024 - Critical ------------------- NOTE TO SERVICE - H196421, H196426, H196374 Fixes: - Fixed issue with Firmware Hang (Fatal Error) when drive responds with Sense 0x02 for Test Unit Ready Command. - Fixed an issue where the ServeRAID-MR10ie (CIOv) battery fault indicator never clears - Added limit to quantity of consecutive relearn cycles to cache battery unit - Fixed issue where the Pass phrase can not be entered on the ServeRAID MR10is controller - Fixed issue where the user cannot enter the uEFI WebBIOS or system will hang on boot
Version 11.0.1-0022 - Critical ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where systems that use DL_DOWN instead of (or in addition to) PCI reset exhibit 1800 PCI ERROR. - Fixed an issue where a non-responsive disk caused fatal firmware error - Fixed an issue with write journaling - Fixed an issue with READ XOR logic in RAID1 special operations
Functionality: - Added support for dynamically toggling readjustment of PCIe maximum read request size
Version 11.0.1-0019 - Critical ------------------- NOTE TO SERVICE - No current tips Fixes: - Addressed an issue in x3550 M2 and x3650 M2 where the slot numbers could change on a cold reboot.
Version 11.0.1-0017 - Suggested ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where, on shudown, firmware was not sending a command for the drive to flush its internal cache. - Removed I/O delay during device firmware update for non-disk devices. - Added check for additional error data from mode sense command.
Functionality: - Added pass through command support for applications.
Version 11.0.1-0014 - Critical ------------------- NOTE TO SERVICE - Reference RETAIN #H194939 Fixes: - Addressed an issue where, during I/O and manual copyback on a degraded RAID 6 virtual drive with medium errors, incorrect data could be created on the drive. - Fixed an issue where, on the ServeRAID 10ie (CIOv), a new or changed battery installation was not detected on the iBBU. - Fixed an issue where SATA drives may not be detected at POST when attached to an expander. (Retain tip H194939) - Addressed an issue where the controller may hang if a medium error occurs during a rebuild. - Fixed an issue where cache data could be lost during a reset after the express link is dropped. - Addressed an issue where a consistency check doesn't regenerate parity after hitting a double media error. - Fixed an issue where the uEFI WebBIOS can hang if the user presses the right mouse button when user input is not required. - Addressed an issue where an invalid memory or battery error is reported on boot, but does not reappear on a subsequent boot.
Version 11.0.1-0012 - Suggested ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where, rarely, cached data may be lost on system shutdown or reboot.
Version 11.0.1-0008 - Critical ------------------- NOTE TO SERVICE - Reference RETAIN #H194224, H194505, H194171 Fixes: - Fixed an issue which could result in incorrect data on the drives after heavy I/O. (Retain tip H194224) - Fixed an issue where, if medium errors are experienced while a background operation is running, incorrect data could be written to the drives. (Retain tip H194505) - Changed the warning message that appears when the card goes in to temporary write through mode. (Retain tip H194171) - Fixed an error where erroneous Bad Battery messages were displayed even after a Learn Cycle was performed. - Fixed an issue that resulted in SERRs on a ServeRAID-MR10M controller. - Improved the handling of bad cable scenarios which could cause system hangs.
Functionality: - Added support for UEFI based systems. - Added support for Solid State Drives (SSDs). - Added tape support for the ServeRAID 10ie (CIOv) controller. - Added the ability to handle SGPIO and SES signalling on a per-port basis to handle configurations with both direct attached and expander attached drives on a single controller. - Added a field to show hard drive model names in WebBIOS.
Version 9.0.1-0030 - Critical ------------------ Fixes: - Fixed an issue where, if a battery was fully discharged and was reported as 'missing', a reboot was be required before the battery would be detected as 'charging'. - Fixed an issue where a hotspare was reported as unconfirmed good after replacement. - Fixed an issue where an invalid alert 2121 was logged when a virtual drive was created. - Display and log a warning message when a consistency check is started on an uninitialized logical drive. - Fixed an issue where the message "SES enclosure 1 Recovered after fault" would be logged, after which the discovery process would take a very long time. - Fixed an issue where the multipath enclosure IDs were not updated correctly when an ESM or a drive was pulled and reinserted. - Fixed an issue where, if a unconfigured drive was pulled and reinserted, the size of the drive would be reported incorrectly. - Fixed an issue where a dedicated hotspare would become a global hotspare. This could happen after a migration or, in some circumstances, after a system reboot. - Fixed an issue where the firmware could hang when trying to view hotspare information under CTRL-R. - Fixed an issue where a rebuild would not start when a new drive was inserted. - Fixed an issue where a logical drive is still shown as optimal after a drive was pulled. - Fixed a critical firmware error that occurred when a physical drive was pulled from a RAID10 or RAID1E during heavy I/O. - Fixed an issue where a hang could occur when an ESM was removed. - Fixed an issue where, if multiple physical drives are pulled from an enclosure, additional drives might be lost. This could lead to incorrect data on the disks. - Fixed an issue where reconfiguring a virtual disk by adding a drive, or similar activity, will cause a dedicated hotspare to become unassociated. - Fixed an issue where a success code was incorrectly returned when data was sent to a failed drive. This could cause a loss of data. - Fixed an issue where, if additional drives failed in a virtual disk while a rebuild was happening, the system could hang. - Fixed an issue where daisy-chained enclosures would all be reported with the same position number. Also fixed a related issue where 'locate' did not function properly for daisy-chained enclosures. - Fixed an issue where the controller could hang if diagnostics were run while a rebuild was happening. - Fixed an issue where hotspares were lost during configuration import. - Fixed an issue where, if two enclosures were configured and the cable was pulled from each, then reattached in a swapped configuration, the system would hang on boot. - Fixed an issue where successive power cycles in a multi-enclosure configuration could result in offline drives or a system hang. - Fixed an issue where, with the controller mux set to 'Auto', configuration would be lost during reboot. - Fixed an issue where rebuilds might fail to resume after enclosure power is restored. - Corrected several issue where the consistency check was not properly handling double medium errors. - Ensured that BGI (Background Initialization) setting was retained during foreign configuration import. - Fixed an issue which caused MSM to not allow creation of additional virtual disks once 16 virtual disks existed. - Fixed an issue that caused a hang if a rebuild was in progress when a configuration was migrated from an IR to an MR controller. - Fixed an issue where load balancing would not resume properly after a cable pull. - Fixed an issue where, during a target or chip reset, the Disk Write Cache setting on a SATA drive would be reset to default, which is generally 'enabled'. - Fixed an issue where, when BGI is aborted, the status for the CC (consistency check), rather than the status for the BGI, is reported. - Fixed an issue where, if a physical disk fails, causing a logical drive to become degraded, trying to clear or change the configuration would result in a hang until the failed drive was physically removed. - Fixed a hang that was seen when a cable was pulled just before system shutdown. - Ensured that a hotspare would revert back to hotspare state after a rebuild to that hotspare failed. - Fixed several issue that could cause "Illegal Request Sense Data" messages. - Fixed an issue where a rebuild would hang if one of the logical drives on the array was deleted during the rebuild. - Fixed an issue which could result in incorrect data in a scenario where RAID 50 arrays are running in a degraded state for an extended period of time. - Fixed several issues where medium errors could result in offline drives, incorrect data on drives, failed rebuilds, or system hangs. - Fixed an issue where, when a redundant path in a multipath system fails, some drives are marked offline. - Fixed an issue which could cause hangs when replacing a controller with an existing configuration. - Fixed several grammatical and formatting issues. - Fixed an issue where importing foreign configuration under CTRL-R could cause the firmware to crash. - Fixed an issue where an unresponsive SEP could result in a "greater than 122 devices detected" message. - Fixed an issue where the, after a RAID 6 is reconstructed as a RAID 5, the configuration is reported incorrectly upon reboot. - Fixed an issue which could result in incorrect data on the drives when I/O is run while a capacity expansion is in progress. - Fixed an issue that could cause a hang when an enclosure is power cycled while I/O is running. - Fixed an issue where, if a physical drive became invalid during a rebuild to that drive, the rebuild would pause, rather than fail. - Fixed an issue where Battery Warning messages would appear, even when disabled. - Fixed an issue which resulted in "Unexpected sense" messages in the log with SATA drives. - Fixed an issue where Cache Data could be lost during a power failure. - Fixed an issue where not all SATA drives were found during discovery. - Fixed an issue which may result in a firmware hang during a reconstruction operation. - Fixed an issue where the firmware would continue to try to communicate with a bad drive. The symptom of this issue is a drive where the status light is blinking amber and the activity light is solid green. - Fixed an issue where an enclosure reboot could, very rarely, cause a condition where the driver sends a Kill Adapter signal. - Fixed an issue where, if a medium error is encountered on a source drive during a rebuild, the bad block may not get marked as bad. - Fixed an issue where running in degraded mode with medium errors could cause the firmware to hang. - Fixed an issue where running heavy I/O on daisy-chained enclosures for an extended period of time could cause a hang. - Fixed an issue where, with some hardware, the configuration is not found within the timeout time on a cold reboot. This leads to a prompt to import configuration, after which, the configuration is seen correctly. - Fixed an issue with I2C LED support. - Fixed an issue where the write cache policy would unexpectedly change from write back to write through, then would change back after about a minute. - Fixed an issue where, if a cable is pulled in a multipath environment, the alternate path is sometimes not followed. - Fixed an error in the ECC error logging which can cause a memory leakage. - Fixed an issue where the firmware will hang if discovery does not complete in two minutes. - Fixed an issue where full initialization of a large number of SATA drives would cause timeouts. - Fixed several LED issues with I2C backplanes. - Fixed an issue sensing dual I2C backplanes in a multipath environment.
Functionality: - Added support for 64 virtual disks per array. - Added support for expanded RAID 1, a form of RAID 1E which supports even numbers of drives. - Added the ability to hot-swap a battery. - Added the ability to manually initiate the battery learn cycle. - Added multipathing support for SATA drives. - Added the ability to enable or disable NCQ from the CLI or WebBIOS. - Added the copyback feature, which is used when a drive goes defunct and the array rebuilds to a hotspare. Copyback allows the hotspare to rebuild to a new drive that is inserted to replace the defunct drive. - Clarified several log event messages. - Implemented load balancing when multipath SAS is used. - Added logging for some events that were not previously logged. - Increased the PHY count from 512 to 640 to support 21 enclosures.
Version 8.0.1-0036 - Non-critical ------------------ Fixes: - Address issue where SATA drives attached to an expander will not respond in a specific time period causing the drives to be seen as foreign. - Add support for the IBM ServeRAID 10il SAS/SATA adapter.
Version 8.0.1-0033 - Suggested ------------------ Fixes: - Fixed issue where current write policy is not changed to write back even if iBBU completes the charging in 1078 HWR. - Fixed an issue where the firmware reports "MonTask: line 3566 in file ../../raid/1078dma.c" while running reconstruction on a degraded logical drive and injecting media errors. - Fixed an issue where a controller would hang during a reboot. - Fix is done to invalidate the parity cache for the punctured block before releasing the cache line - Fix for WebBIOS hangs with greater then 5 MegaRAID adapters installed.
Version 8.0.1-0029 - Critical ------------------ Fixes: - Fixed an issue where, while performing I/O during a RAID level migration or an array capacity expansion, incorrect data may be passed during a data transfer.
Version 8.0.1-0027 - Critical ------------------ Fixes: - Implemented changes to ensure the firmware does not violate the DDR2 spec during the initialization sequence in a 1078 ROMB environment. - Fixed an issue where the controller enters MegaMon when a rebuilding span is removed. - Fixed an issue where the operating system may crash after an S3 resume followed by a manual restart. - Fixed an issue where a bad SAS cable, connected between two enclosures, could cause the firmware on the associated controller to crash. - Fixed a chip reset that could happen during boot sequence of RHEL 5 64-bit. - Fixed an issue where WebBIOS does not initially see external devices, and, if RAID is configured, the “missing config” prompt is shown in the BIOS. This was caused by the firmware not waiting for the second discovery attempt that is necessary to find external devices. - Fixed an issue where, on a 1078 chip, firmware was not properly marking a drive dead. Consequently, a write to that drive would appear to complete successfully, but would actually fail, therefore the data could be incorrect. - Fixed an issue where, under heavy load, with write back enabled, the following error was seen: "ERROR: Stale read check failure. Page image returned does not match previous write. Check hardware and caches. Read size was 16384" - Fixed an issue where import of foreign drive configuration would fail. - Fixed an issue where firmware could crash when a large number of hard drives is connected to a ServeRAID MR10M. - Fixed an issue where multiple reboots of cascading enclosures could result in incorrect data. - Fixed an issue where the Global Hard Drive Summary LED was not working. - Disallowed the addition of logical drives in an array that is being rebuilt. This fixes an issue where a newly created logical drive on a rebuilding array would be deleted on reboot. - Fixed an issue where the drive sizes were shown incorrectly after drive migration in an array with two or more different sized drives. - Fixed an issue where the source drive in a rebuild would be failed after several ECC errors.
Functionality: - Implemented Slot ID mapping support in a mixed topology. - Implemented a performance enhancement for sequential read workloads. - Reenabled offline hard drive firmware flash. Now hard drive firmware can be flashed in either an online or an offline state. - Implemented a new event so that dirty cache will be discarded on a virtual drive that is missing or offline.
Version 8.0.1-0021 ------------------ - Initial release ibm_fw_sraidmr_10i-10is-11_0_1-0042_linux_32-64_chg
Firmware Update for ServeRAID B5015 SSD Controller
- Fixed issue where the operating system's filesystem goes read only or adapter becomes non-responsive to management tools due to a resource leak in device flush path
- Addressed issue where a device timeouts may occur due to NCQ error handling did not confirm a request had completed successfully (including residual count) after a drive is removed and before using buffer contents. These contents include the failing tag, error status, and, in the case of an ECC error, a failing LBA.
- Fixed issue where the the controller may hangs due to a drive timeout during a hot drive pull.
- Fixed issue where a user may continuously pull, reinsert the drive and initiate rebuilds numerous times resulting in a read command to fail that should of completed.
ServeRAID M and MR10 Series SAS Controller Driver for Linux (also supports MegaRAID 8480 SAS Controller)
Adapters Supported: - ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481) - ServeRAID M5110e SAS/SATA Controller for IBM System x - ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478) - ServeRAID M5025 SAS/SATA controller (46M0830) - ServeRAID M5016 SAS/SATA Controller for IBM System x (90Y4304) - ServeRAID M5015 SAS/SATA controller (46M0829) - ServeRAID M5014 SAS/SATA controller (46M0916) - ServeRAID M1015 SAS/SATA Controller (46M0831) - IBM ServeRAID MR10il SAS controller (44E8767) - IBM ServeRAID MR10is SAS controller (44E8695) - IBM ServeRAID MR10ie (CIOv) SAS controller (46C7167) - IBM ServeRAID MR10i SAS controller (43W4296) - IBM ServeRAID MR10k SAS controller (43W4280) - IBM ServeRAID MR10M SAS controller (43W4339) - MegaRAID 8480 SAS controller (39R8850)
Version 00.00.06.19 - Suggested ------------------- Enhancements: - Add support for RedHat Enterprise Linux (RHEL) 6.3.
Fixes: - Fixed an issue where a kernel crash may occur in some cases, when megaraid_sas driver is loaded but controller is not present.
Version 00.00.06.15 - Suggested ------------------- Enhancements: - Add support for fpRead/WriteCapable & fpRead/WriteAcrossStripe - Add support for RedHat Enterprise Linux (RHEL) 6.2.
Fixes: - Mask off MFI_FRAME_IEEE, MFI_FRAME_SGL64, MFI_FRAME_SENSE64 in megasas_mgmt_fw_ioctl() to prevent memory scribble issues from incorrectly built MegaCli frames. - Fixed reglockFlags for degraded RAID 5/6.
Version 00.00.06.12-01 - Non Critical ------------------- Fix: - Packaging fix only to remove "sh: line 1: .conf: command not found" message.
Version 00.00.06.12 - Initial release ------------------- ibm_dd_sraidmr_00_00_06_19_rhel6_32-64_chg
IBM ServeRAID MR10M SAS Controller Firmware Update
Adapters Supported: IBM ServeRAID MR10M SAS Controller (43W4339)
NOTE TO SERVICE - Reference RETAIN #NA
Version 11.0.1-0042 - Critical ------------------- Enhancements: Adjust various battery parameters and alerts to improve product - Reword the battery ‘Prefail‚ and ‘Fail‚ Alerts and all places it is documented - Add visibility of ‘battery nearing end of usable life‚ condition to CLI and MSM - Adjust parameters used to calculate battery capacity amount for Early Warning and EOL alerts
Fixes - Fixed issue where While correcting massive UNC sectors, I/O will be interrupted causing OS becomes unusable - Fixed issue where SPD Data can get Corrupted on Boot causing the following message on boot the message displayed is "Check SDRAM Connection". - Fixed issue where firmware has Incompleted Writes During Power Fail and Recovery causing the following message on boot "Controller cache discarded due to memory/battery problems
Version 11.0.1-0040 - Critical ------------------- Fixes: - Fixed an issue that was contributing to early fallout with battery packs. - Fixed an issue that was causing a loss of battery capacity. - Fixed an issue where the gas gauge was reporting capacity of 65000+mAh and then marking battery as SOH bad. - Fixed issue where multiple reboots were required after a new battery was inserted in a controller. - Fixed issue where T95: VT#00560-T95386=Battery cannot support data retention for more than 59 hours. Please replace the battery. When battery logic generates the event MR_EVT_BBU_REPLACEMENT_NEEDED_SOH_NOT_OPTIMAL, the FW prints the error, T95: EVT#00538-T95: 386=Unknown ARG type=24, code=182.
- Changed post message from
RAID ADAPTER Memory Error !!! Please check the SDRAM connection. If problems persist contact Tech Support. Press Any Key to Continue…
to
Check the SDRAM connection, if applicable, or replace the controller."
Version 11.0.1-0036 - Critical ------------------- Enhancements - BBU AEN enhancements
Fixes: - Fixed issue where firwmare fault could occur when a hot spare drive responds with Sense 0x02 for Write/Verify. - Fixed issue where a firwmare fault could occur when consecutive Medium Errors are found in Degraded SATA RAID5, 6 state
Version 11.0.1-0033 - Critical ------------------- Fixes: - Fixed issue where SATA hard drive write cache could be enabled on a drive insert or system reboot.
Version 11.0.1-0032 - Critical ------------------- Fixes: - Modified memory settings for the ServeRAID MR10k that where not optimal for the controller causing memory failues.
Version 11.0.1-0031 - Critical ------------------- Fixes: - Addressed an issue where a physical drive with an excessive amount of medium errors will cause the array to fail
Version 11.0.1-0030 - Critical ------------------- Fixes: - Leaving array size field blank during array creation to resolve issue where raid level would change but array size did not change with the level. Retain tip H196863. - Fixed issue where the Cursor movement is not proper while entering Security Key/PassPhrase in EFI WebBIOS environment - Fixed issue where the Visibility of webbios version doing controller selection is not there - Address compatabilty issue with uEFI WebBIOS in the x3850 x5 and HS22 x5 - Fixed issue where a fatal FW Error happens during Consistency Check operation while a patrol read is in progress.
Version 11.0.1-0024 - Critical ------------------- NOTE TO SERVICE - H196421, H196426, H196374 Fixes: - Fixed issue with Firmware Hang (Fatal Error) when drive responds with Sense 0x02 for Test Unit Ready Command. - Fixed an issue where the ServeRAID-MR10ie (CIOv) battery fault indicator never clears - Added limit to quantity of consecutive relearn cycles to cache battery unit - Fixed issue where the Pass phrase can not be entered on the ServeRAID MR10is controller - Fixed issue where the user cannot enter the uEFI WebBIOS or system will hang on boot
Version 11.0.1-0022 - Critical ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where systems that use DL_DOWN instead of (or in addition to) PCI reset exhibit 1800 PCI ERROR. - Fixed an issue where a non-responsive disk caused fatal firmware error - Fixed an issue with write journaling - Fixed an issue with READ XOR logic in RAID1 special operations
Functionality: - Added support for dynamically toggling readjustment of PCIe maximum read request size
Version 11.0.1-0017 - Suggested ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where, on shudown, firmware was not sending a command for the drive to flush its internal cache. - Removed I/O delay during device firmware update for non-disk devices. - Added check for additional error data from mode sense command.
Functionality: - Added pass through command support for applications.
Version 11.0.1-0014 - Critical ------------------- NOTE TO SERVICE - Reference RETAIN #H194939 Fixes: - Addressed an issue where, during I/O and manual copyback on a degraded RAID 6 virtual drive with medium errors, incorrect data could be created on the drive. - Fixed an issue where, on the ServeRAID 10ie (CIOv), a new or changed battery installation was not detected on the iBBU. - Fixed an issue where SATA drives may not be detected at POST when attached to an expander. (Retain tip H194939) - Addressed an issue where the controller may hang if a medium error occurs during a rebuild. - Fixed an issue where cache data could be lost during a reset after the express link is dropped. - Addressed an issue where a consistency check doesn't regenerate parity after hitting a double media error. - Fixed an issue where the uEFI WebBIOS can hang if the user presses the right mouse button when user input is not required. - Addressed an issue where an invalid memory or battery error is reported on boot, but does not reappear on a subsequent boot.
Version 11.0.1-0012 - Suggested ------------------- NOTE TO SERVICE - No current tips Fixes: - Fixed an issue where, rarely, cached data may be lost on system shutdown or reboot.
Version 11.0.1-0008 - Critical ------------------- NOTE TO SERVICE - Reference RETAIN #H194224, H194505, H194171 Fixes: - Fixed an issue which could result in incorrect data on the drives after heavy I/O. (Retain tip H194224) - Fixed an issue where, if medium errors are experienced while a background operation is running, incorrect data could be written to the drives. (Retain tip H194505) - Changed the warning message that appears when the card goes in to temporary write through mode. (Retain tip H194171) - Fixed an error where erroneous Bad Battery messages were displayed even after a Learn Cycle was performed. - Fixed an issue that resulted in SERRs on a ServeRAID-MR10M controller. - Improved the handling of bad cable scenarios which could cause system hangs.
Functionality: - Added support for UEFI based systems. - Added support for Solid State Drives (SSDs). - Added tape support for the ServeRAID 10ie (CIOv) controller. - Added the ability to handle SGPIO and SES signalling on a per-port basis to handle configurations with both direct attached and expander attached drives on a single controller. - Added a field to show hard drive model names in WebBIOS.
Version 9.0.1-0030 - Critical ------------------ Fixes: - Fixed an issue where, if a battery was fully discharged and was reported as 'missing', a reboot was be required before the battery would be detected as 'charging'. - Fixed an issue where a hotspare was reported as unconfirmed good after replacement. - Fixed an issue where an invalid alert 2121 was logged when a virtual drive was created. - Display and log a warning message when a consistency check is started on an uninitialized logical drive. - Fixed an issue where the message "SES enclosure 1 Recovered after fault" would be logged, after which the discovery process would take a very long time. - Fixed an issue where the multipath enclosure IDs were not updated correctly when an ESM or a drive was pulled and reinserted. - Fixed an issue where, if a unconfigured drive was pulled and reinserted, the size of the drive would be reported incorrectly. - Fixed an issue where a dedicated hotspare would become a global hotspare. This could happen after a migration or, in some circumstances, after a system reboot. - Fixed an issue where the firmware could hang when trying to view hotspare information under CTRL-R. - Fixed an issue where a rebuild would not start when a new drive was inserted. - Fixed an issue where a logical drive is still shown as optimal after a drive was pulled. - Fixed a critical firmware error that occurred when a physical drive was pulled from a RAID10 or RAID1E during heavy I/O. - Fixed an issue where a hang could occur when an ESM was removed. - Fixed an issue where, if multiple physical drives are pulled from an enclosure, additional drives might be lost. This could lead to incorrect data on the disks. - Fixed an issue where reconfiguring a virtual disk by adding a drive, or similar activity, will cause a dedicated hotspare to become unassociated. - Fixed an issue where a success code was incorrectly returned when data was sent to a failed drive. This could cause a loss of data. - Fixed an issue where, if additional drives failed in a virtual disk while a rebuild was happening, the system could hang. - Fixed an issue where daisy-chained enclosures would all be reported with the same position number. Also fixed a related issue where 'locate' did not function properly for daisy-chained enclosures. - Fixed an issue where the controller could hang if diagnostics were run while a rebuild was happening. - Fixed an issue where hotspares were lost during configuration import. - Fixed an issue where, if two enclosures were configured and the cable was pulled from each, then reattached in a swapped configuration, the system would hang on boot. - Fixed an issue where successive power cycles in a multi-enclosure configuration could result in offline drives or a system hang. - Fixed an issue where, with the controller mux set to 'Auto', configuration would be lost during reboot. - Fixed an issue where rebuilds might fail to resume after enclosure power is restored. - Corrected several issue where the consistency check was not properly handling double medium errors. - Ensured that BGI (Background Initialization) setting was retained during foreign configuration import. - Fixed an issue which caused MSM to not allow creation of additional virtual disks once 16 virtual disks existed. - Fixed an issue that caused a hang if a rebuild was in progress when a configuration was migrated from an IR to an MR controller. - Fixed an issue where load balancing would not resume properly after a cable pull. - Fixed an issue where, during a target or chip reset, the Disk Write Cache setting on a SATA drive would be reset to default, which is generally 'enabled'. - Fixed an issue where, when BGI is aborted, the status for the CC (consistency check), rather than the status for the BGI, is reported. - Fixed an issue where, if a physical disk fails, causing a logical drive to become degraded, trying to clear or change the configuration would result in a hang until the failed drive was physically removed. - Fixed a hang that was seen when a cable was pulled just before system shutdown. - Ensured that a hotspare would revert back to hotspare state after a rebuild to that hotspare failed. - Fixed several issue that could cause "Illegal Request Sense Data" messages. - Fixed an issue where a rebuild would hang if one of the logical drives on the array was deleted during the rebuild. - Fixed an issue which could result in incorrect data in a scenario where RAID 50 arrays are running in a degraded state for an extended period of time. - Fixed several issues where medium errors could result in offline drives, incorrect data on drives, failed rebuilds, or system hangs. - Fixed an issue where, when a redundant path in a multipath system fails, some drives are marked offline. - Fixed an issue which could cause hangs when replacing a controller with an existing configuration. - Fixed several grammatical and formatting issues. - Fixed an issue where importing foreign configuration under CTRL-R could cause the firmware to crash. - Fixed an issue where an unresponsive SEP could result in a "greater than 122 devices detected" message. - Fixed an issue where the, after a RAID 6 is reconstructed as a RAID 5, the configuration is reported incorrectly upon reboot. - Fixed an issue which could result in incorrect data on the drives when I/O is run while a capacity expansion is in progress. - Fixed an issue that could cause a hang when an enclosure is power cycled while I/O is running. - Fixed an issue where, if a physical drive became invalid during a rebuild to that drive, the rebuild would pause, rather than fail. - Fixed an issue where Battery Warning messages would appear, even when disabled. - Fixed an issue which resulted in "Unexpected sense" messages in the log with SATA drives. - Fixed an issue where Cache Data could be lost during a power failure. - Fixed an issue where not all SATA drives were found during discovery. - Fixed an issue which may result in a firmware hang during a reconstruction operation. - Fixed an issue where the firmware would continue to try to communicate with a bad drive. The symptom of this issue is a drive where the status light is blinking amber and the activity light is solid green. - Fixed an issue where an enclosure reboot could, very rarely, cause a condition where the driver sends a Kill Adapter signal. - Fixed an issue where, if a medium error is encountered on a source drive during a rebuild, the bad block may not get marked as bad. - Fixed an issue where running in degraded mode with medium errors could cause the firmware to hang. - Fixed an issue where running heavy I/O on daisy-chained enclosures for an extended period of time could cause a hang. - Fixed an issue where, with some hardware, the configuration is not found within the timeout time on a cold reboot. This leads to a prompt to import configuration, after which, the configuration is seen correctly. - Fixed an issue with I2C LED support. - Fixed an issue where the write cache policy would unexpectedly change from write back to write through, then would change back after about a minute. - Fixed an issue where, if a cable is pulled in a multipath environment, the alternate path is sometimes not followed. - Fixed an error in the ECC error logging which can cause a memory leakage. - Fixed an issue where the firmware will hang if discovery does not complete in two minutes. - Fixed an issue where full initialization of a large number of SATA drives would cause timeouts. - Fixed several LED issues with I2C backplanes. - Fixed an issue sensing dual I2C backplanes in a multipath environment.
Functionality: - Added support for 64 virtual disks per array. - Added support for expanded RAID 1, a form of RAID 1E which supports even numbers of drives. - Added the ability to hot-swap a battery. - Added the ability to manually initiate the battery learn cycle. - Added multipathing support for SATA drives. - Added the ability to enable or disable NCQ from the CLI or WebBIOS. - Added the copyback feature, which is used when a drive goes defunct and the array rebuilds to a hotspare. Copyback allows the hotspare to rebuild to a new drive that is inserted to replace the defunct drive. - Clarified several log event messages. - Implemented load balancing when multipath SAS is used. - Added logging for some events that were not previously logged. - Increased the PHY count from 512 to 640 to support 21 enclosures.
Version 8.0.1-0036 - Non-critical ------------------ Fixes: - Address issue where SATA drives attached to an expander will not respond in a specific time period causing the drives to be seen as foreign. - Add support for the IBM ServeRAID 10il SAS/SATA adapter.
Version 8.0.1-0033 - Suggested ------------------ Fixes: - Fixed issue where current write policy is not changed to write back even if iBBU completes the charging in 1078 HWR. - Fixed an issue where the firmware reports "MonTask: line 3566 in file ../../raid/1078dma.c" while running reconstruction on a degraded logical drive and injecting media errors. - Fixed an issue where a controller would hang during a reboot. - Fix is done to invalidate the parity cache for the punctured block before releasing the cache line - Fix for WebBIOS hangs with greater then 5 MegaRAID adapters installed.
Version 8.0.1-0029 - Critical ------------------ Fixes: - Fixed an issue where, while performing I/O during a RAID level migration or an array capacity expansion, incorrect data may be passed during a data transfer.
Version 8.0.1-0027 - Critical ------------------ Fixes: - Implemented changes to ensure the firmware does not violate the DDR2 spec during the initialization sequence in a 1078 ROMB environment. - Fixed an issue where the controller enters MegaMon when a rebuilding span is removed. - Fixed an issue where the operating system may crash after an S3 resume followed by a manual restart. - Fixed an issue where a bad SAS cable, connected between two enclosures, could cause the firmware on the associated controller to crash. - Fixed a chip reset that could happen during boot sequence of RHEL 5 64-bit. - Fixed an issue where WebBIOS does not initially see external devices, and, if RAID is configured, the “missing config” prompt is shown in the BIOS. This was caused by the firmware not waiting for the second discovery attempt that is necessary to find external devices. - Fixed an issue where, on a 1078 chip, firmware was not properly marking a drive dead. Consequently, a write to that drive would appear to complete successfully, but would actually fail, therefore the data could be incorrect. - Fixed an issue where, under heavy load, with write back enabled, the following error was seen: "ERROR: Stale read check failure. Page image returned does not match previous write. Check hardware and caches. Read size was 16384" - Fixed an issue where import of foreign drive configuration would fail. - Fixed an issue where firmware could crash when a large number of hard drives is connected to a ServeRAID MR10M. - Fixed an issue where multiple reboots of cascading enclosures could result in incorrect data. - Fixed an issue where the Global Hard Drive Summary LED was not working. - Disallowed the addition of logical drives in an array that is being rebuilt. This fixes an issue where a newly created logical drive on a rebuilding array would be deleted on reboot. - Fixed an issue where the drive sizes were shown incorrectly after drive migration in an array with two or more different sized drives. - Fixed an issue where the source drive in a rebuild would be failed after several ECC errors.
Functionality: - Implemented Slot ID mapping support in a mixed topology. - Implemented a performance enhancement for sequential read workloads. - Reenabled offline hard drive firmware flash. Now hard drive firmware can be flashed in either an online or an offline state. - Implemented a new event so that dirty cache will be discarded on a virtual drive that is missing or offline.
Version 8.0.1-0021 ------------------ - Initial release ibm_fw_sraidmr_10m-11_0_1-0042_linux_32-64_chg
=============================================================================== Emulex FC/FCoE Device Driver for Linux ===============================================================================
Device Driver Version: 8.3.5.86
Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service
Interoperability since previous release: - RHEL6.3 GA Kernel
- Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix compilation errors on some kernels due to debugfs variable definitions. - Used PCI configure space read to flush PCI function reset register write - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset
- Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fixed port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix KERNEL allocation while lock held - Incorrect usage of bghm for BlockGuard errors - Fix warning on i386 system - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Support character device to take a reference on the driver - Fix for FDISC failures after firmware reset or link bounce - Support debugfs for injecting T10 DIF errors - Fix SLI4 BlockGuard behavior when protection data is generated by HBA - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Support more driver logs in area of SLI4 port error attention and reset recovery - Fix bug with driver returning the wrong ndlp - Sync up with actual upstream lpfc driver code - Support SLI4 16Gb FC Adapter support for T10 DIF / BlockGuard - Merge from upstream: scsi: Fix up files implicitly depending on module.h inclusion - Fix driver behavior when receiving an ADISC - Fixed unbounded firmware revision string from port caused the system panic - Fix bug with driver processing dump command type 4 using 16Gb FC Adapter - Fix driver does not reset port when reset is needed during fw_dump - Fix ELS FDISC failing with local reject / invalid RPI - Changed SLI4 FC port internal loopback from outer serdes to inner internal - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix bug with driver processing an els command using 16Gb FC Adapter - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtained link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed SLI4 16Gbit FC port internal and external diagnostic loopback tests - Fixed system panic during EEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing shost lock protection on setting/clearing bit in vport->fc_flag - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed illegal state transition during driver unload - Fixed system crash on SLI4 FC port looopback diagnostic test with large buffers - Fixed a potential error path that might try to free DMA memory not allocated - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix memory leak when running hba resets to SLI-4 board - Fix driver message 3092 and 3116 to KERN_WARNING - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Support loop for sli4 fc pass-through - No longer read fcoe parameters if board is not fcoe - Fix bug with driver passing a wrong count value - Support restore state and error log when sysfs board_mode attribute access failed - Fixed a typo in two of the log messages just introduced - Support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS. Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Return an error if the mbox sysfs is called - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when ASIC fails to initialize - Fix virtual fabrics bit set in FLOGI incorrectly - Fix bug with driver not returning extended mailbox data - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Modify WQ handling to use entry_repost - Moved link type definitions to apply to all driver streams - Support a sysfs attribute "protocol" to report SLI4 port link protocol type - Support SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Support structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fixed a warning when converting from simple_strtoul to strict_strtoul - Support Initial code to inject T10 DIF errors - Fixed a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Fixed null pointer dereference after clearing FCP policy rules - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Support check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fix sysfs lists fabric name for port that has been disconnected from fabric - Support FCP policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed fcp underrun reporting - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Support proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Fix compiler warning due to uninitialized local variable - Fix bus reset handler fails with bad failure code - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed sysfs API mismatch for building against SLES11 SP2 beta kernel - Fixed scsi midlayer queuecommand API mismatch for SLES11 SP2 beta kernel - Fixed ctlreg write bug not checking key string and limiting bytes to write - Fix default adapter name for the OCe15100 - Fixed incomplete scsi messages displayed - Fix cable pull failure on interface type 2 SLI-4 adapters - Fix enable_bg config parameter for SLI4 - Fixed not able to perform firmware reset through sysfs board_mode attribute - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix request firmware support for little endian systems - Fix driver firmware to match new firmware image format - Fixed SLI4 device firmware reset with SR-IOV virtual functions - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed handling of CVL for vports - Fixed crash when aborting els IOs - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Support fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - Fix issue where the FC/FCoE Async Receive CQE did not scale for 16G FC adapters - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Removed unused argument passed to the lpfc_bsg_diag_mode_enter routine - Fixed new ASIC device-mgmt BSG pass-through failed multi-buffer fw download - Support sysfs logging when writeable parameters are changed - Used PCI config space capability for sysfs get PF supported SR- IOV number of VFs - Support wait for SLI port status register for readyness following firmware reset - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - Consolidated duplicating macro definitions - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Modified log messages for T10-PI processing - iDiag fixed mailbox capture and dump overlapping bitmap macro definition
elx_dd_fc_ibm1206-8_3_5_86_rhel6_32-64_chg
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2 Latest Driver Version: 3.2.0.0 Document Updated: 12/18/2012 Product: Brocade FC HBA / FCoE CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.0.0 New Features and Feature Enhancement: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Fixes and Enhancements: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Version 3.1.0.0 Key features and enhancements supported for the software release 3.1.0.0 include the following:
New Features: - D-port support between Brocade 16Gb HBAs and Brocade 16Gb FC switch platforms with FOS v7.0.1 and later releases - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage - Performance enhancements in Ethernet drivers - Technology Preview support of 1860 HBA on Power PC architecture
Fixes or Enhancements: - Resolved an issue where HCM Agent may not start if BR1860 adapter is configured in NIC mode. - Improved stability with Hyper-V and Teaming configurations. - Resolved I/O errors when running traffic with Brocade HBAs(models 415, 425, 815, 825, and 804), if the server’s PCI max read request size is configured to be 2K or greater with PCI Gen2x8.
Version 3.0.0.0 Fixes and Enhancements: - Added support for Brocade 1860 AnyIO Fabric Adapter (User configurable port mode - FC or NIC or CNA) - Added Fibre Channel 16G Support - Enabled Fabric Assigned Address in Fibre Channel Fabric - Added PF based Virtualization – vHBA - Enhanced CLI, HCM GUI and CIM support in inbox drivers. - Added PF based Virtualization - vNIC - Added iSCSI over DCB Support - Added Multiple Tx Priority Queues Support - Added SNMP Support
Version 2.3.0.3 Fixes and Enhancements: - Enhanced SNIA API to report port speed of 4 and 8Gbps in SNIA format. - Enhanced XIV array interoperability that addresses a data integrity corner case. - Enhanced the transmit path handling in Linux Network Driver to avoid a corner case that could lead to transmit path stall. - Enhanced the Linux Adapter Software installer script to update the initrd with the correct name even when there are multiple copies of the OEM specific initrd(s).
Version 2.3.0.0 Enhancements: - Enabled HP DL120 server to support Boot over SAN with two Brocade HBAs installed. - Improved network driver CPU and performance optimization. - Enabled automated target and LUN discovery of enterprise HDS storage once LUN masking has occurred. - Improved Tivoli interoperability to meet device display requirements.
Version 2.2.0.1 Added capability to handle ADISC frames. Unhandled ADISC use can cause SAN boot failure when booting from IBM storage array.
Version 2.2.0.0 Adds support for bootcode updates to Bladecenter 10G Converged Network Adapters
Version 2.1.0.0 Adds support for bootcode updates to 10G Converged Network Adapters
Version 2.0.0.0 Initial release for 4/8G FC HBAs brcd_dd_fc_bfa-3_2_0_0_rhel6_32-64_chg
Multi-boot Image for 4Gb FC HBAs Release Notes Package Version MB_1.90-3
This software license applies only to QLogic customers. QLogic Corporation. All rights reserved.
Table of Contents
1. Version 2. 4Gb BIOS 3. 4Gb EFI 4. 4Gb FCode 5. Trademarks 6. Notices 7. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and release details that apply to the multi-boot package for 4Gb HBAs, version MB_1.90. This package is a compressed file that contains:
* BIOS version 2.16 * EFI version 2.27 * FCode version 3.13 * Firmware version 5.03.06
Rev 1.00 Jan.20, 2005 Initial release. Rev 1.01 Feb.18, 2005 Added code to put Port ID of device in IOCB. Rev 1.02 Mar.28, 2005 Added support for Serial Link Control. Addded code to display slot, bus number and function in CTRL-Q utility. Rev 1.03 Apr.18, 2005 Fixed bug when no drives attached and connected to switch. Added code to reset ISP if ISP is paused when ISR is called. Rev 1.04 June 8, 2005 Fixed bug in CTRL-Q utility that caused adapter id to be displayed at invalid id's. Added code to set Write Protect in Flash Status reg. Fixed bug in CTRL-Q utility where EAX reg was being corrupted by timer interrupt routine. Fixed bug in setting up LUN field in IOCB. Fixed bug in not setting port ID when connected to a switch. Rev 1.05 Sept 27, 2005 Changed code to suppress padding firmware version with leading zero's. Fixed bug in setting data direction flags in IOCB for 'seek command'. Changed code to not count device if device disabled by system BIOS. Fixed bug in setting flash Write Protect. Rev 1.06 Oct. 13, 2005 Fixed bug where anykey could invoke Fastutil. Rev 1.09 Nov. 22, 2005 Changed buffer request size to 2056 bytes for 'Report Luns' command. Fixed bug where GAN_NXT IN_ID was not always being set to zero causing GAN_NXT to fail. Rev 1.10 an. 31, 2006 Added check for optional boot mode flag to allow code to configure 1 drive/port when enabled. Bit 6 of host parameters in NVRAM is set to enable this mode. Fixed bug when Spinup-Delay and link is down. Added code to not display Data Rate option in CTRL-Q for QME2462. Rev 1.11 Feb. 7, 2006 Added support for interrupt polling. This option is controlled by bit 7 of NVRAM Host Parameters and by new Advanced Settings option in CTRL-Q. Rev 1.12 Feb. 21, 2006 Changed format of PnP string to display when Opt Boot Mode enabled in NVRAM. Added check for ELS reject status from Login IOCB. Rev 1.13 Apr. 04, 2006 Fixed bug in not always setting port id for logout IOCB. Changed code to support up to 16 adapters and 16 drives. Rev 1.14 Apr. 17, 2006 Changed code to ignore CLP '_hss' string. Rev 1.15 Apr. 20, 2006 Added code to wait for Login to complete when login pending status detected. Rev 1.16 May. 4, 2006 Fixed bug in not setting up Luns/Target in CTRL-Q. Added code to support Restore Default option CLP string (PCI3.0 BIOS only). Changed timeout value waiting for Linkup status from 6 seconds to 23 seconds. Rev 1.17 June 29, 2006 Added support for restoring defaults using CLP string (Pci3.0 only). Optimized code waiting for Linkup status. Added code to use Memory Map I/O for PCI express. Added code to check for correct Max Payload Size on QLE2464. Rev 1.18 July 19, 2006 Added code to load Nec switch port 1 and 2 pci config regs offset 68h with port 0 config offset 54h value. Fixed bug where task attributes in IOCB type 7 were not always being initialized. Rev 1.19 July 24, 2006 Fixed bug in CTRL-Q utility configuring Luns using Report Luns data when lun list has more lun entries after lun 255. Rev 1.20 Aug 2, 2006 Added code to support QLE2xx. Rev 1.21 Aug 24, 2006 Fixed bug in CTRL-Q cursor positioning for some user input displays. Rev 1.22 Sept 11, 2006 Added support for 'exit' CLP string. Changed CLP string to support new format: 'PermanentAddresses' was changed to 'PermanentAddress. Rev 1.23 Oct 16, 2006 Fixed bug in not setting rc_hba when different adapter types installed in system. Rev 1.24 Nov 29, 2006 Removed Extended Error Logging option from CTRL-Q. Removed code to use Memory Map I/O for PCI express. Rev 1.25 Dec 12, 2006 Added code so that set Defaults only to restores factory setting when value was modified by CLP string Rev 1.26 Dec 20, 2006 Fixed issue with the handling of CLP WWNN string. Also added code to always set firmware nodename optiom when set Default CLP is received. Rev 1.27 Feb. 26, 2007 Added support for Set Capabilities CLP string. Added code to load PLX switch port 1 and 2 pci config regs offset 68h with port 0 config offset 54h value (this is same code used for NEC switch). Rev 1.28 Apr. 12, 2007 Added code to check if need to restore HBA default portname. Added check for command fail status after login cmd. Restored code to read block 0 to determine drive geometry. Added NVRAM option (host_params bit 8) to enable support for HP boot order. Fixed bug in handling CLP Set Capabilities data. Rev 1.29 May. 22, 2007 Restored CTRL-Q Lun per Target option and changed text from 'Boot order' option to 'Controller order'. Rev 2.00 Dec. 03, 2007 Added support for ISP2532. Rev 2.01 Jan. 17, 2008 Added support for 1Gb data rate for 4Gb HBA. Rev 2.02 Feb. 18, 2008 Changed code to clear 'Disable Serdes' flag for CLP string Restore Default. Rev 2.03 Mar. 12, 2008 Added support for ISP8423. Added code to support new CLP 'set capability' spec. Rev 2.04 Mar. 23, 2008 Changed code to not used bit 13 of Host parameters. This avoids potential confict with inbox driver. Rev 2.05 Jun. 3, 2008 Added code to allow 2 min for link to come up when spinup delay enabled. Added code to poll for keyboard status. Removed external Loopback test option for ISP8432. Added check if IO support valid. Added check to CLP set_capablity string for the correct HBA port. Rev 2.06 Jun. 18, 2008 Added support for new CLP 'set capability' serial link spec for ISP2532. Rev 2.07 Sept. 3, 2008 Added additional error message for Verify Disk utility when device does not support SCSI cmd 2fh. Add support for Extended HBA CLP strings. Rev 2.07.6 Sept. 12, 2008 Fixed bug with 'restore netport defaults' when restoring NPIV's. Added code to reset ISP before accessing NVRAM the first time. Rev 2.07.8 Oct. 22, 2008 Added support for IDT PCIe switch Fixed bug in restoring NPIV after updating with CLP. Rev 2.08 Oct. 30, 2008 Removed TEST ONLY from BIOS banner. Rev 2.09 Dec. 02, 2008 Added code to save some pci data. Added new option to Advanced Option menu in CTRL-Q for Virtual Fabric Enable/Disable. Rev 2.10 Feb. 24, 2008 Added support for ISP8001 Added check for INT Polling before updating interrupt controller(PCI3.0) Fixed bug where eax register was being corrupted in nvram_config routine. Removed option in CTRL-Q for Virtual Fabric Enable. Fixed cosmetic bug in displaying selectable boot lun in CTRL-Q utility. Rev 2.11 Apr. 28,2009 Fixed issue with setting up Init FW MB command for using Extended Init Control Block Added option in CTRL-Q utility for Primary FCF VLAN ID for ISP8001 HBA. Added code to check version field of Extended ICB. Added code to correctly identify pci switch on 4 port HBA's. Changed code to suppport Loopback mode with new version of FW. Rev 2.12 May, 15,2009 Changed code to handle HSS CLP vendor id 3 same as vendor id 2. Rev 2.13 July 16, 2009 Added code to save backup copy of VPD/NVRAM data. Rev 2.14 Oct 9, 2009 Changed code to use FS segment register instead of GS in find_device routine. Change code to preserve MSB of WWPN Set Capablity CLP when updating WWPN/WWNN. Rev 2.15 Nov 23, 2009 Added code to handle 'About FW' mailbox command timeout. adapter. Rev 2.16 Mar 16, 2010 Fixed bug in not setting Write protect for single port adapter.
Driver Name : Fibre Channel Driver for UEFI Version : 2.27 Date : 05/9/2010 OS platform : N/A FW version : See MultiBoot release notes for FW version. Efiutil Version : 2.86
Table of Contents I. Overview II. Enhancements III. Bug Fixes IV. Known Issues V. Additional Information
I. Overview
The following document provides details of the Fibre Channel UEFI driver version 2.27, Efiutil version 2.86.
II. Enhancements
None
III. Bug Fixes
Driver: * Removed Extra character and NULL string message from HII. (ER71174, ER71175) * Add support for 8GB data rate for 25xx family in HII form. (ER71118) * Add fix in driver to avoid to print driver messages on splash screen during system boot up. (ER71099) * Add support for HII Protocol. (ER55486) * Added fix to allow W2K8 boot from local disk when target is mapped in passive path. (ER70069) * Added fix to diplay firmware version info correctly in HII "Adapter info" menu. (ER71412) * Display error message in HII form if invalid HBA parameter value is set (Execution Throttle). (ER71533) * Fixed a bug that caused VPD version numbers to be displayed wrong. (ER70907) * Add fix for NULL string message displayed on Hx5 system. (ER71771) * The "Enable Loop ID" bit in the HII menu is now set correctly. (ER71885) * Rename "Reconnect and Exit from Main Menu" HII entry to "Exit from Main Menu".
Efiutil: * Add fix to avoid, overwriiting of orignal SERDES file, if user give wrong command. (ER69941) * Added fix to avoid, "unaligned reference fault", while updating flash. (ER69793) * Add support, to ignore locked fileds while updating firmware area. (ER69531) * Add fix to display firmware version correctly. (ER71468) * Add fix to display new firmware version correctly while updating multiboot image. (ER71468) * Add support for 82xx family in Adapter list. (ER69230)
IV. Known Issues
* In the HII menus, Adding/Deleting a Target/LUN will require a reboot for changes to take effect.
V. Additional Information
* Efiutil and the EFI Driver are a matched set. Always make sure that Efiutil and the EFI Driver are from the same release package.
Release Notes for 4Gb FC HBAs (FCode) ================================================================
version 3.13 03/26/10 * Change REV_LEVEL in rev_level.m4 from 3.13b9 to 3.13. Offical Release.
version 3.13b9 03/24/10 * Remove Explicit logout to fabric(FLOGO) in close-hardware, put in v3.13b3. * Restructure fcode source files. Add: isp-init.fth, p3-init.fth, mailbox.fth, properties.fth, structs.fth, regs-isp.fth, regs-p3.fth, utils.fth.
Version 3.13b8 03/09/10 * Add Parameter 1 debug display on login IOCB faliure if debug-logi? is set. * Add force-open-ok? test flag in open method. Default = true(no real change). * Change get-to-params to set boot-wt = 8 secs if boot-wait-time is disabled. * Fix bug in VPD fetch, introduced in v3.13b1. vpd-buf increased to 512 bytes. * Change cbuff back to non instance buffer. Instance has no effect on buffer:.
Version 3.13b7 03/04/10 * Remove Hard-RICS-reset from reset-risc method. Causes problems on QMI2582. * Remove Eddy test= Reset RX-Serdes after 5 secs wait for in isp-fw-ready?. * Make old-sb (old sec-buf) an instance value. Problem on M3000 (ER70453).
Version 3.13b6 03/02/10 * Add Reset RX-Serdes after 5 secs wait for in isp-fw-ready?. Plus add debug.
Version 3.13b5 03/01/10 * Add more debugging in isp-fw-ready?. Print fw-state each time in get-state. * Change getnum to use the 'accept' word and make cbuff an 'instance' buffer:.
Version 3.13b4 02/24/10 * Fix Explicit logout-device IOCB to include the ISP PortID and Port WWN. * Changed debug? flags: 4000= Got-R2H-intr, 2000= IOCB-Dump, 800= FW-Ready-wait.
Version 3.13b4 02/22/10 * Fix Explicit logout-device IOCB to include the ISP PortID and Port WWN.
Version 3.13b3 02/19/10 * Use OpenBIOS Toke Tokenizer to make isp2500/8100/8200. isp2400 uses SUN toker. * Add Implicit logout-all and Explicit logout to fabric in close-hardware. * Add setting the FW ICB link-down-NOS/OLS value for isp2400/2500 (ER67806).
Version 3.13b2 02/11/10 * Change set-boot-wait-time to not affect link-down-to (timeout) for Fujitsu. * Change login-devices to not logout with FC_Initiators. * Change logout-device to use implicit Logout, not explicit. (Fix P3P problem)
Version 3.13b1 02/05/10 * Change set-boot-wait-time to be entered/display in decimal, not hex(Fujitsu). * Added OpenBIOS 'toke' Tokenizer to makefile. Now you can make either version. * Fixed bug introduced in ISP2400 v3.10. Defered word fmw_ofs, never defined.
Version 3.12 01/11/10 * No change to isp2400, fixed SSDID for Sun (SUNW,qlc) CNA QLE8142.
Version 3.11 12/11/09 * No change to isp2400, added support for Sun (SUNW,qlc) CNA QEM8152.
Version 3.10 12/02/09 * Change the name of the top level Fcode file from isp2xxx.fth to ispxxxx.fth. * Change makefile to include the creation of P3+ isp8200.xxxx.fc binaries. * Introduced bug for defered word fmw_ofs, never defined for ISP2400.
Version 3.09 10/26/09 * Change REV_LEVEL in rev_level.m4 from 3.09b1 to 3.09. Offical Release.
Version 3.09b1 10/22/09 * Fix Node-Name-Option bit preservation in restore-default-settings. ER68181.
Version 3.08 10/19/09 * Change REV_LEVEL in rev_level.m4 from 3.08b1 to 3.08. Offical Release. * Remove patch of PCI header image size byte at offset 0x2c from init version. * Fix flash-word! bug introduced in veersion 3.08b1. Affects ISP2400 only.
Version 3.08b1 10/14/09 * Fix default WWNN & WWPN preservation in restore-default-settings. ER67924. * Fix stack bug when link down. Introduced in v3.05 set-phandle word. ER67926. * Add standard properties. Use m4 utility to automaticly create date string. * Add file rev_level.m4 which has the revision level strings only. * Add FCoE & 4Gb IBM mezz cards QMI8142 QMC2462 QMI3472 QMI2472 to imezz? word. * Change messages "Login failed" to "Login Abort". "Error Subcode" to "Subcode". * Re-structure Flash/NVRAM access fnv-wd@/! words for the Netxen P3 integration. * Add 'make nx3031' to makefile for Netxen P3. #ifdef P3 used for delineation.
Version 3.08b1 09/25/09 * Add standard properties. Use m4 utility to automaticly create date string. * Add file rev_level.m4 which has the revision level strings only. * First version with some support for the Netxen P3 CNA.
Version 3.07 09/08/09 * Change version string from 3.07b2 to 3.07. Offical Release for IBM and SUN.
Version 3.07b2 09/04/09 * Fix read-cap16-cmd. Used when the LUN size is >2TB (i.e. #blocks > 32-bits). * Fix disk-test to work with large >2TB LUNs, where the LBA >32-bits.
Version 3.07b1 08/28/09 * Remove command retry when 8048 AEN is received. Caused DMA error found by IBM. This was an old workaround put in vers1.08b2, before IOCB timeouts were set.
Version 3.06 08/19/09 * Change version string from 3.06b6 to 3.06. Offical Release for IBM. * Fix qlgc-debug? option for IBM. Use find-method on IBMs and $find on SUNs.
Version 3.06b6 08/18/09 * Add option for qlgc-debug? in nvramrc. If the diag-switch? is true, then the debug? flag is set is set to the value of qlgc-debug?.
Version 3.06b5 08/18/09 * Add lba64 large disk capability (read-blocks64 write-blocks64) for SUN only. * Add support for QEM3572, SSDID = x172, for SUN only. * Add mbox1 & mbox2 display for 8048 interrupt if debug-asyc? flag (01) is on.
Version 3.06b4 08/13/09 * Fix bug in IBM fcp-luns method for the Controller LUN-0 check, lun0-check.
Version 3.06b3 08/12/09 * Check Inquiry Qualifier field of Controller LUN-0 in IBM fcp-luns method.
Version 3.06b2 08/10/09 * Add more IOCB debugging, Add Erase Response-Queue in mapmem. Had stale data.
Version 3.06b1 08/08/09 * Add more debugging for IOCBs, dma-map-in/out, & wait-for-interrupts.
Version 3.05 08/04/09 * Change version string from 3.05b2 to 3.05 Offical Release for IBM.
Version 3.05b2 08/03/09 * Fix set-fc-address issue found with IBM ioinfo. PortID was not getting set. * Re-structure devicepresent.fth. Add set-phandle to set obp-target & obp-portid
Version 3.05b1 07/31/09 * Fix multiple close issue found with IBM ioinfo utility.
Version 3.04 07/22/09 * Add "ibm,write-supported" property to disk child node, as per IBM's request.
Version 3.03 07/13/09 * No change, affected ISP2500 & ISP 8100 Fcode only.
Version 3.02 05/06/09 * No change, affected Schultz ISP8100 Fcode only.
Version 3.01 04/23/09 * No change, affected Schultz ISP8100 Fcode only.
Version 3.00 04/21/09 * Added more debugging information for AEN 8014.
Version 3.00b8 04/01/09 * No functional change, binary files differ. Only ISP2500 Fcode affected.
Version 3.00b7 03/31/09 * No change, Schultz ISP8100 Fcode only.
Version 3.00b6 03/04/09 * Change boot-wait-time to start timer(fw-ready-start) in isp-fw-ready method. * Change fix-rbios to check nvr-bad? before copying nvram to RAM.
Version 3.00b5 02/25/09 * Change link-down-timeout to boot-wait-time if bootwait-enable flag is true. * Add ILT support for SCHULTZ only. No effect on ISP2400 * Changed era-code (used in ldfcode) to use /code to determine #secs to erase. * Add set-cd-base+siz (used for ldfcode) to replace set-ld-base & set-/dlc.
Version 3.00b4 02/11/09 * No change. Changed flash-acc-data & offsets for ISP8100 only.
Version 3.00b3 01/21/09 * No change. Changed reg property for ISP2500 and ISP8100 only.
Version 3.00b2 01/08/09 * Added set-boot-wait-time commnad for all 4 & 8Gb HBAs/CNAs. Add NVRAM Fcode 2-byte parameter, boot-wait-time, at ofs x15a & enable-bit(x20) at ofs x158. This was requested by Fujitsu, for disks that take longer to come online.
Version 3.00b1 12/19/08 * Add Schultz ISP8100 support. No change to ISP2400 methods. * Added more SCSI sense debugging. * Reworked interrupt service routines with more debugging.
Version 2.04 12/03/08 * Change version string from 2.04b2 to 2.04 Offical Release.
Version 2.04b2 12/02/08 * Remove set-bootid, set-boot-wwn, & releated qla only words from IBM version. * Added IBM debugging to BOFM words and set debug?=C00 if diag-switch is true. * Added max-payload bridge fix for 4-port QMI2464 HBA. Used Gil's method. * Fix get-mail to handle Response-Queue interrupts (stat=13) & add debugging.
Version 2.04b1 07/23/08 * Preserve Flash area x40000-x80000 which has FW-Area, Flash Tables, NPIV data * Fix open to always return -1. Returning link-down fw-state fails on Serengetti
Version 2.03 06/30/08 * Change version string from 2.03b1 to 2.03 Offical Release.
Version 2.03b1 06/06/08 * Use complete NVRAM values for fwopt2 and fwopt3 in fw-init, initialize ICB.
Version 2.02 05/07/08 * Change version string from 2.02b3 to 2.02 (Offical Release). * Fix load-image to return error status so you can exit on failure. * Remove stop-fw from isp-probe method. It did nothing since FW is not loaded.
Version 2.02b3 04/17/08 * Change compatible property to append to existing property, if it exists. * Change all references in the Fcode of 'HBA' to 'Adapter' (for QLE8000 CNA).
Version 2.02b2 04/14/08 * Fix compatible prop for IBM. Return DDDD value back to DevID in strings: pciVVVV,DDDD.SSSS.ssss.RR & pciVVVV,DDDD.SSSS.ssss. DDDD was = SSDevID.
Version 2.02b1 03/27/08 * Fix blank lines in list-wwns for set-boot-wwn command in qla-mode. ER59591. * Change the d-mbox (dump-mailbox) word to use the .4z data format macro. * Add Access Menlo Data IOCB to allow displaying & changing Menlo configuration. * Add Menlo version number to the version command (Menlo only).
Version 2.01 03/27/08 * Change version string from 2.01b2 to 2.01 (Offical Release).
Version 2.01b2 03/05/08 * Change SubSystem Device ID from x0169 to x014B for Sun QEM3472 HBA. * Add sunid-bit = x10 to Fcode Parameter word (offset x158) in NVRAM.
Version 2.01b1 03/03/08 * Add support for Sun QEM3472 with SubSystem ID = 0x0169, node name SUNW,qlc. * Add QLE3000 Mercury HBA support. * Fix selftest mem-siz = x20000 (128KB) on IBM CFFe/CFFx mezz cards.
Version 2.00 02/15/08 * Change version string from 2.00b17 to 2.00 (Offical Release).
Version 2.00b17 02/07/08 * Modify ldfcode again to skip copy of WWN and checksum to BIOS-defaults area.
Version 2.00b16 02/05/08 * Modify ldfcode to copy all BIOS-defaults plus copy Model & DID to header. * Fix login-devices to return #ports, including non-target ports. This fixes Sun Bug ID 6645537, ER58525, where LUNs were not listed when Emulex present.
Version 2.00b15 01/29/08 * Fix target login problem with McData switch by adding GID_PT command. ER58769. * Modify ldfcode to poke BIOS default area of the MB-image with Model# & SSID.
Version 2.00b14 01/15/08 * Fix restore-default-setting to skip SSDID, OEM Specific Area, Feature Mask, and Model# copy to NVRAM. Also add revert-wwns on IBM. ER58465 & ER58509. * Replace load-stub-fw with stop-fw mbox command for PCIe 2400 HBAs. Firmware vers 4.00.25 or greater stop-fw command will do the same thing as stub FW. * Fix IBM BOFM bug where the default WWPN is lost if a new WWPN is written twice
Version 2.00b13 12/21/07 * Separate 2400/2500 Fcode into two binary output files (isp2400/isp2500). Remove isp2500? & use #ifdef ISP2500. Resulting in smaller 37KB image size. * Add use-cdb16? flag which is set in read-capacity if the target supports Large LBA. 16-byte CDBs are used only if use-cdb16? is set & LBA > 32-bits. ER58285. * Fix "chrp" string in papr-compliant? word (IBM BOFM support). * Change write-wwnn word to check for new-wwnn=0 (IBM BOFM support). * Add enab-nvr-acc to all 6 BOFM external words so they work on unopened dev.
Version 2.00b12 12/10/07 * Add init-chip? to sns-command & logout-devices for recovery from link-down. * Put ifp-abort back into wait-for-risc-int, which was taken out in vers 1.23.
Version 2.00b11 12/05/07 * Move clearing of flags link-up?, done-fw-init? port-updated? to reset-risc. This was for isp2500 set-boot-wwn failure because FW was stopped. ER58139.
Version 2.00b10 11/30/07 * 2500 change only. ER58002.
Version 2.00b9 11/28/07 * Fix find-image to check for last-image bit and exit loop if found. ER57989. * Fix init-fw problem. If NVRAM is blank, FW Option word-1 is not set in ICB.
Version 2.00b8 11/21/07 * Make BOFM support words external in IBM version. * Change my-wwnn@ to return WWNN based on current adapter WWPN. (IBM version) * Fix stop-risc bug. Clear done-fw-init? flag before calling mail. ER57926.
Version 2.00b7 11/12/07 * Remove 'ibm,' from the BOFM support words for IBM. Also update property. * Add check-managed-wwn which checks for PAPR-compliant & san_wwn string in root prop " ibm,managed-address-types" and then reverts WWNs if necessary.
Version 2.00b6 10/18/07 * Changed makefile to create separate isp2400 & isp2500 images(PCI header only). * Fix drate-val (default Auto Data-Rate value) w/o shift for selftest. * Fix n-port topology device-present problem. obp-portied was not getting set. * Add back architecture check (wrong-arch?) of PCI header DEVID during flashing. * Add rd-ram-wd and wr-ram-wd mailbox commands for debugging purposes. * Add BOFM support for the IBM version Fcode.
Version 2.00b5 09/24/07 * Combined 2400/2500 Fcode into a single binary output isp2x00 file. Use isp2500? word instead of #ifdef ISP2500. Resulting image size is now 38KB. * Changed Connection Mode & Data Rate debug messages during FW initialization.
Version 2.00b4 09/18/07 * Shrink code wherever possible. Remove unused words and shorten value names. * Fix find-fc method to add Func0 bc0_ofs. Otherwise it checksums Func1-fcode.
Version 2.00b3 09/07/07 * Add reset-risc to reopen-hardware method when init_link?=0, for INIT version.
Version 2.00b2 09/06/07 * Fix selftest to always use Auto-negoiate data-rate. ER56565. * Fix open for selftest to return OK status when link-down on a reopen. ER56566.
* Fix version number in PCI header. Should be 2.00.
Version 2.00b1 08/28/07 * Add 2500 support with major change in NVRAM and Flash utilities.
Version 1.27 08/21/07 * Change version string from 1.27b11 to 1.27 (offical release).
Version 1.27b11 07/31/07 * Move init-chip to reopen-hardware so FW loads in show-children if link-down. * Make chip-base, exprom, lun-index and port-update-occurred instance values. * Make link-up a Hard (not instance) so it stays set between instances. ER55858.
Version 1.27b10 07/11/07 * Fix find-dflts and dflt-wd@ to now handle 2-byte alignment in BIOS. ER55660.
Version 1.27b9 07/03/07 * Remove QLE2464 PCIe Dev control reg max-payload-siz set from 1.26b9. ER55588. * Added Data Rate command when debug-init is set, to display actual data rate.
Version 1.27b8 06/22/07 * Add setting WWPN bit-56. This bit is clear in the WWNN. This fixes a potential problem when OEM (DTI) uses oemutil to set the adapter's WWPN. Matches driver. * Add setting FW Option 1 word in ICB. Never reported as a problem, but... * Fix stack bug in login-device when comp-status is invalid(eg. 99). ER55423.
Version 1.27b7 06/11/07 * Fix stack bug created in 1.27b6 on Bad IOCB Entry Status. * Add Execute command error debug level x40 and rework debug levels.
Version 1.27b6 06/05/07 * Remove fc-mode, set-fc-mode (qla-mode) words from IBM version. * Change IOCB fail messages to show only when the debug? 08 bit is set. ER55150.
Version 1.27b5 05/24/07 * Fix restore-default-setting to skip the Adapter WWPN copy into NVRAM. ER55009.
Version 1.27b4 05/14/07 * Add re-login when IOCB status =x29|x28, which will init-chip & login-device. This change was made to handle cable-pulls during boot. ER54837. * Change debug messages: Loop Up/Down to Link Up/Down & add test-unit-ready. * Change makefile to create 256k byte Fcode-only images to be used with SCLI.
Version 1.27b3 05/03/07 * Add back restore-default-settings but restore entire NVRAM from BIOS defaults. * Fix ibm-encode-unit to drop LUN if =0 & remove leading zeros, like 2312 Fcode.
Version 1.27b2 04/03/07 (Sent to Lyle) * First pass at adding NVRAM max-frame-size in FW ICB. Based on vers 1.26b10.
Version 1.27b1 03/22/07 (beta version given to IBM) * Add 16-byte SCSI CDB read/write commands for LBA >2TB. Based on vers 1.26b10.
Version 1.26 05/17/07 * Change version string from 1.26b21 to 1.26 (offical release).
Version 1.26b21 04/26/07 * Remove error messages for 'TUR failed' & SCSI 'Retries exhausted'. ER54516.
Version 1.26b20 04/25/07 * Remove restore-default-settings for 1.26 rel. Put a complete restore in later.
Version 1.26b19 04/25/07 * Change version-prop "Host Adapter Driver" to "Host Adapter FCode". ER54455.
Version 1.26b18 04/24/07 * Fix list-wwns to not call get-portname-db if invalid topology. ER54434.
Version 1.26b17 04/19/07 * Add NVRAM parameters restore-default-settings, with confirm question. ER54346. * Stop using the bios-compatibility-mode bit in NVRAM and remove set-mode command since it is no longer used in the 4Gb FCode (needed for 2Gb only). * Move all of the NVRAM access methods into a separate file, nvram.fth.
Version 1.26b16 04/18/07 * Add show max-frame-size (show-maxfs) to show-settings. * Fix bug in VPD data fetch (vpd@) word. Need to poll ready bit. ER54345.
Version 1.26b15 04/13/07 * Fix max-frame-size typo in menu, should be 1024, was 1048. * Fix version number in PCI header, was 1b(1.27), should be 1a(1.26).
Version 1.26b14 04/13/07 * Change max-frame-size to use a 3 choice menu, 1-512, 2-1024, 3-2048. ER54229.
Version 1.26b13 04/12/07 * Add Fcode usage of NVRAM parameter, max-frame-size in FW initialize ICB. * Add word, set-max-frame-size, for changing this NVRAM parameter. ER53990.
Version 1.26b12 04/10/07 * Fix inquiry? to check for no-data xfer. Problem seen when LUN#>255. ER54103. * Add 16-byte SCSI CDB read/write (x88/x8a) commands for LBA >2TB. IBM request. This change does not effect the old 6-byte & 10-byte SCSI CDB reads/writes.
Version 1.26b11 04/04/07 * Change word show-boot-wwn from being 'external' to 'header', so it is not visible with fcode-debug? flag =false. Requires change to readme.txt. ER53873.
Version 1.26b10 03/02/07 * Fix stack bug, introduced in 1.26b8, in display-luns when report-luns fails. * Remove comp-status=6 error message on commnad timeout in execute-command. * Go back to using tar.Z instead of zip format for release files.
Version 1.26b9 03/01/07 * Set timeout field in IOCB prepare-command. Timeouts were disabled! ER50089. * Change qla-mode use-bid? flag back=0. It does not need to match the bootID. * Add QLE2464 max-payload-size in Device Config Reg, offset x54.
Version 1.26b8 02/07/07 * Remove debug? flag set if diag-switch? environment variable is true. * Add Work-around delay in show-children to give FW time before issuing IOCBs.
Version 1.26b7 02/06/07 * Add login-device in show-loop-devices to fix bug with StorEdge 3511 minnow. * Fix display-inquiry stack bug when inquiry command fails. * Fix sense buffer check for illegal request in report-luns method. * Remove LUN0 inquiry command execution in display-luns, when report-luns fails. * Removed "Warning: NVRAM boot-id should be=" when in qla-mode, & loop topology.
Version 1.26b6 02/01/07 * Reduce /lunbuf to x10000 for MACs. This reduces max-luns from 16k to 8k. * Change to use NVRAM boot-id when in qla-mode for fabric topology, use-bid?=-1.
Version 1.26b5 01/25/07 * Fix bug in fp.fth. logout-device was not present. Needed since v1.25b6. * Start using port-down-rc retry-count in spin-up and rw-blocks scsi commands. * Disallow 0 entry for set-link-timeout set-port-down-count & set-login-count. ER51830 and ER51857.
Version 1.26b4 01/17/07 * Change data-rate menu to use 'Gb/sec' instead of 'Gigabit'. ER51678.
Version 1.26b3 01/12/07 * Add LUN list and lun-present? check to qla-mode set-boot-wwn method. ER51224.
Version 1.26b2 01/05/07 * Add Atmel 26DF081A Flash support. * Fix ldfcode to set DevID field in all PCI image headers.
Version 1.26b1 12/21/06 * Add Fcode usage of NVRAM parameters: login-retry-count, link-down-timeout. Currently port-down-retry-count is still not used by the Fcode. * Add words: set-login-count, set-link-timeout. & set-port-down-count for changing these NVRAM parameters. * Add hidden words: show-logincnt, show-linkto. & show-portdcnt for displaying these NVRAM parameters. * Add these new words to the show-settings list and the show-commands list. * Change display of boot-lun and boot-id to be both hex and (decimal).
Version 1.25 12/11/06 * Change version string for the 1.25 offical release.
Version 1.25b7 12/08/06 * Do not use NVRAM boot-id in qla-mode unless use-bid? flag is set, normally=0.
Version 1.25b6 12/08/06 * Fix qla-mode boot-id bug in fabric-wwn-to-handle. Was not using NVRAM boot-id. * Set limits on qla-mode NVRAM boot-id <= 7ff and on boot-lun <= ff. ER50909. * Add logout-device (of target boot-device) in close of scsidisk child.
Version 1.25b5 12/05/06 * Fix stack bug in login-device. This bug was induced in 1.25b2, LS_RJT fix. * Remove GID_PN fail mesage from fabric-wwn-to-handle & display if debug? on. * Change SN# fetch in show-settings to get it from the VPD data, not the WWN. * Add debugging to fcp-targets and fcp-luns. * In qlc-mode, disallow set-boot-wwn, set-boot-id & don't list in show-commands.
Version 1.25b4 12/02/06 * Fix GID_PN (0x121) & GPN_ID (0x112) SNS commnads to handle a null buffer.
Version 1.25b3 12/01/06 * Fix link-down topology=f case bug in device-present?. * Change ext-loopback-test to separate diag-init-chip & lb-ext (external).
Version 1.25b2 11/29/06 Fix login-devices bug on LS_RJT (found by Lyle), logout to preserve phandles.
Version 1.25b1 11/22/06 * Add show-commands. ER50338. * Add decimal display of target & Lun # in show-children.
Version 1.24 11/13/06 * Change version 1.24b3 string to the official release 1.24. * Change max-luns=16K for qlc-mode. Limit LUN field range to 8-bits in qla-mode.
Version 1.24b3 11/13/06 * Fix report-luns buffer & commnad, add 8 bytes for # of LUNs field. ER50220.
Version 1.24b2 11/09/06 * Change max-luns=256 (max # of LUNs per target) to match the driver. Was 1024. * Change execute-command to check status returned by login-device, & fail if bad * Change selftest to use init-chip which waits for fw-ready, instead of a delay.
Version 1.24b1 11/03/06 * Execute external-LB test from selftest only if in FL-port or NL-port topology. * Create command ext-loopback-test. Allows manual execution of External Loopback * Change ldfcode in flash-pgm to allow flashing of 1MB multi-boot images.
Version 1.23 10/18/06 * Change version 1.23b1 string to the official release 1.23.
Version 1.23b1 10/11/06 * Add ~2 sec. delay before executing show-nport-devices in show-children. * Added Level debugging. * Move tools directory up one level, so we don't keep a copy in every version.
Version 1.22 10/02/06 * Change version 1.22b5 string to the official release 1.22.
Version 1.22b5 09/29/06 * Fix isp2400-probe bug on PCIe HBAs. HBA regs were not mapped when load-stub-fw was executed. Also, moved isp2400-probe execution to the end of ifp.fth.
Version 1.22b4 09/19/06 1 Fixed list-wwns word so set-boot-wwn will work for N-port topology . 2 Fix selftest again so connection-mode always = Auto, during the test.
Version 1.22b3 09/15/06 1 Fixed get-id-list word to work for N-port topology on the ISP2400. 1 Increase max-fab-devs to 2048. 3 Change initial value of topology to x0f. (invalid) 4 Add show-settings word to list the HBA's settings. Make version word external. 5 Fix selftest to work independent of NVRAM connection-mode setting.
Version 1.22b2 09/11/06 1 Fixed processing of get-id-for-fc4type GID_FT buffer to check for null buffer. 2 Changed names of prom output files to isp2400.sun.fc and isp2400.ibm.fc.
Version 1.22b1 08/21/06 1 Add FW initialization stub loader at probe time & in close method. This is done only on PCIe HBAs (i.e. Dev-ID not equal to 2422). 2 The Makefile was changed: The tokenizer directory was changed to tools and a local copy of cpp and makearray are kept in tools. Tokenize and fakeboot are no longer used, and .out files are no longer created, only raw .fc files with no header. ldfcode will not work on older fcode, update with init version
Version 1.21 08/01/06 * Change version to non-beta after testing.
Version 1.21b1 07/18/06 * Change info-count from an instance value to simple value. This will limit the version banner to be displayed only once during the boot process.
Version 1.20 06/22/06 * Prohibit connection-mode change if DevID=54xx. Print: Model # will Auto-negotiate.
Version 1.19 06/14/06 * Release. Add support for QLE210, SSDID=x132(Sun) & SSDID=x13E(Qlgc).
Version 1.19b2 06/13/06 1 Prohibit data-rate change if DevID=54xx. Print: Model # will Auto-negotiate. 2 Add get-model-prop word. For printing model # if data-rate change is rejected.
Version 1.19b1 06/09/06 1 The memory size tested in mem-test will now be cut in half on all HBAs with Device ID = 54xx, such as the QLE220. The word reduce-func? was created. 2 Word for reading config space regs, vid@, did@, ssvid@, & ssdid@ were created.
Version 1.18 05/24/06 * Make v1.18b2 release v1.18
Version 1.18b2 05/23/06 1 Fix problem found on Sun T2000 PCIe. pci-compat-str did not handle dev-id=5432 2 Remove class-code-string2 word. It was producing a bad string pciclass,0400.
Version 1.18b1 05/19/06 1 Add support for several HBAs including the Sun QLE220 HBA with SSDID=x14E. 2 Add restriction of qla-mode change on all SUNW type HBAs. 3 Remove extra version string display during selftest. 4 Fix read-block-ext to only use read-capacity command, not try mode-sense first 5 Add display of non-zero FCP/SCSI status during debug mode. 6 Fix initialization of port-update-occurred flag during wait for isp-fw-ready?
Version 1.17 03/31/06 1 Put in Asif's fix for retry?(scsi.fth) to check sense length before IOCB copy. 2 Make my-wwn value external for IBM users. 3 Put in Asif's fix for ibm-decode-unit, to correctly parse out WWN and LUN# in cases where the LUN# may or may not be specified in the path. 4 Fix IBM set-address to correctly set obp-lun-lo and opb-lun-hi.
Version 1.16b11 03/28/06 * Make qla-mode? value in qlc parent & qla-mode? word in fp child node externel. Before fix, would not work if fcode-debug? = false.
Version 1.16b10 03/20/06 1 Fix fcp-luns for FL-PORT. Add 2dup so WWN is on the stack for f-port-fcp-luns 2 Make qla-mode? not instance value so show-devs will work. 3 Change fnv-access-to back (from x10 to x800) 4 Add set-timeout word back (needed for IBM). It was removed in b1.16b1
Version 1.16b9 03/08/06 * Change Firmware load-image to run faster.(very slow on serengeti) change read-code-segment to rd-code-seg. Change dly-val from 50 to 10. Move FLASH-ERR ifpcsr! to get-addr-len. Change fnv-access-to from x1000 to x10
Version 1.16b8 03/07/06 * Serengeti fix child creation. Put all if statements inside colin definitions. * Move scsicom.fth words into scsidisk.fth
Version 1.16b7 03/03/06 * Mod child creation. Use qla-mode? flag, not the property. Remove prop qla-mode * Change Loop init error message to print only if in debug mode.
Version 1.16b6 02/27/06 * Fix encode-unit to encode the lun target integer pair. Used in qla-mode.
Version 1.16b5 02/23/06 * Swap order of boot-wwn-hi & boot-wwn-lo in NVRAM (hi is now first) Always prompt for boot-target-id in set-boot-wwn.
Version 1.16b4 02/09/06 * Remove periods in display-wwn & display-inquiry,LUN. Now show-children looks the same as it use to. * Add 2-bit fcode-host field to fcode-parameter word (wd offset x56) in NVRAM. Value can be 00-SPARC, 01-IBM, or 10-MAC. This will effect the version string. The 01-IBM value should not be used. The IBM version is still a separte binary
Version 1.16b3 02/03/06 * Change Initiator test in login-device also. Test TARG-BIT of Service params. * Change show-login-devices & show-fabric-devices to skip display-luns if display-port-db fails. Check target bit done in get-port-db. Now FL-port works
Version 1.16b2 01/31/06 * Remove all #ifdef MAC instrustions. Make SUN version the SPARC/MAC version * Fix problem found @SUN w/6920, Change Initiator test in get-portname-db.
Version 1.16b1 01/30/06 * Add support for Apple MAC Fcode, using #ifdefs. Make it 32-bit compatable. * Add disk-test (read-write-read-compare) selected target with sel-dev & sel-lun Moved read-block-ext, timed-spin, r/w-blocks from sd node to parent qlc node.
Version 1.15 Beta_2 12/15/05 * Modify beacon word to flash top and bottom LEDs only!
Version 1.15 Beta_1 12/09/05 * Change node name to QLGC,qla for qla-mode on Sun platforms. * Added boot ID NVRAM modification to the set-boot-wwn method.
Version 1.14 11/04/05 * Added support for qla-mode on Sun platforms. Added NVRAM modification words for Fcode parameter byte (fcode-mode) and Boot Port Name/Boot LUN. Including: set-fc-mode, set-boot-wwn, fc-mode@, boot-wwn@, boot-wwn!, and boot-lun@. * Add creation of qla-mode property if the fcode-mode bit is set. * Modify set-address and device-present? to handle #address-cells =2 in qla-mode * Modify set-address & prepare-command to correctly handle 64-bit LUNs. * Cleaned up code. Got rid of unneeded calls to get-id. Made all constants CAPs. * Added login-devices word to login to all fabric devices and return #ports. * Added display-port-db word used by list-wwns and show-children (fabric & loop) * Modified show-fabric-devices to call login-devices and the call get-port-db
Version 1.13 10/28/05 * Asif fixed retry? in scsi.fth to check sense length before copy to IOCB.
Version 1.12 10/10/05 * Fixed issue with multiple initiators on local loop
Version 1.11 (1.10.13) 10/3/05 * Fixed Sun defect CR 6308066 (ER43414) Boot failed from Pyramid targets * Fixed Sun defect CR 6328443 Failed to boot from SE6920/6130 target * Fixed Sun defect CR 6324644 (ER43580) SE6130 LUN information is not shown correctly
Version 1.10.11 09/28/05 * Fixed ER42627: selftest does not perfrom risc-test. * Populate fcp-luns data struct with LUN values in little-endian byte order.
Version 1.10.09 09/26/05 * Fixed ER42883: Getting illegal instruction following a probe-scsi-all. * Fixed ER43041: device name prop creation SUNW or QLGC or fibre-channel. * Fixed ER42627: risc-test causes unknow error. Incuded init-chip before test. * Fixed ER43571: Version property now includes the model string.
Version 1.10 09/13/05 * Included special steps in reset-risc.
Version 1.09 09/12/05 * Released 1.08.06 for test.
Version 1.08.06 09/09/05 * Fixed Sun defect 6309765 - (ER43064 same issue) Adapter information not printed the second time probe-scsi-all is typed. * Fixed Sun defect 6308468 - boot message is not generic. * Fixed Sun defect 6308071 - probe-scsi-all prints incorrect message if no cable connects to a port. * Fixed ER43133 - Displays Error: Unable to get Adapter ID when executing probe-scsi-all. * Fixed ER43135 - The header info indicate ISP2422 instead of ISP2432. * Fixed ER42880 - Mailbox or IOCB interrupt timeout occurred. * Fixed ER42883 - get-portname-db failed. * fcp-targets and show-children would cause login into initiators, and then subsequent scsi cmds to logged-in initiators would fail/timeout. Checked for device type (target/initiator) in PRLI parameters field in response iocb in words get-port-db and login-device, (performed a logout in the case of login-device word (which is fabric topology case)) and returned failure to ensure that no scsi cmds would be issued to initiator devices. * Device name property string dependent on ISP24xx subsystem-device-id for SPARC platform. * Model property dependent on ISP24xx device-id. * Compatible property string prefixed with "pci" (ISP2422) or "pciex" (ISP2432).
Version 1.08.05 07/29/05 * Fix bug in version-prop method for the IBM version (needed a swap).
Version 1.08.04 07/27/05 * Change version-prop method to concatinate long-string & short-verion string Now the date and version number are contained in one single place! * Make the beacon word external. * Add get-id to init-chip to set the topology. Take get-id out of open. * Reorganize the order of methods in ifp.fth * Fix get-sense (retry?) to use the sense data in completion IOCB, if available. * Modify report-luns to accept an "Illegal Request" unit check response. * Move all SCSI related commnads to hacom.fth and rename it "scsi.fth". *
Version 1.08.03 07/12/05 * Change version property string, Add date to the end. * Put LED test "beacon" word back in. It was removed in Version 1.08b6. * Fix login-device call in f-port-fcp-luns method (fcp-luns.fth). * Comment-out call to logout-device in f-port-fcp-luns. (need to stay logged in) * Add release-history.txt file to release package. * Include tokenizer directory in release package, change makefile to use it.
Version 1.08.02 07/05/05 * Fix show-children hang bug when no devices attached, re-wrote show-fabric-devices method. * Create common get-id method to get adapter's ID & portid, new value my-portid. * Add 8048 Async error retry return code (x99) to the do-cur-iocb method. * Create common method, process-async, called by do-cur-iocb and get-mail. * Implement logout-device and logout-devices. (Was a no-op) * Change login-device to return completion-status, clean-up process-login-err. * Changed mailbox command names from isp- to mbc-. * Shortened some messages and made them common. Shortened some value names.
Version 1.08.01 06/28/05 * Change the version string only, for release to Sun.
Version 1.08b7 06/28/05 * Add Serial-Transmit-Parameter mailbox command, set-isp-stp, to init-image. * Add set-slc method to set the Serial-Link-Control parameters in NVRAM. This allows the operator to change the output swing and output pre-emphasis for 1Gb, 2Gb & 4Gb. * Change FCode checksum to use checksum in FCode Header, we will not use our own checksum byte at offset 0xfffc in Flash. The check-fcode method, which is part of selftest, now works on a combined BIOS/FCode/EFI Flash Image. * Add check for "ISP " signature in NVRAM method, nvr-bad?, which is called before setting connection-mode, data-rate and bios-compatibility-mode. If the NVRAM is bad, default values will be used instead. * Fix NVRAM checksum to be the same as Flasutil. (sum words not bytes to = zero) * Added show-bootid & show-model methods to show the corresponding NVRAM values. * Clean up load-image method. * Got rid of set-adapter-loopid. No reference in NVRAM docs, and never used. * Got rid of starting-id stuff. * Changed makefile to not use fiximage or fill128 utility. Use dd cmd instead!
Version 1.08b6 06/20/05 * Shorten version property for luxadm problem. * Add selftest, including: check-nvram, check-fcode, mem-test, risc-test (isp online selftest) and diag-lb (internal, 10-bit, 1-bit, & external loopback) * Fix image size to pad image to 512 byte boundary, and update PCI header value. * Added map-dma to combined dma-alloc and dma-map-in methods. And add unmap-dma to combined dma-free and dma-map-out methods. * Added init-chip method to initialize & re-load FW, equivalent to re-selecting. * Add fiximage.c utility to calculated FCode checksum for Flash images.
Version 1.08b5 05/26/05 * Fix set-fc-address for IBM. Now "Select Boot/Install device" works! * Fix no-data command during IOCB build in prepare-command method. * Added sav-fc method to save a copy of the FCode to RAM at location x4030. * Moved FCode programming methods to a separate file, flash-pgm.fth.
Version 1.08b4 05/23/05 * Fix report-luns method problem when 0 LUNs is returned. * Add SST25LF080A flash support. Add getpid method to check PROM ID.
Version 1.08b3 05/20/05 (First delivery to Qlogic) * Fix BIOS compatible NVRAM parameter bit bug in set-mode method. * The show-children method is now working for loop (nl) and fabric topology, but n-port (point-to-point) is still not supported!
Version 1.08b2 05/19/05 * Change model = QLGC24xx, name = SUNW,qlc. * Add Asif's multiple IOCB interrupt fix. Using rsq-iocb-valid? method.
Version 1.08b1 05/18/05 * Got manual booting on IBM working! Many changes to fcp-luns & fcp-targets. * Fixed SUN/IBM version banner bug. * Modified verbiage in NVRAM mod? word.
Version 1.08x 05/16/05 * Fixed Endian problem w/phandle, now booting in loop topology on the Sun. * Added fcp-targets and fcp-luns methods for IBM platform compatibility.
Version 1.07 05/13/05 * Initial release with booting fabric device working on Sun. * Add ldfcode utility to program FCode at the OK prompt. * Fixed all of the NVRAM parameter set methods. * Combined various pieces of FCode from 2312 & 24xx code bases. qlgc_fw_fc_4g-mb1_90-3-sysx_linux_32-64_chg
IBM HBA 6Gb Controllers BIOS/FW/UEFI Update
Controllers Supported: IBM 6Gb SAS HBA (46M0907) IBM 6Gb SSD HBA (68Y7362) IBM 6Gb Performance Optimized HBA (46M0912)
UEFI Driver Fixes: - Fixed a issue where the controller may not be seen in Linux operating systems. - Fixed issue where HII do not report Multi-LUN devices from external RAID enclosure. - Do not show external RAID LUNs in HII RAID configuration page. - Report NVDATA version consistently in Hex or Decimal.
Version 1.10.04 - Suggested ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.19.00.00 10.00.08.00 7.18.04.02 IBM 6Gb SSD HBA 7.19.00.00 10.00.08.00 7.18.04.02 IBM 6Gb Performance Optimized HBA 7.19.00.00 10.00.08.00 7.18.04.02
- Fixed issue where simple swap configurations with the drives on port 0 will show as bay 4 to 7 and drives on port 1 will show as bay 1 to 3. - Fixed issue where the Build Device Path call to RAID Extended SCSI PassThru Protocol allocates less memory to hold the SAS Device Path + End Device Path casuing a uEFI system hang.
Version 1.10.03 - Suggested ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.19.00.00 10.00.08.00 7.18.04.01 IBM 6Gb SSD HBA 7.19.00.00 10.00.08.00 7.18.04.01 IBM 6Gb Performance Optimized HBA 7.19.00.00 10.00.08.00 7.18.04.01
- Fixed an issue when a hard drive is removed from a RAID10 an existing drive may go offline. - Change the behavior of the LBPWS bit on the logical block provisioning VPD page for SATA drives. - Fixed issue where the SATL's inquiry VPD page 0 does not show support for block limits and logical block provisioning pages.
Note: HII changes may not affect all controllers. Changes for the controller are based on RAID volume support. - HII fix to return EFI_SUCCESS when RETRIEVE Action is given in HII Callback function - HII fix for Write cache disabling fails for SATA HDD/SSD connected to the IT controller. - HII fix for saved Controller Events Filename. - Behvioral change for the way a volume is created in HII. - HII change to Remove Legacy BIOS Enable/Disable option. - Fixed issue where after creating a volume using SATA SSD the Associated Physical Disks always show up as SATA HDD. - Fixed issue where a hotspare could not be created for any volume in the HII browser. - HII fix for the View Physical Disk Properties form where the Serial number of SATA disks were being displaced with a space. - HII fix for the IR help strings displayed when using an IT controller. - Fixed HII issue where a 'Question value mismatch with Option value' error occurs when saying No for creating RAID10/RAID1E volume. - Fixed HII issue where help is not available when having only RAID0 and RAID1 levels in Create Configuration form. - Fixed a problem where the UEFI driver ATA PassThru Protocol is corrupt while trying to access the Mode field. - HII behavior change for 'Manage Foreign Configurations.' - HII change to provide proper extended RAID Levels in help messages based on supported extended RAID Levels.
Note: The following fixes only effect blade systems that support Bofm. - Fixed boot issues in Windows 2008 where after installation in uEFI the os will not boot due to the BuildDevicePath not allocating enough memory for the DevicePathreturned to caller. - Fixed issue with Bofm configurations where the BOFM supplied addresses for external/switch attach Phys are being assigned to the internal/direct attach Phys. - Fixed a Bofm issue where the SAS WWIDs not reverting to Man Page 5 Default when a Blade is moved back to non-BOFM slot.
Version 1.10.01 - Suggested ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.19.00.00 10.00.05.00 7.18.01.05 IBM 6Gb SSD HBA 7.19.00.00 10.00.05.00 7.18.01.05 IBM 6Gb Performance Optimized HBA 7.19.00.00 10.00.05.00 7.18.01.05
Enhancements: - Add support for SATA 6GB drives greater then 2.1TB
Fix: - Fixed numerous hang conditions in HII configurator. - Fixed an issue where RAID1 volume turns to failed state after swapping the primary and secondary drives with each other with hot spares present. - Fixed an issue where Multiple simultaneous drive pulls can lead to an adapter reset. - Fixed an issue where Repeated pulls/re-inserts of physical disk may cause 8109 fault. - Fixed an issue where Roaming of > 2TB SATA volume drives from SAS1 to SAS2 cards, shows the volume drives as bare drives. - Fixed an issue where Activating a foreign volume results in 0x830A fault, if a native FAILED volume with no drive exists. - Fixed isuse where: Resync operation for RAID10 volume stalls at 13% complete. - Fixed a fault condition where a fault 8209 (IFAULT_IR_PD_ELM_NOT_FOUND) may occur when deletinga missing hot spare. - Fixed issiue where a SAS Topology Change List Event may return incorrect NumPhys data - Fixed where a controller sending HOLD after SATA device R_ERR of host to device FIS. - Fixed an issue where 6700 Fault ocurrs after getting a SATA overrun. - Fixed an issue where Disabling one phy causes another phy to be reset. - Fixed an issue where INVALID_STATE reply to SCSI IO Unit Control request to remove a device. - Fixed a Fault 1901 running cable breaker with SATA drivers. - Fixed an issue where a DATA_UNDERRUN (0x0045) IOC status is replied during disk IO. - Fixed a firmware issue where a 8111h fault occurs while activating a foreign volume on an adapter which already has failed volume with all the physical disks missing - Fixed an issue where a SATA: NCQ read command is not completed after a data underrun or overrun. - Fixed a problem when an Update to handle large out of range max host credit setting in manufacturing page 9. - Fixed a Fault 7C35 seen during READ DMA passthrough commands to SATA Drive - Fixed where a SATA: Read command completes with good status after data overrun - Fixed a nissue where the View Volume screen needs more than one ESC key press to exit screen if user has entered Manage HS screen at least once. - Fixed an issue where the Verify command in BIOS CU continues for a drive that is pulled out. - Fixed a BIOS issue where the Config page error is seen when changing enclosures in Controller BIOS. - Fixed an issue in CTRL-C where the BIOS is not checking valid bit in fixed format sense data. - Fixed an issue where the BIOS hangs or asserts NMI and reboots while parsing the SMBIOS entries of some servers. - Fixed an issue where the BIOS CU "Format" and "Verify" fails with some HDDs. - Fixed an issue hwere the SAS2BIOS: CU - SAS Topology screen has hightlight defects when PgDown is used. - Fixed the issue When a IO Adress is not assigned for SAS2 adapter, incorrect Fault is displayed. - Fixed an issue when an Attempt to expand the enclosure in a large topology results in display lag on SAS Topology screen. - Fixed an issue where the Display is irregular while scrolling up/down after selecting SATA-SSD drive as Prferred/Alternate boot device.
Version 1.08.01 - Suggested ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.05.06.00 5.30.03.00 6.00.15.11 IBM 6Gb SSD HBA 7.05.06.00 5.30.03.00 6.00.15.11
Fix: - Addressed problem with event replay code where the enclosurehandle was not being set causing some RHEL 4 device drivers difficultly when looking a the topology.
Version 1.07 - Suggested ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.05.06.00 5.30.02.00 6.00.15.11 IBM 6Gb SSD HBA 7.05.06.00 5.30.02.00 6.00.15.11
- Fixed an issue where some System X servers will log a NMI and PCI error.
Version 1.06a ------------- Contains: Controller BIOS Firmware UEFI Driver IBM 6Gb SAS HBA 7.05.06.00 5.30.01.00 6.00.15.11 IBM 6Gb SSD HBA 7.05.06.00 5.30.01.00 6.00.15.11
IBM ServeRAID BR10il SAS/SATA Controller v2 BIOS and Firmware Update BIOS Version 6.30.02.00, Firmware Version 1.30.10.00 and BSD Version 3.16.00.06
Adapters Supported: IBM ServeRAID BR10il SAS/SATA Controller v2 (49Y4731)
NOTE TO SERVICE - Reference RETAIN #N/A
NOTE: This change history is common between several of the IBM and LSI Basic or Integrated RAID SAS controllers for non-BOFM enabled, uEFI systems. Not all levels were released for all controllers.
BIOS Fixes:: - Fixed an issue where the controller was hanging during initialization when an adapter was hung in reset with insufficient information to reset itself. - Fixed an issue where the SAS MPT BIOS CU reports wrong array size.
BDD Fixes - Removed the "SAS/SATA missing" warning message when SAS and SATA arrays are present on the same controller. Firmware Fix - Addressed issue where 6Gb SATA drives will only negotiate at 1.5Gb/s instead of 3Gb/s. - Fixed issue where SAS/SATA mixing errors will occur when the controller is setup to allow mixing of devices. - Fixed issue with large topology of SATA drives where media errors on a single drive will cause one phy to hang after IOs to other drives start to timeout. - Fixed discovery Error 0x2 in maximum topology with SATA devices, - Addressed issue where Credit would be stuck at zero until controller resets resulting in a phy becoming hung and IO failing. Only occurs with very high IO.
Fixes: - Addressed issue with SATA devices where the drive could go missing for several minutes. - Fixed issue where incorrect release of scatter gather list could cause issues with pending IO to missing devices. - Addressed issue where IOs to a host with a bad drive could fail.
Fixes: - Fixed issue where Target mode responds with incorrect WWID after ports are swapped. - Fixed issue with Incorrect/Unexpected discovery errors on RAID storage enclosures. - Fixed issue where device added events are not sent to the host on RAID storage enclosures. - Fixed issue where it is possible for a Incorrect/Duplicate Device handle to get assigned to a target that is a SSP Initiator. - Fixed problem of the boot order selection not being saved
Fixes: - Changed BIOS text to state an IS Volume creation can be 1 to 10 drives. - Fixed issue with 2TB and above drives where SAS MPT BIOS CU reports wrong array size. - Addressed an issue that will maintain Target IDs for attached devices to an enclosure if the enclosure is removed for a short time.
Fixes: - Fixed an issue where, after running heavy I/O to NCQ enabled SATA drives, the controller may log false data underruns for read or write I/Os. The PHY on which the I/Os were reported as underrun may eventually lock up.
Fixes: - Fixed an issue where Solid State Drives (SSDs) were not seen after a link reset. - Fixed an issue where direct attached SATA drives were not reported missing after they were removed. This could result in degraded or failed volumes being reported as healthy.
Fixes: - Fixed an issue introduced by new functionality in package 2.50. The issue would cause a dual attached device to be hidden from both the direct connection and the expander connection. - Changed the behavior during drive quiescing/un-quiescing to prevent the drive metadata from being unnecessarily updated. - Fixed an issue where drives might go offline during a firmware update, due to I/O timeouts caused by the length of time needed to update the firmware. - Fixed an issue where volumes can become inactive due to the metadata on the drives getting out of synch with NVSRAM.
Fixes: - Fixed an issue where, on certain drives, it was not possible to create a RAID 0. - Fixed an issue which could cause drive ID0 to go offline. - Fixed an issue with SSD hot spares being reported as Orphaned. - Fixed an issue where hot spares could not be created when the first physical disk of a roaming IME volume is missing. - Fixed a memory leak which could occur in verification of hot spare. - Fixed several issues involving creating a volume or hot spare immediately after deleting a volume or hot spare. - Fixed various issues with hot spare reporting. - Fixed an issue where, in a multi-path environment under heavy I/O, an open timeout can cause Linux file systems to become read-only. - Fixed an issue where drives may go offline during a firmware flash under Windows. - Fixed an issue that caused a 0x7600 fault while running heavy I/O to expander attached disks. - Fixed an issue where, when a driver at a certain volume ID is roamed, the volume ID would change on the next reboot. - Fixed an issue which caused a 0x266D fault on reinsertion of a hotspare. - Fixed an issue where a volume cannot be deleted due to foreign metadata from a new drive. - Fixed an issue where a 0x8055 fault could occur upon insertion of drives with deleted metadata. - Fixed a rare issue where drives could go missing under a heavy load. - Fixed an issue where a 0x800F fault may be seen at startup on large topologies. - Fixed an issue that could cause a 0x0B83 fault when a SATA drive failed to initialize. - Fixed an issue where the LED of a critical drive would revert to the pattern for an optimal drive before the drive was truly optimal again. - Fixed an issue where a resync would resume, rather than restart, when a primary drive was removed and re-inserted. - Fixed an issue that could result in 0x6001 faults while running I/O. - Removed some extraneous error messages, which were triggered by reboots or firmware flashes, from the firmware log. - Fixed an issue which cause a 0x266D fault during volume creation. - Fixed an issue which could cause the operating system's file system to become read only in a multi-path environment.
Functionality: - Initial release for: IBM 3Gb SAS HBA v2 - Added support for EFI (Extensible Firmware Interface) based systems. - Enhanced support for SSDs (Solid State Drives). - Implemented support for single drive RAID 0. - Added a new volume status 'Sync Pending' for a volume that could be resynching, but is waiting for the first volume to complete resync. - Added ability to remove an orphaned hot spare when its associated, missing, volume is deleted. - Implemented some LED blink pattern changes to account for new hardware. - Added the ability to enable/disable data scrubbing on SSDs. - Enabled functionality to update drive firmware on disks in a degraded volume (the update must be done via the IBM Online SAS/SATA HDD Update Program, which must also contain a fix to enable this function).
Fixes: - Fixed an issue where, with dual solid state disks (SSD) installed, hard drive 0 goes defunct or disappears or a RAID 1 mirror becomes degraded. - Fixed an issue which slightly degraded performance in a Large Drive Count (LDC) configuration. - Fixed an issue where SATA drives may fail when alternate paths are removed and reinserted in a multipath configuration. - Fixed a condition which caused a 0x1904/0x1903 fault when issuing a TARGET RESET to certain SATA drives. - Fixed an issue where a 0x0800 fault occurs when an inactive or non-optimal volume is deleted. - Changed a resource allocation so that topology and other discovery related events aren't affected when other resources are heavily stressed. - Fixed an issue where, if a volume is removed, then reinserted, into a SAS topology, the volume becomes inaccessible. - Fixed an issue where discovery appears to hang due to multiple Expander Removed events sent for a single expander. - Fixed an which causes an OS not to boot if one of the hard disks in the boot volume is removed. An error similar to "Adapter LSI RAID 0/1 SAS 4P (0) was 1: Disk (0) missing after reboot". - Fixed an issue where continuous 'device added' events would be sent during discovery when a controller is attached to a topology with more end devices than are supported. - Fixed an issue that could cause I/O timeouts or 0x0900/0x1600 faults with SATA drives under heavy I/O load during any memory deallocation. - Fixed an issue where multiple WRITE BUFFER commands may cause a 0x4202 fault. - Fixed an issue where a 0x1904/0x1903 fault may be seen when a duplicate I/O results in a double completion. - Prevented task management timeouts which occurred when the SATA engine was involved with multiple error handling. - Fixed an issue that could cause the Initiator Command queue to become corrupt, resulting in a 0x6001 fault. - Fixed an issue where some error information was lost during Record Not Found media errors. - Fixed an issue with the reporting/retrieval of some LDC statistics. - Fixed an issue which may cause firmware initialization failure when many (more than 50) SATA targets are attached. - Fixed an issue which, in rare cases, could cause a 0x266D fault. - Fixed an issue which could cause a 0x1904 fault when issuing task management requests during heavy IO. - Fixed an issue that caused a break of the MPI spec in a scenario where an end device fails SATA initialization or an expander is out of routing table entries. - Fixed an issue where a virtual PHY is counted multiple times, resulting in the same Bus/Target ID being assigned to two different devices. - Fixed a stack overflow issue which could result as a 0x0900 fault or a fault code 11h during system initialization. - Enabled modification of Write Cache settings for RAID 0 volumes. - Fixed an issue which caused an "Insufficient Resources" response for an MPT RAID Passthrough command. - Fixed an issue where SMP requests are sent through the SMP passthrough, a 0x4203 fault occurs. - Fixed an issue where drives with SMART errors are not detected as volume members. - Prevented a false "Device Not Responding" event during discovery under heavy I/O. - Fixed an issue where an Activity LED would erroneously blink when a raw hard drive was added to a previously occupied slot. - Fixed an issue which could result in media errors at 51% rebuild point when a hot spare is present. - Fixed I/O timeouts and/or invalid SAS Expander Page #0 content which could occur if a bad link caused rapid linkup/linkdown states on a drive. - Fixed an issue which could result in a 0xBADn fault (where n is the PHY number) after a HARD RESET primitive is received. - Corrected an issue where the swap out status of a drive is always set to 0, rather than to a meaningful value. - Fixed an issue where, if a card enters fail-safe mode due to unreadable or unreachable settings, a fault 0x0700 was seen and the card would never enter READY state. - Fixed an issue where a hotspare which was created through the BIOS would not be correctly reported until after a reboot. - Corrected an issue where media errors would cause unnecessary device resets. - Fixed an issue where, if a disk is hot swapped with an incompatible disk, the new disk would incorrectly be assigned the volume ID as its target ID. - Prevented multiple paths from being returned unless multipathing is specifically enabled in NVDATA. - Fixed an issue which results in a 0x6014 fault during discovery in complex topologies. - Corrected an issue where pulling a drive in a volume would caused a 0x801F fault. - Fixed an issue where a 0x6002 fault is encountered in LDC topologies. - Ensured the MPI_EVENT_IR2_RC_PD_REMOVED event is properly reported when a foreign disk is removed. - Fixed an issue which could result in a 0x0800 fault under heavy I/O. - Corrected an issue which results in 0x4E01 fault when processing multiple simultaneous NCQ errors. - Fixed an issue where, if four or more drives are configured as any mix of volumes or hot spares, when you delete the volume, the associated hot spare(s) are correctly deleted, but the physical drives don't reappear in BIOS until after a reboot. - Fixed an issue where, if the same LUN is issued two active resets, the second reset could be completed before the first reset. - Fixed an issue which causes SATA initialization failure if a WRITE command is processed concurrently with a RESET command. The volume would then change to a FAILED state. - Ensured that metadata size is automatically detected by the firmware. - Fixed an issue where the BIOS stops responding if a rebuilding hard drive is removed. - Fixed an issue where 0x7600 faults were encountered when running heavy I/O to cascaded x12 expanders. - Fixed an issue where, with a 1078 chip, a 0x266D fault may occur when hot spare is reinserted. - Corrected an issue where SAS or SATA drives may be reported missing after a target reset to an end device. - Fixed an issue where, if the drive at the volume ID slot is roamed, the volume ID might change on the next reboot. - Fixed an issue where there is a very low probability of experiencing data corruption while under very heavy I/O stress. - Reworked the firmware download function into an asynchronous operation to allow I/O to continue during the process. - Fixed an issue where a direct-attached SEP device will not be assigned an ID or handle which will prevent communication with the device. - Fixed an issue where a direct-attached SEP will be incorrectly assigned TargetID 0.
Functionality: - Implemented various changes to the LED blink pattern for SGPIO. - New functionality to ensure that, if a dual-ported device is connected via both direct and expander attached connections, only the direct connection is hidden when the HideNonzeroAttachedPhyIdentifiers bit is set.
Functionality: - Initial release for: IBM ServeRAID BR10i SAS controller ibm_fw_sraidbr_10il-v2-2_75_linux_32-64_chg
=============================================================================== Emulex NIC Device Driver for Linux ===============================================================================
Linux NIC Device Driver Version: 4.2.389.0
Problems Fixed: - Unloading the driver hangs the system after running IPv6 traffic - Link status messages cleaned up when in Switch Agnostic mode - Miscellaneous network performance issues to improve throughput - Miscellaneous problems related to SRIOV to improve usability - Ethtool wol command displays wol enabled even when disabled - Ethtool speed reported as 10000Mb/s for disabled devices in Switch Agnostic mode
Incremental Interoperability: - RHEL6.3 GA Kernel - Increase default B/W for SRIOV vf's to 10Gb from 100Mb
Known Issues: - SR-IOV configuration section of the Linux NIC Driver Documentation will be modified as follows to improve clarity (noted by << >>):
11. Use the Virtual Machine Manager GUI to attach the VF (step 7 on page 34) to the guest operating system by using the add physical device option.
<< Note 1: If user wants to re-configure an already configured setup, it can be done by removing the attached VF from the respective guest operating system using the remove option after selecting the VF attached. And then attaching another VF (step 11).
Note 2: Consult the documentation for your host operating system for help using the Virtual Machine Manager to attach and detach virtual interfaces. >>
12. Start the RHEL 6.x guest operating system. Once the guest operating system is booted, use the lspci command to confirm the visibility of the OneConnect NIC function. The output shows a OneConnect NIC function, for example: 03:00.0 Ethernet controller: Emulex Corp. Emulex OneConnect 10Gb NIC (be3)
13. The OneConnect Ethernet driver automatically loads with the inbox driver, and creates the network interfaces. Use the ifconfig command to verify that the interface is created.
14. After configuring the network interfaces with proper IP addresses, you can send and receive network traffic from the VM. << (Consult the documentation for your host and guest operating systems for network configuration help). >>
- WOL changes for Linux NIC driver as mentioned in Bug# 24543 - SR IOV UE when attempt to do multiple (3 times) driver load/unload - Speed is 10000Mb/s for Disabled devices in UMC Mode - Incorrect Duplex value is shown for unconnected port of NC552m in Rhel6.1 32bit - SLES 11 SP2 GMC: Enable support for Lnx NIC Driver - SRIOV: When VGT is configured for a VF, ip link show doesn't display it for the VF configured. - RHEL 5.8 GA: Enable support for Lnx NIC Driver - ip link command with vlan = 4095 has toggling effect - ip link command with vlan =0 should remove guest VGT privilege
- SR-IOV: Can't load be2net driver in a VM after the VM has been rebooted - SR-IOV: Unload PF driver with VF driver loaded causes system instability - SR-IOV: VF MAC always gets Emulex OUI - SR-IOV: Partition the limited per port VLAN entries across VFs and PFs - Non Member VLAN packets not received in interface promiscuous mode in BE3 - Avoid CQ full condition in HW - be2net: use RX_FILTER cmd to program multicast addresses - account for skb allocation failures in ethtool stats - Support 60 second delay to Linux NIC driver to allow FAT dump completion on recovery from EEH - Link status is up [ethtool and OCM] when the bandwidth is assign 0 for UMC configuration - Remove msix module parameter - Use V1 version of COMMON_NTWK_LINK_STATUS_QUERY for Lancer. - Emulex: Ethtool failing to update FW - Emulex: Panic in be2net driver in SLES11-SP2-B7 on adapter - TCP ACKs from different connections are getting received in single queue - Multicast filtering feature not working on PPC - Exit of mcast promiscous mode not working - VLAN promiscous mode cannot be set on Lancer - Can't communicate after changing MAC address via VLAN interface - Improper memory accounting in received packets - WOL changes for Linux NIC driver as mentioned in bug - Transparent VLAN tagging feature not working in SR-IOV elx_dd_nic_ibm1206-4_2_389_0_rhel6_32-64_chg
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2 Latest Driver Version: 3.2.0.0 Document Updated: 12/18/2012 Product: Brocade FC HBA / FCoE CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.0.0 New Features and Feature Enhancement: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Fixes and Enhancements: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Version 3.1.0.0 Key features and enhancements supported for the software release 3.1.0.0 include the following:
New Features: - D-port support between Brocade 16Gb HBAs and Brocade 16Gb FC switch platforms with FOS v7.0.1 and later releases - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage - Performance enhancements in Ethernet drivers - Technology Preview support of 1860 HBA on Power PC architecture
Fixes or Enhancements: - Resolved an issue where HCM Agent may not start if BR1860 adapter is configured in NIC mode. - Improved stability with Hyper-V and Teaming configurations. - Resolved I/O errors when running traffic with Brocade HBAs(models 415, 425, 815, 825, and 804), if the server’s PCI max read request size is configured to be 2K or greater with PCI Gen2x8.
Version 3.0.0.0 Fixes and Enhancements: - Added support for Brocade 1860 AnyIO Fabric Adapter (User configurable port mode - FC or NIC or CNA) - Added Fibre Channel 16G Support - Enabled Fabric Assigned Address in Fibre Channel Fabric - Added PF based Virtualization – vHBA - Enhanced CLI, HCM GUI and CIM support in inbox drivers. - Added PF based Virtualization - vNIC - Added iSCSI over DCB Support - Added Multiple Tx Priority Queues Support - Added SNMP Support
Version 2.3.0.3 Fixes and Enhancements: - Enhanced SNIA API to report port speed of 4 and 8Gbps in SNIA format. - Enhanced XIV array interoperability that addresses a data integrity corner case. - Enhanced the transmit path handling in Linux Network Driver to avoid a corner case that could lead to transmit path stall. - Enhanced the Linux Adapter Software installer script to update the initrd with the correct name even when there are multiple copies of the OEM specific initrd(s).
Version 2.3.0.0 Enhancements: - Enabled HP DL120 server to support Boot over SAN with two Brocade HBAs installed. - Improved network driver CPU and performance optimization. - Enabled automated target and LUN discovery of enterprise HDS storage once LUN masking has occurred. - Improved Tivoli interoperability to meet device display requirements.
Version 2.2.0.1 Added capability to handle ADISC frames. Unhandled ADISC use can cause SAN boot failure when booting from IBM storage array.
Version 2.2.0.0 Adds support for bootcode updates to Bladecenter 10G Converged Network Adapters
Version 2.1.0.0 Adds support for bootcode updates to 10G Converged Network Adapters
Version 2.0.0.0 Initial release for 4/8G FC HBAs brcd_dd_nic_bna-3_2_0_0_rhel6_32-64_chg
IBM ServeRAID BR10i SAS Controller BIOS and Firmware Update BIOS Version 6.30.02.00, Firmware Version 1.30.10.00 and BSD Version 3.16.00.06
Adapters Supported: IBM ServeRAID BR10i SAS Controller (44E8689)
NOTE TO SERVICE - Reference RETAIN #N/A
NOTE: This change history is common between several of the IBM and LSI Basic or Integrated RAID SAS controllers for non-BOFM enabled, uEFI systems. Not all levels were released for all controllers.
BSD Fixes: - Fixed an issue where the controller was hanging during initialization when an adapter was hung in reset with insufficient information to reset itself. - Fixed an issue where the SAS MPT BIOS CU reports wrong array size.
BSD Fixes - Removed the "SAS/SATA missing" warning message when SAS and SATA arrays are present on the same controller. Firmware Fixes - Addressed issue where 6Gb SATA drives will only negotiate at 1.5Gb/s instead of 3Gb/s. - Fixed issue where SAS/SATA mixing errors will occur when the controller is setup to allow mixing of devices. - Fixed issue with large topology of SATA drives where media errors on a single drive will cause one phy to hang after IOs to other drives start to timeout. - Fixed discovery Error 0x2 in maximum topology with SATA devices, - Addressed issue where Credit would be stuck at zero until controller resets resulting in a phy becoming hung and IO failing. Only occurs with very high IO.
Fixes: - Addressed issue with SATA devices where the drive could go missing for several minutes. - Fixed issue where incorrect release of scatter gather list could cause issues with pending IO to missing devices. - Addressed issue where IOs to a host with a bad drive could fail.
Fixes: - Fixed issue where Target mode responds with incorrect WWID after ports are swapped. - Fixed issue with Incorrect/Unexpected discovery errors on RAID storage enclosures. - Fixed issue where device added events are not sent to the host on RAID storage enclosures. - Fixed issue where it is possible for a Incorrect/Duplicate Device handle to get assigned to a target that is a SSP Initiator. - Fixed problem of the boot order selection not being saved
Fixes: - Changed BIOS text to state an IS Volume creation can be 1 to 10 drives. - Fixed issue with 2TB and above drives where SAS MPT BIOS CU reports wrong array size. - Addressed an issue that will maintain Target IDs for attached devices to an enclosure if the enclosure is removed for a short time.
Fixes: - Fixed an issue where, after running heavy I/O to NCQ enabled SATA drives, the controller may log false data underruns for read or write I/Os. The PHY on which the I/Os were reported as underrun may eventually lock up.
Fixes: - Fixed an issue where Solid State Drives (SSDs) were not seen after a link reset. - Fixed an issue where direct attached SATA drives were not reported missing after they were removed. This could result in degraded or failed volumes being reported as healthy. - Fixed an issue introduced by new functionality in package 2.50. The issue would cause a dual attached device to be hidden from both the direct connection and the expander connection. - Changed the behavior during drive quiescing/un-quiescing to prevent the drive metadata from being unnecessarily updated. - Fixed an issue where drives might go offline during a firmware update, due to I/O timeouts caused by the length of time needed to update the firmware.
Fixes: - Fixed an issue where, on certain drives, it was not possible to create a RAID 0. - Fixed an issue which could cause drive ID0 to go offline. - Fixed an issue with SSD hot spares being reported as Orphaned. - Fixed an issue where hot spares could not be created when the first physical disk of a roaming IME volume is missing. - Fixed a memory leak which could occur in verification of hot spare. - Fixed several issues involving creating a volume or hot spare immediately after deleting a volume or hot spare. - Fixed various issues with hot spare reporting. - Fixed an issue where, in a multi-path environment under heavy I/O, an open timeout can cause Linux file systems to become read-only. - Fixed an issue where drives may go offline during a firmware flash under Windows. - Fixed an issue that caused a 0x7600 fault while running heavy I/O to expander attached disks. - Fixed an issue where, when a driver at a certain volume ID is roamed, the volume ID would change on the next reboot. - Fixed an issue which caused a 0x266D fault on reinsertion of a hotspare. - Fixed an issue where a volume cannot be deleted due to foreign metadata from a new drive. - Fixed an issue where a 0x8055 fault could occur upon insertion of drives with deleted metadata. - Fixed a rare issue where drives could go missing under a heavy load. - Fixed an issue where a 0x800F fault may be seen at startup on large topologies. - Fixed an issue that could cause a 0x0B83 fault when a SATA drive failed to initialize. - Fixed an issue where the LED of a critical drive would revert to the pattern for an optimal drive before the drive was truly optimal again. - Fixed an issue where a resync would resume, rather than restart, when a primary drive was removed and re-inserted. - Fixed an issue that could result in 0x6001 faults while running I/O. - Removed some extraneous error messages, which were triggered by reboots or firmware flashes, from the firmware log. - Fixed an issue which cause a 0x266D fault during volume creation.
Functionality: - Enhanced support for SSDs (Solid State Drives). - Implemented support for single drive RAID 0. - Added a new volume status 'Sync Pending' for a volume that could be resynching, but is waiting for the first volume to complete resync. - Added ability to remove an orphaned hot spare when its associated, missing, volume is deleted. - Implemented some LED blink pattern changes to account for new hardware. - Added the ability to enable/disable data scrubbing on SSDs. - Enabled functionality to update drive firmware on disks in a degraded volume (the update must be done via the IBM Online SAS/SATA HDD Update Program, which must also contain a fix to enable this function).
Fixes: - Fixed an issue which could cause the operating system's file system to become read only in a multi-path environment. - For the 1064 option for System x3200 M2, x3250 M2, or x3350, fixed an issue where the amber LED would not light up on a defunct drive.
Fixes: - Fixed an issue where, with dual solid state disks (SSD) installed, hard drive 0 goes defunct or disappears or a RAID 1 mirror becomes degraded. - Fixed an issue which slightly degraded performance in a Large Drive Count (LDC) configuration. - Fixed an issue where SATA drives may fail when alternate paths are removed and reinserted in a multipath configuration. - Fixed a condition which caused a 0x1904/0x1903 fault when issuing a TARGET RESET to certain SATA drives. - Fixed an issue where a 0x0800 fault occurs when an inactive or non-optimal volume is deleted. - Changed a resource allocation so that topology and other discovery related events aren't affected when other resources are heavily stressed. - Fixed an issue where, if a volume is removed, then reinserted, into a SAS topology, the volume becomes inaccessible. - Fixed an issue where discovery appears to hang due to multiple Expander Removed events sent for a single expander. - Fixed an which causes an OS not to boot if one of the hard disks in the boot volume is removed. An error similar to "Adapter LSI RAID 0/1 SAS 4P (0) was 1: Disk (0) missing after reboot". - Fixed an issue where continuous 'device added' events would be sent during discovery when a controller is attached to a topology with more end devices than are supported. - Fixed an issue that could cause I/O timeouts or 0x0900/0x1600 faults with SATA drives under heavy I/O load during any memory deallocation. - Fixed an issue where multiple WRITE BUFFER commands may cause a 0x4202 fault. - Fixed an issue where a 0x1904/0x1903 fault may be seen when a duplicate I/O results in a double completion. - Prevented task management timeouts which occurred when the SATA engine was involved with multiple error handling. - Fixed an issue that could cause the Initiator Command queue to become corrupt, resulting in a 0x6001 fault. - Fixed an issue where some error information was lost during Record Not Found media errors. - Fixed an issue with the reporting/retrieval of some LDC statistics. - Fixed an issue which may cause firmware initialization failure when many (more than 50) SATA targets are attached. - Fixed an issue which, in rare cases, could cause a 0x266D fault. - Fixed an issue which could cause a 0x1904 fault when issuing task management requests during heavy IO. - Fixed an issue that caused a break of the MPI spec in a scenario where an end device fails SATA initialization or an expander is out of routing table entries. - Fixed an issue where a virtual PHY is counted multiple times, resulting in the same Bus/Target ID being assigned to two different devices. - Fixed a stack overflow issue which could result as a 0x0900 fault or a fault code 11h during system initialization. - Enabled modification of Write Cache settings for RAID 0 volumes. - Fixed an issue which caused an "Insufficient Resources" response for an MPT RAID Passthrough command. - Fixed an issue where SMP requests are sent through the SMP passthrough, a 0x4203 fault occurs. - Fixed an issue where drives with SMART errors are not detected as volume members. - Prevented a false "Device Not Responding" event during discovery under heavy I/O. - Fixed an issue where an Activity LED would erroneously blink when a raw hard drive was added to a previously occupied slot. - Fixed an issue which could result in media errors at 51% rebuild point when a hot spare is present. - Fixed I/O timeouts and/or invalid SAS Expander Page #0 content which could occur if a bad link caused rapid linkup/linkdown states on a drive. - Fixed an issue which could result in a 0xBADn fault (where n is the PHY number) after a HARD RESET primitive is received. - Corrected an issue where the swap out status of a drive is always set to 0, rather than to a meaningful value. - Fixed an issue where, if a card enters fail-safe mode due to unreadable or unreachable settings, a fault 0x0700 was seen and the card would never enter READY state. - Fixed an issue where a hotspare which was created through the BIOS would not be correctly reported until after a reboot. - Corrected an issue where media errors would cause unnecessary device resets. - Fixed an issue where, if a disk is hot swapped with an incompatible disk, the new disk would incorrectly be assigned the volume ID as its target ID. - Prevented multiple paths from being returned unless multipathing is specifically enabled in NVDATA. - Fixed an issue which results in a 0x6014 fault during discovery in complex topologies. - Corrected an issue where pulling a drive in a volume would caused a 0x801F fault. - Fixed an issue where a 0x6002 fault is encountered in LDC topologies. - Ensured the MPI_EVENT_IR2_RC_PD_REMOVED event is properly reported when a foreign disk is removed. - Fixed an issue which could result in a 0x0800 fault under heavy I/O. - Corrected an issue which results in 0x4E01 fault when processing multiple simultaneous NCQ errors. - Fixed an issue where, if four or more drives are configured as any mix of volumes or hot spares, when you delete the volume, the associated hot spare(s) are correctly deleted, but the physical drives don't reappear in BIOS until after a reboot. - Fixed an issue where, if the same LUN is issued two active resets, the second reset could be completed before the first reset. - Fixed an issue which causes SATA initialization failure if a WRITE command is processed concurrently with a RESET command. The volume would then change to a FAILED state. - Ensured that metadata size is automatically detected by the firmware. - Fixed an issue where the BIOS stops responding if a rebuilding hard drive is removed. - Fixed an issue where 0x7600 faults were encountered when running heavy I/O to cascaded x12 expanders. - Fixed an issue where, with a 1078 chip, a 0x266D fault may occur when hot spare is reinserted. - Corrected an issue where SAS or SATA drives may be reported missing after a target reset to an end device. - Fixed an issue where, if the drive at the volume ID slot is roamed, the volume ID might change on the next reboot.
Functionality: - Implemented various changes to the LED blink pattern for SGPIO. - New functionality to ensure that, if a dual-ported device is connected via both direct and expander attached connections, only the direct connection is hidden when the HideNonzeroAttachedPhyIdentifiers bit is set.
Note: - The multi-path read only fix that was added in version 2.45 is not present in 2.50. It is reintroduced in version 2.51.
Fixes: - Fixed an issue where there is a very low probability of experiencing data corruption while under very heavy I/O stress. - Reworked the firmware download function into an asynchronous operation to allow I/O to continue during the process. - Fixed an issue where a direct-attached SEP device will not be assigned an ID or handle which will prevent communication with the device. - Fixed an issue where a direct-attached SEP will be incorrectly assigned TargetID 0.
Fixes: - Fixed an issue where, in a setup with cascaded expanders, a timeout occurred during PortEnable after an adapter initialization. - Increased several preset maximum values to allow all devices to be seen in large topologies. - Fixed an issue where SATA initialization would hang in a multiple initiator environment. - Fixed an issue that could result in a system hang when an active-active MUX that did not support NCQ was detected in the topology. - Fixed several issues which would cause doorbell faults when using SATA drives. Faults include 0x6001, 0x0B85, or 0x6212. - Fixed an issue where "Persistent Table Full" messages were seen even with persistent mapping disabled. - Fixed a SATA initialization error which could occur when I/O was sent to the drive shortly after the DEVICE ADD event. - Fixed a discovery error that was seen when rebooting initiators under heavy I/O in a multi-initiator environment. - Fixed an issue that could cause a 0x7A02 doorbell fault in a 1078-based complex topology environment. - Fixed an issue which caused doorbell fault 0x4203 when an expander is disconnected during discovery. - Fixed a multipathing issue where devices were not seen after a secondary path was removed and readded quickly. - Fixed an issue where, under heavy I/O, the message indicating discovery completion could be lost. - Fixed multiple issues that were specific to multipathing. - Fixed issues where a controller would hang after firmware or BIOS flash. - Fixed an issue that could cause loginfo 0x31123000 during heavy I/O. - Fixed various issues that could cause doorbell faults 0x4104, 0x0B85, 0x266D, 0x2100, 0x4202, or 0x7711. - Fixed an issue where SATA initialization would fail if the drive did not support write caching. - Fixed an issue where, when logs were generated for a passive path, the enclosure handle and slot information for the active path were stored in the logs. - Fixed an issue where all disks become inaccessible if a SATA logical loop is introduced into a topology with SAS drives. - Fixed an issue which caused BIOS timeouts which resulted in the boot device not being found. - Fixed an issue where, during certain MPT BIOS activity, the system BIOS could not read the MPT BIOS, resulting in a "no bootable device" error. - Fixed an issue where, if translated SCSI commands where sent to a SATA drive the I/O would hang. - Fixed an issue where a hard reset sent to one initiator in a multi-initiator environment could cause a cascade of hard resets through the environment. - Fixed an issue where a corrupted sector in a primary volume was not being correctly restored with the correct data from the secondary volume. - Fixed an issue where, if the secondary drive is cold swapped during a volume resync, the resync is not resumed on system start. - Fixed an issue where the driver temperature info is not sent for SCT enabled drives. - Fixed an issue where the second path is not being hidden when a non-volume drive is inserted in a volume ID slot. - Fixed an issue where, during initialization, the SAS BIOS displays 'Adapter Malfunctioning!' Fault 13. - Prevented Device Missing Delay replies when DevMissingTimeout and IoDelayTimeout are disabled. - Fixed and issue where, when inserting a new drive into the topology while I/O is running, I/O to existing drives may experience a delay of ~600msec. - Fixed an issue where the execution of a command in CFGGEN following execution of a command without a ‘noreset’ switch causes controller to hang. - Fixed an issue where firmware update of an online SATA drive would fail. - Fixed several issues where, when detecting whether a device is an HDD or SDD, the device type was detected incorrectly. - Fixed an issue where physical disk firmware download commands were being rejected. - Fixed an IOC hang that could be caused by a SCSI INQUIRY command. - Fixed an issue where, in a multipath environment, a degraded RAID volume with a missing disk is rebooted, it may re-sync to a non-RAID disk. - Fixed a SATA specific issue where a doorbell fault 0x1903 or 0x1904 was seen when hot-plugging an active drive. - Fixed a large topology issue where I/O to the SAS drives times out after a bus reset. - Fixed an issue where, when the last device in a volume is missing, the volume may be calculated as the wrong media type. This will prevent hotplug and failover from working correctly. - Fixed an issue where the volume ID changes after removing the drive at a roamed volume ID. - Fixed an issue where, when a volume's disk is swapped and starts to resync, a controller reset (reboot) may result in either the volume losing a disk that was previously in the volume, and/or the wrong disk reported as the primary. - Fixed an issue where discovery would fail when a 1078 controller is connected to a JBOD with dual-I2C SEP functionality.
Functionality: - Initial release for: IBM BladeCenter LS22 and LS42 onboard LSI 1064e controller - Fixed the ability for the BIOS configuration utility to create hotspares with SSD (Solid State Drive) devices. - Enhanced SATA I/O performance for NCQ drives. - Allowed the host to set the name of a RAID volume. - Added ability to retrieve SATA drive temperature through "Information Exception". - For SGPIO, turned on the fault LED when an IR volume member is detected as missing. - Added ability to specify bus/target ID & slot mapping for direct-attached disks. - Expanded the ability for the backplane to define the sideband interface method (I2C/SGPIO). This was previously enabled for 1078, now it is enabled for 1064 and 1068 as well. - Several changes the blink LED patterns. ibm_fw_sraidbr_10i-2_75_linux_32-64_chg
=============================================================================== Emulex 16GB FC Firmware Package ===============================================================================
Firmware Version: 1.1.21.9
Incremental Interoperability: - Later Operating System support. Refer to IBM ServerProven for specifics - IBM Server machine types. Refer to IBM ServerProven for specifics
Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches
Multi-boot Image for 8Gb FC HBAs Release Notes version MB_2.32-4
This software license applies only to QLogic customers. QLogic Corporation. All rights reserved.
Table of Contents
1. Version 2. 8Gb BIOS 3. 8Gb EFI 4. 8Gb FCode 5. Trademarks 6. Notices 7. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and release details that apply to the multi-boot package for 8Gb HBAs, version MB_2.32-4. This package is a compressed file that contains:
* BIOS version 2.16 * FCode version 3.13 * EFI version 2.27 * Firmware version 5.03.06
Rev 1.00 Jan.20, 2005 Initial release. Rev 1.01 Feb.18, 2005 Added code to put Port ID of device in IOCB. Rev 1.02 Mar.28, 2005 Added support for Serial Link Control. Addded code to display slot, bus number and function in CTRL-Q utility. Rev 1.03 Apr.18, 2005 Fixed bug when no drives attached and connected to switch. Added code to reset ISP if ISP is paused when ISR is called. Rev 1.04 June 8, 2005 Fixed bug in CTRL-Q utility that caused adapter id to be displayed at invalid id's. Added code to set Write Protect in Flash Status reg. Fixed bug in CTRL-Q utility where EAX reg was being corrupted by timer interrupt routine. Fixed bug in setting up LUN field in IOCB. Fixed bug in not setting port ID when connected to a switch. Rev 1.05 Sept 27, 2005 Changed code to suppress padding firmware version with leading zero's. Fixed bug in setting data direction flags in IOCB for 'seek command'. Changed code to not count device if device disabled by system BIOS. Fixed bug in setting flash Write Protect. Rev 1.06 Oct. 13, 2005 Fixed bug where anykey could invoke Fastutil. Rev 1.09 Nov. 22, 2005 Changed buffer request size to 2056 bytes for 'Report Luns' command. Fixed bug where GAN_NXT IN_ID was not always being set to zero causing GAN_NXT to fail. Rev 1.10 an. 31, 2006 Added check for optional boot mode flag to allow code to configure 1 drive/port when enabled. Bit 6 of host parameters in NVRAM is set to enable this mode. Fixed bug when Spinup-Delay and link is down. Added code to not display Data Rate option in CTRL-Q for QME2462. Rev 1.11 Feb. 7, 2006 Added support for interrupt polling. This option is controlled by bit 7 of NVRAM Host Parameters and by new Advanced Settings option in CTRL-Q. Rev 1.12 Feb. 21, 2006 Changed format of PnP string to display when Opt Boot Mode enabled in NVRAM. Added check for ELS reject status from Login IOCB. Rev 1.13 Apr. 04, 2006 Fixed bug in not always setting port id for logout IOCB. Changed code to support up to 16 adapters and 16 drives. Rev 1.14 Apr. 17, 2006 Changed code to ignore CLP '_hss' string. Rev 1.15 Apr. 20, 2006 Added code to wait for Login to complete when login pending status detected. Rev 1.16 May. 4, 2006 Fixed bug in not setting up Luns/Target in CTRL-Q. Added code to support Restore Default option CLP string (PCI3.0 BIOS only). Changed timeout value waiting for Linkup status from 6 seconds to 23 seconds. Rev 1.17 June 29, 2006 Added support for restoring defaults using CLP string (Pci3.0 only). Optimized code waiting for Linkup status. Added code to use Memory Map I/O for PCI express. Added code to check for correct Max Payload Size on QLE2464. Rev 1.18 July 19, 2006 Added code to load Nec switch port 1 and 2 pci config regs offset 68h with port 0 config offset 54h value. Fixed bug where task attributes in IOCB type 7 were not always being initialized. Rev 1.19 July 24, 2006 Fixed bug in CTRL-Q utility configuring Luns using Report Luns data when lun list has more lun entries after lun 255. Rev 1.20 Aug 2, 2006 Added code to support QLE2xx. Rev 1.21 Aug 24, 2006 Fixed bug in CTRL-Q cursor positioning for some user input displays. Rev 1.22 Sept 11, 2006 Added support for 'exit' CLP string. Changed CLP string to support new format: 'PermanentAddresses' was changed to 'PermanentAddress. Rev 1.23 Oct 16, 2006 Fixed bug in not setting rc_hba when different adapter types installed in system. Rev 1.24 Nov 29, 2006 Removed Extended Error Logging option from CTRL-Q. Removed code to use Memory Map I/O for PCI express. Rev 1.25 Dec 12, 2006 Added code so that set Defaults only to restores factory setting when value was modified by CLP string Rev 1.26 Dec 20, 2006 Fixed issue with the handling of CLP WWNN string. Also added code to always set firmware nodename optiom when set Default CLP is received. Rev 1.27 Feb. 26, 2007 Added support for Set Capabilities CLP string. Added code to load PLX switch port 1 and 2 pci config regs offset 68h with port 0 config offset 54h value (this is same code used for NEC switch). Rev 1.28 Apr. 12, 2007 Added code to check if need to restore HBA default portname. Added check for command fail status after login cmd. Restored code to read block 0 to determine drive geometry. Added NVRAM option (host_params bit 8) to enable support for HP boot order. Fixed bug in handling CLP Set Capabilities data. Rev 1.29 May. 22, 2007 Restored CTRL-Q Lun per Target option and changed text from 'Boot order' option to 'Controller order'. Rev 2.00 Dec. 03, 2007 Added support for ISP2532. Rev 2.01 Jan. 17, 2008 Added support for 1Gb data rate for 4Gb HBA. Rev 2.02 Feb. 18, 2008 Changed code to clear 'Disable Serdes' flag for CLP string Restore Default. Rev 2.03 Mar. 12, 2008 Added support for ISP8423. Added code to support new CLP 'set capability' spec. Rev 2.04 Mar. 23, 2008 Changed code to not used bit 13 of Host parameters. This avoids potential confict with inbox driver. Rev 2.05 Jun. 3, 2008 Added code to allow 2 min for link to come up when spinup delay enabled. Added code to poll for keyboard status. Removed external Loopback test option for ISP8432. Added check if IO support valid. Added check to CLP set_capablity string for the correct HBA port. Rev 2.06 Jun. 18, 2008 Added support for new CLP 'set capability' serial link spec for ISP2532. Rev 2.07 Sept. 3, 2008 Added additional error message for Verify Disk utility when device does not support SCSI cmd 2fh. Add support for Extended HBA CLP strings. Rev 2.07.6 Sept. 12, 2008 Fixed bug with 'restore netport defaults' when restoring NPIV's. Added code to reset ISP before accessing NVRAM the first time. Rev 2.07.8 Oct. 22, 2008 Added support for IDT PCIe switch Fixed bug in restoring NPIV after updating with CLP. Rev 2.08 Oct. 30, 2008 Removed TEST ONLY from BIOS banner. Rev 2.09 Dec. 02, 2008 Added code to save some pci data. Added new option to Advanced Option menu in CTRL-Q for Virtual Fabric Enable/Disable. Rev 2.10 Feb. 24, 2008 Added support for ISP8001 Added check for INT Polling before updating interrupt controller(PCI3.0) Fixed bug where eax register was being corrupted in nvram_config routine. Removed option in CTRL-Q for Virtual Fabric Enable. Fixed cosmetic bug in displaying selectable boot lun in CTRL-Q utility. Rev 2.11 Apr. 28,2009 Fixed issue with setting up Init FW MB command for using Extended Init Control Block Added option in CTRL-Q utility for Primary FCF VLAN ID for ISP8001 HBA. Added code to check version field of Extended ICB. Added code to correctly identify pci switch on 4 port HBA's. Changed code to suppport Loopback mode with new version of FW. Rev 2.12 May, 15,2009 Changed code to handle HSS CLP vendor id 3 same as vendor id 2. Rev 2.13 July 16, 2009 Added code to save backup copy of VPD/NVRAM data. Rev 2.14 Oct 9, 2009 Changed code to use FS segment register instead of GS in find_device routine. Change code to preserve MSB of WWPN Set Capablity CLP when updating WWPN/WWNN. Rev 2.15 Nov 23, 2009 Added code to handle 'About FW' mailbox command timeout. adapter. Rev 2.16 Mar 16, 2010 Fixed bug in not setting Write protect for single port adapter.
Driver Name : Fibre Channel Driver for UEFI Version : 2.27 Date : 05/9/2010 OS platform : N/A FW version : See MultiBoot release notes for FW version. Efiutil Version : 2.86
Table of Contents I. Overview II. Enhancements III. Bug Fixes IV. Known Issues V. Additional Information
I. Overview
The following document provides details of the Fibre Channel UEFI driver version 2.27, Efiutil version 2.86.
II. Enhancements
None
III. Bug Fixes
Driver: * Removed Extra character and NULL string message from HII. (ER71174, ER71175) * Add support for 8GB data rate for 25xx family in HII form. (ER71118) * Add fix in driver to avoid to print driver messages on splash screen during system boot up. (ER71099) * Add support for HII Protocol. (ER55486) * Added fix to allow W2K8 boot from local disk when target is mapped in passive path. (ER70069) * Added fix to diplay firmware version info correctly in HII "Adapter info" menu. (ER71412) * Display error message in HII form if invalid HBA parameter value is set (Execution Throttle). (ER71533) * Fixed a bug that caused VPD version numbers to be displayed wrong. (ER70907) * Add fix for NULL string message displayed on Hx5 system. (ER71771) * The "Enable Loop ID" bit in the HII menu is now set correctly. (ER71885) * Rename "Reconnect and Exit from Main Menu" HII entry to "Exit from Main Menu".
Efiutil: * Add fix to avoid, overwriiting of orignal SERDES file, if user give wrong command. (ER69941) * Added fix to avoid, "unaligned reference fault", while updating flash. (ER69793) * Add support, to ignore locked fileds while updating firmware area. (ER69531) * Add fix to display firmware version correctly. (ER71468) * Add fix to display new firmware version correctly while updating multiboot image. (ER71468) * Add support for 82xx family in Adapter list. (ER69230)
IV. Known Issues
* In the HII menus, Adding/Deleting a Target/LUN will require a reboot for changes to take effect.
V. Additional Information
* Efiutil and the EFI Driver are a matched set. Always make sure that Efiutil and the EFI Driver are from the same release package.
version 3.13 03/26/10 * Change REV_LEVEL in rev_level.m4 from 3.13b9 to 3.13. Offical Release.
version 3.13b9 03/24/10 * Remove Explicit logout to fabric(FLOGO) in close-hardware, put in v3.13b3. * Restructure fcode source files. Add: isp-init.fth, p3-init.fth, mailbox.fth, properties.fth, structs.fth, regs-isp.fth, regs-p3.fth, utils.fth.
Version 3.13b8 03/09/10 * Add Parameter 1 debug display on login IOCB faliure if debug-logi? is set. * Add force-open-ok? test flag in open method. Default = true(no real change). * Change get-to-params to set boot-wt = 8 secs if boot-wait-time is disabled. * Fix bug in VPD fetch, introduced in v3.13b1. vpd-buf increased to 512 bytes. * Change cbuff back to non instance buffer. Instance has no effect on buffer:.
Version 3.13b7 03/04/10 * Remove Hard-RICS-reset from reset-risc method. Causes problems on QMI2582. * Remove Eddy test= Reset RX-Serdes after 5 secs wait for in isp-fw-ready?. * Make old-sb (old sec-buf) an instance value. Problem on M3000 (ER70453).
Version 3.13b6 03/02/10 * Add Reset RX-Serdes after 5 secs wait for in isp-fw-ready?. Plus add debug.
Version 3.13b5 03/01/10 * Add more debugging in isp-fw-ready?. Print fw-state each time in get-state. * Change getnum to use the 'accept' word and make cbuff an 'instance' buffer:.
Version 3.13b4 02/24/10 * Fix Explicit logout-device IOCB to include the ISP PortID and Port WWN. * Changed debug? flags: 4000= Got-R2H-intr, 2000= IOCB-Dump, 800= FW-Ready-wait.
Version 3.13b4 02/22/10 * Fix Explicit logout-device IOCB to include the ISP PortID and Port WWN.
Version 3.13b3 02/19/10 * Use OpenBIOS Toke Tokenizer to make isp2500/8100/8200. isp2400 uses SUN toker. * Add Sun-Style-Checksum option OpenBIOS Toke for all SUN isp2500/8100/8200. * Add Implicit logout-all and Explicit logout to fabric in close-hardware. * Add setting the FW ICB link-down-NOS/OLS value for isp2400/2500 (ER67806).
Version 3.13b2 02/11/10 * Change set-boot-wait-time to not affect link-down-to (timeout) for Fujitsu. * Change login-devices to not logout with FC_Initiators. * Change logout-device to use implicit Logout, not explicit. (Fix P3P problem)
Version 3.13b1 02/05/10 * Change set-boot-wait-time to be entered/display in decimal, not hex(Fujitsu). * Added OpenBIOS 'toke' Tokenizer to makefile. Now you can make either version.
Version 3.12 01/11/10 * No change to isp2500, fixed SSDID for Sun (SUNW,qlc) CNA QLE8142.
Version 3.11 12/11/09 * No change to isp2500, added support for Sun (SUNW,qlc) CNA QEM8152.
Version 3.10 12/02/09 * Change the name of the top level Fcode file from isp2xxx.fth to ispxxxx.fth. * Change makefile to include the creation of P3+ isp8200.xxxx.fc binaries.
Version 3.09 10/26/09 * Change REV_LEVEL in rev_level.m4 from 3.09b1 to 3.09. Offical Release.
Version 3.09b1 10/22/09 * Fix Node-Name-Option bit preservation in restore-default-settings. ER68181.
Version 3.08 10/19/09 * Change REV_LEVEL in rev_level.m4 from 3.08b1 to 3.08. Offical Release. * Remove patch of PCI header image size byte at offset 0x2c from init version.
Version 3.08b1 10/14/09 * Fix default WWNN & WWPN preservation in restore-default-settings. ER67924. * Fix stack bug when link down. Introduced in v3.05 set-phandle word. ER67926. * Add standard properties. Use m4 utility to automaticly create date string. * Add file rev_level.m4 which has the revision level strings only. * Remove "SFP state: Unknown" message (.isp) if the adapter is IBM mezz card. * Add FCoE & 4Gb IBM mezz cards QMI8142 QMC2462 QMI3472 QMI2472 to imezz? word. * Change messages "Login failed" to "Login Abort". "Error Subcode" to "Subcode". * Re-structure Flash/NVRAM access fnv-wd@/! words for the Netxen P3 integration. * Add 'make nx3031' to makefile for Netxen P3. #ifdef P3 used for delineation.
Version 3.08b1 09/25/09 * Add standard properties. Use m4 utility to automaticly create date string. * Add file rev_level.m4 which has the revision level strings only. * First version with some support for the Netxen P3 CNA.
Version 3.07 09/08/09 * Change version string from 3.07b2 to 3.07. Offical Release for IBM and SUN.
Version 3.07b2 09/04/09 * Fix read-cap16-cmd. Used when the LUN size is >2TB (i.e. #blocks > 32-bits). * Fix disk-test to work with large (>2TB) LUNs, where the LBA > 32-bits.
Version 3.07b1 08/28/09 * Remove command retry when 8048 AEN is received. Caused DMA error found by IBM. This was an old workaround put in vers1.08b2, before IOCB timeouts were set.
Version 3.06 08/19/09 * Change version string from 3.06b6 to 3.06. Offical Release for IBM. * Fix qlgc-debug? option for IBM. Use find-method on IBMs and $find on SUNs.
Version 3.06b6 08/18/09 * Add option for qlgc-debug? in nvramrc. If the diag-switch? is true, then the debug? flag is set is set to the value of qlgc-debug?.
Version 3.06b5 08/18/09 * Add lba64 large disk capability (read-blocks64 write-blocks64) for SUN only. * Add support for QEM3572, SSDID = x172, for SUN only. * Add mbox1 & mbox2 display for 8048 interrupt if debug-asyc? flag (01) is on.
Version 3.06b4 08/13/09 * Fix bug in IBM fcp-luns method for the Controller LUN-0 check, lun0-check.
Version 3.06b3 08/12/09 * Check Inquiry Qualifier field of Controller LUN-0 in IBM fcp-luns method.
Version 3.06b2 08/10/09 * Add more IOCB debugging, Add Erase Response-Queue in mapmem. Had stale data.
Version 3.06b1 08/08/09 * Add more debugging for IOCBs, dma-map-in/out, & wait-for-interrupts.
Version 3.05 08/04/09 * Change version string from 3.05b2 to 3.05 Offical Release for IBM.
Version 3.05b2 08/03/09 * Fix set-fc-address issue found with IBM ioinfo. PortID was not getting set. * Re-structure devicepresent.fth. Add set-phandle to set obp-target & obp-portid
Version 3.05b1 07/31/09 * Fix multiple close issue found with IBM ioinfo utility.
Version 3.04 07/22/09 * Change version string from 3.04b2 to 3.04 Offical Release. * Add alloc-sec-buf & free-sec-buf words with debugging messages.
Version 3.04b2 07/21/09 * Add "ibm,write-supported" property to disk child node, as per IBM's request. * Removed VPD validation from validate-nvram due to bug in update utilities. * Do not reallocate sec-buf when revert-wwns is called within the isp-probe. The revert-wwns method now calls my-revert-wwpn and my-revert-wwnn.
Version 3.04b1 07/20/09 * Fix enab-nvr-acc to alloc sec-buf & add disab-nvr-acc for BOFM words.ER66671. * Make use_backup? an "instance value", so it will always initialize as false.
Version 3.03 07/13/09 * Change version string from 3.03b2 to 3.03 Offical Release. * Added console messages when validate-nvram finds corruption & copies a sector. Version 3.03b2 06/22/09 * Change validate-nvram to validate both ports on Dual-port HBAs at probe time. * Fix init-flt-offsets to mask FLT attributes. Now it finds FW & Feature-key.
Version 3.03b1 06/12/09 * Add NVRAM backup Sector. Add validate-nvram at probe time to fix corruption.
Version 3.02 05/06/09 * No change, affected Schultz ISP8100 Fcode only.
Version 3.01 04/23/09 * No change, affected Schultz ISP8100 Fcode only.
Version 3.00 04/21/09 * No change, affected Schultz ISP8100 Fcode only.
Version 3.00b8 04/01/09 * Add unsupported message for set-connection-mode for IBM QMI2572/3572/2582.
Version 3.00b7 03/31/09 * Change set-data-rate menu to remove 8Gb selection if the HBA is a QMI2572.^M
Version 3.00b6 03/04/09 * Change boot-wait-time to start timer(fw-ready-wait) in isp-fw-ready? method. * Fix pgm-sec (pgm-params) to set cd-base = ld-base. ISP2500 & isp8100 only. * Change fix-rbios to check nvr-bad? before copying nvram to RAM.
Version 3.00b5 02/25/09 * Change link-down-timeout to boot-wait-time if bootwait-enable flag is true. * Changed era-code (used in ldfcode) to use /code to determine #secs to erase. * Add set-cd-base+siz (used for ldfcode) to replace set-ld-base & set-/dlc. * Fix function number mask, func#, on ISP2500 only.
Version 3.00b4 02/11/09 * Change all Flash offsets used by FLT from constants to values. ISP2500 only.
Version 3.00b3 01/21/09 * Add back IOBAR(x10) to reg property for ISP2500 that was removed in v2.04b1. This fix was in version 2.04 but was inadvertently dropped in version 3.00b1
Version 3.00b2 01/08/09 * Added set-boot-wait-time commnad for all 4 & 8Gb HBAs/CNAs. Add NVRAM Fcode 2-byte parameter, boot-wait-time, at ofs x15a & enable-bit(x20) at ofs x158. This was requested by Fujitsu, for disks that take longer to come online. * Added set-fc-sunid to set the NVRAM sunid bit. For internal use only.
Version 3.00b1 12/19/08 * Added more SCSI sense debugging. * Reworked interrupt service routines with more debugging.
Version 2.05 03/26/09 - Delayed release to IBM = v3.00b4 wo/boot-wait-timeout * Change set-data-rate menu to remove 8Gb selection if the HBA is a QMI2572. * Change all FLT Flash offset parameters from constants to values ISP2500 only. Version 2.04 12/03/08 * Change version string from 2.04b2 to 2.04 Offical Release. * Add debug message to init-flt-offsets " Init FLT offsets" for ISP2500 only. * Add back IOBAR(x10) to reg property for ISP2500 that was removed in v2.04b1.
Version 2.04b2 12/02/08 * Add FLT and FDT Flash access methods for ISP2500 only. * Remove set-bootid, set-boot-wwn, & releated qla only words from IBM version. * Added IBM debugging to BOFM words and set debug?=C00 if diag-switch is true. * Added max-payload bridge fix for 4-port QMI2564 HBA. Used Gil's method. * Fix get-mail to handle Response-Queue interrupts (stat=13) & add debugging. * Removed all Serial-Link-Control access/modify words from ISP2500 only.
Version 2.04b1 07/23/08 * Fix open to always return -1. Returning link-down fw-state fails on Serengetti * Remove IO-BAR (x10) from reg property for ISP2500 or later.
Version 2.03 06/30/08 * Change version string from 2.03b1 to 2.03 Offical Release.
Version 2.03b1 06/06/08 * Use complete NVRAM values for fwopt2 and fwopt3 in fw-init, initialize ICB. * ADD Sun QLE2560 and QLE2562 support, which have SSDIDs of 0x0170 and 0x0171.
Version 2.02 05/07/08 * Change version string from 2.02b3 to 2.02 (Offical Release). * Fix load-image to return error status so you can exit on failure. * Remove stop-fw from isp-probe method. It did nothing since FW is not loaded.
Version 2.02b3 04/17/08 * Change compatible property(IBM) to append to existing property, if it exists. * Change all references in the Fcode of 'HBA' to 'Adapter' (for QLE8000 CNA).
Version 2.02b2 04/14/08 * Fix compatible prop for IBM. Return DDDD value back to DevID in strings: pciVVVV,DDDD.SSSS.ssss.RR & pciVVVV,DDDD.SSSS.ssss. DDDD was = SSDevID.
Version 2.02b1 03/27/08 * Fix blank lines in list-wwns for set-boot-wwn command in qla-mode. ER59591. * Change the d-mbox (dump-mailbox) word to use the .4z data format macro.
Version 2.01 03/27/08 * Change version string from 2.01b2 to 2.01 (Offical Release). * Version 2.01b2 had no changes for ISP2500 8Gb HBA Fcode.
Version 2.01b1 03/03/08 * Add debug display of SFP state (mbox 2) if debug-fwait? (x800) is set. * Fix selftest mem-siz = x20000 (128KB) on IBM CFFe/CFFx mezz cards.
Version 2.00 02/15/08 * Change version string from 2.00b17 to 2.00 (Offical Release).
Version 2.00b17 02/07/08 * Modify ldfcode again to skip copy of WWN and checksum to BIOS-defaults area.
Version 2.00b16 02/05/08 * Modify ldfcode to copy all BIOS-defaults plus copy Model & DID to header. * Fix login-devices to return #ports, including non-target ports. This fixes Sun Bug ID 6645537, ER58525, where LUNs were not listed when Emulex present.
Version 2.00b15 01/29/08 * Fix target login problem with McData switch by adding GID_PT command. ER58769. * Modify ldfcode to Flash both Functions when file=Fcode-only on the ISP2500. * Modify ldfcode to poke BIOS default area of the MB-image with Model# & SSID.
Version 2.00b14 01/15/08 * Fix restore-default-setting to skip SSDID, OEM Specific Area, Feature Mask, and Model# copy to NVRAM. Also add revert-wwns on IBM. ER58465 & ER58509. * Replace load-stub-fw with stop-fw mbox command for PCIe 2400 HBAs. Firmware vers 4.00.25 or greater stop-fw command will do the same thing as stub FW. * Fix IBM BOFM bug where the default WWPN is lost if a new WWPN is written twice
Version 2.00b13 12/21/07 * Separate 2400/2500 Fcode into two isp2400/isp2500 binary output files. Remove isp2500? & use #ifdef ISP2500. Resulting in smaller 37KB image size. * Add use-cdb16? flag which is set in read-capacity if the target supports Large LBA. 16-byte CDBs are used only if use-cdb16? is set & LBA > 32-bits. ER58285. * Fix "chrp" string in papr-compliant? word (IBM BOFM support). * Change write-wwnn word to check for new-wwnn=0 (IBM BOFM support). * Add enab-nvr-acc to all 6 BOFM external words so they work on unopened dev.
Version 2.00b12 12/10/07 * Remove reset-risc in 2500 nvr-wd! & ldfcode that was put in 2.00b11.ER58002. There were too many side-effects from resetting the RISC during Flash writes. Now if FW is stopped, writes to Flash will fail before the Flash is erased. * Add init-chip? to sns-command & logout-devices for recovery from link-down. * Put ifp-abort back into wait-for-risc-int, which was taken out in vers 1.23.
Version 2.00b11 12/05/07 * Move clearing of flags link-up?, done-fw-init? port-updated? to reset-risc. This was for isp2500 set-boot-wwn failure because FW was stopped. ER58139.
Version 2.00b10 11/30/07 * Add reset-risc to 2500 nvr-wd! in case the FW is stopped. ER58002. * Change 2500 flash-cfg! (Flash config write) to use write-ram Mbox command. This will prevent the Flash erase from working if there's a mailbox problem.
Version 2.00b9 11/28/07 * Fix find-image to check for last-image bit and exit loop if found. ER57989. * Add reset-risc to ldfcode for the case when isp2500 FW was stopped. ER58002. * Fix init-fw problem. If NVRAM is blank, FW Option word-1 is not set in ICB.
Version 2.00b8 11/21/07 * Make BOFM support words external in IBM version. * Change my-wwnn@ to return WWNN based on current adapter WWPN. (IBM version) * Fix stop-risc bug. Clear done-fw-init? flag before calling mail. ER57926. * Fix 8Gb nvr-word! stack bug. It was not returning success? flag. ER57977.
Version 2.00b7 11/12/07 * Remove 'ibm,' from the BOFM support words for IBM. Also update property. * Add check-managed-wwn which checks for PAPR-compliant & san_wwn string in root prop " ibm,managed-address-types" and then reverts WWNs if necessary.
Version 2.00b6 10/18/07 * Changed makefile to create separate isp2400 & isp2500 images(PCI header only). * Fix drate-val (default Auto Data-Rate value) w/o shift for selftest. * Fix n-port topology device-present problem. obp-portied was not getting set. * Add stop-risc word (whch issues a Stop FW mbox command) for isp2500. the stop-risc is issued on close instead of the isp2400 load-stub-fw. * Add back architecture check (wrong-arch?) of PCI header DEVID during flashing. * Add rd-ram-wd and wr-ram-wd mailbox commands for debugging purposes. * Add BOFM support for the IBM version Fcode.
Version 2.00b5 09/24/07 * Combined 2400/2500 Fcode into a single binary output isp2x00 file. Use isp2500? word instead of #ifdef ISP2500. Resulting image size is now 38KB. * Changed Connection Mode & Data Rate debug messages during FW initialization.
Version 2.00b4 09/18/07 * Shrink code wherever possible. Remove unused words and shorten value names. * Fix find-fc method to add Func0 bc0_ofs. Otherwise it checksums Func1-fcode.
Version 2.00b3 09/07/07 * Add reset-risc to reopen-hardware method when init_link?=0, for INIT version.
Version 2.00b2 09/06/07 * Fix set-data-rate for ISP2500 to remove the 1 Gb/sec selection. ER56564. * Fix selftest to always use Auto-negoiate data-rate. ER56565. * Fix open for selftest to return OK status when link-down on a reopen. ER56566.
* Remove load-stub-fw method for ISP2500. A reset-risc is all that is needed.
* Change ISP2500 ld-code & ver-code methods to always use mbox DMA commands. * Fix version number in PCI header. Should be 2.00.
Version 2.00b1 08/28/07 * Add 2500 support with major change in NVRAM and Flash utilities.
* Change VPD address & data registers to be different values for ISP2500. * Add extra setting for 8Gb/sec in set-data-rate.
Started with ISP2400 Code Base, Version 1.27 08/21/07 qlgc_fw_fc_8g-mb2_32-4_linux_32-64_chg
Firmware Version 2.01a3 (w/ 5.12a5 Universal Boot Code)
New Features
* Enhanced timeout notifications for processing abort failures.
Problems Fixed:
1. All multi-abort I/Os are returned on the same ring from which the ABORT_MXRI command was received.
2. Changed the TRCV response in the abort state to CMD RJT to enable the TRSP to be processed.
3. Corrected an issue with blocked TSEND operations.
4. Corrected a buffer leak issue with RRQ exchanges.
5. Corrected an issue where the TRCV IOCB was de-queued improperly causing a XFR_RDY flood.
6. Corrected an issue where the OXID field was not loaded in the XRI_ABORTED IOCB.
7. Corrected an issue in recognizing whether an EEPROM is present.
Dependencies: - The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly.
1. 118933 Fixed an issues booting when more than 8 ports are present in the system and fixed an adapter display issue when more than 8 ports are present in the systems 2. 118933 Fixed issues installing and booting O/Ss on ports greater than 8. 3. 121923 Fixed issues installing and booting O/Ss on ports greater than 8. 4. 122286 Fixed some boot time screen display issues.
(2) OpenBoot version 3.10a3
This version of OpenBoot supports FC-AL, Private loop, Public loop, and Fabric Point to Point. Also, it supports multi-initiators and multi-LUNs (0 through 4055)
Problems fixed, features added or other updates:
1. Unrelated to IBM
(3) EFIBoot version 4.12a12
The current EFI (Extensible Firmware Interface) Boot provides 64-bit System boot capability through the use of the EFI Shell. This EFIBoot supports EFI Specification 1.10 and EFI Source Code version 1.10.14.61.
Problems fixed, features added or other updates:
1. Only certain OEM HBAs will locate PlatformToDriverConfigurationProtocolGuid. Others just skip and continue processing 2. UEFI2.3 Hii Configuration Utility changes 3. HII Browser Save option does not work
1. CR105423 - On a port connected to a 3PAR "MBOD" cage, the test runs IO to the disk drives and issues a "controlport offline" command to offline the port while IO is running.
2. CR111194 - While doing target side cable pull testing with Block Guard (T10) Enabled we observed that adapter is not sending RSCN to AIX.
3. CR111625 - *IBM defect 775960 - HBQ ring index pointers?
5. CR111928 - 3PAR - LR with port and subsequent FLOGI failing.
Dependencies: - The corresponding FC Storport device driver and OneCommand Manager Core-kit (management) will need to be installed for this package to function properly. elx_fw_fc_ibm1206-2_01a9_linux_32-64_chg
=============================================================================== Emulex iSCSI Device Driver for Linux ===============================================================================
Linux iSCSI Device Driver Version: 4.2.398.0
Problems Fixed: - Cleaned up a cosmetic problem with warning messages during driver compile from source
- LUN is not getting detected for OEM CNA in SLES 11 SP2 64 bit OS - ioctl semaphore deadlock when running load/unload loop with target - SLES 11 SP2 GMC: Enable support for Lnx iSCSI Driver - RHEL 5.8 GA: Enable support for Lnx iSCSI Driver
- Emulex: Warning messages seen while building Emulex drivers on RHEL platform - Unable to load be2iscsi driver during iSCSI boot OS install - Modprobe be2iscsi hangs when system with max targets login - be2iscsi unload hangs the system - fw rebooted on 1st mbox cmd after driver load > unload > load - Failed to initialize iscsi driver - need to define DMA_32BIT_MASK / DMA_64BIT_MASK in Linux kernel 3.x.x elx_dd_iscsi_ibm1206-4_2_398_0_rhel6_32-64_chg
Broadcom NetXtreme TG3 Linux Driver
Version 3.124c
Copyright (c) 2010 - 2012 Broadcom Corporation All rights reserved
commit cac83e53917ebc058066eb98023c11fdaa2262dc Author: Michael Chan Date: Sun Jul 29 19:15:45 2012 +0000
tg3: Update version to 3.124
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 0f566b208b41918053b2e67399673aaec02dde5d Author: Michael Chan Date: Sun Jul 29 19:15:44 2012 +0000
tg3: Fix race condition in tg3_get_stats64()
Spinlock should be taken before checking for tp->hw_stats.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 091f0ea30074bc43f9250961b3247af713024bc6 Author: Michael Chan Date: Sun Jul 29 19:15:43 2012 +0000
tg3: Add New 5719 Read DMA workaround
After Power-on-reset, the 5719's TX DMA length registers may contain uninitialized values and cause TX DMA to stall. Check for invalid values and set a register bit to flush the TX channels. The bit needs to be turned off after the DMA channels have been flushed.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 10ce95d6ef36c65df7dcd3b8fcf86913f8b298bd Author: Michael Chan Date: Sun Jul 29 19:15:42 2012 +0000
tg3: Fix Read DMA workaround for 5719 A0.
The workaround was mis-applied to all 5719 and 5720 chips.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 8151ad576d34a5ec1f1068edf25f3b7c47f6edab Author: Michael Chan Date: Sun Jul 29 19:15:41 2012 +0000
tg3: Request APE_LOCK_PHY before PHY access
to prevent PHY access conflict with APE firmware.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
The driver currently skips setting this flag if the VPD contains the firmware version string. We fix this by separating the probing of NCSI from the reading of the NCSI version string. The APE_HAS_NCSI flag is needed to properly read sensor data.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
tg3: add device id of Apple Thunderbolt Ethernet device
The Apple Thunderbolt ethernet device is already listed in the driver, but not hooked up in the MODULE_DEVICE_TABLE(). This fixes that and allows it to work properly.
Signed-off-by: Greg Kroah-Hartman Acked-by: Michael Chan Signed-off-by: David S. Miller
commit b7abee6ef888117f92db370620ebf116a38e3f4d Author: Matt Carlson Date: Thu Jun 7 12:56:54 2012 +0000
tg3: Apply short DMA frag workaround to 5906
5906 devices also need the short DMA fragment workaround. This patch makes the necessary change.
Signed-off-by: Matt Carlson Tested-by: Christian Kujau Signed-off-by: David S. Miller
tg3: Avoid panic from reserved statblk field access
When RSS is enabled, interrupt vector 0 does not receive any rx traffic. The rx producer index fields for vector 0's status block should be considered reserved in this case. This patch changes the code to respect these reserved fields, which avoids a kernel panic when these fields take on non-zero values.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
If port 0 of a 5717 serdes device powers down, it hides the phy from port 1. This patch works around the problem by keeping port 0's phy powered up.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 7ae5289017e5ed5514b2603d157fb54c058a3c82 Author: Michael Chan Date: Wed Mar 21 15:38:33 2012 +0000
tg3: Fix RSS ring refill race condition
The RSS feature in tg3 hardware has only one rx producer ring for all RSS rings. NAPI vector 1 is special and handles the refilling of the rx producer ring on behalf of all RSS rings. There is a race condition between these RSS NAPIs and the NAPI[1]. If NAPI[1] finishes checking for refill and then another RSS ring empties the rx producer ring before NAPI[1] exits NAPI, the chip will be completely out of SKBs in the rx producer ring.
We fix this by adding a flag tp->rx_refill and rely on napi_schedule()/ napi_complete() to help synchronize it to close the race condition.
Update driver version to 3.123.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 2fae5e3670a666039e6f2fd63e1a5d320c71b913 Author: Michael Chan Date: Sun Mar 4 14:48:15 2012 +0000
tg3: Fix poor tx performance on 57766 after MTU change
GRC reset causes the read DMA engine to go into a mode that breaks up requests into 256 bytes. A PHY reset is required to bring it back to the normal mode.
Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 6541b806b5f267eda8f127bb7f5fec4e7e4db995 Author: Michael Chan Date: Sun Mar 4 14:48:14 2012 +0000
tg3: Add memory barriers to sync BD data
for weak memory model architectures to ensure that the chip will DMA valid BD data.
Signed-off-by: Michael Chan Reviewed-by: Benjamin Li Reviewed-by: Matt Carlson Signed-off-by: David S. Miller
commit c441b456767357322dbc14b55bdc7da0051d0d98 Author: Michael Chan Date: Sun Mar 4 14:48:13 2012 +0000
tg3: Fix jumbo loopback test on 5719
Loopback on 9K packet fails because the chip has a DMA limit of 4K. The loopback test logic uses a single BD for simplicity. Fix it by reducing the jumbo packet size to the DMA limit.
Signed-off-by: Michael Chan Reviewed-by: Benjamin Li Reviewed-by: Matt Carlson Signed-off-by: David S. Miller
commit 65ec698d1368fc64d0b93fb703783d25ec550577 Author: Matt Carlson Date: Tue Feb 28 23:33:37 2012 +0000
tg3: Fix tg3_get_stats64 for 5700 / 5701 devs
tg3_get_stats64() takes tp->lock when dealing with non-serdes bcm5700 and bcm5701 devices. However, functions that call tg3_halt() have already acquired tp->lock. When tg3_get_stats64() is called in tg3_halt(), deadlock will occur.
This patch fixes the problem by separating the stat gathering code into a new tg3_get_nstats() function. tg3_get_stats64() is recoded to call this function and take tp->lock. The code that takes tp->lock in tg3_calc_crc_errors() has been removed. Function signatures have been cleaned up too.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit c71013597d49c7ca8bb5049f0c7873df2643fad5 Author: Matt Carlson Date: Wed Feb 22 12:35:20 2012 +0000
tg3: Clear RECOVERY_PENDING with reset_task_cancel
If an error happens in the tx completion thread, tg3_reset_task will be scheduled and TX_RECOVERY_PENDING will be set. The TX_RECOVERY_PENDING flag causes tg3_poll[_msix] to return early before doing much of its work. Tg3_reset_task() gets canceled when the configuration of the device is changing, which always results in a chip reset. When this happens, the TX_RECOVERY_PENDING flag may be left set, which would unnecessarily hinder tg3_poll from doing work. This patch fixes the problem.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit 9e056c0320fafc03dc170772d8562e3142ed1778 Author: Matt Carlson Date: Mon Feb 13 15:20:17 2012 +0000
tg3: Update copyright
This patch updates the copyright dates in the tg3 driver.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit 2855b9fe416e55d01a1946b142d87abd4cceb6ea Author: Matt Carlson Date: Mon Feb 13 15:20:14 2012 +0000
tg3: Remove unused link config code
When tg3 devices are shutdown, the driver uses the TG3_PHYFLG_IS_LOW_POWER flag to enable a static phy configuration. Any attempt to use the link configuration variables is dead code. This patch removes such code.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 422782249927e887a4c032d1d7e1f59de281ecbb Author: Matt Carlson Date: Mon Feb 13 15:20:11 2012 +0000
tg3: Fix NVRAM page writes on newer devices
On newer devices, the hardware expects the NVRAM address register to be written only once per NVRAM page. To do otherwise causes NVRAM corruption. This patch fixes the problem.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit 3198e07fd64aa8c3a38dda33bcc0f44265eb581e Author: Matt Carlson Date: Mon Feb 13 15:20:10 2012 +0000
tg3: Fix copper autoneg adv checks
When checking the autoneg advertisements, the driver failed to include the master and master enable bits for the bcm5701. This patch fixes the problem.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit b546e46f5c9f19a921d6f62db80f2e9371bc0558 Author: Matt Carlson Date: Mon Feb 13 15:20:09 2012 +0000
tg3: Fix stats while interface is down
If the tg3 interface is down, the driver will return ethtool stats uninitialized. This patch zeroes out the destination stat buffer in such a case.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 3906969189a409e590a51b18c86a92d0506c9372 Author: Matt Carlson Date: Mon Feb 13 15:20:08 2012 +0000
tg3: Disable new DMA engine for 57766
A bug was found in the new DMA engine for the 57766. This patch disables it, which causes the device to fallback to the old DMA engine.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit c5665a538da6b887a5096358a12527785506e5ac Author: Matt Carlson Date: Mon Feb 13 10:20:12 2012 +0000
tg3: Move transmit comment to a better location
This patch moves a comment in the transmit path to a better location.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit a5a1195559f2e20bd975f58e50f53ebe84d5cca6 Author: Eric Dumazet Date: Mon Jan 23 01:22:09 2012 +0000
tg3: fix ipv6 header length computation
tg3_start_xmit() makes the wrong assumption for TSOV6 that skb->head doesnt include any payload data.
if (skb_is_gso_v6(skb)) hdr_len = skb_headlen(skb) - ETH_HLEN;
This is not true anymore after commit f07d960df3 (tcp: avoid frag allocation for small frames)
We should instead use : skb_transport_offset(skb) + tcp_hdrlen(skb)
Its also true for IPv4
Signed-off-by: Eric Dumazet CC: Matt Carlson CC: Michael Chan Signed-off-by: David S. Miller
commit c3b5003b628d8e373262bee42c7260d6a799c73e Author: Matt Carlson Date: Tue Jan 17 15:27:23 2012 +0000
tg3: Fix single-vector MSI-X code
Kdump kernels leave MSI-X interrupts (as setup by the crashed kernel) enabled. However, kdump only enables one CPU in the new environment, thus causing tg3 to abort MSI-X setup. When the driver attempts to enable INTA or MSI interrupt modes on a kdump kernel, interrupt delivery fails.
This patch attempts to workaround the problem by forcing the driver to enable a single MSI-X interrupt. In such a configuration, the device's multivector interrupt mode must be disabled.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit 3db1cd5c05f35fb43eb134df6f321de4e63141f2 Author: Rusty Russell Date: Mon Dec 19 13:56:45 2011 +0000
net: fix assignment of 0/1 to bool variables.
DaveM said: Please, this kind of stuff rots forever and not using bool properly drives me crazy.
I merely installed coccinelle, read the documentation and took credit.
Signed-off-by: Rusty Russell Signed-off-by: David S. Miller
commit 90415477bf1356f72acc34063ff52441fc10a754 Author: Matt Carlson Date: Fri Dec 16 13:33:23 2011 +0000
tg3: Make the RSS indir tbl admin configurable
This patch adds the ethtool callbacks necessary to change the rss indirection table from userspace. Should the number of interrupts change (e.g. across a close / open call, or through a reset) and any one of the indirection table values fall out-of-range, the driver will reset the indirection table to a default layout.
[Integrated many suggestions made by Ben Hutchings.]
Changes since v3
* Removed TG3_FLAG_SUPPORT_MSIX checks at the start of tg3_get_rxfh_indir() and tg3_set_rxfh_indir().
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit bcebcc468a6bcd3820fe9ad36b34220563efc93a Author: Matt Carlson Date: Wed Dec 14 11:10:01 2011 +0000
tg3: Break out RSS indir table init and assignment
This patch creates a new device member to hold the RSS indirection table and separates out the code that initializes the table from the code that programs the table into device registers.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit f88788f0da6326cbcaa837e12c8c074027891f07 Author: Matt Carlson Date: Wed Dec 14 11:10:00 2011 +0000
tg3: Use mii_advertise_flowctrl
This patch replaces tg3's internal tg3_advert_flowctrl_1000T function with mii_advertise_flowctrl provided by the kernel headers.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit 55086ad95d740577def0b4e6ecc2c0ae9b0d6dec Author: Matt Carlson Date: Wed Dec 14 11:09:59 2011 +0000
tg3: Add 57766 ASIC rev support
This patch adds support for the 57766 ASIC revision.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit a4cb428d31e11af1662e19c6fab9133c0f7a0eda Author: Matt Carlson Date: Wed Dec 14 11:09:58 2011 +0000
tg3: Make the TX BD DMA limit configurable
The 57766 ASIC rev will impose a new TX BD DMA limit on the driver. This patch prepares for 57766 support by making the tx BD DMA limit tunable.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit 4f272096054b6154e31e850f192eef5782f156c6 Author: Matt Carlson Date: Wed Dec 14 11:09:57 2011 +0000
tg3: Enable EEE support for capable 10/100 devs
There are some devices in the 57765 ASIC rev that are EEE capable. Unfortunately the EEE setup code only gets executed if the device is gigabit capable. This patch fixes the problem.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Benjamin Li Signed-off-by: David S. Miller
commit efab79c5c3bf830a41b2f737146a9b70c0e13f44 Author: Matt Carlson Date: Thu Dec 8 14:40:18 2011 +0000
tg3: Update version to 3.122
This patch updates the tg3 version to 3.122.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Ben Hutchings Signed-off-by: David S. Miller
commit 4a2db503c57f7223d851dc7ab8cefca614e0d98a Author: Matt Carlson Date: Thu Dec 8 14:40:17 2011 +0000
tg3: Return flowctrl config through ethtool
This patch changes the driver to return the flow control configuration rather than the flow control status through the ETHTOOL_GPAUSEPARAM ioctl.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Ben Hutchings Signed-off-by: David S. Miller
commit 859edb2631c31813e63cbff7a81ced4f853b63ed Author: Matt Carlson Date: Thu Dec 8 14:40:16 2011 +0000
tg3: Track LP advertising
This patch adds code to track the autonegotiation advertisements of the link partner and report them through ethtool.
Signed-off-by: Matt Carlson Signed-off-by: Ben Hutchings Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit e2bf73e75aef01d93f569c4625b0d7f50f3e1031 Author: Matt Carlson Date: Thu Dec 8 14:40:15 2011 +0000
tg3: Integrate flowctrl check into AN adv check
This patch integrates tg3_adv_1000T_flowctrl_ok() into tg3_copper_is_advertising_all() and renames the function tg3_phy_copper_an_config_ok().
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Ben Hutchings Signed-off-by: David S. Miller
commit 92feeabf3f673767c6ee4cfc7fc224098446c1c1 Author: Matt Carlson Date: Thu Dec 8 14:40:14 2011 +0000
tg3: Save stats across chip resets
Tg3 has a place to store stats, but doesn't really use it. This patch modifies the driver so that stats are saved across chip resets and gets cleared across close / open calls.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Reviewed-by: Ben Hutchings Signed-off-by: David S. Miller
commit 0e6c9da35ef774109a1b5740144c9d442bd5a5b5 Author: Matt Carlson Date: Thu Dec 8 14:40:13 2011 +0000
tg3: Remove ethtool stats member from dev struct
This patch removes the ethtool stats member from the tg3 device structure.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Reviewed-by: Ben Hutchings Signed-off-by: David S. Miller
commit 298376d3e8f00147548c426959ce79efc47b669a Author: Tom Herbert Date: Mon Nov 28 16:33:30 2011 +0000
tg3: Support for byte queue limits
Changes to tg3 to use byte queue limits.
Signed-off-by: Tom Herbert Acked-by: Eric Dumazet Signed-off-by: David S. Miller
commit 2c55a3d08ade44a778c182c220a7907ec65d5fb8 Author: Matt Carlson Date: Mon Nov 28 09:41:04 2011 +0000
tg3: Scale back code that modifies MRRS
Tg3 normally gets a performance boost by increasing the PCI Maximum Read Request Size (MRRS) to 4k. Unfortunately, this is causing some problems on particular hardware platforms. This patch removes all code that modifies the MRRS except for one case.
As part of a solution to fix an internal FIFO problem on the 5719, the driver artificially capped the MRRS to 2k for the entire 5719, and later 5720, ASIC revs. This was overly aggressive and only really needed to be done for the 5719 A0. In the spirit of the rest of this patch, the driver will only reprogram the MRRS for this device if the value exceeds the 2k cap.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit cf9ecf4b631f649a964fa611f1a5e8874f2a76db Author: Matt Carlson Date: Mon Nov 28 09:41:03 2011 +0000
tg3: Fix TSO CAP for 5704 devs w / ASF enabled
On the earliest TSO capable devices, TSO was accomplished through firmware. The TSO cannot coexist with ASF management firmware though. The tg3 driver determines whether or not ASF is enabled by calling tg3_get_eeprom_hw_cfg(), which checks a particular bit of NIC memory. Commit dabc5c670d3f86d15ee4f42ab38ec5bd2682487d, entitled "tg3: Move TSO_CAPABLE assignment", accidentally moved the code that determines TSO capabilities earlier than the call to tg3_get_eeprom_hw_cfg(). As a consequence, the driver was attempting to determine TSO capabilities before it had all the data it needed to make the decision.
This patch fixes the problem by revisiting and reevaluating the decision after tg3_get_eeprom_hw_cfg() is called.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit e348c5e7de4a759a94eed4d0303ba81a4939f8b9 Author: Matt Carlson Date: Mon Nov 21 15:01:20 2011 +0000
tg3: Add MDI-X reporting
This patch adds MDI-X state reporting.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit fa6b2aae6ab5ae1ce4b65c1872477c4b794d338e Author: Matt Carlson Date: Mon Nov 21 15:01:19 2011 +0000
tg3: Restrict large prod ring cap devices
Future devices may or may not be capable of supporting larger rx producer rings. This patch changes the code so that this flag is set on an ASIC rev to ASIC rev basis. Also, this patch changes a place where the LRG_PROD_RING_CAP flag was not controlling how the rx standard producer ring size was set.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit 513aa6ea39adfc9daf5b4bc33b49008733c3eb51 Author: Matt Carlson Date: Mon Nov 21 15:01:18 2011 +0000
tg3: Adjust BD replenish thresholds
The BD replenish thresholds for the 57765 and newer ASIC revs are a little strict. They were tuned for a mode that is currently unused. This patch relaxes the thresholds so that they are set to values more inline with the resources available.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
commit f3791cdf33e7d21515de25f5ead0eca38f85ca11 Author: Matt Carlson Date: Mon Nov 21 15:01:17 2011 +0000
tg3: Make 1000Base-X FC resolution look like 1000T
This patch changes tg3's 1000Base-X flow control resolution to look like the 1000Base-T flow control resolution code.
Signed-off-by: Matt Carlson Signed-off-by: David S. Miller
Commit 28011cf19b (net: Add ethtool to mii advertisment conversion helpers) added a helper function ethtool_adv_to_mii_100bt() and tg3_copper_is_advertising_all(), tg3_phy_autoneg_cfg() were modified to use this. Before that commit, ethtool to mii advertisement conversion was done wrt speed, but now pause operation is also taken account. So, in tg3_copper_is_advertising_all(), below condition becomes true and this makes link up fails.
if ((adv_reg & ADVERTISE_ALL) != all_mask) return 0;
To fix this add ADVERTISE_ALL bit and operation to cap speed, and change default advertisement not including ADVERTISED_Pause.
Reported-by: Eric Dumazet Signed-off-by: Hiroaki SHIMODA Signed-off-by: David S. Miller
commit 9205fd9ccab8ef51ad771c1917eed7b2f2225d45 Author: Eric Dumazet Date: Fri Nov 18 06:47:01 2011 +0000
tg3: switch to build_skb() infrastructure
This is very similar to bnx2x conversion, but simpler since no special alignement is required, so goal was not to reduce skb truesize.
Using build_skb() reduces cache line misses in the driver, since we use cache hot skb instead of cold ones. Number of in-flight sk_buff structures is lower, they are more likely recycled in SLUB caches while still hot.
Signed-off-by: Eric Dumazet CC: Matt Carlson CC: Michael Chan CC: Eilon Greenstein Signed-off-by: David S. Miller
commit 37f07023d30708b5da091fe6d6be9b60783c6d82 Author: Matt Carlson Date: Thu Nov 17 14:30:55 2011 +0000
net: Change mii to ethtool advertisement function names
This patch implements advice by Ben Hutchings to change the mii side of the function names to look more like the register whose values they convert. New LPA translation functions have been added as well.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 28011cf19b75df9d3f35489a7599a97ec0b3f1a0 Author: Matt Carlson Date: Wed Nov 16 18:36:59 2011 -0500
net: Add ethtool to mii advertisment conversion helpers
Translating between ethtool advertisement settings and MII advertisements are common operations for ethernet drivers. This patch adds a set of helper functions that implements the conversion. The patch then modifies a couple of the drivers to use the new functions.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
Signed-off-by: Michał Mirosław Signed-off-by: David S. Miller
commit 68aad78c5023b8aa82da99b47f9d8cf40e8ca453 Author: Rick Jones Date: Mon Nov 7 13:29:27 2011 +0000
sweep the floors and convert some .get_drvinfo routines to strlcpy
Per the mention made by Ben Hutchings that strlcpy is now the preferred string copy routine for a .get_drvinfo routine, do a bit of floor sweeping and convert some of the as-yet unconverted ethernet drivers to it.
Signed-off-by: Rick Jones Signed-off-by: David S. Miller
commit 5ae7fa06bb90421bc63f1f1e56ab241b49bc7b91 Author: Matt Carlson Date: Fri Nov 4 09:15:05 2011 +0000
tg3: Update version to 3.121
This patch updates the tg3 version to 3.121.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 5b1906241905d9bd1abe920854b3d43c2b9c85e1 Author: Matt Carlson Date: Fri Nov 4 09:15:04 2011 +0000
tg3: Eliminate timer race with reset_task
During shutdown, it is impossible to reliably disable the timer and reset_task threads. Each thread can schedule the other, which leads to shutdown code that chases its tail.
To fix the problem, this patch removes the ability of tg3_reset_task to schedule a new timer thread. To support this change, tg3_timer no longer terminates itself, but rather goes into a polling mode.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit db21997379906fe7657d360674e1106d80b020a4 Author: Matt Carlson Date: Fri Nov 4 09:15:03 2011 +0000
tg3: Schedule at most one tg3_reset_task run
It is possible for multiple threads in the tg3 driver to each attempt to schedule a run of tg3_reset_task(). The multiple tg3_reset_task executions could all wind up on the same queue (and execute serially) or wind up on the queues of another processor (which could execute in parallel). Either scenario is not what was truly desired.
This patch adds a new flag, TG3_FLAG_RESET_TASK_PENDING, and uses it to determine whether or not to schedule another run of tg3_reset_task(). With the new flag comes two new functions to facilitate scheduling and descheduling of tg3_reset_task().
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 9dc5e342703948ea7b086d063c85c0e79dac8149 Author: Matt Carlson Date: Fri Nov 4 09:15:02 2011 +0000
tg3: Obtain PCI function number from device
This patch adds code to attempt to obtain the PCI function number from the device rather than accept the number handed by the kernel. In pass-through scenarios, the function number handed by the kernel may not reflect the true function of the device.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 5bc09186deba2a016b60aa3923fc0e42838ce877 Author: Matt Carlson Date: Fri Nov 4 09:15:01 2011 +0000
tg3: Fix irq alloc error cleanup path
This patch fixes a bug where the irq error cleanup path did not free all the resources it allocated.
Signed-off-by: Matt Carlson Signed-off-by: Ben Li Signed-off-by: Akinobu Mita Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit ba1142e4fb291c7bf124d93596351dca8d226a0f Author: Matt Carlson Date: Fri Nov 4 09:15:00 2011 +0000
tg3: Fix 4k skb error recovery path
On the error recovery resource unwind path, it is possible for the driver to attempt to unmap a fragment that hadn't been mapped. This patch fixes the problem by correcting the "last" parameter supplied.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit b9e454826f22e17d1945bd282834c87aef8d0f95 Author: Matt Carlson Date: Fri Nov 4 09:14:59 2011 +0000
tg3: Fix 4k tx bd segmentation code
The new 4k tx bd segmentation code had a bug in the error cleanup path. If the driver did not map all the physical fragments, the abort path would wind up advancing the producer index beyond the point where the setup code stopped. This would ultimately turn into a tx recovery error where the driver would expect the skb pointer to be set when it isn't. This patch fixes the problem, and then makes the code a little easier to understand.
Signed-off-by: Matt Carlson Reviewed-by: Michael Chan Signed-off-by: David S. Miller
commit 78f94dc7b10d98cf4cf8498d98581500d910c6b7 Author: Matt Carlson Date: Fri Nov 4 09:14:58 2011 +0000
tg3: Fix APE mutex init and use
APE mutex register blocks are shared by all ports of multiport devices. For some mutexing purposes, each function is assigned their own register. For other cases, each function is assigned its own request and grant bits of a single register. For the latter cases, the tg3 driver is incorrectly allowing each function to use the same set of grant / request bits. This patch fixes the code so that each function uses the appropriate bitset.
Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller
commit 48855432047c9de7ea9987349de4c47d48ade8d1 Author: Eric Dumazet Date: Mon Oct 24 07:53:03 2011 +0000
|PATCH net-next] tg3: add tx_dropped counter
If a frame cant be transmitted, it is silently discarded.
Add a counter to report these errors to user.
Signed-off-by: Eric Dumazet Signed-off-by: David S. Miller