============================================================================== Flash Adapter 90 Release Notes IBM Version: 4.0.3 Date: June 26, 2014 ============================================================================== Contents ======== 1. Candidate Systems 2. Bug Severity Legend 3. Latest Changes 4. Upgrading the AIX Device Driver 5. Upgrading the adapter firmware in AIX and Linux 6. Errata 7. Contact Information ====================================================================== 1. Candidate Systems ---------------------- For AIX, the following should be updated: - AIX device driver - Flash Adapter 90 firmware For Linux, the following should be updated: - Flash Adapter 90 firmware and is especially recommended for: - All environments ====================================================================== 2. Bug Severity Legend ---------------------------------- The following table describes the bug severity terminology used in the release history: S1: Highest Recommend upgrade for all users as soon as possible. S2: Medium Recommend upgrade for all users at the next scheduled maintenance window. S3: Average Recommend upgrade at the next scheduled maintenance window for users experiencing these issues. All other users may wish to upgrade at the next scheduled maintenance window. S4: Low Upgrade at the next scheduled maintenance window may be performed at the discretion of the user if the issue is having a negative impact. S5: Lowest Upgrade is not necessary. Mostly cosmetic or minor annoyance fix. ====================================================================== 3. Latest Changes ---------------------------------- New Features: NONE Changes: NONE Bug Fixes: 30991 Fix issue with Flash Adapter temperature sensor reporting ====================================================================== 4. Upgrading the AIX Device Driver ---------------------------------- To update the AIX Device Driver: 1. Unconfigure all available flashsys devices rmdev -Rl Example: # lsdev | grep flashsys flashsys0 Defined 03-00 IBM Flash Adapter 90 (PCIe2 0.9TB) flashsys1 Defined 07-00 IBM Flash Adapter 90 (PCIe2 0.9TB) flashsys2 Defined 08-00 IBM Flash Adapter 90 (PCIe2 0.9TB) flashsys3 Defined 06-00 IBM Flash Adapter 90 (PCIe2 0.9TB) flashsys4 Available 05-00 IBM Flash Adapter 90 (PCIe2 0.9TB) # rmdev -Rl flashsys4 hdisk5 Defined flashsys4 Defined 2. Upgrade the AIX device driver RPM rpm -Uv Example: # rpm -Uvh rsxx-driver-1.0.1.314-1.aix6.1-7.1.ppc.rpm 0 entries added. 11 entries deleted. 0 entries updated. 0518-307 odmdelete: 1 objects deleted. rsxx-driver 0518-307 odmdelete: 8 objects deleted. =============================================================================== 5. Upgrading the adapter firmware in AIX and Linux ---------------------------------- AIX: 1. Verify that firmware file is located in '/etc/microcode' 2. Run the "diag" command. Press "Enter" 3. Select "Task Selection" 4. Select "Microcode Tasks" 5. Select "Download Microcode" 6. Select the "IBM Flash Adapter Disk" 7. A '+' should appear next to the disk 8. Press F7 9. Read the warnings and press Enter, twice 10. Select "/etc/microcode" as the download location 11. Select the newest firmware: "M XX_XXXXX" 12. The text "Please Stand By" is now displayed. 13. Wait until firmware microcode update is complete (could take up to 10 minutes). 14. After it is complete: If successful, continue to Step 15 If failure, DO NOT remove power from the card, contact support. Stop here 15. Activate the firmware If card IS NOT located in a PCIe Expansion Drawer: Shutdown entire POWER system. Leave off for 15 seconds. If card IS located in a PCIe Expansion Drawer: Perform a PCI hotplug replace procedure (without actually replacing the adapter) 16. Power the system back on or bring the card back via PCI hotplug replace if in PCIe Expansion Drawer Linux: 1. Verify the firmware file is located in '/tmp' 2. Run "rs_patch ", with root privilidges. Example: # rs_patch rsxx.07_08818 Operating on device: /dev/rsxx0 3 images available for patching Are you sure you want to continue? Enter 'Yes' to confirm: 3. Enter "Yes" and press "Enter" to confirm the applying the patch. The following should be displayed after it completes: Operating on device: /dev/rsxx0 3 images available for patching Are you sure you want to continue? Enter 'Yes' to confirm: Yes Analyzing 100.0% * Beginning firmware update. * * DO NOT INTERRUPT * Patching 100.0% Verifying 100.0% * Patch completed successfully. * * A power cycle is required. * 4. After it is complete: If successful, continue to Step 5 If failure, DO NOT remove power from the card, contact support. Stop here 5. Activate the firmware: If card IS NOT located in a PCIe Expansion Drawer: Shutdown entire POWER system. Leave off for 15 seconds. If card IS located in a PCIe Expansion Drawer: Perform a PCI hotplug replace procedure (without actually replacing the adapter) 6. Power the system back on or bring the card back via PCI hotplug replace if in PCIe Expansion Drawer =============================================================================== 6. Errata ---------------------------------- None ====================================================================== 7. Contact Information ---------------------------------- 1-800-IBM-SERV