FIRMWARE CHANGE HISTORY ----------------------- IBM RackSwitch G8316 Version 7.9.24.0 (Released March 2019) ** Changes since the 7.9.23.0 release ** Enhancements: none Changes: none Fixes: - Fixed vulnerabilities in the OpenSSL library as reported in the CVE Advisory CVE-2018-0732. (147029) ================================================================================ IBM RackSwitch G8316 Version 7.9.23.0 (Released October 2018) ** changes since release 7.9.22.0 ** Enhancements: none Changes: none Fixes: - A crash could occur when the switch were scanned by the Rapid 7 security tool or nessus scan for vulnerabilities or when the CLI commands "no ssh enable" or "no access netconf ssh enable" were executed after the scan. (133904/138760) - Fixed vulnerabilities in the TLS protocol as reported in the CVE Advisories CVE-2014-8730. (80866) - Switch no longer supports the Diffie-Hellman key exchange algorithm in strict security mode. (143643) - Enhance BBI session default user password reset framework. (135949/135951) ================================================================================ IBM RackSwitch G8316 Version 7.9.22.0 (Released June 2018) ** changes since release 7.9.21.0 ** Enhancements: none Changes: none Fixes: - Fixed Libxml2 vulnerabilities as reported in the Advisories CVE-2016-5131, CVE-2017-15412, CVE-2017-16932, CVE-2017-5130. (124059) ================================================================================ IBM RackSwitch G8316 Version 7.9.21.0 (Released November 2017) ** changes since release 7.9.20.0 ** Enhancements: none Changes: none Fixes: - Switch would crash when adding/deleting port member(s) to Openflow instance, if there were NEC vendor specific flow with drop (PFP_DROP) action in the Openflow table. (96981) - Fixed libXML2 vulnerabilities as reported in the CVE Advisories CVE-2017-8872, CVE-2017-9049 and CVE-2017-9050. (104768) - Address issue in login credential mechanism. (107614) - Support for the weak ciphers TLS_RSA_WITH_AES_128_CBC_SHA, TLS_RSA_WITH_AES_128_CBC_SHA256, TLS_DHE_RSA_WITH_AES_128_CBC_SHA, TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA has been removed. (109956/111620) - Fixed TCP vulnerabilities as reported in the CVE Advisory CVE-2017-6214. (113078) - Address non-configured community strings. (115054) - The switch’s browser based interface (BBI) was susceptible to security vulnerabilities cross-site scripting (XSS) and stored cross-site scripting as reported by the IBM security tool Appscan. (116507) - Switch would crash when the command “show mp thread” is executed, before any syslogs were logged by the switch or if logging were completely disabled on the switch. (117304) ================================================================================ IBM RackSwitch G8316 Version 7.9.20.0 (Released May 2017) ** changes since release 7.9.19.0 ** Enhancements: none Changes: - The support for TLS versions 1.1 and 1.0 has been deprecated. TLS version 1.2 is now supported by default. (PSIRT ALIRT 10820) (72679) Fixes: - The MTU value for a port in the output of “show lldp info” command is incorrectly reported as 1522 instead of 9216. (73928) - Switch fails to add all output ports received in a FlowMod message with modify-strict option when the message has more than 31 output ports. (80146) - The switch’s browser based interface (BBI) was reported to be missing the "Content-Security-Policy", "X-Content-Type-Option" and "X-XSS-Protection" headers in the HTTP response when scanned by the web security tool IBM Appscan. (68381, 75827) - In a multicast environment, switch acting simultaneously as a "Last Hop Router" (LHR) and an "Intermediate Router" (IR) would cause the switch to be unable to send traffic to LHR clients for a specific group. This happens when the switch has already received IR PIM joins for the same group, started forwarding traffic towards the IR clients and then receives LHR IGMP joins for that group. (78192) - A crash would occur when scanned by the web security tool IBM Appscan, while running a Recorded Login option. (90107) - HTTP requests sent by LXCA with a “/” URL would erroneously be rejected causing the switch’s GUI to fail to launch in LXCA (92267) - Fixed zlib vulnerabilities as reported in the CVE Advisories CVE-2016-9840, CVE-2016-9841, CVE-2016-9842 and CVE-2016-9843. (86800) - Fixed libXML2 vulnerabilities as reported in the CVE Advisories CVE-2016-4658 and CVE-2016-9318. (86808) - A switch upon receiving a rogue OSPF LSA containing its own router ID with a maximum sequence number (0x7fffffff), would incorrectly respond with a fight-back LSA of its own database, as opposed to the rogue's LSA database. (92346) ================================================================================ IBM RackSwitch G8316 Version 7.9.19.0 (Released January 2017) ** changes since release 7.9.18.0 ** Enhancements: none Changes: none Fixes: - The switch’s browser based interface (BBI) was reported to be susceptible to the security vulnerability CSRF (cross-site request forgery) when scanned by the web security tool IBM Appscan. (68381) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2016-2183(SWEET32) and CVE-2016-6329. The ciphers DES,3DES and Blowfish are no longer supported. (66395) ================================================================================ IBM RackSwitch G8316 Version 7.9.18.0 (Released September 2016) ** changes since release 7.9.17.0 ** Enhancements: none Changes: none Fixes: - Switch could crash when processing SSL traffic received on the management interface. (50705) - Password for tacacs users could not be changed from the switch using the "primary-password" command when the "tacacs-server password-change" feature is enabled. (63530) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2016-2108.(ALIRT LEN-7502). (55174) - Fixed security vulnerabilities as reported in CVE Advisories CVE-2016-3705, CVE-2016-3627, CVE-2015-8806, CVE-2016-4447, CVE-2016-4449, CVE-2016-4448 (libxml2). (57176, 55781, 58942, 58943) ================================================================================ IBM RackSwitch G8316 Version 7.9.17.0 (Released June 2016) ** changes since release 7.9.16.0 ** Enhancements: none Changes: none Fixes: - Fixed security vulnerabilities as reported in CVE Advisories CVE-2015-8710 (libxml2). (49214) - The switch’s browser based interface (BBI) was susceptible to security vulnerabilities XSS (stored cross-site scripting) and CSRF (cross-site request forgery). The web security policy mechanism HSTS (HTTP Strict Transport Security) has been implemented on BBI. (49409, 49427, 49471) - The switch’s browser based interface (BBI) would fail to honor the “cache-control=no-cache” directive and still cache the pages. The value of the “cache-control” directive has been changed from “no-cache” to “no-store”. (49475) - Switch could crash when enabling HTTPS protocol, while the switch were trying to connect to the VSI Manager. (50435) ================================================================================ IBM RackSwitch G8316 Version 7.9.16.0 (Released February 2016) ** changes since release 7.9.15.0 ** Enhancements: - Added support for QSAX (QSFP to SFP+) 1G Transceiver. (38608/ XB300748) Changes: - The output of “show tech-support” now includes the isCLI commands as headers before their respective output. (38125) Fixes: - Using Cisco ACS, version 5.3 and above, to authenticate users with TACACS protocol, could lead to the User Interface thread (SSHD,AGR,TNET,CONS) to be suspended forever, thereby denying any further authentication with the TACACS protocol. (LV307694/7383) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-7575 (SLOTH). (47856) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-3194, CVE-2015-3195. (46801) ================================================================================ IBM RackSwitch G8316 Version 7.9.15.0 (Released October 2015) ** changes since release 7.9.14.0 ** Enhancements: none Changes: - The command "show flash-dump-uuencode" in the isCLI menu and its equivalent "/maint/uudmp" from the IBMNOS-CLI menu have been deprecated. The reference to use these commands has been removed from the help tip that is posted upon user login if a flash-dump exists on the switch. (XB282980) - Added the ability for users to enable/disable SNMP login/logout traps through the "[no] snmp-server loginout-trap" command. (38040) Fixes: - The switch would fail to send ICMP TTL Exceeded messages back to the source when the incoming ICMP packet had a TTL of 1 with a destination address of the VRRP IP of the switch. As a side effect, Traceroute between devices would fail if the VRRP IP of the switch were one of the hops in the path. (LV311922) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-1788 (BN_GF2m_mod_inv), CVE-2015-1789 (X509_cmp_time) and CVE-2015-1792 (do_free_upto). (39415) ================================================================================ IBM RackSwitch G8316 Version 7.9.14.0 (Released July 2015) ** changes since release 7.9.13.0 ** Enhancements: none Changes: - Addiitonal Debugs have been added to the get more information about system queues and threads under maitenace mode.The output of the "show mp thread" now includes information about the last command processed by each STEM thread. (LV311825) Fixes: - Vlag failover due to primary switch being reloaded may incorrectly cause the secondary switch to error disable its vlag ports. This may happen when the healthcheck interface port number is higher than that of the ISL interface port number. (LV308603) - A high CPU utilization could occur during Topology Changes when running MSTP protocol in a multi tier VLAG setup. (LV310542) - Switch could hang after deleting an IP interface that is associated with OSPF. (LV311901) - An SNMP MIB walk on both the peers of a VLAG domain could result in the flap of VRRP Protocol. (XB251897/XB253845) - Fixed GLIBC vulnerabilities as reported in CVE Advisories CVE-2013-7424 (getaddrinfo()) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-0286 (ASN1_TYPE_cmp). ================================================================================ IBM RackSwitch G8316 Version 7.9.13.0 (Released April 2015) ** changes since release 7.9.11.0 ** Enhancements: none Fixes: - FCoE sessions could flap due to the High CPU Utilization caused by the software flooding of Clear Virtual Links packets with an unknown destination MAC in the FCoE VLAN. (LV296464) - All packets received with a certain MAC address are flooded subsequent to receiving an IGMP Join/Leave on the stack member with the same MAC address as source MAC. (XB271036) - A crash would occur when uploading a configuration to the switch, where the configuration file was edited to remove the leading Tab from the commands under "vlan dot1q" menu. (LV299681) - Syslog messages would be lost after a reboot, when setting the facility using “logging host <1/2> facility “ to an odd number (LV299860) - Switch could fail to install an ARP Entry for the static route or gateway leading to ARP packets getting flooded in the network. (LV301211) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2014-3572, CVE-2015-0204, CVE-2014-8275,CVE-2014-3570, CVE-2015-2808 (BarMitzvah), CVE-2014-3505, CVE-2014-3506 (openssl), CVE-2014-3507(same as 3506, d1_both.c in the DTLS implementation in OpenSSL 0.9.8 before 0.9.8zb), CVE-2014-3508 (openssl), CVE-2014-3509 (race condition in t1_lib.c) ,CVE-2014-3510 (openssl), CVE-2014-3511 (openssl). (LV304231, LV308279,XB293143) - Fixed security vulnerabilities as reported in CVE Advisories CVE-2014-0191 (libxml2) ,CVE-2013-2877(libxml2) ,CVE-2014-3660 (libxml2) , CVE-2013-2566(RC4 algo, TLS protocol),CVE-2015-0235 (GHOST/glibc) Changes: - In a vlag setup with VRRP, ICMP replies will use the Physical switch's MAC as source MAC, as opposed to the VRRP MAC. (XB292827) - Extend the ability of the command "[no] snmp-server link-trap port enable" to enable/disable link-traps for multiple interfaces. (LV302420) ================================================================================ IBM RackSwitch G8316 Version 7.9.11.0 (Released October 2014) ** changes since release 7.9.10.0 ** Enhancements: None Changes: - A security vulnerability existed in the OpenSSL Protocol that is used in IBM System Networking Ethernet Switches. (CVE-2014-3505,CVE-2014-3506,CVE-2014-3507,CVE-2014-3508,CVE-2014-3510) Fixes: None ================================================================================ IBM RackSwitch G8316 Version 7.9.10.0 (Released July 2014) ** changes since release 7.9.1.0 ** Enhancements: None Changes: - Internal debug usernames have been removed from the firmware to prevent potential backdoor access. (XB282666) Fixes: None ================================================================================ IBM RackSwitch G8316 Version 7.9.1.0 (Released June 2014) --------------------------------------------------------- VLAG-PIM with multicast sources ------------------------------- PIM is a multicast routing protocol to route the multicast traffic from multicast source to the receiver. vLAG PIM defines how PIM protocol should work over the vLAG topology. This new enhancement enables support for vLAG PIM with multicast source connected in the L2 domain behind the vLAG ports. It defines the vLAG PIM protocol behavior and traffic routing across different multicast source and receivers. With this new enhancement, multicast source and receiver can be connected anywhere in the vLAG PIM environment.This also enables vLAG PIM support in a multi tier tenant environment with L2 VLAG on the bottom tier and L3 VLAG on the top tier. Dynamic PBR ------------ Dynamic PBR feature is for routed multi-tenant environments. It allows the switch to isolate traffic in a way that keeps tenants from communicating with each other while routing all northbound traffic normally.When a tenant tries to send traffic to a neighboring tenant, the switch will redirect the traffic to an upstream router so that an upstream firewall can decide if that traffic is allowed. This feature scales better than VRF but it will only work for environments that have non-overlapping IP spaces, where each tenant has a unique IP space. LACP Individual Mode -------------------- When this feature is enabled on an LACP port-channel, if a member port of the port-channel does not receive any LACPDU over a period of time, it will be treated as a normal port which may forward data traffic according to its STP state. Service Location Protocol ------------------------- Service location Protocol provides a dynamic configuration mechanism for applications in local area networks.Applications are modeled as clients that need to find servers attached to any of the available networks within an enterprise. Auto VLAN Tagging on Trunk ports --------------------------------- This enhancement facilitates the process of adding trunk ports in VLANs by automatically adding them to all VLANs from their allowed ranges. By default, all VLANs are allowed on each port.When a port is configured as trunk port, it is automatically added to all VLANs from its allowed range. Also, when a new VLAN is created, all trunk ports which have that VLAN in their allowed ranges are automatically added to it. VLAG-MSTP Enhancement --------------------- This enhancement removes STP configuration restrictions, such as changing the MSTP instance and VLAN associations, that were enforced in previous releases when vLAG and MSTP are both enabled. The vLAG interswitch link ports are no longer error-disabled when there's an MSTP region mismatch between the vLAG switches, instead a recurring warning message is generated during the duration of the configuration mismatch. STP Range enhancement --------------------- This feature is an enhancement for existing STP commands to support configuration of a range of STP groups at a time. QBG ---- Implements IEEE802.1Qbg standard allowing server-network edge virtualization, uniform view of the VMs in the network hypervisors, allow visibility of VM traffic and automatic migration of port profiles. BGP Community Lite ------------------ This feature provides support for BGP community strings to be advertised in updates to neighbors.The switch will be configured to attach a community string to the route updates it sends to peers.In this release, the IBM switch will not make any routing changes or alterations to the community string when receiving updates with a community string attached. Display BGP Routes ------------------- This feature provides an option to display BGP advertised routes that have been advertised to a specific neighbor. Layer 3 ARP Table full ----------------------- When the L3 ARP table is full, the switch will generate a new trap message in addition to the existing syslog message. OpenFlow 1.3.1 Group support ------------------------ In this release support for OpenFlow groups in accordance with OpenFlow 1.3.1 has been added.Actions associated with flow entries can direct packets to a group. OpenFlow Support for Static LAG over Edge Ports ----------------------------------------- This feature will allow user to configure openflow static LAG port as edge port on the switch.A user can configure multiple Openflow LAG ports and physical ports as edge ports as required. sFlow support in OpenFlow ports ------------------------------- This release adds sampling support for packets received on Openflow ports configured for this feature.An sFlow server should be configured to reachable via non-openflow data port or management port for this functionality to work. IPv6 Counter enhancement ------------------------ This release adds CLI and corresponding SNMP MIB objects for IPv6 counters. The feature provides support for IPv6 neighbor cache table statistics like: Current number of installed entries. Maximum number of entries supported by router. High Water of the ipv6 neighbor cache table. Clear statistics IPSec over Virtual links ------------------------ OSPFv3 over IPSec on Virtual Links is needed to complete NIST IPSec certification for OSPFv3 traffic. IPSec is needed to secure IPv6 traffic. The feature will use IPv6 Authentication Header (AH) to provide authentication and IPv6 Encapsulating Security Payload (ESP) to provide authentication and confidentiality to virtual link packets. RMON Support (RFC1757,RFC2819) --------------------------------- Remote network monitoring devices, often called monitors or probes, are instruments that exist for the purpose of managing a network. This release supports RMON for Ethernet statistics, Ethernet History as well as Alarm and Event groups. Secure FTP ---------- This release adds support for Secure FTP (sFTP). Password Fix-Up Mode --------------------- Password Fix-Up Mode enables admin user account recovery if administrator access is lost. This release adds the option to disable password fix-up functionality to let the administrator of the switch decide whether the Fix-Up mode should be enabled or not to cover security concerns. SNMP ACL --------- This feature is an enhancement to add access control for SNMP requests. SNMP Trap Host --------------- This feature implements the SNMP interface for getting and setting SNMP host configuration for traps. IBM-NOS CLI removal ------------------- The IBM-NOS CLI will not be supported as of this release. All switches will boot up with ISCLI. The existing NOS CLI configuration still can be recognized and correctly converted to provide smooth migration for customers who have NOS CLI configuration. ESN to SNMP ------------ This feature enables SNMP access to Electronic Serial Number of the switch. Use SSH public keys for up to 20 local switch users/admins ----------------------------------------------------------- The feature allows users to login to switch via SSH using public key authentication instead of password authentication.When SSH is enabled the switch should support both password and public key authentication. The switch shall support up to 20 SSH public key users. IBM RackSwitch G8316 Version 7.8.1.0 (Released December 2013) New and Updated Features: ------------------------- OpenFlow 1.3.1 Support: ----------------------- Added support for OpenFlow Switch Specification Version 1.3.1; including but not limited to the following key features: * L3 MPLS * Static LAG * MAC/IP masking * Flexible Table Miss and Fail Secure * 40Gb support * Static CLI for Flow Programming * OpenFlow 1.0 backward compatability Full Private VLAN: ------------------ This feature supports Private VLAN configurations as described in RFC 5517. Enhanced Number of FCoE Sessions: --------------------------------- Number of FCoE sessions increased to 2000. Decoupling active VLANs from MSTP configuration: ------------------------------------------------ This feature enables the decoupling of the VLAN(s) configuration from MSTP configuration and changes the MSTP configuration menu to a more simplified one. By doing so, specifying a mapping between VLAN(s) and MSTI will not create any VLAN(s) and the participation of the VLAN(s) in MSTP will not depend on the VLAN(s) creation. NIST SP 800-131A Compliance: ---------------------------- Added a mode of operation that forces the device to operate and secure network operations in a manner that is fully compliant to the NIST SP 800-131A security standard. Removed support for obsolete cryptographic algorithms DES and MD5, as well as protocols like SSLv3, even in the non-compliant mode. Use SHA-256 as default: ----------------------- Set SHA-256 as the default and preferred hashing algorithm for all secured network operations where applicable. This includes TLS certificates and cipher suites with HMAC SHA-256 in TLS. Security Enhancements: ---------------------- Updated default protocols used for configuration to be secure. Devices will use secure protocols by default for configuration; for example: SSH, HTTPS, and SNMPv3. Insecure protocols are disabled by default for configuration; for example: Telnet, HTTP, and SNMPv1/v2. Also added a default user whose password must be changed after initial login. Remove Switch Type from login display: -------------------------------------- Removed Switch Type from login display. ACL6 Metering: -------------- Added metering support for IPv6 ACLs similar to the IPv4 ACLs. QoS Monitoring: --------------- This feature enhances the QoS statistics by presenting the COS statistics per port and per COS queue used. OSPF 20 Areas: -------------- Added support for upto 20 OSPF Areas. Increase Local Users: --------------------- Added support for up to 20 local user accounts with different privilege levels. syslog console and buffer severity: ----------------------------------- This feature provides a mechanism to configure severity level for log messages displayed on the console as well as for the syslog messages stored locally on the switch. Fixes: - A Security vulnerability existed in the TLS protocol versions TLS1.0 and earlier, in that an attacker could potentially discover the TLS session key. Added a configurable CLI option to restrict the minimum allowable protocol version of TLS, from TLS1.0 through TLS1.2. This is so that the user can avoid this vulnerability described in CVE-2011-3389, by selecting a higher protocol version that is not vulnerable to attack (TLS1.1 and above) ======================================================================================== IBM RackSwitch G8316 Version 7.7.5.0 (Released August 2013) ** Changes since the 7.7.3.0 release ** Enhancements: None Changes: - Dynamic link aggregation (LACP) ports that are not able to converge with peer ports will now result in a link-down state. This will occur when ports configured as members of an LACP trunk are connected to non-LACP ports. This is expected behavior. When connecting different IBMNOS products using LACP ports, it is recommended to install complimentary firmware versions (e.g., 7.7.5) on each device to ensure matching LACP behavior. Fixes: - Inefficiencies in the SNMP-processing code could result in high CPU utilization, SNMP client time-outs, protocol flaps, or a switch reset by the Hardware Watchdog. (66769, 70649) - User-configured ACL Deny rules were not being respected for packets with a Layer-4 (TCP) port of 22 or 23 (i.e., SSH and Telnet, respectively). (69126 / XB202484) - A prolonged period of high CPU utilization can lead to protocol-thread starvation. In one such case, LACP PDUs were not being sent by the CPU, leading to the break down of the LACP trunk forming the ISL in a vLAG topology. The ISL trunk ports that had previously been in the STP Discarding state would then errantly go into the Forwarding state, resulting in flooding of STP BPDUs into the network, and the inevitable network loop. (70887) - A hang of the Switch's I2C bus could occur, leading to a reset of the Switch by the hardware watchdog. (71721) - The SNMP dot1qVlanCurrentEntry OID was not being populated, resulting in SNMP Walks being stuck indefinitely at that point. (71785) - Disabling LACP (from the peer device) on a member port of an LACP trunk that also has STP disabled would result in the port being errantly displayed as FORWARDING in the output of the "show spanning-tree stp" command (and via the BBI), when in fact the port would be in the BLOCKING state (as designed). (71805, 71822) - Deleting the LACP key (from the peer device) on a member port of an LACP trunk that also has STP disabled would result in the port errantly going into the FORWARDING state. (71841) - With STP in PVRST mode and with a high active-port/STG product, a memory leak could occur while processing BPDUs (this was demonstrable with 47 ports active and more than 127 STGs configured per port). Over time, the memory leak could lead to a reset of the switch by the Memory Monitor. (71844) - A crash would occur when issuing the "show ufp info vport" command without explicitly specifying a vport number. (71951) - A watchdog timeout could occur if an IGMPv3 Report packet was received with the invalid source-IP address of 0.0.0.0. (71749) - Attempting to set port speed via the CMM would fail. (XB171317) - If the CMMs had "Failover on Physical Network Link" enabled (default), and the network link of the Active CMM went down, ports INTB1 and INTB2 could get disabled when the Standby CMM became active. (XB172285) - An IP address could not simultaneously be configured as a global DHCP server address, and a broadcast-domain DHCP server address. (XB172381) - A crash would occur while handling an SNMP “Get” Request for the Object that contains UFP information pertaining the switch (OID 1.0.8802.1.1.2.1.4.1.1.12.2700.65.4). (XB194463, XB202919) - A crash could occur if an FCoE-related CLI command was issued while the external management port was being flooded with packets. (XB199890) - If in Stacking mode, the switch would no longer receive time-sync updates from NTP servers over IPv6 interfaces after a CMM failover. (XB200147) - NTPv3 authentication information was being added to outgoing NTP Client Requests, even when authentication was disabled on the Switch. The consequence was that NTP servers that do not support authentication would discard the requests (i.e,, not respond to the Client Requests). (XB204541) - A crash could occur while handling an HTTPS request if the connection to the client was suddenly terminated while handling the transaction. (XB205895) - If the switch's Hostname was used to access the switch via BBI (i.e., relying on DNS instead of inputting the raw IP address), attempting to perform an image upgrade would result in redirection to a blank page. (XB206876) =============================================================================== IBM RackSwitch G8316 Version 7.7.3.0 (Released, June 2013) Enhancements: Enhanced Password security -------------------------- This feature provides stronger login enforcements for userIDs and password by forcing the local user passwords to be case sensitive, 8-64 character mix of uppercase letters, lowercase letters, numbers, and special characters, including at least one of each. Configurable port for SFTP -------------------------- This enhancement provides an option to perform SFTP operations on the switch using port numbers that can be configured explicitly (different from standard port 22) Microburst Detection -------------------- Microburst or congestion detection and control per port basis from ingress point of view based on shared memory usage and statistics logs per port per queue basis from egress point of view. DHCP Option 7 and option 12 --------------------------- These features enhance the DHCP client support on the switch to support Option 12 which defines the configuration of hostname and Option 7 which is used to get the syslog server address from DHCP server. Duplicate IP Detection ---------------------- The switch uses a simple mechanism to detect if two hosts on the same subnetwork are using the same IPv4 address at the same time. The switch sends a gratuitous ARP request for its own IP address. If it receives an ARP response, it sends a syslog message with the IP address and MAC address of the host that is using its IP address. OpenFlow 1.0 ------------ OpenFlow support has been added in this release. Hotlinks + STP -------------- In prior releases, STP needs to be disabled globally when Hotlinks feature is configured. This feature removed this limitation of having to globally disable STP. BGP multipath relax ------------------- This functionality allows load balancing across different autonomous system paths that have equal AS path length. vLAG+PIM Dense Mode ------------------- Enable the PIM protocol over the vLAG topology in dense mode for efficient multicast forwarding. Fixes: - A Security vulnerability existed in the OSPFv2 Routing Protocol that is used in IBM System Networking Ethernet Switches (CVE-2013-0149). - A Security vulnerability existed in IBM Switches which support Fibre Channel over Ethernet (FCoE), in that data frames were being flooded out of every port if the destination address was not in the MAC table. (CVE-2013-0570). ====================================================================== RackSwitch G8316 Firmware Release Version 7.6.7.0 (Released October 2013) ** Changes since the 7.6.6.0 release ** Enhancements: None. Changes: None. Fixes: - Inefficiencies in the SNMP-processing code could result in high CPU utilization, SNMP client time-outs, protocol flaps, or a switch reset by the Hardware Watchdog. (66769, 70649) - A crash would occur when routing packets to an unreachable IPv6 gateway. (68081) - A watchdog timeout could occur if an IGMPv3 Report packet was received with the invalid source-IP address of 0.0.0.0. (71749) - BGP neighborship sessions would flap when receiving BGP route messages that contained community attributes (XB194426) - A crash could occur while handling an HTTPS request if the connection to the client was suddenly terminated while handling the transaction. (XB205895) - The ACL logging feature would not report incoming packets that matched an ACL qualified by a TCP or UDP destination port. (XB208108) - A crash would occur if a data port was used to upload a file to an FTP server, if the file already existed on the server and had read-only access permissions. (XB209257) - A crash would occur if the traceroute command was executed with an IPv6 address specified, and no IPv6 management interfaces were configured. (XB215717) - A crash would occur if a ping was issued to a random host name, and an IPv6 DNS server was unreachable or non-existent (XB216882) - A crash would occur during a second attempt to authenticate a user via an unreachable or non-existent LDAP server. (XB217674) - A crash would occur if a TFTP upload or download was attempted, and no IPv6 interfaces were configured. (XB218041) - The switch's Browser-based Interface (BBI) was vulnerable to attacks by Web scanning tools, potentially resulting in crashes. (XB218795) - A crash would occur when receiving a random sequence of IGMPv3 reports that were interleaved from different Multicast receivers. (XB219263) - Invalid TCP packets (e.g., having both SYN and FIN flags set) received by the switch would not be discarded, resulting in a potential security vulnerability. (XB220985) ====================================================================== RackSwitch G8316 Firmware Release Version 7.6.6.0 (Released July 2013) ** Changes since the 7.6.5.0 release ** Enhancements: None. Changes: None. Fixes: - A Security vulnerability existed in the OSPFv2 Routing Protocol that is used in IBM System Networking Ethernet Switches (CVE-2013-0149) - A Security vulnerability existed in IBM Switches which support Fibre Channel over Ethernet (FCoE), in that data frames were being flooded out of every port if the destination address was not in the MAC table. (CVE-2013-0570) ======================================================================= RackSwitch G8316 Firmware Release Version 7.6.5.0 (Released April 2013) ** Changes since the 7.6.3.0 release ** Enhancements: None. Changes: - Added the ability in Hotlinks configurations to enable STP on non-Hotlinks ports, thus removing the previous restriction that STP be globally disabled whenever the Hotlinks feature was enabled. (67161) Fixes: - With Putty SSH client version v0.61 or later, if the amount of data being transferred is larger than the Putty Channel Window (16KB), the client will send an SSH channel request to the server. The issue was that the switch would misinterpret this request and erroneously close the session, and display the "ERROR in processing the SSH message(payload too large)" message at the terminal. (65974) - Polling the Forwarding Database via SNMP would result in prolonged high CPU utilization if the same MAC addresses were learned in multiple VLANs. This would make it difficult for the CPU to process BPDUs in a timely manner, possibly resulting in an STP topology change. (66621) - A crash would occur when booting if the "logging synchronous" command was in the startup configuration. (66885) - FTP sessions establisehed over an IPv6 interface could close unexpectedly during data transfer. (67076) - A crash would occur during reboot if the "no tacacs-server enable-bypass" command was present the start-up configuration, but the "tacacas-server enable" command was not. (67376) - A crash could occur when polling the Forwarding Database via SNMP. (67410) - With Hotlinks configured, the STP configuration would be lost when the mode was changed from RSTP to MSTP. (67522) - After disabling the Virtual Router group, the "show running" command would erroneously display the factory default information for the group. (67667) - If the LACP member port for which the PBR next-hop ARP entry was associated went down, traffic destined for the next-hop router would temporarily be lost. (68150) - After a VRRP fail-over (i.e., the Master switch goes down), the route to the PBR next-hop Router would not always be reestablished after the Backup switch became the Master, and traffic would not resume. (68352) - In a Hotlinks topology, copying either the active or backup configuration to the running configuration could lead to the HotLinks standby interface being put into the forwarding state, resulting in a network loop. (68596) - When uploading a configuration file via a Microsoft Windows SCP client, and/or if the file had been previously saved in the Windows file format, the error message "Warning : Switch type not specified. Configuration may not load properly" would be displayed. This was actually a benign error, since the upload would actually complete successfully. (69045) - Removing a VLAN from a Spanning Tree Group (STG) other than the Default STG (STG 1) would inadvertently trigger a topology change in the Default STG. (69303) - After a failover in a Hotlinks topology with more than 500 VLANs, some MAC entries would not be re-programmed in the new Master switch's Forwarding Database (FDB), resulting in flooding within the associated VLANs. (69413) - With STP disabled, MAC entries associated with a physical port would not be removed from the Forwarding Database (FDB) after adding the port to portchannel. (69571) - After changing the LACP key using the "lacp key xxx" command, the peer switch would generate a syslog recording the change, but the trunk number referenced in the syslog message would be invalid. (69590) - After a failover in a Hotlinks topology the with uplinks configured as portchannels, some MAC entries would not removed from the new Backup switch's Forwarding Database (FDB), resulting in flooding within the associated VLANs. (69917) - A crash would occur when sequentially executing the "interface [port | portchannel] shut" and "interface [port | portchannel] no shut" commands, after sFlow packets had previously been received. (70199) =============================================================================== Version 7.6.3.0 (Released February 2013) ** Changes since the 7.6.1.0 release ** Enhancements: None. Changes: - Added support for power supplies that meet the new China Compulsory Certificate (CCC) requirements for altitude and humidity. (68356) Fixes: None =============================================================================== Version 7.6.1.0 (Released December 2012) New and Updated Features ======================== BGP Route-reflector support: -------------------- Route Reflection is a technique to avoid a large number of sessions between IBGP peers. In this release, support for RFC4456 (BGP Route Reflection - An Alternative to Full Mesh Internal BGP (IBGP)) has been added. SNMP: Support for 8 Read-Only and Read-Write communities: --------------------------------------------------------- This release adds support for 8 read-community names(Read-Only), and 8 write-community names(Read-Write) with SNMPv1 and SNMPv2. RFC5340: OSPF For IPv6: ----------------------- The switch was previously compliant with RFC2740. Starting with this release, the switch is compliant with RFC5340, which supersedes RFC2740. VLAG and PIM Support: --------------------- Previous releases supported IP Multicast routing through the PIM protocol. Also previously supported was the VLAG (Virtual Link Aggregation) protocol. This release adds support for PIM over a vLAG topology, so that the most efficient multicast routing can be achieved in a vLAG topology. NTP Client Display Improvements: --------------------------------- The Network Time Protocol (NTP) is widely used to synchronize computer clocks in the Internet. With the NTP service enabled, the switch can accurately update its internal clock to be consistent with other devices on the network. In this release, the "show ntp" command has been updated with such details as clock offset, stratum, and reference clock. Also in this release is a dampening of the number of syslog messages generated when the system clock is updated or if NTP synchronization fails. Cisco like CLI: --------------- As part of this change, some existing ISCLI commands have been modified to look more like those in Cisco's IOS. The commands chosen for modification in this release are ones frequently used for VLAN, Port, and STP configuration. With these changes, those familiar with Cisco-IOS CLI can more readily configure the IBM-NOS VLAN, Port, and STP modules. Support for 4K VLANS: ----------------- Increased the scalability of VLANS from 2K to 4K