Power7 High-End Power Subsystem Firmware

Applies to:  9119-FHB

This document provides information about the installation of Licensed Machine or Licensed Internal Code, which is sometimes referred to generically as microcode or firmware.


Contents


1.0 Systems Affected

This package provides firmware for Power 795 (9119-FHB)  Servers only.  Do not use on any other systems.
 

The firmware level in this package is:


2.0 Important Information

HMC-Managed Systems

This firmware level requires  HMC V7  R7.8.0.

Go to the following URL to access the HMC code packages:

NOTE:   You must be logged in as hscroot in order for the firmware installation to complete correctly.


3.0 Firmware Information and Description

Use the following example as a reference to determine whether your installation will be concurrent or disruptive.

Note:  The file names and service pack levels used in the following examples are for clarification only, and are not
             necessarily levels that have been, or will be released.

Power Subsystem firmware file naming convention:

     02ABXXX_YYY_ZZZ

NOTE:  Values of service pack and last disruptive service pack  level (YYY and ZZZ) are only unique
within a release level (XXX).  For example, 02AB720_067_045 and 02AB730_067_053 are different
service packs.

An installation is disruptive if:

              Example:  Currently installed release is AB720, new release is AB730                Example:  AB720_061_061 is disruptive, no matter what level of AB720  is currently
                                   installed on the system                  Example:  Currently installed service pack is AB720_120_120 and
                                     new service pack is AB720_152_130

An installation is concurrent if:

              Example: Currently installed service pack  is AB720_061_061,
                                 new service pack is AB720_070_061.
 

Firmware Information and Update Description

 
Filename Size Checksum
02AB780_080_040.rpm 20,582,983 33245
 
AB780_080_040 / FW780.50

06/29/2016
 

Impact:  Availability        Severity:  SPE

Changes:
    Refresh BPC code to coincide with System Firmware update. Additionally, the following Power/Thermal related fix is included in this BPC release:
  • Add improved filtering to BPR firmware to prevent susceptibility to 350V bus noise that can cause erroneous overvoltage induced BPR power off.

AB780_075_040 / FW780.40

12/16/2015
 

Impact:  Availability        Severity:  SPE

Changes:
    Refresh BPC code to coincide with System Firmware update.

AB780_068_040 / FW780.21

01/07/2015
 

Impact:  Security        Severity:  HIPER

Changes:
    System firmware changes that affect all systems:
  • A security problem was fixed in OpenSSL for padding-oracle attacks known as Padding Oracle On Downgraded Legacy Encryption (POODLE). This attack allows a man-in-the-middle attacker to obtain a plain text version of the encrypted session data. The Common Vulnerabilities and Exposures issue number is CVE-2014-3566. The service processor POODLE fix is based on a selective disablement of SSLv3 using the Advanced System Management Interface (ASMI) "System Configuration/Security Configuration" menu options. The Security Configuration options of "nist_sp800_131a", "nist_compat", and "legacy" for affects the disablement SSLv3 and determines the level of protection from POODLE. The management console also requires a POODLE fix for APAR MB03867(FIX FOR CVE-2014-3566 FOR HMC V7 R7.9.0 SP1 with PTF MH01484) to eliminate all vulnerability to POODLE and allow use of option 1 "nist_sp800_131a" as shown below--
    • 1)nist_sp800_131a (SSlv3 disabled)- This highest level of security protection does not allow service processor clients to connect using SSLv3, thereby eliminating any possibility of a POODLE attack. All clients must be capable of using TLS v1.2 to make the secured connections to the service processor to use this option. This requires the management console be at a minimum level that has a poodle fix such as HMC V7 R7.9.0 SP1 with POODLE PTF MH01484 or HMC V7 R7.8.0 SP2 with POODLE PTF MH01432 when it becomes available.
    • 2)nist_compat (default mode - SSLv3 enabled for HMC)- This medium level of security protection disables SSLv3 (TLS v1.2 must be used instead) for the web browser sessions to ASMI and for the CIM clients and assures them of POODLE-free connections. But the older management consoles are allowed to use SSLv3 to connect to the service processor. This is intended to allow non-POODLE compliant HMC levels to be able to connect to the CEC servers until they can be planned and upgraded to the POODLE compliant HMC levels. Running a non-POODLE compliant HMC to a service processor in this default mode will prevent the ASMI-proxy sessions from the HMC from connecting as these proxy sessions require SSLv3 support in ASMI.
    • 3) legacy (SSLv3 enabled)- This basic level of security protection enables SSLv3 for all service processor client connection. It relies on all clients being at POODLE fix compliant levels to provide full POODLE protection using the TLS Fallback Signaling Cipher Suite Value (TLS_FALLBACK_SCSV) to prevent fallback to vulnerable SSLv3 connections. This legacy option is intended for customer sites on protected internal networks that have a large investment in older hardware that need SSLv3 to make browser and HMC connections to the service processor. The level of POODLE protection actually achieved in legacy mode is determined by the percentage of clients that are at the POODLE fix compliant levels.
  • A security problem was fixed in OpenSSL for memory leaks that allowed remote attackers to cause a denial of service (out of memory on the service processor). The Common Vulnerabilities and Exposures issue numbers are CVE-2014-3513 and CVE-2014-3567.

AB780_065_040 / FW780.20

10/15/2014
 

Impact:  Data        Severity:  HIPER

Changes:
  • Add filtering to BPR firmware to prevent susceptibility to 350V bus noise that can cause erroneous overvoltage induced BPR power off.

AB780_059_040 / FW780.11

6/23/2014
 

Impact:  Security        Severity:  HIPER

Changes:
    System firmware changes that affect all systems:
  • HIPER /Pervasive A security problem was fixed in the OpenSSL (Secure Socket Layer) protocol that allowed clients and servers, via a specially crafted handshake packet, to use weak keying material for communication. A man-in-the-middle attacker could use this flaw to decrypt and modify traffic between the management console and the service processor. The Common Vulnerabilities and Exposures issue number for this problem is CVE-2014-0224.
  • HIPER /Pervasive A security problem was fixed in OpenSSL for a buffer overflow in the Datagram Transport Layer Security (DTLS) when handling invalid DTLS packet fragments. This could be used to execute arbitrary code on the service processor. The Common Vulnerabilities and Exposures issue number for this problem is CVE-2014-0195.
  • HIPER /Pervasive Multiple security problems were fixed in the way that OpenSSL handled read and write buffers when the SSL_MODE_RELEASE_BUFFERS mode was enabled to prevent denial of service. These could cause the service processor to reset or unexpectedly drop connections to the management console when processing certain SSL commands. The Common Vulnerabilities and Exposures issue numbers for these problems are CVE-2010-5298 and CVE-2014-0198.
  • HIPER /Pervasive A security problem was fixed in OpenSSL to prevent a denial of service when handling certain Datagram Transport Layer Security (DTLS) ServerHello requests. A specially crafted DTLS handshake packet could cause the service processor to reset. The Common Vulnerabilities and Exposures issue number for this problem is CVE-2014-0221.
  • HIPER /Pervasive A security problem was fixed in OpenSSL to prevent a denial of service by using an exploit of a null pointer de-reference during anonymous Elliptic Curve Diffie Hellman (ECDH) key exchange. A specially crafted handshake packet could cause the service processor to reset. The Common Vulnerabilities and Exposures issue number for this problem is CVE-2014-3470.

AB780_051_040 / FW780.10

04/25/2014
 

Impact:  Servicability        Severity:  SPE

Changes:
  • System gets stuck in Low Power Mode for certain Power Line Disturbance events. Fix to take system out of this mode when disturbance recovers.
  • Post call home SRC when system is left in Low Power Mode after failed DCA repair
  • Detect and report errors on CFAM bus at DCA to reduce length and complications of repair

AB780_040_040 / FW780.00

12/06/2013
 

Impact:  New        Severity:  NEW

Changes:
  • GA Level


4.0 How to Determine Currently Installed Power Subsystem Firmware Levels

You can view the frame's current firmware level on the Advanced System Management Interface (ASMI) Welcome pane.  It appears in the top right corner.   Example:  AB720_061.

5.0 Downloading the Firmware Package

Follow the instructions on the web page. You must read and agree to the license agreement to obtain the firmware packages.

Note: If your HMC is not internet-connected you will need to download the new firmware level to a CD-ROM or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: ABXXX_YYY_ZZZ

Where XXX =  release level

Instructions for installing firmware updates and upgrades can be found at  http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7ha1/updateschapter.htm