EM350
For Impact, Severity and other Firmware definitions, Please
refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
The complete Firmware Fix History for this
Release Level can be
reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/EM-Firmware-Hist.html
|
EM350_172_038
06/23/16
|
Impact: Availability
Severity: SPE
System firmware changes that affect all
systems
- A security problem was fixed in OpenSSL for a possible
service processor reset on a null pointer de-reference during RSA PPS
signature verification. The Common Vulnerabilities and Exposures issue
number is CVE-2015-3194.
System firmware changes that
affect certain systems
- On systems with dedicated processor partitions, a
problem was fixed for the dedicated processor partition becoming
intermittently unresponsive. The problem can be circumvented by
changing the partition to use shared processors. This is a
follow-on to the fix provided in 350.G0 for a different issue for
delays in dedicated processor partitions that were caused by low I/O
utilization.
|
EM350_171_038
02/05/16
|
Impact: Security
Severity: SPE
System firmware changes that affect all
systems
- A problem was fixed for some service processor error logs
not getting reported to the OS partitions as needed. The service
processor was not checking for a successful completion code on the
error log message send, so it was not doing retries of the send to the
OS when that was needed to ensure that the OS received the message.
- For systems with an invalid P-side or T-side in the
firmware, a problem was fixed in the partition firmware Real-Time
Abstraction System (RTAS) so that system Vital Product Data (VPD) is
returned at least from the valid side instead of returning no VPD
data. This allows AIX host commands such as lsmcode, lsvpd,
and lsattr that rely on the VPD data to work to some extent even if
there is one bad code side. Without the fix, all the VPD
data is blocked from the OS until the invalid code side is recovered by
either rejecting the firmware update or attempting to update the system
firmware again.
- A security problem was fixed for an OpenSSL specially
crafted X.509 certificate that could cause the service processor to
reset in a denial-of-service (DOS) attack. The Common
Vulnerabilities and Exposures issue number is CVE-2015-1789.
- A security problem was fixed in OpenSSL where a remote
attacker could cause an infinite loop on the service processor using
malformed Elliptic Curve parameters during the SSL
authentication. This would cause the service processor
performance problems and also prevent new management console
connections from being made. To recover from this attack, a reset
or power cycle of the service processor is needed after scheduling and
completing a normal shutdown of running partitions.. The Common
Vulnerabilities and Exposures issue number is CVE-2015-1788.
- A security problem was fixed in the lighttpd server on the
service processor OpenSSL where a remote attacker, while attempting
authentication, could insert strings into the lighttpd server log
file. Under normal operations on the service processor, this does
not impact anything because the log is disabled by default. The
Common Vulnerabilities and Exposures issue number is CVE-2015-3200.
- A problem was fixed for a Network boot/install failure
using bootp in a network with switches using the Spanning Tree Protocol
(STP). A Network boot/install using lpar_netboot on the
management console was enhanced to allow the number of retries to be
increased. If the user is not using lpar_netboot, the number of
bootp retries can be increased using the SMS menus. If the SMS
menus are not an option, the STP in the switch can be set up to allow
packets to pass through while the switch is learning the network
configuration.
System firmware changes that
affect certain systems
- For non-HMC managed systems in Manufacturing Default
Configuration (MDC) mode with a single host partition, a problem was
fixed for missing dumps of type SYSDUMP. FSPDUMP. LOGDUMP, and RSCDUMP
that were not off-loaded to the host OS. This is an infrequent
error caused by a timing error that causes the dump notification signal
to the host OS to be lost. The missing/pending dumps can be
retrieved by rebooting the host OS partition. The rebooted host
OS will receive new notifications of the dumps that have to be
off-loaded.
- On PowerVM systems with dedicated processor partitions with
low I/O utilization, the dedicated processor partition may become
intermittently unresponsive. The problem can be circumvented by
changing the partition to use shared processors.
|
EM350_166_038
05/14/15
|
Impact: Availability
Severity: SPE
System firmware changes that
affect all systems
- A problem was fixed with the fspremote service tool to make
it support TLSv1.2 connections to the service processor to be
compatible with systems that had been fixed for the OpenSSL Padding
Oracle On Dowgraded Legacy Encryption (POODLE) vulnerabilities.
After the POODLE fix is installed, by default the system only
allows secured connections from clients using the TLSv1.2 protocol.
- A problem was fixed for a partition deletion error on the
management console with error code 0x4000E002 and message
"...insufficient memory for PHYP". The partition delete operation
has been adjusted to accommodate the temporary increase in memory usage
caused by memory fragmentation, allowing the delete operation to be
successful.
- A problem was fixed for I/O adapters so that BA400002
errors were changed to informational for memory boundary adjustments
made to the size of DMA map-in requests. These DMA size
adjustments were marked as UE previously for a condition that is normal.
- A security problem was fixed in OpenSSL where the service
processor would, under certain conditions, accept Diffie-Hellman client
certificates without the use of a private key, allowing a user to
falsely authenticate. The Common Vulnerabilities and Exposures
issue number is CVE-2015-0205.
- A security problem was fixed in OpenSSL to prevent a denial
of service when handling certain Datagram Transport Layer Security
(DTLS) messages. A specially crafted DTLS message could exhaust
all available memory and cause the service processor to reset.
The Common Vulnerabilities and Exposures issue number is CVE-2015-0206.
- A security problem was fixed in OpenSSL to prevent a denial
of service when handling certain Datagram Transport Layer Security
(DTLS) messages. A specially crafted DTLS message could do an
null pointer de-reference and cause the service processor to
reset. The Common Vulnerabilities and Exposures issue number is
CVE-2014-3571.
- A security problem was fixed in OpenSSL to fix multiple
flaws in the parsing of X.509 certificates. These flaws could be
used to modify an X.509 certificate to produce a certificate with a
different fingerprint without invalidating its signature, and possibly
bypass fingerprint-based blacklisting. The Common Vulnerabilities
and Exposures issue number is CVE-2014-8275.
- A security vulnerability, commonly referred to as GHOST,
was fixed in the service processor glibc functions getbyhostname() and
getbyhostname2() that allowed remote users of the functions to cause a
buffer overflow and execute arbitrary code with the permissions of the
server application. There is no way to exploit this vulnerability
on the service processor but it has been fixed to remove the
vulnerability from the firmware. The Common Vulnerabilities and
Exposures issue number is CVE-2015-0235.
- A security problem was fixed in OpenSSL where a remote
attacker could crash the service processor with malformed Elliptic
Curve private keys. The Common Vulnerabilities and Exposures
issue number is CVE-2015-0209.
- A security problem was fixed in OpenSSL where a remote
attacker could crash the service processor with a specially crafted
X.509 certificate that causes an invalid pointer, out-of-bounds write,
or a null pointer de-reference. The Common Vulnerabilities and
Exposures issue numbers are CVE-2015-0286, CVE-2015-0287, and
CVE-2015-0288.
System firmware changes that
affect certain systems
- On a system with redundant service processors, a problem
was fixed for an operations panel core dump with SRC B181A0FA during an
administrative failover (AFO) of the service processor.
- On a system with redundant service processors, a problem
was fixed for bad pointer reference in the mailbox function during data
synchronization between the two service processors. The
de-reference of the bad pointer caused a core dump, reset/reload, and
fail-over to the backup service processor.
- On systems that have Active Memory Sharing (AMS)
partitions, a problem was fixed for Dynamic Logical Partitioning
(DLPAR) for a memory remove that leaves a logical memory block (LMB) in
an unusable state until partition reboot.
- On systems with a F/C 5802 or 5877 I/O drawer installed, a
problem was fixed for a hypervisor hang at progress code C7004091
during the IPL or hangs during serviceability tasks to the I/O drawer.
- On systems with partitions using shared processors, a
problem was fixed that could result in latency or timeout issues with
I/O devices.
- A problem was fixed that could result in unpredictable
behavior if a memory UE is encountered while relocating the contents of
a logical memory block during one of these operations:
- Using concurrent maintenance to perform a hot repair of a node.
- Reducing the size of an Active Memory Sharing (AMS) pool.
- A problem was fixed for systems in networks using the
Juniper 1GBe and 10GBe switches (F/Cs #1108, #1145, and #1151) to
prevent network ping errors and boot from network (bootp)
failures. The Address Resolution Protocol (ARP) table information
on the Juniper aggregated switches is not being shared between the
switches and that causes problems for address resolution in certain
network configurations. Therefore, the CEC network stack code has
been enhanced to add three gratuitous ARPs (ARP replies sent without a
request received) before each ping and bootp request to ensure that all
the network switches have the latest network information for the system.
- On systems in IPv6 networks, a problem was fixed for
a network boot/install failing with SRC B2004158 and IP address
resolution failing using neighbor solicitation to the partition
firmware client.
- For systems with a IBM i load source disk attached to an
Emulex-based fibre channel adapter such as F/C #5735, a problem was
fixed that caused an IBM i load source boot to fail with SRC B2006110
logged and a message to the boot console of "SPLIT-MEM Out of
Room". This problem occurred for load source disks that needed
extra disk scans to be found, such as those attached to a port other
than the first port of a fibre channel adapter (first port requires
fewest disk scans).
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- A problem was fixed for concurrent maintenance operations
to limit hardware retries on failed hardware so that it can be
concurrently repaired.
- A problem was fixed for a power off failure of an expansion
drawer (F/C 5802 or F/C 5877) during a concurrent repair. The
power off commands to the drawer are now tried again using the System
Power Control Network (SPCN) serial connection to the drawer to allow
the repair to continue.
- A problem was fixed for concurrent maintenance to prevent a
hardware unavailable failure when doing consecutive concurrent remove
and add operations to an I/O Hub adapter for a drawer.
|
EM350_163_038
01/08/15
|
Impact: Security
Severity: SPE
System firmware changes that
affect all systems
- A security problem
was fixed in the OpenSSL (Secure Socket Layer) protocol that allowed a
man-in -the middle attacker, via a specially crafted fragmented
handshake packet, to force a TLS/SSL server to use TLS 1.0, even if
both the client and server supported newer protocol versions. The
Common Vulnerabilities and Exposures issue number for this problem is
CVE-2014-3511.
- A security problem was fixed in OpenSSL for formatting
fields of security certificates without null-terminating the output
strings. This could be used to disclose portions of the program
memory on the service processor. The Common Vulnerabilities and
Exposures issue number for this problem is CVE-2014-3508.
- Multiple security problems were fixed in the way that
OpenSSL handled Datagram Transport Layer Security (DLTS) packets.
A specially crafted DTLS handshake packet could cause the service
processor to reset. The Common Vulnerabilities and Exposures
issue numbers for these problems are CVE-2014-3505, CVE-2014-3506 and
CVE-2014-3507.
- A security problem was fixed in OpenSSL to prevent a denial
of service when handling certain Datagram Transport Layer Security
(DTLS) ServerHello requests. A specially crafted DTLS handshake
packet with an included Supported EC Point Format extension could cause
the service processor to reset. The Common Vulnerabilities and
Exposures issue number for this problem is CVE-2014-3509.
- A security problem was fixed in OpenSSL to prevent a denial
of service by using an exploit of a null pointer de-reference during
anonymous Diffie Hellman (DH) key exchange. A specially crafted
handshake packet could cause the service processor to reset. The
Common Vulnerabilities and Exposures issue number for this problem is
CVE-2014-3510.
- A security problem was fixed in OpenSSL for memory leaks
that allowed remote attackers to cause a denial of service (out of
memory on the service processor). The Common Vulnerabilities and
Exposures issue numbers are CVE-2014-3513 and CVE-2014-3567.
- A security problem was fixed in OpenSSL for padding-oracle
attacks known as Padding Oracle On Dowgraded Legacy Encryption
(POODLE). This attack allows a man-in-the-middle attacker to
obtain a plain text version of the encrypted session data. The Common
Vulnerabilities and Exposures issue number is CVE-2014-3566. The
service processor POODLE fix is based on a selective disablement of
SSLv3 using the Advanced System Management Interface (ASMI) "System
Configuration/Security Configuration" menu options. The Security
Configuration options of "Disabled", "Default", and "Enabled" for SSLv3
determines the level of protection from POODLE. The management
console also requires a POODLE fix for APAR MB03867(FIX FOR
CVE-2014-3566 FOR HMC V7 R7.7.0 SP4 with PTF MH01482) to eliminate all
vulnerability to POODLE and allow use of option 1 "Disabled" as shown
below:
-1) Disabled: This highest level of security protection does not
allow service processor clients to connect using SSLv3, thereby
eliminating any possibility of a POODLE attack. All clients must
be capable of using TLS to make the secured connections to the service
processor to use this option. This requires the management
console be at a minimum level of HMC V7 R7.7.0 SP4 with POODLE PTF
MH01482.
-2) Default: This medium level of security protection disables
SSLv3 for the web browser sessions to ASMI and for the CIM clients and
assures them of POODLE-free connections. But the legacy
management consoles are allowed to use SSLv3 to connect to the service
processor. This is intended to allow non-POODLE compliant HMC
levels to be able to connect to the CEC servers until they can be
planned and upgraded to the POODLE compliant HMC levels. Running
a non-POODLE compliant HMC to a service processor in "Default"
mode will prevent the ASMI-proxy sessions from the HMC from connecting
as these proxy sessions require SSLv3 support in ASMI.
-3) Enabled: This basic level of security protection enables
SSLv3 for all service processor client connection. It relies on
all clients being at POODLE fix compliant levels to provide full POODLE
protection using the TLS Fallback Signaling Cipher Suite Value
(TLS_FALLBACK_SCSV) to prevent fallback to vulnerable SSLv3
connections. This option is intended for customer sites on
protected internal networks that have a large investment in legacy
hardware that need SSLv3 to make browser and HMC connection to the
service processor. The level of POODLE protection actually
achieved in "Enabled" mode is determined by the percentage of clients
that are at the POODLE fix compliant levels.
|
EM350_159_038
06/25/14
|
Impact: Security
Severity: HIPER
New Features and Functions
- Support was dropped
for Secured Socket Layer (SSL) Version 2 and SSL weak and medium cipher
suites in the service processor web server (Ligthttpd).
Unsupported web browser connections to the Advanced System Management
Interface (ASMI) secured port 443 (using https://) will now be rejected
if those browsers do not support SSL version 3. Supported web
browsers for Power6 ASMI are Netscape (version 9.0.0.4), Microsoft
Internet Explorer (version 7.0), Mozilla Firefox (version 2.0.0.11),
and Opera (version 9.24).
System firmware changes that
affect all systems
- HIPER/Pervasive:
A
security problem was fixed in the OpenSSL Montgomery ladder
implementation for the ECDSA (Elliptic Curve Digital Signature
Algorithm) to protect sensitive information from being obtained with a
flush and reload cache side-channel attack to recover ECDSA nonces from
the service processor. The Common Vulnerabilities and Exposures
issue
number is CVE-2014-0076. The stolen ECDSA nonces could be used to
decrypt the SSL sessions and compromise the Hardware Management Console
(HMC) access password to the service processor. Therefore, the
HMC
access password for the CEC should be changed after applying this fix.
- HIPER/Pervasive:
A
security problem was fixed in the OpenSSL Transport Layer Security
(TLS) and Datagram Transport Layer Security (DTLS) to not allow
Heartbeat Extension packets to trigger a buffer over-read to steal
private keys for the encrypted sessions on the service processor.
The
Common Vulnerabilities and Exposures issue number is CVE-2014-0160 and
it is also known as the heartbleed vulnerability. The stolen
private
keys could be used to decrypt the SSL sessions and and compromise the
Hardware Management Console (HMC) access password to the service
processor. Therefore, the HMC access password for the CEC should
be
changed after applying this fix.
- HIPER/Pervasive:
A security problem was fixed in the OpenSSL (Secure Socket Layer)
protocol that allowed clients and servers, via a specially crafted
handshake packet, to use weak keying material for communication.
A man-in-the-middle attacker could use this flaw to decrypt and modify
traffic between the management console and the service processor.
The Common Vulnerabilities and Exposures issue number for this problem
is CVE-2014-0224.
- HIPER/Pervasive:
A security problem was fixed in OpenSSL for a buffer overflow in the
Datagram Transport Layer Security (DTLS) when handling invalid DTLS
packet fragments. This could be used to execute arbitrary code on
the service processor. The Common Vulnerabilities and Exposures
issue number for this problem is CVE-2014-0195.
- HIPER/Pervasive:
Multiple security problems were fixed in the way that OpenSSL handled
read and write buffers when the SSL_MODE_RELEASE_BUFFERS mode was
enabled to prevent denial of service. These could cause the
service processor to reset or unexpectedly drop connections to the
management console when processing certain SSL commands. The
Common Vulnerabilities and Exposures issue numbers for these problems
are CVE-2010-5298 and CVE-2014-0198.
- HIPER/Pervasive:
A security problem was fixed in OpenSSL to prevent a denial of service
when handling certain Datagram Transport Layer Security (DTLS)
ServerHello requests. A specially crafted DTLS handshake packet could
cause the service processor to reset. The Common Vulnerabilities
and Exposures issue number for this problem is CVE-2014-0221.
- HIPER/Pervasive:
A security problem was fixed in OpenSSL to prevent a denial of service
by using an exploit of a null pointer de-reference during anonymous
Elliptic Curve Diffie Hellman (ECDH) key exchange. A specially
crafted handshake packet could cause the service processor to
reset. The Common Vulnerabilities and Exposures issue number for
this problem is CVE-2014-3470.
- A problem was fixed that caused the system
information LED to be lit without a corresponding SRC and error log for
the event. This problem typically occurs when an operating system
on a partition terminates abnormally.
- A security problem was fixed in the service processor
Lighttpd web server that allowed denial of service vulnerabilities for
the Advanced System Manager Interface (ASMI). The Common
Vulnerabilities and Exposures issue numbers for this problem are
CVE-2011-4362 and CVE-2012-5533.
- A problem was fixed on the service processor where the
Small-Footprint CIM Broker Daemon (SFCBD) process was accessing a null
pointer and failing with a core dump, triggering a FSP dump to collect
the core.
- A problem was fixed that caused a security scan of the
Advanced System Manager Interface (ASMI) to fail. The Lighttpd
web server configuration cipher list was updated to improve the
security.
- A security problem in the Secure Socket Layer (SSL)
protocol on the service processor was fixed to prevent a
man-in-the-middle attack. The Common Vulnerabilities and
Exposures issue number is CVE-2011-3389.
- A security problem was fixed for the Lighttpd web
server that allowed arbitrary SQL commands to be run on the service
processor of the CEC. The Common Vulnerabilities and Exposures
issue number is CVE-2014-2323.
- A security problem was fixed for the Lighttpd web server
where improperly-structured URLs could be used to view arbitrary files
on the service processor of the CEC. The Common Vulnerabilities
and Exposures issue number is CVE-2014-2324..
- A problem was fixed that caused a "code accept" during a
concurrent firmware installation from the HMC to fail with SRC E302F85C.
- A security problem was fixed in the service processor
TCP/IP stack to discard illegal TCP/IP packets that have the SYN and
FIN flags set at the same time. An explicit packet discard was
needed to prevent further processing of the packet that could result in
an bypass of the iptables firewall rules.
System firmware changes that
affect certain systems
- On systems using dynamic Distributed Host Control Protocol
(DHCP) IP addresses, a problem was fixed that caused communication
hangs when DHCP client processes were unable to renew their IP
addresses. The iptable rules needed to be updated to open DHCP
ports 67 and 68 to prevent the DHCP network traffic from being filtered
by the service processor.
- On a system with partitions with redundant Virtual
Asynchronous Services Interface (VASI) streams, a problem was fixed
that caused the system to terminate with SRC B170E540. The
affected partitions include Active Memory Sharing (AMS), encapsulated
state partitions, and hibernation-capable partitions. The problem
is triggered when the management console attempts to change the active
VASI stream in a redundant configuration. This may occur due to a
stream reconfiguration caused by Live Partition Mobility (LPM);
reconfiguring from a redundant Paging Service Partition (PSP) to a
single-PSP configuration; or conversion of a partition from AMS to
dedicated memory.
- On systems involved in a series of consecutive Live
Partition Mobility (LPM) operations, a memory leak problem was fixed in
the run time abstraction service (RTAS) that caused a partition run
time AIX crash with SRC 0c20. Other possible symptoms include
error logs with SRC BA330002 (RTAS memory allocation failure).
- On a system with a
disk device with multiple boot partitions, a problem was fixed that
caused System Management Services (SMS) to list only one boot
partition. Even though only one boot partition was listed in SMS,
the
AIX bootlist command could still be used to boot from any boot
partition.
- For a partition with a 256MB Real Memory
Offset (RMO) region size that has been migrated from a Power8 system
to Power7 or Power6 using Live Partition Mobility, a problem was
fixed
that caused a failure on the next boot of the partition with a BA210000
log with a CA000091 checkpoint just prior to the BA210000. The
fix
dynamically adjusts the memory footprint of the partition to fit on the
earlier Power systems.
- On systems with a redundant service processor, a problem
was fixed that caused a SRC B150D15E to be erroneously logged after a
failover to the sibling service processor.
- On systems with a F/C 5802 or 5877 I/O drawer installed, a
problem was fixed that where an Offline Converter Assembly (OCA) fault
would appear to persist after an OCA micro-reset or OCA
replacement. The fault bit reported to the OS may not be cleared,
indicating a fault still exists in the I/O drawer after it has been
repaired.
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- A problem was fixed that caused a concurrent hot add/repair
maintenance operation to fail with SRC B181394F.
|
EM350_149_038
07/25/13
|
Impact: Availability
Severity: SPE
System firmware changes that
affect all systems
- A problem was fixed that caused the managed system to go to
the incomplete state on the management console after a partition was
deleted.
- A problem was fixed that caused an error log generated by
the partition firmware to show conflicting firmware levels. This
problem occurs after a firmware update or a logical partition migration
(LPM) operation on the system.
- The firmware was enhanced to display on the management
console the correct number of concurrent live partition mobility (LPM)
operations that is supported.
- A problem was fixed that caused the state of the Host
Ethernet Adapter (HEA) port of be reported as down when the physical
port is actually up.
- A problem was fixed that caused the partition target of a
logical partition migration (LPM) to have its UTC time shifted forward
from the actual time on the source partition.
- A problem was fixed that that caused a HMC code update
failure for the FSP on the accept operation with SRC B1811402 or FSP is
unable to boot on the updated side.
System firmware changes that
affect certain systems
- On systems with I/O towers attached, a problem was fixed
that caused multiple service processor reset/reloads if the tower was
continuously sending invalid System Power Control Network (SPCN) status
data.
- On a partition with a large number of potentially bootable
devices, a problem was fixed that caused the partition to fail to boot
with a default catch, and SRC BA210000 may also be logged.
- On systems running AIX or Linux, a problem was fixed that
caused the operating system to halt when an InfiniBand Host Channel
Adapter (HCA) adapter fails or malfunctions.
- On systems running Active Memory Sharing (AMS) partitions,
a timing problem was fixed that may occur if the system is undergoing
AMS pool size changes.
- On systems with a F/C 5802 or 5877 I/O drawer installed,
the firmware was enhanced to guarantee that an SRC will be generated
when there is a power supply voltage fault. If no SRC is
generated, a loss of power redundancy may not be detected, which can
lead to a drawer crash if the other power supply goes down. This
also fixes a problem that causes an 8 GB Fiber channel adapter in
the drawer to log errors if the 12V level fails in the drawer.
- On systems with a F/C 5802 or 5877 I/O drawer installed, a
problem was fixed that caused the hardware topology on the management
console for the managed system to show "null" instead of "operational"
for the affected I/O drawers.
- A problem was fixed that caused a migrated partition to
reboot during transfer to a VIOS 2.2.2.0, and later, target system. A
manual reboot would be required if transferred to a target system
running an earlier VIOS release. Migration recovery may also be
necessary.
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- On systems running multiple IBM i partitions that are
configured to communicate with each other via virtual Opticonnect,
concurrent hot add/repair maintenance operations may time-out.
When this problem occurs, a platform reboot may be required to recover.
|
EM350_143_038
01/09/13
|
Impact: Function
Severity: ATT
System firmware changes that
affect all systems
- A problem was fixed that caused the hypervisor to be left
in an inconsistent state after a partition create operation failed.
- A problem was fixed that caused the hypervisor to become
unresponsive and the managed system to go the incomplete state on the
management console.
- A problem was fixed that caused the service processor to
fail to boot after a concurrent firmware update; this causes a system
crash.
System firmware changes that
affect certain systems
- A problem was fixed that prevented the HMC command
"lshwres" from showing any I/O adapters if any adapter name contained
the ampersand character in the VPD.
- The Power Hypervisor was enhanced to insure better
synchronization of vSCSI and NPIV I/O interrupts to partitions.
- On systems running AIX or Linux, a problem was fixed that
caused a partition to fail to boot with SRC CA260203. This
problem also can cause concurrent firmware updates to fail.
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- A problem was fixed that caused the Hypervisor to become
unresponsive during a concurrent maintenance operation.
|
EM350_132_038
07/27/12
|
Impact: Availability
Severity: SPE
New Features and Functions
- Support for live
partition mobility between systems running Ex350
system firmware, and 8246-L2S systems.
System firmware changes that
affect all systems
- The firmware was
enhanced to improve the isolation of the failing component when SRC
110016x1 (VRM failure) is logged.
System firmware changes that
affect certain systems
- On systems booting from an NPIV (N-port ID virtualization)
device, a problem was fixed that caused the boot to intermittently
terminate with the message "PReP-BOOT: unable to load full PReP
image.". This problem occurs more frequently on the IBM V7000
Storage System running the SAN Volume Controller (SVC), but not on
every boot.
- On systems on which Internet Explorer (IE) is used to
access the Advanced System Management Interface (ASMI) on the Hardware
Management Console (HMC), a problem was fixed that caused IE to hang
for about 10 minutes after saving changes to network parameters on the
ASMI.
- On systems running the AIX operating system, a problem was
fixed that caused the hypervisor to crash with SRC B7000103, after an
HEA (Host Ethernet Adapter) error was logged, when there is a lot of
AIX activity on the HEAs.
|
EM350_126_038
05/02/12
|
Impact: Availability
Severity: HIPER - High Impact/PERvasive, Should be installed as soon as
possible.
System firmware changes that
affect all systems
- The firmware was enhanced to log SRCs BA180030 and BA180031
as informational instead of predictive.
- The firmware was enhanced to increase the threshold of soft
NVRAM errors on the service processor to 32 before SRC B15xF109 is
logged. (Replacement of the service processor is recommended if
more than one B15xF109 is logged per week.)
System firmware changes that
affect certain systems
- The firmware resolves undetected N-mode stability problems
and improves error reporting on the feature code (F/C) 5802 and 5877
I/O drawer power subsystem.
- HIPER/Pervasive:
On systems with PCI adapters in a feature code (F/C) F/C 5802 or 5877
I/O drawer assigned to a Virtual I/O Server (VIOS), and on systems with
the I/O adapters in a CEC drawer assigned to a VIOS, a problem was
fixed that caused the system to crash with SRC B700F103.
- A problem was fixed that caused the hypervisor to hang
during a concurrent operation on a F/C 5802, 5803, 5873 or 5877 I/O
drawer. Recovering from the hypervisor hang required a platform
reboot.
- On system
performing Live Partition Mobility (LPM), a problem was fixed
that caused a partition to crash if the following sequence of
operations is performed:
1. The partition is configured with, and is using, more than 1
dedicated processor.
2. The partition is migrated using LPM from a POWER6 to a POWER7
platform.
3. At any time following the migration from POWER6 to POWER7, one
or more of the dedicated processors is removed from the partition using
a Dynamic Logical Partitioning (DLPAR) operation.
Once these 3 steps operations have been done, a partition crash
is likely if either:
- The partition is subsequently migrated to any other platform
(POWER6 or POWER7) using LPM, or
- The partition is resumed from hibernation.
- A problem was fixed that caused the output of the AIX
command "uname -m" to be incorrect on the POWER7 system after a
successful Live Partition Migration (LPM) operation from a POWER6 to a
POWER7 system.
- A problem was fixed that prevented the operating system
from being notified that a F/C 5802 or 5877 I/O drawer had recovered
from an input power fault (SRC 10001512 or 10001522).
- The firmware was enhanced to improve soft error recovery
and error reporting on feature code (F/C) 5802 and 5877 I/O drawers.
- A problem was fixed that caused booting from a virtual
fibre channel tape device to fail with SRC B2008105.
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- A problem was fixed that caused the hypervisor's memory
usage to grow during a concurrent maintenance node evacuation
operation. When this problem occurred, the amount of reserved
memory (the memory the hypervisor is using) increases, and the amount
of available memory decreases, as viewed on the Hardware Management
Console (HMC) or System Director Management Console (SDMC).
|
EM350_118_038
10/27/11
|
Impact: Availability
Severity: HIPER - High Impact/PERvasive, Should be installed as soon as
possible.
System firmware changes that
affect all systems
- A problem was fixed that
caused the system to terminate when rebooting after the power was
removed, then reapplied.
- A problem was fixed that
caused the message "IPL: 500 - Internal Server Error" to be displayed
when the Hardware Management Console option was selected (which is
under the System Information option) on the Advanced System Management
Interface (ASMI).
- On systems running more than
100 logical partitions, a problem was fixed that caused a concurrent
firmware installation to fail.
- A problem was fixed that caused a system's partition
dates to revert back to 1969 after the service processor or its battery
was replaced. This occurred regardless of whether or not the
service processor's time-of-day (TOD) clock was correctly set during
the service action.
- A problem was fixed that
caused a partition migration operation to abort when the partition has
more than 4096 virtual slots.
- A problem was fixed that
caused the message "500 - Internal Server Error." to be displayed when
a setting was changed on the Advanced System Management Interface's
(ASMI's) power on/off menu, when the change was attempted when the
system was powering down.
- A problem was fixed that
caused booting or installing a partition or system from a USB device to
fail with error code BA210012. This usually occurs when an
operating system (OS) other than the OS that is already on the
partition or system is being booted or installed.
- On the System Management Services (SMS) remote IPL (RIPL)
menus, a problem was fixed that caused the SMS menu to continue to show
that an Ethernet device is configured for iSCSI, even though the user
has changed it to BOOTP.
- A problem was fixed that
caused a firmware installation from the HMC with the "do not auto
accept" option selected to fail.
System firmware changes that
affect certain systems
- On systems
running IBM i partitions, a problem was fixed that caused changing the
processor weight on an IBM i partition to 255 to have no effect.
- On system using the utility
capacity on demand (COD) feature, a problem was fixed that prevented
the hypervisor from correctly crediting the time used when the sequence
number of the activation code reached certain values.
- HIPER/Non-Pervasive:
On systems running Active Memory Sharing (AMS) with a feature code
(F/C) 5802 or 5877 I/O drawer attached, a problem was fixed that caused
the system to crash with SRC B170E540 after a warm boot or platform
dump IPL.
- On systems with an iSCSI
network, a problem was fixed that caused the system to hang when
booting from an iSCSI device in the system management services (SMS)
menus.
- On systems with an iSCSI
network, when booting a logical partition using that iSCSI network, a
problem was fixed that caused the iSCSI gateway parameter displayed on
the screen to be incorrect. It did not impact iSCSI boot
functionality.
- On systems using fibre channel
adapters, the firmware was enhanced by the addition of a new option in
the system management services (SMS) Mutliboot menu that facilitates
zoning of physical and virtual fibre channel adapters.
- On systems with
external I/O drawers, the firmware was enhanced such that SRCs 10001B02
and 1000911C place a call home.
- On systems with
external InfiniBand or PCI-E drawers or towers, a problem was fixed
that caused the system to crash with SRC B7000103 if the I/O hub
adapter crashed at the same time an external drawer or tower was being
initialized.
Concurrent hot add/repair
maintenance (CHARM) firmware fixes
- On partitions running Red Hat
Linux 6.1, a problem was fixed that caused a node evacuation operation
to fail.
- HIPER/Non-Pervasive:
On systems with a F/C 5802 or 5877 I/O drawer attached, a
problem was fixed that caused the system to crash with SRC B170E540
after a warm boot or platform dump IPL.
- A problem was fixed
that caused the host Ethernet adapters (HEA) to be in a non-functional
state after a hot node add.
|