Power7 System Firmware
Applies to: 9119-FHB
This document provides information about the installation of
Licensed
Machine or Licensed Internal Code, which is sometimes referred to
generically
as microcode or firmware.
Contents
1.0 Systems Affected
This package provides firmware for Power 795 (9119-FHB) Servers
only.
The firmware level in this package is:
1.1 Minimum HMC Code Level
This section is intended to describe the "Minimum HMC Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the HMC level must be
equal to or higher than the "Minimum HMC Code Level" before starting
the system firmware update. If the HMC managing the server
targeted for the System Firmware update is running a code level lower
than the "Minimum HMC
Code Level" the firmware update will not proceed.
The
Minimum HMC Code level for
this firmware is: HMC V7 R7.6.0
Service Pack 1 (PTF MH01329).
Although the Minimum HMC Code
level
for this firmware is listed
above, either of the following HMC Levles and eFixes are
suggested for this firmware level.
Note that the following levels contain important fixes and should be
installed prior to updating to this firmware level.
- HMC level V7 R7.6.0 Service
Pack 3 (PTF MH01350) or
higher.
or
-
HMC level V7 R7.7.0 Service Pack 3 (MH01379) or
higher.
For information concerning HMC releases and the latest
PTFs,
go
to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/
For specific fix level
information on key components of IBM
Power Systems running the AIX, IBM i and Linux operating systems, we
suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home
NOTE: You must be logged in as hscroot in order for the
firmware
installation to complete correctly.
2.0 Important Information
HMC Note:
When attempting to open ASM on a local HMC, an empty/blank window
is
opened and the logon screen does not appear. The problem affects only
ASM to POWER7 servers at the firmware levels listed below. The
problem does not affect accessing ASM from a remote HMC session
or logging in directly from a PC browser.
Versions impacted:
HMC V7R7.1.0 and later
Power 7 Servers: 780 (all levels) or later, 770_062 or later, 760_078
or later
Circumvention:
Use a remote HMC login session or connect a PC directly to the FSP.
Fix:
A fix is planned for HMC 7.7.7 and 7.7.8.
Special Instructions for
Upgrading
to Server Firmware AH760:
- POWER7 9119-FHB servers
with a maximum partition value less than 1000 partitions need to
disconnect any redundant (Dual) HMC temporarily before performing a
server firmware upgrade from 01AH730 (or earlier) to 01AH760. The
HMC can be reconnected after the upgrade is complete.
Note:
If the dual HMC is not disconnected prior to the upgrade, the upgrade
will fail shortly after the "retrieving updates" stage with the
following error:
HSCF0999 - Disconnect or power-off the sibling management console(s)
from the following list and retry the update. After the update is
complete, reconnect or power-on the sibling.
The requested update level can not be applied on the following server
from this management console (<HMC performing the upgrade>) while
the server is managed by multiple management consoles. management
console(s).
<server MTMS>: Sibling console(s)
- If the direct access to the
HMC is available, the recommended method is to power off the dual
(peer) HMC.
-
On the dual HMC, select HMC Management, then the Shut Down and Restart
task.
- On the Shutdown or Restart panel select Shutdown HMC and click
OK.
- If the HMC is in a remote or "lights out" data center then the HMC
can be disconnected from the server and frame.
See the following document for detailed
information: http://www-912.ibm.com/s_dir/slkbase.NSF/DocNumber/650380499
ECA Info:
Before upgrading your system from AH720 to
AH730/AH760 firmware release, contact your authorized provider and ask
about ECA 256 and ECA 303, as hardware may have to be upgraded.
SPPL NOTE:
In some previous firmware releases, the system firmware
was not properly enforcing the system partition processor limit (SPPL)
attribute for shared processor partitions. This service pack
fixes that enforcement to ensure that shared processor partitions
comply with the limit for virtual processors when the SPPL setting is
24 or 32.
You will be affected by this change if you have the following
configuration:
- 795 class server (model 9119-FHB)
- The server has 3 or fewer books, or the server has 4 or
more books and the SPPL attribute is set to 24 or 32.
- The server has 24 processor cores per book and you have
configured more than 24 virtual processors for a shared processor
partition.
- The server has 32 processor cores per book and you have
configured more than 32 virtual processors for a shared processor
partition.
After this service pack is installed, the behavior of the shared
processor partitions that exceed the SPPL attribute will change as
follows:
- Partition activation:
- Partitions will continue to boot and reboot successfully
unless the minimum number of virtual processors is greater than the
SPPL.
- Partitions that are activated will limit the number of
active virtual processors to no more than the SPPL limit.
- Partition configuration:
- Errors that are logged when the SPPL is exceeded can
result in HMC errors HSCLA4D6 and HSC0A4D6.
- Attempts to change the number of virtual processors or
entitled processing units via a profile or dynamic LPAR change will be
subject to the SPPL setting of 24 or 32.
For example, if the SPPL is set to 32 and
your shared processor partition is configured with 40 virtual
processors, you must reduce the number of virtual
processors to 32 or fewer for the change to be successful.
- If you create a new shared processor partition, the
number of virtual processors must not exceed the SPPL value.
- Partition mobility:
- A partition must comply with the SPPL of the
target server.
- Partition hibernation (suspend/resume):
- If you have suspended partitions that have exceeded the
SPPL limit and install this service pack, you will not be able to
successfully resume those suspended
partitions. You should ensure all suspended
partitions comply with (have virtual processors fewer than or equal to)
the new SPPL limit before installing this service pack.
Downgrading firmware from any
given release level to an earlier release level is not recommended.
If you feel that it is
necessary to downgrade the firmware on
your system to an earlier release level, please contact your next level
of support.
IPv6 Support and Limitations
IPv6 (Internet Protocol version 6) is supported in the System
Management
Services (SMS) in this level of system firmware. There are several
limitations
that should be considered.
When configuring a network interface card (NIC) for remote IPL, only
the most recently configured protocol (IPv4 or IPv6) is retained. For
example,
if the network interface card was previously configured with IPv4
information
and is now being configured with IPv6 information, the IPv4
configuration
information is discarded.
A single network interface card may only be chosen once for the boot
device list. In other words, the interface cannot be configured for the
IPv6 protocol and for the IPv4 protocol at the same time.
Memory Considerations for Firmware Upgrades
Firmware Release Level upgrades and Service Pack updates may consume
additional system memory.
Server firmware requires memory to support the logical partitions on
the server. The amount of memory required by the server firmware varies
according to several factors.
Factors influencing server firmware memory requirements include the
following:
- Number of logical partitions
- Partition environments of the logical
partitions
- Number of physical and virtual I/O devices
used by the logical partitions
- Maximum memory values given to the logical
partitions
Generally, you can estimate the amount of memory required by server
firmware to be approximately 8% of the system installed memory. The
actual amount required will generally be less than 8%. However, there
are some server models that require an absolute minimum amount of
memory for server firmware, regardless of the previously mentioned
considerations.
Additional information can be found at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hat/iphatlparmemory.htm
3.0 Firmware
Information
and Description
Use the following examples as a reference to determine whether your
installation
will be concurrent or disruptive.
Note: The concurrent levels
of system firmware may, on occasion,
contain
fixes that are known as Deferred and/or Partition-Deferred. Deferred
fixes can be installed
concurrently, but will not be activated until the next IPL.
Partition-Deferred fixes can be installed concurrently, but will not be
activated until a partition reactivate is performed. Deferred
and/or Partition-Deferred
fixes,
if any, will be identified in the "Firmware Update Descriptions" table
of this document. For these types of fixes (Deferred and/or
Partition-Deferred) within a service pack, only the
fixes
in the service pack which cannot be concurrently activated are
deferred.
Note: The file names and service pack levels used in the
following
examples are for clarification only, and are not necessarily levels
that
have been, or will be released.
System firmware file naming convention:
01AHXXX_YYY_ZZZ
- XXX is the release level
- YYY is the service pack level
- ZZZ is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service pack
level
(YYY and ZZZ) are only unique within a release level (XXX). For
example,
01AH330_067_045 and 01AH340_067_053 are different service
packs.
An installation is disruptive if:
- The release levels (XXX) are different.
Example: Currently installed release is AH330, new release is AH340
- The service pack level (YYY) and the last disruptive
service
pack level (ZZZ) are the same.
Example: AH330_120_120 is disruptive, no matter what level of AH330 is
currently
installed on the system
- The service pack level (YYY) currently installed on the system is
lower
than the last disruptive service pack level (ZZZ) of the service pack
to
be installed.
Example: Currently installed service pack is AH330_120_120 and
new service pack is AH330_152_130
An installation is concurrent if:
- The release level (XXX) is the same, and
- The service pack level (YYY) currently installed on the
system
is
the same or higher than the last disruptive service pack level
(ZZZ)
of the service pack to be installed.
Example: Currently installed service pack is AH330_126_120,
new service pack is AH330_143_120.
Filename |
Size |
Checksum |
01AH760_078_043.rpm |
51513061
|
41801
|
Note: The Checksum can be found by running the AIX sum command against the rpm file
(only the first 5 digits are listed).
ie: sum 01AH760_078_043.rpm
AH760
For Impact, Severity and other Firmware definitions, Please
refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
The complete Firmware Fix History for this
Release Level can be
reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/AH-Firmware-Hist.html
|
AH760_078_043 / FW760.40
01/22/14 |
Impact:
Availability Severity: SPE
New Features and Functions
- Support was added in Advanced System Management Interface
(ASMI) to facilitate capture and reporting of debug data for system
performance problems. The "System Service Aids/Performance
Dump" menu was added to ASMI to perform this function.
- Support was dropped for Secured Socket Layer (SSL) protocol
version 2 and SSL weak and medium cipher suites in the service
processor web server (Lighttpd) . Unsupported web browser
connections to the Advanced System Management Interface (ASMI) secured
port 443 (using https://) will now be rejected if those browsers do not
support SSL version 3. Supported web browsers for Power7 ASMI are
Netscape (version 9.0.0.4), Microsoft Internet Explorer (version 7.0),
Mozilla Firefox (version 2.0.0.11), and Opera (version 9.24).
- Support was added in Advanced System Management Interface
(ASMI) "System Configuration/Firmware Update Policy" menu to detect and
display the appropriate Firmware Update Policy (depending on whether
system is HMC managed) instead of requiring the user to select the
Firmware Update Policy. The menu also displays the "Minimum Code
Level Supported" value.
System firmware changes that affect all systems
- A problem was
fixed that caused a memory leak of 50 bytes of service processor memory
for every call home operation. This could potentially cause an
out of memory condition for the service processor when running over an
extended period of time without a reset.
- A problem was fixed that caused a L2 cache error to not
guard out the faulty processor, allowing the system to checkstop again
on an error to the same faulty processor.
- A problem was fixed that prevented a GX adapter from being
added to an empty slot for location code P1-C3 using a MES add when the
system was powered off. The P1-C3 location code was not provided
as candidate location for the GX add in the Service Focal Point on the
management console.
- A problem was fixed that prevented the clear of the file on
the service processor that contains partition data when the Advanced
Management System Interface (ASMI) was used to "Reset Server Firmware
Settings" from the Factory Configuration menu. This problem
caused the HMC managed system to go into the recovery state.
- A problem was fixed that caused a HMC code update failure
for the FSP on the accept operation with SRC B1811402 or FSP is unable
to boot on the updated side.
- A problem was fixed that caused a system checkstop during
hypervisor time keeping services.
- A problem was fixed that caused a built-in self test (BIST)
for GX slots to create corrupt error log values that core dumped the
service processor with a B18187DA. The corruption was caused by a
failure to initialize the BIST array to 0 before starting the tests.
- The firmware was enhanced to display on the management
console the correct number of concurrent live partition mobility (LPM)
operations that is supported.
- A problem was fixed that caused a 1000911E platform event
log (PEL) to be marked as not call home. The PEL is now a call
home to allow for correction. This PEL is logged when the
hypervisor has changed the Machine Type Model Serial Number (MTMS) of
an external enclosure to UTMP.xxx.xxxx because it cannot read the vital
product data (VPD), or the VPD has invalid characters, or if the MTMS
is a duplicate to another enclosure.
- A problem was fixed that caused a SRC B7006A72 calling out
the adapter and the I/O Planar.
- A problem was fixed that caused the system attention LED
to be lit without a corresponding SRC and error log for the
event. This problem typically occurs when an operating system on
a partition terminates abnormally.
- A problem was fixed during resource dump processing that
caused a read of an invalid system memory address and a SRC
B181C141. The invalid memory reference resulted from the service
processor incorrectly referencing memory that had been relocated by the
hypervisor.
- DEFERRED: A
problem was fixed that caused a system checkstop with SRC B113E504 for
a recoverable hardware fault. This deferred fix addresses a
problem that has a very low probability of occurrence. As such
customers may wait for the next planned service window to activate the
deferred fix via a system reboot.
- A problem was fixed that prevented a HMC-managed system
from being converted to manufacturing default configuration (MDC) mode
when the management console command "lpcfgop -m <server> -o
clear" failed to create the default partition. The management
console went to the incomplete state for this error.
- A problem was fixed that caused the slot index to be
missing for virtual slot number 0 for the dynamic reconfiguration
connector (DRC) name for virtual devices. This error was visible
from the management console when using commands such as "lshwres -r
virtualio --rsubtype slot -m machine" to show the hardware resources
for virtual devices.
- A problem during a dynamic logical partitioning (DLPAR)
memory operation was fixed that caused BA250020 SRCs to be logged
unnecessarily for the AIX partition. There were no memory errors
for the partition.
- DEFERRED: A
problem was fixed that caused a system checkstop during hypervisor time
keeping services. This deferred fix addresses a problem that has
a very low probability of occurrence. As such customers may wait
for the next planned service window to activate the deferred fix via a
system reboot.
- A problem was fixed that caused frequent SRC B1A38B24 error
logs with a call home every 15 seconds when service processor network
interfaces were incorrectly configured on the same subnet. The
frequency of the notification of the network subnet error has been
reduced to once every 24 hours.
- Help text for the Advanced System Management Interface
(ASMI) "System Configuration/Hardware Deconfiguration/Clear All
Deconfiguration Errors" menu option was enhanced to clarify that when
selecting "Hardware Resources" value of "All hardware resources", the
service processor deconfiguration data is not cleared. The
"Service processor" must be explicitly selected for that to be cleared.
System firmware changes that affect certain systems
- On systems running
Dynamic Platform Optimizer (DPO) , a problem was fixed that
caused an incorrect placement of dedicated processors for partitions
larger than a single chip. When this occurs, the performance is
impacted over what would have been gained with proper placement.
- On systems with a redundant service processor, a problem
was fixed that caused fans to run at a high-speed after a failover to
the sibling service processor.
- On systems with a redundant service processor, a problem
was fixed that caused a guarded sibling service processor
deconfiguration details to not be able to be shown in the Advanced
System Management Interface (ASMI).
- On systems with a redundant service processor, a problem
was fixed that caused a SRC B150D15E to be erroneously logged after a
failover to the sibling service processor.
- On systems running Dynamic Platform Optimizer (DPO) with no
free memory, a problem was fixed that caused the management
console lsmemopt command to report the wrong status of completed with
no partitions affected. It should have indicated that DPO failed
due to insufficient free memory. DPO can only run when there is
free memory in the system.
- On systems with partitions using physical shared processor
pools, a problem was fix that caused partition hangs if the shared
processor pool was reduced to a single processor.
- On systems with turbo-core enabled that are a target of
logical partition migration (LPM), a problem was fixed where
cache properties were not recognized and SRCs BA280000 and BA250010
reported.
- On systems involved in a series of consecutive logical
partition migration (LPM) operations, a memory leak problem was fixed
in the run time abstraction service (RTAS) that caused a partition run
time AIX crash with SRC 0c20. Other possible symptoms include
error logs with SRC BA330002 (RTAS memory allocation failure).
- A problem was fixed in the run-time abstraction services
(RTAS) extended error handling (EEH) for fundamental reset that caused
partitions to crash during adapter updates. The fundamental reset
of adapters now returns a valid return code. The adapter drivers
using fundamental reset affected by this fix are the following:
o QLogic PCIe Fibre Channel adapters (combo card)
o IBM PCIe Obsidian
o Emulex BE3-based ethernet adapters
o Broadcom-based PCIe2 4-port 1Gb ethernet
o Broadcom-based FlexSystem EN2024 4-port 1Gb ethernet for compute node
- On systems that have configurations that support all the
types of Capacity On Demand
(Perm/OnOff/Trial/Utility-Processor,Perm.OnOff/Trial-Memory), a problem
was fixed to eliminate repeated B7005300 error logs caused by
hypervisor asset protection processes using slightly more memory than
promised.
- On systems with a redundant service processor, a problem
was fixed where the service processor allowed a clock failover to occur
without a SRC B158CC62 error log and without a hardware deconfiguration
record for the failed clock source. This resulted in the system
running with only one clock source and without any alerts to warn that
clock redundancy had been lost.
- On systems running Dynamic Platform Optimizer (DPO) with
one or more unlicensed processors, a problem was fixed where the system
performance was significantly degraded during the DPO operation.
The amount of performance degradation was more for systems with larger
numbers of unlicensed processors.
- On systems with one memory clock deconfigured, a problem
was fixed where the system failed to IPL using the second memory clock
with SRCs B158CC62 and B181C041 logged.
Concurrent hot add/repair maintenance firmware fixes
- A problem was fixed that caused a concurrent hot add/repair
maintenance operation to fail on an erroneously logged error for the
service processor battery with SRCs B15A3303, B15A3305, and
B181EA35 reported.
- A problem was fixed that caused a concurrent processor
exchange to terminate during node deactivation with SRC B1814616.
- A problem was fixed that caused SRC B15A3303 to be
erroneously logged as a predictive error on the service processor
sibling after a successful concurrent repair maintenance operation for
the real-time clock (RTC) battery.
- A problem was fixed that caused Capacity on Demand (COD)
"Out of Compliance" messages during concurrent maintenance operations
when the system was actually in compliance for the licensed amount of
resources in use.
|
AH760_069_043 / FW760.31
07/25/13 |
Impact: Performance
Severity: ATT
System firmware changes that affect certain systems
- On systems running
Dynamic Platform Optimizer (DPO) , a problem was fixed that
caused an incorrect placement of dedicated processors for partitions
larger than a single chip. When this occurs, the performance is
impacted over what would have been gained with proper placement.
|
AH760_068_043 / FW760.30
06/24/13 |
Impact:
Availability Severity: SPE
System firmware changes that affect all systems
- A problem was fixed
that caused a service processor dump to be generated with SRC B18187DA
"NETC_RECV_ER" logged.
- A problem was fixed that was caused by an attempt to modify
a virtual adapter from the management console command line when the
command specifies it is an Ethernet adapter, but the virtual ID
specified is for an adapter type other than Ethernet. The managed
system has to be rebooted to restore communications with the management
console when this problem occurs; SRC B7000602 is also logged.
- The Hypervisor was enhanced to allow the system to continue
to boot using the redundant data chip on the anchor (VPD) card, instead
of stopping the Hypervisor boot and logging SRC B7004715, when
the primary data chip on the anchor card has been corrupted.
- A problem was fixed that caused a migrated partition to
have to rebooted on the target system.
- A problem was fixed that caused a performance loss after a
configuration change, such as un-licensing a processor, because the
Hypervisor is unable to dispatch a partition to a shared processor.
- A problem was fixed that may cause inaccurate processor
utilization reporting.
- A problem was fixed that caused erroneous A70047xx SRCs to
be logged that called out the Anchor (VPD) card. This led
to unnecessary replacements of the Anchor card.
System firmware changes that affect certain systems
- On systems running
Active Memory Sharing (AMS) partitions, a problem was fixed that may
arise due to the incorrect handling of a return code in an error path
during the logical partition migration (LPM) of an AMS partition.
- A problem was fixed that caused the On/Off Capacity on
Demand (CoD) entitlement to erroneously go to zero when the system
firmware was upgraded from the AH730 release to the AH760 release.
- On systems running Dynamic Platform Optimization (DPO), a
problem was fixed that caused the current DPO score for a partition to
be incorrect. When this occurs, it looks like DPO would not
improve performance when in fact it would improve the performance.
Concurrent hot add/repair maintenance firmware fixes
- A problem was
fixed that caused a concurrent hot add/repair maintenance
operation to time out and fail when the system controller (service
processor) gets bogged down.
- On systems in which there are no processors in the shared
processor pool, a problem was fixed that caused the Hypervisor to
become unresponsive (the service processor starts logging time-out
errors against the Hypervisor, and the HMC can no longer talk to the
Hypervisor) during a concurrent hot add/repair maintenance
operation. SRC B182953C will also be called home.
|
AH760_062_043 / FW760.20
02/27/13 |
Impact: Availability
Severity: SPE
System firmware changes that affect all systems
- A problem was fixed
that caused a card (and its children) that was removed after the system
was booted to continue to be listed in the guard menus in the Advanced
System Management Interface (ASMI).
- A problem was fixed that caused a firmware update to fail
with SRC B1818A0F.
- A problem was fixed that caused a partition to become
unresponsive when the AIX command "update_flash -s" is run.
- A problem was fixed that caused the service processor (or
system controller) to crash when it boots from the new level during a
concurrent firmware installation.
- A problem was fixed that caused SRC B1812A40 to be
erroneously logged; a memory DIMM and the symbolic FRU AMBTEMP
were listed in the FRU list.
System firmware changes that affect certain systems
- On systems running
iSCSI, a problem was fixed that caused pinging from the iSCSI menu in
the System Management Services (SMS) to fail.
- On a partition with a large number of potentially bootable
devices, a problem was fixed that caused the partition to fail to boot
with a default catch, and SRC BA210000 may also be logged.
- On a system running a Live Partition Mobility (LPM)
operation, a problem was fixed that caused the partition to
successfully appear on the target system, but hang with a 2005 SRC.
- On a partition with the virtual Trusted Platform Module
(vTPM) enabled, a problem was fixed that caused errors to occur when
the memory assigned to the partition was changed.
- On a partition with the virtual Trusted Platform Module
(vTPM) enabled, a problem was fixed that caused the partition to stop
functioning after certain operations. When this problem occurs,
the client partition may not power off.
- On a system using the modem/serial port on the service
processor, a problem was fixed that caused a service processor dump
(with SRC B181EF88 logged) to be erroneously generated when the
connection was dropped.
- On systems that support all types of both memory and
processor Capacity on Demand (CoD) operations, and on which CoD
operations are frequently performed, the firmware was enhanced to
reduce the number of informational SRC B7005300 logged.
- A problem was fixed that caused the sibling system
controller state to show up as "unknown" in the service processor error
log if a code synchronization problem was detected after a system
controller was replaced.
- On a partition with the virtual Trusted Platform Module
(vTPM) enabled, a problem was fixed that caused SRC B200F00F to be
logged when the partition was resumed after hibernation.
- On a partition with the virtual Trusted Platform Module
(vTPM) enabled, the Hypervisor was enhanced to display (on the
management console) the minimum maximum memory required to support the
partition.
- On systems running AIX or Linux, a problem was fixed that
caused a partition to fail to boot with SRC CA260203. This
problem also can cause concurrent firmware updates to fail.
- On systems with TurboCore processors and unlicensed
processors, a problem was fixed that caused the output of the AIX
lparstat command for "Active Physical CPUs in system" to be incorrect.
Concurrent hot add/repair maintenance firmware fixes
- A problem was fixed that caused a concurrent hot add/repair
maintenance operation to fail due to an FSP reset.
- On large system configurations, a problem was fixed that
caused concurrent hot add/repair maintenance operations to fail.
- On large system configurations running hundreds of
partitions, a problem was fixed that caused the managed system to go to
the incomplete state on the HMC during a concurrent hot add/repair
maintenance operation.
- A problem was fixed that caused a concurrent hot add/repair
maintenance operation to fail if a memory channel failure on the CEC
was followed by a service processor reset/reload.
- A problem was fixed that caused a concurrent hot add/repair
maintenance operation to fail when run after a service processor
reset/reload.
|
AH760_043_043
11/21/12 |
Impact:
New
Severity: New
New Features and Functions
- Support for the GX++ dual-port 10GB Ethernet/Fibre Channel
over Ethernet (FCoE) adapter, feature code (F/C) EN22.
- Support for the GX++ dual-port Fibre Channel adapter,
feature code (F/C) EN23.
- Support for 0.05 processor granularity.
- Support for 64GB DIMMs.
- Support for Dynamic Platform Optimizer (DPO).
- The Hypervisor was enhanced to enforce broadcast storm
prevention between the primary and backup SEAs (Shared Ethernet
Adapters). This fix requires VIOS 2.2.2.0 or later on all VIOS
partitions with SEA devices.
Additional
Requirements:
- FC EB33,
available at no charge, needs to be ordered for DPO
- Partitions included in DPO optimization need to running an
affinity aware version of the operating system OR need to be restarted
after DPO completes. If not, partitions can be excluded from
participation in optimization through a command line option on the optmem command.
Notes:
- Affinity aware operating system (OS) levels that support DPO:
◦ AIX 6.1 TL8 or later
◦ AIX 7.1 TL2 or later
◦ VIOS 2.2.2.0
◦ IBM i 7.1 PTF MF56058
- No integrated support for DPO in current RHEL or SUSE Enterprise
versions. Linux partitions can either be excluded from participation in
optimization or restarted after DPO operation completes.
|
4.0
How to Determine Currently Installed Firmware Level
You can view the server's current firmware level on the Advanced System
Management Interface (ASMI) Welcome pane. It appears in the top right
corner.
Example: AH760_123.
5.0 Downloading
the
Firmware Package
Follow the instructions on Fix Central. You must read and agree to
the
license agreement to obtain the firmware packages.
Note: If your HMC or SDMC is not internet-connected you will need
to
download
the new firmware level to a CD-ROM or ftp server.
6.0 Installing the
Firmware
The method used to install new firmware will depend on the release
level
of firmware which is currently installed on your server. The release
level
can be determined by the prefix of the new firmware's filename.
Example: AHXXX_YYY_ZZZ
Where XXX = release level
- If the release level will stay the same (Example: Level
AH330_075_075
is
currently installed and you are attempting to install level
AH330_081_075)
this is considered an update.
- If the release level will change (Example: Level AH330_081_075 is
currently
installed and you are attempting to install level AH340_096_096) this
is
considered an upgrade.
Instructions for installing firmware updates and upgrades can be found
at http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7ha1/updupdates.htm
IBM
i Systems:
See "IBM Server Firmware and HMC Code Wizard":
http://www-912.ibm.com/s_dir/slkbase.NSF/DocNumber/408316083
NOTE: For all systems running with
the IBM i Operating System, the following IBM i PTFs must be applied to
all IBM i partitions prior to installing AH760_078:
- V7R1M0 - MF51869
- V6R1M1 - MF51864
These PTFs can be ordered through Fix Central.
7.0 Firmware History
The complete Firmware Fix History for this Release level can be
reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/AH-Firmware-Hist.html