Power7 Mid-Range Systems Firmware

Applies to: 9117-MMB and 9179-MHB

This document provides information about the installation of Licensed Machine or Licensed Internal Code, which is sometimes referred to generically as microcode or firmware.


Contents


1.0 Systems Affected

This package provides firmware for Power 770 (9117-MMB)  and Power 780 (9179-MHB)  servers only.

The firmware level in this package is:

1.1 Minimum HMC Code Level

This section is intended to describe the "Minimum HMC Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the HMC level must be equal to or higher than the "Minimum HMC Code Level" before starting the system firmware update.  If the HMC managing the server targeted for the System Firmware update is running a code level lower than the "Minimum HMC Code Level" the firmware update will not proceed.

The Minimum HMC Code level for this firmware is:  HMC V7 R7.3.0 (PTF MH01255 or MH01256) with PTF MH01257 (Mandatory efix).

For information concerning HMC releases and the latest PTFs,  go to the following URL to access Fix Central.

http://www-933.ibm.com/support/fixcentral/

For specific fix level information on key components of IBM Power Systems running the AIX, IBM i and Linux operating systems, we suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home

NOTE: You must be logged in as hscroot in order for the firmware installation to complete correctly.

1.2 Minimum SDMC Code Level

This section is intended to describe the "Minimum Systems Director Management Console (SDMC) Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the SDMC level must be equal to or higher than the "Minimum SDMC Code Level" before starting the system firmware update.  If the SDMC managing the server targeted for the System Firmware update is running a code level lower than the "Minimum SDMC Code Level" the firmware update will not proceed.

The Minimum SDMC Code level for this firmware is:  SDMC V6 R7.3.0 with Mandatory PTF MF53082.

For information concerning SDMC releases and the latest PTFs,  go to the following URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/

For specific fix level information on key components of IBM Power Systems running the AIX, IBM i and Linux operating systems, we suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home

2.0 Important Information

IPv6 Support and Limitations

IPv6 (Internet Protocol version 6) is supported in the System Management Services (SMS) in this level of system firmware. There are several limitations that should be considered.

When configuring a network interface card (NIC) for remote IPL, only the most recently configured protocol (IPv4 or IPv6) is retained. For example, if the network interface card was previously configured with IPv4 information and is now being configured with IPv6 information, the IPv4 configuration information is discarded.

A single network interface card may only be chosen once for the boot device list. In other words, the interface cannot be configured for the IPv6 protocol and for the IPv4 protocol at the same time.

Concurrent Firmware Updates

Concurrent system firmware update is only supported on HMC or SDMC Managed Systems only.

Memory Considerations for Firmware Upgrades

Firmware Release Level upgrades and Service Pack updates may consume additional system memory.
Server firmware requires memory to support the logical partitions on the server. The amount of memory required by the server firmware varies according to several factors.
Factors influencing server firmware memory requirements include the following:
Generally, you can estimate the amount of memory required by server firmware to be approximately 8% of the system installed memory. The actual amount required will generally be less than 8%. However, there are some server models that require an absolute minimum amount of memory for server firmware, regardless of the previously mentioned considerations.

Additional information can be found at:
  http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hat/iphatlparmemory.htm


3.0 Firmware Information and Description

Use the following examples as a reference to determine whether your installation will be concurrent or disruptive.

For systems that are not managed by an HMC or SDMC, the installation of system firmware is always disruptive.

Note: The concurrent levels of system firmware may, on occasion, contain fixes that are known as Deferred and/or Partition-Deferred. Deferred fixes can be installed concurrently, but will not be activated until the next IPL. Partition-Deferred fixes can be installed concurrently, but will not be activated until a partition reactivate is performed.  Deferred and/or Partition-Deferred fixes, if any, will be identified in the "Firmware Update Descriptions" table of this document. For these types of fixes (Deferred and/or Partition-Deferred) within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred.

Note: The file names and service pack levels used in the following examples are for clarification only, and are not necessarily levels that have been, or will be released.

System firmware file naming convention:

01AMXXX_YYY_ZZZ

NOTE: Values of service pack and last disruptive service pack level (YYY and ZZZ) are only unique within a release level (XXX). For example, 01AM720_067_045 and 01AM740_067_053 are different service packs.

An installation is disruptive if:

Example: Currently installed release is AL710, new release is AM720 Example: AM720_120_120 is disruptive, no matter what level of AM720 is currently
installed on the system Example: Currently installed service pack is AM720_120_120 and new service pack is AM720_152_130

An installation is concurrent if:

The release level (XXX) is the same, and
The service pack level (YYY) currently installed on the system is the same or higher than the last disruptive service pack level (ZZZ) of the service pack to be installed.

Example: Currently installed service pack is AM720_126_120,  new service pack is AM720_143_120.

Firmware Information and Update Description

 
Filename Size Checksum
01AM730_035_035.rpm 38111268 54212

Note: The Checksum can be found by running the AIX sum command against the rpm file (only the first 5 digits are listed).
ie: sum 01AM730_035_035.rpm

AM730
For Impact, Severity and other Firmware definitions, Please refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
AM730_035_035

05/27/11
Impact:  New        Severity:  New

New Features and Functions

  • Support for the attachment of a System Director Management Console (SDMC).
  • Support for up to 1000 partitions on 9117-MMB, 9179-MHB, and 9119-FHB systems.
  • Support for IBM i live partition hibernation.
  • Support for server platform system dumps (SYSDUMP files) larger than 4GB.
  • Support for power savings settings for certain partitions and the system processor pool.
  • Support for the feature code (F/C) 5887 media drawer.
  • Support for remote restart of partitions.


4.0 How to Determine Currently Installed Firmware Level

For HMC managed systems:  From the HMC, select Updates in the navigation (left-hand) pane, then view the current levels of the desired server(s).

For SDMC managed systems:  From the SDMC Welcome page, select the desired server(s), then select Release Management, then select Power System Firmware Management. Click Gather Target Information, then view the current levels of the desired server(s). 
NOTE:
  If Inventory has not previously been collected, a message will be displayed indicating to "View and Collect Inventory" to proceed.

Alternately, use the Advanced System Management Interface (ASMI) Welcome pane. The current server firmware  appears in the top right corner. Example: AM710_yyy.


5.0 Downloading the Firmware Package

Follow the instructions on Fix Central. You must read and agree to the license agreement to obtain the firmware packages.

Note: If your HMC or SDMC is not internet-connected you will need to download the new firmware level to a CD-ROM or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: AMXXX_YYY_ZZZ

Where XXX = release level

Instructions for installing firmware updates and upgrades can be found at http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7ha1/updupdates.htm

IBM i Systems:
See "Server Firmware and HMC Wizard":
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes

NOTE: For systems running with the IBM i Operating System, the following IBM i PTFs must be applied to all IBM i partitions prior to installing AM730_035:

7.0 Firmware History

The Firmware History can be reviewed at the following url:

http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/AM-Firmware-Hist.html

8.0 Change History

Date
Description
October 17, 2011 Added the NOTE in the IBM i Systems heading in section 6.0
June 20, 2011
Updates for SDMC support