Power6 High-End Power Subsystem Firmware
Applies to: 9125-F2A
This document provides information about the installation of
Licensed
Machine or Licensed Internal Code, which is sometimes referred to
generically
as microcode or firmware.
Contents
This package provides firmware for Power 575 (9125-F2A) Servers only.
Do not use on any other systems.
The firmware level in this package is:
HMC-Managed Systems
This firmware level requires HMC V7 R3.4.0.
Go to the following URL to access the HMC code packages:
NOTE: You must be logged in as hscroot in order for the
firmware installation to complete correctly.
Installing Power Subsystem Firmware and System Firmware
Atention: 9125-F2A servers should be evaluated for ECA845 installation
prior to performing firmware upgrades. Contact your service provider for more
information about ECA845. If firmware must be upgraded prior to the
installation of ECA845, use the following special instructions:
Firmware installations should be performed on an entire managed frame, and
all managed systems
housed in that frame, at one time. The following instructions can
be used to install firmware on
one managed frame and all of the managed systems that it houses. The
instructions can be
repeated as many times as needed until all firmware has been installed on
all managed frames.
1) Power off all managed 9125-F2A systems in the managed frame.
2) Reinstall the current system firmware level on all managed systems in
the managed frame:
The following command can be used to determine the current
firmware level:
lslic -t sys -m <managedsystem_1> -F
activated_level
The following command will retrieve and reinstall the current
firmware level on
one managed system:
updlic -o a -m <managedsystem_1> -t
sys -l <current_fsp_level> -r <repos>
<current_fsp_level> is the level determined
with the lslic command.
<repos> is the location of the firmware
such as "-r dvd", "-r ibmwebsite", etc.
Additional parameters might be required,
depending on the repository selection.
If the firmware has already been copied onto
the HMC, the HMC hard drive (-r disk)
should be used as the repository.
After the firmware has been copied onto the HMC, the HMC hard
drive (-r disk) should
be used as the repository to update the remaining managed systems:
updlic -o a -m <managedsystem_2> -t
sys -l <current_fsp_level> -r disk
updlic -o a -m <managedsystem_3> -t
sys -l <current_fsp_level> -r disk
......
updlic -o a -m <managedsystem_N> -t
sys -l <current_fsp_level> -r disk
These commands can be run in the background in parallel to
speed up the installation of the firmware.
Wait for all updlic commands to complete before proceeding
to step 3.
3) Clear any locks that are held on the managed frame by issuing this command:
rmlock -e <managedframe>
4) Reboot the HMC.
5) Install and activate new firmware on the managed frame and all managed
systems in that frame.
Using the HMC GUI interface, click on "Updates" in the navigation
(left-hand) pane. Click on the
checkbox beside all managed systems in the same managed frame,
and click on "Upgrade Licensed
Internal Code to a new release".
After clicking "OK" on the readiness check panel, select the
repository where the firmware files
can be found and click "OK". Select the new managed frame
(02EP340_041) and managed system
(01ES340_042) firmware levels from the selection panels that
are displayed.
Accept the license agreement and click on "OK" in the confirmation
panels to start the firmware installation.
6) Power on the managed systems.
Use the following example as a reference to determine whether your
installation will be concurrent or disruptive.
Note: The file names and service pack levels used in
the following examples are for clarification only, and are not
necessarily levels that have been, or will be released.
Power Subsystem firmware file naming convention:
02EPXXX_YYY_ZZZ
- XXX is the release level
- YYY is the service pack level
- ZZZ is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service
pack level (YYY and ZZZ) are only unique
within a release level (XXX). For example, 02EP330_067_045 and
02EP340_067_053 are different
service packs.
An installation is disruptive if:
- The release levels (XXX) are different.
Example: Currently installed release is EP330, new release is
EP340
- The service pack level (YYY) and the last
disruptive service pack level (ZZZ) are equal.
Example: EP330_120_120 is disruptive, no matter what level of
EP330 is currently
installed on the system
- The service pack level (YYY) currently installed on the system
is lower than the last disruptive service pack level (ZZZ) of the
service pack to be installed.
Example: Currently installed service pack is EP330_120_120 and
new service pack is EP330_152_130
An installation is concurrent if:
- The service pack level (YYY) is higher than the service
pack level currently installed on your system.
Example: Currently installed service pack is EP330_126_120,
new service pack is EP330_143_120.
Firmware Information and Update Description
Filename |
Size |
Checksum |
02EP340_132_041.rpm |
14,336,531 |
16693 |
You can view the frame's current firmware level on the Advanced System
Management Interface (ASMI) Welcome pane. It appears in the top
right
corner. Example: EP330_029.
Follow the instructions on the web page. You must read and agree to
the license agreement to obtain the firmware packages.
Note: If your HMC is not internet-connected you will need to
download the new firmware level to a CD-ROM or ftp server.
The method used to install new firmware will depend on the release
level of firmware which is currently installed on your server. The
release level can be determined by the prefix of the new firmware's
filename.
Example: EPXXX_YYY_ZZZ
Where XXX = release level
- If the release level will stay the same (Example: Level
EP330_075_075 is currently installed and you are attempting to
install level EP330_081_075) this is considered an update.
- If the release level will change (Example: Level EP330_081_075
is currently installed and you are attempting to install level
EP340_096_096) this is considered an upgrade.
Instructions for installing firmware updates and upgrades can be found
at http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/ipha1/updateschapter.htm