Power6 Mid-Range Firmware
Applies to: 9117-MMA , 9406-MMA, and 8234-EMA
This document provides information about the installation of
Licensed
Machine or Licensed Internal Code, which is sometimes referred to
generically
as microcode or firmware.
Contents
1.0 Systems Affected
This package provides firmware for System p 570 (9117-MMA), System i570
(9406-MMA), Power 570 (9117-MMA), and Power 560 (8234-EMA) servers
only.
The firmware level in this package is:
1.1 Minimum HMC Code Level
This section is intended to describe the "Minimum HMC Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the HMC level must be
equal to or higher than the "Minimum HMC Code Level" before starting
the system firmware update. If the HMC managing the server
targeted for the System Firmware update is lower than the "Minimum HMC
Code Level" the firmware update will not proceed.
The Minimum HMC Code level for this firmware is: HMC V7 R3.5.0 with PTFs MH01212 and
MH01217 (or higher).
Although the Minimum HMC Code level for this firmware is listed
above, HMC level V7 R3.5.0 with PTF MH01238
(Service Pack 3), or
higher is
suggested for
this
firmware level.
For specific fix level information on key components of IBM
Power
Systems running the AIX, IBM i and Linux operating systems, we suggest
using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home
For information concerning HMC releases and the latest PTFs,
go
to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/
NOTE: You must be logged in as hscroot in order for the
firmware
installation to complete correctly.
2.0 Cautions
and Important
Information
2.1 Cautions
Downgrading firmware from any
given release level to an earlier release level is not recommended.
If you feel that it is
necessary to downgrade the firmware on
your system to an earlier release level, please contact your next level
of support.
Upgrading from EM320_031 to EM350_xxx
If your current level of firmware is EM320_031
you
must install any higher level of EM320 before upgrading your firmware
to
this level.
Upgrading from EM310_xxx to EM350_yyy
If your current level of firmware is
EM310_xxx,
you must install EM320_040 or higher before upgrading your firmware to
this level.
2.2 Important Information
IPv6 Support and Limitations
IPv6 (Internet Protocol version 6) is supported in the System
Management
Services (SMS) in this level of system firmware. There are several
limitations
that should be considered.
When configuring a network interface card (NIC) for remote IPL, only
the most recently configured protocol (IPv4 or IPv6) is retained. For
example,
if the network interface card was previously configured with IPv4
information
and is now being configured with IPv6 information, the IPv4
configuration
information is discarded.
A single network interface card may only be chosen once for the boot
device list. In other words, the interface cannot be configured for the
IPv6 protocol and for the IPv4 protocol at the same time.
HMC-Managed Systems
For
model 560 and model 570 systems, this
firmware level provides an enhancement to improve the reporting of
power
supply fan
failures. These failures will be identified via the new System
Reference codes (listed below). Until the HMC support for
these new SRC's is available (end of October 2010), the SRC
definitions can be reviewed at http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/ipha6_p5/x1xxx.htm
New SRC codes
|
Power Supply
E1 |
Power Supply
E2 |
Comments |
New SRC for "predictive" fan
fault |
1100151E |
1100152E |
The power supply fan at location
Un-E1 / Un-E2 stopped temporarily but recovered.
Replace the power
supply as
soon as possible before the fan fails permanently. |
New SRC for hard fan fault |
1100151F |
1100152F |
The power supply fan at location
Un-E1 / Un-E2 failed. Replace the power supply as soon as
possible. |
Memory Considerations for Firmware Upgrades
The increase in memory used by the firmware is due to the additional
functionality
in later firmware releases.
3.0 Firmware
Information
and Description
Use the following examples as a reference to determine whether your
installation
will be concurrent or disruptive.
For systems that are not managed by an HMC, the installation of
system
firmware is always disruptive.
Note: The concurrent levels of system firmware may, on occasion,
contain
fixes that are known as deferred. These deferred fixes can be installed
concurrently, but will not be activated until the next IPL. Deferred
fixes,
if any, will be identified in the "Firmware Update Descriptions" table
of this document. For deferred fixes within a service pack, only the
fixes
in the service pack which cannot be concurrently activated are
deferred.
Note: The file names and service pack levels used in the
following
examples are for clarification only, and are not necessarily levels
that
have been, or will be released.
System firmware file naming convention:
01EMXXX_YYY_ZZZ
- XXX is the release level
- YYY is the service pack level
- ZZZ is the last disruptive service pack level
-
NOTE: Values of service pack and last disruptive service pack
level
(YYY and ZZZ) are only unique within a release level (XXX).
For example, 01EM310_067_045 and 01EM320_067_053 are different
service packs.
An installation is disruptive if:
- The release levels (XXX) are different.
Example: Currently installed release is EM310, new release is EM320
- The service pack level (YYY) and the last disruptive
service
pack level (ZZZ) are the same.
Example: EM310_120_120 is disruptive, no matter what level of EM310 is
currently
installed on the system
- The service pack level (YYY) currently installed on the system is
lower
than the last disruptive service pack level (ZZZ) of the service pack
to
be installed.
Example: Currently installed service pack is EM310_120_120 and
new service pack is EM310_152_130
An installation is concurrent if:
- The release level (XXX) is the same, and
- The service pack level (YYY) currently installed on the
system
is
the same or higher than the last disruptive service pack level
(ZZZ)
of the service pack to be installed.
Example: Currently installed service pack is EM310_126_120,
new service pack is EM310_143_120.
Firmware Information and Update Description
For information about previous firmware release levels, see
Section 7.0 Firmware History.
Filename |
Size |
Checksum |
01EM350_085_038.rpm |
23773324
|
40716
|
Note: The Checksum can be found by running the AIX sum command against the rpm file
(only the first 5 digits are listed).
ie: sum 01EM350_085_038.rpm
EM350
For Impact, Severity and other Firmware definitions, Please
refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
|
EM350_085_038
10/26/10
|
Impact: Availability
Severity: HIPER
- High Impact/PERvasive, Should be installed as soon as
possible.
System firmware changes that affect all systems
- HIPER for 8234-EMA and 9117-MMA
systems: On 8234-EMA (Power 560 Express) and
9117-MMA
(Power 570) systems, the firmware has been enhanced to improve
reporting of power supply fan problems, which reduces the potential of
a unplanned system outage.
- HIPER: On
systems using the
HEA (host Ethernet adapter) function, and on which a CEC concurrent
maintenance operation that requires a node evacuation is being done,
this fix corrects an issue that has the potential to corrupt
information stored in the system memory, which may cause undetected
data errors. This issue was discovered during internal IBM
testing, and while it has not been reported on any customer systems,
IBM strongly recommends that this fix be applied to all model MMA
systems that are running AIX partitions.
- HIPER: A
problem was fixed that caused the HMC to show the server's status as
incomplete, and SRC B7000602 to be logged against SFLPHMCCMDTASK in
serviceable events. This problem can also cause the system to
crash when it occurs.
- HIPER: A
problem was fixed that caused repeated reset/reloads of the service
processor, and fail-overs, to occur after a hypervisor-initiated
reset/reload of the service processor was completed. That led to
loss of communication between the service processor and the hypervisor
(indicated by SRC B182951C).
- On 9117-MMA (Power 570) systems with 3 or 4 processor
drawers, this service pack also fixes a problem that prevented the
power supply fan speed in these drawers from adjusting to changes in
the ambient temperature.
- The firmware was
enhanced to log SRC B181D30B as informational instead of predictive.
- The firmware was enhanced to
list the attached devices when viewing the adapter information for a
partition profile on the HMC GUI.
- A problem was fixed that
caused the hypervisor to issue almost continuous reset/reload requests
to the service processor.
System firmware changes that affect certain systems
- On systems with a F/C 5802 or
5877 I/O drawer attached, the firmware was enhanced to allow the drawer
to power on with only one working offline converter assembly (OCA).
- The firmware was enhanced to
support the network installation of the IBM i operating system from the
hardware management console (HMC) command line interface (CLI).
- On systems using the IPv6
protocol, a problem was fixed that caused valid link local and unique
link local addresses to be erroneously invalidated. This
prevented the port with that address from being used for network boot
or network installation.
|
4.0
How to Determine Currently Installed Firmware Level
You can view the server's current firmware level on the Advanced System
Management Interface (ASMI) Welcome pane. It appears in the top right
corner.
Example: EM350_038.
5.0 Downloading
the
Firmware Package
Follow the instructions on the web page. You must read and agree to the
license agreement to obtain the firmware packages.
Note: If your HMC is not internet-connected you will need to
download
the new firmware level to a CD-ROM or ftp server.
6.0 Installing the
Firmware
The method used to install new firmware will depend on the release
level
of firmware which is currently installed on your server. The release
level
can be determined by the prefix of the new firmware's filename.
Example: EMXXX_YYY_ZZZ
Where XXX = release level
- If the release level will stay the same (Example: Level
EM310_075_075
is
currently installed and you are attempting to install level
EM310_081_075)
this is considered an update.
- If the release level will change (Example: Level EM320_081_075 is
currently
installed and you are attempting to install level EM340_096_096) this
is
considered an upgrade.
Instructions for installing firmware updates and upgrades can be
found at http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/ipha1/updupdates.htm
IBM i Systems
See "Server Firmware and HMC
Wizard",
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes
7.0 Firmware History
The Firmware History can be reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/EM-Firmware-Hist.html
8.0 Change History
Date
|
Description
|
June 27, 2011 |
Removed older levels from the
Firmware Information and Update Description table. Corrected a
typo in the firmware history html file (link in Section 7.0) for
firmware level EM350_063. |