Power7 Entry Systems Firmware
Applies to: 8233-E8B and 8236-E8C
This document provides information about the installation of
Licensed
Machine or Licensed Internal Code, which is sometimes referred to
generically
as microcode or firmware.
Contents
1.0
Systems Affected
This package provides firmware for Power 750 (8233-E8B) and Power
755 (8236-E8C) servers
only.
The firmware level in this package is:
1.1 Minimum HMC Code Level
This section is intended to describe the "Minimum HMC Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the HMC level must be
equal to or higher than the "Minimum HMC Code Level" before starting
the system firmware update. If the HMC managing the server
targeted for the System Firmware update is lower than the "Minimum HMC
Code Level" the firmware update will not proceed.
The Minimum HMC Code level for this firmware is: HMC V7 R7.1.0 Service Pack 2 (PTF MH01219)
or
higher.
For information concerning HMC releases and the latest PTFs,
go
to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/
NOTE: You must be logged in as hscroot in order for the
firmware
installation to complete correctly.
2.0 Cautions
and Important
Information
2.1 Cautions
Downgrading firmware from any
given release level to an earlier release level is not recommended.
If you feel that it is necessary to downgrade the firmware on
your system to an earlier release level, please contact your next level
of support.
2.2 Important
Information
IPv6 Support and Limitations
IPv6 (Internet Protocol version 6) is supported in the System
Management
Services (SMS) in this level of system firmware. There are several
limitations
that should be considered.
When configuring a network interface card (NIC) for remote IPL, only
the most recently configured protocol (IPv4 or IPv6) is retained. For
example,
if the network interface card was previously configured with IPv4
information
and is now being configured with IPv6 information, the IPv4
configuration
information is discarded.
A single network interface card may only be chosen once for the boot
device list. In other words, the interface cannot be configured for the
IPv6 protocol and for the IPv4 protocol at the same time
Concurrent Firmware Updates
Concurrent system firmware update is only supported on HMC - Managed
Systems
only.
Memory Considerations for Firmware Upgrades
The increase in memory used by the firmware is due to the additional
functionality
in later firmware releases.
3.0 Firmware
Information
and Description
Use the following examples as a reference to determine whether your
installation
will be concurrent or disruptive.
For systems that are not managed by an HMC, the installation of
system
firmware is always disruptive.
Note: The concurrent levels of system firmware may, on occasion,
contain
fixes that are known as deferred. These deferred fixes can be installed
concurrently, but will not be activated until the next IPL. Deferred
fixes,
if any, will be identified in the "Firmware Update Descriptions" table
of this document. For deferred fixes within a service pack, only the
fixes
in the service pack which cannot be concurrently activated are
deferred.
Note: The file names and service pack levels used in the
following
examples are for clarification only, and are not
necessarily levels that have been, or will be released.
System firmware file naming convention:
01ALXXX_YYY_ZZZ
- XXX is the release level
- YYY is the service pack level
- ZZZ is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service pack
level
(YYY and ZZZ) are only unique within a release level (XXX). For
example,
01AL720_067_045 and 01AL740_067_053 are different service
packs.
An installation is disruptive if:
- The release levels (XXX) are different.
Example: Currently installed release is AL710, new release is AL720
- The service pack level (YYY) and the last disruptive
service
pack level (ZZZ) are the same.
Example: AL720_120_120 is disruptive, no matter what level of AL720 is
currently
installed on the system
- The service pack level (YYY) currently installed on the
system
is
lower than the last disruptive service pack level (ZZZ) of the service
pack to be installed.
Example: Currently installed service pack is AL720_120_120 and new
service
pack is AL720_152_130
An installation is concurrent if:
The release level (XXX) is the same, and
The service pack level (YYY) currently installed on the system
is the same or higher than the last disruptive service pack level (ZZZ)
of the service pack to be installed.
Example: Currently installed service pack is AL720_126_120,
new
service pack is AL720_143_120.
Firmware Information and Update Description
Filename |
Size |
Checksum |
01AL710_083_043.rpm |
25033171
|
41766
|
Note: The Checksum can be found by running the AIX sum
command against
the rpm file (only the first 5 digits are listed).
ie: sum 01AL710_083_043.rpm
AL710
For Impact, Severity and other Firmware definitions, Please
refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
|
AL710_083_043
06/07/10 |
Impact: Serviceability
Severity: ATT
System firmware changes that affect all systems
- The firmware was enhanced to
dynamically update the IPL speed on the control (operator) panel when
the IPL speed is changed by another method.
- A problem was fixed that
caused SRC B113E504 SRCs with a description of "Undefined Error Code"
to be erroneously logged.
- The control panel option was
removed from the concurrent maintenance menu on the ASMI
(advanced system management interface). Concurrent replacement of
the control panel is not supported on this system.
- A problem was fixed that
prevented the enclosure fault roll-up LED from being lit when a fan was
pulled from the system. This problem also resulted in missing
location codes in the ASMI (advanced system management interface) menus.
- Two problems
were fixed that caused SRCs B181B8F8 and SCR B181B86A to be erroneously
logged during a mainstore dump. In both cases, the SRC being
logged prevented the mainstore dump data from being collected and
erroneously called out hardware for replacement.
- A problem was fixed the
prevented the reset/reload bit from being set correctly in a service
processor error log entry.
- A problem was fixed
that caused a call home to be erroneously made with SRC B181E911, and a
service processor dump to be taken unnecessarily.
System firmware changes that affect certain systems
- PARTITION-DEFERRED:
A problem
was fixed that caused SRC BA210000 to be erroneously logged on the
target system when a partition was moved (using Live Partition
Mobility) from a Power7 system to a Power6 system.
- A problem was fixed that
caused SRC BA280000 to be erroneously logged on the target system when
a partition was moved (using Live Partition Mobility) from a Power7
system to a Power6 system.
- On systems managed by an HMC,
a problem was fixed that caused the service processor to crash with SRC
B181720D due to an out-of-memory condition.
- On systems managed
by an HMC, a problem was fixed that caused the HMC to show a status of
"Incomplete" for the managed system, and numerous service processor
dumps to be generated.
- On systems with the Active
Energy Manager in IBM Director activated, a problem was fixed that
caused a small error in the processor usage calculations.
- A problem was fixed that
caused a system or partition running Linux to crash when the
"serv_config -l" command was run.
- On systems in an i5/OS
clustering configuration and managed by an HMC, a problem was fixed
that prevented a partition in an I/O pool from being deleted.
|
AL710_065_043
03/16/10 |
Impact: Usability
Severity: HIPER
System firmware changes that affect all systems
- A problem was fixed that caused disks that were not
bootable to be displayed in the system management services boot
menus. This problem also prevented the operating system level
from being displayed for bootable hard disks in the system management
services boot menus.
- A problem was fixed that caused the location code to be
displayed incorrectly for the embedded SAS controller.
- A problem was fixed that prevented a concurrent system dump
from being taken if a system dump was invalidated (off loaded) before
the hypervisor was fully loaded during the boot process.
- A problem was fixed that, under certain rare circumstances,
caused the system to become unresponsive and appear to hang.
- Various enhancements were made to the firmware to error
handling, and error logging, when a failure occurs in system memory.
System firmware changes that affect certain systems
- On systems running Active Energy Management, a problem was
fixed that caused Active Energy Management to inaccurately calculate
the parameters used for power throttling.
- On systems running redundant VIOS partitions, a problem was
fixed that prevented Ethernet traffic from being properly bridged
between the two partitions. This problem also prevented shared
Ethernet adapter failover from working correctly.
- On systems managed by an HMC, a problem was fixed that
caused the HMC to report that the connection to the managed system was
dropped due to problems with locks.
- On systems using IPv6 addresses, a problem was fixed that
prevented static IPv6 addresses from being removed without completely
disabling IPv6.
- On systems with two power supplies, the firmware was
enhanced such that if ac input power is removed from one power supply,
the speed of the fans in the remaining power supply will increase to
provide additional cooling.
|
AL710_043_043
02/19/10
|
Impact:
New
Severity: New
GA Level
|
4.0
How to Determine Currently Installed Firmware Level
For HMC managed systems:
From the HMC, select Updates in the navigation (left-hand) pane, then
view the current levels of the desired server(s).
For standalone system running IBM i
without an HMC:
From a command line, issue DSPFMWSTS.
For standalone system running IBM AIX
without an HMC:
From a command line, issue lsmcode.
Alternately, use the Advanced System
Management Interface (ASMI) Welcome pane. The current server
firmware appears in the top right
corner.
Example: AL710_yyy.
5.0
Downloading the Firmware Package
You must read and agree to the
license agreement to obtain the firmware packages.
Note: If your HMC is not internet-connected you will need to
download
the new firmware level to a CD-ROM or ftp server.
6.0 Installing the
Firmware
The method used to install new firmware will depend on the release
level
of firmware which is currently installed on your server. The release
level
can be determined by the prefix of the new firmware's filename.
Example: ELXXX_YYY_ZZZ
Where XXX = release level
- If the release level will stay the same (Example: Level
AL710_075_075
is
currently installed and you are attempting to install level
AL710_081_075)
this is considered an update.
- If the release level will change (Example: Level AL710_081_075 is
currently
installed and you are attempting to install level AL720_096_096) this
is
considered an upgrade.
For details on installing the firmware, perform the
following steps:
1. Go to the IBM Power System Hardware Information Center at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp
2. Select the platform and model you are working with.
3. Select from the following options:
- For details on getting firmware fixes
through the HMC:
- select Working with consoles, terminals and interfaces >
Managing the Hard Management Console > Updates > Managed System
Updates.
- For details on getting firmware fixes
through AIX, IBM i, or
Virtual I/O Server:
- select Troubleshooting, Service, and support > Getting fixes
> Getting firmware fixes.
IBM i Systems
See "Server Firmware and HMC
Wizard",
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes
7.0 Change History
Date |
Description |
Oct 05, 2010 |
- Added Cautions section 2.1
with Downgrade warning.
- Other minor documentation updates |