IBM System Storage DS Storage Manager version 11.20.x5.10 for Microsoft Windows Server 2012, Microsoft Windows Server 2008 SP2 - X64 (64bit), Windows Server 2008 R2 SP2 with HyperV Clustering edition, Windows Server 2008 SP2 - x86 (32bit), Windows Server 2003 SP2 - X64 (AMD64/EM64T) and Windows Server 2003 SP2 - x86 (32bit) edition operating system environments. Important: With controller firmware 7.86.32.00 and later, the DSM is supported on Windows 64bit ONLY. Please do not upgrade any storage subsystem to controller firmware to 7.86.32.00 or later if that storage subsystem has 32bit Windows hosts attached. A problem causing recursive reboots exists while using 7.36.08 and 7.36.12 firmware on IBM System Storage DS4000 or DS5000 systems. This problem is fixed in 7.36.14.xx and above firmware. All subsystems currently using 7.36.08 and 7.36.12 firmware MUST run a file system check tool (DbFix) before and after the firmware upgrade to 7.36.14.xx or higher. Instructions for obtaining and using DbFix are contained in the 7.36.14.xx or higher firmware package. Carefully read the firmware readme and the DbFix instructions before upgrading to firmware 7.36.14.xx or higher. For subsystems with firmware level 7.36.08 or 7.36.12, configuration changes should be avoided until a firmware upgrade to 7.36.14.xx or higher has been completed successfully. Subsystems not currently using 7.36.08 or 7.36.12 do not need to run DbFix prior to upgrading to 7.36.14.xx or higher. DbFix may be run after upgrading to 7.36.14.xx or higher, but it is not required. DbFix is only applicable to subsystems using 7.36.xx.xx or greater firmware. If problems are experienced using DbFix or the resulting message received is Check Failed, DO NOT upgrade your firmware and contact IBM support before taking any further actions. Last Update: 06/04/2015 Jun 04, 2015 - Version 11.20.x5.10 - Provide the following new functions (DS3500, DCS3700 and DCS3860) - LSIP200666301 Set Thin Provisioned Volume quota default to around 100% of virtual capacity as a limit on the expansion. - LSIP200660537 Add updated translated files to Centrin project. - LSIP200660549 SYMsdk IBM jre v70sr8 update. - Fix the following defects Severity 1 - LSIP200685091 SMInstaller failed on SLES 12 PPC host. Severity 2 - LSIP200678551 EULA.html and License Agreement are not matched. Installer only shows English. - LSIP200679297 CLI command "delete hosts" gives a syntax error. - LSIP200707694 Online drive firmware download not covered in CLI documentation - LSIP200674454 Online Help: Typo in 'Run iSCSI Target Discovery on the Host' topic Severity 3 - LSIP200717999 SMInstaller description for AIX MPIO is not correct using Microsoft MPIO description - LSIP200698734 'Show SSD Cache Statistic' command has optional parameters shown as required - LSIP200698733 'RAID Level 3' shows up in searches within MDSM help - LSIP200690603 -alertTest command and associated online help reference of this command is missing/removed. - LSIP200693893 Minimum number of trays for RAID 6 tray loss protection is wrong - Fixes in MPIO DSM 02.01.1305.1012 - LSIP200320422 Memory leak due to ds4dsm Dec 02, 2013 - Version 10.86.x5.43 - Fix the following defects Severity 2 - LSIP200378149 (CL LSIP200367053) Pre-upgrade validation check is not performed during controller firmware activation via CLI in staged - LSIP200378169 (CL LSIP200368465) Storage array logs not collected during staged download of firmware via AMW. - LSIP200378291 (CL LSIP200362615) Mel error condition bypass option not implemented for NVSRAM only upgrades via CLI. - LSIP200378303 (CL LSIP200361752) (TD_PT64983) User is able to activate CFW staged files when Reconstruction is occuring - LSIP200413057 (CL LSIP200391258) (1035176) HSW 10.83: Custom Build EMW/AMW right branding bar img - LSIP200415485 (RP LSIP200413052) (TD_PT66612) Script Editor allows creation of more scheduled legacy snapshots than allowed by PFK. - LSIP200433506 Implement support for 240 Drive Capability - LSIP200433540 (CL LSIP200427002) (DF046305) "Disk Pool Auto Conf" dialog update button disabled after adding disks - LSIP200434408 (CL LSIP200430333) (36115,696,760) Unable to upgrade from 07.77.20.00 to 07.86.32.00, consistently fails with "Error 2" - LSIP200435795 Fix LSIP200378297 to include necessary directory. Severity 3 - LSIP200378161 (CL LSIP200365637) (TD_PT65107) Sometimes storage array logging doesNOT collect all files during CFW upgrades. - LSIP200378297 (CL LSIP200364092) Needs attention warning window does not appear when there is RG and bypassable MEL error - LSIP200380358 (CL LSIP200370108) Download NVSRAM help topic should include content for pre upgrade validation and bypass MEL error chk - LSIP200380364 (CL LSIP200370110) Corrections to contents of the help pages for CFW and NVSRAM downloads. - LSIP200380370 (CL LSIP200371372) Update EMW command reference with CLI token added for MEL error check bypass. - LSIP200380386 (CL LSIP200375128) Update OLH page Activating the Controller Firmware and the NVSRAM. - LSIP200396246 Redundancy Check can not be canceled when initiated in the GUI - LSIP200406417 Wembley Power Supply & Fan locations show as Unknown in AMW Severity 4 - LSIP200374569 (CL LSIP200347690) (44449,130,846) Real-Time MB/s Performance Data Graph Not Displaying Data - LSIP200380378 (CL LSIP200374819) Minor update in OLH for the invocation menu for NVSRAM upgrade. Aug 16, 2013 - Version 10.86.xx05.0035 - Fix the following defects Severity 2 - LSIP200419145 SMclient (EMW) failed to launch successfully of HSW 10.86.xx00.0032 on multiple OSes - LSIP200423482 (CL LSIP200417181) SMcli download driveFrimware command returns unknown errors - LSIP200404845 Update JRE to 1.6u43 or later - LSIP200422545 SMdevices/SMagent failed to launch successfully of HSW - LSIP200415010 Add ESM 3.93 for smesm May 8, 2013 - Version 10.86.xx05.0028 - Provide the following new functions (DS3500 and DCS3700) - Software XOR Engine - Workload Capture - View Only Password Management - Fix the following defects Severity 1 - LSIP200362768 ARVM Manual sync and resume operations destroy recovery points without warning Severity 2 - LSIP200362915 OLH:MEL Event Viewer gives 3 severity levels but OLH gives 7 severity levels - LSIP200365370 (TD_PT64972) (RW LSIP200361124) Error creating scheduled snapshot via CLI using parameter "timesPerDay " - LSIP200363351 New files introduced in the Galena SDK are not copied by AIX installer. - LSIP200365690 MEL description showed no information for each of the MEL entries. - LSIP200361124 Error creating scheduled snapshot via CLI using parameter "timesPerDay " - LSIP200359262 (CL LSIP200351851) Discrepancy between DS Storage Manager and Tech Support bundle. - LSIP200358532 Need to update Recovery Guru links in AMW online help - LSIP200358128 After upgrading HSW & CFW, and configuring ASUP, ASUP collection does not take place Severity 3 - LSIP200365628 (CL LSIP200348938) (XB134703) Thin provisioned volume not shown as failed if diskpool is failed - LSIP200364772 (CL LSIP200357900) (TD_PT64883) Unexpected MEL event found: 5223 - Invalid default OS index detected - LSIP200362069 OLH: table listing files in supportBundle lists soc-statistics.csv twice - LSIP200358466 Change "feature key identifier" December 05, 2012 - Version 10.84.x5.30 - Provide the following new functions (DS3500 and DCS3700) - Support for Performance Read Cache - Support for Enhanced Global Mirroring - Async mirroring mechanism - Mirroring over IP - Provide simplified Permium Feature Key structure/activation - High Performance Tier (DS3500 only) - Drive Slot Limit (DS3500 only) - Enhanced FlashCopy - Enhanced Global Mirroring - Enhanced Remote Mirroring - FlashCopy Ligical Drive - Performance Read Cache - Fix the following defects Severity 1 - LSIP200310759 AMW throws java.lang.IllegalArgumentException when opened in Spanish version of Windows - LSIP200326901 (CL LSIP200325737) (c07120999655) Unable to use Recover SMcli command in Script Editor Severity 2 - LSIP200168609 (na) "Test" feature of alerting configuration dialog does not actually test the Event Monitor. Test gives false positive - LSIP200198788 (CL LSIP200165098) HSW 10.77: GUI client unresponsive after closing fw dnld dialog; EMW sa delete - LSIP200274989 Progress indication bar does not report the operation in-progress - LSIP200299703 Snapshot legacy fails with low capacity volumes and default settings - LSIP200300547 The accessibility reader should read the metrics graphs in the performance Modeling/monitoring dialog - LSIP200301303 (RW LSIP200296435) (TD_PT62062) (RW LSIP200291840) Syntax error in script editor and CLI when using "enable storageSubsy - LSIP200306308 Discrepancy in the "Decreasing the Capacity of the Overall Repository " OLH for mirror pair. - LSIP200306526 Incorrect error message during FC ARVM group creation attempt - LSIP200306820 The Event Log doesn't display warning priorities when the view all events filter is selected - LSIP200308123 (RP LSIP200286929) (NA) End iSCSI Sessions button is misleading and iSCSI view needs to be improved - LSIP200308159 Performance Read Cache performance modelling allows the shifting of graph . - LSIP200308162 Performance Read Cache performance modeling graph has discrepancy when the Performance Read Cache is suspended. - LSIP200308164 Complete text is not visible on "change synchronize setting" dialog on linux host - LSIP200308272 Support bundle collected from SDK has no valid information in recoveryProfile.csv and traystateCapturedata files - LSIP200310227 Complete mirror Pair - The selected volume repository selection method is not getting refreshed. - LSIP200310455 Volumes are still T10PI enabled after disabling the option using the automatic configuration on PP - LSIP200311256 Storage Array profile does not show information related to Performance Read Cache Internal volumes. - LSIP200312607 Unable to download firmware to downgrade, unknown error occured during the transfer process - LSIP200313031 (CL LSIP200295919) (1) Pick up the translated properties file from Dell and update the language.jar - LSIP200313450 (CL LSIP200309667) (TD_PT62841) OCR Dual Pwd : java.lang.NullPointerException while activating RVM - LSIP200313532 Pulled Out the SSD drive of the array and "Locate" Option was available for the same SSD drive. - LSIP200313533 Degraded Performance Read Cache - Performance Read Cache which shows small tip window, shows it is failed. - LSIP200314279 Pull in Hitachi RGs into Fremont.1 - LSIP200314500 Pull in latest translation file for OEM dated 7.19.12 - LSIP200314923 Cache in Array - Performance Read Cache attribute is available in restore volume configuration script and throws error while restore - LSIP200315073 Creating ARVM (Enhanced Global Mirroring) secondary drive using wizard fails. - LSIP200315394 (CL LSIP200314073) (1028004) storageArrayConfiguration.cfg shows drive piece order opposite of the actual configuration - LSIP200316417 (TD_PT62780) (RW LSIP200308272) Support bundle collected from SDK has no valid information in recoveryProfile.csv and tr - LSIP200317549 Event log viewer doesn't open - LSIP200317673 7.8x SDK 10.84.G0.01 failed to collect support bundle from 7.7x DS3500/DCS3700 array - LSIP200319102 An error message java.lang.Nullpointer is reported whenever the Recovery Gure is opened - LSIP200320349 (DF495294)event log verification error should advise user to backup and clear event log on optimal array - LSIP200322090 (CL LSIP200265829) (XB101389) Recovery Guru shows BACKUP_DEVICE_INSUFFICIENT_CAPACITY and device - LSIP200322151 Return code: Error 253 - The operation cannot complete because request to quiesce the system failed. - LSIP200322749 (BITS032624) SMcli command to create xml validator file does not pull controller serial numbers from dbm file - LSIP200322752 (CL LSIP200322743) (2003308024) Daily controller reboot due to memory leak in getIscsiSessions_1 - LSIP200322757 (CL LSIP200308207) (XB115456) Add PANIC trap back but avoid fautly conditions - LSIP200322960 (CL LSIP200305465) (TD_PT62669) SMmonitor not start automatically after reboot - LSIP200323143 (ST1028520)HSW 10.83: GUI client no msg dsp when X11 system env dsp setting incorrect - LSIP200323160 (CL LSIP200307396) (2003244488) Insufficient Backup Capacity is reported after upgrading to 7.83.xx.xx - LSIP200323549 (BITS031609)out-of-the-box drive slot limit shown as enabled premium feature in client - LSIP200323586 (BITS030891)Perf mon->historical data->define->view graph, does not open a graph window - LSIP200325581 Legacy collect support data sheduling information does not show in storage array profile - LSIP200327391 Recovery Procedure for ARVM Role Change mentions the wrong sub-menu - LSIP200327507 (CL LSIP200324010) (XB116565) PANIC occurred as result of Child I/O missing from Parent/Child I/O relationship - LSIP200328437 (CL LSIP200326501) (XB125392) SMcli said "syncMirror" option should be used instead of "remoteMirror" option. - LSIP200329416 (CL LSIP200324051) (TD_PT63487) CFW upgrade failed through HSW GUI (PANIC: SOD failure in evf::Volume - LSIP200329920 dbm restore of a simplex array requires editing .xml fil - LSIP200330344 Remote Replication 90 day trial is available on Simplex systems - LSIP200330725 (CL LSIP200319431) (XB121635) ESM upgrade failed and required retry on several ESM's with loss of path redundancy - LSIP200331262 (LSIP200330351) ARVM feature enabled but does not show up as enabled in the featureBundle.txt file - LSIP200331471 Both controllers reboot during DVE - LSIP200331777 Error 9 when automatically assigning hot spare - LSIP200331817 EMW OLH JAR does not contain latest files - LSIP200332629 (RP LSIP200331471) (BITS045773)Both controllers reboot during DVE - LSIP200333336 FREMONT: Disk Pool Automatic Configuration causing Installation Problems - LSIP200333543 (BITS047126)Online Help: Reference Recovery Procedure links are broken - LSIP200334537 (CL LSIP200330745) Prefetch is unselected when write caching is seleted using GUI - LSIP200336421 AMW doesn't warn user about blank password or weak password when trying to save FDE key - LSIP200337805 Manage Premium Features' link on summary tab of AMW is broken on Linux client Severity 3 - LSIP200198787 (CL LSIP200155788) Recovergy Guru displays Failed Logical Drive - Drive Failure when physical drives are opt - LSIP200306387 View Associated Components for Wembley - Show/Hide Drive Type Action Overlaps Associated Drive Icon - LSIP200308643 Empty error message screen when selecting the 'All' tab from the storage subsystem profile screen - LSIP200310974 HSW 10.83: incorrect CLI client output usage "-alertSeverities" - LSIP200310987 MSW does not report correct remaining unsynchronized blocks when Enhanced Global Mirroring AMG is suspended - LSIP200311002 Need better documentation for auto CASD collection when subsystem is added to EMW or SM monitor is started - LSIP200311027 HSW 10.83: EMW OLH cfg auto support bundle incorrect syntax - LSIP200311065 HSW 10.83: EMW OLH show volumes summary incorrect syntax & param - LSIP200311068 HSW 10.83: EMW OLH show volumes reservations incorrect syntax & param - LSIP200311073 HSW 10.83: EMW OLH show volumes performancestats incorrect syntax & param - LSIP200311076 EMW OLH show volumes consumedcapacity incorrect syntax & param - LSIP200311433 (RP LSIP200270528) SNS-Fremont.0:Connection.txt file in support bundle had "NotAvailable Unknown" status - LSIP200312010 (RW LSIP200299385) The Help button in the "Rename Initiator User Label" dialog box does not function - LSIP200313635 SMcli returns "completed successfully" when in fact it was not able to execute - LSIP200313761 (CL LSIP200309176) Reserved drive change results in an increase in capacity + OLH needs an update - LSIP200314974 Fix the SYMsdk build. - LSIP200316757 Reverse reading of axis under performance Monitor Graphical View - LSIP200319355 Fix the Hitachi language.jar - LSIP200319959 MisSpelling of the word "RAID" within the Event Log - LSIP200320550 (DF558820)Automatic Configuration error dialog refers to unsupported RAID level RAID3 - LSIP200322472 MD32xxi/MD36xxi Remote Replication status in array summary is inconsistent with status in Premium Feature menu - LSIP200323460 (1) Change NVSRAM Host Label string translation for LnxTPGSALUA_PM - LSIP200323627 (BITS032068)Volume->Create submenu option is not available - LSIP200324360 Incorrect port number reported in MEL when activating/deactivating Remote Replication(ARVM) - LSIP200325259 (BITS041154)Create SSD Cache option should be greyed out when premium feature is disabled - LSIP200325713 Incorrect number of SFPs reported in AMW - LSIP200326117 During RAID1 Creation Unable to Remove Drives from "Selected List" in "Manual Drive selection" Dialogue Box. - LSIP200327005 Incorrect premium feature limitation reported in AMW - LSIP200328645 (RW LSIP200312010) (RW LSIP200299385) The Help button in the "Rename Initiator User Label" dialog box does not function - LSIP200328996 Mnemonic missing for table in Add Free Capacity (Drives) dialog for a volume group - LSIP200329010 showIscsiStats output in stateCapture does not increment Jumbo Frame Count - LSIP200329309 Assign Hot Spare dialog does not report the correct drawer numbers - LSIP200332745 Fremont Array Profile collected from SYM10.84.G3.16 GUI is incomplete - LSIP200333801 (1) Pick up the hot fix from ML for MainStrings properties file - LSIP200333942 "Repository Candidate" values not updated according to "preferred capacity" during custom creation of TPV - LSIP200336518 Incorrect warning displayed when trying to change/save FDE key with incorrect or no password using SMcli - LSIP200337157 (1) Pick up the latest SMclient files Severity 4 - LSIP200307870 Mismatch of number of volumes used while running Performance Read Cache Performance Modeling - LSIP200308611 Save SAP Dialog References 'System' versus 'Storage Array' - LSIP200309288 (2003283066) SNMP trap does not allow for all 30 chars of device user label - LSIP200312557 Issues in ARVM and SSD cache functional areas - LSIP200316730 (CL LSIP200315853) The buttons "OK ,Cancel and Help" in the firmware activation window are not in their normal position - LSIP200321225 (CL LSIP200320811) (TD_BST1469) Addition of partiallyCompleteVGorDP_ja.html file in language.jar file - LSIP200325082 (CL LSIP200315850) The NVSRAM field does not get populated under firmware activation window in staged download. - LSIP200325253 Modify the Event log verification error when performing an EMW based CFW download - LSIP200327504 (CL LSIP200293205) cleanup ion showable objects - LSIP200336036 Error message displayed when the wrong security key is validated does not match error message in online help October 24, 2012 - Storage Manager Installer package version 10.83.45.23 - Provide the following new functions - Support for Windows Server 2012 - Fix the following defects - LSIP200315853 The buttons "OK ,Cancel and Help" in the firmware activation window are not in their normal position. - LSIP200316250 Description of the parameter "reservedDriveCount" is incomplete in EMW Help window 10.83.xX.21. - LSIP200320811 Addition of partiallyCompleteVGorDP_ja.html file in language.jar file. - LSIP200309176 Reserved drive change results in an increase in capacity + OLH needs an update. - LSIP200313353 (RP LSIP200309176) Reserved drive change results in an increase in capacity + OLH needs an update. - LSIP200314073 storageArrayConfiguration.cfg shows drive piece order opposite of the actual configuration order. - LSIP200299764 AMW - AMW - Drive Firmware Download window shows package version instead of actual drive FW version. - LSIP200305239 (CL LSIP200304212) Optimize the Repository Utilization related SYMbol commands in translation phase of CSB Collection. - LSIP200307639 (RP LSIP200307349) MEL Event 0x212E has incorrect description in MSW. June 13, 2012 - Storage Manager Installer package version 10.83.35.18 - Provide support for disk pools, thin provisioning and enhanced FlashCopy in DS3500 and DCS3700 storage subsystems with controller firmware version 7.83.xx.xx installed. - Provide support for Asymmetric Logical Unit Access (ALUA) failover method for storage subsystems with controller firmware versions 7.83.xx.xx and higher installed. Currently, this failover method is supported for Microsoft Windows 2003 or 2008 operating system (OS) environments when a Windows ALUA host type, W2KALUA, is selected for the defined host and an ALUA-supported MPIO/DSM driver version 01.03.0305.0608 or later is installed in the host. - Provide new look and feel of the Storage Manager Subsystem Management window that is more intuitive. - Remove the IBM Support Monitor Profiler functionality. The storage subsystem Support Bundle (CASD) can be saved automatically using the new Support Bundle collection scheduler functionality in the IBM Storage Manager enterprise management window. - Provide support for the creation of T10 PI-enable arrays and logical drives using 3TB NL FC-SAS drives in DS5020, DS3950, DS5100 and DS5300 storage subsystems with controller firmware version 7.83.xx.xx installed. - Increase drive firmware timeout setting to allow simultaneously updating ATA translator firmware on up to five 3 TB SATA drives having an "Incompatible" in EXP5060 enclosure. - Fix the security vulnerability in IBM Support Monitor Profiler code by removing the Support Monitor Profiler code. The same capability is provided by the automatically CASD collection feature in the enterprise management window. - Provide the following defect fixes. - LSIP200228940 Wrong OID being sent in SM SNMP traps - LSIP200188599 6.60.22.00 to 7.60.28.00 upgrade process not checking for 40MB dacStore causing lockdown - LSIP200144849 Solaris (SPARC) SM 10.70.G5.10 cannot manage 06.xx firmware systems - LSIP200152275 Incorrect failing power supply is illuminated to indicate ready for removal on EXP5060 - LSIP200328330 On the window related to the creation of a new Flashcopy schedule, the designation for AM or PM is incorrect in the Japanese version. - LSIP200216342 Degraded Drive Channel (DS3K Recovery Guru showing incorrect recovery steps in CASD support bundle - LSIP200220551 Error emails have international 12h format - LSIP200132007 Cannot select 2 drives for operation of adding free capacity In addition, the IBM DS Storage Manager host software for the servers based on the Intel 64-bit Itanium (IA64) processors will not be provided starting with this version of Storage Manager For more information, please view the IBM System Storage DS Storage Manager Version 10.8 Installation and Host Support Guide and the IBM System Storage DS Storage Manager Version 10 Copy Services User's Guide. December 5, 2011 - Storage Manager Installer package version 10.77.35.28 - Provide support for the new 3TB NL SAS and 3TB SATA drive options. - Fix: LSIP200205484 (CL LSIP200176977) (XB058604) Document the resolution of CR 161638 under the topic Adding Free Capacity to an array in the subsystem management window online help. - Fix LSIP200226406 The "Download Drive and ATA Translator Firmware - Select Devices" window is empty when having "unresponsive" drive in the subsystem. - Fix LSIP200217965 (XB082494) Drive firmware download window does not appear when having "unresponsive" drive in the subsystem. - Fix LSIP200219876 (XB083076) SMcli does not allow update of ATA translator code in drive slots having greater than 2 TB drive installed - Fix LSIP200223993 Able to add a >1TB T10PI drive to an array which is not having >1 TB T10PI drive during logical drive expansion through SMcli interface. Note: T10PI functionality is not curently supported for drives with capacity greater than 1TB. - Fix LSIP200219798 (LSIP200210488) Disable T10PI functionality for drives with capacity greater than 1TB. - Fix LSIP200174227 (CL LSIP200170075) unable to update hard drive firmware in spanish OS/Other OEM. - Fix LSIP200188070 User is unnecessarily warned to contact Support when performing ESM firmware download - LSIP200200128 BladeCenter: SMcli command "show allVolumes summary" return error code 12 - Fix LSIP200202099 Fix incorrect display of the "time Remaining" for the operation in progress - Fix LSIP200193420 Unable to create logical drives on 3TB drives when drive list is specified using SMcli on DCS3700 subsystem - Fix LSIP200193866 Error 570 - The operation cannot be completed due to invalid logical drive protection during FlashCopy creation. The error was caused by the mismatch of the T10PI status between the repository and the base logical drives. The base and the repository logical drives must both have either T10PI enable or disable. - Fix LSIP200159291 (cXB059874) Fix the failure to detect the existence of 40MB meatadata area during the controller firmware version 6.60.x to 7.60.28.x upgrade, causing the subsystem to enter lockdown state. - Fix LSIP200179043 Update of 10.60.xx.xx jar file with the following fixes + LSIP200159439 - (RW LSIP200141758) (CL LSIP200140995) (ST1014144) The default host type reset to index 0 after changing learn cycle + LSIP200173155 - Wrong OS type is displayed change host type dialog + LSIP200174569 - SMcli fails with error 12 when activating remote logical drive mirror + LSIP200133772 - Profile mis-reports EMW version + LSIP200154133 - (CL LSIP200132406) (XB049176) When placing the bottom power supply unit of an EXP5060 enclosure in ready-to-remove state, the service indicator LED was lit for the top power supply unit instead of the service indicator LED of the bottom power supply unit. + LSIP200166766 - RVM popup window hyperlink does not work April 29, 2011 - Storage Manager Installer package version 10.77.35.16 - Provide support for . the new FC-SAS drives with T10PI capability in the DS5020, DS3950, DS5100 and DS5300 storage subsystems. . the new IBM DS storage subsystem DCS3700 controller and drive expansion enclosure. . the DS3524 storage subsystem with DC power supplies. . the new 1TB NL SAS drive options for the DS3500 storage subsystems. . the DS3500 subsystem enhanced capabilities. Please refer to the DS3500 Installation, User's and Maintenance guide or the DS3500 announcement letter for more information. - Change: When opening the Subsystem Management Window user is asked if to set a password. User can select No. If user selects yes, the password can be weak or strong. If no password is set, or a weak password is set, then a message appears recommending a strong password each time the Subsystem Management Window is opened. - Change: Windows MPIO/DSM is now packaged separately. - Fix 135065 (CL LSIP200135059) PRLSIP200076930 : Consistency Group and write-order consistency support for "synchronous" mirroring. - Fix 143785 Script editor set alltrays alarm... task fails to complete. - Fix 144603 Recovery guru displays reconstructed optimal volumes as degraded volumes even after recheck. - Fix 146317 Updating VariationStrings to get back the changes done in LSIP200125405, to have the weak password behaviour. - Fix 145955 (XB053180) DS5020 unable to update CFW to RC_07770500_e10_49xx.dlp. - Fix 135022 Upgrade CFW Window from EMW does not close the password dialog boxes even after Upgrade CFW Win is closed. - Fix 125118 Timestamp within "SDK Translated" support bundle logs (readLinkStatus, socStats, etc) is incorrect. - Fix 136967 SM & XBB2 GURU report "Unknown" for "Component requiring service" after pulling power cable from Drive Tray. - Fix 136996 DFW download window displays optimal for Impending drive Fail. - Fix 137853 SMmonitor does not save ctrl support bundle on critical MEL, but does save ESM state capture. - Fix 139362 save storageArray SASPHYCounts always returns 0 errors for every PHY. - Fix 140818 (LSIP200125405) Revert to original password behavior. - Fix 139616 Entire free capacity of volume group is used when creating 1 TB volume. - Fix 140528 array w/5.42 cfw unable able to upgrade to 6.1x cfw. - Fix 142673 HSW 10.77: Linux SDK - demo_cpp/DQTraceRetrieval program segmentation fault. - Fix 154073 Chessie2 HSW does not display translated RG procedures when CFW is 10T1. - Fix 154228 createRemoteMirror CLI command create synchronous mirror even though writeMode is set to "asynchronous". - Fix 159476 (default host type reset to index 0 after changing learn cycle) (GUI Changes). - Fix 163919 HSW: 10.77.x0.13 Unable to schedule a snapshot recreate with (US & Canada) time zones and other ones as well. - Fix 143181 Online help for reset storageArray SASPHYBaseline is for all devices, does not match CFW design SMclient. - Fix 143670 Selection for increase in volume size during DVE does not correctly respond to the inputs selected by user. - Fix 144478 Start Controller Trace content missing min. firmware level. - Fix 144484 OLH enable sa remote status notification missing min cfw level SMclient. - Fix 135916 Volume Initialization Progress Bar widens and then slims repeatedly when Modification Priority is changed on XBB2. - Fix 140667 PB1-3 arrays w/cfw 6.7x ctrl clock sync dialog cropped. - Fix 141650 Extra Tab added to each "Drive Channel #" in the details section in the XBB2 & SM storage array profile. - Fix 138596 Word mismatch found on Agent description during HSW installation for rpm description. - Fix 145027 Drive Selection dialog is misleading, regarding operation duration. - Fix 145028 Duplicate message found in Confirm...Drive Selection dialogs. - Fix 145809 Graph number drop down menu incorrectly labeled after adding and removing defined graph. - Fix 143726 Column Formatting Under "Associated Volumes and Free Capacity" in Array Profile Not Properly Aligned. - Fix 143728 Column Formatting Under "Associated Drives" In Array Profile Not Properly Aligned. - Fix 143770 WSAS RBOD enclosures are not reported as Controller/Drive Expansion Enclosures in array profile. - Fix 155641 Minimum FW version showed incorrect value (5.40.00.00) in FWupgrade window. February 22, 2011 - Storage Manager Installer package version 10.75.35.08 - Fix 187289 Incorrect recovery guru replacement for "Host Switch Card Problem". - Fix 187307 Unable to secure erase unassigned secure-enabled drive. - Fix 187701 Binary file does not report the correct message using SMcli after error injection. - Fix 186969 (ST1012090) HSW 10.75: CLI manpage CMD LINE PARMS section -S des s. - Fix 187105 (201267) (CL #WIC~182282) 201267) Battery reporting End of life. - Fix 186463 HSW Recovery Guru Misreporting failed power supply location. - Fix 186808 (CL #WIC~186498) (CL #WIC~186058) (ST1011637) HSW 10.75: array w/5.42 cfw unable able to upgrade to 6.1x cfw. - Fix 186818 (CL #WIC~181558) (CLI manpage SYNOPSIS & CMD LINE PARM dsp "-r". - Fix 186821 (CL #WIC~182174) CLI manpage CMD LINE PARMS sec -I desc missing statement for -q parm. - Fix 186824 (CL #WIC~182171) CLI manpage CMD LINE PARMS section -v desc missing newlines. - Fix 186825 (CL #WIC~182172) CLI manpage CMD LINE PARMS sec -w desc missing example cfg output. - Fix 186863 (HSW 10.75: AMW Configuration Database Diagnostic dialog isn't wide enough-Linux. - Fix 185807 AMW OLH files have been checked in. Pick them up. - Fix 184796 (CL #WIC~184785) Correct steps in the failedPowerSupply.html. - Fix 187289 (XB040741) Recovery guru fix to not identify the controller as the replacement Instead of HIC. November 19, 2010 - Storage Manager Installer package version 10.70.35.25 - Fix 173657 EMW reports array is optimal while AMW reports volumes not on preferred path. - Fix 180560 No Online help for Remote Status Notification. - Fix 181374 SMclient 10.70.G3.12 - network error when trying to add arrays. - Fix 181418 HSW 10.70: EMW OLH delete volume topic command syntax section is incorrect. - Fix 181440 HSW 10.70: EMW OLH Create RAID Volume (Free Ext..) topic dsp create hostPort Id. - Fix 181441 HSW 10.70: EMW OLH Set Enclosure SAA Indicator topic dsp incorrect SMcli usage. - Fix 181247 PR LSIP200076930 : Consistency Group and write-order consistency support for "synchronous" mirroring. - Fix 182486 (RP #WIC~181247) PR LSIP200076930 : Consistency Group and write-order consistency support for "synchronous" mirroring. - Fix 182871 (CL #WIC~182218) Disable check for "Weak password" (PR LSIP200011112) for DR builds. - Fix 181501 Start Cache Bkup Dev Diag topic diagnosticType desc extra sp. - Fix 181759 EMW OLH iSCSI Tgt Properties topic missing. - Fix 181558 CLI manpage SYNOPSIS & CMD LINE PARM dsp "-r". - Fix 181559 CLI manpage SYNOPSIS & CMD LINE PARM missing [-quick]. - Fix 182167 SMcli manpage CMD LINE PARAMS sec "DNS/Name " incomplete string. - Fix 182168 CLI manpage CMD LINE PARMS section -d desc missing newline. - Fix 182170 CLI manpage CMD LINE PARMS section -i desc missing newline. - Fix 182171 CLI manpage CMD LINE PARMS section -v desc missing newlines. - Fix 182172 CLI manpage CMD LINE PARMS sec -w desc missing example cfg output. - Fix 182173 CLI manpage CMD LINE PARMS sec -I desc missing multiple newlines. - Fix 182174 CLI manpage CMD LINE PARMS sec -I desc missing statement for -q parm. - Fix 182175 CLI manpage CMD LINE PARMS sec -I desc missing info type descriptions. - Fix 182176 CLI manpg CMD LINE PARMS sec -S desc missing list of suppressed msgs. - Fix 182550 (CL #WIC~172368) Host properties has an unresolved asterisk. - Fix 183288 (CL #WIC~171194) Change Preferred Loop ID window does not display eight ports by default. - Fix 183908 Duplicate host port identifier dialog, in the second sentence "please" - 'p' is not Uppercase. - Fix 184033 (CL #WIC~182520) Symplicity 10.70.G3.12 Incorrectly Reports Disk Utilization for T-3 Array. - Fix 184243 (cXB042763) SMcli accepting weak password on first try but failing on subsequent attempts. - Fix 180671 HSW 10.70: CLI manpage output missing content for remoteStatusNotification. - Fix 169354 (cXB044330) - Port info missing in drive channel section - Fix 176937 (cXB029096) Discrepancy in online help performing DVE on Basic Windows Disks. - Fix 179887 (cXB038459) AIX HACMP process killed by SMagent startup process. - Fix 184250 (cXB042394) Online help incorrectly says cache is disabled during learn cycle. - Fix 184500 (XB042375) Update online help to inform restriction using 2nd ethernet port. Fixes in MPIO win 01.03.0305.0409 - Fix 172576 During failover driver installation security alert message doesn't show the module type for all module types. - Fix 173688 Virtual Disks not on preferred path when placing controller back online after 5 minute wait. - Fix 174692 unexpected failover running W2K08 R2 with QLogic fibre in sanboot environment - Fix 175707 invalid device paths when running exceptions with the selective lun transfer option. - Fix 175709 windows text changes to go along with CR175707 - Fix 175848 Persistent LPW settings invalid . - Fix 176141 Remove adapter reset during DSM install. - Fix 176347 (RP #WIC~176346) Failover requests may not be retried when 91/36 condition is returned. - Fix 177108 TASK ATTRIBUTE SETTING SET TO 'UNTAGGED' eventually VNOPP. - Fix 181493 allow install process to select the correct IO Timeout values for the DSM based of the version of OS. - Fix 182112 Minor Common code changes for addition of Virtual Lun scan delay in Linux. - Fix 182904 dsmUtil -P option not working on 32 bit versions of the OS. - Fix 183250 dsmutil -w causes access violation. July 13, 2010 - Storage Manager Installer package version 10.70.35.10 - Fix 179231 CL #WIC~176729) New Drive Not Available from "Replace Drives" Screen. - Fix 179395 null pointer exception when closing AMW. - Fix 179620 (CL #WIC~176383) HSW 10.60: Linux GUI client background color render issues w/EMW and w/AMW. - Fix 178291 (CL #WIC~178115) (cXB033757) unable to activate Remote Logical Drive Mirroring. - Fix 178463 When using Recovery Tool scripts, EMW doesn't bring up password box and hangs script execution. - Fix 177943 (CXB033285) mismatch between online help and script editor. - Fix 176835 HSW 10.70: Custom build arrays w/cfw 6.17 non-embedded dialogs dsp LSI logo. - Fix 176997 Move Host Out of Host Group Option enabled when no Host Groups are defined. - Fix 177004 Checking translated Client Strings and RG pages. - Fix 176844 Unable to resize the Add Free Capacity pop up window enough to see the whole page. - Fix 175855 Does not support legacy Windows host types. - Fix 176133 If an exception is returned from CFW during Volume Group Import, it tries again when the window is closed. - Fix 176500 Drive status Icons are not correct in Properties window of Physical tab. - Fix 176544 EMRSRuntimeConfig.xml file is updated when cancel is clicked on RemoteStatusNotificationDialog. - Fix 173326 (CXB028620) initial AMW password screen has misleading entry. - Fix 176034 Two RG's exist for security key lock condition. - Fix 171809 Update affected RG procs for a corner case of component invalid for enclosure. - Fix 174107 (XB027592) SANtricity ES displayed instead of Storage Manager in the Host SW GUI. - Fix 171715 (cXB021495) Incorrect text when configuring array. - Fix 154327 (cXB008466) recover logicalDrive drives command does not allow the dssPreAllocate parameter. - Fix 167607 (cXB017778) German Language: IBM DS Storage Manager 10.60.x5.11 install failed. - Fix 169946 (cXB019574) Delay in SMdevices when USB floppy drive used with no disk. - Fix 167297 (cXB017585) CLI "Set Enclosure Service Action Allowed Indicator" fail by syntax error. - Fix 166235 (cXB029825) Duplicate alert mail received when one critical event occurred. - Fix 177027 (XB036727) .csv file not showing sfp statistics. - Fix 166578 (XB019139) Remote Login Settings can not be changed through the GUI. - Fix 172506 (cXB027167) "drives" improperly customized to "diskDrives". Fixes in MPIO win 01.03.0305.0321 - Fix 175630 "Round Robin with Subset" MPIO policy is available in W2K8_64_R2 device. - Fix 176346 Failover requests may not be retried when 91/36 condition is returned. - Fix 175707 invalid device paths when running exceptions with the selective lun transfer option. - Fix 175848 Persistent LPW settings invalid. - Fix 174692 unexpected failover running W2K08 R2 with QLogic fibre in sanboot environment. - Fix 173730 possible dead lock condition when luns are being discovered. - Fix 169467 Blue Screen of death during I/O and sysReboot. - Fix 169555 Persistent Reservation failed with one broken path. - Fix 169330 always set 'Force Quiescence' on failover, not on rebalance (common code). - Fix 169331 always set 'Force Quiescence' on failover, not on rebalance (windows specific). - Fix 169462 MPIO Device Specific Module (DSM) update failed while installaing HSW on W2k3-IA64. - Fix 168576 allow force transfer option when using the selective lun transfer mode (common code). - Fix 168577 allow force transfer option when using the selective lun transfer mode (windows specific). - Fix 168695 Path state change during PathVerify() caused I/O failure. - Fix 168702 DSM I/O recovery changes for service mode while running lower timeout settings. - Fix 166469 (CL #WIC~165214) Controller A Permanently Held In Reset By Controller B After First SysReboot. - Fix 166886 W2k3 IA64 crashes when running dsmUtil -S with iSCSI Snowmass array. - Fix 165437 common code changes for Selective Lun Transfer mods dealing with controllers held in reset. - Fix 165438 windows specific code changes for Selective Lun Transfer mods dealing with controllers held in reset. - Fix 165122 I/O fails on one iSCSI I/O port. - Fix 165410 pathStateIndex is not initialzed for all paths inside mpp_AreAllPathsFailed. - Fix 163872 I/O errors occur before PDORemovePeriod expires when paths offline. - Fix 160892 I/O errors after 2sec power cycle with reduced failover times on Win2k8. - Fix 155388 (LSIP200000167) Eliminate Rebalance Settings - MPIO. - Fix 161407 Text string in dsmUtil has an incorrect length. - Fix 161491 Seeing host hang due to mppdsm during sysreboot-host root booted. - Fix 158047 Minor DSM changes to support MPIO queueing of some non-Read/Write requests. - Fix 158044 Unable to use dsmUtil options when multiple DSM's are installed on Server 2008 'R2' setups. - Fix 155020 MPIO non-RW commands may be blocked from being issued to the physical device. - Fix 155021 Synchronous I/Os returning reservation conflict are not being decoded correctly. - Fix 155308 not all exception time stamps were being initialized at IO entry point. - Fix 155313 PR registration might not happen on all paths before I/Os are being issued to the phys device. - Fix 155944 dsmUtil doesn't work under Server 2008 'R2' environments with no device attached. - Fix 155974 Bugcheck error DRIVER_PAGE_FAULT_IN_FREED_SPECIAL_POOL (d5). - Fix 154721 W2K3_x64 host sees two paths (preferred alternate) from Matterhorn. - Fix 173688 Virtual Disks not on preferred path when placing controller back online after 5 minute wait. - Fix 171742 Invalid NT Status passed from SRB Device Control to InterpretErrorEx(). - Fix 169500 Modify some errorlog messages to add details in raw event data. - Fix 167354 device node for UTM root bus remains in the device manager even after uninstalling the driver package. - Fix 166143 incorrect variable initialization causes a compiler error. - Fix 164432 blue screen when plug and play test in WLK 1.4 is executed against UTM driver. - Fix 164379 BSOD when running Veritas Volume Manager. - Fix 159659 Minor common code changes to support Windows MPIO change for lower HBA timeouts. - Fix 153136 Blue screen on Windows max volume. - Fix 153599 'dsmUtil' usage shows '-r' as a valid option when it is not. - Fix 175338 (XB030285) Windows 2008 R2 SAN boot failure. - Fix CR 169284 : Wrong OID being sent in SM snmp traps 10.50.x5.23 November 10, 2009 - Storage Manager Installer package version 10.60.35.17 - Fix 154664 cXB005198 Mismatch online actual functionalitySmart BBU learning cycle - Fix 161844 (cXB012998) Unable to collect all support data from client by only specifying a file name with no path. - Fix 159857 Dynamic Segment Size (DSS) PreAllocation Occurs for High Level Volumes - Fix 165521 (RW #164033) (CXB014946) Drive attach premium feature did not list the number of drives enable - Fix 165954 Save configuration does not generate valid code - Fix 163439 When changing host type, IBMi shows up in the list, but in the default mapping drop-down it doesn't - Fix 164033 (XB014946) Drive attach premium feature did not list the number of drives enable - Fix 163447 (XB014535) Incorrect syntax in SM to fail diskDrive - add Support for esm fw 9919 - Add support for the new DS3950 Storage Controller Subsystem model 1814-94H and 1814-98H, which supports the attachment of the new EXP395 Storage Expansion Enclosure Subsystem model 1814-92H. - Add support for 4 Gbps Fibre Channel 600 GB/15K DDM feature and the Encryptible 4 Gbps FC 600 GB/15K DDM feature. - Add support for DS5300/DS5100 attachment to the EXP5060 High Density SATA Drive Enclosure - Initial release of IBM DS Storage Manager Profiler for automatically collecting/managing the Storage Subsystem support data (CASD) at predefined (user changeable) schedules. September 14, 2009 - Storage Manager Installer package version 10.60.35.11 - Fix CR163901 (XB014846) DS Mgr locked up when setting IP addresses for the iSCSI host ports. - Fix CR164182 (XB014594) Missing subsystem name when asking for password in EMW firmware upgrade. - Fix CR164003 (XB014895) iSCSI - ERROR 2 message did not state DHCP server or network is the cause of problem. - Fix CR163243 (XB014345 ) Unable to open iSCSI host port configuration window in Storage Manager. - Fix CR163465 (XB014295) Cannot configure iSCSI through GUI due to Error 3 - The operation cannot complete. - Fix CR163388 Need 10.35.xx.xx level ESM code added to Allegheny HSW SAN ES. - Fix CR164405 HTML tags are left in the "Enter Password" dialog when opening the AMW with a password set. Fixes in MPIO win 01.03.0305.0216 - Fix CR163672 (XB014732) Timing issue where a path may not be properly registered for a lun when discovered. July 27, 2009 - Storage Manager Installer package version 10.60.35.05 - Fix 154664 (XB005198) Mismatch online help for Smart BBU learning cycle. - Fix 159857 (XB010373) Dynamic Segment Size (DSS) PreAllocation Occurs for High Level Volumes. - Fix 152581 (XB003579) New MEL Events 5801 and 5802. - Fix 161510 EMW shows array unresponsive while AMW responds, when SMagent killed for in-band and out-of-band connection - Fix 161754 About dialogs for AMW and EMW (Allegheny build) showing incorrect date. - Fix 161489 FAQ links missing from Create a Snapshot Volume Wizard - Create Volume. - Fix 161578 (XB013009 ) SAA and fault LED were not lit when BBU in Battery Replacement. - Fix 160978 CLI Command "set tray alarm" never completes. - Fix 160929 Drawer # not displayed for empty slot in AMW Physical Tab. - Fix 145989 (c436574) Java CoreDump on QS22 blades. Fixes in MPIO Win 01.03.0305.0212 - Fix 155974 Bugcheck error DRIVER_PAGE_FAULT_IN_FREED_SPECIAL_POOL. - Fix 155944 dsmUtil doesn't work under Server 2008 'R2' environments with no devices attached. - Fix 153599 'dsmUtil' usage shows '-r' as a valid option when it is not. - Fix 153128 (RP #WIC~153121) Path Loss Recovery fails when Port Down Retry Count set below recommended value. - Fix 153121 Path Loss Recovery fails when Port Down Retry Count set below recommended value. - Fix 152279 InterfaceType definition needs to be defined at controller path level for Windows. - Fix 152208 DSM method 'mppWin_RetryRequestCallback' may use an invalid SRB pointer. - Fix 151457 (RP #WIC~151232) (CXB005577SCSICompliance failure when using Emulex PCi-e Hbas151224. - Fix 151224 (RP #WIC~151178) System BSOD during a fault injection cable. - Fix 151211 (RP #WIC~151204) Extended Path Recovery support needed for any DisableLunRebalance setting. - Fix 151204 Extended Path Recovery support needed for any DisableLunRebalance setting. - Fix 150892 Minor change to support Server 2008 'R2'. - Fix 150473 Path loss recovery should not run when array in AVT mode. - Fix 150232 clone of CR150231 for allegheny trunk - windows string API being used at raised IRQL. - Fix 149952 Windows stop error 0x8E in mppdsm.sys upon executing cacheslam. July 01, 2009 - Storage Manager Installer package version 10.50.35.23 - Fix 157229 (TD_PT36275) Able to change array lock key during drive reconstruction on DS5000. - Fix 157411 (TD_PT36343) the dialog to add/change the Array PW before unlocking FDE Drives is not generated from "drive". - Fix 157420 (TD_PT36350) FDE Security key overwritten during key change operation. - Fix 157424 (TD_PT36354) there is no table showing the locations of drives upon completion of an export VG operation. - Fix 152367 SRA testFailover/failover fails when password is set on array. - Fix 157915 Unable to remove Unidentified Storage Array from EMW. - Fix 158505 (CL #WIC~157552) During MPP install on SLES 11, script SMmonitor is broken. - Fix 158177 No event action occurs after selecting optimal array status link. No MPIO fixes this release. April 22, 2009 - Storage Manager Installer package version 10.50.35.19 - Fix 143520 (420734f_1) CASD svlShow command usage incorrect. - Fix 150646 (XB004966) SOC data not in Collect All Support Data. - Fix 155784 (CL #WIC~150646) (cXB004966) socStatistics.csv file not collected in Emerald CASD. - Fix 155343 (CXB009469) "Working" does not stop in SMIA 10.50.35.14. - Fix 155009 HSW 10.50: CLI client output displays two entries per discovered array. - Fix 154652 (CL #WIC~154005) (XB007458) SMCli fails to create Host and Host Ports. - Fix 154179 (RW #152324) Upgrade Checks fail to perform if non-responsive system is in device view. - Fix 154168 (C463376) DTL-Ghost LUNs and hot-spares after head-swap migration. - Fix 153860 (RW #153004) (C460344) DTL-incorrectly IBMized SMCli VolumeCopy cmds. - Fix 153462 (CXB007378) Unstable SM 10.50.G5.05 - won't manage back past 5.40. - Fix 153174 (CL #WIC~152494) SMclient AMW doesn't reflect changes of the storage array during IO. - Fix 152540 (CL #WIC~150215) Create IB or FC host port through script engine never succeeds. - Fix 152384 (C459598) Aurora FW Upgrade Utility DDE errors after upgrade. - Fix 152324 Upgrade Checks fail to perform if non-responsive system is in device vi - Fix 151413 (CL #WIC~147254) (CR6726565_0 ) GUI should not display mulitple Ethernet speed options. - Fix 151406 (CL #WIC~150491) HSW Trace Facility Does Not Work From AMW With older Releases. - Fix 151271 EMW windows disappears when the Manage array link under the setup tab is clicked. - Fix 150878 Jar Not Displaying Correctly - No Link for Initial Setup Tasks. - Fix 150549 unable to click on any buttons or close the "Storage Subsystem Added" prompt - Fix 150047 Resume RVM synchronization is working immediately and failing to update RemoteMirrorStatus. - Fix 149869 (CL #WIC~149086) (c446470) Wrong OID being sent in SM snmp traps. - Fix 149797 (c448779) (CL #WIC~147071) Linux with Japanese language sends garbled characters in email alerts with default. - Fix 150096 (c435908) MEL logs controller cache not enabled or internally disabled. - Fix 148222 (c416955) Driveside number of controller B wrong in profile. - Fix 148002 Menu Bars not behaving properly on SAN ES AMW. - Fix 147178 (c445211) Power Supply reported as missing/removed in GURU. Fixes in MPIO 01.03.0305.0110 - Fix 151247 (TD_IOP1759) Cluster reservation loss during switch port fail test. - Fix 151232 (CXB005577) SCSICompliance failure when using Emulex PCi-e Hbas. - Fix 151222 (RP #WIC~151178) System BSOD during a fault injection cable pull. test on a single port controller. - Fix 150231 use of windows unicodeToAnsii string APIs at elevated IRQL can cause BSOD. - Fix 150204 (RP #WIC~149952) CacheSlam/Smash5 - windows stop error 0x8E in mppdsm.sys upon executing cacheslam. - Fix 149197 returned sense information is incorrect when IO is issued through IOControl path. - Fix 147977 (RW #WIC~147883) DSM does not register Persistent Reservation for new paths. - Fix 147960 (TD_PT32185) Cluster setup fails on secondary node due to PROut Clear receiving Check Condition. - Fix 147668 (RP #WIC~146902) I/O not retried with SRB_STATUS_ERROR. - Fix 147311 (TD_PT31831) Install of multipath driver causes STOP 0x7E in mppdsm.sys. - Fix 146000 Window Server 2008 dsmUtil app crash issue with dsmUtil.exe-a -S. - Fix 145513 "SaveSettings" option for per-protocol timeouts. - Fix 143957 (CL #WIC~143612) windows sysdep changes for linuxrdac does not recover correctly when HBA chip faults. - Fix 143866 (RP #WIC~141030) (TD_PT29856) IO read error detected on win2k3 host during sysReboot stress w/ cache mirroring enabled. - Fix 143803 Bug in mpp_FailPath causing failover not to happen. March 18, 2009 - Storage Manager Installer package version 10.36.35.13 - Updated jar files 6.60.22.xx support. -Fix 152541 (CL #WIC~150215) Create IB or FC host port through script engine never succeeds. -Fix 154005 (XB007458) SMCli fails to create Host and Host Ports. Upgrade Utility - version 10.36.x5.10 - Removed all firmware files. Users can download the latest firmware levels at: http://www-1.ibm.com/servers/storage/support/disk/ December 20, 2008 - Storage Manager Installer package version 10.36.35.07 - IBM DS4000 Storage Manager Controller Firmware Upgrade Tool has been updated to v10.36.x5.08. Includes Controller Firmware v07.36.12.00 with the following fixes. - Fix CR146467/CR144696 PANIC: DBM block set mismatch while rebooting the controllers. Causing the controllers to go into a continuous reboot cycle. - Fix CR151507/CR150024 Create new shell command to set the WWN on a volume. - Fix CR149810/CR148444 IO error: (** Bad address **, Cannot close target) on Solaris host during concurrent code down load. - Fix CR149787/CR149467 Ancient IO during concurrent code down load. - Fix CR149565/CR149299 PANIC: Invalid memory block at 0x58d2628 while collecting Support Data. - Fix CR149470 Ancient IO scsiCmd 55. - Fix CR149441/CR149290/CR140998/c421316 Panic/Reboot loops with very large RAID-1 at vdmRAIDImplExcl. - Fix CR149335 DS4800 controller hit panic while sysReboot stress is running and drives are reconstructing. - Fix CR149319/CR149006/c423053 Critical event type 281B & #147;Nominal temperature exceeded”. - Fix CR149247 Unexpected Failed Power Supply Canister. - Fix CR149137/CR148640/cXB003540 RVM deletion operation staying queued and causing loss-of management. - Fix CR148775/CR147868/c443192 Old host information not cleaned up when PLOGI processed. - Fix CR148785/CR148480 Foreign unassigned Rev 4 DACStore remapped but not peered. - Fix CR148698/CR148686 Scan volume with repair on degraded RAID6 volume hangs. - Fix CR148637/CR147116 Watchdog TO while running power cycle test. - Fix CR148472 Inserting up-rev foreign controller causes DacStore layout to change. - Fix CR148281/CR141712 NS7 does not negotiation host link speed correctly. - Fix CR148768/CR148697 Assertion failed: ssid ; INVALID_LUN, file eelHost.h, line 406 during VG defrag and STIO November 19, 2008 - Storage Manager Installer package version 10.36.35.07 - Added support for DS3000 controller firmware release 07.35.41.00 - Fix XB004177 - CR149660 (CL #WIC~149623)9663 ESM firmware file does not exist in the Storage Manager ESM directory October 20, 2008 - Storage Manager Installer package version 10.36.35.05 - Fix 435051 - CR144592 Failed drive posts in MEL as info only. - Fix 432205 - CR144161 When performing increase capacity, Total Array size is reduced. - Fix 419888 - CR142226 Replacing a failed hotspare is not clearing up the HS list. - Fix 409823 - CR140159 IBM prod name became engenio's name using 6.10.06.xx firmware. - Fix 148110 SM profile view (controller tab) has no deliniation between cache backup devices. - Fix 148183(TD_PT32264) GURU displays Unknown Failure Type after replacing failed drive with foreign drive of smaller size. - Fix 148441 (CL #WIC~144294) Duplicate Mnemonic on the Hot Spare Drive Options dialog. - Fix 148462 Need to include the latest versions of sam960.jar and sam960.files.jar . - Fix 148497 Need to include the latest versions of sam960.jar and sam960.files.jar. - Fix 144863 (CL #WIC~144650) The icon in the recovery guru summary panel is missing for Missing Hot Spare Drive. - Fix 143535 Recovery Guru does not give instruction about the Replace Drive Feature for a failed drive. - Fix 145467 Select Storage Array (Create Remote Volume Mirror)dialog is missing a text label. - Fix 146154 (TD_PT31390) Customer support bundle feature file not saved in the specified location. - Fix 146168 (CL #WIC~146146) Remove the limit of 10MB Volume size from HSW. - Fix 146574 (CL #WIC~145779) (TD_PT31262) drive channel diagnostics do not complete. - Fix 147955 (CL #WIC~141582) (RW #120306) (CL #WIC~112864) Usability Issue with Misleading RVM Status Message. - Fix 144114 (RP #WIC~143742) (c419888) Unable to de-assign a missing Hot Spare drive. Fixes in MPIO 01.03.0305.0016 - Fix 147883 DSM does not register Persistent Reservation for new paths. - Fix 148057 (RW #WIC~147960) (TD_PT32185) Cluster setup fails on secondary node due to PROut Clear receiving Check Condition. - Fix 146902 I/O not retried with SRB_STATUS_ERROR. - Fix 146542 Modify toolsign.bat to timestamp the driver binaries during Release signing. - Fix 146792 DSM does not register Persistent Reservation for new paths. August 09, 2008 - Storage Manager Installer package version 10.30.35.09 - Support for the new DS5300 Storage Controller Subsystem model 1818-53A, which supports the attachment of the new EXP5000 Storage Expansion Enclosure Subsystem model 1818-D1A. - Support for the new DS5100 Storage Controller Subsystem model 1818-51A, which supports the attachment of the new EXP5000 Storage Expansion Enclosure Subsystem model 1818-D1A. - IBM DS4000 Controller Firmware Upgrade Tool updated to v10.15.x5.02. Includes Controller Firmware v07.15.07.00 with new MEL Health Checks for the Upgrade Utility. - Incorporate the following field defect fixes - Fix 429329 - CR 144275 Can't parse show LogicalDrives in SM CLI. Changes output label "Logical Drive world-wide identifier" back to "Logical Drive ID" as displayed in previous versions of Storage Manager. - Fix 419888 - CR143742 Replacing a failed hotspare is not clearing up the HS list - Fix 409450 - CR141127 Error installing RDAC-MPIO - storport.sys is not valid - Fix 394788 - CR 136551?Battery reported as failed but PSU is the problem. - Fix 411250 - CR 132888 Arrays Not in Profile When Bypassed Drive in System - Fix 429329 - CR144275 SMCLI - showlogicaldrives command gives incorrect output. - Fix 423901 - CR140655 Date of manufacture for drives missing in Profile. - Fix 434616 - CR143724 AIX DS4000 SMagent is trying to use DS3000 java and fails to start. Inband management affected. May 13, 2008 - Storage Manager Installer package version 10.15.35.08 - Support IPv6 on the Ethernet management ports for DS4800, DS4700, and DS4200. - Increase the number of supported host logins on the DS4700 and DS4200 controller to 640 from 512. - Update Microsoft VDS/VSS providers (Windows 2000, 2003, & 2008) - Update SMI-S provider. - Windows Server 2008 support. - IBM SDD support on Windows and HP-UX - Incorporate the following field defect fixes - Fix 414217 - CR137913; Maxtor Drive Can Not Be Replaced By Seagate Drive. - Fix 409625 Replace Drive Doesn't Allow Choosing 10033RPM HDD for 10000RPM HDD. Description: Only drives of the same spindle speed are allowed to become candidates in the drive integration window to replace a failed drive. One of the drive vendors reports their drive as 10033 (Seagate) vs. 10000 (Hitachi and others). The Host Software will not display the Seagate drive as being a drive replacement candidate. - Fix 408964 - CR 136346; SAN Boot Failover Failure with 4 FC PATHs with MPIO. Description: SAN Boot configuration with four I/O paths from Host to DS4800. Host Software SM9.60.xx.03 with MPIO failover. Failover test resulted in MPIO and DS warnings/errors in the Windows event logs, servers unresponsive, blue screens etc. - Fix 394788 - CR 136551; Battery reported as failed but Power Supply Unit is the problem Description: Recovery Guru procedure is incorrect. Recovery Guru points to the wrong online recovery instructions for the problem. - Fix 416605 - CR140051 Missing Installer Properties file in SM 10.10 Description: Package missing a file needed for unattended installation. Feb 26, 2008 - Storage Manager Installer package version 10.10.35.06 - IBM DS4000 Controller Firmware Upgrade Tool updated to v10.10.x5.09. Includes Controller Firmware v07.10.23.00 with the following fix. - Fix 137352; DS4000 Storage Controllers upgraded to firmware v07.10.22.00 incorrectly calculates the free capacity of arrays. Array configuration activities (e.g. LUN expansion, create new LUNs, etc...) may lose access to the storage logical configuration. - IBM DS4000 Storage Manager Client updated to v10.10.xx.06. - Added Storage Manager Client support for DS4000 Controller Firmware v6.15.xx.xx. - Storage Manager Client GUI fixes for DS3000 Storage Subsystems Management. - Incorporate the following Storage Manager Client fixes to support DS4000 Controller firmware v6.60.xx.xx. - Fix 132438 Getting caught in loop when trying to create hot spare. Description:: IBM DS4000 Storage Manager Client getting into an infinite loop of window closing events when creating a hot spare. - Fix 125160 (PMR35194,015,866) Unable to received email alerts. Description: IBM DS4000 Storage Manager is not compliant with RFC 821 or 2821 because the QUIT command was sent without waiting for response after "end of data". - Fix 131823 Help search for keyword "Risk of Application Errors" has an Invalid character. Description: Opened help and searched for Keyword " Risk of Application Errors". Most of the pages which have Risk of Application Errors as keyword have an invalid character next to it. - Fix 133323 (c388614) RVM re-activation fails if full capacity is used. Description: Storage Manager needs to compare the raw capacity rather than the usable capacity when creating regular volumes. - Fix 131348 ReRead during Verify of media scan. Description: The following fix is required to support the ReRead operation during the verify of a media scan. - Fix 136131 Need to add ESM Firmware v9673 and v98B3 to Storage Manager SMclient. Description: Include new versions of ESM firmware files in appropriate Host Software directories to support ESM Firmware auto-code sync. Jan 23, 2008 - Storage Manager Installer package version 10.10.35.04 - Support for DS4000 Controller firmware 7.10.xx.xx. - RAID 6 is available on DS4200 and DS4700 Storage Subsystems. RAID 6 is not supported on DS4800. - Support for greater than 2TB Logical Drive. - Support for RAID 0 and 1 arrays with more than 30 drives. - Increase maximum number of partitions. DS4200 and DS4700 will support 512 and DS4800 will support 2048. - Enhanced Cache support. - HP-UX v11.23 IA64 full solution. Provide a full solution (all client software) for 64-bit HP-UX v11.23 (Itanium2 processor). Previous support is I/O attach only and requires a separate management station running a client supported operating system. - Increased Queue depth. Increase the DS4800 controller queue depth to 4096 and for the DS4200 and DS4700 to 2048. - Support Bundle Collected on Critical Events. Upon occurrence of a critical event, the monitor will save the support bundle to the local hard drive of the client system in the same area as used for other recovery information. This information will not be overwritten for at least 72 hours. - Solaris 10 x86 support. Solaris 10 x86 has been supported in a previous release as an I/O attach only solution. This will add GUI (Client, agent, utils) support to the solution. There is no RDAC support. The failover mechanism will be MPXIO (native to the OS) or DMP where supported by Symantec. - Enhanced Diagnostic Data Capture for additional failure events. - Increase number of Global Hot Spares(GHS). Lifts any previous limits on the number of GHS allowed per array - Drive Migration Warning. When migrating configured arrays to an existing Storage Subsystem there will be a warning given if the number of Logical Drives being added will overrun the maximum number of logical drives allowed on this particular Subsystem. This will allow to user to manually intervene and aid in safer migration scenarios. This will prevent the user from being allowed to import more logical drives volumes than a particular controller is supposed to support. - Eliminate import of SAFE keys from foreign drives. Eliminate the import of premium feature keys when merging a foreign database to eliminate the unnecessary marking of premium features as “enabled-unauthorized? - Uniform noncompliance/not-within-limits behavior. Create uniform behavior for situations in which a premium feature has a non-compliant/not-within-limits condition, regardless of which feature it is and how it was enabled (SAFE key or feature pack). - Configurable failed drive replacement. The user will be allowed to specify that a hot spare be a permanent member of an array, thus eliminating the copyback portion once the failed drive has been replaced. The replacement drive in that case will be in an unassigned state. - Controller Response Time Performance Statistics. Controller response time and Drive I/O statistics will be available SYMbol i/f. This is needed by Storage Performance Analyzer and in support of SMI-S 1.1. These statistics will not be used by the SANtricity GUI at this time. - Support drive statistics collection through SYMbol interface. Log Sense commands are currently being used to collect the drive stats because they are not available through SYMbol. These should be added to SYMbol. This will also support SMI-S 1.1. These statistics will not be used by the Storage Manager GUI at this time. - Performance Statistics ?Processor Utilization. Needed by third party performance tools and will be needed by the new SMI provider in the near future. - Move to Java 1.4.2 compiler. - Update SMI-S provider. A provider (or providers) that support SMI specification versions 1.0.2 and 1.1. - Improve “Degraded?drive-side channel state detection - Support Telnet protocol on controller Ethernet ports. Support the telnet protocol on the controller Ethernet ports. - Support MS Vista Client. Provide client-only support for the new Microsoft client release, Vista. This is for management only and is not supported as an I/O attach solution. - RAID redundant data verification prior to read. Enable verification of redundant RAID data consistency before returning the requested read data back to the host. This feature should be enabled on a logical drive basis. It will automatically be disabled when a logical drive is degraded. If a mismatch is detected, the controller will return a Media error ?unrecoverable read error (03/11/00). The subsystem will not attempt to correct or recalculate parity automatically. This will support all raid levels. - 8K cache block size. - Increase to 16 snapshots per logical drive for DS4800. - Snapshot recreate process improvement. - Support RedHat v5.0 and SLES10 SP1. - Increase number of mirrors supported. Increase the number of mirrors supported on DS4800 from 64 to 128 and on DS4200/DS4700 from 32 to 64. - Increase # of Flashcopies on DS4200/DS4700/DS4800. Increase the number of Flashcopies per logical drive to 8 for DS4200/DS4700 and 16 for DS4800. - Increase # of Remote Volume Mirrors on DS4200/DS4700/DS4800. Increase the number of RVM mirrors allowed to 64 mirrors for the DS4200/DS4700 and 128 mirrors for the DS4800. - Create Unmanageable Icon. Create a new icon in the EMW to differentiate between “Unresponsive?and “Unmanageable? The unmanageable would be any Controller Subsystem for which there isn’t the corresponding JAR file. - Incorporate the following field defect fixes: - Fix 345023 CR 111414 DS4800 XBB Does not Allow Different Gateway Addresses For Ethernet Ports Description: The function to assign each port on a controller different gateway IP addresses did not exist. Each controller was supported with the capability to have only one Gateway Where Seen: During the setting of gateway IPs for for different controller Ethernet ports to a different IP. Note: The DS4800 does not support the preceding exercise. IP address for both its ports. This was by design. Symptons: If user enters 2 different Gateway values for the ports on the same controller, the follow error message will be displayed: Title: Gateway Mismatch Icon: Red Error X icon Text: The Gateway must be the same for all ports on a controller. Resolution: Storage Manager has been recoded adding the ability to set controller Gateway IPs with different values on the DS4800. - Fix 356903, CR115802/CR114353 Alert Notification, Password Set Creates Empty StateCaptureData.dmp Description: Customer Windows language setting is set to Turkey. Pulling a Subsystem Profile file with this language setting will cause the string "LOGICAL DRIVE NAME:" to change "LOGÝCAL DRÝVE NAME:". This in return will have an impact on the Datacase Support tool which decodes the Storage Subsystem File. The Datacase tool will not be able to identify the string anymore which will cause an incorrect/missing decoding of the volume configuration of the Subsystem Where Seen: During OS language setting. Seen with Strorage Manager 0 9.19.G5.06. and Controller Firmware versions: 06.12.x, 06.16.x, and 06.19.x . Symptom: Invalid characters observed in profile LOGÝCAL DRÝVE NAME CAPACYTY - Fix 360139, CR117846 Wrong Host Port 2 Message When Activating RVM Should Be Port 4. Description: When an attempt to activate the Remote Mirroring Feature on DS4700-72A (4xHost Ports on each controller), message as follows are (may be) displayed: **”All Hosts Currently using Host Port 2 will be logged out" **Host Port 2 will be reserved for mirror data transmission. All host communication to the storage subsystem on host port 2 will be rejected as long as the feature is active" CFW is reporting a tray type of TRAY_TYPE_FC4600 which is correct, but the datum is not specific enough for host software to correctly determine the number of host ports in the controller. Where Seen: With HSW versions are 09.16.G5.62; 09.19.G5.06; and 09.19.G5.11 when an attempt to activate the Remote Mirroring Feature on a DS4700-72A (4xHost Ports on each controller) Symptom: May see the message: messages: ?*All Hosts Currently using Host Port 2 will be logged out? "**Host Port 2 will be reserved for mirror data transmission. All host communication to the storage subsystem on host port 2 will be rejected as long as the feature is active" Oct 08, 2007 - Storage Manager Installer package version 09.60.35.03 - Support Windows Vista Client. Support Windows Vista as a client only OS. This will NOT support I/O attach. It is a management client only. This requires a new JRE (v1.6).DS4000 Controller firmware versions to be supported for management will be 6.12, 6.23 and 6.60. - Support cloning of persistent reservations with MPIO. Support cloning of PR in the DSM for MPIO. This will provide MPIO support for DS4000 Controllers with firmware version 6.12 and higher. All previous released versions of CFW will not be supported. - Updated Installation checks on Windows 2003. Previous releases have checked for the presence of KB916048 (storport fix) and halted the installation if this hotfix was not present. This hotfix has now been released as part of SP2. However, there is an additional hotfix (KB932755). The new installation behavior will not continue if SP2 and hotfix KB932755 is not installed. - VDS/VSS Use new ability to recreate multiple snapshots. This is associated with enhancement Recreate Multiple snapshots(see below). The SMI-S providers will updated to use the new commands for recreating multiple snapshots. - Recreate multiple snapshots. SYMbol addition of a re-create snapshot command that will accept a list of snapshots as input. This command will be used by VSS and SMI-S providers to reduce the time needed to re-create several snapshots at one time. - The management of the IBM System Storage DS3300 with controller firmware version 6.50.xx.xx installed. - Support for DS4000 Controller Firmware 6.60.xx.xx. May 10, 2007 - Storage Manager Installer package version 09.23.35.02 - Fix 370708. The IBM DS4000 Storage Manager version 9.23.G5.00, or installation package version 09.23.35.01, was not compatible with Controller firmware 06.12.56.00. Could not upgrade to 06.12.56.00 maintenance firmware level using IBM's Storage Manager 9.23.G5.00. The Storage Manager version 9.23 error message indicated the Controller firmware was not a compatible file for downloading. April 18, 2007 - Storage Manager Installer package version 09.23.35.01 - New DS4000 System Storage 4Gbps/15Krpm 300GB Fiber Channel Enhanced-Disk Drive Module (E-DDM) option - New DS4000 System Storage 750GB Serial ATA E-DDM option - The intermixing of the Fibre Channel and SATA E-DDMs within the same DS4700 storage subsystem or EXP810 drive expansion enclosure. - The intermix of EXP810/EXP710 and EXP100 enclosures behind a DS4700 and DS4800 storage subsystem. - New "Enhanced Disk Drive Predictive Fault Analysis" diagnostic feature on the DS4300, DS4500, DS4700 and DS4800 storage subsystem. The DS4000 controller will monitor and flag any the Fibre Channel and SATA hard drives in the DS4000 storage subsystem configuration with PFA error when one of the following conditions occurs a. 500 recoverable errors within a 24 hours period for Fibre Channel drives b. 4 medium errors within within a 24 hours period for Fibre Channel drives c. 8 medium errors within within a 24 hours period for SATA drives - The management of the IBM System Storage DS3200 and DS3400 storage subsystems with controller firmware version 06.17.xx.xx installed. - Incorporate the following field defect fixes - 106861 Storage Manager v9.15/9.16 Client not email rfc 2821 compliant causing validation to hang and no email alert was sent. Fixed by changing the line ending in CRLF (C332970) - 116441 SMcli command save supportData fails error code 12. Added code to set the Java System Property java.awt.headless to true for SMcli startup in CommandLineInterface.java (C355295) - 111219 (111073) PANIC Assertion failed insertCount < mismatchCount causes Recovery Guru to hang and controller to reboot. Fixed by adding an assertion check. (C344787) - 110124 Event ID:0 Shows in MEL and GUI with Red X. Fixed by changing the severity level for ESM autoSyn enable/disable message to informational. (C343472) - 109408 Mappings: Logical drive capacity not sorted correctly. Fixed by sorting the column with a long integer value for the capacity rather than a string value. (C339565) - 113673 (Cal6154) Reword expiration date warning statement for cache battery backup CRU. (C353749) - 115053 SMcli error returns error 27 using -n param specified (RSM tool) May 9, 2006 - Storage Manager Installer package version 09.16.35.42 - Support new DS4700 Storage Subsystem models 70A/H and 72A/H, which support the attachment of DS4000 EXP710 and EXP810 Storage Expansion Enclosures. - Support new DS4800 Storage Subsystem Model 80A/H, which provides the same functionality as the DS4500 Storage Subsystem, with better performance. - Support new 4Gbps Fibre Channel drives in the DS4000 EXP810 Storage Expansion Enclosure. - Support new DS4000 FC 4Gbps single and dual port Fibre Channel Host bus adapter. - Support for Fibre Channel Host Bus Adapter (FC HBA) device driver based on the Microsoft STORport miniport device driver model. Refer to the STORport FC HBA device driver readme file for the required DS4000 storage subsystem controller firmware and DS4000 storage manager host software code versions. March 26, 2006 - Storage Manager Installer package version 09.16.35.09 - To correct the ambiguous warning statement in the pop-up window, that was displayed as part of the storage manager host software installer wizard. The existing warning statement might cause the customer to incorrectly interpret that he could not upgrade the controller firmware of the DS4000 controllers in a configuration with EXP100 enclosures after he installed the new storage manager host software. This change is for the storage manager SMIA installer package only. All of the storage manager host software components will have the same version as the ones that were released on 2/13/2006. February 13, 2006 - Storage Manager Installer package version 09.16.35.08 - Support for attachment of DS4000 EXP810 Storage Expansion to the DS4800 storage subsystems with controller firmware 06.16.xx.xx installed. - Supports automatic ESM firmware synchronization with the new EXP810 storage expansion enclosure. When you install a new ESM into an existing EXP810 that is attached to a DS4000 storage subsystem that supports automatic ESM firmware synchronization, this feature resolves firmware mismatch conditions by automatically synchronizing the firmware in the new ESM with the firmware in the existing ESM. Support for automatic EXP810 enclosure ID conflict resolution. Dec 01, 2005 - Storage Manager Installer package version 09.15.xx.x6 - Support the DS4100, DS4300, DS4400, DS4500 and DS4800 controller firmware versions that provide support for the new 400G SATA drive options and CRUs (P/Ns 39M4570 and 39M4575, respectively) in addition to the new 250G SATA drive CRUs (P/N 40K6837.) This new 250G SATA drive CRU is functionally equivalent to the previously-released CRUs (P/N 90P1349). Note: The drive enclosure EXP100 ESM must also be updated to version 9563 or later. - Support controller firmware version 06.12.16.xx or higher on the DS4100 storage subsystem with Single Controller option - The DS4100 storage subsystem with standard option is now supported the DS4000 Copy Services Remote Mirroring and VolumeCopy premium features. - Fix defect C291078 (90136/89954) - when managing DS4000 controllers with firmware version 06.10.xx.xx or 06.12.xx.xx installed, highlighting the selected drive firmware update package will result in no drives being listed as compatible in the select drives for firmware updating window. - Fix defect C290432 (91773) SM9_R3 MIB Naming violation causing compilation failure - Fix defect 87085 (~86641) Unable to see free capacity node of a migrated logical drive/array - Fix 87313 (~87099) RVM Repository Volume Cache States are missing from Array - Add 87941 (~85376) Support Diagnostic Data Capture (DDC) functions in the DS4000 controller firmware - Fix defect 88007 (~87397) (C273843) RVM logical drive status is inconsistent. The storage subsystem profile and RVM logical drive properties status can indicate "Not Available" when GUI fly-over status indicates optimal, mirror synchronized. Some RVM volumes update the status correctly over time while others don't appear to change from the "Not Available" state. - Fix defect 89457 Create FlashCopy wizard Subsystem Management online help incorrect in some circumstances - Fix defect 93883 Not Printing out Stack Trace in Diagnostic Data Capture June 29, 2005 - Storage Manager Installer package version 09.15.xx.x3 - Support the DS4800 storage subsystems with controller firmware version 06.15.11.xx. With this version of firmware, the DS4800 controllers utilize all of the available data cache memory installed in each controller blade for I/O caching. Previously with controller firmware version 06.14.xx.xx, the DS4800 controllers used only the first 1G bytes of the installed data cache memory per controller for I/O caching. May 17, 2005 - Storage Manager Installer package version 09.14.xx.05 - Support the DS4800 storage subsystem with controller firmware version 06.14.xx.xx - Support the Enhanced Remote Mirroring feature option on the DS4100 storage subsystem with standard/base option and controller firmware version 06.12.xx.xx - Support the FC/SATA intermix feature option on the DS4300 storage subsystem with standard/base option and controller firmware version 06.12.xx.xx - Support for Veritas Volume Manager (DMP) version 4.2 - Support assisted technology (screen reader) for blind or visually impaired individuals Mar 18, 2005 - Storage Manager Installer package version 09.12.xx.08 - Support the DS4000 storage subsystem controller firmware version 06.12.xx.xx - Support the controller firmware version 06.12.xx.xx installed in the DS4100 storage subsystems with standard option - Support FC/SATA intermix premium feature activation via premium key file - Added wizard and task assistants in the Storage Manager Client to guide users through common DS4000 storage subsystem management tasks. Jan 07, 2005 - Storage Manager version 09.10.xx.05 (for DS4300 base option support) - Support the controller firmware version 06.10.xx.xx or higher for the DS4300 storage subsystems with standard option. Support for the attachment of EXP710 drive enclosures to the DS4300 storage subsystems with standard option. Nov 24, 2004 - Storage Manager version 09.10.xx.05 - Support for the DS4000 FC/SATA storage expansion enclosure intermix option - Enhance the DS4000 Enhance Remote Mirroring Global Copy and Global mirroring functions - Support for the attachment of EXP100 SATA storage expansion enclosures to the DS4400 storage subsystem - Support for the increase in the maximum number of EXP100 drive expansion enclosures that can be connected to a DS4100 storage subsystem. The maximum EXP100 drive enclosure that can be connected to DS4100 is now 7 instead of 4 - Support the DS4100 storage subsystem with Single Controller option - 254966 ( 81363) DS4000 controllers do not agree on configurations - 256414 ( 81441) Cannot create new LUN using FSM 9.1 / FW 6.1 - 259611 ( 82674) Cannot install SM 9.10 because of a defect in Storage Manager host software uninstall - 261681 download allenclosures firmware cmd not working correctly. - hlpct_53466 ( 80833) tcp port scan causes controllers to reboot - change MIB file name to SM9_10.MIB Aug 31, 2004 - Storage Manager version 09.10.xx.02 - Enhance Remote Mirroring support. Besides Metro Mirroring, IBM DS4000 Storage Manager version 9 also supports Global Copy and Global Mirroring Remote Mirror options. - Parallel hard drive firmware download. - Staged controller firmware download. - Full command-line SMcli support. - Improve DS4000 storage manager client Subsystem Management GUI - Adding additional diagnostic features - Drive Channel status, hard drive sector failure list. June 18, 2004 - Storage Manager version 08.42.xx.00 - Support the new DS4000 storage subsystem model - DS4100 (machine type 1724 - model 100.) May 20, 2004 - Storage Manager version 08.41.xx.05 - 73847 - Ancient IO were aborted during watchdog timeout - Support new controller firmware in DS4300 and DS4500 and EXP100 ESM firmware to enable EXP100 full High-availability support. - Support DS4000 Copy Services FlashCopy and VolumeCopy for DS4000 storage subsystems that are connected to EXP100 enclosure. Note: The DS4000 storage subsystem controller firmware version must be 05.41.5x.xx or higher. The EXP100 ESM firmware version must be 955x or higher. Apr 25, 2004 - Storage Manager version 08.4x.xx.04 - Version 08.41.xx.03 of Windows 2000 and Server 2003 RDAC that fixes these problems: 72340 RDAC event id 85 message logged during startup. The ASC\ASCQ is 0x20,0x25. Change RDAC system event log entry type from Error to Informational. 73760 ( #73735) Customize 8.34 MPP to support DS4000 string in the Inquiry Name. 74112 ( #74075) A windows 2003 Host with MPP install on the system will hang on a shutdown 74453 ( #74451) Virtual disk may not restart properly 74727 ( #74265) ( #73903) TD_PT1923 Volumes do not transfer back to original owner 74746 TD_PT2233 rdacdisk.sys needed after uninstalling RDAC Apr 09, 2004 - Storage Manager version 08.4x.xx.04 - New version of DS4000 Storage Manager version 08.4x.xx.04 to support the new DS4300 Single Controller model 6LU, 6LX, 6LJ. With this firmware version, the standard DS4300 models support the following features: - 1 Gb support for fabric switch ports and host bus adapters (HBAs) - FlashCopy premium feature