IBM Platform Symphony 7.1 Interim Fix #351726 Readme File

Abstract

If the logged on user is not assigned to any consumer and accesses the LSF jobs page, the WEBGUI service will crash and restart.

Description

When you create a new role with ¡°LSF Job View¡± and ¡°LSF Job Control¡± permissions and assign a user to this role without assigning a consumer, the WEBGUI service will crash and restart when the user logs on to the PMC and accesses the Workload > LSF > Jobs page.

After applying this fix, the WEBGUI service will not crash.

This fix applies to all supported platforms.

Readme file for:
IBM® Platform Symphony

Product/Component Release: 7.1 Fix Pack 1

Update Name: Interim Fix 351726

Fix ID: sym-7.1-build351726

Publication date: July 16, 2015

Last modified date: July 16, 2015

 

Contents:

1.     List of fixes

2.     Download location

3.     Products or components affected

4.     Installation and configuration

5.     List of files

6.     Copyright and trademark information

1.   List of fixes

APAR#P101217: If the logged on user is not assigned to any consumer and accesses the LSF jobs page, the WEBGUI service will crash and restart.

2.    Download location

Download Interim Fix 351726 from the following location: http://www.ibm.com/eserver/support/fixes/

3.   Products or components affected

Product/Component Name

Platform Symphony/PMC

4.   Installation and configuration

4.1         Before installation

1.     Stop the WEBGUI service.

> egosh user logon -u Admin -x Admin

> egosh service stop WEBGUI

2.     Back up the following files:

> $EGO_TOP/gui/3.1/lib/commons-ego.jar

> $EGO_TOP/gui/3.1/lib/egogui.jar

4.2        Installation steps

1. Decompress the sym7.1-build351726.tar.gz package.

2. Copy the files to the following directory on the management hosts:

> cp commons-ego.jar $EGO_TOP/gui/3.1/lib/

> cp egogui.jar $EGO_TOP/gui/3.1/lib/

4.3          After installation

1. Clean up the GUI work directory and the browser cache by deleting all subdirectories and files in this directory:

> rm -rf $EGO_TOP/gui/work/*

2. Start the WEBGUI service.

  > egosh user logon -u Admin -x Admin

> egosh service start WEBGUI

4.4          Uninstalling

 1.   Stop the WEBGUI service.

> egosh user logon -u Admin -x Admin

> egosh service stop WEBGUI

2.    Restore the following files on all management hosts with the backed-up files:

> $EGO_TOP/gui/3.1/lib/commons-ego.jar

> $EGO_TOP/gui/3.1/lib/egogui.jar

3.    Clean up the GUI work directory and the browser cache by deleting all subdirectories and files in this directory:

> rm -rf $EGO_TOP/gui/work/*

4.    Start the WEBGUI service.

> egosh service start WEBGUI

1.   List of files

commons-ego.jar

egogui.jar

2.   Copyright and trademark information

 

© Copyright IBM Corporation 2015

U.S. Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

IBM®, the IBM logo and ibm.com® are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.