APAR# | Description |
IV19540 | powerha cspoc mkvg operation generates sfw "no such device" |
IV24756 | powerha may change vg timestamp every time a rg is acquired |
IV25132 | powerha 7.1 may set manage resource groups to manually. |
IV28693 | mkcluster cmd fails for third party disks. |
IV30418 | rpc.lockd running in wpar causes rg error state |
IV32711 | cl_sync_vgs shows misleading error message in hacmp.out |
IV32824 | powerha varyon of concurrent vg(s) in a concurrent rg(s) fails. |
IV34310 | release notes are incorrect on caa network failure detection |
IV34311 | director is not notified of volume group creation/changes. |
IV34312 | cli_mklv may fail with more than nine arguments. |
IV34313 | last free disk may not be shown in picklist for smit cl_createvg |
IV34314 | scdiskutil incorrectly reports dynamic tracking status |
IV34315 | snap -e doesn't collect the clmkcaa.log file |
IV34316 | clcomd cannot communicate sometimes |
IV34317 | powerha: the rpc.lockd daemon may not be active after an rg move |
IV34318 | corrective action associated with wpar cloning fails |
IV34319 | powerha node start fails after forced down |
IV34320 | ha clstrmgr coredump on all nodes after start cluster services |
IV34321 | smit cannot remove multiple files from file collection |
IV34322 | cspoc list fs displays sed errors, cannot handle fs corruption |
IV34323 | powerha configure "critical volume groups actions" will fail |
IV34326 | no available space data is provided for non-local disks. |
IV34327 | child rgs should not bounce on restart after clstop unmanaged |
IV34328 | correctly manage volume group state vis a vie fence height |
IV34329 | ha: auto cluster config monitoring smit error in japanese locale |
IV34330 | concurrent vg varied on non-concurrently if disks missing |
IV34331 | no disks shown in mirror pool |
IV34332 | powerha dlpar failure at power7 lpars |
IV34334 | diskhb configuration not possible due to discovery problems |
IV34335 | powerha: cluster services do not start automatically on boot |
IV34336 | clinfo api incorrectly returns an additional cluster with id 0 |
IV34337 | clrginfo -m truncates long application server names |
IV34338 | halevel -s may not return correct information about service pack |
IV34339 | clpasswdremote core dumps due to memory fault |
IV34350 | volume group management occassionally fails |
IV34400 | powerha discovery fails to discover tty devices |
IV34567 | lost svc, rg does not falover to remote site |
IV35757 | conc migratepv results in a remote node failures |
IV36474 | misleading c-spoc error when jfs log is specified |
IV36475 | rg left offline at fallover after monitor and node failure |
IV36525 | clmgr fails to add a vg to an existing non-concurrent rg |
IV36757 | error message could contain garbled application server |
IV36758 | cl_auto_versync fails for caa at cluster startup |
IV36759 | powerha: smitty cl_chfs fails to change log device |
IV36760 | clrginfo -m flag not documented |
IV36761 | cspoc 'synchronize lvm mirrors' fails with 2 pvs missing/removed |
IV36762 | resource acquire error during dare but rg left in online state |
IV36763 | director sometimes displays incorrect volume group name |
IV36764 | correctly display owning resource group for filesystem |
IV08719 | pkm_kern and syslogd high cpu% after repository disk replaced |
IV09273 | clsnap does not collect the clevents log file |
IV12506 | powerha 7.1 clver corrective action may fail. |
IV12508 | clverify doesn't check the subnet of service/boot ip address |
IV13207 | nfsv4 application monitor output fills up /var directory |
IV14987 | c-spoc create/change filesystem fails due to disk fencing |
IV15822 | wrong application monitor used at startup if two different types |
IV16008 | powerha process_resources may fail due to reuse of a work file. |
IV16052 | clgetaddr will core dump if nodename is invalid |
IV16921 | using c-spoc with asm devices can cause data loss |
IV18985 | powerha dare fails leaving cluster in unstable state |
IV19644 | powerha clstrmgr daemon may core dump. |
IV19804 | cspoc menus show error: cl_lspvsmit printif not found |
IV20223 | interface routes lost after release service addr |
IV21212 | powerha fails to lower fence height before deleting fence group |
IV23772 | nfsv4 application monitor fails if /tmp full |
IV25596 | incorrect PowerHA menu in smit |
IV25962 | dare reconfig_resource_complete encounters cat error |
IV25965 | configchk error failed to distribute hacmpnode odms |
IV25966 | unable to discover the dns using smart assist |
IV25967 | clver crashes due to memory corruption caused by buffer overflow |
IV25968 | cspoc extendvg cannot add multiple disks in a single invocation |
IV25969 | changing filenet process engine smart assist fails wit |
IV25972 | customized resource monitor removal leaves odm entries |
IV25973 | ha verification configures ipv6 ll address on all interfaces |
IV25974 | glvm syncvg called in foreground causes long events |
IV25975 | error message found while creating enhanced journaled fi |
IV25976 | cspoc lv name change doesn't update /etc/filesystems on passive |
IV25977 | clmgr delete cluster behavior does not match man page |
IV25979 | cspoc swap ip address menu shows incorrect list of interfaces |
IV25980 | cl_godm_func.c", line 21.13: 1506-334 (s) identifier sc |
IV25981 | libodm criteria incorrect msg if fcmodtime filename has spaces |
IV25983 | concurrent rg is not listed for scalable concurrent volu |
IV25984 | cspoc swap ip address menu shows incorrect list of interfaces |
IV25985 | repository disk size limits for powerha system mirror 711 |
IV25986 | remove clver check for svc ip in db2nodes.cfg |
IV25987 | adding service ip label has different distribution preference |
IV25988 | automatic cluster verification removes ipv6 service ip |
IV25989 | smit clstop values are changed after aix shutdown -fr |
IV25990 | clvgdats may coredump/error for svg with many pps |
IV25991 | cluster handle reset on list operation |
IV25992 | clvaryonvg does not varyon the volume group if bad block in vgda |
IV25993 | hacmp not logging for in /usr/es/sbin/cluster/.gsclvmd always |
IV25994 | vg fails to vary on passive-concurrent after being forced off |
IV25995 | clrginfo -m returns app offline for rgs online at remote node |
IV25996 | mndhb logical volume label with spaces causes error |
IV25997 | powerha "add a disk to the cluster" may generate 1800-018 error. |
IV25998 | clmgr query disk can fail if node is not in fqdn format |
IV25999 | powerha clfileprop may error by sending data to the local node. |
IV26000 | clmgr cannot accurately retrieve/display ipv6 addresses |
IV26001 | c-spoc extendvg does not pick up mirror pool name |
IV26002 | missing network information in director. |
IV26003 | clstrmgr core due to incorrect handling of internal rg nodelist |
IV26004 | occasional cl_rsh/clcomd communciation errors. |
IV26005 | ha start may not complete starting three or more nodes at a time |
IV26006 | clmgr query fs does not handle the fs not being in an rg |
IV26007 | clmgr query node returns an ip address for the hostname |
IV27235 | verification shows incorrect free disk space recommendation |
IV27236 | dare fails after changing a network to hb over alias |
IV27237 | ibm.hacmprgrmd deamon may core dump |
IV27238 | remove spurious output from cl_mkvg and cl_mklv |
IV27239 | ibm.hacmprgrmd can't load with symbol resolution failure |
IV27240 | verification reports an error when nfs exporting a subdirectory |
IV27242 | fuser may hang in cl_deactivate_fs.sh |
IV27243 | cl_mode3 should delete vg.fail on successful varyon of a vg |
IV27244 | ha smit generating the hdisk picklist for extendvg takes hours |
IV27245 | while running cl_syncvg, 0516-938 error occurs |
IV27246 | after failover due to errnotify, rg stays in rg_temp_error_state |
IV27247 | settling timer causes manually managed rgs to be online |
IV27248 | powerha cspoc operations fail to restore disk lock |
IV27249 | ibm.hacmprgrm crash when application server in more than one rg |
IV27250 | oracle smart assist adds only 1 listener stanza in odm |
IV27251 | clrgmove -p results in continuous while loop |
IV27252 | clver error - the parent directory is already in export list |
IV27253 | ha cannot move rg 27 and 28 to secondary node |
IV27254 | clinfo socket exhaustion causes dms timeout |
IV27255 | rpv client driver unconfig method |
IV27256 | non-disruptive upgrade causes clstrmgr coredump |
IV27257 | user-defined resource script incorrectly put in background |
IV27258 | cspoc 'synchronize lvm mirrors' failure |
IV27259 | no gui dialog box to type new password when using gui cspoc |
IV27625 | cluster manager dumps in some cases |
IV29162 | corrupted resource group field from "clmgr query file_system" |
IV29244 | dare fails with message "0403-053 expression is not complete" |
IV00109 | fcp error logged in errpt for mndhb disks when using npiv |
IV00438 | ha 7.1 clver output incorrectly ordered when executed via smit |
IV01097 | clver may incorrectly report an error that nfs server is down |
IV01527 | cspoc reducevg fails to remove a pv from a shared vg |
IV01808 | clver incorrectly reports lpar with id 1 as non dlpar capable |
IV03098 | clevmgrd core |
IV03524 | cspoc fails to assign a scalable vg to a mirror pool |
IV03598 | gsclvmd not started after reboot for forced down node |
IV04677 | clstrmgr does not terminate as requested at shutdown |
IV06840 | unable to change custom resource recovery method |
IV06927 | ip harvesting code displays the wrong catalog message in ja_jp |
IV07356 | powerha fails to delete existing vg fence groups |
IV07412 | klib utilities are printing messages to console |
IV07560 | cspoc increase lv size fails with aix mirror pools configured |
IV07563 | cl_chfs operation processes incorrect -a value in ja_jp locale |
IV07923 | cl_autover_sync executes incorrect calls to date command |
IV08518 | sfwaddfencegroup returns no such device if two or more disks |
IV08574 | clevmgrd displays misleading event fd errno information |
IV08889 | cannot change critical volume group action |
IV08890 | nfsv4 app monitor script takes too long during busy rootvg state |
IV08891 | smit errors if nodename is a substring of 'when' |
IV08892 | invalid character contain lv name "*lv" fails with wrong |
IV08893 | ha may loop when releasing virtual procs via dlpar |
IV08894 | robustness improvement for resource group moves |
IV08897 | clmgr rg output param does not match input param |
IV08898 | provide c-spoc support for mklv/chlv -p, -u and -g operands |
IV08899 | clver should error if nfs exported directory does not exist |
IV08900 | clstrmgr can core dump dare during server_down or server_restart |
IV08901 | lssrc -ls clstrmgres shows incorrect event queue information |
IV08902 | changing participating nodes for maxdb application remo |
IV08903 | nfsv4 monitor script execution time improvements |
IV08904 | cllsvg -s prints incorrect output |
IV08905 | clmgr's automatic help is sometimes not helpful |
IV08906 | cspoc cli_replacepv failure |
IV08907 | clver dumps core after adding filenet smart assis |
IV08908 | applying snapshot with hboveralias base address of 3-octet fails |
IV08909 | c-spoc mirror pool support gets errors on aix 5.3 |
IV08910 | cl_ls_shared_vgs fails when alt_install rootvgs present |
IV08911 | mirror vg fails in pha6.1 sp5 |
IV08912 | resource group selection 'all' causes error |
IV08913 | stopping sddsrv causes config_too_long |
IV08914 | automatic /etc/hosts updates can erase the original data |
IV08915 | clstat -i incorrectly shows multiple clusters with id 0 |
IV08916 | changes for event scripts for old sdd versions |
IV08917 | ofan rg with settling timer incorrectly set to temp error |
IV08918 | "clmgr verify cluster" operation always returns 1 |
IV08919 | ofan rg incorrectly handled at reintegration in cfg with sites |
IV08920 | view report -application availabilty- .dirrpt error |
IV08921 | not able to add more than one maxdb instance. |
IV08922 | cspoc change/show vg menu generates lqueryvg error in cspoc.log |
IV08923 | director does not always auto-discover systemmirror clusters |
IV08925 | cluster stop may cause node halt |
IV08926 | misc_data not passed to restart, cleanup or notify methods |
IV08927 | cspoc remove fs fails on clusters with more than 2 nodes |
IV08928 | powerha cluster verification may fail with cldare syntax error. |
IV08929 | permissions of the /.rhosts file on a wpar resource group |
IV08930 | cspoc cli_extendvg man page update |
IV08931 | concurrent rg state does not transition from acquiring to online |
IV08932 | cl_auto_versync does not open correct clverify.log |
IV08933 | cspoc vg commands fail on aix 5.3 due to new mirror pool feature |
IV08934 | conversion of "normal" format vg to "scalable" fails |
IV08935 | cannot change network properties |
IV08936 | cspoc does not check if fileset bos.clvm.enh is installed |
IV08937 | cspoc: add support for lv name changes in a concurrent env |
IV08938 | missing interfaces from "clmgr query interface" |
IV08939 | lazy update may not work on scalable or big vgs |
IV08940 | volume groups in add volume group window for rg |
IV08941 | the discovered diskhb devices are not shown by smit |
IV08943 | cannot add node to empty cluster |
IV08944 | selective failover on interface failure failed for maxd |
IV08945 | cspoc.log has lqueryvg error message when creating a new fs |
IV08946 | fix level 0 returned by clstrmgr on src long status request |
IV08947 | incorrect node status in director |
IV08948 | clmgr get rg state emits and error |
IV08949 | some powerha files have no group |
IV08950 | verify and sync fails after adding a new node to alread |
IV08951 | cspoc reducevg shows misleading error message |
IV08952 | routes added in rc.net associated with persistent ips not added |
IV08953 | smart assist for oracle fails to discover the listener data |
IV08955 | remove disk from mirror pool fails when more than one disk |
IV08956 | cspoc filesystems smit menus show basename usage error |
IV08957 | typo in cluster.es.cspoc.cmds.il |
IV08958 | create cluster wizard cannot list shared disks |
IV08959 | no netmask displayed for interface using clmgr query |
IV08960 | proc_units is lower estimated on shared mode lpar |
IV08961 | director storage panel only displays one logical volume |
IV08963 | cannot create snapshots: clsnapshotinfo fails |
IV08964 | smit clstart shows a misleading message with a forced down node |
IV08965 | error messages when cluster is removed |
IV08966 | "relative path name" of catalogue file passed to catopen |
IV08967 | redundant entries in /etc/hosts when using director |
IV08968 | clmgr monitor queries always list only one application |
IV10658 | clevmgrdes is not started during node up |
IV11091 | deprecated fields should be removed from smit |
IV11095 | clmgr does not emit an error for duplicate service ips |
IV11096 | correctly assign pvids and handle disk fencing |
IV11097 | halevel command can error due to no hashbang line |
IV11099 | clsnapshotinfo fails on /usr/sbin/dspmsg |
IV11100 | remove references to cross-site lvm mirroring verification |
IV11102 | director cannot create an appmon with two app controllers |
IV11628 | change/show fs cspoc fails to continue with bad vg |
IV11732 | complete cluster auto-configuration support in director |
IV11733 | some smart assists do not work from director |
IV11734 | obsolete cspoc fastpaths for filesystems menus still available |
IV12695 | clmgr fails when application monitor script has an argument |
IV12908 | processing of exec failures in cluster manager is inadequate |
IV12909 | mndhb failure action is incorrectly processed by cl_fence_vg |
IV12910 | mount guard support |
IV12911 | cspoc disk replacement fails |
IV12914 | "clmgr query host" can return short host name |
IV12915 | onlinerent rg state does not transition from acquiring to |
IV12916 | viewing a non-existent log with trace enabled gives bad error. |
IV12923 | clexit.rc : unexpected termination of clstrmgres |
IV12956 | synchronizing lvm mirrors failed as it cannot determine |
IV12969 | clexit.rc : unexpected termination of clstrmgres |
IV13112 | cannot import a volume group via c-spoc |
IV13113 | gsclvmd not started error message |
IV13116 | cod improvments |
IV13117 | arithmetic syntax error in hmc_cmd |
IV13137 | creating new jfs2 fs failed |
IV13138 | limited repository disk size cause the cluster unable to create |
IV14287 | clmgr delete cluster emits rmcluster error message |
IV14288 | obsolete cspoc fastpaths for filesystems menus still available |
IV14289 | clmgr 7.1.0 changes to support use of 7.1.1 director plugins |
IZ94625 | automatic cluster configuration monitoring does not work |
IZ96236 | accomodate aix 7.1 ksh93 changes |
IV01805 | clsnap must collect /etc/rc.nfs and rc.tcpip |
IV01807 | cldare check on /tmp free space is not robust enough |
IV01809 | incorrect fallover during ha start of node at site with id 1 |
IV01810 | cl_createvg fails for oem multipathing software |
IV01811 | some security setup errors can result in dspmsg error |
IV01812 | ha fails to add or remove proc units via dlpar at power7 lpars |
IV01813 | non-root user cannot execute cltopinfo |
IV01814 | misleading error message in clutils.log should be revised |
IV01815 | dlpar smit help message needs more descriptive explanation |
IV01816 | verification error message for fileystem automount |
IV04041 | clrginfo -m returns app state offline for rgs online at remote |
IV04042 | 0403-004 test error message during verify and sync (cldare) |
IV04044 | cannot start cluster nodes on ha71 sp4 spin a |
IZ90890 | powerha fails to start application in local wpar environment wh |
IZ91056 | node went to rp_failed state, after changing the servic |
IZ94266 | view event summaries does not work powerha 7.1 |
IZ94336 | swap_adapter fails after ifconfig delete of service alias ip |
IZ96142 | powerha 7.1 sp2 & sp3 cluster.es.client.lib causes lppchk errors |
IZ96162 | frequent pollpersistentevents messaages logged to clstrmgr.debu |
IZ96163 | autoverify.log should contain timestamps |
IZ96165 | clinfoes is unresponsive after dare. |
IZ96166 | clstop prematurely calling clexit.rc leads to node halting |
IZ96167 | cl_rc.cluster and rc.cluster documentation and man page. |
IZ96168 | adding more than one stable storage path to a rg should fail |
IZ96170 | ha needs to enable environment variable for wlm |
IZ96171 | rpc ports are opened from clstrmgr |
IZ96172 | powerha nfsv4 crossmounts failing with vmount error |
IZ96173 | unique vg pvid sharing duplicate vgname causes clstrmgr core |
IZ96174 | ha processing will leave events on the queue |
IZ96175 | systemmirror smit stanza has next_id to itself. |
IZ96176 | some systemmirror smit fastpatshs are broken |
IZ96177 | application monitor exit in unmanaged state shouldn't impact rg |
IZ96178 | failure to update rg dependencies causes odm delete |
IZ96179 | clrgmove does not put the rg on the highest priority node |
IZ96180 | clmigcheck logs not pulled into clsnap |
IZ96181 | unable to add process engine rg from smart assist scree |
IZ96182 | db for pe rg creation fails from smart assist smit scre |
IZ96183 | smit related problems |
IZ96184 | clissuepage does not provide object name for all events |
IZ96185 | default routes may disappear on current releases of aix |
IZ96186 | unable to change/modify the content engine(ce) from sma |
IZ96187 | change/modify the webshere application server functiona |
IZ96188 | clean up is not happening completely when process engin |
IZ96189 | "ifconfig en# down detach" does not correctly mark adapter inte |
IZ96190 | unexpected clverify_daemon.log in the root directory |
IZ96191 | cspoc mirrorvg with sync mode equal background does not sync |
IZ96192 | add director logging for more events in event manager |
IZ96193 | smit clstop does not preserve values set previously by the user |
IZ96194 | message "failed to distribute odm" incorrect |
IZ96195 | the service ip label may be left on a failed interface |
IZ96196 | ha may try to use fuser incorrectly when deactivating vg |
IZ96197 | clas_n...nfsv4 resources from all rgs fails to remove |
IZ96198 | clver may core dump during fast connect processing |
IZ96199 | powerha godm calls fail when address 0.0.0.0 resolves |
IZ96200 | db2 smart assist fails to stop db2 instance correctly |
IZ96201 | additional changes to avoid clver core dump if ip labels missin |
IZ96202 | incorrect nfs exportfs execution leads to resource group failur |
IZ96203 | spurious error messages from get_disk_vg_fs |
IZ96205 | cannot modify vg settings via smit |
IZ96206 | u... clstop does not preserve values set previously by the |
IZ96207 | cluster verification not detecting invalid nfs export config |
IZ96208 | release_vg_fs syntax error prevents unmounting of filesystems |
IZ96209 | clrginfo -m returns app state offline for rgs online at remote |
IZ96210 | c-spoc file system creation fails if volume group not on line |
IZ96211 | ha dare may not work with hostname that contains boot |
IZ96228 | resource group policy changes creates invalid configs |
IZ96229 | sccsid redefinition caused a build error |
IZ88293 | director events improvements in clmgr |
IZ88294 | clmgr performance improvements |
IZ88295 | cannot move persistent ips to new interface using clmgr |
IZ88296 | clmgr fails to delete an online cluster |
IZ88297 | changing the service ip of nfs rg in dare makes rg move |
IZ88298 | serviceability improvements for clmgr |
IZ88299 | clmgr does not display current interface for persistent ips |
IZ88300 | clmgr displays no files for specific file collection queries |
IZ88301 | cannot delete non-synchronized cluster definition using clmgr |
IZ88302 | clmgr does not allow fallback timer frequency to be changed |
IZ88303 | clmgr is not displaying cluster security settings properly |
IZ88304 | clmgr stop cluster/node manage=unmanage returns a non-zero |
IZ88305 | clmgr does not work well with concurrent resource groups |
IZ88493 | clmgr cannot display multiple new networks until a sync is done |
IZ88494 | clmgr will not work properly with start/stop after dependencies |
IZ88495 | add cluster ip address to cltopinfo output |
IZ88542 | some cluster changes do not indicate a sync is required |
IZ89247 | c-spoc mirror pool support and other requirements |
IZ89249 | potential security issue. |
IZ89250 | serviceability improvements for clmgr |
IZ89251 | director events improvements in clmgr |
IZ89252 | clmgr displays no files for specific file collection queries |
IZ89269 | enabling cluster security from director causes clcomd to hang |
IZ89519 | specifying a custom log file for verification does not work |
IZ89520 | dependency listings can be incomplete with clmgr |
IZ89933 | cluster always shows unsynced after a director refresh data op |
IZ89934 | clas_n...nfsv4 resources from all rgs fails to remove |
IZ89935 | the cluster deletion code can emit an unhelpful error message |
IZ89937 | trace output can be displayed in director error messages |
IZ89938 | syntax error displayed when create cluster fails |
IZ84855 | cmp_inet_addr matches null addresses to non-null addresses |
IZ84856 | found errors in hamcp.out regarding the start of db2 in |
IZ84858 | clver may core dump when parsing /etc/hosts |
IZ84859 | clinfo.log error message at cluster startup |
IZ84860 | critical vg failure action "notify" not handled |
IZ84861 | db2 smart assist fails to create db2 rg if volume groups are ec |
IZ84862 | rg move didn't bring rg offline on the original node |
IZ84863 | cluster in unusable state after multiple pprc link failure |
IZ84864 | non-concurrent rg goes online on two nodes after move |
IZ84865 | cl_set_vg_fence_height errors in hacmp.out |
IZ84866 | accepts duplicate attributes |
IZ84867 | modification of user defined resource is not reflects in |
IZ84868 | clstrmgr start failed with syntax error |
IZ84869 | snapshot restore failing when no cluster present |
IZ84870 | maxdb instances are not getting discovered. |
IZ84872 | orig config not restored when anything goes wrong in cha |
IZ84873 | smart assist support is incomplete - clmgr |
IZ84874 | rgmove may fail if jfs2log device contains a label in the cuat |
IZ84875 | adding was application with an already existing sa fail |
IZ84876 | no error when creating duplicate start_after dependency |
IZ84961 | application failure is not detected by the powerha clust |
IZ84967 | the security level setting is not honored. |
IZ84968 | cl_mirrorvg does not handle '-s' flag correctly |
IZ84971 | clcomd logs not being picked up by clsnap |
IZ85006 | lvm_sa_quorclos not set |
IZ85008 | node halted, no takeover on backup node if sigterm received |
IZ85009 | exception when opening storage tab from cluster mgmt gui |
IZ85010 | clver may misdiagnose an nfs mount point as being in a shared v |
IZ85011 | clam_nfsv4 added with incorrect hung monitor signal |
IZ85012 | unable to change/modify the process engine (pe rg) from |
IZ85013 | error messages with snapshot creation/restore |
IZ85021 | adding file collection using clvt is behaving bit weird |
IZ85022 | failover problem 5.1.1 |
IZ85039 | adding more than 5 nodes failed in standard path |
IZ85248 | add missing smit functions to clvt |
IZ85759 | problems with clmigcleanup in sp2 |
IZ86602 | unable to change/modify the webshere application server |
IZ86606 | a running cluster cannot be deleted from director. |
IZ86612 | for ha610 sp3 spin a i am running into a cascading config probl |
IZ86613 | process startup monitor does not honor the instance count |
IZ86616 | problem with sa for sap's manual config mode and file collectio |
IZ88053 | ha_reg: unable to add print subsystem server smart assist |
IZ83245 | remove cluster definition from all nodes set to false i |
IZ83256 | cluster disk replacement is not listing the disks |
IZ83257 | rg moves to error state with nfsv2v3v4 exportfs |
IZ83260 | cannot view start/stop after dependencies in director |
IZ83261 | node priority policy cannot be set to least or most with clmgr |
IZ83266 | maxdb,domino,dhcp can not be configured from director |
IZ83268 | removal of rsct-eventmanagemtn code cause regression-existing d |
IZ83280 | hacmpresourcetype odm is hardcoded for 1 wrong entry. |
IZ83281 | deleting and adding the same node in a 2 node cluster c |
IZ83282 | no smart assist listed in rgw |
IZ83283 | rgw miss the option choice on step4 |
IZ83284 | unlock the caa function in aix |
IZ83397 | customer won't be able to use sa for ihs |
IZ83398 | clchappmon updating the same monitor multiple times |
IZ83410 | sap ers instance addition failed with the following |
IZ83411 | unable to create instlist rp2 information in packages/cluster/e |
IZ83412 | repository disk does'nt show with f4 |
IZ83413 | not able to change custom verification method name. |
IZ83460 | ship updated html for 710 |
IZ83483 | changing the service ip address in the dare is giving er |
IZ83747 | don't know how to make ibmdita.css. stop |
IZ83751 | clverify fails with unlock problem. |
IZ83761 | autoverification is not triggered when starting clu |
IZ83765 | change/show service label is adding a new service l |
IZ83789 | updates to clsnap for 71 |
IZ83790 | sap scs and ers instances are running on same node. |
IZ83791 | remove cluster from all nodes does not remove caa cluster |
IZ83793 | resource groups cannot be brought on/off line on specific nodes |
IZ83796 | readme updates for 710 sp1 |
IZ84083 | syntax error missing " in cluster.es.client.lib.post_u.sh |