========================================================================= Sterling Secure Proxy (SSP) 3.4.00 Patch 6 iFix 1 Maintenance - May 2013 ========================================================================= This maintenance archive includes the GA release of SSP Engine 3.4.0 and SSP Configuration Manager 3.4.0 plus the fixes for the issues mentioned below. Contents: I. Summary of Fixes by Patch (Latest patch first) II. Detailed Description of Fixes I. Summary of Fixes by Patch (Latest patch first) =============================================================================== Summary of Fixes for SSP 3.4.0.6 (3.4.00 Patch 6) iFix 1 Build 153 (May 2013) =============================================================================== RTC368508/IC90590 (PS) - Perimeter Server fails to come up after SSP3406 install on Solaris RTC367240/IC90704 (CM) - Disable CM autocomplete of password field RTC367009/IC90714 (CM) - CM application pages do not break out of third party frames RTC367003/IC90712 (CM) - Version information revealed in HTTP header RTC367002/IC90711 (CM) - CM Inadequate application error handling =============================================================================== Summary of Fixes for SSP 3.4.0.0 Patch 6 Build 150 (November 2012) =============================================================================== RTC336420/IC85514 (CM, Engine) - Loop getting "Fast wakeup condition detected" RTC336514/IC87275 (CM) - Duplicate SSH public key with different name in Authorized Keystore causes key authentication to fail RTC341834/IC85733 (Engine) - SFTP intermittently not returning the SSH server identification string during session startup RTC347314/IC87274 (CM) - Admin able to add same named C:D node within netmap if name is in mixed case. RTC347347/IC87266 (CM) - SFTP Post-Authentication Banner Text appears before client authentication RTC348461/IC86820 (CM, Engine) - SSP on Solaris using 32-bit version of JRE RTC350243/IC87276 (CM) - Unable to stop CM with stopCM.sh and no indication why RTC351025/IC87649 (CM, Engine) - SFTP adapter session limits enforced globally rather than at the adapter level. =============================================================================== Summary of Fixes for SSP 3.4.00 Patch 5 Build 148 August 2012 =============================================================================== RTC330660 (CM, Engine) - Jetty PSIRT Advisory 258 - DOS Hashmap attack =============================================================================== Summary of Fixes for SSP 3.4.0 Patch 4 Build 147 (May 2012) Fixes are marked as Engine, CM (Configuration Manager), and GUI (Admin GUI) =============================================================================== RTC103849 (CM - Installation) - SSPCM will not start after upgrade if dfltKeyStore.xml file is missing RTC288193 (CM GUI) - SSP UI tables not displayed under FireFox 9.0.1 RTC315035 (Engine) - HTTP Header size rejected as too large RTC321975 (CM - Installation) - SSPCM will not start after upgrade from SSP 3.2 RTC322562 (Engine) - FTP EPSV and EPRT commands not correctly handled in SSP RTC322567 (Engine) - SSP aborts session if CDSA sends DSEQ in FM71 ================================================================================ Summary of Fixes for SSP 3.4.0 Patch 3 Build 146 (March 2012) Full descriptions below. Fixes are marked as Engine, CM (Configuration Manager), and GUI (Admin GUI) ================================================================================ RTC319700 (Engine - PeSIT adapter) - PeSIT messages support and outbound PeSIT node trace have been added. ================================================================================ Summary of Fixes for SSP 3.4.0 Patch 2 Build 145 (February 2012) Full descriptions below. Fixes are marked as Engine, CM (Configuration Manager), and GUI (Admin GUI) ================================================================================ RTC140648 (Engine) - Correctly load the Step Permission values from the PNODE policy for each new CD session. RTC140686 (Engine) - Tectia SSH sftpg3 command line client unable to connect to SSP RTC140514 (Engine) - SFTP Adapter rejects sessions specifying SFTP protocol 5 or 6. RTC140683 (Engine) - Secure+ Timeouts during download of large files RTC140524 (Engine) - CSP900E Logged Exception due to long PCRT value in C:D FMH70 RTC310391 (Engine) - SFTP connections fail when multiple authentication methods defined in netmap RTC311930 (Engine) - In FIPS mode, SSP log shows Invalid Key Strength: 512 RTC313461 (Engine) - C:D Session gets MSGCSP057E snode session could not start to intended route, and NullPointerException RTC314325 (Engine, - Unable to import Certificate with wrong Country Code CM) encoding into CM RTC314343 (Engine) - Out of memory error during C:D sessions ================================================================================ Summary of Fixes for SSP 3.4.0 Patch 1 Build 142 (October 2011) Full descriptions below. Fixes are marked as Engine, CM (Configuration Manager), and GUI (Admin GUI) ================================================================================ QC18890 (GUI) - Correct Sort by ID functionality QC18998 (Engine) - Display the user specified Login Banner if present QC19167 (Engine) - Error connecting to SSP SSH/SFTP proxy adapter with Axway client QC19343 (CM, GUI) - Disallow duplicate routing names for a key in the same key store QC19364 (Engine) - Unable to transfer files via FTP with specific key words in filename (e.g. "port") QC19425 (Engine,CM) - Ensure status of adapter is displayed correctly after failure QC19443 (Engine,CM) - Some internal connections fail when CM and engine configured for SSLv3 QC19521 (CM, GUI) - Unable to import some key certificates from Certificate Wizard. QC19557 (Engine) - Intermittent SFTP transfer failures due to rekey issue QC19579 (GUI) - Require selecting a local SSH key store before selecting a key from the store QC19604 (Engine) - SSP adding "?c=n" at the end of external URI redirection II. Detailed Description of Fixes =============================================================================== Detailed Descriptions of Fixes in (ascending fix order) Fixes are marked as Engine, CM (Configuration Manager), and GUI (Admin GUI) =============================================================================== QC18890 (GUI) - Correct Sort by ID functionality The Sort by Name functionality in the User Store was dropped in 3.3.01. Resolution: Corrected the User Store table element to allow sorting by Name QC18998 (Engine) - Display the user specified Login Banner if present The user specified Login Banner for an FTP adapter was not being displayed when the policy option was set to No Auth at SSP and Passthru to the backend. Resolution: Changed to always display the user specified Login Banner text if present, even when policy is set to No Auth and Passthru. QC19167 (Engine) - Error connecting to SSP SSH/SFTP proxy adapter with Axway client Remotes running a version of the Axway SSH/SFTP client were experiencing problems after connecting to the SSP SFTP adapter. The SFTP adapter was expecting the client to provide the SSH_FXP_REALPATH command before any other command after the SSH_FXP_INIT. The Axway client was not supplying the REALPATH command. Resolution: Updated the SFTP adapter to relax the requirement for the client to send the SSH_FXP_REALPATH command before any other command after the SSH_FXP_INIT is received at session startup. QC19343 (CM, GUI) - Disallow duplicate routing names for a key in the same key store The same Routing Name value was being allowed for multiple keys in the same SSH Local User Keystore. Resolution: Disallow duplicate routing names for a key in the same key store QC19364 (Engine) - Unable to transfer files via FTP with specific key words in filename When attempting to upload a file with the characters "PORT" or "PASV" imbedded in the filename using the FTP protocol, the operation gets rejected with message SSP170E Error PASV response from Server - 125 Data connection already open; transfer starting. Resolution: Updated the Command handler to only look at the beginning of the command buffer for the keywords "PASV" or "PORT". This allows filenames such as "STOR filename.PORT.txt" to be ignored. QC19425 (Engine,CM) - Ensure status of adapter is displayed correctly after failure When failover.detection.enabled = true in the adapter and the outbound server could not be reached, the adapter stopped listening on the inbound side. However, in some cases, the CM monitoring screen stayed "green", when it should have been "yellow". Resolution: Corrected code that starts and stops the listener ensuring that the status sent to CM matches the actual listener status. QC19443 (Engine,CM) - Some internal connections fail when CM and engine configured for SSLv3 After using configureCmSsl and configureEngineSsl scripts to change the security protocol to SSLv3, the GUI session can fail along with the secure connection to the engine. Resolution: Updated the SSPDashboard to push all SSL parameters that are used to connect to the CM server to the ConfigContent module so that all parts are in sync. QC19521 (CM, GUI) - Unable to import some key certificates from Certificate Wizard. Key certificates encrypted with a passphrase other than "password" could not be imported into the CM System Key Store. The null string was being used during the verification which caused the verification to fail. Resolution: Retrieve and use the user provided passphrase when verifying the keyCert. QC19557 (Engine) - Intermittent SFTP transfer failures due to rekey issue When transferring large files, the SFTP adapter occasionally failed with re-key issues. On the back-end SI, the following error indicated a re-key problem: An exception occurred in writeFile. java.io.IOException: seek 326713344 not supported with cursor 326610944. Resolution: Upgraded the maverick-all.jar (J2SSH) from 1.4.21 to 1.4.33. It includes a fix for intermittent file transfer failures due to re-key issues. QC19579 (GUI) - Require selecting a local SSH key store before selecting a key from the store In the SFTP outbound node configuration, CM allows not selecting the local user key store, but selecting a key. However when this happens, when CM pushes the configuration to engine, SSP Engine is unable to load the key and use it. Resolution: Require selecting a local SSH key store before selecting a key from the store QC19604 (Engine) - SSP adding "?c=n" at the end of external URI redirection SSP adding extra characters (such as ?c=5 or ?c=6) while redirecting to the URL specified in the External Application Login URL field of an SSO configuration. Resolution: Now only add this query parameter when it is being used for an internal portal. RTC140648 (Engine) - Correctly load the Step Permission values from the PNODE policy for each new CD session. A CD policy is pushed to the engine with Step Permissions:RunTasks set to true. The policy is successfully used by a process several times. Another process runs on the adapter using a netmap/policy with RunTasks set to false. When the first process runs again, it fails with CSP057E 16 Exception or other serious error occurred: exception in processing runtask policy prevents runtask from proceeding The CD configuration manager was not resetting policy defaults for Step Permissions at session start time. It only subtracted permissions when a policy used false values for RunTask, RunJob, Submit or Copy, causing the whole adapter to use false values until the policy is pushed again. Workaround: Ensure all polices you reference use a true value for the Step Permissions. Resolution: Corrected the CD Configuration manager to accurately load the Step Permission values from the PNODE policy for each new CD session. RTC140686 (Engine) - Tectia SSH sftpg3 command line client unable to connect to SSP When using the Tectia sftpg3 command line client to connect to an SSH adapter on SSP, the session terminates immediately after authentication. The logs show that the SSH_FXP_EXTENDED feature file-stat-extended@ssh.com was rejected: SSE2633 Closing remote client connection due to command decode policy: SSH_FXP_EXTENDED, version:3, Reason:invalid extended request: file-stat-extended@ssh.com request due to {1} request Per the SSP protocol, even though the feature is not supported, the session should not be terminated. Resolution: Updated the SSH command decoder to return a SSH_FXP_STATUS code rather than disconnecting the session. RTC140514 (Engine) - SFTP Adapter rejects sessions specifying SFTP protocol 5 or 6. SFTP Clients that connect specifying SFTP protocol version 5 or 6 are rejected by SSP, even if the client is capable of negotiating down to version 3. SSP logs the following messages and closes the connection: SSE2621 unsupported sftp protocol version:6 SSE2633 Closing remote client connection due to command decode policy: SSH_FXP_INIT, version:0, Reason:unsupported version:6 request due to {1} request One client that saw this failure was WinSCP. Resolution: Updated the SSH command decoder to allow the SSH_FXP_INIT specifying SFTP versions of 5 or 6, in addition to 3 and 4, which it already allows. It now returns a SSH_FXP_VERSION of 3 to allow the client to negotiate down rather than disconnecting the session. RTC140683 (Engine) - Secure+ Timeouts during download of large files Customer getting timeout messages when transferring large files with Connect:Direct Secure Plus through SSP. If the files take longer than 90 seconds to transfer, the Customer gets such messages as XIPT016I, XSMG621I, XCPS004I, and XSMG605I. The secureproxy log shows CSP900E Logged Exception : Did not get buffer in 90000 ms. A previous fix inserted a timeout on the channels that transfer data from PNODE to SNODE and from SNODE to PNODE. While data was traveling in one direction, the SSP channel that handled data going the other direction timed out waiting for data or an FMH, etc. Workaround is to increase the TCP timeout value in the Advanced tab of the Netmap for the C:D node(s). Resolution: Changed the code in the SSP C:D channels to ignore the timeout if the transfer is still running. RTC140524 (Engine) - CSP900E Logged Exception due to long PCRT value in C:D FMH70 A Connect:Direct Secure Plus session through SSP failed during the initial FMH exchange because the PCRT field added to the FMH70 record caused the zOS SNODE to mis-handle the record and drop the session. When the PCRT field is large, it can cause problems if the SNODE cannot handle the larger FMH70 RU. Study showed that the certificate passed in the PCRT field was not the PNODE certificate at all, which makes it of little value. Resolution: Turned off adding the “PCRT” breadcrumb to the C:D FMH70 unless the behavior is specifically turned on at the adapter level. The following properties are now the default in the C:D adapter: "CDSP|*|BreadCrumbAddress" = “granted” (allows “PRXY” breadcrumbs to be inserted) "CDSP|*|BreadCrumbAddressTransparentContent" = “granted” (allows more detail in “PRXY” field) "CDSP|*|BreadCrumbAddressPCRT" = "denied" (Do not insert the “PCRT” field) To continue to send the “PCRT” field, you must add the following property to the C:D adapter Properties tab of the CM GUI: "CDSP|*|BreadCrumbAddressPCRT" = "granted" RTC310391 (Engine) - SFTP connections fail when multiple authentication methods defined in netmap The Customer attempted to define password only authentication for one address in the SSH SFTP netmap and key only authentication for all others, like so: Name Peer Address Pattern Password_Inbound_SFTP 10.20.30.40/32 KeyOnly_Inbound_SFTP * However, no matter which address the remote logged in from, the server required both password and key authentication, so the authentication failed. Another variation of the problem is if the authentication method is first defined as password AND key, the authentication fails in the same way when dropped back to password OR key. This happens even with only one peer address pattern. Resolution: Updated the SFTP authentication selection code to first clear the authentication methods for the session and then add them per the values in the netmap. RTC311930 (Engine) - In FIPS mode, SSP log shows Invalid Key Strength: 512 Customer is running an outbound Connect:Direct Secure+ session with their keys stored in a HSM (Hardware Storage Manager) device. The transfers work ok until they turn on FIPS mode for the HSM device. Then the sessions fail with an exception in the log, “Invalid Key Strength: 512”. The HSM toolkit in the Java Security chain required the export key to be generated with a minimum key length of 1024 bits. Resolution: Added a new property in the C:D adapter to control the key size of the export key during C:D Secure Plus sessions. The “RsaExportKeySize” property will have a default of 512. To change the key size to 1024, define the property in the C:D adapter: RsaExportKeySize = 1024 RTC313461 (Engine) - C:D Session gets MSGCSP057E snode session could not start to intended route, and NullPointerException Customer is upgrading from SSP 2.x to SSP 3.4 and imported the configuration from SSP 2.x. When running Connect:Direct Secure+ sessions outbound through SSP, they get MSGCSP057E snode session could not start to intended route and a NullPointerException in ProxyServerCDImpl. Resolution: Corrected an error where a property was attempting to be pulled from a null configuration object. Now catch the error and continue processing. RTC314325 (Engine, - Unable to import Certificate with wrong Country Code CM) encoding into CM Customer attempted to import a certificate using the SSP Configuration Manager GUI and got message, Unable to parse certificate. Further research showed that the certificate was failing on the Country Code, because it had been generated with an ASN1 encoding of UTF8String instead of the required PrintableString. Resolution: Added a way for the Customer to ignore the check for Illegal encoding on the Country Codes by adding the -DallowIllegalCountryNameEncodings=1 parameter to the java parameters in the CM and engine startup scripts. RTC314343 (Engine) - Out of memory error during C:D sessions Customer applied fix RTC140683 for CD sessions and began to get Java Out of Memory errors within 24 hours. Fix RTC140683 did some cleanup on the session tracing, but introduced a problem where a trace buffer was never written and never cleared and grew to over 800MB. Resolution: Corrected the code that kept the trace buffer from being written and cleared. RTC319700 (Engine - PeSIT adapter) - PeSIT messages support and outbound PeSIT node trace have been added. RTC103849 (CM - Installation) - SSPCM will not start after upgrade if dfltKeyStore.xml file is missing The Customer had created a new System Certificate Store using the CM and deleted the one entitled dfltKeyStore. The Customer upgraded the CM, and the installation process laid down a new dfltKeyStore.xml file which was not encrypted. When the CM tried to decrypt the file to read it, the result was garbage and the CM failed to come up. The workaround was to delete the /conf/configurator/keyStore/dfltKeyStore.xml after the upgrade and start the CM. Resolution: Updated the SSP CM Installer to NOT lay down a fresh copy of the following files during an upgrade. The files will be added during a new install only. ./conf/configurator/keyStore/dfltCMTrustStore.xml ./conf/configurator/keyStore/dfltCMKeyStore.xml ./conf/configurator/keyStore/dfltKeyStore.xml ./conf/configurator/keyStore/dfltTrustStore.xml ./conf/configurator/pwdPolicy/defPasswordPolicy.xml ./conf/configurator/userStore/defUserStore.xml ./conf/system/defSslInfo.xml ./conf/system/defTrustStore.xml RTC288193 (CM GUI) - SSP UI tables not displayed under FireFox 9.0.1 Several GUI tables were not being displayed under FireFox 9.0.1. Resolution: Added corrected table logic to ensure the tables display. RTC315035 (Engine) - HTTP Header size rejected as too large The Customer attempted to override the HTTP Adapter property httpMaxHeaderFieldLength higher than the default value of 8192, but it always used the default. During sessions where the backend server used cookies which pushed the HTTP header length above 8192, the session would fail with SSP154E RequestHeader Line length >= max. length (8,192) Resolution: Corrected the HTTP adapter to correctly allow overrides to the default values of httpMaxHeaderFieldLength, httpMaxNumHeaderFields, html.rewrite.threads, and html.rewrite.threads.queue.size. RTC321975 (CM - Installation) - SSPCM will not start after upgrade from SSP 3.2 The Customer attempted to upgrade the CM from SSP 3.2 to SSP 3.4. The CM failed to come up and the cms.log contained WARN org.eclipse.jetty.util.log - Failed startup of context WebAppContext java.util.zip.ZipException: invalid entry size (expected 2343829512 but got 19513 bytes) * * * ERROR com.sterlingcommerce.hadrian.system.ServiceManagerImpl - Startup did not succeed. Terminating. Resolution: Updated the SSP CM Installer to remove the ./apps/jetty/webservices/webapps/SSPDashboard and SspJsf directories during the pre-install portion of an upgrade. The directories are repopulated during the install. RTC322562 (Engine) - FTP EPSV and EPRT commands not correctly handled in SSP When SSP encounters the EPSV (extended passive) or EPRT (extended port) commands from the client, it incorrectly forwards the command to the back end server and echoes the reply to the client. However, since the port that the back end server listens on is not the same as the port that SSP will listen on, the client is never able to connect to the data channnel. Resolution: Now reject the EPSV and EPRT FTP commands from a client and allow the client to retry with the PASV or PORT command. RTC322567 (Engine) - SSP aborts session if CDSA sends DSEQ in FM71 When sending a transfer from a Connect:Direct zOS via SSP, the following error message is displayed and the transmission is aborted: Exception or other serious error occurred: cvc-complex-type.2.4.a: Invalid content was found starting with element 'DSEQ'. One of '{SBXS, SBLX, DBXS, DBLX, SBFS, ..., etc, ... FRKP, DKYL}' is expected. The Customer has the Protocol Error Action is set to Abort in the SSP C:D Policy, which instructs SSP to validate the FMH and ensure that no invalid keys are passed to the outbound C:D image. The workaround is to set the Protocol Error Action to None, Ignore, or Warn. RTC330660 (CM, Engine) - Jetty PSIRT Advisory 258 - DOS Hashmap attack IBM PSIRT Advisory 258 was opened to document a denial of service attack on web servers that use a hashmap to store HTTP request headers. Resolution: Changed Jetty to limit the number of HTTP parameter keys in a request to a default of 1000. The value can be overridden by specifying -Dorg.eclipse.jetty.server.Request.maxFormKeys on the java startup line in the /bin/startEngine.sh or /bin/startCM.sh scripts. RTC336420/IC85514 (CM, Engine) - Loop getting "Fast wakeup condition detected" Customer gets loop in SSP logs showing the following messages. WARN com.sterlingcommerce.component.accepter.csap.impl.AccepterImpl - Fast wakeup condition detected. ERROR com.sterlingcommerce.component.accepter.csap.impl.AccepterImpl - Could not handle fast wakeup condition - java.lang.Error The bug is due to a Java error seen on IBM's HP and AIX JREs shipped with SSP. Resolution: Added code to correct the loop and provide better diagnostics when the socket accept error happens. Also updated the IBM JRE shipped with the SSP 3.4.1 server to be at the JRE 6 SR11 level. RTC336514/IC87275 (CM) - Duplicate SSH public key with different name in Authorized Keystore causes key authentication to fail If the administrator adds a duplicate SSH public key with a new name to the Authorized User keystore, the error is not found until the user connects and attempts to validate using the key. Depending on the order of the keys in the keystore, the connection may fail with: SSE2621 User key list was not empty and key UserKey2 was not in user key list SSE2610 Sessionid xxx Userkey xxx Invalid Logon Attempt, Count 1, ... SSE2624 Userid xxx from address xxx failed validation with key fingerprint xx:yy:zz Resolution: Added a search in the SSH Authorized User Keystore Configuration screen for a duplicate key fingerprint before saving a new key. If a duplicate key is found, a pop-up message is generated indicating which key it is a duplicate of so that the administrator can use that definition instead: Specified key finger print xx:yy:zz is already associated with authorized key UserKey2 RTC341834/IC85733 (Engine) - SFTP intermittently not returning the SSH server identification string during session startup When an SFTP client connects to the SSP SFTP adapter and already specifies an encryption method in its initial key exchange record, SSP does not return the server identification string as its first message to the client. Instead SSP responds with its own SSH key exchange (KEXINIT), which is out of order. The client software disconnects. Resolution: Updated the SSH toolkit, which contains the fix to ignore the encryption method if it appears in the first record at SFTP connection time. RTC347314/IC87274 (CM) - Admin able to add same named C:D node within netmap if name is in mixed case. Using the SSP configuration GUI for the CD netmap, the administrator is able to add a duplicate node using the same name if they use mixed case. Resolution: Now use a case-insensitive search for duplicate node names within the CD netmap before saving a new nodename. RTC347347/IC87266 (CM) - SFTP Post-Authentication Banner Text appears before client authentication SSP allows the administrator to supply a Pre-Authentication Banner Text and a Post-Authentication Banner Text in the SFTP adapter advanced tab. However, the pre-authentication banner never appears in a client session, and the post-authentication banner appears prior to the prompt for password on the client session. The banners are working as designed, but are named relative to server authentication, which comes before client authentication in an SSH session. The pre-authentication text allows the administrator to hide the SSH toolkit name, if desired. The post-server authentication text allows the site to display some legal verbiage on the client screen before they are fully authenticated. The names of the fields on the SFTP adapter advanced tab are updated to reflect the true use of the banners, and the help text will be updated accordingly. Resolution: Changed the names of the fields on the SFTP adapter advanced tab from "Pre-Authentication Banner Text" to "SSH Server Identification Text" And "Post-Authentication Banner Text" to "Post-Server Authentication Banner Text". RTC348461/IC86820 (CM, Engine) - SSP on Solaris using 32-bit version of JRE The Customer upgraded to SSP 3.3.01 on Solaris to get the 64-bit capability, but found that the JRE was only 32-bit. All the scripts to run the product and utilities point to the ./jre/bin/java executable, which is the 32-bit version of the JRE. The 64-bit version of the jre is at ./jre/bin/sparcv9/java. Workaround: Manually update the SSP/bin/startEngine.sh startCM.sh scripts to point to the new java location. However, these scripts get rebuilt during each maintenance upgrade. Resolution: Updated the InstallAnywhere logic for the Solaris platform to properly build the scripts to point to the 64-bit version of the JRE at ./jre/bin/sparcv9/java. RTC350243/IC87276 (CM) - Unable to stop CM with stopCM.sh and no indication why The Customer ran the stopCM.sh command, but the CM did not come down and no indication was given why. The utility prompted for the system passphrase, admin id and password, then ended with no message. The utility had a deficiency that if the admin userid/password was not correct, it silently ended. Resolution: Updated the shutdown logic in the utility to return better diagnostics in case of a connection failure or an authentication failure. Also, give positive feedback when the CM has successfully been told to shut down. RTC351025/IC87649 (CM, Engine) - SFTP adapter session limits enforced globally rather than at the adapter level. When multiple SFTP adapters are defined on one engine, each adapter uses the combined active session count of all adapters to determine if its session count is reached. For example if Adapter1 is defined with a max session count of 1 and Adapter2 is defined with a count of 3, if one session starts on Adapter2, no sessions may start on Adapter 1. Or if one session starts on Adapter1 and 2 sessions start on Adapter2, a third session will not start on Adapter2. Resolution: Updated the SSH toolkit, which contains the fix to correctly handle the session counts between adapters. RTC367002/IC90711 (CM) - CM Inadequate application error handling Security scan determined that the Sterling Secure Proxy Configuration Manager may return an error and a java stack trace to the browser when erroneous input data is entered. An attacker can exploit this to obtain information about the application to design further attacks. Resolution: Updated the SSP CM to catch errors and suppress the printing of stack traces to the browser so that it doesn't send unnecessary information to a would-be attacker. RTC367003/IC90712 (CM) - Version information revealed in HTTP header Security scan revealed that the version of the web server used by SSP CM is displayed in the HTTP header. This gives an attacker a head start in designing an attack specific to that web server version. Resolution: Updated the SSP CM web server parameters to no longer broadcast the version of the software in the HTTP headers. RTC367009/IC90714 (CM) - CM application pages do not break out of third party frames Security scan revealed that Sterling Secure Proxy Configuration Manager pages permit rendering within third party HTML frames. An internal attacker could potentially control elements of the framed pages and obtain unauthorized access to data. Resolution: Implemented frame options within the SSP CM web pages to keep third party applications from rendering the frames. RTC367240/IC90704 (CM) - Disable CM autocomplete of password field Security scan determined that the password field in the SSP Configuration Manager login page should not allow the browser to use the autocomplete function. Resolution: Corrrected the SSP CM Login page to set Autocomplete=false on the password field when the page is initialized. RTC368508/IC90590 (PS) - Perimeter Server fails to come up after SSP3416 install on Solaris Customer installed the SSP 3.4.1.6 (3.4.1.0 Patch 6) Perimeter Server on Solaris, which contained the fix for RTC348461, supporting the 64-bit JRE on Solaris. Afterward, the PS would not come up. The following messages were produced: Exception in thread "main" java.lang.NoClassDefFoundError: {LOG_FILE} Could not find the main class: {LOG_FILE}. Program will exit. The InstallAnywhere step which updates the startupPs.sh script incorrectly interpreted a large portion of the startup line as a local variable and eliminated it. The same problem is in the 3.4.0.6 version. Resolution: Updated the InstallAnywhere process to bypass interpreting local variables so that the startup line in the startupPs.sh script would remain intact on the Solaris platform.