Microcode Update for AL14SX
73/146/300/450/600 GB
15K RPM SAS Hard Disk Drive
Microcode Level 7108
DATE: December 8, 2022
Table of Contents
2.
AIX and VIOS(PowerVM Virtual I/O Server) Operating System
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.3 Transferring and
Unpacking the Microcode Update Package
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
===============================================================
The Microcode
files provided in this package are for SAS disk drives used in
Below is the list of microcode
files in this package:
NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction
Size |
Disk Drive Model |
FRU# |
P/N (VPD) |
Microcode File Name |
Checksum |
600GB |
AL14SXQ60EN |
00E8653 |
00LY482 |
AL14SXQ.A1800014.37313038 |
39627 |
00E8665 |
00LY524 |
||||
00E9914 |
00LY510 |
||||
02YC765 |
02YC757 |
||||
450GB |
AL14SXQ45EN |
44V4432 |
00LY498 |
||
300GB |
AL14SXQ30EN |
74Y6496 |
00LY481 |
||
74Y6498 |
00LY523 |
||||
00E9912 |
00LY509 |
||||
00LY429 |
00LY512 |
||||
10N7208 |
00LY497 |
||||
02YC764 |
02YC756 |
||||
03JG439 |
03JG438 |
||||
146GB |
AL14SXQ14EN |
00E6169 |
00LY480 |
||
00E6173 |
00LY522 |
||||
00FX876 |
00LY508 |
||||
10N7232 |
00LY496 |
||||
02YC761 |
02YC755 |
||||
73GB |
AL14SXQ07EN |
00E6168 |
00LY479 |
||
10N7230 |
00LY495 |
Release date |
Code level |
Impact/ Severity |
Change Description |
Dec. 2022 |
7108 |
Function/ ATT |
-Added PN/FRU's for new drive tray (Kapton tape
removal) |
June 2020 |
7106 |
Function/ ATT |
-Added
DS8K PN/FRU |
Feb 2019 |
7105 |
New/ New |
Initial Release |
===============================================================
Note: For VIOS systems,
microcode of shared physical I/O resources can only be updated from VIOS
partition.
To update disk drive
microcode, from VIOS partition, enter the following command:
oem_setup_env
Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code.
Approximately 20 minutes
if using Diagnostics CD; Approximately 5 minutes/drive using AIX concurrent
diagnostics.
2.2 Determine Drive Model,
FRU&PN and Current
Microcode Level
To see the drive type and current
microcode level, Execute the following command:
lscfg -vl hdisk* |pg ; For
drives NOT configured for RAID
lscfg –vl pdisk*
|pg ; For drives configured for RAID
Vital
Product Data (VPD)
hdisk2 U5887.001.G232002-P1-D2 SAS Disk Drive
(300000 MB)
Manufacturer................IBM
Machine Type and Model...... AL14SXQ30EN
FRU
Number..................74Y6496
ROS Level
and ID............ 37313038
Serial
Number...............xyz
EC
Level....................P02080
Part Number................. 00LY481
Device Specific.(Z0)........000006329F003002
Device Specific.(Z1)........10317108
Device Specific.(Z2)........0021
Device Specific.(Z3)........16183
Device Specific.(Z4)........
Device Specific.(Z5)........22
Device Specific.(Z6)........P02080
Hardware Location
Code......U5887.001.G232002-P1-D2
If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model” fields match the one listed in
section 1.1
Note:
Drive microcode level in “
===============================================================
a) Make a directory on an AIX
system to receive the AIX format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
You'll see the filename isAL14SX5xx.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x AL14SX5xx.bin
./AL14SX5xx.bin
[Don't overlook the periods (.) in the above command.]
The directory AL14SX5xx with microcode files listed in section 1.1 will be
added to /tmp/fwupdate.
d-Enter the following command to copy the microcode files to " /etc/microcode
" directory :
cp /tmp/fwupdate/ AL14SX5xx/AL14SX*
/etc/microcode
Note: The instructions that follow are specific
AIX commands. AIX commands are CASE (lower and upper) SENSITIVE,
and must
be entered exactly as shown, including filenames.
a) Make a directory on an
AIX system to receive the
Enter: mkdir
/tmp/microcode
b) Transfer the
You'll see the filename is AL14SX5xx–7108-AIX.rpm
c) Unpack the file by
executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos --force AL14SX5xx–7108-AIX.rpm ;(please note, there are two dashes)
The file size and checksum
will be verified.
The microcode files will be
added to /etc/microcode/
Copy microcode updates from
the CD-ROM to standard locations on your local disk:
1.
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as
this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files in
case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks;
however, as a precaution, ensure that a backup operation has been performed on
the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently? YES
Is system reboot needed to activate the microcode: Yes
if stand alone diagnostics CD is used, NO if concurrent diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone
diagnostics is used(using Diagnostics CD);
Approximately 5 minutes/drive if concurrent diagnostics is used.
2.4.1 Concurrent Download
1. Type diag
at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE***
The microcode installation occurs while the attached drives are
available for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to continue.
/etc/microcode
usb mass storage
- Use /etc/microcode
if "restore" command is used to copy files from diskette onto the
disk
- Use diskette if using diskette as the source for download
7- Display shows a list of microcodes
available for the selected drive, highlight option "M
AL14SXxx...", the latest microcode for the drive and press ENTER. A
message may warn you that current level of microcode is not available on the
media, press ENTER to continue.
8. You will receive a msg. "Current
Microcode is...." and "Download has completed successfully"
(this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.2 Standalone (Service Mode) Download
Use
similar steps as above when booting from a Diagnostics CD
======================================================
Microcode can be
updated using the iprconfig
utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to
update microcode is
selected, all available microcode levels are
presented to choose to download.
1. If using SLES 9 base, install the
package by typing:
rpm -ivh --ignoreos AL14SX5xx–7108-LINUX.rpm
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select Download
microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in Progress” with
elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the
"Firmware Version" field
--------------------------------------------------------------------------
Microcode can be
updated using the iprconfig
utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to
update microcode is
selected, all available microcode levels are
presented to choose to download.
1. tar -C-xzvf AL14SX5xx–7108-LINUX.tgz
iprconfig
Press Enter.
3. Select Download
microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in Progress” with
elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the "Firmware Version" field