IBM pSeries Servers
Microcode Update for KS5XX15KV6

73/146/300/450/600 GB
15K RPM SAS Hard Disk Drive
Microcode Level 861H

 

DATE: June 2, 2022



Table of Contents

1.   General Information

1.1 Disk Drives Affected

1.2 Microcode Change History

2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System

2.1 Installation Time

2.2 Determine Drive Model, FRU&PN and Current Microcode Level

2.3.1 Internet AIX self extracting file (.bin)

2.3.2 Internet RPM package

2.3.3 CD-ROM

2.4 Microcode Download Procedure

3.   Linux Operating System

3.1 ReadHat (RHEL) and SLES

3.2 Ubuntu

4.   Revisions

===============================================================

1.   General Information

The Microcode files provided in this package are for SAS disk drives used in IBM system P Servers

with AIX or Linux operating systems

1.1 Disk Drives Affected 

Below is the list of microcode files in this package:

NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction

 

 

Size

Disk Drive Model         

FRU#

P/N (VPD)     

Microcode File Name                         

Checksum

600GB

ST600MP0016

00E8653

00LY478

ST600MP.A1800012.38363148

42881

00E8665

00LY521

00E9914

00LY507

450GB

ST600MP0016

44V4432

00LY494

ST300MP.A1800012.38363148

300GB

ST300MP0016

74Y6496

00LY477

74Y6498

00LY520

00E9912

00LY506

00LY429

00LY511

10N7208

00LY493

02YC612

02YC610

146GB

00E6169

00LY476

00E6173

00LY519

00FX876

00LY505

10N7232

00LY492

73GB

00E6168

00LY475

10N7230

00LY491

 

1.2 Microcode Change History

Release date

Code level

Impact/

Severity

Change Description

June 2022

861H

Function/

ATT

Command Timeout observed on a few Diagnostic commands which typically take longer time to execute.
Diagnostic Commands which typically take longer to execute have to be excluded from Overall Command Timeout.
Added the Diagnostic Command CDB's to OCT Exclude list so that commands which typically take longer won't be aborted by OCT limit exceeding.

Dec 2021

861G

Function/

ATT

-This level of microcode is required to support new NAND component; the change is in controller FW.

-Other fixes and enhancements

April 2021

861E

Function/

ATT

- Drive become unresponsive during write same command processing
- Drive become unresponsive following hard reset during write command
-  Single SAS port become unresponsive

May 2020

861B

Serviceability/

ATT

FW change is made for IBM MFG to support new PN.

No functional change in this code

Sept 2019

861A

Function/

ATT

-Fixed a fw bug that causes drive to fail when there are too many back-to-back “skip” commands, this only affects raid member drives only (pdisk), not JBOD (hdisk)

-Other fixes and enhancements

Nov 2018

8619

Performance/

ATT

Performance Improvement (Improved random read with q-depth=1)

June 2018

8618

New/

New

Initial Release

 

===============================================================

2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System

Note: For VIOS systems, microcode of shared physical I/O resources can only be updated from VIOS partition.

To update disk drive microcode, from VIOS partition, enter the following command:     

oem_setup_env   

Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code.

2.1 Installation Time

Approximately 20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX concurrent diagnostics.
 

2.2 Determine Drive Model, FRU&PN and Current Microcode Level
To see the drive type and current microcode level, Execute the following command:
lscfg -vl hdisk* |pg      ; For drives NOT configured for RAID

lscfgvl pdisk* |pg     ; For drives configured for RAID

 

   Vital Product Data (VPD)

  hdisk2           U5887.001.G232002-P1-D2  SAS Disk Drive (300000 MB)

 

        Manufacturer................IBM

        Machine Type and Model......ST300MP0016

        FRU Number..................74Y6496

        ROS Level and ID............38363148

        Serial Number...............SAE00K23

        EC Level....................P02080

        Part Number.................00LY477

        Device Specific.(Z0)........000006329F003002

        Device Specific.(Z1)........1031861H

        Device Specific.(Z2)........0021

        Device Specific.(Z3)........16183

        Device Specific.(Z4)........

        Device Specific.(Z5)........22

        Device Specific.(Z6)........P02080

        Hardware Location Code......U5887.001.G232002-P1-D2

 

 

If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model”  fields match the one listed in section 1.1 AND the "ROS Level and ID...." field of that data is below "38363148", this microcode applies.

Note: Drive microcode level in “ROS Level and ID …” field is displayed in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character converts to a 2-digit hex number. For example in VPD displayed above, 38 Hex= ASCII character "8";  36 Hex= ASCII character "6"; 31 Hex=ASCII character "1"; 48 Hex=ASCII character "H",  microcode level is "861H ". Also note that the microcode level "861H " is displayed in “Z1” field.

===============================================================

2.3 Transferring and Unpacking the Microcode Update Package

2.3.1 Internet AIX self extracting file (.bin)

a) Make a directory on an AIX system to receive the AIX format file.
    Enter:      mkdir /tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
    You'll see the filename is KS5XX15KV6.bin
c) Unpack the file by executing the instructions below.
  Enter the commands:
  cd /tmp/fwupdate
  chmod +x KS5XX15KV6.bin
  ./ KS5XX15KV6.bin
[Don't overlook the periods (.) in the above command.]

The directory KS5XX15KV6 with microcode files listed in section 1.1 will be added to /tmp/fwupdate.
 

d-Enter the following command to copy the microcode files to " /etc/microcode " directory :
   cp /tmp/fwupdate/ KS5XX15KV6/ST9*  /etc/microcode

e- If you are using stand alone AIX diag (bootable USB flash or CD/DVD) to update drive’s microcode, transfer microcode files to a USB drive and place it in “/etc/microcode” directory.
    Please refer to this page for USB flash drive usage  
   
https://www.ibm.com/support/pages/using-and-taking-advantage-usb-devices-and-aix

2.3.2 Internet RPM package

Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE,

and must be entered exactly as shown, including filenames.

a) Make a directory on an AIX system to receive the RPM format file.
    Enter:      mkdir /tmp/microcode

b) Transfer the RPM format file to the /tmp/microcode directory.
    You'll see the filename is KS5XX15KV6–861H-AIX.rpm

c) Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihv --ignoreos  --force KS5XX15KV6–861H-AIX.rpm   ;(please note, there are two dashes)

The file size and checksum will be verified.

The microcode files will be added to /etc/microcode/
 

2.3.3 CD-ROM

Copy microcode updates from the CD-ROM to standard locations on your local disk:

1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode

Notes:
 - "/etc/microcode"  is a symbolic link to   "/usr/lib/microcode".
 - If permission does not allow the copy to the above stated directory
   or file then the user will be prompted for a new location.
========================================================

2.4 Microcode Download Procedure

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?  YES
Is system reboot needed to activate the microcode: Yes if stand alone diagnostics CD is used, NO if concurrent diagnostics is used.

Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if concurrent diagnostics is used.

2.4.1.2.1 Concurrent Download

1. Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then press "F7" to commit..
5- A small screen displays the message " *** NOTICE***  The microcode installation occurs while the attached drives are available for use..... "
    Press enter to continue
6.  Select the source for microcode, use arrow key to go up/down, Enter to continue.
                      /etc/microcode
                      diskette

   - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk
   - Use diskette if using diskette as the source for download

NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above).  Insert the diskette and press ENTER

7- Display shows a list of microcodes available for the selected drive, highlight option "M  ST9xx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue.

8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).

2.4.1.2.2 Standalone (Service Mode) Download

This procedure is used for all drives including rootvg or paging space drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above;  It is recommended to use the same level
    of  Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]
    Microcode level to download -----------------------------[ latest]
    Download latest level even if -----------------------------[ yes]
    current is missing

NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive.  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.

                             

======================================================

3.   Linux Operating System

 

3.1 ReadHat (RHEL) and SLES

 

Microcode can be updated using the iprconfig utility. The iprconfig utility

allows for multiple levels of adapter and device microcode to exist on the

system at the same time. After the device to update microcode is

selected, all available microcode levels are presented to choose to download.

 

1.  If using SLES 9 base, install the package by typing:

         rpm -ivh --ignoreos KS5XX15KV6–861H-LINUX.rpm

2. Update the microcode by typing:

                                 iprconfig

    Press Enter.

3. Select Download microcode and press Enter.

4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected.

5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter.

6. Press Enter again to confirm the download (display shows “Microcode Download in Progress” with elapsed time)

7. If multiple devices were selected, repeat from Step 5 for the next device.

 

To check the microcode level:

 

1. Start iprconfig utility,

2. Select "Display hardware status" option.

3. Select disk to query by typing a 1 next to it and pressing "Enter"

4. Look at the "Firmware Version" field

 

 

--------------------------------------------------------------------------

3.2 Ubuntu

 

Microcode can be updated using the iprconfig utility. The iprconfig utility

allows for multiple levels of adapter and device microcode to exist on the

system at the same time. After the device to update microcode is

selected, all available microcode levels are presented to choose to download.

 

1.  tar -C-xzvf KS5XX15KV6–861H-LINUX.tgz

2. Update the microcode by typing:

                                 iprconfig

    Press Enter.

3. Select Download microcode and press Enter.

4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected.

5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter.

6. Press Enter again to confirm the download (display shows “Microcode Download in Progress” with elapsed time)

7. If multiple devices were selected, repeat from Step 5 for the next device.

 

To check the microcode level:

1. Start iprconfig utility,

2. Select "Display hardware status" option.

3. Select disk to query by typing a 1 next to it and pressing "Enter"

4. Look at the "Firmware Version" field

 

 

4.   Revisions