IBM pSeries Servers - Microcode Update for Ultrastar 146LZX 9/18/36/73/146 GB   IBM pSeries Servers Microcode Update for Ultrastar SS300 400/800/1600 GB SAS Solid State Drive Microcode Level B16D   DATE: August 12, 2019 Table of Contents 1.      General Information 1.2     Disk Drives Affected 1.2 Microcode Change History 2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System 2.1 Installation Time 2.2 Determine Drive Model, FRU&PN and Current Microcode Level 2.3.1 Internet AIX self extracting file (.bin) 2.3.2 Internet RPM package 2.3.3 CD-ROM 2.4 Microcode Download Procedure 3.   Linux Operating System 3.1 ReadHat (RHEL) and SLES 3.2 Ubuntu =============================================================== 1.  General Information The Microcode files provided in this package are for SAS disk drives used in IBM system P Servers with AIX or Linux operating systems 1.2   Disk Drives Affected  Below is the list of microcode files in this package: NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction     Size Disk Drive Model FRU# P/N (VPD) Microcode File Name Check sum 1.6TB HUSMM3216ASS20 00LY623 00LY617 HUSMM32.A1800011.42313644 35764 00LY605 00LY599 01LU619 01LU617 800GB HUSMM3280ASS20 00LY578 00LY574 01LU623 00LY586 01LU616 01LU612 00LY604 00LY598 00LY622 00LY616 400GB HUSMM3240ASS20 00LY577 00LY573 00LY589 00LY585 01LU615 01LU611 00LY603 00LY597 00LY621 00LY615   1.2 Microcode Change History Release date Code level Severity/ Impact Change Description AUG 2019 B16D Usability/ ATT This code has a change that only affects IBM MFG process, it does not have any functional change affecting users Oct 2018 B16A Function/ ATT - Fixed Low Function Backplane, also called ?Base Function Backplane? hotplug  issue. With previous microcode B134 when drive is replaced new drive will not configure. Jan 2018 B134 Function/ ATT FW change to correct Log Page 34 (SMART) reporting of Unused reserve block count Dec 2017 B133 New/New Initial Release     =============================================================== 2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System Note: For VIOS systems, microcode of shared physical I/O resources can only be updated from VIOS partition. To update disk drive microcode, from VIOS partition, enter the following command:      oem_setup_env    Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code. 2.1 Installation Time Approximately 20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX concurrent diagnostics.   2.2 Determine Drive Model, FRU&PN and Current Microcode Level To see the drive type and current microcode level, Execute the following command: lscfg -vl hdisk* |pg      ; For drives NOT configured for RAID lscfg ?vl pdisk* |pg     ; For drives configured for RAID    Vital Product Data (VPD) pdisk0           U5887.001.G5CT01E-P1-D1  Physical SAS Solid State Drive           Manufacturer................IBM         Machine Type and Model......HUSMM3280ASS201         FRU Number..................01LU623         ROS Level and ID............42313644         Serial Number...............41V05T9X         EC Level....................P02081         Part Number.................00LY586         Device Specific.(Z0)........000006329F003002         Device Specific.(Z1)........BCIPB16D         Device Specific.(Z2)........0068         Device Specific.(Z3)........17061         Device Specific.(Z4)........         Device Specific.(Z5)........22         Device Specific.(Z6)........P02081         Hardware Location Code......U5887.001.G5CT01E-P1-D1 If the data returned in the ?Part Number?, ?FRU Number?, and ?Machine Type and Model?  fields match the one listed in section 1.1 AND the "ROS Level and ID...." field of that data is below "42313641", this microcode applies. Note: Drive microcode level in ?ROS Level and ID ?? field is displayed in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character converts to a 2-digit hex number. For example in VPD displayed above, 42 Hex= ASCII character "B"; 31 Hex= ASCII character "1"; 36 Hex=ASCII character "6"; 44 Hex=ASCII character "D",  microcode level is "B16D ". Also note that the microcode level "B16D" is displayed in ?Z1? field. =============================================================== 2.3 Transferring and Unpacking the Microcode Update Package 2.3.1 Internet AIX self extracting file (.bin) a) Make a directory on an AIX system to receive the AIX format file.     Enter:      mkdir /tmp/fwupdate b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").     You'll see the filename is SSD3200.bin c) Unpack the file by executing the instructions below.   Enter the commands:   cd /tmp/fwupdate   chmod +x SSD3200.bin   ./SSD3200.bin [Don't overlook the periods (.) in the above command.] The directory SSD3200 with microcode files listed in section 1.1 will be added to /tmp/fwupdate.   d-Enter the following command to copy the microcode files to " /etc/microcode " directory :    cp /tmp/fwupdate/ SSD3200/HUS*  /etc/microcode 2.3.2 Internet RPM package Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames. a) Make a directory on an AIX system to receive the RPM format file.     Enter:      mkdir /tmp/microcode b) Transfer the RPM format file to the /tmp/microcode directory.     You'll see the filename is SSD3200-B16D-AIX.rpm c) Unpack the file by executing the instructions below:     Enter the commands:         rpm -ihv --ignoreos  --force SSD3200-B16D-AIX.rpm   ;(please note, there are two dashes) The file size and checksum will be verified. The microcode files will be added to /etc/microcode/   2.3.3 CD-ROM Copy microcode updates from the CD-ROM to standard locations on your local disk: 1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM" 2. Microcode files will be copied to /usr/lib/microcode Notes:  - "/etc/microcode"  is a symbolic link to   "/usr/lib/microcode".  - If permission does not allow the copy to the above stated directory    or file then the user will be prompted for a new location. ======================================================== 2.4 Microcode Download Procedure Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive NOTE: Please save current and older versions of the microcode update files in case you need to restore your system. Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation. Can microcode be installed Concurrently?  YES Is system reboot needed to activate the microcode: Yes if stand alone diagnostics CD is used, NO if concurrent diagnostics is used. Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if concurrent diagnostics is used. 2.4.1.2.1 Concurrent Download 1. Type diag at the prompt. 2. Select the "Task Selection" from diagnostics menu. 3. Select "Microcode Download" from "Task Selection" menu. 4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then press "F7" to commit.. 5- A small screen displays the message " *** NOTICE***  The microcode installation occurs while the attached drives are available for use..... "     Press enter to continue 6.  Select the source for microcode, use arrow key to go up/down, Enter to continue.                       /etc/microcode                       diskette    - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk    - Use diskette if using diskette as the source for download NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above).  Insert the diskette and press ENTER 7- Display shows a list of microcodes available for the selected drive, highlight option"M  HUSxx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue. 8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"        (this may take a few minutes) 9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode. 10. Exit diagnostic(and reboot if needed). 2.4.1.2.2 Standalone (Service Mode) Download This procedure is used for all drives including rootvg or paging space drives 1. Properly shutdown the system. 2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above;  It is recommended to use the same level     of  Diagnostic CD as the AIX ). 3. Select the "Task Selection" from diagnostics menu. 4. Select "Microcode Download" from "Task Selection" menu. 5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER. 6. Press "F7" to commit.       (The current microcode level of the resource you selected earlier will be displayed at the top of the screen) 7. Make the following selections on the next screen:     Select Input Device --------------------------------------- [ diskette]     Microcode level to download -----------------------------[ latest]     Download latest level even if -----------------------------[ yes]     current is missing NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive.  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download. PRESS "F7" to commit 8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"        (this may take a few minutes) 9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode. 10. Exit diagnostic and reboot system in normal mode.                               ====================================================== 3.   Linux Operating System   3.1 ReadHat (RHEL) and SLES   Microcode can be updated using the iprconfig utility. The iprconfig utility allows for multiple levels of adapter and device microcode to exist on the system at the same time. After the device to update microcode is selected, all available microcode levels are presented to choose to download.   1.  If using SLES 9 base, install the package by typing:          rpm -ivh --ignoreos SSD3200-B16D-LINUX.rpm 2. Update the microcode by typing:                                iprconfig     Press Enter. 3. Select Download microcode and press Enter. 4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected. 5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter. 6. Press Enter again to confirm the download (display shows ?Microcode Download in Progress? with elapsed time) 7. If multiple devices were selected, repeat from Step 5 for the next device.   To check the microcode level:   1. Start iprconfig utility, 2. Select "Display hardware status" option. 3. Select disk to query by typing a 1 next to it and pressing "Enter" 4. Look at the "Firmware Version" field     -------------------------------------------------------------------------- 3.2 Ubuntu   Microcode can be updated using the iprconfig utility. The iprconfig utility allows for multiple levels of adapter and device microcode to exist on the system at the same time. After the device to update microcode is selected, all available microcode levels are presented to choose to download.   1.  tar -C-xzvf SSD3200-B16D-LINUX.tgz 2. Update the microcode by typing:                                iprconfig     Press Enter. 3. Select Download microcode and press Enter. 4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected. 5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter. 6. Press Enter again to confirm the download (display shows ?Microcode Download in Progress? with elapsed time) 7. If multiple devices were selected, repeat from Step 5 for the next device.   To check the microcode level: 1. Start iprconfig utility, 2. Select "Display hardware status" option. 3. Select disk to query by typing a 1 next to it and pressing "Enter" 4. Look at the "Firmware Version" field