IBM Power Systems
SAS Enclosure Services for 9009-41A/42A, 9223-42H
Feature Code EJ1D, EJ1M
Microcode Update
DATE: March 12, 2018
Table of Contents
2.0 General Information
2.1 Installation Time
2.2 Machine's Affected
2.3 AIX Requirements
2.4 Linux Requirements
3.0 Determine the Current Microcode Level for AIX
3.1 Determine the Current Microcode Level for Linux
4.0 Downloading and Unpacking the Firmware Update Package from CORE
4.1 Downloading the RPM Format File to the Target Server
4.2 Discovery Tool Microcode CD-ROM creation and download
instructions
5.0 Verifying microcode before download and notes
5.1 Microcode Download Procedure-SAS Enclosure Services for
AIX
5.2 Microcode Download Procedure-SAS Enclosure Services for
Linux
5.3 Microcode Download Procedure-SAS Enclosure Services for VIOS
6.0 Microcode Readme Change History
=====================================================================================
0140 |
Impact = NEW
Severity = NEW -GA Level |
This subject microcode is to be used on the following SAS expander (SES) type:
Power 9 4U High Function DASD backplane 9009-41A, 9009-42A, 9223-42H
FC:
EJ1D, CCIN 2D35
FC: EJ1M, CCIN 6B64
2.1 Installation
Time:
Approximately 30 minutes
2.2 Machine's
Affected:
9009-41A, 9009-42A, 9223-42H
2.3 AIX
Requirements:
For support:
6.1 TL9 SP11 (AIX 6.1 service extension required)
7.1 TL5 SP2
7.2 TL2 SP2
VIOS 2.2.3.5
or above
For support:
Red Hat Enterprise Linux 7.4, big endian, for POWER
Red Hat Enterprise Linux 7.4, little endian, for POWER
SLES
11 SP4 for POWER
Ubuntu 16.04.2 LE LTS
or above
3.0 Determine the Current Microcode Level for AIX:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SES installed in the system by typing:
lsdev -C | grep ses
Note: All of the SAS RAID initiators addresses that are installed will be displayed. The names will be sesX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl sesX
Where X is the number/s of the previous command. The Command will produce output similar to
Example shown for FC EJ1D, CCIN 2D35
DEVICE LOCATION DESCRIPTION
# lscfg -vl ses1
ses1 U78D2.001.WZS000E-P2-Y1 SAS Enclosure Services Device
SAS Expander:
FRU Number..................01DH407
Serial Number...............Y130UF73Y002
Customer Card ID Number.....2D35
Load ID.....................A1700DF6
ROM Level.(alterable).......0140
Hardware Location
Code......U78D2.001.WZS000E-P2-Y1
If the ROM Level is less than 0140 then you should update
the microcode.
3.1 Determine the
Current Microcode Level for Linux:
1) Type "iprconfig"
2) Select "Display hardware status"
3) Select SES by typing a "1" in front of it and pressing Enter.
4) The Command will produce output similar to
"Firmware Version . . . . . . . . . . . . : 0140"
If the Firmware Version is less than 0140 then you should update the microcode.
4.0 Downloading and Unpacking the Firmware Update Package from CORE
NOTE:
The CORE image will now be the RPM Format File.
1) After downloading the files from CORE on to your personal system find the
following files in the CORE destination directory (c:\ibmdocs\DISKIMG):
A) "ses-0140-1.aix6.1.noarch.rpm"
B) "ses-0140-1.Linux.noarch.rpm"
C) "ses-0140-1.Linux.noarch.tgz"
2) Log in to the Target Server
3) Create a directory, if not already existent (mkdir
/tmp/microcode; mkdir /tmp/microcode/RPM)
4) Transfer the file to the Target Server "/tmp/microcode/RPM
directory" using ftp or another method. Change to that directory,
"cd /tmp/microcode/RPM".
5a) For AIX: Unpack the RPM file by using the following
command: "rpm -ihv --ignoreos --force ses-0140-1.aix6.1.noarch.rpm"
5b) For Linux - RHEL/SUSE: Unpack the RPM file by using the
following command: "rpm -ihv --ignoreos --force ses-0140-1.Linux.noarch.rpm"
5c) For Linux - Ubuntu: Un-tar the file by using the following
command: " tar -C / -xzf ses-0140-1.Linux.noarch.tgz"
6a)
For AIX: The microcode files will be added to /usr/lib/microcode/.
6b) For Linux: The microcode files will be added to
/lib/firmware/.
6c) For the Linux - Ubuntu file: The microcode
files will be added to /lib/firmware/.
4.1 Downloading
the RPM Format File to the Target Server
Use this method to download to an AIX or Linux system:
Note: The instructions that follow are specific AIX/Linux commands. AIX/Linux commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1) Make a directory on an AIX/Linux system to receive the RPM format file.
Enter: "mkdir /tmp/microcode"
Enter: "mkdir /tmp/microcode/RPM"
2) Transfer the RPM format file to the /tmp/microcode/RPM
directory (using "Save as ..."). Change to that directory,
"cd /tmp/microcode/RPM".
You'll
see the filenames for the RPM files.
A) For AIX: The filename is ses-0140-1.aix6.1.noarch.rpm
B) For Linux - RHEL/SUSE: The filename is ses-0140-1.Linux.noarch.rpm
C) For Linux- Ubuntu: The filename is ses-0140-1.Linux.noarch.tgz
3)
Unpack the file by executing the instructions below:
A) For AIX: Type "rpm -ihv --ignoreos --force
ses-0140-1.aix6.1.noarch.rpm"
B) For Linux R- HEL/SUSE: Type "rpm
-ihv --ignoreos --force
ses-0140-1.Linux.noarch.rpm"
C) For Linux - Ubuntu: Un-tar the file by using the
following command: tar -C / -xzf ses-0140-1.Linux.noarch.tgz”
4a)
For AIX rpm file: The microcode files will be added to /usr/lib/microcode/.
4b) For Linux rpm file: The microcode files will be added to
/lib/firmware/.
4c) For the Linux - Ubuntu file: The microcode
files will be added to /lib/firmware/.
4.2 Discovery Tool Microcode CD-ROM creation and download instructions
To
obtain information how to burn a CD-ROM and run the Discovery Tool for an AIX
System please go to: http://techsupport.services.ibm.com/server/mdownload/CDROMhelp.html
1) After running the Discovery Tool successfully the "/tmp/microcode/RPM"
directory was created and your rpm files are copied from the CD-ROM.
2) Change to that directory, "cd /tmp/microcode/RPM".
3)
Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos --force ses-0140-1.aix6.1.noarch.rpm
4) Microcode files will be copied to "/etc/microcode". The file
size and checksum of the microcode image will be verified in Section 5.0
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
5.0 Verifying microcode before download and notes
NOTE:
Microcode download must be performed separately for each "ses" under distinct Logical Partitions (LPAR's).
Please save current and older versions of the microcode update files in case
you need to restore your system.
NOTE: Microcode update cannot
be performed to both SAS expanders (SES) at the same time.
Installation Time: Approximately 30 min System Time.
Please
verify the file size and checksum of the raw microcode files matches the below.
Filesize: 571648
Checksum: 30978
For AIX: "ls -l /usr/lib/microcode/
A1700DF6.0140" to verify Filesize.
"sum /usr/lib/microcode/A1700DF6.0140
" to verify Checksum.
For Linux: "ls -l /lib/firmware/A1700DF6.0140 " to verify Filesize.
"sum /lib/firmware/A1700DF6.0140 " to verify Checksum.
For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SES device in order to update the code. Follow this procedure for each partition:
For
AIX:
A) Log into the target
partition.
B) Type: "cd /usr/lib/microcode"
C) FTP (for AIX) or SFTP (for
Linux) to the partition that has the media bay assigned. (ie. ftp/sftp
partition1.ibm.com)
D) Type: "cd /usr/lib/microcode"
E) If using FTP then Type: "bin"
F) Type: "get A1700DF6.0140 "
G) Type: "quit"
For
Linux:
A) Log into the target
partition.
B) Type: "cd /lib/firmware"
C) SFTP to the partition that
has the media bay assigned. (ie.
"sftp
partition1.ibm.com")
D) Type: "cd /lib/firmware"
E) Type: "get A1700DF6.0140 "
F) Type: "quit"
5.1 Microcode Download Procedure-SAS Enclosure Services for AIX
Procedure:
1) It is advised, but not necessary to stop all applications.
2) Enter diag
3) Select the "Task Selection" from diagnostics menu.
4) Select "Download Microcode" or "Microcode Tasks ->
Download Microcode" from "Task Selection" menu.
5) Select all of the SAS Enclosure Services that need to be updated from the
list of devices by pressing "Enter". The devices will be
displayed as ses#, where #
is the number of the device. Press "F7".
6) A dialogue box will be displayed on screen. Press "Enter" to
continue.
7) Select "/usr/lib/microcode".
8) A dialogue box may be displayed on screen. It will state that the current
microcode level on the device is not in the /usr/lib/microcode
directory. This is acceptable as you will be flashing new microcode onto
the device. Also, incorrect code will automatically be rejected.
Press "Enter" to continue.
9) An "M" will be displayed next to the latest level of microcode in
the /usr/lib/microcode directory. Select that
level and press "Enter".
10) The following message will appear on the screen when download is completed:
"Microcode download complete successfully. The current microcode
level for the device ses# is
..... Please run diagnostics on the adapter to ensure that it is
functioning properly." DO NOT run diagnostics on the device at this
time.
In the case where multiple devices have been selected for update, if more than
one device has been selected, diagnostics will continue to the next device
update, and the option to return to the main menu to select running diagnostics
on the device that has just been updated will not be available until all the
devices have been updated.
11) Exit diagnostics.
12) Verify the code level is 0140 by typing "lscfg
-vl ses#"
for each SES device updated. <Where # is the number ses device>
5.2 Microcode
Download Procedure-SAS Enclosure Services for Linux
Procedure:
1) Stop all applications.
2) Type "iprconfig" and press
"Enter".
3) Select "Download Microcode" and press "Enter".
4) Select all of the SAS Enclosure Services that need to be updated from the
list of devices by pressing "1". Then press "Enter".
5) Select the appropriate microcode image to flash by pressing
"1". (The image will end in 0140). Press Enter.
Press Enter again to confirm.
6) If multiple devices were selected in step 4, then repeat step 5 until
finished.
5.3 Microcode Download Procedure-SAS Enclosure Services for VIOS
Procedure:
1) It is advised, but not necessary to stop all applications.
2) Enter diagmenu
3) Select the "Task Selection" from diagnostics menu.
4) Select "Download Microcode" or "Microcode Tasks ->
Download Microcode" from "Task Selection" menu.
5)
Select all of the SAS Enclosure Services that need to be updated from the list
of devices by pressing "Enter". The devices will be displayed
as ses#, where # is the
number of the device. Press "F7".
6) A dialogue box will be displayed on screen. Press "Enter" to
continue.
7) Select "/usr/lib/microcode".
8) A dialogue box may be displayed on screen. It will state that the
current microcode level on the device is not in the /usr/lib/microcode
directory. This is acceptable as you will be flashing new microcode onto
the device. Also, incorrect code will automatically be rejected.
Press "Enter" to continue.
9) An "M" will be displayed next to the latest level of microcode in
the /usr/lib/microcode directory. Select that
level and press "Enter".
10) The following message will appear on the screen when download is completed:
"Microcode download complete successfully. The current microcode
level for the device ses# is
..... Please run diagnostics on the adapter to ensure that it is
functioning properly." DO NOT run diagnostics on the device at this
time.
In the case where multiple devices have been selected for update, if more than
one device has been selected, diagnostics will continue to the next device
update, and the option to return to the main menu to select running diagnostics
on the device that has just been updated will not be available until all the
devices have been updated.
11) Exit diagnostics.
12) Verify the code level is 0140 by typing "lscfg
-vl ses#"
for each SES device updated. <Where # is the number ses device>
6.0 Microcode
Readme Change History
2018-03-12 |
-Initial Release |
|
|