IBM
pSeries Servers
Microcode Update for UltraStar
C10K1800 1800GB
Model:
HUC1018xxCS420
2.5”
SAS Hard Disk Drive
Microcode Level NAR1
DATE: July 28, 2017
Table of Contents
2. AIX and VIOS
(PowerVM Virtual I/O Server)
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
===============================================================
The Microcode files provided in this package are for SAS disk
drives used in IBM Power Systems AIX/Linux.
Below is the list of microcode files in this
package:
NOTE: To insure the integrity of microcode
files, please make sure the checksum value is correct after extraction
Size Disk Drive Model
FRU# P/N (VPD) Microcode File Name Checksum
-------- ----------------------- ----------- ------------ ----------------------------------- -----------
1800GB HUC101818CS420 00E9962 00E9958 HUC1018.A1800005.4E415231 63418
1800GB HUC101818CS420 00E9946 00E9942 “
“
1200GB HUC101812CS420
00E9961 00E9957 “ “
1200GB HUC101812CS420
00E9945 00E9941 “ “
600GB HUC101860CS420
00E9959 00E9955 “ “
600GB HUC101860CS420
00E9943 00E9939 “ “
1.2 Microcode
Change History
Release date |
Code level |
Impact/ATT |
Change Description |
July 2017 |
NAR1 |
Availability/ |
-Support new SMART attribute for smear
detection |
May 2016 |
N990 |
|
Added new PN, no
functional changes |
June 2015 |
N72A |
|
Initial Release |
===============================================================
Note: For VIOS systems, microcode of shared physical I/O
resources can only be updated from VIOS partition.
To update disk drive microcode, from VIOS partition, enter
the following command:
oem_setup_env
Then follow the instruction in section 2.3 to
transfer/extract the microcode file, and section 2.4.1 to update the disk drive
code.
Approximately
20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX
concurrent diagnostics.
2.2 Determine Drive Model, FRU&PN and Current Microcode
Level
To see the drive type and current microcode level, Execute the following
command:
lscfg -vl hdisk* |pg ; For
drives NOT configured for RAID
lscfg –vl pdisk*
|pg ; For drives configured for RAID
Example:
DEVICE LOCATION
DESCRIPTION
hdisk5
U5887.001.G17X00G-P1-D6 SAS 4K
Disk Drive (1200000 MB)
Manufacturer................IBM
Machine Type and
Model......HUC101812CS420
FRU Number..................00E9945
ROS Level and
ID............ 4E415231
Serial Number...............06G0L27H
EC Level....................N46243
Part Number.................00E9941
Device Specific.(Z0)........000006329F001002
Device Specific.(Z1)........C4IPNAR1
Device Specific.(Z2)........0068
Device Specific.(Z3)........14271
Device Specific.(Z4)........
Device Specific.(Z5)........22
Device Specific.(Z6)........N46243
Hardware Location
Code......U5887.001.G17X00G-P1-D6
If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model”
fields match the one listed in section 1.1 AND the "ROS Level and
ID...." field of that data is below “4E415231", this microcode applies.
Note: Drive microcode level in “ROS Level and ID …” field is displayed in
Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character
converts to a 2-digit hex number. For example in VPD displayed above, 4E
Hex= ASCII character "N"; 41 Hex= ASCII character "A"; 52 Hex=ASCII character
"R"; 31 Hex=ASCII character "1", microcode
level is "NAR1".
Also note that the microcode level "NAR1" is displayed in “Z1”
field.
===============================================================
2.3 Transferring
and Unpacking the Microcode Update Package
a) Make a directory on AIX
system to receive the AIX format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
You'll see the filename is C10K1800-4K.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x C10K1800-4K.bin
./C10K1800-4K.bin
[Don't overlook the periods (.) in above command.]
The
directory C10K1800-4K with microcode files
listed in section 1.1 will be added to /tmp/fwupdate.
d-Enter
the following command to copy the microcode files to " /etc/microcode
" directory :
cp /tmp/fwupdate/C10K1800-4K/HUC* /etc/microcode
Note: The
instructions that follow are specific AIX commands. AIX commands are CASE
(lower and upper) SENSITIVE,
and must be entered exactly as shown, including
filenames.
a)
Make a directory on an AIX system to receive the RPM format file.
Enter: mkdir
/tmp/microcode
b)
Transfer the RPM format file to the /tmp/microcode
directory.
You'll see the filename is C10K1800-4K-NAR1-AIX.rpm
c)
Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos --force C10K1800-4K-NAR1-AIX.rpm
The
file size and checksum will be verified.
The
microcode files will be added to /etc/microcode/
Copy
microcode updates from the CD-ROM to standard locations on your local disk:
1.
RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as
this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files
in case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks;
however, as a precaution, ensure that a backup operation has been performed on
the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently? YES
Is system reboot needed to activate the
microcode: Yes if stand alone diagnostics CD is used, NO if concurrent
diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone
diagnostics is used(using Diagnostics CD);
Approximately 5 minutes/drive if concurrent diagnostics is used.
2.4.1 Concurrent Download
1.
Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE***
The microcode installation occurs while the attached drives are
available for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to continue.
/etc/microcode
optical media (ISO
9660 file system format)
cd0
- Use /etc/microcode
if microcode files were added to /etc/microcode directory
- Use “optical media” if code are in CD/DVD
NOTE: A prompt will ask you to insert the
microcode diskette in diskette drive(if Diskette is
selected above). Insert the diskette and press ENTER
7- Display shows a list of microcodes available for the selected drive, highlight
option "M HUC...", the latest
microcode for the drive and press ENTER. A message may warn you that current
level of microcode is not available on the media, press ENTER to continue.
8. You will receive a msg. "Current
Microcode is...." and "Download has completed successfully"
(this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.2 Standalone (Service Mode) Download
This procedure is
used for all drives including rootvg or paging space
drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is
recommended to use the same level
of Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
Microcode level to download
-----------------------------[ latest]
Download latest level even if
-----------------------------[ yes]
current is missing
NOTE: A prompt will ask you to insert the
microcode diskette into the floppy drive. Insert the diskette which
accompanies these instructions. If this level is already installed in the drive
you've selected a message will let you know. A message also may come up to let
you know that the Diskette(or Disk) does not have the
previous level microcode file. This is true and is not required to complete the
download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.
======================================================
Microcode can be
updated using the iprconfig
utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to update
microcode is
selected, all available microcode levels are
presented to choose to download.
1. If using SLES 9
base, install the package by typing:
rpm -ivh --ignoreos C10K1800-4K-NAR1-LINUX.rpm
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select
Download microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in Progress” with
elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the
"Firmware Version" field
--------------------------------------------------------------------------
Microcode can be
updated using the iprconfig
utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to
update microcode is
selected, all available microcode levels are
presented to choose to download.
1. tar -C-xzvf C10K1800-4K-NAR1-LINUX.tgz
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select
Download microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in Progress” with elapsed
time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk to
query by typing a 1 next to it and pressing "Enter"
4. Look at the "Firmware Version" field