*IBM pSeries Servers* *Microcode Update for SAV-XP 10K.5 73/146/300/600/900 GB* *SAS Hard Disk Drive* *Microcode Level B55E* DATE: February 17, 2014 *Table of Contents* 1. General Information <#_Toc311027593> 1.1 Disk Drives Affected <#_Toc311027594> 1.2 Microcode Change History <#_Toc311027595> 2. AIX and VIOS (PowerVM Virtual I/O Server) <#_Toc311027596> Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code <#_Toc311027597> 2.1 Installation Time <#_Toc311027598> 2.2 Determine Drive Model, FRU&PN and Current Microcode Level <#_Toc311027599> 2.3.1 Internet AIX self extracting file (.bin) <#_Toc311027600> 2.3.2 Internet RPM package <#_Toc311027601> 2.3.3 CD-ROM <#_Toc311027602> 2.4 Microcode Download Procedure <#_Toc311027603> 3. Linux Operating System <#_Toc311027604> 3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL 4) <#_Toc311027605> 3.2 RHEL 3 <#_Toc311027606> 3.3 SLES 8 SP4 <#_Toc311027607> 7. Document Change History <#_Toc311027608> *===============================================================* 1. General Information The Microcode files provided in this package are for SAS disk drives used in IBM *Blades and ITE systems with *AIX or Linux operating systems 1.1 Disk Drives Affected Below is the list of microcode files in this package: NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction * * Size Disk Drive Model FRU# P/N (VPD) Microcode Filename Checksum 36GB ST936705SS 26K5778 26K5266 ST93670.434D5053.42353545 20772 73GB ST973405SS 26K5779 26K5267 ST97340.434D5053.42353545 146GB ST9146805SS 42D0422 42C0251 ST91468.434D5053.42353545 300GB ST9300605SS 42D0628 42D0631 ST93006.434D5053.42353545 42D0638 42D0641 600GB ST9600205SS 49Y2023 49Y2026 ST96002.434D5053.42353545 900GB ST9900805SS 00J0017 81Y3804 ST99008.434D5053.42353545 81Y9651 81Y3805 1.2 Microcode Change History Release date Code level Change Description February 2014 B55E Added SMART trip based on a scrub event-other fixes and enhancements November 2012 B55D Reliability enhancement- enabled ?Forced periodic load/unload? of head stack. October 2012 B55C Fixes and enhancements June 2012 B559 Added new Assembly PN Fixed dithering stall issue : Dithering operation is stalled for up to 10 minutes when drive is idle (no commands from the host are received). November 2011 B556 Fixes and Enhancements Sept , 2011 B554 Initial Release =============================================================== 2. AIX and VIOS (PowerVM Virtual I/O Server) Note: For VIOS systems, microcode of shared physical I/O resources can only be updated from VIOS partition. To update disk drive microcode, from VIOS partition, enter the following command: oem_setup_env Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code 2.1 Installation Time /Approximately 20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX concurrent diagnostics./ 2.2 Determine Drive Model, FRU&PN and Current Microcode Level To see the drive type and current microcode level, Execute the following command: lscfg -vl hdisk* |pg ; For drives NOT configured for RAID lscfg ?vl pdisk* |pg ; For drives configured for RAID DEVICE LOCATION DESCRIPTION hdisk1 U78A5.001.BARON40-P1-T5-L60000-L0 SAS Disk Drive (146800 MB) Manufacturer.......................IBM-ESXS Machine Type and Model......ST9600205SS FRU Number....................... 49Y2023 ROS Level and ID................*42353545* Serial Number......................3WN05CCH EC Level..............................N24774 Part Number......................... 49Y2026 Device Specific.(Z0)........000005329F011002 Device Specific.(Z1)........0412*B55E* Device Specific.(Z2)........1000 Device Specific.(Z3)........10019 Device Specific.(Z4)........0001 Device Specific.(Z5)........22 Device Specific.(Z6)........N24774 Hardware Location Code......U78A5.001.WIH847A-P2-D1 If the data returned in the ?Part Number?, ?FRU Number?, and ?Machine Type and Model? fields match the one listed in section 1.1 AND the "ROS Level and ID...." field of that data is below "42353544", this microcode applies. If this level is already installed then the "ROS Level and ID...." shows: "42353544" *Note*: Drive microcode level in ?ROS Level and ID ?? field is displayed in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character converts to a 2-digit hex number. For example in VPD displayed above, 42 Hex= ASCII character "*B*"; 35 Hex= ASCII character "*5*"; 35 Hex=ASCII character "*5*"; 45 Hex=ASCII character "*E*", microcode level is "*B55E*". Also note that the microcode level "* B55E*" is displayed in ?Z1? field. =============================================================== *2.3 Transferring and Unpacking the Microcode Update Package*** 2.3.1 Internet AIX self extracting file (.bin) a) Make a directory on an AIX system to receive the AIX format file. Enter: mkdir /tmp/fwupdate b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ..."). You'll see the filename is *SAV-XP10K5.bin* c) Unpack the file by executing the instructions below. Enter the commands: cd /tmp/fwupdate chmod +x SAV-XP10K5.bin ./SAV-XP10K5.bin [Don't overlook the periods (.) in the above command.] The directory SAV-XP10K5 with microcode files listed in section 1.1 will be added to /tmp/fwupdate. d-Enter the following command to copy the microcode files to " /etc/microcode " directory : cp /tmp/fwupdate/ SAV-XP10K5/ST9* /etc/microcode e- If transferring files to a different system using floppy diskettes, use the following procedure to copy files to diskette Note: Don't overlook the complete path of microcode files, AIX Diag microcode download _will__ not work if files are not copied with complete path onto the diskette_. Enter the following command to copy microcode file(s) onto a floppy diskette ls /etc/microcode/ microcodefilename | backup -ivf /dev/rfd0 where microcodefilename is microcode file that is needed, for example: ls /etc/microcode/ ST96002.434D5053.42353545| backup -ivf /dev/rfd0 2.3.2 Internet RPM package *Note:* The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE, and */must/* be entered exactly as shown, including filenames. a) Make a directory on an AIX system to receive the RPM format file. Enter: mkdir /tmp/microcode b) Transfer the RPM format file to the /tmp/microcode directory. You'll see the filename is *SAV-XP10K5?B55E-AIX.rpm* c) Unpack the file by executing the instructions below: Enter the commands: *rpm -ihv --ignoreos --force **SAV-XP10K5?B55E-AIX.rpm *;(please note, there are two dashes) The file size and checksum will be verified. The microcode files will be added to /etc/microcode/ 2.3.3 CD-ROM Copy microcode updates from the CD-ROM to standard locations on your local disk: 1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM" 2. Microcode files will be copied to /usr/lib/microcode *Notes:* - "/etc/microcode" is a symbolic link to "/usr/lib/microcode". - If permission does not allow the copy to the above stated directory or file then the user will be prompted for a new location. *========================================================* 2.4 Microcode Download Procedure /Warning:/ Do not power off the system or the drive during microcode download as this may permanently damage the disk drive *NOTE:* Please save current and older versions of the microcode update files in case you need to restore your system. /Caution:/ The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation. /Can microcode be installed Concurrently?/ YES /Is// system reboot needed to activate the microcode: /Yes if stand alone diagnostics CD is used, NO if concurrent diagnostics is used. /Installation Time: /Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if concurrent diagnostics is used. *2.4.1. Concurrent Download* 1. Type diag at the prompt. 2. Select the "Task Selection" from diagnostics menu. 3. Select "Microcode Download" from "Task Selection" menu. 4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then press "F7" to commit.. 5- A small screen displays the message " *** NOTICE*** The microcode installation occurs while the attached drives are available for use..... " Press enter to continue 6. Select the source for microcode, use arrow key to go up/down, Enter to continue. /etc/microcode diskette - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk - Use diskette if using diskette as the source for download NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above). Insert the diskette and press ENTER 7- Display shows a list of microcodes available for the selected drive, highlight option "M ST9xx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue. 8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully" (this may take a few minutes) 9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode. 10. Exit diagnostic(and reboot if needed). *2.4.2 Standalone (Service Mode) Download* This procedure is used for all drives including rootvg or paging space drives 1. Properly shutdown the system. 2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is recommended to use the same level of Diagnostic CD as the AIX ). 3. Select the "Task Selection" from diagnostics menu. 4. Select "Microcode Download" from "Task Selection" menu. 5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER. 6. Press "F7" to commit. (The current microcode level of the resource you selected earlier will be displayed at the top of the screen) 7. Make the following selections on the next screen: Select Input Device --------------------------------------- [ diskette] Microcode level to download -----------------------------[ latest] Download latest level even if -----------------------------[ yes] current is missing NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive. Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download. PRESS "F7" to commit 8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully" (this may take a few minutes) 9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode. 10. Exit diagnostic and reboot system in normal mode. * * *======================================================* 3. Linux Operating System 3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL 4) Microcode can be updated using the iprconfig utility. The iprconfig utility allows for multiple levels of adapter and device microcode to exist on the system at the same time. After the device to update microcode is selected, all available microcode levels are presented to choose to download. 1. a) If using SLES 9 base, install the package by typing: rpm -ivh --ignoreos *SAV-XP10K5?B55E-AIX.rpm* b) If using SLES 9 SP1 or better or RHEL 4 or better, install the package by typing: rpm -ivh *SAV-XP10K5?B55E-LINUX.rpm* 2. Update the microcode by typing: iprconfig Press Enter. 3. Select Download microcode and press Enter. 4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected. 5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter. 6. Press Enter _again_ to confirm the download (display shows ?Microcode Download in Progress? with elapsed time) 7. If multiple devices were selected, repeat from Step 5 for the next device. To check the microcode level: 1. Start iprconfig utility, 2. Select "Display hardware status" option. 3. Select disk to query by typing a 1 next to it and pressing "Enter" 4. Look at the "Firmware Version" field -------------------------------------------------------------------------- 3.2 RHEL 3*:* Microcode can be updated using the iprupdate utility. If iprupdate finds newer microcode on the system it will be downloaded to the disk. 1. Install the package by typing: rpm -ivh --ignoreos *SAV-XP10K5?B55E-AIX.rpm* Press Enter. 2. Update the microcode by typing: iprupdate Press Enter. To check the microcode level: 1. Start iprconfig utility, 2. Select "Display disk hardware status" option. 3. Find the disk you wish to query and note its serial number. 4. Type "d" to get to the "Display disk unit details" screen. 5. Select disk to query by typing a 5 next to it and pressing "Enter" 6. Look at the "Firmware Version" field ------------------------------------------------------------------------- 3.3 SLES 8 SP4 Microcode can be updated using the sisupdate utility. If sisupdate finds newer microcode on the system it will be downloaded to the disk. 1. Install the package by typing: rpm -ivh --ignoreos *SAV-XP10K5?B55E-AIX.rpm* Press Enter. 2. Update the microcode by typing: sisupdate Press Enter. To check the microcode level: 1. Start sisconfig utility, 2. Select "Display disk hardware status" option. 3. Find the disk you wish to query and note its serial number. 4. Type "d" to get to the "Display disk unit details" screen. 5. Select disk to query by typing a 5 next to it and pressing "Enter" 6. Look at the "Firmware Version" field 7. Document Change History