IBM
pSeries Servers
Microcode Update for Alegro
AL12SE
73/146/300/600GB
SAS Hard Disk Drive
Microcode Level 610E
DATE: January 15, 2014
Revised March 22, 2016
Table of Contents
2. AIX and VIOS (PowerVM Virtual I/O Server)
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL
4)
===============================================================
The Microcode files provided in this package are for SAS disk drives
used in IBM Power systems with
AIX or Linux operating systems
Below
is the list of microcode files in this package:
NOTE: To insure the integrity of microcode files, please
make sure the checksum value is correct after extraction
Model |
Size |
PN |
FRU |
Microcode File |
Check sum |
MBF600RC |
600GB |
74Y7438 |
74Y4900 |
MBF2600.A1700D36.36313045 |
|
74Y7442 |
74Y4901 |
||||
74Y7648 |
74Y4936 |
||||
74Y9213 |
74Y9214 |
||||
MBF300RC |
300GB |
74Y7437 |
44V6833 |
MBF2300.A1700D36.36313045 |
|
300GB |
74Y7441 |
46K4812 |
|||
MBF2147RC |
146GB |
74Y9209 |
42R8392 |
MBF2147.A1700D36.36313045 |
|
MBF2073RC |
73GB |
74Y9208 |
42R8392 |
MBF2073.A1700D36.36313045 |
Release date |
Code level |
Change Description |
January 2014 |
610E |
-Fixed 04/44A3 (Buffer CRC) error on write commands |
May 2012 |
610D |
- Improved firmware to retry as long as power supply after
EPOW. |
October 2011 |
610A |
Fixes
the Timeout problem that occurs under Multi-Initiator environment and
multiple I_T_Nexus connection when test Unit Ready
(NACA=1) commands are issued from different I_T_Nexus
simultaneously and ACA Condition is generated causing a Hard Command timeout. |
September 2011 |
6108 |
FW
fix to resolve Unrecovered read errors when IBM Power Systems drive FW is
loaded over new drives that has been previously formatted to support PI type
2. |
June 2011 |
6107 |
Initial Release |
===============================================================
Note:
For VIOS systems, microcode of shared physical I/O resources can only be
updated from VIOS partition.
To
update disk drive microcode, from VIOS partition, enter the following
command:
oem_setup_env
Approximately
20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX
concurrent diagnostics.
2.2 Determine Drive Model, FRU&PN and Current
Microcode Level
To see the drive type and current microcode level, Execute the following
command:
lscfg -vl hdisk* |pg ; For
drives NOT configured for RAID
lscfg –vl pdisk*
|pg ; For drives configured for RAID
DEVICE LOCATION DESCRIPTION
Vital
Product Data (VPD)
hdisk16 U5886.001.P75P004-P1-D1 SAS Disk Drive (146800 MB)
Manufacturer................IBM
Machine Type and Model...... MBF600RC
FRU Number.................. 74Y4900
ROS Level and ID............ 36313045
Serial Number...............3SD01J3J
EC Level....................L36403
Part Number................. 74Y7438
Device Specific.(Z0)........000005329F003002
Device Specific.(Z1)........0918610E
Device Specific.(Z2)........0021
Device Specific.(Z3)........08315
Device Specific.(Z4)........
Device Specific.(Z5)........22
Device Specific.(Z6)........L36403
Hardware Location
Code......U5886.001.P75P004-P1-D1
If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model” fields
match the one listed in section 1.1 AND the "ROS Level and ID...."
field of that data is below "36313045",
this microcode applies. If this level is already installed then the "ROS
Level and ID...." shows: "36313045"
Note: Drive microcode level in “ROS Level and ID …” field is displayed
in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII
character converts to a 2-digit hex number. For example in VPD displayed above,
36 Hex= ASCII character "6"; 31 Hex= ASCII character "1"; 30 Hex=ASCII character "0"; 45 Hex=ASCII character "E", microcode level is "610E". Also note that the microcode level " 610E" is displayed in “Z1”
field.
===============================================================
2.3 Transferring and
Unpacking the Microcode Update Package
a) Make a directory on an AIX
system to receive the AIX format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
You'll see the filename is AL12SE.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x AL12SE.bin
./ AL12SE.bin
[Don't overlook the periods (.) in the above command.]
The directory AL12SE with microcode files
listed in section 1.1 will be added to /tmp/fwupdate.
d-Enter the following command to copy the
microcode files to " /etc/microcode "
directory :
cp /tmp/fwupdate/AL12SE /MB* /etc/microcode
e-
If transferring files to a different system using floppy diskettes, use the
following procedure to copy files to diskette
Note: Don't overlook the complete path of microcode files, AIX Diag microcode download
will not
work if files are not copied with complete path onto the diskette.
Enter
the following command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename | backup -ivf /dev/rfd0
where microcodefilename is microcode file that
is needed, for example:
ls /etc/microcode/ MB* | backup -ivf /dev/rfd0
Note: The
instructions that follow are specific AIX commands. AIX commands are CASE
(lower and upper) SENSITIVE,
and must be entered exactly as shown, including
filenames.
a) Make
a directory on an AIX system to receive the RPM format file.
Enter: mkdir
/tmp/microcode
b)
Transfer the RPM format file to the /tmp/microcode
directory.
You'll see the filename is AL12SE–610E-AIX.rpm
c) Unpack
the file by executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos
--force AL12SE–610E-AIX.rpm ;(please note, there are two dashes)
The
file size and checksum will be verified.
The
microcode files will be added to /etc/microcode/
Copy
microcode updates from the CD-ROM to standard locations on your local disk:
1.
RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as
this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files
in case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks;
however, as a precaution, ensure that a backup operation has been performed on
the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently? YES
Is system reboot needed to activate the
microcode: Yes if stand alone diagnostics CD is used, NO if concurrent
diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone
diagnostics is used(using Diagnostics CD);
Approximately 5 minutes/drive if concurrent diagnostics is used.
2.4.1. Concurrent Download
1.
Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE***
The microcode installation occurs while the attached drives are
available for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to continue.
/etc/microcode
diskette
- Use /etc/microcode
if "restore" command is used to copy files from diskette onto the
disk
- Use diskette if using diskette as the source for download
NOTE: A prompt will ask you to insert the
microcode diskette in diskette drive(if Diskette is
selected above). Insert the diskette and press ENTER
7- Display shows a list of microcodes
available for the selected drive, highlight option "M
MBFxx...", the latest microcode for the
drive and press ENTER. A message may warn you that current level of microcode
is not available on the media, press ENTER to continue.
8. You will receive a msg. "Current
Microcode is...." and "Download has completed successfully"
(this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.2 Standalone (Service Mode) Download
This procedure is
used for all drives including rootvg or paging space
drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is
recommended to use the same level
of Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
Microcode level to download
-----------------------------[ latest]
Download latest level even if
-----------------------------[ yes]
current is missing
NOTE: A prompt will ask you to insert the
microcode diskette into the floppy drive. Insert the diskette which
accompanies these instructions. If this level is already installed in the drive
you've selected a message will let you know. A message also may come up to let
you know that the Diskette(or Disk) does not have the
previous level microcode file. This is true and is not required to complete the
download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.
======================================================
Microcode can be
updated using the iprconfig utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to
update microcode is
selected, all available microcode levels are
presented to choose to download.
1.
a) If using SLES 9 base, install the package by
typing:
rpm -ivh --ignoreos AL12SE–610E-AIX.rpm
b) If using SLES 9 SP1 or better or RHEL 4 or better, install the
package by typing:
rpm -ivh AL12SE–610E-LINUX.rpm
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select
Download microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in Progress” with
elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the
"Firmware Version" field
--------------------------------------------------------------------------
Microcode can be
updated using the iprupdate utility. If iprupdate finds newer
microcode on the system it will be downloaded to the
disk.
1. Install the
package by typing:
rpm -ivh --ignoreos AL12SE–610E-AIX.rpm
Press Enter.
2. Update the microcode
by typing:
iprupdate
Press Enter.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the disk
you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the
"Firmware Version" field
-------------------------------------------------------------------------
Microcode can be
updated using the sisupdate utility. If sisupdate finds newer
microcode on the system it will be downloaded to the
disk.
1. Install the
package by typing:
rpm -ivh --ignoreos AL12SE–610E-AIX.rpm
Press Enter.
2. Update the
microcode by typing:
sisupdate
Press
Enter.
To check the
microcode level:
1. Start sisconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the disk
you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the "Firmware
Version" field
March 22, 2016:
Corrected rpm command in section 2.3.2