IBM eServer
PCI-X DDR Ultra320 SCSI Adapter (CCIN: 571A, HV 1912)
PCI-X DDR Ultra320 SCSI RAID Adapter (CCIN: 571B, HV 1913)
PCI-X
SCSI AUX Cache Card (CCIN: 574F)
DATE: Dec 03, 2012
Table of Contents
2.0 General Information
2.1 Installation Time
2.2 Machine's Affected
2.3 AIX Requirements
2.4 Linux Requirements
3.0 Determine the Current Microcode Level for AIX
3.1 Determine the Current Microcode Level for
Linux
4.0 Downloading
and Unpacking the Firmware Update
Package from CORE
4.1 Downloading the RPM Format File to the Target
Server
4.2 Discovery Tool Microcode CD-ROM creation and download
instructions
5.0 Verifying microcode before download and notes
5.1 Microcode Download Procedure-PCI-X DDR Ultra320 SCSI/SCSI
RAID Adapter for AIX
5.2 Microcode Download Procedure-PCI-X DDR Ultra320
SCSI/SCSI RAID Adapter for Linux (SLES 9 SP1, RHEL4 and
above)
=====================================================================================
07130029 | -Contains fixes for all known issues |
07130025 | -Enhancements to improve reliability when attached to 7031-D24. |
07130015 |
-Change in drive strength settings to workaround CRC issues found in
certain 7311-D20 internal DASD backplane configuration. This CRC
issue is likely when ST3xxxx55LC DASD is installed in slot 1 of the
7311-D20 internal DASD backplane. A similar DASD microcode change will be released, in level C808, for ST3xxxx55LC. Installing either of these microcode levels will address the situation. |
0713000c |
-iSeries enhancement for all U320 SCSI Controllers. Enhancement to
recognize Hot Spare (RAID 0) DASD. -GA microcode level necessary for SCSI RAID AUX Cache Card Support. |
05130080 |
-Resolves SCSI errors/compatibility with the HHLTO2 tape drive -Resolves specific LUN mode negotiation problems |
05130077 |
-Fix for a system hang at 0255/0266 after a SCSI Cable Pull test. -Improve error logging for 9010 errors by including the Bats status area. -Change handling of the Handle Query Resource State Command with the sync override bit set. |
0513006f |
CCIN 2780: Cache Battery Pack Warning might be incorrectly reset and
battery power-on times reinitialized. This PTF will prevent the problem
from occurring in the future. If the problem has already occurred, the
battery packs must be replaced via normal service procedures. CCIN 5702/1974, 5703/1975, 5709/1976, 570A/570B, 573D/1908/1907, 2780, 571A/1912, 571B/1913: -I/O Adapter code to support the Prepare for Shutdown command. -I/O Adapter recovery was enhanced to prevent system performance degradation due to excessive SCSI disk drive recovery. |
05130065 |
GA Level for CCIN 571B/1913 -Dual-Initiator (HA) mode fixes: |
0513005d | GA Level for CCIN 571A/1912 |
Drive Type |
Microcode Level (Hex) |
Microcode level (ASCII as
appears in VPD) |
Cheetah73LP (9GB) |
C54E | 43353445 |
Cheetah73LP (18GB+) |
C50E | 43353045 |
Cheetah146LP | C50F | 43353046 |
Cheetah73LP-X15 | C51A | 43353141 |
Ultrastar73 | S5DE | 53354445 |
US146Z10 | S28C | 53323843 |
SUBJECT: PCI-X DDR Ultra320 SCSI/SCSI RAID Adapter
******* PLEASE READ THIS ENTIRE NOTICE *********
2.1
Installation Time:
Approximately 30 minutes
2.2
Machine's Affected:
7311-D20
9110-510
9111-285/520
9112-265
9113-550
9114-275
9115-505
9117-570
9117-MMA
9118-575
9119-590/595
9123-710
9124-720
9131-52A
9133-55A
9406-520/550/750
PCI-X DDR Ultra320 SCSI Adapter (CCIN: 571A, HV 1912)
PCI-X DDR Ultra320 SCSI RAID Adapter (CCIN: 571B, HV 1913)
For support: AIX 5.2 ML_07, AIX 5.3 ML_03 or above along w/ the aforementioned minimum DASD microcode requirements.
PCI-X SCSI AUX Cache Card (CCIN: 574F)
For support: AIX
5.2 TL_10 or AIX 5.3 TL_06 along w/ the aforementioned minimum
DASD
microcode requirements.
PCI-X DDR Ultra320 SCSI Adapter (CCIN: 571A, HV 1912)
PCI-X DDR Ultra320 SCSI RAID Adapter (CCIN: 571B, HV 1913)
For support:
SUSE Linux Enterprise Server 9
Service Pack 2 for POWER or later
Red Hat Enterprise Linux AS for POWER Version 4 Update 2 or later
PCI-X SCSI AUX Cache Card (CCIN: 574F)
No Linux support
3.0 Determine the Current Microcode Level for AIX:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SCSI RAID Adapters installed in the system by typing:
"lsdev -C | grep sisscsia" or "lsdev -C | grep sisioa"
Note: All of the SCSI RAID initiators addresses that are installed will be displayed. The names will be sisioaX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
"lscfg -vl sisscsiaX" or "lscfg -vl sisioaX"
Where X is the number/s of the previous command. The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
sisscsia0
U787B.001.DNW3475-P1-C5 PCI-XDDR Dual Channel U320 SCSI
Adapter
PCI-XDDR Dual Channel Ultra320 SCSI Adapter:
Part Number.................39J1643
FRU Number..................39J1643
Serial Number...............YL1095101003
Manufacture ID..............0009
EC Level....................0
ROM Level (alterable).......0513003f
Product Specific.(Z0).......571A
Product Specific.(Z1).......1
Device Specific.(YL)........U787B.001.DNW3475-P1-C5
DEVICE LOCATION DESCRIPTION
sisioa3 U0.2-P1-I3
PCI-XDDR Dual Channel U320 SCSI RAID Adapter
PCI-XDDR Dual Channel Ultra320 SCSI RAID Adapter:
Part Number.................97P4152
FRU Number..................97P4152
Serial Number...............YL3495066041
Manufacture ID..............0049
EC Level....................4
ROM Level.(alterable).......0513003f
Product Specific.(Z0).......571B
Product Specific.(Z1).......1
Device Specific.(YL)........U0.2-P1-I3
DEVICE LOCATION DESCRIPTION
sisioa1 U5294.001.10397A2-CB1-C02
PCI-XDDR Auxiliary Cache Adapter
PCI-XDDR Auxiliary Cache Adapter:
Part Number.................42R5133
FRU Number..................42R5133
Serial Number...............YL10C7030007
Manufacture ID..............000C
EC Level....................0
ROM Level.(alterable).......07130029
Product Specific.(Z0).......574F
Product Specific.(Z1).......1
Device Specific.(YL)........U5294.001.10397A2-CB1-C02
If the ROM Level is less
than 07130029 then you should update the microcode.
3.1
Determine the Current Microcode Level for Linux:
1) Type "iprconfig"
2) Select "Display hardware status"
3) Select SCSI adapter by typing a "1" in front of it (571A, 571B, 1912 or
1913) and pressing
Enter.
4) The Command will
produce output similar to
"Firmware Version . . . . .
. . . . . . . : 07130029"
If the Firmware Version is less
than 07130029 then you should update the microcode.
4.0 Downloading and Unpacking the Firmware Update Package from CORE
NOTE: The CORE image will now be the RPM Format File.4.1 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX or Linux system:
Note: The instructions that follow are specific AIX/Linux commands. AIX/Linux commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1) Make a
directory on an AIX/Linux system to receive the RPM format file.
Enter: "mkdir /tmp/microcode"
Enter:
"mkdir /tmp/microcode/RPM"
2) Transfer the
RPM format file to the /tmp/microcode/RPM directory (using "Save as ...").
Change to that directory, "cd /tmp/microcode/RPM".
You'll see the
filenames for the RPM files.
A) For AIX,
the filename is pci.1014028C.13-07130029-1.aix5.1.noarch.rpm
B) For SLES9 SP1,
RHEL4 & above,
the filename is pci.1014028C.13-07130029-1.Linux.noarch.rpm
3) Unpack the file by executing the instructions
below:
A) For AIX,
type "rpm -ihv --ignoreos --force pci.1014028C.13-07130029-1.aix5.1.noarch.rpm"
B) For SLES9
SP1, RHEL4 & above,
type "rpm -ihv --ignoreos --force pci.1014028C.13-07130029-1.Linux.noarch.rpm"
4a) For AIX:
The microcode files will be added to /usr/lib/microcode/.
4b) For SLES9 SP1, RHEL4
& above:
The microcode files will be added to /lib/firmware/.
4.2 Discovery Tool Microcode CD-ROM creation and download instructions
To obtain information how to burn a
CD-ROM and run the Discovery Tool for an AIX System please go to: http://techsupport.services.ibm.com/server/mdownload/CDROMhelp.html
1) After running the Discovery Tool successfully the "/tmp/microcode/RPM"
directory was created and your rpm files are copied from the CD-ROM.
2) Change to that directory, "cd /tmp/microcode/RPM".
3) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos --force
pci.1014028C.13-07130029-1.aix5.1.noarch.rpm
4) Microcode files will be copied to "/etc/microcode". The file
size and checksum of the microcode image will be verified in Section
5.0
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Verifying microcode before download and notes
NOTE: Microcode download must be performed
separately for each Adapter bus under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
NOTE: Microcode Download CAN be performed concurrently.
Installation Time: Approximately 30 min System Time.
Please verify the file size and checksum of the raw microcode files
matches the below.
Filesize: 1316684
Checksum: 59235
For AIX: "ls -l /usr/lib/microcode/53495313.07130029" to
verify Filesize.
"sum /usr/lib/microcode/53495313.07130029"
to verify Checksum.
For SLES9 SP1, RHEL4 &
above: "ls
-l /lib/firmware/pci.1014028C.13.07130029"
to
verify Filesize.
"sum /lib/firmware/53495313.07130029" to
verify Checksum.
For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SCSI device in order to update the code. Follow this procedure for each partition:
For AIX:
A) Log into the
target partition.
B) Type: "cd /usr/lib/microcode"
C) FTP (for AIX)
or SFTP (for Linux) to the partition
that has the media bay assigned. (ie. ftp/sftp partition1.ibm.com)
D) Type: "cd /usr/lib/microcode"
E) If using FTP
then Type: "bin"
F) Type: "get 53495313.07130029"
G) Type: "quit"
For SLES9
SP1, RHEL4 & above:
A) Log into the
target partition.
B) Type: "cd
/lib/firmware"
C) SFTP to the
partition
that has the media bay assigned. (ie. "sftp partition1.ibm.com")
D) Type: "cd /lib/firmware"
E) Type: "get pci.1014028C.13.07130029"
F) Type: "quit"
5.1 Microcode Download Procedure-PCI-X DDR Ultra320 SCSI/SCSI RAID Adapter for AIX
Procedure: