Microcode Update for ZeusIOPS
73GB
SAS Solid State Drive
Microcode Level G00R
DATE: April 9, 2012
Table of Contents
2. AIX and VIOS (PowerVM Virtual I/O Server) Operating System
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.2.2 SCSI Drives attached to PCI SCSI RAID
Controllers
2.3 Transferring and Unpacking
the Microcode Update Package
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
2.4.1 Concurrent Download
2.4.2 Stand Alone (Service Mode) Download
3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL
4)
===============================================================
The Microcode files provided in this package are for
with AIX or Linux operating systems
Below
is the list of microcode files in this package:
NOTE: To insure the integrity of microcode files,
please make sure the checksum value is correct after extraction
Size
Disk Drive Model
FRU# P/N (VPD) Microcode File Name Checksum
-------- --------------------- ----------- ------------- ---------------------------------- ----------
73GB Z16IZD2B-73 44V6821 44V8674 Z16IZD2.A1700D29.47303052 16260
73GB Z16IZD2B-73 44V6819 44V8673 Z16IZD2.A1700D29.47303052 16260
73GB Z16IZD2B-73 44V6825 44V8675 Z16IZD2.A1700D29.47303052 16260
Release date |
Code level |
Change Description |
April 2012 |
G00R |
The firmware
has been changed to prevent the false detection of power back-up failures |
October 2011 |
G00Q |
-The firmware has been changed to continue a Format Unit
operation across a Task Management Abort Task Set function |
January 2011 |
G00P |
This code fixes
LUN reset to clear a “Reserve” condition, also it contains other
fixes and enhancements |
Oct 2009 |
G00M |
Performance Improvement by
implementing Skip function |
August 2009 |
G00L |
1- Fixed an unexpected
SMART trip. A code bug causes drive to report PFA (01/5D/00/33) incorrectly indicating
excessive recoverable read error. 2- Implemented a fix for a
Data miscompare error reported under a unique test
condition |
May 2009 |
G00B |
Initial Release |
===============================================================
Note:
For VIOS systems, microcode of shared physical I/O resources can only be
updated from VIOS partition.
To update
disk drive microcode, from VIOS partition, enter the following command:
oem_setup_env
Then
follow the instruction in section 2.3 to transfer/extract the microcode file,
and section 2.4.1 to update the disk drive code.
Approximately
20 minutes if using Diagnostics CD; Approximately 5
minutes/drive using AIX concurrent diagnostics.
2.2 Determine Drive
Model, FRU&PN and Current Microcode Level
To see the drive type and current microcode level, Execute the following command:
lscfg -vl hdisk* |pg ; For
drives NOT configured for RAID
lscfg –vl pdisk* |pg ; For
drives configured for RAID
DEVICE LOCATION DESCRIPTION
pdisk0
Manufacturer................
Machine Type and
Model......Z16IZD2B-73
FRU
Number.....................44V6821
Serial
Number...................S08CR00Q
EC
Level...........................L36401
Part
Number......................44V6817
Device Specific.(Z0).........000005329F001002
Device Specific.(Z1).........0106F5G00R <----------- F5 is FPGA (HW) code
<-------- G00R is interface code
Device Specific.(Z2).........00SA
Device Specific.(Z3).........08363
Device Specific.(Z4)........
Device Specific.(Z5).........22
Device Specific.(Z6)........L36401
Hardware Location
Code......U5886.001.P77G078-P1-D4
If the data returned in the “Part Number”, “FRU Number”, and
“Machine Type and Model” fields
match the one listed in section 1.1
Note: Drive microcode level in “
===============================================================
2.3 Transferring and Unpacking the
Microcode Update Package
a) Make a directory on an AIX
system to receive the AIX format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate
directory (using "Save as ...").
You'll see the filename is ZeusIOPS.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x ZeusIOPS.bin
./ ZeusIOPS.bin
[Don't overlook the periods (.) in the above command.]
The directory ZeusIOPS
with microcode files listed in section 1.1 will be added to /tmp/fwupdate.
d-Enter the following command to copy the
microcode files to " /etc/microcode "
directory :
cp /tmp/fwupdate/
ZeusIOPS/Z*
/etc/microcode
Note: The
instructions that follow are specific AIX commands. AIX commands are CASE
(lower and upper) SENSITIVE,
and must be entered exactly as shown, including
filenames.
a)
Make a directory on an AIX system to receive the
Enter: mkdir
/tmp/microcode
b)
Transfer the
You'll see the filename is ZeusIOPS–G00R-AIX.rpm
c) Unpack
the file by executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos
--force ZeusIOPS–G00R-AIX.rpm ;(please note, there are two dashes)
The
file size and checksum will be verified.
The
microcode files will be added to /etc/microcode/
Copy
microcode updates from the CD-ROM to standard locations on your local disk:
1.
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as
this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files
in case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks;
however, as a precaution, ensure that a backup operation has been performed on
the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently? YES
Is system reboot needed to activate the
microcode: Yes if stand alone diagnostics CD is used, NO if concurrent
diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone
diagnostics is used(using Diagnostics CD);
Approximately 5 minutes/drive if concurrent diagnostics is used.
2.4.1 Concurrent Download
1.
Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE***
The microcode installation occurs while the attached drives are
available for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to continue.
/etc/microcode
diskette
- Use /etc/microcode
if "restore" command is used to copy files from diskette onto the
disk
- Use diskette if using diskette as the source for download
NOTE: A prompt will ask you to insert the
microcode diskette in diskette drive(if Diskette is
selected above). Insert the diskette and press ENTER
7- Display shows a list of microcodes available for the selected drive, highlight
option "M 47303052",
the latest microcode for the drive and press ENTER. A message may warn you that
current level of microcode is not available on the media, press ENTER to
continue.
8. You will receive a msg. "Current
Microcode is...." and "Download has completed successfully"
(this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.2 Standalone (Service Mode) Download
This procedure is
used for all drives including rootvg or paging space
drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is
recommended to use the same level
of Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
Microcode level to download
-----------------------------[ latest]
Download latest level even if
-----------------------------[ yes]
current is missing
NOTE: A prompt will ask you to insert the
microcode diskette into the floppy drive. Insert the diskette which
accompanies these instructions. If this level is already installed in the drive
you've selected a message will let you know. A message also may come up to let
you know that the Diskette(or Disk) does not have the
previous level microcode file. This is true and is not required to complete the
download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.
======================================================
Microcode can
be updated using the iprconfig utility. The iprconfig utility
allows
for multiple levels of adapter and device microcode to exist on the
system at
the same time. After the device to update microcode is
selected,
all available microcode levels are presented to choose to download.
1.
a) If using SLES 9 base, install the package by
typing:
rpm -ivh --ignoreos ZeusIOPS–G00R-AIX.rpm
b) If using SLES 9 SP1 or better or RHEL 4 or better, install the
package by typing:
rpm -ivh ZeusIOPS–G00R-LINUX.rpm
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select
Download microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in
Progress” with elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the
"Firmware Version" field
--------------------------------------------------------------------------
Microcode can
be updated using the iprupdate utility. If iprupdate finds newer
microcode
on the system it will be downloaded to the disk.
1. Install the
package by typing:
rpm -ivh --ignoreos ZeusIOPS–G00R-AIX.rpm
Press Enter.
2. Update the
microcode by typing:
iprupdate
Press Enter.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the
disk you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the
"Firmware Version" field
-------------------------------------------------------------------------
Microcode can
be updated using the sisupdate utility. If sisupdate finds newer
microcode
on the system it will be downloaded to the disk.
1. Install the
package by typing:
rpm -ivh --ignoreos ZeusIOPS–G00R-AIX.rpm
Press Enter.
2. Update the
microcode by typing:
sisupdate
Press Enter.
To check the
microcode level:
1. Start sisconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the
disk you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the "Firmware
Version" field