IBM
eServer
SAS Enclosure Services for FC 5886
01B5 Microcode Update
DATE: Oct 18, 2011
Table of Contents
2.0 General Information
2.1 Installation Time
2.2 Machine's Affected
2.3 AIX Requirements
2.4 Linux Requirements
3.0 Determine the Current Microcode Level for AIX
3.1 Determine the Current Microcode Level for
Linux
4.0 Downloading
and Unpacking the Firmware Update
Package from CORE
4.1 Downloading the RPM Format File to the Target
Server
4.2 Discovery Tool Microcode CD-ROM creation and download
instructions
5.0 Verifying microcode before download and notes
5.1 Microcode Download Procedure-SAS Enclosure Services for
FC 5886 for AIX
5.2 Microcode Download Procedure-SAS Enclosure Services
for FC 5886 for Linux
6.0 Microcode Readme Change History
=====================================================================================
01B5 |
5886 POWER CYCLE REQUIRED when updating 0197 -> 01Bx 1) Resolves issue with 497 day timer reset. Prior to this fix, ESM would reset during runtime when 497 day timer rolled over. This could cause SAS Fabric Errors. 2) Required for support with FC 5913 (CCIN 57B5). NOTE: It is best to apply this code level PRIOR to attaching to CCIN 57B5. (Apply this code using an older 3Gb SAS adapter, if possible.) If only CCIN 57B5 is available then attach only 1 adapter to the drawer for the purpose of microcode update. Once the microcode update is applied to both ESMs, power cycle the 5886 drawer Cable the 5886 drawer in a correct supported manner. |
0197 |
1) Extended SAS Expander communication timeout to 50 sec 2) Extended SSP timer to 42 sec In general, these changes are needed for systems where SSDs are used in the FC 5886 SAS Enclosure and the SAS adapter is in a slower MTM (7311-D20). |
0193 |
1) Improved pre-emphasis settings to optimally drive 15m cables. 0197
or above must be installed for all 15m cable setups. 2) Fixed EPOW handling to properly recover expander after NOTIFY/Expected Power Loss has been sent. 3) Improved diagnostic call out in Received Diagnostics page so more errors are bubbled up to summary bit status field. |
0184 | GA Level |
2.1
Installation Time:
Approximately 30 minutes
2.2
Machine's Affected:
FC 5886
2.3
AIX Requirements:
For support:
AIX 5.3 TL_06 w/ SP4 (Sevice Pack 4), AIX 5.3 TL_07, AIX 6.1 or above
For support:
SUSE Linux Enterprise Server 10-SP1
for POWER or above
Red Hat Enterprise Linux AS for POWER Version 4 Update 5, RHEL 5 or above
3.0 Determine the Current Microcode Level for AIX:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SES installed in the system by typing:
lsdev -C | grep ses
Note: All of the SAS RAID initiators addresses that are installed will be displayed. The names will be sesX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl sesX
Where X is the number/s of the previous command. The Command will produce output similar to
DEVICE LOCATION DESCRIPTION
ses10 U5886.001.0901113-C1 SAS
Enclosure Services Device
Manufacturer................IBM
Machine Type and Model......5886
ROM Level.(alterable).......0197
Serial Number...............00901113
FRU Number.................. 42R7599
Device Specific.(Z0)........0D00040227004002
Hardware Location Code......U5886.001.0901113-C1
ses11 U5886.001.0901113-C2 SAS Enclosure Services Device
Manufacturer................IBM
Machine Type and Model......5886
ROM Level.(alterable).......0197
Serial Number...............00901113
FRU Number.................. 42R7599
Device Specific.(Z0)........0D00040227004002
Hardware Location Code......U5886.001.0901113-C2
If the ROM Level and ID is
less than 01B5 then you should update the microcode.
3.1
Determine the Current Microcode Level for Linux:
1) Type "iprconfig"
2) Select "Display hardware status"
3) Select SES by typing a "1" in front of it and pressing
Enter.
4) The Command will
produce output similar to
"Firmware Version . . . . . . . .
. . . . : 0197"
If the Firmware Version is less than 01B5 then you should update the microcode.
4.0 Downloading and Unpacking the Firmware Update Package from CORE
NOTE: The CORE image will now be the RPM Format File.
1) After downloading the files from CORE on to your personal system
find the following files in the CORE destination directory (c:\ibmdocs\DISKIMG):
A) "ses.5886-01B5-1.aix6.1.noarch.rpm"
B) "ses.5886-01B5-1.Linux.noarch.rpm"
2) Log in to the Target Server
3) Create a directory, if not already existent (mkdir /tmp/microcode; mkdir /tmp/microcode/RPM)
4) Transfer the file to the Target Server "/tmp/microcode/RPM
directory" using ftp or another method. Change to that directory, "cd /tmp/microcode/RPM".
5a) For AIX:
Unpack the RPM file by using the following command: "rpm -ihv --ignoreos --force
ses.5886-01B5-1.aix6.1.noarch.rpm"
5b) For Linux:
Unpack the RPM file by using the following command: "rpm -ihv --ignoreos --force
ses.5886-01B5-1.Linux.noarch.rpm"
6a) For AIX:
The microcode files will be added to /usr/lib/microcode/.
6b) For Linux:
The microcode files will be added to /lib/firmware/.
4.1 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX or Linux system:
1) Make a directory on an AIX/Linux system to receive the RPM format file.
Enter: "mkdir /tmp/microcode"
Enter: "mkdir /tmp/microcode/RPM"
2) Transfer the RPM format file to the /tmp/microcode/RPM directory (using "Save as ..."). Change to that directory, "cd /tmp/microcode/RPM".
You'll see the
filenames for the RPM files.
A) For AIX:
The filename is ses.5886-01B5-1.aix6.1.noarch.rpm
B) For
Linux: The filename is
ses.5886-01B5-1.Linux.noarch.rpm
3) Unpack the file by executing the instructions
below:
A) For AIX:
Type "rpm -ihv --ignoreos --force ses.5886-01B5-1.aix6.1.noarch.rpm"
B) For Linux:
Type "rpm -ihv --ignoreos --force ses.5886-01B5-1.Linux.noarch.rpm"
4a) For AIX:
The microcode files will be added to /usr/lib/microcode/.
4b) For Linux:
The microcode files will be added to /lib/firmware/.
4.2 Discovery Tool Microcode CD-ROM creation and download instructions
To obtain information how to burn a
CD-ROM and run the Discovery Tool for an AIX System please go to: http://techsupport.services.ibm.com/server/mdownload/CDROMhelp.html
1) After running the Discovery Tool successfully the "/tmp/microcode/RPM"
directory was created and your rpm files are copied from the CD-ROM.
2) Change to that directory, "cd /tmp/microcode/RPM".
3) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos --force
ses.5886-01B5-1.aix6.1.noarch.rpm
4) Microcode files will be copied to "/etc/microcode". The file
size and checksum of the microcode image will be verified in Section
5.0
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Verifying microcode before download and notes
NOTE: Microcode download must be performed
separately for each "ses" under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
Installation Time: Approximately 30 min System Time.
Please verify the file size and checksum of the raw microcode files
matches the below.
Filesize: 693424
Checksum: 08198
For AIX: "ls -l /usr/lib/microcode/A170027C.01B5" to
verify Filesize.
"sum /usr/lib/microcode/A170027C.01B5"
to verify Checksum.
For Linux: "ls
-l /lib/firmware/IBM-A170027C.01B5"
to
verify Filesize.
"sum /lib/firmware/IBM-A170027C.01B5" to
verify Checksum.
For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SES device in order to update the code. Follow this procedure for each partition:
For AIX:
A) Log into the
target partition.
B) Type: "cd /usr/lib/microcode"
C) FTP (for AIX)
or SFTP (for Linux) to the partition
that has the media bay assigned. (ie. ftp/sftp partition1.ibm.com)
D) Type: "cd /usr/lib/microcode"
E) If using FTP
then Type: "bin"
F) Type: "get A170027C.01B5"
G) Type: "quit"
For Linux:
A) Log into the
target partition.
B) Type: "cd
/lib/firmware"
C) SFTP to the
partition
that has the media bay assigned. (ie. "sftp partition1.ibm.com")
D) Type: "cd /lib/firmware"
E) Type: "get IBM-A170027C.01B5"
F) Type: "quit"
5.1 Microcode Download Procedure-SAS Enclosure Services for FC 5886 for AIX
Procedure:
1) It is advised, but not necessary to stop all applications.
2) Enter diag
3) Select the "Task Selection" from diagnostics menu.
4) Select "Download Microcode" or "Microcode Tasks -> Download
Microcode" from "Task Selection"
menu.
5) Select all of the SAS Enclosure Services for FC 5886s
that need to be updated from the list of devices by pressing "Enter".
The devices will be displayed as ses#, where # is the number of
the device. Press "F7".
6) A dialogue box will be displayed on screen. Press "Enter" to
continue.
7) Select "/usr/lib/microcode".
8) A dialogue box will may be displayed on screen. It will state
that
the current microcode level on the adapter is not in the
/usr/lib/microcode
directory. This is acceptable as you will be flashing new
microcode
onto the adapter. Also, incorrect code will automatically be
rejected. Press "Enter" to continue.
9) An "M" will be displayed next to the latest level of microcode in
the /usr/lib/microcode directory. Select that level and press
"Enter".
10) The following message
will
appear on the screen when download is completed: "Microcode download
complete successfully. The current microcode level for the device
ses# is ..... Please run diagnostics on the adapter to
ensure
that it is functioning properly." DO NOT run
diagnostics on the device at this time.
11) Exit diagnostics.
12) Verify the code level is 01B5 by typing
"lscfg -vl ses#" for each SES device updated. <Where
# is
the number ses device>
5.2
Microcode Download Procedure-SAS Enclosure Services for FC 5886 for
Linux
Procedure:
1) Stop all applications.
2) Type "iprconfig" and press "Enter".
3) Select "Download Microcode" and press "Enter".
4) Select all of the SAS Enclosure Services for FC 5886s
that need to be updated from the list of devices by pressing "1". Then
press "Enter".
5) Select the appropriate microcode image to flash by pressing
"1".
(The image will end in 01B5). Press Enter. Press Enter
again to
confirm.
6) If multiple devices were selected in step 4, then repeat step 5
until finished.
6.0
Microcode Readme Change History
2011-10-16 | -Added 01B5 Microcode level |
2009-09-30 | -Added 0197 Microcode level |
2008-04-07 |
-Modified title of Section 6.0 to Microcode Readme Change History -Modified AIX Support Level requirements. AIX 5.2 TL_11 does not exist and thus was removed. AIX 6.1 was added. |
2008-03-12 | Section 3.0 Corrected to reference "ROM" level instead of "ROS" level |