Microcode Update for SAV-IP
10K.2 73/146 GB
SAS Hard Disk Drive
Microcode Level BF11
DATE: September 15, 2010
Table of Contents
2. AIX and VIOS (PowerVM Virtual I/O Server) Operating System
2.2 Determine Drive Model,
FRU&PN and Current Microcode Level
2.2.2 SCSI Drives attached to PCI SCSI RAID
Controllers
2.3 Transferring and Unpacking
the Microcode Update Package
2.3.1 Internet AIX self
extracting file (.bin)
2.4 Microcode Download
Procedure
2.4.1 SCSI Drives Attached to
SCSI Adapter
2.4.2 SCSI Drives Attached to
PCI RAID Adapter
3.1 Linux 2.6 kernel(such as SuSE SLES 9 or RHEL
4)
===============================================================
The Microcode files provided in this package are for SAS disk
drives used in
with AIX or Linux operating systems
Below
is the list of microcode files in this package:
NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction
Size
Disk Drive Model
FRU# P/N (VPD) Microcode File Name Checksum
--------
--------------------- ----------- ------------- ---------------------------------- ----------
73GB ST973402SS 42R8391 42R5660 ST97340.A1700D14.42463131 42366
146GB ST9146802SS 42R8392 42R5661 ST91468.A1700D14.42463131 42366
Release date |
Code level |
Change Description |
September 2010 |
BF11 |
Fixed the following microcode bug: In
rare situations when drive is left idle for extended period of time, it could
damage the media |
June 15, 2009 |
BF10 |
NOTE: You must install this code if you are planning to update
your SAS adapter code to level 032x0059 or above. Fixed the following code problem: In a
multi-initiator environment (HA, failover), in rare situations, drive(s) that
are part of a Raid Array may go offline if the primary initiator fails during
a command execution, causing the Array to go exposed. |
May 2009 |
BF0F |
Problem Fixed: For the part numbers listed above, an undetected loss of data can occur
if drive experiences mechanical servo problem. The probability of this happening is low, but the code update
should be applied to prevent the event from occurring |
December 2008 |
BF0E |
Problem Fixed: For the part numbers listed above, an
undetected loss of data can occur. The
probability of this happening is low, but
the code update should be applied to prevent the event from occurring |
October 2008 |
BF0C |
General fixes and
enhancements. Also fixed the following
problem: In rare situation, when drive is active |
May 2008 |
BF08 |
Initial Release For System
P Servers |
===============================================================
Note:
For VIOS systems, microcode of shared physical I/O resources can only be
updated from VIOS partition.
To
update disk drive microcode, from VIOS partition, enter the following
command:
oem_setup_env
Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code.
Approximately
20 minutes if using Diagnostics CD; Approximately 5
minutes/drive using AIX concurrent diagnostics.
2.2 Determine Drive Model, FRU&PN and
Current Microcode Level
To see the drive type and current
microcode level, Execute the following command:
lscfg -vl hdisk* |pg ; For
drives NOT configured for RAID
lscfg –vl pdisk* |pg ; For
drives configured for RAID
DEVICE LOCATION DESCRIPTION
Hdisk1 U8844.3CZ.23A0187-P1-T11-L1-L0 SCSI Disk Drive
(73400 MB)
Manufacturer................
Machine
Type and Model......ST973402SS
FRU
Number.................. 42R8391
Serial
Number...............3LB04G5T
EC
Level....................H17923E
Part
Number................. 42R5660
Device
Specific.(Z0)........000005129F00100A
Device Specific.(Z1)........0714BF11
Device
Specific.(Z2)........1000
Device
Specific.(Z3)........05124
Device
Specific.(Z4)........0001
Device
Specific.(Z5)........22
Device
Specific.(Z6)........H17923E
If the data returned in the “Part Number”, “FRU Number”, and
“Machine Type and Model” fields
match the one listed in section 1.1
Note:
Drive microcode level in “
===============================================================
2.3 Transferring and Unpacking the Microcode Update Package
a) Make a directory on an AIX
system to receive the AIX format file.
Enter: mkdir
/tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate
directory (using "Save as ...").
You'll see the filename is SAV-IP10K2.bin
c) Unpack the file by executing the instructions below.
Enter the commands:
cd /tmp/fwupdate
chmod +x SAV-IP10K2.bin
./SAV-IP10K2.bin
[Don't overlook the periods (.) in the above command.]
The directory SAV-IP10K2 with microcode files
listed in section 1.1 will be added to /tmp/fwupdate.
d-Enter the following command to copy the
microcode files to " /etc/microcode "
directory :
cp /tmp/fwupdate/
SAV-IP10K2/ST9* /etc/microcode
e- If
transferring files to a different system using floppy diskettes, use the
following procedure to copy files to diskette
Note: Don't overlook the complete path of microcode files, AIX Diag microcode download
will not
work if files are not copied with complete path onto the diskette.
Enter
the following command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename | backup -ivf /dev/rfd0
where microcodefilename is microcode file that
is needed, for example:
ls /etc/microcode/ ST97340.A1700D14.42463131
| backup -ivf
/dev/rfd0
Note: The
instructions that follow are specific AIX commands. AIX commands are CASE
(lower and upper) SENSITIVE,
and must be entered exactly as shown, including
filenames.
a)
Make a directory on an AIX system to receive the
Enter: mkdir
/tmp/microcode
b)
Transfer the
You'll see the filename is SAV-IP10K2–BF11-AIX.rpm
c) Unpack
the file by executing the instructions below:
Enter the commands:
rpm -ihv
--ignoreos
--force SAV-IP10K2–BF11-AIX.rpm ;(please note, there are two dashes)
The
file size and checksum will be verified.
The
microcode files will be added to /etc/microcode/
Copy
microcode updates from the CD-ROM to standard locations on your local disk:
1.
2. Microcode files will be copied to /usr/lib/microcode
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated directory
or file then the user will be prompted for a new location.
========================================================
Warning: Do not power off the system or the drive during microcode download as
this may permanently damage the disk drive
NOTE: Please save current and older versions of the microcode update files in
case you need to restore your system.
Caution: The microcode download process is nondestructive to the hard disks;
however, as a precaution, ensure that a backup operation has been performed on
the affected systems PRIOR to the microcode installation.
Can microcode be installed Concurrently? YES
Is system reboot needed to activate the
microcode: Yes if stand alone diagnostics CD is used, NO if concurrent
diagnostics is used.
Installation Time: Approximately 20 minutes/drive if stand alone
diagnostics is used(using Diagnostics CD); Approximately
5 minutes/drive if concurrent diagnostics is used.
2.4.1.2.1 Concurrent
Download
1.
Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then
press "F7" to commit..
5- A small screen displays the message " *** NOTICE***
The microcode installation occurs while the attached drives are available
for use..... "
Press enter to continue
6. Select the source for microcode, use arrow key to go up/down, Enter to continue.
/etc/microcode
diskette
- Use /etc/microcode
if "restore" command is used to copy files from diskette onto the
disk
- Use diskette if using diskette as the source for download
NOTE: A prompt will ask you to insert the
microcode diskette in diskette drive(if Diskette is
selected above). Insert the diskette and press ENTER
7- Display shows a list of microcodes
available for the selected drive, highlight option "M
ST9xx...", the latest microcode for the drive and press ENTER. A
message may warn you that current level of microcode is not available on the
media, press ENTER to continue.
8. You will receive a msg. "Current
Microcode is...." and "Download has completed successfully"
(this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).
2.4.1.2.2 Standalone (Service Mode) Download
This procedure is
used for all drives including rootvg or paging space
drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above; It is
recommended to use the same level
of Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
(The current microcode
level of the resource you selected earlier will be displayed at the top of the
screen)
7. Make the following selections on the next screen:
Select Input Device
--------------------------------------- [ diskette]
Microcode level to download
-----------------------------[ latest]
Download latest level even if
-----------------------------[ yes]
current is missing
NOTE: A prompt will ask you to insert the
microcode diskette into the floppy drive. Insert the diskette which
accompanies these instructions. If this level is already installed in the drive
you've selected a message will let you know. A message also may come up to let
you know that the Diskette(or Disk) does not have the
previous level microcode file. This is true and is not required to complete the
download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode
is...." and "Download has completed successfully"
(this may take a
few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard
disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.
======================================================
Microcode can be
updated using the iprconfig utility. The iprconfig utility
allows for multiple levels of adapter and device
microcode to exist on the
system at the same time. After the device to
update microcode is
selected, all available microcode levels are
presented to choose to download.
1.
a) If using
SLES 9 base, install the package by typing:
rpm -ivh --ignoreos SAV-IP10K2–BF11-AIX.rpm
b) If using SLES 9 SP1 or better or RHEL 4 or better, install the
package by typing:
rpm -ivh SAV-IP10K2–BF11-LINUX.rpm
2. Update the
microcode by typing:
iprconfig
Press Enter.
3. Select
Download microcode and press Enter.
4. Select the
device you wish to update by typing a 1 then pressing Enter. Multiple devices
may be selected.
5. Select the
microcode image to be downloaded to the device by typing a 1 then pressing
Enter.
6. Press Enter again
to confirm the download (display shows “Microcode Download in
Progress” with elapsed time)
7. If multiple
devices were selected, repeat from Step 5 for the next device.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display hardware status" option.
3. Select disk
to query by typing a 1 next to it and pressing "Enter"
4. Look at the
"Firmware Version" field
--------------------------------------------------------------------------
Microcode can be
updated using the iprupdate utility. If iprupdate finds newer
microcode on the system it will be downloaded to the
disk.
1. Install the
package by typing:
rpm -ivh --ignoreos SAV-IP10K2–BF11-AIX.rpm
Press Enter.
2. Update the
microcode by typing:
iprupdate
Press Enter.
To check the
microcode level:
1. Start iprconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the disk
you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the
"Firmware Version" field
-------------------------------------------------------------------------
Microcode can be
updated using the sisupdate utility. If sisupdate finds newer
microcode on the system it will be downloaded to the
disk.
1. Install the
package by typing:
rpm -ivh --ignoreos SAV-IP10K2–BF11-AIX.rpm
Press Enter.
2. Update the
microcode by typing:
sisupdate
Press Enter.
To check the
microcode level:
1. Start sisconfig utility,
2. Select
"Display disk hardware status" option.
3. Find the disk
you wish to query and note its serial number.
4. Type
"d" to get to the "Display disk unit details" screen.
5. Select disk
to query by typing a 5 next to it and pressing "Enter"
6. Look at the "Firmware
Version" field