IBM eServer
PCI-X266 Ext Dual-x4 3Gb SAS Adapter (CCIN 572A)
PCI-X266 Ext Dual-x4 3Gb SAS RAID Adapter (CCIN 572B)
PCI-X266 Planar 3Gb SAS Adapter (CCIN 572C)
PCI-X266 Planar 3Gb SAS RAID Adapter (CCIN 57B8)
DATE: July 15, 2008
Table of Contents
2.0 General Information
2.1 Installation Time
2.2 Machine's Affected
2.3 AIX Requirements
2.4 Linux Requirements
3.0 Determine the Current Microcode Level for AIX
3.1 Determine the Current Microcode Level for
Linux
4.0 Downloading
and Unpacking the Firmware Update
Package from CORE
4.1 Downloading the RPM Format File to the Target
Server
4.2 Discovery Tool Microcode CD-ROM creation and download
instructions
5.0 Verifying microcode before download and notes
5.1 Microcode Download Procedure-572A, 572C, 57B8 SAS Adapters for AIX
5.2 Microcode Download Procedure-572A, 572C, 57B8 SAS
Adapters for Linux
6.0 Microcode Readme Change History
=====================================================================================
02200059 | -Fix for 572B in Dual Controller mode. The adapter will no longer log a 9076 error on a boot, if the system contains 572B's that have no FC 5886 SAS drawers attached. |
02200056 |
-CCIN 572A & 57B9 enhancement to add 2 extra retries upon configuration. This modification was made to more reliably configure split backplane configurations without AIX reporting errors. For these split backplane configurations, please install this code along w/ 9117-MMA SES microcode level 0021 or 8204-E8A/8203-E4A SES microcode level 0008 -Various Target Mode/Dual Controller enhancements. |
02200050 |
-GA Level for 572B -This microcode level fixes a potential undetected loss of data that was discovered in test between CCIN 572A and DAT72 SAS tape drive (FC 1400 or 5907). There have been no reported cases of this occurring in the field and the chance of occurrence is extremely small - near 0. |
0220004a | Fix for TEMP SISSAS_ERR11T logged against CCIN 57B7 during boot or other configuration time. That error decoded further as a REASON FOR FAILURE Timeout - op started. A microcode update to 57B8 addresses the issue. It is best practice to apply the update to 57B7 when updating 57B8. |
0220003c | Various Unit Check condition fixes (04448400 and 04448200 errors) |
02200039 | GA Level for CCIN 57B8. |
02200035 | GA Level for CCIN 572A, 572C on 7998-61X |
01200041 | -Data error fix for Low probability condition. If data loss is discovered on two devices at very close intervals, it was possible that the indication of this condition could have been lost on device 2 during device 1's recovery. |
0120003b |
-Numerous functional enhancements to prevent adapter error and Unit
Check Conditions. Unit Checks require an adapter reset to recover. -Fix for error logged during AIX concurrent maintenance when DVD drive is removed and not replaced. |
01200037 | GA Level for CCIN 572C |
This subject microcode is to be used
on the following SAS Adapter/controller types:
CCIN 572A: PCI-X266 Ext Dual-x4 3Gb SAS Adapter
CCIN 572B: PCI-X266 Ext Dual-x4 3Gb SAS
RAID Adapter
CCIN 572C: PCI-X266 Planar 3Gb SAS Adapter
CCIN 57B8: PCI-X266 Planar 3Gb SAS RAID Adapter
2.1
Installation Time:
Approximately 30 minutes
2.2
Machine's Affected:
572A
7311-D11, D20
7314-G30
8203-E4A
8204-E8A
9117-MMA
9119-FHA
9125-F2A
572B
7311-D11, D20
7314-G30
8203-E4A
8204-E8A
9117-MMA
9119-FHA
9125-F2A
572C
9117-MMA
7998-61X
8204-E8A
8203-E4A
9125-F2A
57B8
8204-E8A
8203-E4A
2.3
AIX Requirements:
For support of 572A:
AIX 5.3 TL_06 w/ SP4 (Sevice Pack 4), AIX 5.3 TL_07, AIX 6.1 or above
For support of 572B:
AIX 5.3 TL_08, AIX 6.1 TL_01 or above
For support of 572C:
AIX 5.2 TL_10 or above, AIX 5.3 TL_06, AIX 6.1 or above
For support of 57B8:
AIX 5.3 TL_06 w/ SP4 (Sevice Pack 4), AIX 5.3 TL_07, AIX 6.1 or above
For support of 572A:
SUSE Linux Enterprise Server 10-SP1
for POWER or above
Red Hat Enterprise Linux AS for POWER Version 4 Update 6, RHEL 5 Update 1 or above
For support of 572B:
SUSE Linux Enterprise Server 10-SP2
for POWER or above
Red Hat Enterprise Linux AS for POWER Version 4 Update 7, RHEL 5 Update 2 or above
For support of 572C:
SUSE Linux Enterprise Server 10 for
POWER or above
Red Hat Enterprise Linux AS for POWER Version 4 Update 4 or above
For support of 57B8:
SUSE Linux Enterprise Server 10-SP1
for POWER or above
Red Hat Enterprise Linux AS for POWER Version 4 Update 6, RHEL 5 Update 1 or above
3.0 Determine the Current Microcode Level for AIX:
Before you install the microcode, it is important to determine the microcode level of the Adapter installed in the target system. Use
the following instructions to read the ROM level stored in the Adapter's VPD.
1) List the SAS RAID Adapters installed in the system by typing:
lsdev -C | grep sissas
Note: All of the SAS RAID initiators addresses that are installed will be displayed. The names will be sissasX, where X is 0, 1, etc.
2) To check the current microcode level for the adapter or controller enter the following command
lscfg -vl sissasX
Where X is the number/s of the previous command. The Command will produce output similar to
For 572A
DEVICE LOCATION DESCRIPTION
sissas0 U78A0.001.DNWFZZT-P1-C4-T1 PCI-X266 Ext Dual-x4 3Gb SAS Adapter
PCI-X266 Ext Dual-x4 3Gb SAS Adapter :
Part Number.................42R7989
FRU Number..................42R7989
Serial Number...............YL3027138706
Manufacture ID..............0002
EC Level....................0
ROM Level.(alterable).......02200026
Customer Card ID Number.....572A
Product Specific.(Z1).......1
Hardware Location Code......U78A0.001.DNWFZZT-P1-C4-T1
If the ROM Level is less than 02200059 then you should update the microcode.
For 572C
DEVICE LOCATION DESCRIPTION
sissas2
U789D.001.DQDTTPM-P1-T3 PCI-X266 Planar 3Gb SAS Adapter
ROM Level.(alterable).......01200036
Customer Card ID Number.....572C
Device Specific.(YL)........U789D.001.DQDTTPM-P1-T3
If the ROM Level is less than 02200059 then you should update the microcode.
For 57B8
DEVICE LOCATION DESCRIPTION
sissas0
U78A0.001.DNWFZYA-P1-T9 PCI-X266 Planar 3Gb SAS RAID Adapter
ROM Level.(alterable).......02200026
Customer Card ID Number.....57B8
Device Specific.(YL)........U78A0.001.DNWFZYA-P1-T9
If the ROM Level is less than 02200059 then you should update the microcode.
3.1
Determine the Current Microcode Level for Linux:
1) Type "iprconfig"
2) Select "Display hardware status"
3) Select SAS adapter by typing a "1" in front of it and pressing
Enter.
4) The Command will
produce output similar to
"Firmware Version . . . . . . . .
. . . . : 02200035"
If the Firmware Version is less
than 02200059 then you should update the microcode.
4.0 Downloading and Unpacking the Firmware Update Package from CORE
NOTE: The CORE image will now be the RPM Format File.4.1 Downloading the RPM Format File
to the Target Server
Use this
method to download to an AIX or Linux system:
Note: The instructions that follow are specific AIX/Linux commands. AIX/Linux commands are CASE (lower and upper) SENSITIVE, and must be entered exactly as shown, including filenames.
1) Make a directory on an AIX/Linux system to receive the RPM format file.
Enter: "mkdir /tmp/microcode"
Enter: "mkdir /tmp/microcode/RPM"
2) Transfer the
RPM format file to the /tmp/microcode/RPM directory (using "Save as ...").
Change to that directory, "cd /tmp/microcode/RPM".
You'll see the
filenames for the RPM files.
A) For AIX:
The filename is pci.101402BD.20-02200059-1.aix5.1.noarch.rpm
B) For
Linux: The filename is
pci.101402BD.20-02200059-1.Linux.noarch.rpm
3) Unpack the file by executing the instructions
below:
A) For AIX:
Type "rpm -ihv --ignoreos --force
pci.101402BD.20-02200059-1.aix5.1.noarch.rpm"
B) For Linux:
Type "rpm -ihv --ignoreos --force
pci.101402BD.20-02200059-1.Linux.noarch.rpm"
4a) For AIX:
The microcode files will be added to /usr/lib/microcode/.
4b) For Linux:
The microcode files will be added to /lib/firmware/.
4.2 Discovery Tool Microcode CD-ROM creation and download instructions
To obtain information how to burn a
CD-ROM and run the Discovery Tool for an AIX System please go to: http://techsupport.services.ibm.com/server/mdownload/CDROMhelp.html
1) After running the Discovery Tool successfully the "/tmp/microcode/RPM"
directory was created and your rpm files are copied from the CD-ROM.
2) Change to that directory, "cd /tmp/microcode/RPM".
3) Unpack the file by executing the instructions below:
Enter the commands:
rpm -ihv --ignoreos --force
pci.101402BD.20-02200059-1.aix5.1.noarch.rpm
4) Microcode files will be copied to "/etc/microcode". The file
size and checksum of the microcode image will be verified in Section
5.0
Notes:
- "/etc/microcode" is a symbolic link to "/usr/lib/microcode".
- If permission does not allow the copy to the above stated
directory
or file then the user will be prompted for a new location.
5.0 Verifying microcode before download and notes
NOTE: Microcode download must be performed
separately for each Adapter bus under distinct Logical Partitions
(LPAR's).
Please save current and older versions of the microcode update files in
case you need to restore your system.
NOTE: Microcode Download CAN be performed concurrently.
Installation Time: Approximately 30 min System Time.
Please verify the file size and checksum of the raw microcode files
matches the below.
Filesize: 1249248
Checksum: 33825
For AIX: "ls -l /usr/lib/microcode/53495320.02200059" to
verify Filesize.
"sum /usr/lib/microcode/53495320.02200059"
to verify Checksum.
For Linux: "ls
-l /lib/firmware/pci.101402BD.20.02200059"
to
verify Filesize.
"sum /lib/firmware/pci.101402BD.20.02200059" to
verify Checksum.
For systems that have LPAR installed, the microcode file must be placed on all partitions that have a SAS device in order to update the code. Follow this procedure for each partition:
For AIX:
A) Log into the
target partition.
B) Type: "cd /usr/lib/microcode"
C) FTP (for AIX)
or SFTP (for Linux) to the partition
that has the media bay assigned. (ie. ftp/sftp partition1.ibm.com)
D) Type: "cd /usr/lib/microcode"
E) If using FTP
then Type: "bin"
F) Type: "get 53495320.02200059"
G) Type: "quit"
For Linux:
A) Log into the
target partition.
B) Type: "cd
/lib/firmware"
C) SFTP to the
partition
that has the media bay assigned. (ie. "sftp partition1.ibm.com")
D) Type: "cd /lib/firmware"
E) Type: "get pci.101402BD.20.02200059"
F) Type: "quit"
5.1 Microcode Download Procedure-572A, 572C, 57B8 SAS Adapters for AIX
Procedure:
1) It is advised, but not necessary to stop all applications.
2) Enter diag
3) Select the "Task Selection" from diagnostics menu.
4) Select "Download Microcode" or "Microcode Tasks -> Download
Microcode" from "Task Selection"
menu.
5) Select all of the SAS Adapters/Controllers
that need to be updated from the list of devices by pressing "Enter".
The devices will be displayed as sissas#, where # is the number of
the device. Press "F7".
6) A dialogue box will be displayed on screen. Press "Enter" to
continue.
7) Select "/usr/lib/microcode".
8) A dialogue box will may be displayed on screen. It will state
that
the current microcode level on the adapter is not in the
/usr/lib/microcode
directory. This is acceptable as you will be flashing new
microcode
onto the adapter. Also, incorrect code will automatically be
rejected. Press "Enter" to continue.
9) An "M" will be displayed next to the latest level of microcode in
the /usr/lib/microcode directory. Select that level and press
"Enter".
10) The following message
will
appear on the screen when download is completed: "Microcode download
complete successfully. The current microcode level for the device
sissas# is ..... Please run diagnostics on the adapter to
ensure
that it is functioning properly." DO NOT run
diagnostics on the device at this time.
11) Exit diagnostics.
12) Verify the code level is 02200059 by typing
"lscfg -vl sissas#" for each SAS device updated. <Where
# is
the number sissas device>
5.2
Microcode Download Procedure-572A, 572C, 57B8 SAS Adapters for
Linux
Procedure:
1) Stop all applications.
2) Type "iprconfig" and press "Enter".
3) Select "Download Microcode" and press "Enter".
4) Select all of the SAS Adapters/Controllers
that need to be updated from the list of devices by pressing "1". Then
press "Enter".
5) Select the appropriate microcode image to flash by pressing
"1".
(The image will end in 02200059). Press Enter. Press Enter
again to
confirm.
6) If multiple devices were selected in step 4, then repeat step 5
until finished.
6.0
Microcode Readme Change History
2008-07-15 | -Microcode Level 02220059 added |
2008-06-04 | -Microcode Level 02220056 added |
2008-04-30 |
-Microcode Level 02200050 added -Added 572B SAS RAID Adapter -Corrected Section 2.4 RHEL Minimum requirements for 572A, 57B8 -Added new MTM's to Section 2.2 Machine's Affected |
2008-04-07 |
-Added 57B8 SAS RAID Enablement Card to the title of the readme -Modified Section 2.3 AIX Support Level requirements. AIX 5.2 TL_11 does not exist and thus was removed. AIX 6.1 was added. |